UP
DN
OPEN OFFICE
RECEPT.
WOMEN LOCKER
WOMEN
MECHANICAL
ELECTRICAL
JAN
SHOWERS
STORAGE
CORR.
C101
ELEV.
E1
MACHINE
CORR.
C104
CORR.
C102
IND. PRACTICE
ROOMS
CORR.
C110 STORAGE
STORAGE
GROUP
REHEARSAL 1
CORR.
C105
MECHANICAL /
ELECTRICAL
GROUP
REHEARSAL 2
GROUP
REHEARSAL 3
GROUP
REHEARSAL 4
STG
CORR.
C107
INSTRUMENT
MAINTENANCE
MECH / ELECT
SPRINKLER
INSTRUMENT
STORAGE
CORR.
C108
MENS
MEN SHOWER
MEN LOCKER
SUPPLY OFFICE
COMM.
CORR.
C109
CORR.
C106
FLOOR FINISHES
CPT-1
CPT-2
CTF-1
EXC
LVT-1
VCT-1
VCT-2
VCT-1
PT-1
RB-1
PT-3
VCT-2
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-5
RB-1
PT-5
VCT-1
PT-1
RB-1
PT-3
CTF-1
PT-5 / CTW-1
CTW-1
PT-5
CTF-1
PT-5 / CTW-1
CTW-1
PT-5
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
CPT-1
PT-1
RB-1
PT-3
CPT-1
PT-1
RB-1
PT-3
CPT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
CPT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
CTF-1
PT-5 / CTW-1
CTW-1
PT-5
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-5
RB-1
PT-5
CTF-1
PT-5 / CTW-1
CTB-1
PT-5
VCT-1
PT-1
RB-1
PT-3
CPT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3VCT-1
PT-1
RB-1
PT-3
2 22
2 2 2
VCT-1
PT-1
RB-1
PT-3
VCT-1
PT-1
RB-1
PT-3
CORR.
C103
SIGNAGE GENERAL NOTES
1. ALL SIGNAGE SHALL COMPLY WITH JBSA INSTALLATION DESIGN GUIDE &
UFC 3-120-01 DESIGN: SIGN STANDARDS.
2. ALL SIGNAGE LOCATIONS SHOWN ARE APPROXIMATE. INSTALLER TO
LOCATE AS NECESSARY TO ACCOMMODATE ARCHITECTURAL ELEMENTS,
ELECTRICAL SWITCHES, DATA OUTLETS, ETC.
3. ALL INTERIOR SIGNS SHALL HAVE BRAILLE LETTERING.
4. ALL SIGNAGE LOCATION SHOWN IS APPROXIMATE. INSTALLER TO LOCATE
AS NECESSARY TO ACCOMMODATE ARCHITECTURAL ELEMENTS,
ELECTRICAL SWITCHES, DATA OUTLETS, ETC.
5. REF TO SHEET I-531 FOR SIGNAGE TYPE DETAILS.
6. REFER SIGNAGE SCHEDULE FOR ROOM SIGN TYPE AND TEXT UNLESS
OTHERWISE NOTED.
7. EACH WORKSTATION TO RECEIVE SIGN TYPE 1A.
SIGNAGE LEGEND
SIGN TYPEXX
FINISH PLAN NOTES
PROVIDE AT ALL EXTERIOR WINDOWS.
SS1
WT1
*REFER TO FINISH SCHEDULE FOR TYPICAL
FLOOR TRANSITIONS
FLOOR FINISH SYMBOL:
FINISH LISTED DENOTES
PRIMARY ROOM FINISH,
UNO
CEILING
WALL
BASE
FLOOR
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F O
R T
S A
M H
O U
S T
O N
T
E X
A S
I-101
F
IN
IS
H
P L A
N
F
IR
S T
F L O
O R
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F
O R
T S
A M
H O
U S
T O
N T
X
K E
N A
L L
F N
I S
A V
O Y
D R
IV
E
S
U
IT
E
H O
U S
T O
N T
E X
A S
P H
O N
E (8
-8
S L A
A R
C H
IT
E
C T
S
J D
IX
O
N
C H
O P
K
IN
S
A U
G U
S T
W G
B
FINAL SUBMITTAL
1/8" = 1'-0"I-101
A1 FINISH PLAN - FIRST FLOOR
AUGUST 12, 2019
0' 8' 16'
GRAPHIC SCALE 1/8" = 1'-0"
4'
NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
MECHANICAL /
ELECTRICAL
BREAK /
CONFERENCE
ADMIN.
COMMANDER
1SG
OPERATIONS
MEN
WOMEN
CORR.
C206
CORR.
C204
E L E
C
STORAGE
C O
R R
C
CORR.
C202
MECHANICAL
ROCK
REHEARSAL
OPEN OFFICE
COMM
JAN.
STOR
STOR
MECHANICAL
STORAGE
PERFORMANCE /
REHEARSAL HALL
MECHANICAL
FLOOR FINISHES
CPT-1
CPT-2
CTF-1
EXC
LVT-1
VCT-1
VCT-2
WT-2
W T
-2 W
T -2
W T
-2
WT-2 WT-2 WT-2 WT-2 WT-2 WT-2
CPT-1
PT-1
WD-2
VARIES
CPT-1
PT-1
WD-2
ACT-1
CPT-1
PT-1
WD-2
ACT-1
CPT-1
PT-1
WD-2
ACT-1
CPT-1
PT-1
WD-2
ACT-1
CTF-1
PT-5 / CTW-1
CTW-1
PT-5
LVT-1
PT-1
WD-2
ACT-1
LVT-1
PT-1
WD-2
ACT-1
LVT-1
PT-1
RB-1
PT-3
LVT-1
PT-1
RB-1
PT-3
CTF-1
PT-5 / CTW-1
CTW-1
PT-5
LVT-1
PT-1
RB-1
PT-3
LVT-1
PT-1
WD-2
ACT-1
LVT-1
PT-1
WD-2
ACT-1
LVT-1
PT-1
RB-1
ACT-1
LVT-1
PT-1
WD-2
ACT-1
CPT-1
PT-1
WD-2
VARIES
VCT-1
PT-1
RB-1
PT-3
VCT-2
PT-1
RB-1
ACT-1
CPT-2
WDW-1 / PT-1
WD-1
VARIES
VCT-1
PT-1
RB-1
ACT-1
VCT-1
PT-1
RB-1
PT-3
6 6 6
CORR.
C205
VEST.
CPT-2
WDW-1 / PT-1
WD-1
ACT-1
LVT-1
PT-1
WD-2
PT-3
CORR.
C203
LVT-1
PT-1
WD-2
ACT-1
SIGNAGE GENERAL NOTES
1. ALL SIGNAGE SHALL COMPLY WITH JBSA INSTALLATION DESIGN GUIDE &
UFC 3-120-01 DESIGN: SIGN STANDARDS.
2. ALL SIGNAGE LOCATIONS SHOWN ARE APPROXIMATE. INSTALLER TO
LOCATE AS NECESSARY TO ACCOMMODATE ARCHITECTURAL ELEMENTS,
ELECTRICAL SWITCHES, DATA OUTLETS, ETC.
3. ALL INTERIOR SIGNS SHALL HAVE BRAILLE LETTERING.
4. ALL SIGNAGE LOCATION SHOWN IS APPROXIMATE. INSTALLER TO LOCATE
AS NECESSARY TO ACCOMMODATE ARCHITECTURAL ELEMENTS,
ELECTRICAL SWITCHES, DATA OUTLETS, ETC.
5. REF TO SHEET I-531 FOR SIGNAGE TYPE DETAILS.
6. REFER SIGNAGE SCHEDULE FOR ROOM SIGN TYPE AND TEXT UNLESS
OTHERWISE NOTED.
7. EACH WORKSTATION TO RECEIVE SIGN TYPE 1A.
SIGNAGE LEGEND
SIGN TYPEXX
FINISH PLAN NOTES
PROVIDE AT ALL EXTERIOR WINDOWS.
SS1
WT1
*REFER TO FINISH SCHEDULE FOR TYPICAL
FLOOR TRANSITIONS
FLOOR FINISH SYMBOL:
FINISH LISTED DENOTES
PRIMARY ROOM FINISH,
UNO
CEILING
WALL
BASE
FLOOR
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F O
R T
S A
M H
O U
S T
O N
T
E X
A S
I-102
F
IN
IS
H
P L A
N
S E
C O
N D
F L O
O R
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F
O R
T S
A M
H O
U S
T O
N T
X
K E
N A
L L
F N
I S
A V
O Y
D R
IV
E
S
U
IT
E
H O
U S
T O
N T
E X
A S
P H
O N
E (8
-8
S L A
A R
C H
IT
E
C T
S
J D
IX
O
N
C H
O P
K
IN
S
A U
G U
S T
W G
B
FINAL SUBMITTAL
AUGUST 12, 2019
0' 8' 16'
GRAPHIC SCALE 1/8" = 1'-0"
4'
NORTH
1/8" = 1'-0"I-102
A1 FINISH PLAN - SECOND FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A
ADA PLAQUE STYLE
SIGN W/ RAISED
BRAILLE, GRAPHICS
AND 1" TEXT
9"
NOTE: ALL ADA
SIGNAGE SHOULD
COMPLY WITH
CHAPTER 7 OF THE
ADA GUIDELINES
FOR MOUNTING,
LETTERING, AND
DESIGN.
SLIDE SLOT
SLIDE OUT SLOTS FOR
CHANGEABLE NAME
PLATES
ADA PLAQUE STYLE
SIGN W/ RAISED
BRAILLE, GRAPHICS
AND 1" TEXT
9"
NOTE: ALL ADA
SIGNAGE SHOULD
COMPLY WITH
CHAPTER 7 OF THE
ADA GUIDELINES
FOR MOUNTING,
LETTERING, AND
DESIGN.
PANTRY
WORKSTATION NUMBER
9"
NOTE: HOOK AND
LOOP VELCRO
MOUNTED
SLIDE SLOT
SLIDE OUT SLOTS FOR
CHANGEABLE NAME
PLATES
ADA PLAQUE STYLE
SIGN W/ RAISED
BRAILLE, GRAPHICS
AND 1" TEXT
9"
NOTE: ALL ADA
SIGNAGE SHOULD
COMPLY WITH
CHAPTER 7 OF THE
ADA GUIDELINES
FOR MOUNTING,
LETTERING, AND
DESIGN.
MEN
ADA PLAQUE STYLE
SIGN W/ RAISED
BRAILLE, GRAPHICS
AND 1" TEXT
9"
NOTE: ALL ADA
SIGNAGE SHOULD
COMPLY WITH
CHAPTER 7 OF THE
ADA GUIDELINES
FOR MOUNTING,
LETTERING, AND
DESIGN.
WOMEN
ADA PLAQUE STYLE
SIGN W/ RAISED
BRAILLE, GRAPHICS
AND 1" TEXT
9"
NOTE: ALL ADA
SIGNAGE SHOULD
COMPLY WITH
CHAPTER 7 OF THE
ADA GUIDELINES
FOR MOUNTING,
LETTERING, AND
DESIGN.EXIT
ADA PLAQUE STYLE
SIGN W/ RAISED
BRAILLE, GRAPHICS
AND 1" TEXT
9"
" EXIT
NOTE: ALL ADA
SIGNAGE SHOULD
COMPLY WITH
CHAPTER 7 OF THE
ADA GUIDELINES
FOR MOUNTING,
LETTERING, AND
DESIGN.
1'-8"
A S
R E
Q D
T Y
P
COORDINATE EXACT
LOCATIONS AS NECESSARY
TO ACCOMMODATE ARCH.
FEATURES, ELECT & DATA
OUTLETS, SWITCHES ETC.
1/8" THICK ENGRAVING
(ACRYLIC) STOCK
HELVETICA REGULAR TEXT,
BLACK LETTERS AND
NUMBERS ON BACKGROUND,
ROOM LETTERS AND NUMBERS
SHALL BE RAISED 1/32" MIN.
XXXX
XXXX
XXXX
6"
SLIDE SLOT
SLIDE OUT SLOTS FOR
CHANGEABLE
INFORMATIONAL SIGNS
BULLETIN BOARD MESSAGE
DISPLAY CASE 4'-0" H x 5'-0" W x 2" D WITH TWO HINGED
LOCKABLE GLASS DOORS,
ALUMINUM FRAME, CORK
BOARD SURFACE
NOTICES
DISPLAY AREA
5' - 0"
NOTE: ELEVATION SHOWN
BELOW IS FOR MOUNTING
HEIGHT/LOCATION OF SIGNAGE
INFO ONLY. REFER TO USER
GROUP FOR INFO RE: EXACT
LETTERING, ETC.
FINISH FLOOR
NOTICES
DISPLAY AREA
5' - 0"
XXXXXX XXXXXX XXXXXXXXXXXXXXXX XXXXXXXXX
XXXXXX XXXXXX XXXXXXXXXXXXXXXX XXXXXXXXX
XXXXXX XXXXXX XXXXXXXXXXXXXXXX XXXXXXXXX
XXXXXX XXXXXX XXXXXXXXXXXXXXXX XXXXXXXXX
XXX
XXX
XXX
XXX
XXXXXXXXXX
2' - 0"
/2
XXXXXXXXXX
SIGNAGE GENERAL NOTES
1. ALL SIGNAGE SHALL COMPLY WITH JBSA INSTALLATION DESIGN GUIDE &
UFC 3-120-01 DESIGN: SIGN STANDARDS.
2. ALL SIGNAGE LOCATIONS SHOWN ARE APPROXIMATE. INSTALLER TO
LOCATE AS NECESSARY TO ACCOMMODATE ARCHITECTURAL ELEMENTS,
ELECTRICAL SWITCHES, DATA OUTLETS, ETC.
3. ALL INTERIOR SIGNS SHALL HAVE BRAILLE LETTERING.
4. ALL SIGNAGE LOCATION SHOWN IS APPROXIMATE. INSTALLER TO LOCATE
AS NECESSARY TO ACCOMMODATE ARCHITECTURAL ELEMENTS,
ELECTRICAL SWITCHES, DATA OUTLETS, ETC.
5. REF TO SHEET I-531 FOR SIGNAGE TYPE DETAILS.
6. REFER SIGNAGE SCHEDULE FOR ROOM SIGN TYPE AND TEXT UNLESS
OTHERWISE NOTED.
7. EACH WORKSTATION TO RECEIVE SIGN TYPE 1A.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F O
R T
S A
M H
O U
S T
O N
T
E X
A S
I-531
S
IG
N A
G E
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F
O R
T S
A M
H O
U S
T O
N T
X
K E
N A
L L
F N
I S
A V
O Y
D R
IV
E
S
U
IT
E
H O
U S
T O
N T
E X
A S
P H
O N
E (8
-8
S L A
A R
C H
IT
E
C T
S
J D
IX
O
N
C H
O P
K
IN
S
A U
G U
S T
W G
B
FINAL SUBMITTAL
3" = 1'-0"I-531
D1 SIGN TYPE 1
3" = 1'-0"I-531
D3 SIGN TYPE 2
3" = 1'-0"I-531
D2 SIGN TYPE 1A - WORKSTATION
3" = 1'-0"I-531
C1 SIGN TYPE 3
3" = 1'-0"I-531
C2 SIGN TYPE 4
3" = 1'-0"I-531
C3 SIGN TYPE 5
3" = 1'-0"I-531
B1 SIGN TYPE 6
1 1/2" = 1'-0"I-531
B3 SIGN TYPE 8
3" = 1'-0"I-531
B2 SIGN TYPE 7
3/4" = 1'-0"I-531
A1 SIGN TYPE 9 - BULLETIN BD. CASE W/ GLASS DOORS
3/4" = 1'-0"I-531
A3 SIGN TYPE 10 - LOBBY DIRECTORY SIGN
SIGNAGE SCHEDULE
SIGN
DOOR SIGN ROOM
SIGN
TYPE
SIGN
NUMBER SIGN TEXT COMMENTS
101 OPEN OFFICE 2 101 OFFICE
101A OPEN OFFICE 6 - EXIT
102 RECEPT. 2 102 RECEPT
103 JAN 2 103 JAN
105 WOMEN
LOCKER
4 - WOMEN
LOCKER
107 STORAGE 2 107 STORAGE
111 MECHANICAL /
ELECTRICAL
2 111 MECHANICAL /
ELECRICAL
112 GROUP
REHEARSAL 2
2 112 GROUP
REHEARSAL 2
113 MEN 3 - MEN
113 GROUP
REHEARSAL 3
2 113 GROUP
REHEARSAL 3
114 WOMEN 4 - WOMEN
114 GROUP
REHEARSAL 4
2 114 GROUP
REHEARSAL 4
115 STG 2 115 STORAGE
116 INTRUMENT
MAINTENANCE
2 116 INSTRUMENT
MSINTENANCE
117 MECH / ELECT 2 117 MECH / ELECT
117A MECH / ELECT 6 - EXIT
119 INSTRUMENT
STORAGE
2 119 STORAGE
120 MENS 3 - MEN
121 MEN SHOWER 2 - SHOWER
123 GROUP
REHEARSAL 1
2 123 GROUP
REHEARSAL 1
124 SUPPLY OFFICE 2 124 SUPPLY
OFFICE
125 STORAGE 2 125 STORAGE
126 COMM. 2 126 COMM.
128 STORAGE 2 128 STORAGE
201 STOR 2 201 STORAGE
202 STOR 2 202 STORAGE
203 BREAK /
CONFRENCE
1 203 BREAK /
CONFRENCE
203A BREAK /
CONFERENCE
6 - EXIIT
204 WOMEN 4 - WOMEN
205 JAN. 2 205 JANITOR
CLOSET
206 MEN 3 - MEN
207 1SG 1 207 OFFICE
208 COMMANDER 1 208 OFFICE
209 OPERATIONS 1 209 OFFICE
210 ADMIN 1 210 OFFICE
211 ELEC 2 211 ELECTRICAL
213 PERFORMANCE
/ REHEARSAL
HALL
2 213 PERFORMANC
E / REHEARSAL
HALL
213B PREFORMANCE
/ REHEARSAL
HALL
6 - EXIT
213C BREAK /
CONFERENCE
6 - EXIT
214 STORAGE 2 214 STORAGE
215 MECHANICAL 2 215 MECHANICAL
216 OPEN OFFICE 1 216 OFFICE
216A OPEN OFFICE 6 - EXIT
216A OPEN OFFICE 6 - EXIT
217 COMM 2 217 COMMUNICATI
ONS
218 ROCK
REHEARSAL
2 218 ROCK
REHEARSAL
218A ROCK
REHEARSAL
6 - EXIT
219 MECHANICAL /
ELECTRICAL
2 219 MECHANICAL /
ELECRICAL
C101 CORR. 6 - EXIT
C108 CORR. 6 - EXIT
C110 CORR. 6 128 EXIT
C201 CORR. 6 - EXIT
C206 CORR. 6 - EXIT
E1 ELEV. 7 E1 ELEV.
0' 6" 1'
GRAPHIC SCALE 3" = 1'-0"
3"
0' 1' 2'
GRAPHIC SCALE 1-1/2" = 1'-0"
6"3" 9"
0' 2' 3'
GRAPHIC SCALE 3/4" = 1'-0"
1'
AUGUST 12, 2019
M A
R K
D E
S C
R
IP
T
IO
N D
A
FINISH NOTES
1. CEILING MATERIALS VARY. REFER TO RCP FOR CEILING DESIGN.
2. REFER TO RCP FOR CEILING DESIGN. INSTALL GYPSUM BOARD OVER EXISTING BEAD
BOARD CEILING FOR ENTIRE SPACE. PROVIDE CLOUD CEILINGS AS INDICATED.
3. UNLESS NOTED OTHERWISE; PROVIDE 5/8" GYP. BOARD (TYPE X) ATTACHED TO EXIST.
BEAD BOARD @ BOTTOM CHORD OF ROOF TRUSSES ABOVE OTHER FINISH CEILING
NOTED IN SCHEDULE.
4. GYPSUM BOARD CEILING TO BE INSTALLED AT THE UNDERSIDE OF SECOND FLOOR
FRAMING. CEILINGS HEIGHTS SHOWN ARE ASSUMED BASED ON AS-BUILT DRAWINGS.
VERIFY HEIGHT OF EXISTING SECOND FLOOR FRAMING.
1'-0" 2'-0" 2'-0"
CFT-01 FIELD TILE
CFT-02 SHALL BE SPACED
36" O.C. VERT.& 24" O.C.
HORIZ. EQUALLY STAGGER
EVERY OTHER ROW.
ROOM CORNER
CFT-02 ACCENT BORDER
PATTERN SIMILAR TO
DALTILE SB1402B FLOOR TRANSITION SCHEDULE
LVT - VCT: JOHNSONITE SLT-XX-B, OR SIM.
LVT - CARPET: JOHNSONITE SLT-XX-A, OR SIM.
LVT - TILE: MARBLE THRESHOLD
VCT - SCONC: JOHNSONITE SSR-XX-B, OR SIM.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F O
R T
S A
M H
O U
S T
O N
T
E X
A S
I-611
R O
O M
F
IN
IS
H
S C
H E
D U
L E
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
F
O R
T S
A M
H O
U S
T O
N T
X
K E
N A
L L
F N
I S
A V
O Y
D R
IV
E
S
U
IT
E
H O
U S
T O
N T
E X
A S
P H
O N
E (8
-8
S L A
A R
C H
IT
E
C T
S
J D
IX
O
N
C H
O P
K
IN
S
A U
G U
S T
W G
B
FINAL SUBMITTAL
FINISH SCHEDULE
ROOM
NUMBER ROOM NAME
WALL FINISH BASE
FINISH FLOOR CEILING
CEILING
HEIGHT
NOTES & REMARKS (SEE
NOTES)NORTH EAST SOUTH WEST
101 OPEN OFFICE PT-1 PT-1 PT-1 PT-1 RB-1 CPT-1 PT-3 9'-4" 4
102 RECEPT. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 9'-4" 4
103 JAN PT-1 PT-1 PT-1/CTW-1 PT-1 RB-1 VCT-1 PT-3 9'-4" 4
104 WOMEN PT-5 /CTW-1 PT-1/CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 CTW-1 CTF-1 PT-5 9'-4" 4
105 WOMEN LOCKER PT-5 PT-5 PT-5 PT-5 RB-1 VCT-1 PT-5 9'-4" 4
106 SHOWERS PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 CTB-1 CTF-1 PT-5 9'-4" 4
107 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 9'-4" 4
108 MECHANICAL PT-1 PT-1 PT-1 PT-1 RB-1 EXC EXP --
109 ELECTRICAL ETR ETR ETR ETR RB-1 EXC EXP --
110 MACHINE EXM EXM EXM EXM -- EXC EXP --
111 MECHANICAL / ELECTRICAL PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
112 GROUP REHEARSAL 2 PT-1 PT-1 PT-1 PT-1 RB-1 CPT-1 PT-3 8'-4" 4
113 GROUP REHEARSAL 3 PT-1 PT-1 PT-1 PT-1 RB-1 CPT-1 PT-3 8'-4" 4
114 GROUP REHEARSAL 4 PT-1 PT-1 PT-1 PT-1 RB-1 CPT-1 PT-3 8'-4" 4
115 STG PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
116 INSTRUMENT MAINTENANCE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
117 MECH / ELECT PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
118 SPRINKLER PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
119 INSTRUMENT STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
120 MENS PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 CTW-1 CTF-1 PT-5 8'-4" 4
121 MEN SHOWER PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 CTW-1 CTF-1 PT-5 8'-4" 4
122 MEN LOCKER PT-5 PT-5 PT-5 PT-5 RB-1 VCT-1 PT-5 8'-4" 4
123 GROUP REHEARSAL 1 PT-1 PT-1 PT-1 PT-1 RB-1 CPT-1 PT-3 8'-4" 4
124 SUPPLY OFFICE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
125 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
126 COMM. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-2 PT-3 8'-4" 4
127 IND. PRACTICE ROOMS PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
128 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
201 STOR PT-1 PT-1 PT-1 PT-1 RB-1 LVT-1 PT-3 8'-0" 3
202 STOR PT-1 PT-1 PT-1 PT-1 RB-1 LVT-1 PT-3 8'-0" 3
203 BREAK / CONFERENCE PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 ACT-1 9'-4" 3
204 WOMEN PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 CTW-1 CTF-1 PT-5 9'-4" 3
205 JAN. PT-1 PT-1 PT-1 PT-1 RB-1 LVT-1 PT-3 8'-0" 3
206 MEN PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 PT-5 /CTW-1 CTW-1 CTF-1 PT-5 9'-4" 3
207 1SG PT-1 PT-1 PT-1 PT-1 WD-2 CPT-1 ACT-1 9'-4" 3
208 COMMANDER PT-1 PT-1 PT-1 PT-1 WD-2 CPT-1 ACT-1 9'-4" 3
209 OPERATIONS PT-1 PT-1 PT-1 PT-1 WD-2 CPT-1 ACT-1 9'-4" 3
210 ADMIN. PT-1 PT-1 PT-1 PT-1 WD-2 CPT-1 ACT-1 9'-4" 3
211 ELEC PT-1 PT-1 PT-1 PT-1 RB-1 LVT-1 ACT-1 9'-0" 3
212 VEST. ST-1 / PT-7 ST-1 / PT-7 ST-1 / PT-7 ST-1 / PT-7 WD-1 CPT-2 ACT-1 12'-8" 3
213 PERFORMANCE / REHEARSAL HALL ST-1 / PT-7 ST-1 / PT-7 ST-1 / PT-7 ST-1 / PT-7 WD-1 CPT-2 VARIES VARIES 1
214 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 ACT-1 12'-8" 3
215 MECHANICAL PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 15'-7" 3
216 OPEN OFFICE PT-1 PT-1 PT-1 PT-1 WD-2 CPT-1 VARIES VARIES 2
217 COMM PT-1 PT-1 PT-1 PT-1 RB-1 VCT-2 ACT-1 12'-8" 3
218 ROCK REHEARSAL PT-1 PT-1 PT-1 PT-1 WD-2 CPT-1 VARIES VARIES 2
219 MECHANICAL / ELECTRICAL PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 15'-7" 3
C101 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 9'-4" 4
C102 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 9'-4" 4
C103 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-6" 4
C104 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 EXP 4
C105 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
C106 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
C107 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
C108 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
C109 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 8'-4" 4
C110 CORR. PT-1 PT-1 PT-1 PT-1 RB-1 VCT-1 PT-3 VARIES 4
C201 CORR. PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 ACT-1 9'-4" 3
C202 CORR. PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 ACT-1 9'-4" 3
C203 CORR. PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 ACT-1 9'-4" 3
C204 CORR. PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 ACT-1 9'-0" 3
C205 CORR. PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 PT-3 8'-2" 3
C206 CORR. PT-1 PT-1 PT-1 PT-1 WD-2 LVT-1 ACT-1 12'-8" 3
WALL ACCENT PANELS WDW-1 MINWAX WOOD FINISH - PROVINCIAL 211 - STAINED WOOD WAINSCOT
WT-2 ENCORE - 22 oz. SYNTHETIC VELOUR PEWTER ACOUSTICAL DRAPES FOR WINDOWS
WINDOW TREATMENT
WT-1 - - - - - ROLLER SHADE
WALL PROTECTION CG-1 - - - - - TO MATCH PT1
WOOD STAIN ST-1 SHERWIN WILLIAMS SHER-WOOD - BRONZE WALNUT SW 3219 PERFROMANCE HALL
CEILING TILE ACT-1 ARMSTRONG ULTIMA - WHITE 24" x 24"
SP-3 KORASEAL - - WHITE - CEILING SOUND PANELS
SP-2 KORASEAL - - PHOTO PANELS - WALLS IN PERFORMANCE HALL WHERE NOTEDSOUND PANELS
SP-1 KORASEAL - - -
WALL SOUND PANEL COLOR UNLESS NOTED
OTHERWISE
SS-2 WILSONART QUARTZ - Q4023 SANTIAGO - COUNTERTOPS
SOLID SURFACE
SS-1 WILSONART QUARTZ - Q1007 POMPEII - WINDOW STOOLS
PLAM PLAM-1 ARBORITE - - W-465 EV - BASE / UPPER CABINETS
PT-8 SHERWIN WILLIAMS - - SW6119 ANTIQUE WHITE - PAINTED DOORS @ PERFORMANCE HALL
PT-7 SHERWIN WILLIAMS - -
SW0041 DARK HUNTER
GREEN
PERFORMANCE HALL STAINED WOOD
(WAINSCOT, BASE, DOOR & WINDOW TRIM,...
PT-6 SHERWIN WILLIAMS - - SW7018 DOVETAIL - PAINTED HOLLOW METAL DOORS & FRAMES
PT-5 SHERWIN WILLIAMS - SW7005 PURE WHITE -
PAINT COLOR FOR RESTROOMS, SHOWER AND
LOCKER ROOMS
PT-4 SHERWIN WILLAMS - -
SW0037 MORRISON ROOM
GREY
PAINT COLOR FOR SALVAGED TIN CEILING &
TRIM IN PERFORMANCE HALL
PT-3 SHERWIN WILLAMS - - SW7631 CITY LOFT - GWB CEILINGS
PT-2 SHERWIN WILLAMS - - SW6991 BLACK MAGIC -
WALLS @ HEIGHT INDICATED A.F.F.; GYPSUM
BOARD CEILINGS ABOVE AREAS WITH CLOUDS...
PAINT
PT-1 SHERWIN WILLIAMS - - SW7631 CITY LOFT - FIELD
GROUT GT-1
CUSTOM BLDG
PRODUCTS
- #60 CHARCOAL - -
CTW-3 DALTILE
MODERN
DIMENSIONS
- 0190 ARTIC WHITE 4.25" X 8.5" JANITOR CLOSET
CTW-2 DALTILE RITTENHOUSE 3" X 6" WALL TILE MATTE BLACK K711 3" X 6" WALL TILE ACCENTCERAMIC TILE WALL /
BASE
CTW-1 / CTB-1 DALTILE RITTENHOUSE 3" X 6" WALL TILE ARTIC WHITE 0190 3" X 6" WALL TILE FIELD
CTF-2 DALTILE KEYSTONES 1" HEXAGON DK16 BLACK D311 1" HEXAGON RESTROOM FLOOR ACCENT
CERAMIC TILE FLOOR
CTF-1 DALTILE KEYSTONES 1" HEXAGON DK16 ARTIC WHITE D617 1" HEXAGON RESTROOM FLOOR FIELD
VCT-2 ARMSTRONG SDT STATIC DISSIPATIVE TILE 51951 ARMOR GRAY 12" X 12" COMMUNICATION ROOMS
VCT-1 JOHNSONITE AZROCK VCT - V229 SHUTTLE GREY 12" X 12" JANITOR CLOSETS
LVT-2 SHAW HARD SURFACE JEOGORI 0215V LINEN 90500 18" X 18" BREAKROOM
FLOORING
LVT-1 ARMSTRONG PARALLEL 20 J6223 ROSE PARADE 6" X 48" CORRIDORS (SECOND FLOOR)
CPT-2 MOHAWK ORNATE METAL 588 TRANSCONTINENTAL PERFORMANCE HALL
CARPET
CPT-1 SHAW
MATERIAL
MATTERS
FRINGE TILE 5T038 SMOKE 37557 18" X 36" OFFICES
WD-2 SHERWIN WILLIAMS - - SW7018 DOVETAIL
WD-1 SHERWIN WILLIAMS - - SW 3219 - BRONZE WALNUT PERFORMANCE HALLBASE
RB - 1 JOHNSONITE
BASEWORKS
WALL BASE
COVE / TOELESS 32 PEBBLE 4"
COVE AT RESILIENT FLOORING / TOELESS AT
CARPET
FINISH FINISH CODE MANUFACTURER COLLECTION STYLE / NUMBER COLOR SIZE NOTES
FINISH COLOR SCHEDULE
1" = 1'-0"I-611
A1 FLOOR TILE PATTERN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
AUGUST 12, 2019
| General Sheets |
| Cover Sheet |
| Architectural Sheets |
| I-101 |
| I-102 |
| I-531 |
| I-611 |
| I-901 |
| IF101 |
| IF102 |
File details come from the government source that posted it.