NOT USED
NOT USED
FREE STANDING ENCLOSURE
PUMP CONTROL PANEL LEGEND
VIBRATING ALARM HORN (70db at 10 ft)
CABINET WITHIN PCP FOR SPARE PARTS
24 VOLT POWER SUPPLIES
RELAYS AND OTHER MISCELLANEOUS DEVICES
SYS-1 CPU RACK SYS-2 CPU RACK
T B
I N
ITEM DESCRIPTION ITEM DESCRIPTION
NOT USED
VENTS
UNINTERRUPTABLE POWER SUPPLY (UPS) WITHIN CABINET
PUMP CONTROL PANEL LEGEND CONT.
FANS
NOT USED
NAMEPLATE "SYSTEM INPUT SELECT"
NAMEPLATE "FUELING MODE SELECT"
NAMEPLATE "LEAD FUEL PUMP"
BACKLIGHT WINDOW ANNUNCIATOR
MOMENTARY CONTACT PUSHBUTTON WITH LEGEND PLATE "TEST"
NAMEPLATE "ANNUNCIATOR SYSTEM"
WHITE INDICATOR LIGHT
NAMEPLATE "CPU-2 ON"
NAMEPLATE "CPU-1 ON"
GREEN INDICATOR LIGHT
SYS-1 I/O RACK 1A
SYS-2 I/O RACK 2A
NAMEPLATE "EMERGENCY CIRCUIT POWER ON"
2 POSITION MAINTAINED CONTACT SELECTOR
SWITCH WITH LEGEND PLATE " SYS-1 SYS-2"
4 POSITION KEY OPERATED MAINTAINED CONTACT
SELECTOR SWITCH WITH LEGEND PLATE "AUTO
OFF FLUSH TEST"
3 POSITION MAINTAINED CONTACT SELECTOR SWITCH WITH
LEGEND PLATE "1 2 3" (CIRCULAR AROUND SWITCH)
LOCKABLE CABINET LOCATED WITHIN THE PCP FOR THE LAPTOP
COMPUTER.
MOMENTARY CONTACT PUSHBUTTON WITH LEGEND PLATE
"ACKNOWLEDGE"
MOMENTARY CONTACT PUSHBUTTON WITH LEGEND
PLATE "EMERGENCY STOP RESET"
RED JUMBO MUSHROOM MOMENTARY CONTACT
PUSHBUTTON WITH LEGEND PLATE "EMERGENCY
STOP"
SYS-1 I/O
RACK 1B (AS
REQUIRED)
SYS-2 I/O
RACK 2B (AS
REQUIRED)
24" MAX
M
A X
72" MAX
LEFT SIDE VIEW
FRONT VIEW
RIGHT SIDE VIEW
INTERIOR BACKPLANE MOUNTING PANEL
NOTES:
1. PROVIDE WIRE MANAGEMENT DUCTS.
2. FOLLOW THE ABOVE LAYOUT AS CLOSE AS POSSIBLE TO PROVIDE
UNIFORMITY WITH EXISTING AND FUTURE FUELING SYSTEM CONTROL PANELS.
VARIANCES CAN BE MADE TO ACCOMMODATE TANK LEVEL INTRINSICALLY
SAFE RELAYS WITHOUT EXPANDING PHYSICAL SIZE OF PANEL. SIDE PANELS
MAY BE UTILIZED FOR ADDITIONAL SPACE.
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
Project No. - FJRP159073
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
94893
C O
P Y
R I G
H T
B U
R N
S
M c D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
D
2 3
C
4 5
A
B
16 18
26 27
24 24
B1
PUMP CONTROL PANEL (PCP)
SCALE: NOT TO SCALE
SURGE ARRESTORS, THERMOSTATS,
POWER TERMINAL BLOCKS
T B
I N
T B
I N
T B
I N
T B
I N
T B
I N
T B
I N
T B
I N
T B
I N
T B
O
U T
T B
O
U T
T B
O
U T
QUICK DISCONNECT
RECEPTACLE
NAMEPLATE (TYP.)
28 EI501
94893EI501.DWG
PUMP CONTROL PANEL ELEVATION
A. FANGMAN
NOVEMBER 2016 J. LITTLE
S. LACY
1. SEE DRAWINGS EI502 THRU EI504 AND
EI601 THRU EI604 FOR OTHER CONTROL
PANEL RELATED REQUIREMENTS.
GENERAL NOTES: THIS DRAWING ONLY
RIGHT SIDE
PANEL LAYOUT
TB-IS-IN
TANK LEVEL
INTRINSICALLY
SAFE RELAYS