Appendix_1e_-_Drawings_5.pdf

PDF 16 MB Posted

Attached to
DESC1802 Replace POL Facilities Hill AFB, UT
Solicitation number
W91238-18-R-0020
Issued by

About this file

Appendix 1e - Drawings 5

View the file

Other files

File Type Posted
Appendix_1-Revised-Drawings-Am-0009.PDF PDF
W912838-18-R-0020-Am_0009_Narrative.pdf PDF
W91238-18-R-0020-0009.pdf PDF
Appendix_2-Revised-Specifications-Am-0009.pdf PDF
W91238-18-R-0020-0008.pdf PDF
Attachment_26_-_Price_Breakout_Schedule.xlsx XLSX spreadsheet
Amendment_0007_Narrative.pdf PDF
W91238-18-R-0020-0007.pdf PDF
Revised_Specifications_2.pdf PDF
Revised_Drawings_5.PDF PDF
Appendix_1b_-_Drawings-Am-6-2.docx DOCX document
W91238-18-R-0020-0006.pdf PDF
Appendix_1c_-_Drawings-Am-6-3.docx DOCX document
Appendix_1a_-_Drawings-Am-6-1rev.docx DOCX document
Appendix_2-Specifications-Am-6.pdf PDF
W912838-18-R-0020-Am_0006_Narrative.pdf PDF
Attachment_2_-_Revised_Supplemental_Contract_Requirements.pdf PDF
Appendix_1d_-_Drawings-Am-6-4.docx DOCX document
W91238-18-R-0020-0005.pdf PDF
POL_Pumphouse_Site_Walk_Photos_28_Aug.pdf PDF
Pre-Proposals_Site_Visit_Sign-In.pdf PDF
W912838-18-R-0020-Am-0002-Drawings.pdf PDF
33_52_43.11.pdf PDF
33_52_43.12.pdf PDF
33_52_43.23.pdf PDF
33_52_43.28.pdf PDF
33_52_43.14.pdf PDF
33_52_43.13.pdf PDF
33_56_10.pdf PDF
W91238-18-R-0020-0004_-_SF30.pdf PDF
W912838-18-R-0020-Am_00001_Narrative.docx DOCX document
W91238-18-R-0020-0003_-_Change_Project_Title.pdf PDF
W91238-18-R-0020-0001_-_Correct_Proposals_Due_Date.pdf PDF
Attachment_5_-_Cover_Letter.DOCX DOCX document
Appendix_1b_-_Drawings_2.pdf PDF
Attachment_7_-_Truck_Offload_FONSI.pdf PDF
Appendix_2_-_Specifications_for_Construction.pdf PDF
Attachment_1_-_SOW_Replace_POL_Facilities.DOCX DOCX document
Attachment_3_-_Wage_Determinations.docx DOCX document
Attachment_2_-_Supplemental_Contract_Requirements.docx DOCX document
Attachment_6_-_Truck_Offload_Environmental_Assessment.pdf PDF
Attachment_4_-_Acknowledgement_Statement.DOCX DOCX document
Appendix_1a_-_Drawings_1.pdf PDF
W91238-18-R-0020_-_SF1442.pdf PDF
Attachment_8_-_Site_Walk_Instructions.docx DOCX document
Appendix_1d_-_Drawings_4.pdf PDF
Appendix_1c_-_Drawings_3.pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-505.dwg

12:53:48 PM 6/21/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

TO 3% MAX.

SLOPE DOWN 1.5%

FTP-1

PG

P G

P G

PGPG

P G

IN VERTICAL PIPING

TEE CONNECTION

36" MANWAY

PIPING)

BEYOND TRANSFER

DRAIN PIPING(CONNECTION

TANK FILL/PUMPHOUSE

RELIEF VALVE

PUMP, FTP-1

FUEL TRANSFER

" VENT2

GRADE

TANK SADDLE

STRIKER PLATE

CHECK VALVE (CV-5)

2" NON-SURGE

SWITCH

FLOW

(TYP.)

STRIKER PLATE

FOOT VALVE

DATUM PLATE.

LIQUID LEVEL INDICATOR

SAME ELEVATION AS

DATUM PLATE. TO BE AT

1" GAP

INTERSTITIAL SPACE

MONITOR FOR

LEAK DETECTION

WATER DRAW-OFF

ATG SYSTEM

4" FLANGE FOR

NORMAL VENT

OV-1

OVERFILL VALVE

MINIMUM 10" FLANGE

CLOCK GAUGE

FLOAT SWITCH ASSEMBLY

VENT

EMERGENCY

1"

4"

GAUGING HATCH

4" SAMPLING AND

EMERGENCY VENT

TESTER

MANUAL

FLOW SWITCH

FOR 3% SLOPE

MANWAYS, AND VAULT

CORRECT PUMPWAYS,

2'-0" DIA.

OVERFILL VALVE AT TOP

2" FILL LINE WITH

AT 95% FILL

OVERFILL VALVE

FLOAT CLOSES

MANUALTESTER.

FLOAT WITH

FOR PAD DIMENSIONS

SEE CIVIL SHEET CS502

CHECK VALVE

BALL VALVE

CAPACITY

5 GALLONS MIN.

LID

DRAIN VALVE

A8

SECTION

SCALE: NO SCALE

A2

SECTION

SCALE: NO SCALE

E8

SPILL BUCKET DETAIL

SCALE: NO SCALE

E2

4000 GALLON PRODUCT RECOVERY TANK DETAIL

SCALE: NO SCALE

A8

M-505

M-505

A2

M-506

F1

ROOM

2" TO PUMP

LADDER

ELECTRIC PUMP

SPILL BUCKET

WITH DUSTCAP (TYP)

TYPE CONNECTOR

1.5 " MALE CAM

1.5 " PIPE AND

4"

VENT (MAIN)

EMERGENCY

STEEL TANK

U.L. 2085 DOUBLE WALL

CAP

2.5 " VENT WITH

ATG SYSTEM

4" FLANGE FOR

MONITOR

DETECTION

LEAK

VALVE (TYP)

PRESSURE RELIEF

STRAINER

OV-1

N.O. BALL VALVE

" QUICK DISCONNECT2

(0-300 PSI) (TYP)

PRESSURE GAGE

SUPPORT (TYP.)

SMALL BORE PIPE

FROM PUMPHOUSE

2" DRAIN LINE

FLOW SWITCH

CHECK FEATURE

VALVE WITH

FLOW CONTROL

FLOW SWITCH

FLOAT SWITCH

PS

AAV

GROUND LEVEL

VERTICAL PIPING NEAR

SAMPLE CONNECTION IN

(INTERSTITIAL)

EMERGENCY VENT

FTP-1

PUMP

UP TOWARDS

SLOPE PIPE

FOR PAD DIMENSIONS

SEE CIVIL SHEET CS502

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-505.dwg

12:53:48 PM 6/21/2018

H U

M -5

.d w g

C R

M

C C

H

C

E

E T O

F

D E

T A

IL

S

M-505

(TYP) IN VERTICAL PIPING

BALL VALVE & PRESSURE RELIEF

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-506.dwg

12:54:14 PM 6/21/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

PIPE SUPPORT

"4

" X 2

" X 22

4"4"

PLTYP.

PIPE SUPPORTS ARE REQUIRED.

CONCRETE CONTAINMENT WHERE SMALL BORE

1. USE CONCRETE BASE OUTSIDE OF AREAS OF

NOTES:

C1

BASE PLATE FOR SMALL BORE PIPE SUPPORT

SCALE: NO SCALE

D4

CONCRETE BASE FOR SMALL BORE PIPE SUPPORT

SCALE: NO SCALE

F1

SMALL BORE PIPE SUPPORT DETAIL

SCALE: NO SCALE

SUPPORT AND THE PIPE.

2. A TEFLON PAD SHALL BE INSERTED BETWEEN THE

U-BOLT.

PROTECT THE PIPING FROM THE METAL OF THE

1. U-BOLTS SHALL BE COATED OR OTHER MEANS TO

NOTES:

" DIA. HOLE (TYP.)16

6" 6"

6" 6"

EACH WAY

(2) #5 BARS

CONTINUOUSLY WELD

VARIES

" LEG4

13"X3"X

U-BOLT SIZE VARIES

PIPE SIZE VARIES

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-506.dwg

12:54:14 PM 6/21/2018

R

M

C C

H

C

E

E T O

F

D E

T A

IL

M-506

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-507.dwg

12:54:44 PM 6/21/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

PRODUCT SYMBOL

"A"

JET FUEL JP-8

"A"

BRANCH

1" WELDING

4 x "C"

ON BLACK BACKGROUND

"B" HIGH WHITE LETTERS

BLIND FLANGE

ARROW

YELLOW FLOW

REDUCER

" x 3" NIPPLE2

PIPE

ALL AROUND

YELLOW BANDS (3 EA.)

BALL VALVE

(INCHES)

PIPE DIAMETER

SIZES OF LETTERS AND BANDS

UNDER 3

3 - 6

6 - 9

OVER 9

4.5

(INCHES)

AND SPACING

BAND WIDTH

A

(INCHES)

SIZE

TITLE LETTER

B

0.5

(INCHES)

AND ARROWS

BACKGROUND

C

ON FILTER SEPARATORS, LOCK BALL VALVE OPEN USING PLASTIC STRAPS (CAR SEALS)

NOTE:

PIPE

BLIND FLANGE

BALL VALVE

1"x3" NIPPLE

WELDING BRANCH

RELIEF VALVE

BALL VALVE

90° ELBOW

N.O.

N.O.

LENGTH TO SUIT LOCATION

PRESSURE GAUGE

SURGE TANK

NITROGEN

1/2" SST. DRAIN VALVE

METAL SEATS

PRESSURE

" PSID CRACKING 2

CHECK VALVE

NON-SLAM, SILENT

FULL PORT BALL VALVE

ADJUSTMENT"

INTO SYSTEM "RHYTHM

TO ADJUST BACKFLOW

1/2" SST. NEEDLE VALVE

PSIG

0-300

UNION

"C

F-34

AND OUTLINE

YELLOW LETTERS

DAMPER

PULSATION

N.C.

G2

PRODUCT FLOW SYMBOL DETAIL

SCALE: NO SCALE

E4

PRESSURE GAGE PIPE CONNECTION DETAIL

SCALE: NO SCALE

E6

RELIEF VALVE PIPING DETAIL

SCALE: NO SCALE

A6

SURGE SUPPRESSOR TANK DETAIL

SCALE: NO SCALE

TANK SHELL

SLOPE

1" 10 GPM PUMP

SHUTOFF VALVE (TYP)

(TYP)

W/DENSITY BALL

SIGHT GLASS

BOTTOM AND REMOVABLE TOP

55 GALLON, W/CONE DOWN

WATER DRAW-OFF TANK

1" VENT

DISCONNECT WITH CAP

1" CAM TYPE QUICK

SSCS

LOCKABLE BALL VALVE

CHECK VALVE

GLOBE STYLE

FLANGES AT CS/SS INTERFACE

PROVIDE INSULATING KITS ON

CONCRETE HOUSEKEEPING PAD

W/QUICK DISCONNECT

1" MANUAL DRAIN

1" WATER DRAW-OFF

1" PST DRAIN

ANCHORS (TYP)

EQUIPMENT

1"

L E

N G

T H T

O S

U

IT

N T

S1" GROUT (TYP)

5'-0" (NTS)

TO NEW 2" TANK NOZZLE.

CONNECT NEW VALVE

A1

WATER DRAW-OFF SYSTEM DETAIL

SCALE: NO SCALE

1"

PILOT CHAMBER

SWITCHES & HLV FLOAT

HIGH-HIGH LEVEL

1/2" TO/FROM HIGH AND

PIPE LINE

CAP

THREADED

40 PIPE

" SCH. 4

BRANCH

" WELDING 4

FOR PIPE LINES 6" AND SMALLER.

KEEP DISTANCE AS SMALL AS POSSIBLE

2" MINIMUM FOR LINES 8" AND LARGER.

VALVE

" BALL 4

E9

MANUAL AIR VENT

SCALE: NO SCALE

TRANSMITTER

PRESSURE INDICATING

BAR STOCK PLUG

2" PIPE SUPPORT

VENTS

PRESSURE GAGE

VENT WITH BALL VALVE

PIT

PSI

N.O. BALL VALVE

PIPE TO PIT

CONTROL TUBING FROM

CONTINUOUSLY SLOPE

MANIFOLD (TYPICAL)

2 VALVE, STAINLESS STEEL,

FACTORY FABRICATED 1/2",

DRAIN

A T P

IT

A T P

IT

S

A8

PRESSURE TRANSMITTER PIPING DETAIL

NO SCALE

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-507.dwg

12:54:44 PM 6/21/2018

M

C C

H

C

E

E T O

F

D E

T A

IL

M-507

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-508.dwg

12:55:09 PM 6/21/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

4"

" PLATE4

BOLT. TACK WELD TO

" 316 S.S. FOUNDATION4

& WASHER

316 S.S. NUT

WEDGE

CASE IRON

PUMP PAD

" LEG4

13"x3"x

CONTINUOUSLY WELD

PIPE SUPPORT

"4 1"x 2

1"x22

"4 1PLATE 3"x3"x

" PIPE4

FLOWABLE EPOXY GROUT

PUMP BASE WITH A FULLY

GROUT SPACE UNDER

PUMP BASE

1" GROUT ALL AROUND

PUMP BASE

2" DIA. PIPE SLEEVE

JET FUEL JP-8

PRODUCT SYMBOL

ALL AROUND

YELLOW BANDS (3 EA.)

CONDENSED)

(LETTERS SHALL NOT BE

ON BLACK BACKGROUND

2" HIGH WHITE LETTERS

3"

3" F-34

YELLOW LETTERS AND OUTLINE

"2

" TEFLON PAD4

AND PIPE

BETWEEN BOLT

" TEFLON PAD 4

THE OPEN AREA FACES UPSTREAM

" SAMPLING PROBE SO4

1INSTALL

" THREADOLET4

" BALL VALVE4

CHAIN

DUST PLUG

QUICK DISCONNECT

FUEL LINE

M

IN

" U-BOLT4

THIS SHEET

SEE DETAIL "F"

PIPE SUPPORT

"4

AAV

1"

6" OUTLET

HAND HOLE

6" INLET

1"

LINE

1" FILL

END ELEVATION

1"

TESTER (FC-5)

VALVE W/MANUAL

FLOAT CONTROL

2" DRAIN

" AAV CONNECTION4

MAV AND AAV

DOOR

HINGED ACCESS

GAUGE

PRESSURE

DIFFERENTIAL

FSI-5

SIGHT GLASS

" DIAGONAL (TYP.)4

13"x3"x

" HOLE (TYP.)4

3W/

" BASE PLATE2

14" x 4

OUTSIDE OF SUPPORTS

W/ DUST CAP - EXTEND TO

MALE CAM TYPE CONNECTOR

(BALL VALVE) WITH ALUMINUM

1" MANUAL DRAIN VALVE

" LEGS (TYP.)4

13"x3"x

SAMPLE

6" OUTLET

CONNECTION

1" RELIEF VALVE

1" RELIEF VALVE

HAND HOLE

THIS SHEET

SEE DETAIL "K"

CONNECTIONS

SAMPLE

6" INLET

SIDE ELEVATION

1" FILL

1"

" PLUG4

DRAIN LINE

RUN TUBING TO

CONNECTION,

FLOAT DRAIN

PS

1"

AND BLIND FLANGE

ISOLATION VALVE

TEST TEE WITH

WITH CAP FOR MAV

NIPPLE

" x 3"4

3AND BLIND FLANGE

ISOLATION VALVE

TEST TEE WITH

2. FSR-1 THRU FSR-3 SIMILAR

1. TYPICAL FOR FSI-1 THRU FSI-3

NOTES:

BRACKET (TYP).

STAINLESS STEEL

AS POSSIBLE. (6" MAX.)

SHORT AND STRAIGHT

CONDUCTORS SHALL BE

PVC PROTECTOR

BRACKET.

CONNECTION

ARRESTER

MATERIAL

GASKET

INSULATING

MATERIAL

GASKET

INSULATING

WISCONSIN, OR APPROVED EQUAL.

INDUSTRIES, INC.", STROUGHTON,

FROM "DAIRYLAND ELECTRICAL

2, GROUP D HAZ. AREA. AVAILABLE

FOR INSTALLATION IN A CLASS 1, DIV.

SPECIFICATION 33 52 43.13, UL LISTED

LIGHTNING SURGE ARRESTER PER

TERMINAL

BOLTED OR COMPRESSION

ARRESTER EXPOSED.

WITH STAINLESS STEEL BAND CLAMP. LEAVE LIGHTNING SURGE

WRAP ENTIRE INSULATING FLANGE IN PVC PIPING AND SECURE

NOTE:

A7

LIGHTNING SURGE ARRESTER DETAIL

SCALE: NO SCALE

A5

SAMPLE CONNECTION DETAIL

SCALE: NO SCALE

A1

TYPICAL PUMP BASE MOUNTING DETAIL

SCALE: NO SCALE

D7

FILTER SEPARATOR PRODUCT SYMBOL DETAIL

SCALE: NO SCALE

D1

FILTER SEPARATOR DETAILS

SCALE: 3/4" = 1'-0"

F7

PIPE SUPPORT DETAIL

SCALE: NO SCALE

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05M-508.dwg

12:55:09 PM 6/21/2018

M

C C

H

C

E

E T O

F

D E

T A

IL

M-508

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI101.dwg

9:38:58 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI101.dwg

9:38:58 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I1

.d w g

M R

M

P F

W

P F

W

P

M P

H O

U S

E C

O N

T R

O L P

L A

N

EI101

REQUIRED IN NFPA 70 ARTICLE 504.

2. ALL REQUIRED INTRINSICALLY SAFE CIRCUITS TO BE INSTALLED AS

WITH SOUND DISTINCT FROM VIBRATING HORN.

1. VIBRATING HORN, 100dB AT 10 FEET & RESONATING HORN, 100 dB AT 10 FEET

KEYNOTES:

0 4' 8'2'

N

B1

PUMPHOUSE CONTROL PLAN

SCALE: 1/4" = 1' - 0"

PA

MDS

PUMP ROOM

CONTROL ROOM

MECHANICAL ROOM

PA

T-2

DESK

PB

PS

2 PS

PIT

PCP

J

J J J J1 J2 J3

J5

J J J4 J6

S

EPDS

UF

C30

S SESO-1 ESO-2

ESO-3

EPDS

UF

C30

EPDS

UF

C30

PCP

J

J14

UF

J18

J C40

UF

PCP

S S S S

S S J

J11

C27

C26 C24

C24

J J12

C19

UF

C23

UF

PCP

C18

C1

C2

C3

C4

C5

C6

C7

C8

C9

PCP

C10

C11

C12

PS

UF

UF

PCP

C22

PCP

M

MMJ

UF

PCP

C39C41

J19

C42

UF

C28

C29

J

J12C25

PCPMDS

MCC

C37

UF

C38

C38

PCP

MCC

UF

R11

R12

MCC

MCC

UF UFUF

MCC

R8 R9

R10

SHA

SHASHA

SHA

SHA

MCC

UF

MCC

C43

C44

TTP

UF

WP

WP

C45

C46

EPDS-5

UF

PCP

LA-1

C47

M

M

M

C40 C40

C42 UF

J PIT

J20 C44

TTP

UF

PCP

C30

C30

C30

C30

C50

LA

LAJ

J21

LA

J C51

C52

J22 C53

C54

C54

LA-2 LA-3

UF

UF

C48

FTRC

PUMP ROOM

CONTROL ROOM

MECHANICAL ROOM

UF

S M

MCC

UF

S M

MCC

UF

S M

MCC

UF

S M

MCC

UF

MCC

S M

UF

S M

PB-11

3. DISCONNECTING MEANS FOR MOTOR HEATER, MEETING ARTICLE 430.113 OF NFPA 70.

PNLS

ALARM

FIRE

EPDS-2

EPDS-4

EPDS-1

EP201

SEE SHEET

FCP

CABINET

PROT. TERMINAL

PIPELINES CTH.

PROT. RECTIFIER

PIPELINES CATH.

BACKBOARD

ATG

C32

C31

C26 C19

PANEL (PCP)

PUMP CONTROL

(TTP)

TEST PANEL

TIGHTNESS

PANEL

DISPLAY

GRAPHICS

EPDS-3

EPDS PANEL

PF

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI501.dwg

9:39:54 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI501.dwg

9:39:54 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P

M P C

O N

T R

O L P

A N

E L E

L E

V A

T

IO

EI501

POWER TERMINAL BLOCKS

SURGE ARRESTORS, THERMOSTATS,

24 VOLT POWER SUPPLIES

RELAYS AND OTHER MISCELLANEOUS DEVICES

SYS-1 CPU RACK

SYS-2 CPU RACK

T B -1

-IN

T B -2 -O

U T

T B -2

-IN

T B -3

-IN

T B -4

-IN

T B -5

-IN

T B -6

-IN

T B -7

-IN

T B -8

-IN

T B -2 -O

U T

T B -3 -O

U T

SYS-1 I/O RACK 1A

SYS-2 I/O RACK 2AT

B -9

-IN

(AS REQUIRED)

SYS-1 I/O RACK 1B

(AS REQUIRED)

SYS-2 I/O RACK 2B

NOT USED

NOT USED

FREE STANDING ENCLOSURE

PUMP CONTROL PANEL LEGEND

VIBRATING ALARM HORN (70db at 10 ft)

CABINET WITHIN PCP FOR SPARE PARTS

ITEM DESCRIPTION ITEM DESCRIPTION

NOT USED

VENTS

UNINTERRUPTABLE POWER SUPPLY (UPS) WITHIN CABINET

PUMP CONTROL PANEL LEGEND CONT.

FANS

NOT USED

NAMEPLATE "SYSTEM INPUT SELECT"

NAMEPLATE "FUELING MODE SELECT"

NAMEPLATE "LEAD FUEL PUMP"

BACKLIGHT WINDOW ANNUNCIATOR

MOMENTARY CONTACT PUSHBUTTON WITH LEGEND PLATE "TEST"

NAMEPLATE "ANNUNCIATOR SYSTEM"

WHITE INDICATOR LIGHT

NAMEPLATE "CPU-2 ON"

NAMEPLATE "CPU-1 ON"

GREEN INDICATOR LIGHT

NAMEPLATE "EMERGENCY CIRCUIT POWER ON"

1 16

2 POSITION MAINTAINED CONTACT SELECTOR SWITCH WITH LEGEND PLATE " SYS-1 SYS-2"

OFF FLUSH TEST"

4 POSITION KEY OPERATED MAINTAINED CONTACT SELECTOR SWITCH WITH LEGEND PLATE "AUTO

(CIRCULAR AROUND SWITCH)

3 POSITION MAINTAINED CONTACT SELECTOR SWITCH WITH LEGEND PLATE "1 2 3"

LOCKABLE CABINET LOCATED WITHIN THE PCP FOR THE LAPTOP COMPUTER.

MOMENTARY CONTACT PUSHBUTTON WITH LEGEND PLATE "ACKNOWLEDGE"

MOMENTARY CONTACT PUSHBUTTON WITH LEGEND PLATE "EMERGENCY STOP RESET"

RED JUMBO MUSHROOM MOMENTARY CONTACT PUSHBUTTON WITH LEGEND PLATE "EMERGENCY STOP"

LEFT SIDE VIEW

FRONT VIEW RIGHT SIDE VIEW

EXISTING AND FUTURE FUELING SYSTEM CONTROL PANELS.

2. FOLLOW THE ABOVE LAYOUT AS CLOSE AS POSSIBLE TO PROVIDE UNIFORMITY WITH

1. PROVIDE WIRE MANAGEMENT DUCTS.

NOTES:

1. SEE SHEETS EI502 THRU EI504 AND EI601 THRU EI604 FOR OTHER CONTROL PANEL RELATED REQUIREMENTS.

NOTES:

QUICK DISCONNECT

RECEPTACLE

T B -1

-IN

T B -1

-IN

T B -1

-IN

T B -1 -O

U T

D1

PUMP CONTROL PANEL (PCP)

SCALE: NTS

17 21

D7

INTERIOR BACKPLAIN MOUNTING PANEL

SCALE: NTS

T B -1

-IN

T B -1

-IN

Non-redundent

PUMP STATUS

TB-1-IN

TYPICAL TERMINAL BLOCK NAMEPLATE

ETC.

BLOCKS FOR CONNECTIONS TO ANNUNCIATOR, GRAPHICS PANEL, PERSONAL COMPUTER, HORNS,

ONLY. THE PUMP CONTROL PANEL MANUFACTURER MAY REQUIRE SEVERAL MORE TERMINAL

THESE TERMINAL BLOCK CONNECTIONS ARE INTENDED TO SHOW CONNECTIONS TO FIELD DEVICES

NOTE:

SHEET FOR FULL TEXT.

FIRST LINE OF TEXT SHALL BE 1/4 " HEIGHT AND THE SECOND AND/OR THIRD LINES SHALL BE 1/8 " HEIGHT. SEE THIS

24" MAX

M A

X

72" MAX

NAMEPLATE (TYP.)

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI502.dwg

9:40:43 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI502.dwg

9:40:43 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P

(S

E E

T O

F

G R

A P

H

IC

S D

IS

P L

A Y

EI502

PRODUCT RECOVERY TANK (4000 GAL.)

TRUCK FILL STANDS

S

S

BLUE (PRESSURIZED PIPE)B AMBER LIGHT

YELLOW(DRAIN/SUPPLY PIPE)

GREEN (RETURN PIPE)

Y

G GREEN LIGHT

RED LIGHT

COLOR (TYPE OF PIPE)

COLOR SCHEME LEGEND

MARK SYMBOL

INDICATOR LIGHT LEGEND

DESCRIPTION

COLOR SCHEME LEGEND

GREEN (RETURN PIPE)

YELLOW(DRAIN/SUPPLY PIPE)

BLUE (PRESSURIZED PIPE)

Y

G

B

MARK COLOR (TYPE OF PIPE) DESCRIPTION

INDICATOR LIGHT LEGEND

RED LIGHT

GREEN LIGHT

AMBER LIGHT

SYMBOL

3. SEE SPECIFICATIONS AND SHEET EI503 FOR USE OF LIMIT SWITCH(S) IN FIELD.

APPROVAL OF THE COMMAND FUEL ENGINEER.

2. DEVIATION FROM THIS GRAPHIC DISPLAY IS ALLOWED ONLY WITH

1. REFERENCE SHEET M-201, M-205 & M-206.

NOTES:

FP #1

RUN

STOP

RUN

STOP

FP #2

RUN

STOP

FP #3

RUN

STOP

FP #4

RUN

STOP

FP #5

RP-1

RUN

STOP

GPMISSUE FLOW

GPMRETURN FLOW

GPMNET FLOW

PSISYSTEM PRESSURE

FSI #1 FSI #2 FSI #3

FSR #1 FSR #2 FSR #3

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

SUCTION HEADER

CONTROL VALVE

BACK PRESSURE

VALVE

DEFUEL/FLUSH

VALVE

CONTROL

PRESSURE

VALVE

OVERFILL

Y

Y

Y

Y

B B B

B B B

B B B

B

B

B

B B

G

B

B

B

HEADER

DISCHARGE

PUMP

G

G

G G

GG

G

G

G

G

G

G

HIGH-HIGH LEVEL

HIGH LEVEL

STOP RUN

PUMP

FUEL TRANSFER OPEN

CLOSED

ENABLED CLOSED

OPEN CLOSED

ENABLED CLOSED

CONTINUED ON SHEET EI503

I45

I46

I28 I31 R14

R15

R16

R18 R19R21

R17

R25 R26 R27

I38 I39

I40 I41

I14 I13 R11

R12R13I15

I16 I17 I18

I19 I20 I21

R26

R20

R22 R23 R24

A1

GRAPHICS DISPLAY

SCALE: NTS

I22 I23 I24

I25 I26 I27

I36 I37

I34 I35

I32 I33

I30

I29

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI503.dwg

9:41:29 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI503.dwg

9:41:29 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P

(S

E E

T O

F

G R

A P

H

IC

S D

IS

P L

EI503

NO SCALE

TANK 10885

FLOW DIAGRAM

TANK 10873 TANK 10862 TANK 10861

TANK 10882

A T A

IR

F

IE

L D

T O O

P E

R A

T

IN

G T

A N

K S

S

S

TRUCK OFFLOAD 1

TRUCK OFFLOAD 2

HIGH - HIGH LEVEL

HIGH LEVEL

LOW LEVEL

LOW LOW LEVEL

HIGH - HIGH LEVEL

HIGH LEVEL

LOW LEVEL

LOW LOW LEVEL

HIGH - HIGH LEVEL

HIGH LEVEL

LOW LEVEL

LOW LOW LEVEL

HIGH - HIGH LEVEL

HIGH LEVEL

LOW LEVEL

LOW LOW LEVEL

G

G

G

B

Y Y

Y

Y

Y

Y Y Y Y

Y

G G G G

G

G

G

B

OPEN CLOSED

VALVE

OUTLET

OPEN CLOSED

VALVE

OUTLET

OPEN CLOSED

VALVE

OUTLET

OPEN CLOSED

VALVE

OUTLET

OPEN CLOSED

VALVE

OUTLET

OPEN CLOSED OPEN CLOSED OPEN CLOSED OPEN CLOSED

OPEN CLOSED

VALVE

INLET

VALVE

INLET

VALVE

INLET

VALVE

INLET

VALVE

INLET

CONTINUED ON SHEET EI502

I2A

I2B

R2A

R2B

R1A

R1B

I1A

I1B

I3A

I3B

R3A

R3B

I4A

I4B

R4A

R4B

R5A

R5B

I5A

I5B

RUNSTOP

RUNSTOP

TANK1

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

OPEN CLOSED

I1 I2 I3 I4

I5

R1 R2 R3 R4

R5

I12 R10 R9 I11

I7

I6

I10

R8

OPEN

CLOSED

OPEN

CLOSED

OPEN

CLOSED

OPEN

CLOSED

OPEN

CLOSED

OPEN

CLOSED

OPEN

CLOSED

OPEN CLOSED

R6

OPEN CLOSED

R7

CONTRACTOR SHALL USE PROGRAM LOGIC IN PCP TO OUTPUT TEXT ON GRAPHICS DISPLAY AS SHOWN IN KEYNOTE 2 THIS SHEET.

3. SEE SPECIFICATIONS AND SHEET EI502 FOR USE OF LIMIT SWITCH(S) IN FIELD.

APPROVAL OF THE COMMAND FUEL ENGINEER.

2. DEVIATION FROM THIS GRAPHIC DISPLAY IS ALLOWED ONLY WITH

1. REFERENCE SHEET M-201, M-205 &M206.

NOTES:

"RECIRCULATION THROUGH ISSUE FS TO TANK #"

OR

"TRANSFER FUEL BULK TANK#"

OR

"TRANSFER FUEL TO OPERATING TANK#"

OR

"TRANSFER FUEL TO TANK#"

OR

OUTPUT- "FILLING FROM OFFLOAD"

OR

OUTPUT - "FILLSTAND TRUCKS"

OR

OUTPUT- "FILL FROM PIPELINE"

2. TEXT OUTPUT EXAMPLE(S) FOR TANK 1 THRU 5:

FIELD INSTALLED LIMIT SWITCHES OUTPUTS, WILL BE INCORPORATED INTO THIS TEXTUAL OUTPUT.

OPERATION AND PROGRAMMING OF TEXT OUTPUT AT EACH TANK.

1. SEE SHEET M-205 PARAGRAPH LABELED "MANUAL VALVE OPERATION"& M-206 FOR SEQUENCE OF

KEY NOTES:__

1 1 1 1

TANK2 TANK3 TANK4

TANK5

C1

GRAPHICS DISPLAY

SCALE: NTS

HIGH - HIGH LEVEL

HIGH LEVEL

LOW LEVEL

LOW LOW LEVEL

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI504.dwg

9:42:15 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI504.dwg

9:42:15 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P

E E

T

T E

R M

IN

A L B

L O

C K C

O N

N E

C T

IO

N

EI504

FP-1

FP-2

FP-3

RP-1

TB-1-IN

PUMP STATUS

Non-redundent

SR1

SR2

SR3

120V UPS

NONREDUNDANT MODULE

INPUT

DISCRETE

SYSTEM-1

MODULE

INPUT

DISCRETE

SYSTEM-2

FTP-1

MC

MC

OLP-2

MC

OLP-1

FP-4

SR4

FP-5

SR5

SPARE{

SPARE{

FS-1

FS-2

FS-3

FS-4

TB-2-IN

FLOW SWITCH

System #1

MODULE

INPUT

DISCRETE

SYSTEM-2

MODULE

INPUT

DISCRETE

SYSTEM-1

120V UPS

SYSTEM-1

FS-5

FS-6

(RP-1)

(FP1)

FS-8

(FILLS.#2)

(FILLS.#1)

FS-7

FS-1

FS-2

FS-3

FS-4

MODULE

INPUT

DISCRETE

SYSTEM-2

MODULE

INPUT

DISCRETE

SYSTEM-1

120V UPS

SYSTEM-1

FS-5

FS-6

(RP-1)

(FP1)

FS-8

FS-7

(FILLS.#1)

(FILLS.#2)

TB-3-IN

FLOW SWITCH

System #2

TB-5-INTB-4-IN

TANK #1

LLLA

TANK #1

OUTLET

VALVE

TANK #1

HLA

TANK #1

HHLA

TANK #2

LLLA

TANK #2

OUTLET

VALVE

TANK #2

HHLA

TANK #2

HLA

TANK #1

LLLA

TANK #1

OUTLET

VALVE

TANK #1

HLA

TANK #1

HHLA

TANK #2

LLA

TANK #2

OUTLET

VALVE

TANK #2

HHLA

TANK #2

HLA

OPERATIONAL TANKS

System #1

OPERATIONAL TANKS

System #2

SYSTEM-1

120V UPS

{SPARE

SYSTEM-2

120V UPS

{SPARE

SYSTEM-1

DISCRETE

INPUT

MODULE

SYSTEM-2

DISCRETE

INPUT

MODULE

SYSTEM-1

DISCRETE

INPUT

MODULE

SYSTEM-2

DISCRETE

INPUT

MODULE

CLOSED

CLOSED

CLOSED

CLOSED

TANK #2

LLLA

TANK #1

LLA

TANK #2

LLA

TANK #1

LLA

TB-6-IN

TANK #3

LLLA

TANK #3

OUTLET

VALVE

TANK #3

HLA

TANK #3

HHLA

TANK #4

LLLA

TANK #4

OUTLET

VALVE

TANK #4

HHLA

TANK #4

HLA

OPERATIONAL TANKS

System #1

SYSTEM-1

120V UPS

{SPARE

SYSTEM-1

DISCRETE

INPUT

MODULE

SYSTEM-2

DISCRETE

INPUT

MODULE

CLOSED

CLOSED

TANK #4

LLA

TANK #3

LLA

TB-7-IN

OPERATIONAL TANKS

System #2

SYSTEM-2

120V UPS

{SPARE

SYSTEM-1

DISCRETE

INPUT

MODULE

SYSTEM-2

DISCRETE

INPUT

MODULE

TANK #3

LLLA

TANK #3

OUTLET

VALVE

TANK #3

HLA

TANK #3

HHLA

TANK #4

LLLA

TANK #4

OUTLET

VALVE

TANK #4

HHLA

TANK #4

HLA

CLOSED

CLOSED

TANK #4

LLA

TB-08-IN

TANK #5

LLLA

TANK #5

OUTLET

VALVE

TANK #5

HLA

TANK #5

HHLA

OPERATIONAL TANKS

System #1

SYSTEM-1

120V UPS

SYSTEM-1

DISCRETE

INPUT

MODULE

SYSTEM-2

DISCRETE

INPUT

MODULE

CLOSED

TANK #5

LLA

{SPARE

{SPARE

{SPARE

TB-09-IN

OPERATIONAL TANKS

System #2

SYSTEM-2

120V UPS

SYSTEM-1

DISCRETE

INPUT

MODULE

SYSTEM-2

DISCRETE

INPUT

MODULE

TANK #5

LLLA

TANK #5

OUTLET

VALVE

TANK #5

HLA

TANK #5

HHLA

CLOSED

TANK #5

LLA

{SPARE

{SPARE

{SPARE

TB-10-IN

EMERGENCY

STOP STATUS

EMERGENCY SHUTOFF

VALVE STATUS

EMERGENCY CIRCUIT

POWER STATUS

PRODUCT RECOVERY

TANK OVERFILL

PRODUCT RECOVERY

TANK LEAK DETECTION

PRODUCT RECOVERY

MISCELLANEOUS

Non-Redundant

SYSTEM-2

DISCRETE

INPUT

MODULE

SYSTEM-1

DISCRETE

INPUT

MODULE

CR3

ER1

ER2

ER3

NONREDUNDANT

120V UPS

PUMPROOM

EMERGENCY SHOWER

FLOWSWITCH

VALVE OPEN

TANK 1 OUTLET 25

TANK 2 OUTLET

VALVE OPEN

PRODUCT RECOVERY

CR2

TANK HHLA

TANK 3 OUTLET

VALVE OPEN

TANK 4 OUTLET

VALVE OPEN

FS-9

(OFFLD #1)

FS-10

(OFFLD #2)

FS-9

(OFFLD #1)

FS-10

(OFFLD #2)

{SPARE {SPARE

CONTINUED ON NEXT SHEET

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI505.dwg

9:42:51 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI505.dwg

9:42:51 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P F

W

S L

E E

T

T E

R M

IN

A L B

L O

C K C

O N

N E

C T

IO

N

EI505

MISCELLANEOUS

Non-Redundant

NONREDUNDANT

120V UPS

SYSTEM-2

DISCRETE

INPUT

MODULE

SYSTEM-1

DISCRETE

INPUT

MODULE

I1

VALVE

OPEN

I1

VALVE

CLOSED

I2

VALVE

OPEN

I2

VALVE

CLOSED

I3

VALVE

OPEN

I3

VALVE

CLOSED

I4

VALVE

OPEN

I4

VALVE

CLOSED

TB-10-IN

CONTINUED

VALVE

OPEN

VALVE

CLOSED

I5

I5

MISCELLANEOUS

Non-Redundant

NONREDUNDANT

120V UPS

SYSTEM-2

DISCRETE

INPUT

MODULE

SYSTEM-1

DISCRETE

INPUT

MODULE

TB-10-IN

CONTINUED

TANK 5 OUTLET

VALVE OPEN

{SPARE

{SPARE

SPARE{

TB-11-IN

SYS-1

ANALOG

INPUT

MODULE

SYSTEM-1

24VDC POWER

SUPPLY

PRESSURE SENSORS

Sys. #1 - Non-Redundant

UPSTREAM

OF BPCV

DOWNSTREAM

OF BPCV

PUMP #1

DISCHARGE

PS

PS

PS

SPARE{

SPARE{

SPARE{

SPARE{

SPARE{

MODULE

INPUT

DISCRETE

SYSTEM-2

MODULE

INPUT

DISCRETE

SYSTEM-1

120V UPS

NONREDUNDANT

TB-12-IN

Non - Redundant

MISCELLANEOUS

R1

VALVE

OPEN

R1

VALVE

CLOSED

R2

VALVE

OPEN

R2

VALVE

CLOSED

R3

VALVE

OPEN

R3

VALVE

CLOSED

R4

VALVE

OPEN

R4

VALVE

CLOSED

R5

VALVE

OPEN

R5

VALVE

CLOSED

R2A

VALVE

OPEN

R2A

VALVE

CLOSED

R3A

VALVE

OPEN

R3A

VALVE

CLOSED

R4A

VALVE

OPEN

R4A

VALVE

CLOSED

R5A

VALVE

OPEN

R5A

VALVE

CLOSED

R2B

VALVE

OPEN

R2B

VALVE

CLOSED

R3B

VALVE

OPEN

R3B

VALVE

CLOSED

R4B

VALVE

OPEN

R4B

VALVE

CLOSED

MODULE

INPUT

DISCRETE

SYSTEM-2

MODULE

INPUT

DISCRETE

SYSTEM-1

120V UPS

NONREDUNDANT

TB-13-IN

Non - Redundant

MISCELLANEOUS

R5B

VALVE

OPEN

R5B

VALVE

CLOSED

R1A

VALVE

OPEN

R1A

VALVE

CLOSED

R1B

VALVE

OPEN

R1B

VALVE

CLOSED

R8

VALVE

OPEN

R8

VALVE

CLOSED

R9

VALVE

OPEN

R9

VALVE

CLOSED

R10

VALVE

OPEN

R10

VALVE

CLOSED

R6

VALVE

OPEN

R6

VALVE

CLOSED

R7

VALVE

OPEN

R7

VALVE

CLOSED

I2A

VALVE

OPEN

I2A

VALVE

CLOSED

I3A

VALVE

OPEN

I3A

VALVE

CLOSED

I4A

VALVE

OPEN

I4A

VALVE

CLOSED

I5A

VALVE

OPEN

I5A

VALVE

CLOSED

MODULE

INPUT

DISCRETE

SYSTEM-2

MODULE

INPUT

DISCRETE

SYSTEM-1

120V UPS

NONREDUNDANT

TB-14-IN

Non - Redundant

MISCELLANEOUS

I2B

VALVE

OPEN

I2B

VALVE

CLOSED

I3B

VALVE

OPEN

I3B

VALVE

CLOSED

I4B

VALVE

OPEN

I4B

VALVE

CLOSED

I5B

VALVE

OPEN

I5B

VALVE

CLOSED

I1A

VALVE

OPEN

I1A

VALVE

CLOSED

I1B

VALVE

OPEN

I1B

VALVE

CLOSED

I2B

VALVE

OPEN

I2B

VALVE

CLOSED

I6

VALVE

OPEN

I6

VALVE

CLOSED

I7

VALVE

OPEN

I7

VALVE

CLOSED

I10

VALVE

OPEN

I10

VALVE

CLOSED

I11

VALVE

OPEN

I11

VALVE

CLOSED

I12

VALVE

OPEN

I12

VALVE

CLOSED

FS-1

WATER

HLA

FS-2

WATER

HLA

FS-3

VALVE

HLA

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI506.dwg

9:43:32 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI506.dwg

9:43:32 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P

E E

T

T E

R M

IN

A L B

L O

C K C

O N

N E

C T

IO

N

EI506

TB-1-OUT

AUTO PUMP

START/DISABLE

{FP-1 CONTROL

CIRCUIT

{FP-2 CONTROL

CIRCUIT

{FP-3 CONTROL

CIRCUIT

TB-2-OUT

BACKPRESSURE

SOLENOID A

DEFUEL/FLUSH

SOLENOID B

DEFUEL/FLUSH

SOLENOID A

PRESSURE

CONTROL

SOLENOID A

MISCELLANEOUS

120VAC

SYSTEM-1

DISCRETE

OUTPUT

MODULE

SYSTEM-2

DISCRETE

OUTPUT

MODULE

SYSTEM-1

ISOLATED

DISCRETE

OUTPUT

MODULE

SYSTEM-2

ISOLATED

DISCRETE

OUTPUT

MODULE

NONREDUNDANT

120V UPS

E-STOP

E-STOP

RESET{

TB-3-OUT

ALARM

ANNUNCIATOR

EXTERIOR

VIBRATING HORN

EXTERIOR

RESONATING HORN

ALARM

ANNUNCIATOR

MISCELLANEOUS

Non-Redundent

E-STOP AT FCC

ANNUNCIATOR VIA

TELE. BACKBOARD

EMERGENCY

STOP

CIRCUITS

IN MCC

{EXTERIOR

RESONATING HORN

{EXTERIOR

VIBRATING HORN

MOV 1

OPEN

CONTROL

MOV 1

CLOSE

CONTROL

BACKPRESSURE

SOLENOID B

PRESSURE

CONTROL

SOLENOID B

OPEN

CONTROL

CLOSE

CONTROL

MOV 2

MOV 2

OPEN

CONTROL

CLOSE

CONTROL

MOV 3

MOV 3

OPEN

CONTROL

CLOSE

CONTROL

MOV 4

MOV 4

OPEN

CONTROL

CLOSE

CONTROL

MOV 5

MOV 5

{FP-4 CONTROL

CIRCUIT

{FP-5 CONTROL

CIRCUIT

OPEN

CONTROL

CLOSE

CONTROL

MOV 6

MOV 6

CIRCUIT

RP-1 CONTROL {

SPARE {

SPARE {

SPARE {29

CIRCUIT

OP-1 CONTROL {

CIRCUIT

OP-2 CONTROL {

CIRCUIT

FTP-1 {

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI507.dwg

9:46:28 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

120 V

ER1

(FCC OFFICE) BUILDING 914

PCP

OUT

TB-3-

CONTROL ROOM IN NEW PUMPHOUSE

EPDS SYSTEM IN MCC

FCC

EPDS-20

PUMPS)

SWITCH (FUEL

POWER DOWN

EMERGENCY

MOMENTARY CONTACT.

NORMALLY CLOSED

PUSHBUTTON

RED MUSHROOM

SEE DETAIL, THIS SHEET.

PUMP EPDS PANEL.

NEW REMOTE FUEL

CONTROL RELAY

LOW SENSITIVITY

TRIGGER CIRCUIT

COMPUTER

PERSONAL

MODEM

MODEM

COMPUTER

PERSONAL

CONTROL CAPABILITY

ROOM BUT WILL HAVE NO

ONE IN THE CONTROL

SAME SCREENS AS THE

TO SHOW ALL OF THE

PERSONAL COMPUTER

BACKBOARD

TELEPHONE

BACKBOARD

TELEPHONE

SEE DETAIL

THIS

DRAWING

NEW REMOTE FUEL

PUMP EPDS PANEL

NEW 1-4 PR, #24 AWG

TEL. COND. IN

4" C

CONTACT BASE 75TH CS TO

OBTAIN TWO DEDICATED PAIRS

OF TELEPHONE WIRES FROM FCC

BLDG. TO THE NEW PUMPHOUSE

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI507.dwg

9:46:28 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I5

.d w g

M R

M

P F

W

P

E

D S C

O N

T R

O L S A

T F

C

EI507

C1

FCC OFFICE CONTROL ROOM REMOTE EPDS SCHEMATIC

SCALE: NTS

D7

REMOTE FUEL PUMP EPDS PANEL

SCALE: NTS

B7

TYPICAL EXISTING (FCC) TELEPHONE BACKBOARD

SCALE: NTS

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI601.dwg

9:47:01 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI601.dwg

9:47:01 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M D

IA

G R

A M

EI601

(W

IT

E

(R E

D

(R E

D

(W H

IT

E

(R E

D

(W H

IT

E

(W H

IT

E

(W H

IT

E

(W H

IT

E

(R E

D

(W H

IT

E

(R E

D

P O

W E

R S

U P

P L

Y M

O D

U L E

P O

W E

R S

U P

P L

Y M

O D

U L E

C O

M M

U N

IC

A T

IO

N M

O D

U L E

C O

M M

U N

IC

A T

IO

N M

O D

U L E

D

IS

C R

E T

E I

N P

U T M

O D

U L E (S

D

IS

C R

E T

E I

N P

U T M

O D

U L E (S

D

IS

C R

E T

E I

N P

U T M

O D

U L E (S

A N

A L

O G O

U T P

U T M

O D

U L E (S

N O

N R

E D

U N

D A

N T

S Y

S T

E M -1

S Y

S T

E M -2

T V

S S

S Y

S T

E M -1

V

D C

P O

W E

R S

U P

P L

Y

S Y

S T

E M -1

V A

C

F

IE

L D D

E V

IC

E S

S Y

S T

E M -1

V

D C

F

IE

L D D

E V

IC

E S

120VAC

CIRCUIT

P O

W E

R S

U P

P L

Y M

O D

U L E

P O

W E

R S

U P

P L

Y M

O D

U L E

C O

M M

U N

IC

A T

IO

N M

O D

U L E

C O

M M

U N

IC

A T

IO

N M

O D

U L E

D

IS

C R

E T

E I

N P

U T M

O D

U L E (S

D

IS

C R

E T

E I

N P

U T M

O D

U L E (S

D

IS

C R

E T

E I

N P

U T M

O D

U L E (S

A N

A L

O G O

U T P

U T M

O D

U L E (S

N O

N R

E D

U N

D A

N T

S Y

S T

E M -1

S Y

S T

E M -2

T V

S S

S Y

S T

E M -2

V

D C

P O

W E

R S

U P

P L

Y

S Y

S T

E M -2

V A

C

F

IE

L D D

E V

IC

E S

S Y

S T

E M -2

V

D C

F

IE

L D D

E V

IC

E S

120VAC

CIRCUIT

T V

S

S120VAC

CIRCUIT

LAPTOP RECEPTACLE

NONREDUNDANT

FIELD DEVICES

24VDC POWER SUPPLY

FOR REQUIRED PCP

DEVICES

120VAC FOR REQUIRED

PCP AND GDP DEVICES

ANNUNCIATOR & RELATED

ALARM DEVICES

T H

E R

M O

S T

A T A

N D

F A

N N

U M

B E

R

T H

E R

M O

S T

A T A

N D

F A

N N

U M

B E

R

MONITOR

WITH

(PC)

COMPUTER

PERSONAL

SYS-1 CPU RACK

SYS-2 CPU RACK

S Y

S T

E M -1

S Y

S T

E M -1

S Y

S T

E M -2

S Y

S T

E M -2

C P

U -1 M

O D

U L E

C P

U -2 M

O D

U L E

SYSTEM-1 INPUT/OUTPUT RACK #1 (I/O-1)

SYSTEM-2 INPUT/OUTPUT RACK #2 (I/O-2)

A N

A L

O G I

N P

U T M

O D

U L E (S

N O

N R

E D

U N

D A

N

TPOWER SUPPLY NO. 1

UNINTERRUPTABLE

SYSTEM-1

D

IS

C R

E T

E O

U T P

U T M

O D

U L E (S

D

IS

C R

E T

E O

U T P

U T M

O D

U L E (S

VALVE CLOSED

TANK OVERFILL

RECOVERY

PRODUCT

TANK HIGH LEVEL

PRODUCT RECOVERY

TANK HIGH-HIGH LEVEL

PRODUCT RECOVERY

HIGH-HIGH LEVEL

TANK #3

OPERATING

PRINTER

LASER

MODEM

POWER SUPPLY NO. 3

UNINTERRUPTABLE

MONITOR

WITH

COMPUTER

FCC

MODEM

POWER SUPPLY NO. 2

UNINTERRUPTABLE

SYSTEM-2

SCREEN

LED

DISPLAY

GRAPHIC

PANEL

TEST

TIGHTNESS

SYSTEM-1 PLC FAILURE

PLC FAILURE

SYSTEM-2

SYSTEM-1 DATA FAILURE

DATA FAILURE

SYSTEM-2

EMERGENCY STOP

PUMP ROOM

SHOWER ALARM

EMERGENCY

(W H

IT

E

(W H

IT

E

(R E

D

(W H

IT

E

)FUEL PUMP #1 FAILURE

FUEL PUMP #2 FAILURE

FUEL PUMP #3 FAILURE

(W H

IT

E

PCP HIGH TEMPERATURE

DETECTED

TANK LEAK

RECOVERY

PRODUCT

HIGH LEVEL

TANK #3

OPERATING

LOW LEVEL

TANK #3

OPERATING

LOW-LOW LEVEL

TANK #3

OPERATING

LOW-LOW LEVEL

TANK #4

OPERATING

LOW LEVEL

TANK #4

OPERATING

HIGH LEVEL

TANK #4

OPERATING

HIGH-HIGH LEVEL

TANK #4

OPERATING

4. CRITICAL ALARMS SHALL STOP ALL PUMPS RUNNING IN AUTOMATIC MODE.

PANEL HORN.

THE WHITE WINDOW ALARMS (NON-CRITICAL) SHALL SOUND THE EXTERIOR VIBRATING HORNS AND THE PUMP CONTROL

3. RED WINDOW ALARMS (CRITICAL) SHALL SOUND THE EXTERIOR RESONATING HORNS AND PUMP CONTROL PANEL HORN.

2. (RED) - RED WINDOW WITH BLACK LETTERS

1. (WHITE) - WHITE WINDOW WITH BLACK LETTERS

NOTES:

PLC MANUFACTURER

AS REQUIRED BY

(W H

IT

E

(R E

D

(W H

IT

E

(W H

IT

E

(W H

IT

E

(W H

IT

E

(W H

IT

E

)FAILURE

OFFLOAD PUMP#1

FAILURE

OFFLOAD PUMP#2

(W H

IT

E

(R E

D

(R E

D

(W H

IT

E

(R E

D

(W H

IT

E

(W H

IT

E

(R E

D

HIGH-HIGH LEVEL

TANK #1

OPERATING

HIGH LEVEL

TANK #1

OPERATING

LOW LEVEL

TANK #1

OPERATING

LOW-LOW LEVEL

TANK #1

OPERATING

LOW-LOW LEVEL

TANK #2

OPERATING

LOW LEVEL

TANK #2

OPERATING

HIGH LEVEL

TANK #2

OPERATING

HIGH-HIGH LEVEL

TANK #2

OPERATING

(W H

IT

E

(R E

D

(W H

IT

E

(R E

D

LOW-LOW LEVEL

TANK #5

OPERATING

LOW LEVEL

TANK #5

OPERATING

HIGH LEVEL

TANK #5

OPERATING

HIGH-HIGH LEVEL

TANK #5

OPERATING

OFFLOADS

SHOWER ALARM

EMERGENCY

(R E

D

SENS.#1

SPR. WATER

RECPT. FILTER

SENS.#2

SPR. WATER

RECPT. FILTER

SENS.#3

SPR. WATER

RECPT. FILTER

(W H

IT

E

(BLANK)

(W H

IT

E

(BLANK)

(W H

IT

E

(W H

IT

E

(W H

IT

E

FUEL PUMP #4 FAILURE

(W H

IT

E

FUEL PUMP #5 FAILURE

(W H

IT

E

(BLANK)

(W H

IT

E

C1

CONTROL SYSTEM BLOCK DIAGRAM

SCALE: NTS

D6

ANNUNCIATOR PANEL LAYOUT

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI602.dwg

9:47:55 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

MCC

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

L O

W

L O

W

PLC IN PCP

SYSTEM-2

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

VALVE

OUTLET

10885

OPERATING TANK

VALVE

OUTLET

10873

OPERATING TANK

DI DI DI DI DI DI DI DI DI DI DI DI

DIDIDIDIDIDIDIDIDIDIDIDI

DIDIDIDI

LSHH

LSL

LSH

ZS

DIDI DIDI

O P

E N

O P

E N

DI

O P

E N

O P

E N

DI

I2

O S

E D

O S

E

E

E N

DI DI

DIDI

VALVE

INLET

LSLL

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

DI DI

DIDI

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

DI DI

DIDI

LSLL

I1

O S

E

O S

E

E

E N

VALVE

INLET

MCC

PLC IN PCP

SYSTEM-2

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

I1 8"

I2 8"

R2AO

R2AC

R2A

R2BO

R2BC

VALVE

R2B

E N

DI

R

E N

DI

O S

E D

DI

R

O S

E D

DI

R

B

E N

DI

R

E N

DI

DI

R

O S

E D

R

O S

E

R1AO

R1AC

VALVE

R1A

R1BO

R1BC

VALVE

R1B

R

E N

DI

R

E N

DI

DI

R

O S

E D

R

O S

E D

DI

R

E N

DI

R

E N

DI

DI

R

O S

E D

R

O S

E

I2BO

I2BC

I2B

I2AO

I2AC

VALVE

I2A

E N

DI

E N

DI

DI

O S

E D

O S

E D

DI

E N

DI

E N

DI

DI

O S

E D

O S

E D

DI

I1AO

I1AC

VALVE

I1A

I1BO

I1BC

VALVE

I1B

DI

DI

DI

DI

O S

E D

O S

E D

DI

DI

DI

DI

O S

E D

O S

E D

E N

E N

E N

E N

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI602.dwg

9:47:55 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M I /O

EI602

T C

H L

IN

E

T

I6

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI603.dwg

9:48:29 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

MCC

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

L O

W

L O

W

PLC IN PCP

SYSTEM-2

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

VALVE

OUTLET

10862

OPERATING TANK

VALVE

OUTLET

10861

OPERATING TANK

DI DI DI DI DI DI DI DI DI DI DI DI

DIDIDIDIDIDIDIDIDIDIDIDI

DIDIDIDI

DIDI DIDI

O P

E N

O P

E N

O P

E N

O P

E N

DI

O S

E

O S

E

E

E N

VALVE

INLET

LSLL

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

DI DI

DIDI

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

LSLL

O S

E

O S

E

E

E N

INLET

R3AO

R3AC

R3A

R3BO

R3BC

VALVE

R3B

R

E N

DI

R

E N

DI

DI

R

O S

E D

R

O S

E D

DI

R

E N

DI

R

E N

DI

DI

R

O S

E D

R

O S

E

R4AO

R4AC

R4A

R4BO

R4BC

VALVE

R4B

R

E N

DI

R

E N

DI

DI

R

O S

E D

DI

R

E N

DI

R

E N

DI

DI

R

O S

E D

DI

R

O S

E D

R

O S

R5AO

R5AC

R5A

R5BO

R5BC

VALVE

R5B

R

E N

DI

R

E N

DI

DI

R

O S

E D

DI

R

E N

DI

R

E N

DI

DI

R

O S

E D

DI

R

O S

E D

R

O S

I3AO

I3BC

I3BO

I3BC

VALVE

I3A

VALVE

I3B

I3

E N

DI

E N

DI

DI

O S

E D

O S

E D

DI

E N

DI

E N

DI

DI

O S

E D

O S

E D

DI

A

B

I4AO

I4AC

VALVE

I4A

I4BO

I4BC

VALVE

I4B

I4

E N

DI

E N

DI

DI

O S

E D

O S

E D

DI

E N

DI

E N

DI

DI

O S

E D

O S

E

I5AO

VALVE

I5A

DI

I5

E N

DI

E N

DI

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI603.dwg

9:48:29 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M I

EI603

T C

H L

IN

E

M A

T C

H L

IN

E

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI604.dwg

9:50:14 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

FUEL PUMP-1

F L

O W

F L

O W

F L

O W

F L

O W

S T

A R

T

D

IS

A B

L E

S T

A R

T

D

IS

A B

L E

S T

A T

O F F

S T

A T

O F F

F L

O W

F L

O W

F L

O W

F L

O W

S T

A R

T

D

IS

A B

L E

S T

A R

T

D

IS

A B

L E

S T

A T

O F F

S T

A T

O F F

F L

O W

F L

O W

F L

O W

F L

O W

S T

A R

T

D

IS

A B

L E

S T

A R

T

D

IS

A B

L E

S T

A T

O F F

S T

A T

O F F

LG

1B

LG

2B

LG

3B

S S S

DI DI DIDI

DIDIDIDIDI

DI

DI

DIDIDIDI

DIDIDI DO

DODO

DO

DO

DO

3A

LR

2A

LR

3A

LG

2A

LG

1A

LR

1A

LG

HOA

3B

HS

MC

HOA

2B

HOA

1B

FS

FS 3

HA

3A

HS

HA

2A

HS

HA

1A

FS1

R

E S

S U

R E

AI

PS

ESO

VALVE

ESO

VALVE

ESO

VALVE

F S I-

S E

P A

R A

T O

R

F

IL

T E

R

F S I-

S E

P A

R A

T O

R

F

IL

T E

R

F S I-

S E

P A

R A

T O

R

F

IL

T E

R

FP-1

FUEL PUMP-2

FP-2

FUEL PUMP-3

FP-3

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

H

IG

H

L O

W

L O

W

VALVE

OUTLET

DI DI DI DI DI DI

DIDIDIDIDIDI

O P

E N

O P

E N

DI

DI

LSLL

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

L O

W

DI DI

O S

E

O S

E

E

E N

INLET

10882

OPERATING TANK

I5AO

I5AC

VALVE

I5A

I5BO

I5BC

VALVE

I5B

E N

DI

E N

DI

DI

O S

E D

DI

O S

E D

E N

DI

E N

DI

O S

E D

DI

O S

E D

DI

DI DI DI

I11O

I11C

VALVE

I11 I12O

I12C

I12

R10O

R10C

R9O

R9C

DIDI

DI

R

E N

DI

R

E N

DI

DI

VALVE

R10

VALVE

R9

DI

R

O S

E D

R

O S

E D

DI

DI DIDI

O S

E D

O S

E D

DI

DI

DI

E N

E N

PLC IN PCP

SYSTEM-2

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

MCC

E N

DI

E N

DI

DI

O S

E D

DI

O S

E D

DI

E N

DI

E N

DI

DI

O S

E D

DI

O S

E D

DI

LG

4B

LG

5B

FS5

5A

HS

HA

4A

FS4

T

A R

T

D

IS

A B

L E

S T

A R

T

D

IS

A B

L E

S T

A T

O F F

S T

A T

O F F

DI

DI

DO

DO

4A

LR

4A

LG

HOA

4B

FP-4

FUEL PUMP-4 FUEL PUMP-5

FP-5

F L

O W

F L

O W

F L

O W

F L

O W

DI

DI

DI

DI

S T

A R

T

D

IS

A B

L E

S T

A R

T

D

IS

A B

L E

S T

A T

O F F

S T

A T

O F F

DI

DI

DO

DO

5A

LR

5A

LG

HOA

5B

L

O W

F L

O W

F L

O W

F L

O W

DI

DI

DI

DI

AIRFIELD

TANKS

TO OPER

I6O

I6C

VALVE

E N

E N

DI

O S

E D

I7

O S

E

I7O

I7C

VALVE

E N

E N

DI

O S

E D

O S

E

I10O

I10C

VALVE

I10

E N

DI

E N

DI

O S

E D

DI

O S

E D

DI

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI604.dwg

9:50:14 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M I

EI604

T C

H L

IN

E

M A

T C

H L

IN

E

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI605.dwg

9:50:52 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

IN PCP

SYSTEM-2 PLC

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

MCC

IN PCP

SYSTEM-2 PLC

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

SS

FILL STANDS

TO TRUCK

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

VALVE (D/FV)

DEFUEL/FLUSH

(BPCV)

CONTROL VALVE

BACKPRESSURE

VALVE (PCV)

PRESSURE CONTROL

DO DO DO DO

DODODODO

P R

E S

S U

R E

R

E S

S U

R E

R

E S

S U

R E

A2

PIT

O P

E N

M O

V

O P

E N

M O

V

C L

O S

E

M O

V

C L

O S

E

M O

V

DO

DODO

DO

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

DO

DO

SS

SS

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

E N

E R

G

IZ

E

D E

E N

E R

G

IZ

E

DO

DO

TEST PANEL

TO TIGHTNESS

M

DO

DO DO

DO

C L

O S

E

M O

V

O P

E N

M O

V

C L

O S

E

M O

V

O P

E N

M O

V

M

FILL STANDS

FROM TRUCK

PIT

TEST PANEL

TO TIGHTNESS

P R

E S

S U

R E

AI

O P

E N

M O

V

O P

E N

M O

V

C L

O S

E

M O

V

DO

DO

DO

M

O P

E N

L E

K

V

O P

E N

L E

V

C L

O S

E

L E

V

C L

O S

E

L E

V

DO

DO

DO

DO

O P

E N

L E

V

O P

E N

L E

V

C L

O S

E

L E

V

C L

O S

E

L E

V

DO

DO

DO

DO

M

DO

DO DO

DO

C L

O S

E

M O

V

O P

E N

M O

V

C L

O S

E

M O

V

O P

E N

M O

V

F

IL

T E

R

S E

P A

R A

T O

R

F

IL

T E

R

S E

P A

R A

T

LEVEL

WATER

HIGH

LEVEL

WATER

HIGH

S E

P A

R A

T O

R

F

IL

T E

R

LEVEL

WATER

HIGH

PIPELINE

FROM COMM.

TO OFF LOADS

R E

C E

IP

IG

T E

R

H

T E

R R

E C

E

R E

C E

T E

R

H

T E

R R

E C

E

E

C E

T E

R

H

T E

R R

E C

E

R6O

R6C

R7O

R7C

ZS TO OFF LOADS

E N

E N

DO

DO

O S

E D

O S

E D

DO

DO

E N

E N

DO

DO

O S

E D

O S

E D

DO

R8O

R8C

E N

E N

DO

DO

O S

E D

O S

E D

DO

DO

VALVE

R8

VALVE

R6

VALVE

R7

P

P

S T

A T

O F F

S T

A T

O F F

DI

DI DI DI

S T

A T

O F F

S T

A T

O F F

DI

OFFLOAD PUMP#1

OFFLOAD PUMP#2

F L

O W

F L

O W

F L

O W

F L

O W

DIDI

DIDI

F L

O W

F L

O W

F L

O W

F L

O W

DIDI

DIDI

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI605.dwg

9:50:52 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M I

EI605

T C

H L

IN

E

M A

T C

H L

IN

E

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI606.dwg

9:51:28 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

PRODUCT RECOVERY TANK (PRT)

S T

A T

E N

C L

O S

E D

S T

A T

E N

C L

O S

E D

S T

A T

O F F

S T

A T

O F F

START/STOP

TO PUMPHOUSE

FROM PUMPHOUSE

O P

E N

C L

O S

E D

O P

E N

C L

O S

E D

L E

A K

L E

A K

P O

W

A T

U S

P O

W

A T

U S

C P

U

C P

U

C P

U

C P

U

E

S T

S E

T

E

S T

O P

SAFETY CIRCUIT

E

S T

A T

U S

E

S T

A T

U S

H

IG

H

H

V E

L

H

IG

H

H

V E

L

IN

P

L E

C T

S

Y S

IN

P

L E

C T

S

Y S

M O

L E

C T

A

U T

O

M O

L E

C T

O

F F

M O

L E

C T

F

L U

S H

L E

L E

C T

L E

L E

C T

IN

P

L E

C T

S

Y S

IN

P

L E

C T

S

Y S

M O

L E

C T

A

U T

O

M O

L E

C T

O

F F

M O

L E

C T

F

L U

S H

L E

L E

C T

L E

L E

C T

P

A

E R

M O

S T

A T

P

A

E R

M O

S T

A T

E M

E R

G

C

W

E M

E R

G

C

W

RELAY

DETECTION

LEAK

VALVE (OV)

OVERFILL

PUMP (FTP)

FUEL TRANSFER

P

DI DI DI DI

DIDIDIDIDIDIDIDI

DIDIDIDIDI

DI

DI

DI

DI

DIDIDI

DIDI

DI

DI DI

DI DODO

DODODO

TS

SS

HS

SS

HS

PB

HS

PB

YSS

SS

HSLG

LG

LW

XY

YY

EY

HOA

I-1

30A

LR

30A

LG

P

O W

O W

P

O W

O W

M O

L E

C T

T E

S T

M O

L E

C T

T E

S T

H

V E

L

H

V E

L

DI

DI

(PUMP ROOM)

PUMPHOUSE

SWITCH IN

SHOWER FLOW

EMERGENCY

L E

L E

C T

L E

L E

C T

DI

DI

MCC

IN PCP

SYSTEM-2 PLC

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

MCC

IN PCP

SYSTEM-2 PLC

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

MCC

IN PCP

SYSTEM-2 PLC

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

O F

O W

O W

O F

O W

O W

SWITCH (OFFLOADS)

SHOWER FLOW

EMERGENCY

S T

A T

O F F

S T

A T

O F F

LG

5B

DI

DI

5A

LR

5A

LG

ON-OFF

5B

FS5

5A

HS

RP-1

PRT PUMP-1

(AT PUMPHOUSE)

START/STOP

I-2

O F F

L O

M P

N

O F F

L O

M P

N

O F F

L O

M P

N

O F F

L O

M P

N

(OFFLOADS)

MC CONTACT

PUMP #1

OFFLOAD

(OFFLOADS)

MC CONTACT

PUMP #2

OFFLOAD

FILL STANDS

TO TRUCK

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI606.dwg

9:51:28 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M I

EI606

T C

H L

IN

E

M A

T C

H L

IN

E

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI607.dwg

9:51:58 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

ALARM ANNUNCIATOR

MCC

PLC IN PCP

SYSTEM-2

PLC IN PCP

SYSTEM-1

PANEL (PCP)

PUMP CONTROL

F P

IL

U R

E

F P

IL

U R

E

F P

IL

U R

E

F P

IL

U R

E

F P

IL

U R

E

F P

IL

U R

E

F P

IL

U R

E

F P

IL

U R

E

P .R

T A

H

H

IG

H

P .R

T A

V

L V

E

P .R

T A

V

L V

E

P .R

T A

A K

P .R

T A

A K

E M

E R

G E

N

O P

E M

E R

G E

N

O P

P

M P

E R

A T

U R

E

P

M P

E R

A T

U R

E

ALARM ANNUNCIATOR

T A

W

T A

H

T A

H

H

IG

H

T A

W

T A

H

T A

H

H

IG

H

T A

W

T A

H

T A

H

H

IG

H

T A

W

T A

H

T A

H

H

IG

H

ACKNOWLEDGE

RESET

P .R

T A

H

H

IG

H

S Y S

T E

M

IL

U R

E

S Y S

T E

M

IL

U R

E

S Y S

T E

M

IL

U R

E

S Y S

T E

M

IL

U R

E

DO DO DO DO DO DO DO DO DO DO DO DO DO DO DO DO DO

DODODODODODODODODODODODODODODODODO

PB

HS

PB

AA

XA

TAH

YSA

ZA

LAHH

LAH

LAL

LAH LAHH

LAHH

FA

O W

O

F F

L O

A D

O W

P

U M

P R

O O

M

O W

O

F F

L O

A D

O W

P

U M

P R

O O

M

DO DO

DODO

S Y S

T E

M

IL

U R

E

S Y S

T E

M

IL

U R

E

S Y S

T E

M

IL

U R

E

S Y S

T E

M

IL

U R

E

DO DO

DODO

P .R

T A

H

P .R

T A

H

T A

W

L O

W

T A

W

L O

W

T A

W

L O

W

T A

W

L O

W

T A

W

T A

H

T A

H

H

IG

H

T A

W

T A

DO DO DO DO

LAH LAHH

T A

W

L O

W

DO

T A

W

L O

LAL LAHH

T A

H

H

IG

H

T A

W

T A

W

L O

DO

LAHH

DO

T A

H

H

IG

H

T A

W

T A

H

T A

H

H

IG

H

T A

W

T A

H

DO DO DO DO

T A

W

L O

W

DO

T A

W

L O

W

DO DO DO

T A

H

H

IG

H

T A

W

T A

H

DO

T A

W

L O

W

DO DO DO

T A

H

H

IL

U R

E

O P

IL

U R

E

O P

IL

U R

E

O P

IL

U R

E

DO DO

DODO

P

IL

U R

E

F P

IL

U R

E

DO

DO

.S

T E

R

F .S

T E

R

T E

R

F .S

T

T E

R

F .S

T

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EI607.dwg

9:51:58 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E I6

.d w g

M R

M

P F

W

P

N T

R O

L S

Y S

T E

M I

EI607

T C

H L

IN

E

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EL101.dwg

10:06:03 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EL101.dwg

10:06:03 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E

L .d w g

M R

M

P F

W

P

M P

H O

U S

E L

IG

H T

IN

G P

L A

EL101

3. CONTROL OF EXHAUST FAN IS WITH OCCUPANCY SENSOR SWITCH.

ALLOWS.

2. LIGHTING CONTACTOR FOR EXTERIOR LIGHTING. LOCATE IN SPACE AS ROOM

NFPA 101.

1. PHOTOLUMINESCENT GREEN EXIT SIGNS LOCATED IN ROOM 101, TYPE "G". INSTALL AS REQUIRED BY

KEY NOTES:__

0 4' 8'2'

N

B1

PUMPHOUSE LIGHTING PLAN

SCALE: 1/4" = 1 '- 0"

S a

S b

1" C a

3S a

3S b

1" C

1" C

PA-2

PA-3

abba abba abba abba

3S b

3S a

#10s

#10s

B1

B1

E

M T-2

D

S

C

PC

#10

#10 #10

#10

#10

C

C

C

F

S b

S a

C

S O S

S

OS

S O S

S O S

S

OS

#10s a aa b

OS

PA-30,32

LCA

PA-35

PA-33

PA

A A1

AAA

F

A1

A1

A1

A1

PUMP ROOM

ROOM

CONTROL

a

A a

A1 b b b b b b b bb

A A1 A A

A1

1" C1" C1" C

1" C

1" C

MDS

PA

PB

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EL501.dwg

9:55:47 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

J U

L Y

F

IE

L D N

U M

B E

R

F

IL

E N

A M

E

A N

S I

D

W -1

-R -0

ADVERTISEMENT

S A

C R

A M

E N

T O

C A

L

IF

O R

N

IA

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

O

P T

IO

N A

L F

IE

L D

H

IL

L A

F B

U T

R E

P L

A C

E P

O L F

A C

IL

IT

IE

S

P N

D E

S C

H O

L D

E N

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

N U

E

O M

A H

A D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

SACRAMENTO DISTRICT

\\nwofpcadd01\AEC_WS_001\HU05\40000 Design Products\CAD_BIM\_Sheets\HU05EL501.dwg

9:55:47 AM 6/20/2018 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript

E

L .d w g

M R

M

P F

W

P

H T

IN

G D

E T

A

IL

EL501

LITHONIA SERIES CSXW LED OR AN APPROVED EQUIVALENT.

MANUFACTUER REFERENCE:

RATED FOR -30°C MINIMUM AMBIENT.

SUITABLE FOR WET LOCATIONS WHEN MOUNTED WITH THE LENSES DOWN.

LUMINAIRE - IP65 RATED.

LIGHT ENGINES ARE IP66 RATED.

CSA CERTIFIED TO U.S. AND CANADIAN STANDARDS.

LISTINGS:

UNIVERSAL MOUNTING PLATE WITH INTEGRAL MOUNTING SUPPORT ARMS.

INSTALLATION:

NON-TEXTURED FINISH.

COLOR SHALL BE DARK BRONZE.

ZINC-INFUSED THERMOSET POWDER COAT FINISH WITH MINIMUM 3 MILS THICKNESS.

FINISH:

DIMENSIONS: 7 1/8" HEIGHT X 16 3/8" WIDTH X 9 5/16" DEPTH

TO KEEP OUT MOISTURE AND DUST, WITH AN IP65 RATING FOR THE LUMINAIRE.

DIE-CAST DOOR FRAME, FULLY GASKETED WITH A ONE-PIECE SOLID SILICONE GASKET

SINGLE-PIECE DIE-CAST ALUMINUM HOUSING.

PRECISION-MOLDED ACRYLIC LENSE FOR WALL-MOUNT APPLICATIONS.

CONSTRUCTION:

SURGE PROTECTION SHALL MEET A MINIMUM CATEGORY B (PER ANSI/IEEE C62.41.2).

POWER SOURCE POWER FACTOR >90%, THD <20%.

RATED LIFE SHALL BE 100,000 HOURS AT 25°C.

CONTROLLED BY MOTION SENSOR TO BE PROVIDED WITH THE LIGHT FIXTURE.

OF 90 MINUTES.

INTEGRAL BATTERY RATED FOR -20 TO 60 DEGREE C FOR A MINIMUM DURATION

120 VOLT OPERATION.

LIGHT SOURCE SHALL BE 30 HIGH-EFFICACY LEDS.

ELECTRICAL:

ZERO UPLIGHT.

LIGHT SOURCE - 4000K WITH 70 CRI.

NEMA TYPE IV DISTRIBUTION.

7000 LUMENS .

OPTICS:

FEATURES:

FEATURES

SHIELDING: CLEAR TEMPERED GLASS

DRIVER: DRIVER HAS 1.5kV SURGE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.