* - MINIMUM OVERHANG FROM EDGE OF COOKING
EQUIPMENT TO END OF HOOD MUST BE 6"RSN F
R
L I STED
CM
US
Intertek
HANGER BRACKET DETAIL A-A
9/16" HOLE FOR 1/2"
THREADED ROD
(RODS AND HARDWARE
BY CONTRACTOR)
1/
2"
2 1/2"
BY MANUFACTURER
FULLY WELDED TO VENTILATOR
HANGER BRACKETS
12 GA. STN. STL.
1/2" DIA. BY 6'-0" LONG PLATED
STEEL HANGER RODS AND BOLTS
FURNISHED BY CONTRACTOR
NOT TO SCALE
INSTALLATION INFORMATION
GENERAL NOTES
THE MANUFACTURER SHALL MEET THE
FOLLOWING VENTILATOR TESTING,
LISTING AND APPROVAL STANDARDS:
NOTE:
CONTRACTOR NOTE:
Z
Z
EXHAUST AIR REQUIREMENTS:
EXHAUST FAN REQUIREMENTS:
INSTALLATION:
CONSTRUCTION:
NATIONAL SANITATION FOUNDATION
NATIONAL FIRE PROTECTION ASSOCIATION
ETL, INTERTEK
THE BOCA NATIONAL MECHANICAL CODE
STANDARD MECHANICAL CODE (SBCCI)
UNIFORM BUILDING CODE (ICBO)
UNIFORM MECHANICAL CODE
INTERNATIONAL MECHANICAL CODE (IMC)
FIRE PROTECTION:
PLAN
SECTION Z-Z
ELEVATION
ELECTRICAL NOTES:
120V, 60HZ, 1PH, 0.16 K.W. FROM MELINK SYSTEM
SYM QTY
E
D
DESCRIPTION
120V, 60HZ, 1PH, 0.72 K.W. CONNECTED LOAD
ROUGH-IN SCHEDULE
4 REQUIRED
ALL HOODS SHALL INCLUDE AN 18 GAUGE
STAINLESS STEEL WRAPPER ENCLOSING THE
AREA FROM THE TOP OF THE HOOD CANOPY
AND EXTENDING 2" ABOVE THE FINISHED CEILING
5'-9"
3"
(4) HANGER
BRACKETS
(SEE DETAIL A-A)
8'-0"
4'-0"
NOT TO SCALE
D
SYSTEM #1
OPTIC
SENSOR
SYSTEM #1
EXHAUST AIR
TEMP. SENSOR
6'-8" A.F.F.
NOT TO SCALE
5'-9"
2'-0"
8"
ACCESS
PANEL
UVC LIGHTING
POWER SUPPLY
AND CONTROLS(2) RECESSED
FLUORESCENT
(48") LIGHT
FIXTURES
3"
10"
SLOT TYPE
GREASE CARTRIDGES
UV TYPE STN. STL.
GREASE EXTRACTOR
UV LIGHT
CASSETTE
REMOVABLE
STN./STL.
GREASE CUP
1'-0"*
ITEM #69
NOT TO SCALE
STN.\STL.
GREASE CUP
SYSTEM #1
EXHAUST AIR
TEMP. SENSOR
ITEM #69
1'-0"*
2'-10 1/2"
2'-6"3'-0"
STN./STL
FINISHED BACK
STN./STL
FINISHED BACK
E
SYSTEM #1
CANOPY
TEMP. SENSOR
VENTILATOR TO BE SHIPPED IN (1) UNIT.
ALL PLUMBING AND ELECTRICAL DISCONNECTED
FOR SHIPMENT. RECONNECTED IN FIELD UNDER
DIVISION 22 AND DIVISION 26.
ALLOW SUFFICIENT ACCESS TO BRING VENTILATOR INTO
SERVERY AREA. MAXIMUM VENTILATOR DIMENSIONS 8'-0" LONG
x 5'-9" WIDE x 32 1/2" HIGH ESTIMATED TOTAL HANGING WEIGHT:
840 LBS.
1. EXHAUST C.F.M. BASED ON 350 C.F.M. PER LINEAR FOOT.
2. EXHAUST STATIC PRESSURE IS 1.60" W.G. AT DUCT TAKE-OFF COLLAR. TOTAL
DUCT STATIC MUST BE ADDED. STATIC BASED ON OPERATION AT MEAN SEA
LEVEL.
3. DUCT SIZE BASED ON 1,800 F.P.M.
1. TYPE - INDUCED DRAFT, SQUIRREL CAGE, BACKWARD INCLINED BLADES,
EXHAUST FAN DISCHARGE SHOULD BE VERTICAL, AWAY FROM AIR INTAKES.
FAN FURNISHED BY OTHERS.
2. EXHAUST FAN MUST BE FURNISHED WITH A MAGNETIC STARTER WITH 120
VOLT HOLDING COIL. STARTER FURNISHED UNDER DIVISION 23.
1. VENTILATORS TO BE INSTALLED IN ACCORDANCE WITH ALL CODES.
CONTRACTORS MUST REVIEW APPLICABLE CODES WITH CODE AUTHORITIES
BEFORE APPROVING DRAWINGS FOR FABRICATION. SPECIAL ATTENTION
MUST BE GIVEN TO CODE REGULATIONS RELATIVE TO CLEARANCES FROM
SURROUNDING COMBUSTIBLE CONSTRUCTION (WALL, CEILINGS, ETC.).
2. VENTILATORS ARE NOT TO BE INSTALLED IN AREAS MEANT TO HANDLE
ENVIRONMENTAL AIR.
1. VENTILATORS TO BE MANUFACTURED IN STRICT ACCORDANCE WITH SPECIFICATIONS.
2. VENTILATORS CONSTRUCTED OF 18 GA. STAINLESS STEEL.
TOTAL EXHAUST : 5,600 C.F.M.
10" X 22" EXHAUST DUCTS
2,800 C.F.M. EACH @ 1.60" S.P.
IN ACCORDANCE WITH RECOMMENDATION OF NATIONAL FIRE
PROTECTION ASSOCIATION'S NFPA NO. 96 "VAPOR REMOVAL FROM
COOKING EQUIPMENT"
STANDARD #2 - "FOOD SERVICE EQUIPMENT"
TESTED UNDER STANDARD U.L. 710 "EXHAUST HOODS FOR
COMMERCIAL COOKING EQUIPMENT".
SECTION 507 - COMMERCIAL KITCHEN HOODS AND KITCHEN
VENTILATION SYSTEMS
CHAPTER 5 - KITCHEN EXHAUST EQUIPMENT
SECTION 504 - COMMERCIAL HOODS
SECTION 507 - COMMERCIAL KITCHEN HOODS
EXCLUDES CODE #507.2.1.1
1. LIGHT FIXTURES, VAPORPROOF, U.L. LISTED, FURNISHED, INSTALLED
AND WIRED TO J-BOX D BY MANUFACTURER. RECONNECTED ON
JOBSITE UNDER DIVISION 26.
2. LIGHT SWITCH FOR LIGHT FIXTURE WITH 120 VOLTS A.C. SERVICE
BY MANUFACTURER. LIGHT SWITCH (SYSTEM #1 KEYPAD) LOCATED ON THE
SYSTEM #1 ENCLOSURE.
3. UVC LIGHT CONTROL BOX FURNISHED AND INSTALLED BY MANUFACTURER.
120V SUPPLY AND INTERLOCK WIRING TO EACH JUNCTION BOX E UNDER
DIVISION 26.
1. SURFACE FIRE PROTECTION PROVIDED AND INSTALLED BY MANUFACTURER
(ANSUL R-102).
2. CAUTION: SURFACE FIRE PROTECTION SYSTEM INSTALLATION MUST BE
COORDINATED WITH MANUFACTURER TO PREVENT SYSTEMS INTERFERENCE
WITH VENTILATOR'S OPERATION/PERFORMANCE. IMPROPER INSTALLATION
MAY VOID LISTINGS OF THE EQUIPMENT.
3. IMPORTANT NOTE: NFPA 96 REQUIRES THAT ALL GAS AND ELECTRIC
COOKING EQUIPMENT THAT IS PROTECTED BY A SURFACE FIRE
PROTECTION SYSTEM MUST AUTOMATICALLY SHUT OFF UPON ACTIVATION OF
THE SYSTEM.
CONTRACTOR MUST VERIFY THE EXACT DIMENSION OF THE COOKING
EQUIPMENT FROM EITHER THE WALL OR FROM THE FRONT OF THE
HOOD, SO MANUFACTURER MAY PROPERLY LOCATE THE FIRE PROTECTION
NOZZLES AT TIME-OF-FABRICATION IN THE FACTORY. IF EQUIPMENT
IS NOT LOCATED AS SHOWN AND THE DRAWING IS APPROVED FOR
FABRICATION, THEN NOZZLES MUST BE RELOCATED AT THE
EXPENSE OF OTHERS.
ALLOW SUFFICIENT ACCESS ON TOP OF VENTILATOR TO
SERVICE COMPONENTS AND UTILITIES
4"
Solutions for the Culinary Arts
Foodservice Consultants Studio, Inc.
3420 Pump Road, #158 Henrico, VA 23233 Phone/Fax: 804-550-2090 www.FoodserviceStudio.com
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
200112
QF512
VOLUME 4
H O
O D
D E T
AI
LS
IT
EM
A
IT
B A
R
RA
C K
S
CO
M
PL
EX
P H
A
SE
D
IN
IN
G
F A
C I L
IT
Y
N O
R
FO
LK
D
I S
TR
IC
T
N O
R
FO
LK
, V
A
D W
H
SK
W
D W
H
LJ
H
A
PR
PR
O
JE
C T
N U
M
BE
R
C O
N
TR
AC
T
N O
Q F 5
F O R
T L E
E, V
I R G
IN
I A
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
P
ER
A
M
EN
D M
EN
T
J
U N
File details come from the government source that posted it. Updated .