VOL_2_EL701_3JUN2016.pdf

PDF 240 KB Posted

Attached to
AIT Barracks- Phase III, Ft. Lee, Virginia Federal contract opportunity
Solicitation number
W91236-16-R-0010
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

VOL 2_EL701_3JUNE2016

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks- Phase III, Ft. Lee, Virginia, newest first.
File Type Posted
W91236-16-R-0010-0008.pdf PDF
W91236-16-R-0010-0007.pdf PDF
VOL_2_A-601_3JUN2016.pdf PDF
VOL_3_EP601_3JUN2016.pdf PDF
VOL_2_E-001_3JUN2016.pdf PDF
VOL_3_EL701_3JUN216.pdf PDF
BARRACKS_SPECIFICATION_14_21_23_-_ELECTRIC_TRACTION_PASSENGER_ELEVATORS_3JUN2016.pdf PDF
VOL_2_M-601_3JUN2016.pdf PDF
VOL_2_EP701_3JUN2016.pdf PDF
VOL_3_E-001_3JUN2016.pdf PDF
VOL_2_EP104_3JUN2016.pdf PDF
VOL_2_EP601_3JUN2016.pdf PDF
VOL_2_EP703_3JUN2016.pdf PDF
VOL_3_EP701_3JUN2016.pdf PDF
VOL_2_M-001_3JUN2016.pdf PDF
VOL_3_EL502_3JUN2016.pdf PDF
VOL_3_EP102_3JUN2016.pdf PDF
W91236-16-R-0010-0005.pdf PDF
VOL_3_A-601_3JUN2016.pdf PDF
Am_4_-_Attach_02_VOL_2_A-002_26MAY2016.pdf PDF
Am_4_-_Attach_22_VOL_3_S-501_26MAY2016.pdf PDF
synthetic_turf_spec.pdf PDF
Am_4_-_Attach_18_VOL_3_S-105_26MAY2016.pdf PDF
Am_4_-_Attach_13_VOL_3_A-504_26MAY2016.pdf PDF
Am_4_-_Attach_05_VOL_2_A-507_26MAY2016.pdf PDF
Am_4_-_Attach_21_VOL_3_S-108_26MAY2016.pdf PDF
Am_4_-_Attach_17_VOL_3_S-102_26MAY2016.pdf PDF
Am_4_-_Attach_12_VOL_3_A-318_26MAY2016.pdf PDF
W91236-16-R-0010-0004.pdf PDF
25May2016_Site_Visit_Roster.pdf PDF
Am_4_-_Attach_01_VOL_1__CS101-103_26MAY2016.pdf PDF
VOL_2_EP601_20May2016.pdf PDF
VOL_3_P-001_20May2016.pdf PDF
W91236-16-R-0010-0003.pdf PDF
DFAC FFE Package_16May2016.pdf PDF
BARRACKS_SPECS_VOL2_16May2016.pdf PDF
DFAC_SPECS_VOL1_16May2016.zip ZIP file
BARRACKS_SPECS_VOL3_16May2016.pdf PDF
VOL 4_LEE_DFAC_16May2016.pdf PDF
VOL 1_LEE_SITE_16May2016.pdf PDF
VOL 2_LEE_BCOF_600_16May2016.pdf PDF
H.01.04_Volume4DFACPlans_21April2016.zip ZIP file
H.01.01_LEEAITBARRACKSCOMPLEXPH3VOL3300PN_21April2016.zip ZIP file
A.07.23_solicitation_9May2016.pdf PDF
H.01.04_LEE_VOLUME_1_SITE(Progress_Submission).zip ZIP file
H.01.04_BARRACKS_Specifications21April2016.zip ZIP file
H.01.04__Drainage_Report_21April2016.zip ZIP file
H.01.04_Volume2600PersonBarracks_21April2016.zip ZIP file
H.01.04_LEE_VOLUME_3_300MAN_(ProgressSubmission).zip ZIP file
H.01.04_LEE_VOLUME_2_600_MAN_BARRACKS(Progress_Submission).zip ZIP file
Show all 50

AIT Barracks- Phase III, Ft. Lee, Virginia has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WIRING LEGEND:

INPUT POWER

2#12AWG

1-WAY RF COMMUNICATION

2#18AWG

BUS:

2#16 CONDUCTOR

NON-PLENUM OR 2#16

CONDUCTOR PLENUM RATED.

WALL CONTROL

ADJUST

CEILING MOUNT

OCCUPANCY/

VACANCY SENSOR

*DEVICE IS SURFACE-MOUNTED

AND BATTERY POWERED, DOES

NOT REQUIRE POWER FEED

SENSE

WIRELESS PIR WALL

MOUNTED OCCUPANCY/

VACANCY SENSOR

*DEVICE IS SURFACE-MOUNTED

AND BATTERY POWERED, DOES

NOT REQUIRE POWER FEED

WIRELESS PIR CORNER

MOUNTED OCCUPANCY/

VACANCY SENSOR

*DEVICE IS SURFACE-MOUNTED

AND BATTERY POWERED, DOES

NOT REQUIRE POWER FEED

WIRELESS PIR HALL

MOUNTED OCCUPANCY/

VACANCY SENSOR

*DEVICE IS SURFACE-MOUNTED

AND BATTERY POWERED, DOES

NOT REQUIRE POWER FEED

24V AC/DC

INPUT

HVAC

INTEGRATION

CONTROL MODULE

WITH (1) CONTACT CLOSURE

OUTPUT

CONTROL

120V/277V

INPUT FEED

TO BALLASTS/LED DRIVERS

(32 MAX PER POWPAK)

CONTROL MODULE

WITH (1) CONTACT CLOSURE

OUTPUT

120/277 INPUT FEED

FROM DISTRIBUTION

PANEL

DIGITAL BALLAST

120/277 INPUT FEED

FROM DISTRIBUTION

PANEL

DRIVER

120V/277V

DIGITAL LOOP

SCALE: NOT TO SCALE

12VDC

POWER SUPPLY

(PLUGS INTO DUPLEX

RECEPTACLE)

SINGLE GANG

BACKBOX

SINGLE GANG

BACKBOX

TRANSMITTER

RECEIVER

INFRARED PARTITION

SWITCH

CONTACT-CLOSURE

INTERFACE

SCALE: NOT TO SCALE

2#18AWG

3#18AWG

9'-5 57/64"

F.F.

0' - 0"

FIRST FLOOR

0' - 0"

PROVIDE FOUR LIGHT FIXTURES

EQUALLY SPACED APART, AND

A DRIVER. LIGHT FIXTURE SHALL BE

FLUSH MOUNTED, LED BUTTON PUCK

LIGHT FIXTURE WITH WHITE FINISH,

2.25" DIAMETER, 0.875" HEIGHT,

6 LEDS, 2700K, AND 4.8 WATTS.

LIGHT FIXTURES SHALL BE POWERED

FROM CIRCUIT H13-18.

SCALE: NOT TO SCALE

EL701

E L

E C

T R

I C

A L

I G

H T

I N

G

C O

N T

R O

S

R

I S

E R

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U

M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

F I

E

N

M

E

I S

S U

E

D

A T

E

F I

U M

B E

R

1 2 3 4 5

D

C

B

A

A I T

B

R

R A

C K

S

C

O M

P L

E X

P H

A S

E

M

A N

N O

R F

O L

K

D

I S

T R

I C

T

N O

R F

O L

K

V

A

S C

H

S C

H

K B

A

P R

P R

O J E

C

C O

N T

R A

C

M A

R K

D E

S C

R I P

T I O

N D

A T

E

S C

H

VOLUME 2

F O

E

V

I R

G I N

I A

R

E V

I S

D

P

M E

N D

M E

N T

J U

N

File details come from the government source that posted it. Updated .