ELEVATION, SECTION OR DETAIL SYMBOL
SHEET NUMBER WHERE ELEVATION,
SECTION OR DETAIL IS DRAWN
NUMBER INDICATES SECTION
LETTER INDICATES ELEVATION OR DETAIL
E-401
CIRCUIT BREAKER SIZE
NUMBER OF POLES FOR
THE CIRCUIT BREAKER
SIZE OF THE CONDUIT FOR PHASE,
NEUTRAL, AND GROUND CONDUCTORS
SIZE OF GROUND CONDUCTORSSIZE OF PHASE/NEUTRAL CONDUCTORS
NUMBER OF SETS OF THE
PHASE/NEUTRAL AND GROUND
CONDUCTORS, AND CONDUITS
NUMBER OF PHASE/
NEUTRAL CONDUCTORS
NUMBER OF GROUND CONDUCTORS
CIRCUITING CB
SETS NO SIZE C P A
1 2/1 12/12 3/4" 1 20
MCB MAIN CIRCUIT BREAKER
MAIN LUG ONLYMLO
NON-FUSED
PHASE
POLE
NOT IN CONTRACT
NF
PH
P
NIC
AMPEREA
AFF
AHU
AWG AMERICAN WIRE GAUGE
AIR HANDLING UNIT
ABOVE FINISHED FLOOR
RECEPTACLE
PVC
RECEPT
SPLIT CIRCUIT
SUPPLY FAN
SC
SF
POLY VINYL CHLORIDE
SUPPRESSOR
TELEVISIONTV
TVSS
UNDERGROUND
UNIT HEATER
VOLTS
UG
UH
UON
V
UNLESS OTHERWISE NOTED
TRANSIENT VOLTAGE SURGE
CONDUITC
EC
EF
EWC
EMT ELECTRICAL METALLIC TUBING
ELECTRIC WATER COOLER
EMPTY CONDUIT
EXHAUST FAN
FACP
FLA
FCU
GFCI GROUND FAULT
CIRCUIT INTERRUPTER
FIRE ALARM CONTROL PANEL
FULL LOAD AMPS
FAN COIL UNIT
WIRE
TRANSFORMER
W
WP
XFMR
WEATHERPROOF
GROUND
GFI
GRS
GND
HP
HID
KAIC
KWH
KVA
THOUSAND AMP INTERRUPTING
CAPACITY, RMS SYMMETRICAL
HIGH INTENSITY DISCHARGE
GALVANIZED RIGID STEEL
GROUND FAULT INTERRUPTER
KILOVOLT AMPERE
KILOWATT HOUR
HORSEPOWER
LIGHTINGLTG
THOUSAND CIRCULAR MILSKCMIL
PASSIVE INFRAREDPIR
AFG ABOVE FINISHED GRADE
ABBREVIATIONS
TELECOMMUNICATIONS MAINTMGB
GROUNDING BUSBAR
GFP GROUND FAULT PROTECTION
ROOF DRAINRD
US UNTRA SONIC
C
S
S
E
M
J
P
S
11A
PA
M
LIGHTING
HIGH INTENSITY DISCHARGE (H.I.D), LED OR COMPACT FLUORESCENT LIGHTING FIXTURE
INDICATES BRACKET, WALL MOUNTED FIXTURE).
FLUORESCENT LIGHTING FIXTURE
LOWER CASE LETTERS INDICATE SWITCH CONTROL ASSOCIATION WHERE USED.
a
LIGHTING FIXTURE TYPE MARK. SEE LIGHTING FIXTURE SCHEDULE ON SHEET EL501.
FLUORESCENT EMERGENCY LIGHTING FIXTURE.
WALL MOUNTED FIXTURE). EMERGENCY LIGHTING FIXTURE INDICATED BY HALF
HATCH OR BY CAPITAL LETTER "E" AFTER LIGHTING FIXTURE TYPE MARK. LOWER
CASE LETTERS INDICATE SWITCH CONTROL ASSOCIATION WHERE USED. SEE
LIGHTING FIXTURE SCHEDULE NOTES SHEET EL501. SEE WIRING DIAGRAM ON
SHEET EL601.
HIGH INTENSITY DISCHARGE (H.I.D), FLUORESCENT OR COMPACT FLUORESCENT
EMERGENCY LIGHTING FIXTURE
EXIT LIGHTING FIXTURE. ARROW, WHEN USED, INDICATES DIRECTION, TYPE "E1", UON.
INDICATES LIGHT FIXTURE OR JUNCTION BOX FOR LIGHT FIXTURE PROVIDED WITH
KITCHEN EQUIPMENT
POWER DEVICES
DUPLEX CONVENIENCE RECEPTACLE WITH INTERNAL GROUND FAULT
PROTECTION. 20 A, 125 VAC. MOUNT 18" AFF UON. "WP" WHEN USED INDICATES
PROVIDE WEATHERPROOF COVER.
CEILING DUPLEX RECEPTACLE, 20 A, 125 VAC.
DUPLEX RECEPTACLE AS NOTED ABOVE BUT, MOUNT 48" AFF OR 6" ABOVE
BACKSPLASH OR COUNTER TOP WHERE COUNTER IS INDICATED. PROVIDE GFCI TYPE
WHERE LOCATED WITH-IN 6' OF SINK.
SPECIAL PURPOSE RECEPTACLE. MOUNT 18" AFF UON. REFER TO PLANS AND EQUIPMENT
SCHEDULES FOR CONFIGURATION.
EQUIPMENT CONNECTION AS NOTED
MOTOR CONNECTION AS INDICATED
JUNCTION BOX
WP
DISTRIBUTION
PANELBOARD - 208Y/120V
PANELBOARD - 480Y/277V
DRY TYPE TRANSFORMER, SIZE AS INDICATED.
DUPLEX CONVENIENCE RECEPTACLE, 20 A, 125 VAC, MOUNT 18" AFF UON.
SINGLE POLE SWITCH, 20 A, 120/277 V. MOUNT +48" AFF.
THREE-WAY SWITCH, 20 A, 120/277 V. MOUNT +48" AFF.
EXTERIOR PHOTOCELL, ON-AT-DUSK/OFF-AT-DAWN, MOUNTED ON ROOF. SEE DETAIL
ON SHEET EL503
20 AMP SINGLE POLE WALL SWITCH WITH RED PILOT LIGHT.
OCCUPANCY SENSOR, PIR TECHNOLOGY (UON), MOTION ONLY,WIRELESS, CEILING
MOUNTED.
SEE GENERAL NOTE G9. SUBSCRIPT WHEN USED, INDICATES THE FOLLOWING:
"E" INDICATES EXTENDED RANGE OPTION
"DT" INDICATES DUAL TECHNOLOGY OPTION
"H" INDICATES LOW TEMP/HIGH HUMIDITY OPTION
WALL SWITCH OCCUPANCY SENSOR, PIR TECHNOLOGY (UON), MOTION ONLY, WIRELESS,
MOUNT AT 48" AFF. SUPERSCRIPT WHEN USED, INDICATES THE FOLLOWING:
"H" INDICATES LOW TEMP/HIGH HUMIDITY OPTION
"D" INDICATES DUAL TECHNOLOGY - BOTH PIR AND US
WIRE, CONDUIT AND RACEWAY
GROUND ROD WITH INSPECTION PIT
DRIVEN GROUND ROD
GROUNDING
HOMERUNS TO PANEL. PANEL AND CIRCUIT DESIGNATIONS AS INDICATED.
CONDUIT TURNED UP.
CONDUIT TURNED DOWN.
MISCELLANEOUS
NOTE REFERENCE NUMBER.
REFER TO FEEDER SCHEDULE.
ROOM NUMBER.
CEILING MOUNTED SPEAKER. "WP" INDICATES WEATHERPROOF SPEAKER.
NUMBER INDICATES ZONE/GROUPING DESIRED.
PA SYSTEM RACK
PA SYSTEM MIC
EQUIPMENT CONNECTIONS
MAGNETIC MOTOR CONTROLLER (CONTROLLER FURNISHED WITH EQUIPMENT)
VARIABLE FREQUENCY DRIVE CONNECTION (DRIVE FURNISHED WITH EQUIPMENT)
MOTOR RATED SWITCH WITH OVERLOADS. SWITCH WITH PILOT LIGHT SINGLE POLE
SWITCH 20 A, 120/277, PROVIDE WITH WEATHERPROOF BOX AND PLATE
KITCHEN EQUIPMENT TAG. SEE SHEETS EP605 THRU EP607
FOR KITCHEN EQUIPMENT SCHEDULE.
FUSED DISCONNECT SWITCH, 600V IN NEMA 1 ENCLOSURE, UON. PROVIDE
RK-5 FUSES.
ENCLOSED CIRCUIT BREAKER IN NEMA 1 ENCLOSURE, 22 KAIC, UON.
BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT RUN CONCEALED IN CEILING,
WALL, FLOOR, OR ABOVE SUSPENDED CEILING UON. SEE PANELBOARD
SCHEDULES FOR WIRE AND CONDUIT SIZES. PROVIDE CONDUCTOR COUNT AS
REQUIRED FOR OCCUPANCY SENSORS, EMERGENCY LIGHTING, 3 AND 4-WAY
SWITCHING ETC..
UNDERGROUND SERVICE CONDUIT
UNDERGROUND FEEDER CONDUIT
GFCI
QUAD RECEPTACLE, 20A, 125VAC MOUNT 18" AFF, UON, 'GFCI' WHEN USED INDICATES
INTERNAL GROUND FAULT PROTECTION.
FOUR-WAY SWITCH, 20 A, 120/277 V. MOUNT +48" AFF.
ELECTRICAL LEGEND
A1
T
P
OS
WP
M
UGS
UG
WP
HLI-1,3,5
J
S
S
S
S
S
INDICATES BRACKET, WALL MOUNTED FIXTURE).(
INDICATES BRACKET,(
INDICATES BRACKET, WALL MOUNTED FIXTURE).(
INDICATES BRACKET, WALL MOUNTED FIXTURE). FILLED-IN QUADRANT(s) OF
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
WH WATT-HOUR METER
CURRENT TRANSFORMER
TRANSFORMER
VFD
O
S WALL MOUNTED SPEAKER (MOUNTED 12'-6" AFF UON). "WP" INDICATES
WEATHERPROOF SPEAKER. NUMBER INDICATES ZONE/GROUPING DESIRED.
WP
a
TELEVISION RECEPTACLE. DUPLEX, 20 A, 125 VAC. MOUNT 7'-6" AFF UON. COORDINATE
EXACT LOCATION WITH ARCHITECTURAL DRAWINGS.TV
S B
S
WIRELESS SWITCH, 1-BUTTON ON/OFF WITH BI-LEVEL LIGHTING CONTROL.
MOUNT AT 48" AFF.
WIRELESS SWITCH, 1-BUTTON ON/OFF. MOUNT AT 48" AFF.
A1E
SEE LIGHTING SCHEDULE NOTES ON SHEET EL501.
SYMBOL INDICATES NUMBER AND ORIENTATION OF ILLUMINATED FACES.
GFCI
OS
INDICATES BRACKET, WALL MOUNT FIXTURE 8'-0" AFF, UON).(
AUTOMATIC DUPLEX CONVENIENCE RECEPTACLE, 20 A, 125 VAC, MOUNT 18" AFF UON.
A
Sd WIRELESS SWITCH, 1-BUTTON ON/OFF WITH RAISE/LOWER CONTROL. MOUNT AT 48" AFF.
SARCH WIRELESS WALLSTATION, 5-BUTTON WITH ON/OFF AND RAISE/LOWER CONTROL. MOUNT AT
48" AFF.
QUAD RECEPTACLE, 20A, 125VAC FLOORBOX.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
376273
E-001
VOLUME 2
E L
EC
TR
IC
AL
L
EG
E N
D A
N D
A
BB
R
EV
I A
TI
O N
S
A
IT
B A
R
RA
CK
S
CO
M
PL
EX
PH
A
SE
6 0
M
A N
N O
R
FO
LK
D
I S
TR
IC
T
N O
R
FO
LK
, V
A
SC
H
SC
H
SC
H
KB
A
PR
PR
O
JE
C T
N U
M
BE
R
C O
N
TR
AC
T
N O
E- 0 0
1-
F O R
T L E
E, V
I R G
IN
I A
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
P
ER
A
M
EN
D M
EN
T
J
U N
| Sheets |
| E-001 - ELECTRICAL LEGEND AND ABBREVIATIONS |
| EL502 - LIGHTING FIXTURE DETAILS |