VOL_3_E-001_3JUN2016.pdf

PDF 84 KB Posted

Attached to
AIT Barracks- Phase III, Ft. Lee, Virginia Federal contract opportunity
Solicitation number
W91236-16-R-0010
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

VOL 3_E-001_3JUNE2016

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks- Phase III, Ft. Lee, Virginia, newest first.
File Type Posted
W91236-16-R-0010-0008.pdf PDF
W91236-16-R-0010-0006.pdf PDF
VOL_2_EL701_3JUN2016.pdf PDF
VOL_3_M-602_3JUN2016.pdf PDF
VOL_2_EP702_3JUN2016.pdf PDF
VOL_3_EP702_3JUN2016.pdf PDF
VOL_3_M-601_3JUN2016.pdf PDF
VOL_4_M-601_3JUN2016.pdf PDF
VOL_4_P-502_3JUN2016.pdf PDF
VOL_3_EP703_3JUN2016.pdf PDF
VOL_3_EP102_3JUN2016.pdf PDF
W91236-16-R-0010-0005.pdf PDF
VOL_3_A-601_3JUN2016.pdf PDF
Hazard_Assessment_Survey_2013.pdf PDF
VOL_4_QF603_3JUN2016.pdf PDF
VOL_4_QF512_3JUN2016.pdf PDF
VOL_2_M-602_3JUN2016.pdf PDF
VOL_2_EL502_3JUN2016.pdf PDF
Am_4_-_Attach_10_VOL_3_A-101_26MAY2016.pdf PDF
Am_4_-_Attach_08_VOL_2_S-003_26MAY2016.pdf PDF
Am_4_-_Attach_23_VOL_4_A-101_26MAY2016.pdf PDF
Am_4_-_Attach_07_VOL_2_G-002_26MAY2016.pdf PDF
Am_4_-_Attach_03_VOL_2_A-101_26MAY2016.pdf PDF
Amendment_4_Breakout.pdf PDF
Am_4_-_Attach_15_VOL_3_G-002_26MAY2016.pdf PDF
Am_4_-_Attach_04_VOL_2_A-112_26MAY2016.pdf PDF
Am_4_-_Attach_20_VOL_3_S-105B_26MAY2016.pdf PDF
Am_4_-_Attach_06_VOL_2_A-551_26MAY2016.pdf PDF
Am_4_-_Attach_19_VOL_3_S-105A_26MAY2016.pdf PDF
Am_4_-_Attach_24_VOL_4_A-103_26MAY2016.pdf PDF
Am_4_-_Attach_14_VOL_3_A-551_26MAY2016.pdf PDF
Am_4_-_Attach_09_VOL_2_S-108_26MAY2016.pdf PDF
Am_4_-_Attach_25_VOL_4_A-510_26MAY2016.pdf PDF
VOL_3_EP601_20May2016.pdf PDF
DAYS_BASE_ACCESS_Template_.xlsx XLSX spreadsheet
Amendment_Details_3_20May2016.pdf PDF
VOL 1_LEE_SITE_20May2016.pdf PDF
Utility_Coordination_20May2016.pdf PDF
01_33_29_20May2016.pdf PDF
DFAC_SPECS_VOL2_16May2016.pdf PDF
BARRACKS_SPECS_VOL3_16May2016.pdf PDF
W91236-16-R-0010-0002.pdf PDF
BARRACKS_SPECS_VOL1_16May2016.pdf PDF
W91236-16-R-0010-00001.pdf PDF
VOL 3_LEE_BCOF_300_16May2016.pdf PDF
H.01.04_LEE_VOLUME_4_DFAC_(ProgressSubmission).zip ZIP file
H.01.04_DFAC_Specifications_21April2016.zip ZIP file
H.01.04_LEE_VOLUME_3_300MAN_(ProgressSubmission).zip ZIP file
H.01.04_LEE_VOLUME_2_600_MAN_BARRACKS(Progress_Submission).zip ZIP file
H.01.04_Volume1SITEPlans_21April2016.zip ZIP file
Show all 50

AIT Barracks- Phase III, Ft. Lee, Virginia has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELEVATION, SECTION OR DETAIL SYMBOL

SHEET NUMBER WHERE ELEVATION,

SECTION OR DETAIL IS DRAWN

NUMBER INDICATES SECTION

LETTER INDICATES ELEVATION OR DETAIL

E-401

CIRCUIT BREAKER SIZE

NUMBER OF POLES FOR THE

CIRCUIT BREAKER

SIZE OF CONDUIT FOR THE PHASE,

NEUTRAL, AND GROUND CONDUCTORS

SIZE OF THE GROUND CONDUCTORS

NUMBER OF SETS OF

THE PHASE/NEUTRAL

AND GROUND

CONDUCTORS AND

CONDUITS

NUMBER OF PHASE/NEUTRAL

CONDUCTORS

NUMBER OF GROUND CONDUCTORS

SIZE OF THE PHASE/NEUTRAL CONDUCTORS

CIRCUITING CB

SETS NO. SIZE C P A

1 2/1 12/12 3/4" 1 20

MCB MAIN CIRCUIT BREAKER

MAIN LUG ONLYMLO

NON-FUSED

PHASE

POLE

NOT IN CONTRACT

NF

PH

P

NIC

AMPEREA

AFF

AHU

AWG AMERICAN WIRE GAUGE

AIR HANDLING UNIT

ABOVE FINISHED FLOOR

RECEPTACLE

PVC

RECEPT

SPLIT CIRCUIT

SUPPLY FAN

SC

SF

POLY VINYL CHLORIDE

SUPPRESSOR

TELEVISIONTV

TVSS

UNDERGROUND

UNIT HEATER

VOLTS

UG

UH

UON

V

UNLESS OTHERWISE NOTED

TRANSIENT VOLTAGE SURGE

CONDUITC

EC

EF

EWC

EMT ELECTRICAL METALLIC TUBING

ELECTRIC WATER COOLER

EMPTY CONDUIT

EXHAUST FAN

FACP

FLA

FCU

GFCI GROUND FAULT

CIRCUIT INTERRUPTER

FIRE ALARM CONTROL PANEL

FULL LOAD AMPS

FAN COIL UNIT

WIRE

TRANSFORMER

W

WP

XFMR

WEATHERPROOF

GROUND

GFI

GRS

GND

HP

HID

KAIC

KWH

KVA

THOUSAND AMP INTERRUPTING

CAPACITY, RMS SYMMETRICAL

HIGH INTENSITY DISCHARGE

GALVANIZED RIGID STEEL

GROUND FAULT INTERRUPTER

KILOVOLT AMPERE

KILOWATT HOUR

HORSEPOWER

LIGHTINGLTG

THOUSAND CIRCULAR MILSKCMIL

PASSIVE INFRAREDPIR

AFG ABOVE FINISHED GRADE

ABBREVIATIONS

TELECOMMUNICATIONS MAINTMGB

GROUNDING BUSBAR

GFP GROUND FAULT PROTECTION

ROOF DRAINRD

US UNTRA SONIC

C

S

S

E

M

J

P

S

11A

PA

M

LIGHTING

HIGH INTENSITY DISCHARGE (H.I.D) OR LED OR COMPACT FLUORESCENT LIGHTING FIXTURE

INDICATES BRACKET, WALL MOUNTED FIXTURE).

FLUORESCENT LIGHTING FIXTURE

LOWER CASE LETTERS INDICATE SWITCH CONTROL ASSOCIATION WHERE USED.

a

LIGHTING FIXTURE TYPE MARK. SEE LIGHTING FIXTURE SCHEDULE ON SHEET EL501.

FLUORESCENT EMERGENCY LIGHTING FIXTURE.

WALL MOUNTED FIXTURE). EMERGENCY LIGHTING FIXTURE INDICATED BY HALF

HATCH OR BY CAPITAL LETTER "E" AFTER LIGHTING FIXTURE TYPE MARK. LOWER

CASE LETTERS INDICATE SWITCH CONTROL ASSOCIATION WHERE USED. SEE

LIGHTING FIXTURE SCHEDULE NOTES SHEET EL501. SEE WIRING DIAGRAM ON

SHEET EL601.

HIGH INTENSITY DISCHARGE (H.I.D), FLUORESCENT OR COMPACT FLUORESCENT

EMERGENCY LIGHTING FIXTURE

EXIT LIGHTING FIXTURE. ARROW, WHEN USED, INDICATES DIRECTION, TYPE "E1", UON.

INDICATES LIGHT FIXTURE OR JUNCTION BOX FOR LIGHT FIXTURE PROVIDED WITH

KITCHEN EQUIPMENT

POWER DEVICES

DUPLEX CONVENIENCE RECEPTACLE WITH INTERNAL GROUND FAULT

PROTECTION. 20 A, 125 VAC. MOUNT 18" AFF UON. "WP" WHEN USED INDICATES

PROVIDE WEATHERPROOF COVER.

CEILING DUPLEX RECEPTACLE, 20 A, 125 VAC.

DUPLEX RECEPTACLE AS NOTED ABOVE BUT, MOUNT 48" AFF OR 6" ABOVE

BACKSPLASH OR COUNTER TOP WHERE COUNTER IS INDICATED. PROVIDE GFCI TYPE

WHERE LOCATED WITH-IN 6' OF SINK.

SPECIAL PURPOSE RECEPTACLE. MOUNT 18" AFF UON. REFER TO PLANS AND EQUIPMENT

SCHEDULES FOR CONFIGURATION.

EQUIPMENT CONNECTION AS NOTED

MOTOR CONNECTION AS INDICATED

JUNCTION BOX

WP

DISTRIBUTION

PANELBOARD - 208Y/120V

PANELBOARD - 480Y/277V

DRY TYPE TRANSFORMER, SIZE AS INDICATED.

DUPLEX CONVENIENCE RECEPTACLE, 20 A, 125 VAC, MOUNT 18" AFF UON.

SINGLE POLE SWITCH, 20 A, 120/277 V. MOUNT +48" AFF.

THREE-WAY SWITCH, 20 A, 120/277 V. MOUNT +48" AFF.

EXTERIOR PHOTOCELL, ON-AT-DUSK/OFF-AT-DAWN, MOUNTED ON ROOF. SEE DETAIL

ON SHEET EL503

OCCUPANCY/VACANCY SENSOR, PIR TECHNOLOGY (UON), MOTION ONLY, WIRELESS,

CEILING MOUNTED.

SEE GENERAL NOTE G9. SUBSCRIPT WHEN USED, INDICATES THE FOLLOWING:

"E" INDICATES EXTENDED RANGE OPTION

"DT" INDICATES DUAL TECHNOLOGY OPTION

"H" INDICATES LOW TEMP/HIGH HUMIDITY OPTION

WALL SWITCH OCCUPANCY/VACANCY SENSOR, PIR TECHNOLOGY (UON), MOTION ONLY,

WIRELESS, MOUNT AT 48" AFF. SUPERSCRIPT WHEN USED, INDICATES THE FOLLOWING:

"H" INDICATES LOW TEMP/HIGH HUMIDITY OPTION

"D" INDICATES DUAL TECHNOLOGY - BOTH PIR AND US

WIRE, CONDUIT AND RACEWAY

GROUND ROD WITH INSPECTION PIT

DRIVEN GROUND ROD

GROUNDING

HOMERUNS TO PANEL. PANEL AND CIRCUIT DESIGNATIONS AS INDICATED.

CONDUIT TURNED UP.

CONDUIT TURNED DOWN.

MISCELLANEOUS

NOTE REFERENCE NUMBER.

REFER TO FEEDER SCHEDULE.

ROOM NUMBER.

CEILING MOUNTED SPEAKER. "WP" INDICATES WEATHERPROOF SPEAKER.

NUMBER INDICATES ZONE/GROUPING DESIRED.

PA SYSTEM RACK

PA SYSTEM MIC

EQUIPMENT CONNECTIONS

MAGNETIC MOTOR CONTROLLER (CONTROLLER FURNISHED WITH EQUIPMENT)

VARIABLE FREQUENCY DRIVE CONNECTION (DRIVE FURNISHED WITH EQUIPMENT)

MOTOR RATED SWITCH WITH OVERLOADS. SWITCH WITH PILOT LIGHT SINGLE POLE

SWITCH 20 A, 120/277, PROVIDE WITH WEATHERPROOF BOX AND PLATE

KITCHEN EQUIPMENT TAG. SEE SHEETS EP605 THRU EP607

FOR KITCHEN EQUIPMENT SCHEDULE.

FUSED DISCONNECT SWITCH, 600V IN NEMA 1 ENCLOSURE, UON. PROVIDE

RK-5 FUSES.

ENCLOSED CIRCUIT BREAKER IN NEMA 1 ENCLOSURE, 22 KAIC, UON.

BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT RUN CONCEALED IN CEILING,

WALL, FLOOR, OR ABOVE SUSPENDED CEILING UON. SEE PANELBOARD

SCHEDULES FOR WIRE AND CONDUIT SIZES. PROVIDE CONDUCTOR COUNT AS

REQUIRED FOR OCCUPANCY SENSORS, EMERGENCY LIGHTING, 3 AND 4-WAY

SWITCHING ETC..

UNDERGROUND SERVICE CONDUIT

UNDERGROUND FEEDER CONDUIT

GFCI

FOUR-WAY SWITCH, 20 A, 120/277 V. MOUNT +48" AFF.

ELECTRICAL LEGEND

A1

T

OS

WP

M

UGS

UG

WP

HLI-1,3,5

J

S

S

S

S

INDICATES BRACKET, WALL MOUNTED FIXTURE).(

INDICATES BRACKET,(

INDICATES BRACKET, WALL MOUNTED FIXTURE).(

INDICATES BRACKET, WALL MOUNTED FIXTURE). FILLED-IN QUADRANT(s) OF

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

WH WATT-HOUR METER

CURRENT TRANSFORMER

TRANSFORMER

VFD

O

S WALL MOUNTED SPEAKER (MOUNTED 12'-6" AFF UON). "WP" INDICATES

WEATHERPROOF SPEAKER. NUMBER INDICATES ZONE/GROUPING DESIRED.

WP

a

TELEVISION RECEPTACLE. DUPLEX, 20 A, 125 VAC. MOUNT 7'-6" AFF UON. COORDINATE

EXACT LOCATION WITH ARCHITECTURAL DRAWINGS.TV

S

Sd

WIRELESS SWITCH, 1-BUTTON ON/OFF. MOUNT AT 48" AFF.

WIRELESS SWITCH, 1-BUTTON ON/OFF WITH RAISE/LOWER CONTROL. MOUNT AT 48"

AFF.

A1E

SEE LIGHTING SCHEDULE NOTES ON SHEET EL501.

SYMBOL INDICATES NUMBER AND ORIENTATION OF ILLUMINATED FACES.

OS INDICATES BRACKET, WALL MOUNT FIXTURE 8'-0" AFF, UON).(

K KIRK KEY INTERLOCK

QUAD RECEPTACLE, 20A, 125VAC MOUNT 18" AFF, UON, 'GFCI' WHEN USED INDICATES

INTERNAL GROUND FAULT PROTECTION.GFCI

AUTOMATIC DUPLEX CONVENIENCE RECEPTACLE, 20 A, 125 VAC, MOUNT 18" AFF UON.

A

S

B WIRELESS SWITCH, 1-BUTTON ON/OFF WITH BI-LEVEL LIGHTING CONTROL.

MOUNT AT 48" AFF.

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

280212

E-001

VOLUME 3

E L

EC

T R

IC

AL

L

EG

E N

D , A

BB

R

E V

IA

TI

O

N S, A N

D N

O

TE

S

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

SC

H

SC

H

SC

H

KB

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

E- 0 0

1-

F O R

T L E

E, V

I R G

IN

I A

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

P

ER

A

M

EN

D M

EN

T

J

U N

Sheets
E-001 - ELECTRICAL LEGEND, ABBREVIATIONS, AND NOTES