UT Ammo Dwg 8-21-09 pgs 40-181.pdf

PDF 43 MB Posted

Attached to
Construction of an Ammunitions Supply Point Facility Federal contract opportunity
Solicitation number
W911YP-09-B-0002
Issued by
Department of the Army Utah Army National Guard

About this file

Updated Drawings (100 ) Set 3 of 3

View the file

Other files for this federal contract opportunity

Other files attached to Construction of an Ammunitions Supply Point Facility, newest first.
File Type Posted
ASP Addendum 0010.doc DOC document
ASP Davis Bacon UT080039.pdf PDF
ASP Davis Bacon UT080060.pdf PDF
ASP RFIs Addendum 0009.doc DOC document
ASP 01360 —
ASP 08315 Sliding Blast Resistant Door Addendum 0009.doc DOC document
ASP Addendum 0009 Utah National Guard Seed Mix.doc DOC document
ASP Addendum 0009.doc DOC document
ASP Addendum No 0009 - Notice to Bidders.doc DOC document
Davis Bacon UT080038 —
ASP Addendum 0008.doc DOC document
ASP Addendum 0008 RFIs.doc DOC document
Davis Bacon UT080059 —
ASP Addendum 0007.doc DOC document
ASP Addendum 0007 Drawings Specifications.pdf PDF
ASP A-E's Addendum 3 Notice to Bidders.pdf PDF
ASP Addendum 0006.doc DOC document
ASP A-E's TOC-ADM3.pdf PDF
ASP geotechnical report.pdf PDF
BID SCHEDULE ASP CW.Revised Add 0006.doc DOC document
ASP Addendum 0006.doc DOC document
W911YP-09-B-0002-0005.doc DOC document
W911YP-09-B-0002-0004.doc DOC document
BID SCHEDULE ASP CW.Revised.doc DOC document
W911YP-09-B-0002-0002 ASP addendum.doc DOC document
UT Ammo Dwg 8-21-09 pgs 1-28.pdf PDF
ASP Site Visits Contractors.pdf PDF
UT Ammo Dwg 8-21-09 pgs 29-39.pdf PDF
J A Sole Source Telecommunications ASP.doc DOC document
Utah Ammo Specs 8-21-09.pdf PDF
W911YP-09-B-0002-0001 ASP Addendum 001.doc DOC document
Utah ARNG Camp Williams Ammo Storage Point - 95 Design Submittal PDF BINDER - 7-28-09.pdf PDF
W911YP-09-B-0002 Ammunitions Suppy Point —
20090729_UTAH_ASP_95 Plans.pdf PDF
Utah ARNG Camp Williams Ammo Storage Point - 95 Design Submittal PDF PKG - 7-28-09.pdf PDF
Show all 35

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPE QTY WATTS VOLTS VA TYPE HEIGHT

X1

COBRA HEAD AREA LIGHT

HOUSING: DIECAST ALUMINUM

REFLECTOR: ANNODIZED ALUMINUM

LENS: FLAT GLASS REFLECTOR

LUMARK

HP / RL / DL / 3 / 250 / MT / OA / PA 1016

WITH PS200S060 BRACKET FOR WOOD

POLE

HPS 1 250

MULTIVOLT

ELECTRONIC

240 295 POLE MOUNT +30'-0" AFG

X2

COBRA HEAD AREA LIGHT

HOUSING: DIECAST ALUMINUM

REFLECTOR: ANNODIZED ALUMINUM

LENS: FLAT GLASS REFLECTOR

LUMARK

HP / RL / DL / 3 / 250 / MT / OA / PA 1016

WITH PS200S060 BRACKET FOR WOOD

POLE

HPS 1 250

MULTIVOLT

ELECTRONIC

480 295 POLE MOUNT +30'-0" AFG

NOTES:

FIXTURE

1. MANUFACTURER AND MODEL NOS. LISTED ARE INTEDED ONLY AS A REFERENCE TO REQUIRED

PERFORMANCE AND SALIENT CHARACTERISTICS. OTHER MANUFACTURERS SHALL BE ALLOWED

AS APPROVED EQUAL.

MOUNTING

P SERIES - INDUSTRIAL TURRET

LAMP

LUMINAIRE SCHEDULE

MANUFACTURER AND

LUMINAIRE TYPE

DESCRIPTION

DWG

ID

TYPE

NOTESBALLAST

PRIMARY

FEEDER SIZE REMARKS

TAP1 12.47KV 1PH-3W 120/240V 1PH-3W 75

SEE POWER

RISER B/00E201

A

TSP1 12.47KV 3PH-3W 480Y/277V 3PH-4W 300

SEE POWER

RISER B/00E201

3 PH

TDP1 12.47KV 1PH-3W 120/240V 1PH-3W 25

SEE POWER

RISER B/00E201

B

TIP1 12.47KV 1PH-3W 120/240V 1PH-3W 25

SEE POWER

RISER B/00E201

C

TBP1 12.47KV 1PH-3W 120/240V 1PH-3W 50

SEE POWER

RISER B/00E201

B

TE1 12.47KV 1PH-3W 120/240V 1PH-3W 50

SEE POWER

RISER B/00E201

C

TRANSFORMER SCHEDULE

DESIGNATION PRIMARY VOLTAGE SECONDARY VOLTAGE KVA

PHASE

CONNECTION

P1 2

CELL 1: 3#1/0, 15KV TYPE MV-90 PRIMARY CABLE

CELL 2: SPARE 48" 1 2

P2 NA ADMINISTRATION BUILDING SERVICE ENTRANCE 48" 3 4

P3 NA SIRE BUILDING SERVICE ENTRANCE 48" 3 4

P4 NA LOADING DOCK SERVICE ENTRANCE 48" 3 4

P5 NA INERT STORAGE SERVICE ENTRANCE 48" 3 4

P6 NA BREAKDOWN STORAGE SERVICE ENTRANCE 48" 3 4

P7 NA ECM 1-5 SERVICE ENTRANCE 48" 3 4

P8 NA ECM 6-11 SERVICE ENTRANCE 48" 3 4

P9 NA FEEDER FROM GENERATOR 48" 3 4

P10 NA

BRANCH CIRCUITS IN 1 1/4" CONDUIT

SITE LIGHTING: 2#6, 1#6 GND

CAMERA POWER: (3) 2#10, 1#10 GND 36" 6

P11 NA

BRANCH CIRCUITS IN 1" CONDUIT

SITE LIGHTING: 2#6, 1#6 GND

CAMERA POWER: (2) 2#10, 1#10 GND 36" 7

P12 NA

BRANCH CIRCUITS IN 1" CONDUIT

SITE LIGHTING: 2#6, 1#6 GND

CAMERA POWER: 2#10, 1#10 GND 36" 7

P13 NA

BRANCH CIRCUITS

SITE LIGHTING: 2#6, 1#6 GND -1"C

CAMERA POWER: 2#10, 1#10 GND - 3/4"C 36" 8

P14 NA

BRANCH CIRCUIT

SITE LIGHTING: 2#6, 1#6 GND -1"C 36" 8

P15 NA

BRANCH CIRCUITS IN 1 1/4" CONDUIT

SITE LIGHTING: 2#6, 1#6 GND

CAMERA POWER: (4) 2#10, 1#10 GND 36" 6

P16 2

CELL 1: 1#1/0, 15KV TYPE MV-90 PRIMARY CABLE

CELL 2: SPARE 48" 1 2

NOTES:

1. REFER TO C/00E501 FOR DUCTBANK DETAIL.

2. PROVIDE PULL ROPE IN SPARE CELL(S).

3. SEE INDIVIDUAL PANEL SCHEDULE (LOCATED WITH BUILDING SHEETS) FOR FEEDER SIZE.

4. CONDUIT SHALL BE SCHEDULE 40 PVC ENCASED IN 3" OF CONCRETE. TRANSITION TO RGS IN

BUILDING/ABOVE SLAB.

5. SEE POWER RISER DIAGRAM B/00E201 FOR FEEDER SIZE.

6. CONDUIT SHALL BE SCHEDULE 40 PVC BELOW GRADE. TRANSITION TO EMT INSIDE BUILDING/

ABOVE SLAB.

7. CONDUIT SHALL BE SCHEDULE 40 PVC.

8. CONDUIT SHALL BE SCHEDULE 40 PVC BELOW GRADE. TRANSITION TO RGS ABOVE GRADE

ON POLE.

NOTES

POWER CIRCUIT SCHEDULE

DESIGNATOR DESCRIPTION

NO. OF

CELLS

BURIAL

DEPTH

C1 NA 36"

C2 2

CELL 1:

CELL 2:

VOICE SERVICE CABLE - 100 PAIR COPPER

DATA SERVICE CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE 36" 1 2

C3 2

CELL 1:

CELL 2:

VOICE SERVICE CABLE - 100 PAIR COPPER

DATA SERVICE CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

CAMERA VIDEO - (1) 1 PAIR 62.5/125 MM MULTIMODE FIBER

OPTIC CABLE IN 3/4" INNERDUCT 36" 1

C4 2

CELL 1:

CELL 2:

VOICE SERVICE CABLE - 100 PAIR COPPER

DATA SERVICE CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

CAMERA VIDEO - (2) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 3/4" INNERDUCT 36" 1

C5 2

CELL 1:

CELL 2:

VOICE SERVICE CABLE - 100 PAIR COPPER

DATA SERVICE CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

CAMERA VIDEO - (3) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 3/4" INNERDUCT 36" 1

C6 6

CELL 1:

CELL 2:

CELL 3:

CELL 4:

CELL 5:

CELL 6:

VOICE SERVICE CABLE - 100 PAIR COPPER

DATA SERVICE CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

CAMERA VIDEO - (3) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 3/4" INNERDUCT

VOICE TRUNK CABLE - 75 PAIR COPPER

DATA TRUNK CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

CAMERA VIDEO - (7) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 1" INNERDUCT

SPARE

SPARE 36" 1 2

C7 4

CELL 1:

CELL 2:

CELL 3:

CELL 4:

VOICE TRUNK CABLE - 75 PAIR COPPER

DATA TRUNK CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

CAMERA VIDEO - (7) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 1" INNERDUCT

SPARE

SPARE 36" 1 2

C8 NA

COMM

SPARE

SERVICE ENTRANCE IN 4" C

VOICE TRUNK CABLE - 25 PAIR COPPER

DATA TRUNK CABLE - (1) 12 PAIR 62.5/125MM MULTIMODE / 6

PAIR SINGLE MODE FIBER OPTIC CABLE

4"C 36" 2 3

C9 2

CELL 1:

CELL 2:

VOICE TRUNK CABLE - 50 PAIR COPPER

CAMERA VIDEO - (7) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 1" INNERDUCT 36" 1

C10 NA

COMM SERVICE ENTRANCE IN 4" C

VOICE TRUNK CABLE - 25 PAIR COPPER 36" 3

C11 2

CELL 1:

CELL 2:

CAMERA VIDEO - (7) 1 PAIR 62.5/125MM MULTIMODE FIBER

OPTIC CABLE IN 1" INNERDUCT

SPARE 36" 1 2

C12 2

CELL 1:

CELL 2:

SPARE

SPARE 36" 1 2

C13 NA 36" 2 3

C14 2

CELL 1:

CELL 2:

VOICE TRUNK CABLE - 25 PAIR COPPER

SPARE 36" 1 2

C15 NA 36"

NOTES:

1. REFER TO D/00E501 FOR DUCTBANK DETAIL.

2. PROVIDE PULL ROPE IN SPARE CELL(S).

3. CONDUIT(S) SHALL BE SCHEDULE 40 PVC ENCASED IN 2" OF CONCRETE. TRANSITION TO RGS IN

BUILDING/ABOVE SLAB. STUB UP 8" ABOVE CONCRETE AND BUSH CONDUIT END.

4. ALL SERVICE AND TRUNK CABLES SHALL BE CONSIDERED OUTSIDE PLANT (OSP) PER SPECIFICATIONS.

CAMERA VIDEO:

(1) 1 PAIR 62.5/125MM MULTIMODE FIBER OPTIC - 3/4"C

SERVICE ENTRANCE CABLES IN 4" SCHEDULE 40 PVC:

100 PAIR COPPER VOICE SERVICE CABLE

(1) 12 PAIR 62.5/125MM MULTIMODE / 6 PAIR SINGLE MODE FIBER OPTIC

DATA SERVICE CABLE

(2) 1 1/2" SPARE CONDUITS

NOTES

TELECOMMUNICATIONS CIRCUIT SCHEDULE

DESIGNATOR

NO. OF

CELLS

BURIAL

DEPTHDESCRIPTION

D1

6" OPEN REFLECTOR DOWNLIGHT

LAMP: VERTICAL

LENS: NONE

REFLECTOR: LOW IRIDESCENT

HOUSING: GALVANIZED STEEL

PORTFOLIO

C6018E / 6001LI / TRR6 / HB26

CFQ18 1 18

PROGRAM

START

ELECTRONIC

120 21 GYPSUM CEILING

D2

7" OPEN REFLECTOR DOWNLIGHT

LAMP: HORIZONTAL

LENS: NONE

REFLECTOR: LOW IRIDESCENT

HOUSING: GALVANIZED STEEL

PORTFOLIO

C7142E / 7151LI / TRM7P / HB26

CFTT42 1 42

PROGRAM

START

ELECTRONIC

120 46 T-BAR CEILING

D3

7" OPEN REFLECTOR DOWNLIGHT

LAMP: HORIZONTAL

LENS: NONE

REFLECTOR: LOW IRIDESCENT

HOUSING: GALVANIZED STEEL

PORTFOLIO

C7126E / 7251LI / TRR7 / HB26

CFQ26 1 26

PROGRAM

START

ELECTRONIC

120 29 GYPSUM CEILING

D4

6" OPEN REFLECTOR DOWNLIGHT

LAMP: HORIZONTAL

LENS: DIFFUSE ACRYLIC

REFLECTOR: LOW IRIDESCENT

HOUSING: GALVANIZED STEEL

UL WET LOCATION

PORTFOLIO

C6132E / 6181LI2 / HB26

CFTT32 1 32

PROGRAM

START

ELECTRONIC

120 36 GYPSUM CEILING

E1

AC POWERED RED LED EXIT SIGN

HOUSING: POLYCARBONATE/WHITE

FACES: NUMBER AND CHEVERONS AS INDICATED

SURE-LITES

CCX60RWH

LED 120 4

UNIVERSAL

SEE PLANS

CEILING

L1

2'X4' LENSED TROFFER

REFLECTOR: PAINTED WHITE

LENS: #12 PATTERN ACRYLIC

HOUSING: STEEL PAINTED WHITE

METALUX

2GC8RA / 232A / UNV / ER81

F32T8/

2 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

120 59 T-BAR CEILING

L1B

2'X4' LENSED TROFFER

REFLECTOR: PAINTED WHITE

LENS: #12 PATTERN ACRYLIC

HOUSING: STEEL PAINTED WHITE

METALUX

2FC8RA / 232A / UNV / ER81

F32T8/

2 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

120 59 GYPSUM CEILING

L2

1'X4' LENSED TROFFER

REFLECTOR: PAINTED WHITE

LENS: #12 PATTERN ACRYLIC

HOUSING: STEEL PAINTED WHITE

METALUX

FC8RA / 232A / UNV / ER81

F32T8/

2 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

120 59 GYPSUM CEILING

S1

4' STRIP

HOUSING: STEEL PAINTED WHITE

COOPER

SN / 232 / UNV / ER81

F32T8/

2 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

120 59 SURFACE CEILING

W1

ARCHITECTURAL AREA LIGHT W/ARC KEEPER

LENS: CLEAR TEMPERED GLASS

REFLECTOR: SPECULAR ALZAK

HOUSING: BRONZE PAINTED DIE CAST ALUMINUM

LUMARK

HPIP / S / 70 / MT / ARC KEEPER

MED BASE

HPS70

1 70

MULTI-VOLT

MAGNETIC

120 91 WALL +9'-0" AFG 1

NOTES:

1. MOUNTING HEIGHT TO BE MEASURED FROM BOTTOM OF FIXTURE.

2. MANUFACTURERS AND MODEL NUMBERS LISTED ARE INTENDED ONLY AS A REFERENCE TO REQUIRED

PERFORMANCE AND SALIENT CHARACTERISTICS. OTHER MANUFACTURERS SHALL BE ALLOWED AS APPROVED EQUAL.

S SERIES - STRIP FLUORESCENT

L SERIES - LENSED FLUORESCENT TROFFER

LAMP

E SERIES - EXIT SIGN

D SERIES - COMPACT FLUORESCENT DOWNLIGHT

FURNISHED W/

LUMINAIRE

LUMINAIRE SCHEDULE

MANUFACTURER AND

LUMINAIRE TYPE

DESCRIPTION

DWG

ID

TYPE

NOTESBALLAST

FIXTURE MOUNTING

W SERIES - WALL MOUNT

TYPE SIZE TYPE SIZE FUSE

EF-1 EXHAUST FAN 120 1 - - 1/4 FVNR 0 CS/FD 30/1 9 - - 2#12, 1#12 GND - 3/4"C

DWH-1 DOMESTIC WATER HEATER 120 1 1.5 - - - - SFT 15/1 15 - - 2#12, 1#12 GND - 3/4"C

EWC-1 ELECTRIC WATER COOLER 120 1 - 3.7 - - - - - - 5-20P 5-20R 2#12, 1#12 GND - 3/4"C

HP-1 HEAT PUMP 240 1 - 17 - - - FD 30/2 20 - - 2#12, 1#12 GND - 3/4"C

BC-1 BLOWER COIL 240 1 - 1 - - - FD 30/2 5 - - 2#12, 1#12 GND - 3/4"C

EDH-1 ELECTRIC DUCT HEATER 240 1 17.6 - - - - FD 100/2 100 - - 2#1, 1#6 GND - 1 1/2"C

EUH-1 ELECTRIC UNIT HEATER 120 1 - 4.2 - - - - - - - - 2#12, 1#12 GND - 3/4"C 1 2

EUH-2 ELECTRIC UNIT HEATER 240 1 - 12.5 - - - FD 30/2 20 - - 2#12, 1#12 GND - 3/4"C 2 3

F-1 FURNACE 120 1 - 12 - - - SFT 15/1 15 - - 2#12, 1#12 GND - 3/4"C

F-2 FURNACE 120 1 - 12 - - - SFT 15/1 15 - - 2#12, 1#12 GND - 3/4"C

F-3 FURNACE 120 1 - 12 - - - SFT 15/1 15 - - 2#12, 1#12 GND - 3/4"C

ACCU-1 AIR COOLED CONDENSING UNIT 240 1 - 33.3 - - - FD 60/2 35 - - 2#8, 1#10 GND - 1"C

ACCU-2 AIR COOLED CONDENSING UNIT 240 1 - 10.7 - - - FD 30/2 15 - - 2#12, 1#12 GND - 3/4"C

ACCU-3 AIR COOLED CONDENSING UNIT 240 1 - 10.7 - - - FD 30/2 15 - - 2#12, 1#12 GND - 3/4"C

GENERAL EQUIPMENT SCHEDULE NOTES: REFERENCED NOTES:

A. MOUNT ALL DISCONNECTS AND STARTERS ON UNIT UNLESS INDICATED OTHERWISE. 1. PROVIDE QMARK #DPH05A-4125-TDS (OR APPROVED EQUAL) PEDESTAL HEATER.

MOUNT ALL WITH CLEARANCES AS PER NEC. COORDINATE WITH MECHANICAL. FINISH SHALL MATCH VESTIBULE DOOR FRAME. PROVIDE #PHB05-2

B. SFT = FUSIBLE SWITCH UNIT (BUSS #SSU OR APPROVED EQUAL) WITH FUSE. LEGS AND #DSH05-ECR/ECL END CAPS.

C. FVNR = FULL VOLTAGE NON-REVERSING MOTOR STARTER. 2. UNIT HAS INTEGRAL DISCONNECT AND CONTROLS. COORDINATE

D. CS/NFD, FD = COMBINATION STARTER / NON OR FUSED DISCONNECT SWITCH. REQUIREMENTS PRIOR TO ORDERING.

E. NFD OR FD = NON OR FUSED DISCONNECT SWITCH. 3. PROVIDE QMARK #MUH03-21 (OR APPROVED EQUAL) FORCED AIR HEATER.

F. ALL SWITCHES, DISCONNECTS, ETC SHALL BE LOCKABLE IN ON AND OFF POSITION. PROVIDE BRACKET FOR CEILING MOUNT.

G. ALL SWITCHES, DISCONNECTS, ETC SHALL BE NEMA 3R WHERE REQUIRED.

H. PROVIDE FUSES AS SHOWN, REVISE SIZES PER ACTUAL NAMEPLATE DATA.

I. STARTER ACCESSORIES:

1) CONTROL TRANSFORMER

2) H-O-A SWITCH

3) RED RUN LIGHT

4) 2 NC CONTACT; 2 NO CONTACTS

DISCONNECT PLUG

CONFIG

RECPT

CONFIG

FEEDER

SIZE NOTES

ELECTRICAL EQUIPMENT SCHEDULE

DEVICE DESCRIPTION VOLTAGE PH KVA FLA HP

STARTER

PANELBOARD NO: AP2

VOLTAGE: 120/240 BUS RATING: 225A ENCLOSURE: NEMA 1

PHASE: 1 MAIN OC DEVICE: 150/2 CB MOUNTING: SURFACE

WIRE: 3+GND INTERRUPTING RATING: 10 KA LOCATION: MECH RM 108

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 3#1/0, 1#6 GND - 1 1/2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 LTS BREAK,COMM,MECH,RR'S, LOCKERS 1,100 20 1 A 20 2 1,650 HP-1 2

3 LTS OPEN OFFICE, CUST SERV, CORR 500 20 1 B 1,650 4

5 EXTERIOR LIGHTS 300 20 1 A 20 2 120 BC-1 6

7 LIGHTING CONTROL PANEL 1,000 20 1 B 120 8

9 REC COMM RM 400 20 1 A 20 2 1,700 POLE LIGHTS 10

11 REC COMM RM 400 20 1 B 1,700 12

13 REC COMM RM 400 20 1 A 20 1 800 MASS NOTIFICATION CONTROL PANEL 14

15 CAMERA POWER 500 20 1 B 20 1 800 MNS POWER SUPPLY 16

17 CAMERA POWER 500 20 1 A 20 1 800 INTRUSION DETECTION CONTROL PANEL 18

19 CAMERA POWER 500 20 1 B 20 1 1,000 CCTV EQUIPMENT 20

21 DOOR LOCK POWER SUPPLIES 600 20 1 A SPACE (LEAVE BLANK) 22

23 SECURITY DESK 400 20 1 B SPACE (LEAVE BLANK) 24

25 SPARE (LEAVE BLANK;CB OFF POSITION) 20 1 A SPACE (LEAVE BLANK) 26

27 SPARE (LEAVE BLANK;CB OFF POSITION) 20 1 B 30 2 TVSS 28

29 SPARE (LEAVE BLANK;CB OFF POSITION) 20 1 A 30

LTS REC MECH MISC

CONNECTED LOAD (KVA) 5.3 1.6 3.5 6.5 240 LINE-TO-LINE VOLTS PHASE A (KVA) 8

DEMAND FACTOR 1.00 NEC 0.80 1.00 71 CONNECTED AMPS PHASE B (KVA) 9

DESIGN LOAD (KVA) 5.3 1.6 2.8 6.5 85 DESIGN AMPS

SPARE

25%

4.1

16.9

20.3

TOTAL PHASE BALANCE

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

PANELBOARD NO: AP1

VOLTAGE: 120/240 BUS RATING: 400A ENCLOSURE: NEMA 1

PHASE: 1 MAIN OC DEVICE: 400/2 CB MOUNTING: SURFACE

WIRE: 3 INTERRUPTING RATING: 14 KA LOCATION: MECH RM 108

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: YES FEEDER: (2) 3#3/0 - 1 1/2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 LTS OPEN OFF, CUST SERV 1,100 20 1 A 20 1 600 REC OPEN OFFICE 2

3 LTS OFF,BREAK,COMM,MECH,RR'S, LOCKERS 1,600 20 1 B 20 1 600 REC OPEN OFFICE 4

5 F-3 1,450 20 1 A 20 1 600 REC OPEN OFFICE 6

7 F-2 1,450 20 1 B 20 1 600 REC OPEN OFFICE 8

9 F-1 1,450 20 1 A 20 1 400 REC JAN CLOSET/ CORRIDOR 10

11 EUH-1 500 20 1 B 20 1 800 REC SUPERVISOR OFFICE 12

13 EUH-2 1,500 20 2 A 20 1 800 REC REFRIGERATOR 14

15 1,500 B 20 1 800 REC BREAK RM COUNTER , DISPOSAL 16

17 REC MECH RM 400 20 1 A 20 1 1,000 REC BREAK ROOM 18

19 DWH-1 1,500 20 1 B 20 1 800 REC RESTROOM 20

21 EDH-1 8,800 100 2 A 20 1 400 EWC 22

23 8,800 B 20 1 400 EWC 24

25 TVSS 30 2 A 20 1 600 REC CUST SERV 26

27 B 20 1 600 REC CUST SERV 28

29 REC PRINTER 600 20 1 A 800 REC MICROWAVE 30

31 REMOTE GATE 2,100 40 3 B 40 2 4,000 ACCU-1 32

33 2,100 A 4,000 34

35 2,100 B 20 2 1,300 ACCU-2 36

37 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 1,300 38

39 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 20 2 1,300 ACCU-3 40

41 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 1,300 42

43 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 20 1 700 EF-1 44

45 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 46

47 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 48

49 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 50

51 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 52

53 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 54

55 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 56

57 ATS - PANEL AP2 10,025 150 2 A - - SUBFEED BREAKER 58

59 10,265 B 60

LTS REC MECH MISC

CONNECTED LOAD (KVA) 2.7 9.4 48.0 20.9 240 LINE-TO-LINE VOLTS PHASE A (KVA) 39

DEMAND FACTOR 1.00 NEC 0.80 1.00 337 CONNECTED AMPS PHASE B (KVA) 42

DESIGN LOAD (KVA) 2.7 9.4 38.4 20.9 318 DESIGN AMPS

PHASE BALANCE

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

80.9

76.3

TOTAL

SPARE

7%

5.0

D1

6" OPEN REFLECTOR DOWNLIGHT

LAMP: VERTICAL

LENS: NONE

REFLECTOR: LOW IRIDESCENT

HOUSING: GALVANIZED STEEL

PORTFOLIO

C6018E / 6001LI / TRR6 / HB26

CFQ18/

1 18

PROGRAM

START

ELECTRONIC

277 21 GYPSUM CEILING

E1

DUAL HEAD EMERGENCY LIGHT

HOUSING: POLYCARBONATE/WHITE

BATTERY: SEALED LEAD CALCIUM

SURE-LITES

CC7SDSM

INC A LAMP 277 1

SURFACE,

WALL

+9''-0"'

E2

AC POWERED RED LED EXIT SIGN W/ BATTERY

HOUSING: POLYCARBONATE/WHITE

FACES: NUMBER AND CHEVERONS AS INDICATED

BATTERY: SEALED LEAD CALCIUM

SURE-LITES

CCX70RWHSD

LED 277 4

UNIVERSAL

SEE PLANS

CEILING

E3

AC POWERED RED LED EXIT SIGN W/BATTERY

(HAZ. LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

FACES: NUMBER AND CHEVRONS AS INDICATED

BATTERY: SEALED LEAD CALCIUM

RIG-A-LITE

XPEX / 1 / R / UC / DT / WP / EM

LED 277 4

SURFACE,

WALL

+9'-0"

E4

DUAL HEAD EMERGENCY LIGHT

(HAZ. LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

BATTERY: SEALED LEAD CALCIUM

SURE-LITES

HZU125425 INC A LAMP 277 1

SURFACE,

WALL

+9'-0"

H1

HID AREA LIGHT

HOUSING: ALUMINUM PAINTED WHITE

LENS: INJECTION MOLDED PRISMATIC

REFLECTOR: PAINTED WHITE

LUMARK

HPCL / 100 / 277

MOGUL BASE

HPS100

1 100 MAGNETIC 277 127 SURFACE CANOPY

L1

2'X4' LENSED TROFFER

REFLECTOR: PAINTED WHITE

LENS: #12 PATTERN ACRYLIC

HOUSING: STEEL PAINTED WHITE

COOPER

2GC8RA / 232A / UNV / ER81

F32T8/

2 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

277 59 T-BAR CEILING

T1

4' FLUORESCENT (HAZ. LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

RIG-A-LITE

XP265 / 4 / 3L / C

F32T8/

3 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

277 89 SURFACE CEILING

T1A

4' FLUORESCENT (HAZ. LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

RIG-A-LITE

XP265 / 4 /4L / C

F32T8/

4 32

MULTI-VOLT

PROGRAM

START

ELECTRONIC

277 119 SURFACE CEILING

W1

2' WALL MOUNT FLUORESCENT

HOUSING: BRUSHED ALUMINUM PAINTED WHITE

SPLIT DISTRIBUTION UP/DOWN

REFLECTOR: PAINTED WHITE

METALUX

BAU / 217 / UNV / ER81

F17T8/

2 17

MULTI-VOLT

PROGRAM

START

ELECTRONIC

277 30

SURFACE,

WALL

+7'-6"

W2

ARCHITECTURAL AREA LIGHT W/ EMERGENCY MR-16 SOCKET

LENS: CLEAR TEMPERED GLASS

REFLECTOR: SPECULAR ALZAK

HOUSING: BRONZE PAINTED DIE CAST ALUMINUM

LUMARK

HPIP / S / 50 / MT / EM-SC-12V

MED BASE

HPS50

1 50

MULTI-VOLT

MAGNETIC

277 76

SURFACE,

WALL

+9'-0" AFG 1,2

W3

HID AREA LIGHT (HAZ. LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

GLOBE: HIGH IMPACT RESISTANT GLASS

RIG-A-LITE

SAF / 10 / S / 27 / GG / W

MOGUL BASE

HPS100

1 100 MAGNETIC 277 127

SURFACE,

WALL

+9'-0""

W4

VAPOR PROOF COMPACT FLUORESCENT

HOUSING: NEMA 4 ALUMINUM

GLOBE: CLEAR PRISMATIC

RIG-A-LITE

VP/WB/1/13/F/MT

CFQ13/

1 13

PROGRAM

START

ELECTRONIC

277 16

SURFACE,

WALL

+9'-0""

NOTES:

1. MOUNTING HEIGHT TO BE MEASURED FROM BOTTOM OF FIXTURE.

2. PROVIDE FIXTURE WITH 12V, 35W BI-PIN MR-16 LAMP. PROVIDE 12V EMERGENCY BATTERY PACK AND CONNECT TO MR-16.

3. MANUFACTURER AND MODEL NOS. LISTED ARE INTEDED ONLY AS A REFERENCE TO REQUIRED PERFORMANCE AND

SALIENT CHARACTERISTICS. OTHER MANUFACTURERS SHALL BE ALLOWED AS APPROVED EQUAL.

FURNISHED W/

LUMINAIRE

LUMINAIRE SCHEDULE

MANUFACTURER AND

LUMINAIRE TYPE

DESCRIPTION

DWG

ID

TYPE

NOTESBALLAST

FIXTURE MOUNTING

W SERIES - WALL MOUNT

T SERIES - INDUSTRIAL TURRET

LAMP

E SERIES - EMERGENCY LIGHTING

D SERIES - COMPACT FLUORESCENT DOWNLIGHT

FURNISHED W/

LUMINAIRE

FURNISHED W/

LUMINAIRE

FURNISHED W/

LUMINAIRE

H SERIES - HID AREA LIGHT

EF-1 EXHAUST FAN 120 1 - - 1/6 - - SFT 15/1 6.25 - - 2#12, 1#12 GND - 3/4"C

EF-2,3,4,5,6 EXHAUST FAN 480 3 - - 3/4 FVNR 0 CS/FD 30/3 3.2 - - 3#12, 1#12 GND - 3/4"C 1

ACCU-1 AIR COOLED CONDENSING UNIT 208 3 - 23 - - - FD 30/3 30 - - 3#10, 1#10 GND - 1" C

BC-1 BLOWER COIL 480 3 - - 1.5 FVNR 1 CS/FD 0 15 - - 3#12, 1#12 GND - 3/4"C

B-1 BOILER 120 1 - 4 - - - SFT 15/1 5 - - 2#12, 1#12 GND - 3/4"C

UH-1 UNIT HEATER 120 1 - - 1/25 - - SFT 15/1 2 - - 2#12, 1#12 GND - 3/4"C

UH-2,3,4,5,6,

7,8,9,10,11,12,13

UNIT HEATER 120 1 - - 1/12 - - SFT 15/1 3 - - 2#12, 1#12 GND - 3/4"C 1

SF-1 SUPPLY FAN 120 1 - - 1/6 - - SFT 15/1 6.25 - - 2#12, 1#12 GND - 3/4"C

HWP-1,2 HOT WATER PUMP 480 3 - - 2 VFD 1 CS/FD 30/3 6.25 - - 3#12, 1#12 GND - 3/4"C

AC-1 AIR COMPRESSOR 480 3 - - 30 FVNR 2 CS/FD 60/3 60 - - 3#3, 1#8 GND - 1 1/4"C

AD-1 AIR DRYER 120 1 1 - - - - SFT 15/1 15 - - 2#12, 1#12 GND - 3/4"C

DWH-1 DOMESTIC WATER HEATER 120 1 - 12 - - - SFT 15/1 15 - - 2#12, 1#12 GND - 3/4"C

GENERAL EQUIPMENT SCHEDULE NOTES: REFERENCED NOTES:

A. MOUNT ALL DISCONNECTS AND STARTERS ON UNIT UNLESS INDICATED OTHERWISE. 1.

MOUNT ALL WITH CLEARANCES AS PER NEC. COORDINATE WITH MECHANICAL.

B. SFT = FUSIBLE SWITCH UNIT (BUSS #SSU OR APPROVED EQUAL) WITH FUSE.

C. FVNR = FULL VOLTAGE NON-REVERSING MOTOR STARTER.

D. CS/NFD, FD = COMBINATION STARTER / NON OR FUSED DISCONNECT SWITCH.

E. NFD OR FD = NON OR FUSED DISCONNECT SWITCH.

F. ALL SWITCHES, DISCONNECTS, ETC SHALL BE LOCKABLE IN ON AND OFF POSITION.

G. ALL SWITCHES, DISCONNECTS, ETC SHALL BE NEMA 3R WHERE REQUIRED.

H. PROVIDE FUSES AS SHOWN, REVISE SIZES PER ACTUAL NAMEPLATE DATA.

I. STARTER ACCESSORIES:

1) CONTROL TRANSFORMER

2) H-O-A SWITCH

3) RED RUN LIGHT

4) 2 NC CONTACT; 2 NO CONTACTS

ENCLOSURE SHALL BE RATED FOR CLASS II, DIV 1 LOCATION,

SUITABLE FOR DUST/IGNITION PROOF APPLICATION.

DISCONNECT PLUG

CONFIG

RECPT

CONFIG

FEEDER

SIZE NOTES

ELECTRICAL EQUIPMENT SCHEDULE

DEVICE DESCRIPTION VOLTAGE PH KVA FLA HP

STARTER

PRIMARY

FEEDER SIZE

TRP 408V DELTA, 3W 208Y/120V, 3PH-4W 30 3#6, 1#10 GND - 1"C 1

TPP 408V DELTA, 3W 208Y/120V, 3PH-4W 30 3#6, 1#10 GND - 1"C

THP1 408V DELTA, 3W 208Y/120V, 3PH-4W 75 3#1, 1#6 GND - 1 1/4"C

NOTES:

1 PROVIDE WALL MOUNT FOR TRANSFORMER. SECURE TO

STRUCTURE ABOVE SUCH THAT BOTTOM OF TRANSFORMER IS

AT 7'-6" AFF. PROVIDE ALL HARDWARE, PARTS, AND ACCESSORIES AS REQUIRED.

TRANSFORMER SCHEDULE

DESIGNATION PRIMARY VOLTAGE SECONDARY VOLTAGE KVA REMARKS

CKT CIRCUIT NAMEPLATE NO & SIZE BRANCHES OC DEVICE ACTUAL

PANEL DESIGNATION NO DESIGNATION FRAME WIRE SPARE SPACE TYPE TRIP REMARKS LOAD

POWER PANEL MDP 1 PANEL 'LP' 125 4 CB 90 SEE PANEL SCHEDULE FOR FEEDER SIZE 72

277/ 480 VOLTS, 3 PH, 4 W. 2 TRANSFORMER 'TRP' 125 3 CB 45 SEE TRANSFORMER SCHED FOR PRIMARY FEEDER SIZE 32

400 AMP BUS 3 TRANSFORMER 'TPP' 125 3 CB 45 SEE TRANSFORMER SCHED FOR PRIMARY FEEDER SIZE 27

400 MAIN BREAKER 4 TRANSFORMER 'THP1' 125 3 CB 110 SEE TRANSFORMER SCHED FOR PRIMARY FEEDER SIZE 73

42,000 AIC CURRENT 5 PANEL 'HP2' 250 4 CB 175 SEE PANEL SCHEDULE FOR FEEDER SIZE 139

SERVICE RATED YES 6 SPARE 125

FEEDER ENTRANCE BOTTOM 7 SPACE 125

ENCLOSURE TYPE 1 8 SPARE 125

9 SPACE 125

POWER PANEL FEEDER

(2) 4#3/0 - 2"C

NOTE: 1. ALL FUSES/BREAKERS ARE 3 POLE UNLESS NOTED OTHERWISE. FLA 344

EMD 241

MINIMUM OCP 301

POWER PANEL SCHEDULE

PANELBOARD NO: RP

VOLTAGE: 208Y/120 BUS RATING: 125A ENCLOSURE: NEMA 1

PHASE: 3 MAIN OC DEVICE: 100/3 CB MOUNTING: SURFACE

WIRE: 4+GND INTERRUPTING RATING: 10 KA LOCATION: ELECT ROOM

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 4#1, 1#6 GND - 1 1/2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 REC NORTH TOOL STORAGE 600 20 1 A 20 1 600 REC COVERED LOADING APRON 2

3 REC EAST SOUTH TOOL ROOM 600 20 1 B 20 1 800 REC WEST ACCESS AISLE 4

5 REC WEST SOUTH TOOL STORAGE 600 20 1 C 20 1 800 REC EAST ACCESS AISLE 6

7 REC MECHANICAL 800 20 1 A 20 1 800 REC NORTH INSP BAYS 8

9 REC ELECTRICAL RESTROOM 1,000 20 1 B 20 1 600 REC EAST INSP BAY 10

11 EWC 400 20 1 C 20 1 600 REC EAST INSP BAY 12

13 EWC 400 20 1 A 20 1 600 REC NORTH BAY SUPPORT 14

15 REC CORRIDOR 1,000 20 1 B 20 1 800 REC SOUTH EAST BAY SUPPORT 16

17 FIRE ALARM CONTROL PANEL (NOTE 1) 1,200 20 1 C 20 1 600 REC WEST BAY SUPPORT 18

19 MASS NOTIFICATION CONTROL PANEL 1,200 20 1 A 20 1 600 REC NORTH EAST SUPPLY ROOM 20

21 MASS NOTIFICATION AMP/POWER SUPPLY 1,200 20 1 B 20 1 600 REC EAST SOUTH SUPPLY ROOM 22

23 INTRUSION DETECTION SYSTEM 1,000 20 1 C 20 1 600 REC WEST SUPPLY JAN CLOSET 24

25 FIRE ALARM NACP 1,000 20 1 A 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 26

27 DOOR LOCK POWER SUPPLIES 1,000 20 1 B 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 28

29 DOOR LOCK POWER SUPPLIES 1,000 20 1 C 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 30

31 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A SPACE (LEAVE BLANK) 32

33 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B SPACE (LEAVE BLANK) 34

35 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 C SPACE (LEAVE BLANK) 36

37 SPACE (LEAVE BLANK) A 30 3 TVSS 38

39 SPACE (LEAVE BLANK) B 40

41 SPACE (LEAVE BLANK) C 42

LTS REC MECH MISC

0.0 10.8 2.6 7.6 208 LINE-TO-LINE VOLTS PHASE A (KVA) 7

1.00 NEC 0.80 1.00 58 CONNECTED AMPS PHASE B (KVA) 8

0.0 10.4 2.1 7.6 75 DESIGN AMPS PHASE C (KVA) 7

93.3586

PANEL NOTES:

1. PROVIDE LABEL FOR CIRCUIT INDICATING "FIRE ALARM CONTROL PANEL" . PROVIDE MEANS FOR LOCKING BREAKER IN "ON" POSITION.

SPARE TOTAL

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

21.0

26.9

PHASE BALANCE

CONNECTED LOAD (KVA)

DEMAND FACTOR

DESIGN LOAD (KVA)

34%

6.8

PANELBOARD NO: LP

VOLTAGE: 480Y/277 BUS RATING: 125A ENCLOSURE: NEMA 1

PHASE: 3 MAIN OC DEVICE: MLO MOUNTING: SURFACE

WIRE: 4+GND INTERRUPTING RATING: 22 KA LOCATION: ELECT ROOM

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 4#2, 1#8 GND - 1 1/4"

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 LTG MECH,ELEC,CORR,JAN,SUPPLY 1,800 20 1 A 20 2 1,500 LTG AMMO HOLDING PRKING 2

3 LTG TOOL STOR, BAY SUPPORT 1,600 20 1 B 1,500 4

5 LTG INSP BAY 1,700 20 1 C 20 1 1,000 LIGHTING CONTROL PANEL 6

7 LTG INSP BAY 2,000 20 1 A 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 8

9 LTG STORAGE CUBICALS 700 20 1 B 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 10

11 LTG EAST WEST ACCESS AISLE 1,800 20 1 C 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 12

13 LTG NORTH ACCESS AISLE LOADING APRON 1,400 20 1 A 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 14

15 LTG EXTERIOR 1,300 20 1 B 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 16

17 EMERG LTG ACCESS AISLES, INSP BAY 200 20 1 C 20 1 SPARE (LEAVE BLANK; CB OFF POSITION) 18

19 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 20

21 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 22

23 SPACE (LEAVE BLANK) C SPACE (LEAVE BLANK) 24

25 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 26

27 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 28

29 SPACE (LEAVE BLANK) C SPACE (LEAVE BLANK) 30

LTS REC MECH MISC

16.5 0.0 0.0 0.0 208 LINE-TO-LINE VOLTS PHASE A (KVA) 7

1.00 NEC 0.80 1.00 46 CONNECTED AMPS PHASE B (KVA) 5

16.5 0.0 0.0 0.0 72 DESIGN AMPS PHASE C (KVA) 5

16.5

25.9

PHASE BALANCE

CONNECTED LOAD (KVA)

DEMAND FACTOR

DESIGN LOAD (KVA)

57%

9.4

SPARE TOTAL

PANELBOARD NO: PP

VOLTAGE: 208Y/120 BUS RATING: 125A ENCLOSURE: NEMA 1

PHASE: 3 MAIN OC DEVICE: 100/3 CB MOUNTING: SURFACE

WIRE: 4+GND INTERRUPTING RATING: 10 KA LOCATION: ELECT ROOM

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 4#1, 1#6 GND - 1 1/2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 SF-1 50 20 1 A 20 1 50 UH-1 2

3 EF-1 405 20 1 B 20 1 300 UH-2 4

5 B-1 500 20 1 C 20 1 300 UH-3 6

7 OVERHEAD DOOR 1,500 20 1 A 20 1 300 UH-4 8

9 OVERHEAD DOOR 1,500 20 1 B 20 1 300 UH-5 10

11 DWH-1 1,500 20 1 C 20 1 300 UH-6 12

13 ACCU-1 2,800 40 3 A 20 1 300 UH-7 14

15 2,800 B 20 1 300 UH-8 16

17 2,800 C 20 1 300 UH-9 18

19 AD-1 1,000 20 1 A 20 1 300 UH-10 20

21 SPARE (LEAVE BLANK; CB OFF POSITION) B 20 1 300 UH-11 22

23 SPARE (LEAVE BLANK; CB OFF POSITION) C 20 1 300 UH-12 24

25 SPARE (LEAVE BLANK; CB OFF POSITION) A 20 1 300 UH-13 26

27 SPARE (LEAVE BLANK; CB OFF POSITION) B SPARE (LEAVE BLANK; CB OFF POSITION) 28

29 SPARE (LEAVE BLANK; CB OFF POSITION) C SPARE (LEAVE BLANK; CB OFF POSITION) 30

31 SPACE (LEAVE BLANK A SPACE (LEAVE BLANK) 32

33 SPACE (LEAVE BLANK B SPACE (LEAVE BLANK) 34

35 SPACE (LEAVE BLANK C SPACE (LEAVE BLANK) 36

37 SPACE (LEAVE BLANK A SPACE (LEAVE BLANK) 38

39 SPACE (LEAVE BLANK B SPACE (LEAVE BLANK) 40

41 SPACE (LEAVE BLANK C SPACE (LEAVE BLANK) 42

LTS REC MECH MISC

0.0 0.0 15.5 3.0 208 LINE-TO-LINE VOLTS PHASE A (KVA) 7

1.00 NEC 0.80 1.00 51 CONNECTED AMPS PHASE B (KVA) 6

0.0 0.0 12.4 3.0 63 DESIGN AMPS PHASE C (KVA) 6

CONNECTED LOAD (KVA)

DEMAND FACTOR

DESIGN LOAD (KVA)

47%

7.2

18.5

22.6

PHASE BALANCESPARE TOTAL

PANELBOARD NO: HP1

VOLTAGE: 208Y/120 BUS RATING: 400A ENCLOSURE: NEMA 1

PHASE: 3 MAIN OC DEVICE: 250/3 CB MOUNTING: SURFACE

WIRE: 4+GND INTERRUPTING RATING: 10 KA LOCATION: ELECT ROOM

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 4#250MCM, 1#2 GND - 2 1/2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 208 V RECEPTACLE 3,000 30 3 A 30 3 3,000 208 V RECEPTACLE 2

3 EAST ACCESS AISLE 3,000 B 3,000 WEST ACCESS AISLE 4

5 NORTH 3,000 C 3,000 NORTH 6

7 208 V RECEPTACLE 3,000 30 3 A 30 3 3,000 208 V RECEPTACLE 8

9 EAST ACCESS AISLE 3,000 B 3,000 WEST ACCESS AISLE 10

11 CENTER 3,000 C 3,000 CENTER 12

13 208 V RECEPTACLE 3,000 30 3 A 30 3 3,000 208 V RECEPTACLE 14

15 EAST ACCESS AISLE 3,000 B 3,000 WEST ACCESS AISLE 16

17 SOUTH 3,000 C 3,000 SOUTH 18

19 208 V RECEPTACLE 3,000 30 3 A 30 3 3,000 208 V RECEPTACLE 20

21 INSPECTION BAY 215 3,000 B 3,000 INSPECTION BAY 210 22

23 3,000 C 3,000 24

25 208 V RECEPTACLE 3,000 30 3 A 30 3 3,000 208 V RECEPTACLE 26

27 INSPECTION BAY 213 3,000 B 3,000 INSPECTION BAY 210 28

29 3,000 C 3,000 30

31 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 32

33 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 34

35 SPACE (LEAVE BLANK) C SPACE (LEAVE BLANK) 36

37 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 38

39 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 40

41 SPACE (LEAVE BLANK) C SPACE (LEAVE BLANK) 42

LTS REC MECH MISC

0.0 90.0 0.0 0.0 208 LINE-TO-LINE VOLTS PHASE A (KVA) 30

1.00 NEC 0.80 1.00 250 CONNECTED AMPS PHASE B (KVA) 30

0.0 50.0 0.0 0.0 169 DESIGN AMPS PHASE C (KVA) 30

SPARE TOTAL

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

90.0

61.0

PHASE BALANCE

CONNECTED LOAD (KVA)

DEMAND FACTOR

DESIGN LOAD (KVA)

22%

11.0

PANELBOARD NO: HP2

VOLTAGE: 480Y/277 BUS RATING: 225A ENCLOSURE: NEMA 1

PHASE: 3 MAIN OC DEVICE: MLO MOUNTING: SURFACE

WIRE: 4+GND INTERRUPTING RATING: 22 KA LOCATION: ELECT ROOM

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 4#2/0, 1#6 GND - 2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 EF-2 450 20 3 A 15 3 750 HWP-1 2

3 450 B 750 4

5 450 C 750 6

7 EF-3 450 20 3 A 15 3 750 HWP-2 8

9 450 B 750 10

11 450 C 750 12

13 EF-4 450 20 3 A 80 3 11,100 AC-1 14

15 450 B 11,100 16

17 450 C 11,100 18

19 EF-5 450 20 3 A 20 3 830 BC-1 20

21 450 B 830 22

23 450 C 830 24

25 EF-6 450 20 3 A 30 3 500 BLAST DOOR 26

27 450 B 500 TEST CUBICLE 28

29 450 C 500 NORTH 30

31 SPACE (LEAVE BLANK) A 30 3 500 BLAST DOOR 32

33 SPACE (LEAVE BLANK) B 500 TEST CUBICLE 34

35 SPACE (LEAVE BLANK) C 500 SOUTH 36

37 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 38

39 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 40

41 SPACE (LEAVE BLANK) C SPACE (LEAVE BLANK) 42

LTS REC MECH MISC

0.0 0.0 50.0 0.0 208 LINE-TO-LINE VOLTS PHASE A (KVA) 17

1.00 NEC 0.80 1.00 139 CONNECTED AMPS PHASE B (KVA) 17

0.0 0.0 40.0 0.0 139 DESIGN AMPS PHASE C (KVA) 17

CONNECTED LOAD (KVA)

DEMAND FACTOR

DESIGN LOAD (KVA)

25%

10.0

50.0

50.0

PHASE BALANCESPARE TOTAL

MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE

MARK FUNCTION SERVES LOCATION OPERATING CONDITIONS CAPACITY AND MOTOR HP. REMARKS

LV-1 INTAKE INERT INERT 2000 CFM 42" x 30" 1 2

STORAGE STORAGE 0.1" WC MAX PRESSURE DROP 437 FPM

301 301

REMARKS

1. PROVIDE WITH MOTORIZED BACKDRAFT DAMPER AND BIRDSCREEN.

2. PRIME COAT FOR FIELD FINISH.

MARK LOCATION SERVES REMARKS

TYPE CFM EXT. SP. DIA. DRIVE RPM RPM HP VOLT PH HZ

IN. WG. IN.

EF-1 INERT STORAGE INERT STORAGE PROPELLER WALL FAN 2000 0.125 20 DIRECT 1115 1725 0.167 120 1 60 1 2 3 4

REMARKS

1. PROVIDE FAN WITH GRAVITY BACKDRAFT DAMPERS.

2. ALL COMPONENTS OF FAN, DAMPER, ETC, EXPOSED TO AIR STREAM SHALL BE CONSTRUCTED OF ALUMINUM.

3. SUSPEND FAN FROM STRUCTURE ABOVE WITH SPRING VIBRATION ISOLATORS.

4. ALL AIR FLOW ARE SCHEDULED FOR OPERATION AT 4785.0 FEET ABOVE SEA LEVEL.

ELECTRICAL DATA

FAN SCHEDULE

FAN DATA

EF-1 EXHAUST FAN 120 1 - - 1/6 - - SFT 15/1 6.25 - - 2#12, 1#12 GND - 3/4"C

EUH-1,2,3,4,5,6 ELECTRIC UNIT HEATER 240 1 - 12.5 - - - FD 30/2 20 - - 2#12, 1#12 GND - 3/4"C 1 2

GENERAL EQUIPMENT SCHEDULE NOTES: REFERENCED NOTES:

A. MOUNT ALL DISCONNECTS AND STARTERS ON UNIT UNLESS INDICATED OTHERWISE. 1. UNIT HAS INTEGRAL CONTROLS. COORDINATE REQUIREMENTS PRIOR

MOUNT ALL WITH CLEARANCES AS PER NEC. COORDINATE WITH MECHANICAL. TO ORDERING.

B. SFT = FUSIBLE SWITCH UNIT (BUSS #SSU OR APPROVED EQUAL) WITH FUSE. 2. PROVIDE QMARK #MUH03-21 (OR EQUAL) FORCED AIR HEATER.

C. NFD OR FD = NON OR FUSED DISCONNECT SWITCH. PROVIDE WALL MOUNTING BRACKET.

D. ALL SWITCHES, DISCONNECTS, ETC SHALL BE LOCKABLE IN ON AND OFF POSITION.

E. ALL SWITCHES, DISCONNECTS, ETC SHALL BE NEMA 3R WHERE REQUIRED.

F. PROVIDE FUSES AS SHOWN, REVISE SIZES PER ACTUAL NAMEPLATE DATA.

DISCONNECT PLUG

CONFIG

RECPT

CONFIG

FEEDER

SIZE NOTES

ELECTRICAL EQUIPMENT SCHEDULE

DEVICE DESCRIPTION VOLTAGE PH KVA FLA HP

STARTER

TYPE QTY WATTS VOLTS VA TYPE HEIGHT

E1

AC POWERED RED LED EXIT SIGN W/ BATTERY

HOUSING: POLYCARBONATE/WHITE

FACES: NUMBER AND CHEVERONS AS INDICATED

BATTERY: SEALED LEAD CALCIUM

SURE-LITES

SLX70RWH

LED 120 4 SURFACE CEILING

T2

4' FLUORESCENT INDUSTRIAL TURRET

EXPLOSION PROOF

HOUSING: HEAVY DUTY STEAL, BAKED ENAMEL TURRET

METALUX

DIM / 232 / UNV / ER81

F32T8/

3 32

PROGRAM

START

ELECTRONIC

120 89 SURFACE CEILING

T2A

4' FLUORESCENT INDUSTRIAL TURRET W/ BATTERY

HOUSING: HEAVY DUTY STEEL, BAKED ENAMEL

BATTERY: SEALED LEAD CALCIUM

METALUX

DIM / 232 / EM / ER81

F32T8/

3 32

PROGRAM

START

ELECTRONIC

120 89 SURFACE CEILING

W1

ARCH AREA LT W/ EMERGENCY MR16 SOCKET

LENS: CLEAR TEMPERED GLASS

REFLECTOR: SPECULAR ALZAK

HOUSING: BRONZE PAINTED DIECAST ALUMINUM

LUMARK

HPIP / S / 50 / MT / EM-SC-12V

MED BASE

HPS50

1 70

MULTI-VOLT

MAGNETIC

120 91 WALL +9'-0" AFG 1, 2

NOTES:

1. MOUNTING HEIGHT TO BE MEASURED FROM BOTTOM OF FIXTURE.

2. PROVIDE FIXTURE WITH 12V, 35W BI-PIN MR-16 LAMP. PROVIDE 12V EMERGENCY BATTERY PACK AND CONNECT TO MR-16.

3. MANUFACTURER AND MODEL NOS. LISTED ARE INTEDED ONLY AS A REFERENCE TO REQUIRED PERFORMANCE AND

SALIENT CHARACTERISTICS. OTHER MANUFACTURERS SHALL BE ALLOWED AS APPROVED EQUAL.

LUMINAIRE SCHEDULE

MANUFACTURER AND

LUMINAIRE TYPE

DESCRIPTION

DWG

ID

TYPE

NOTESBALLAST

FIXTURE MOUNTING

W SERIES - WALL MOUNT

T SERIES - INDUSTRIAL TURRET

LAMP

E SERIES - EMERGENCY LIGHTING

FURNISHED W/

LUMINAIRE

PANELBOARD NO: IP1

VOLTAGE: 120/240 BUS RATING: 125A ENCLOSURE: NEMA 1

PHASE: 1 MAIN OC DEVICE: 125/2 CB MOUNTING: SURFACE

WIRE: 3 INTERRUPTING RATING: 10 KA LOCATION: INERT STORAGE 301

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: YES FEEDER: 3#1 - 1 1/4"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 INERT STORAGE LTS WEST 800 20 1 A 20 1 800 WEST/SOUTH RECEPTACLES 2

3 INERT STORAGE LTS EAST 800 20 1 B 20 1 800 NORTH/EAST RECEPTACLES 4

5 EXTERIOR LTS 300 20 1 A 20 2 1,500 EUH-1 6

7 OVERHEAD DOOR 1,100 20 1 B 1,500 8

9 MASS NOTIFICATION PANEL 1,000 20 1 A 20 2 1,500 EUH-2 10

11 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 1,500 12

13 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 20 2 1,500 EUH-3 14

15 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 1,500 16

17 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 20 2 1,500 EUH-4 18

19 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 1,500 20

21 SPACE (LEAVE BLANK) A 20 2 1,500 EUH-5 22

23 SPACE (LEAVE BLANK) B 1,500 24

25 SPACE (LEAVE BLANK) A 20 2 1,500 EUH-6 26

27 SPACE (LEAVE BLANK) B 1,500 28

29 SPACE (LEAVE BLANK) A 20 1 405 EF-1 30

LTS REC MECH MISC

CONNECTED LOAD (KVA) 1.9 1.6 18.4 2.1 240 LINE-TO-LINE VOLTS PHASE A (KVA) 12

DEMAND FACTOR 1.00 NEC 0.80 1.00 100 CONNECTED AMPS PHASE B (KVA) 12

DESIGN LOAD (KVA) 1.9 1.6 14.7 2.1 100 DESIGN AMPS

PHASE BALANCE

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

24.0

24.0

TOTAL

SPARE

18%

3.7

V H V H V (MAX/MIN) H (MAX/MIN) V (MAX/MIN) H (MAX/MIN)

A1, A4, C1, C4 9.6 4.0 12.0 4.4 -8.9, 2.7 -4.7, 3.6 - 1.5

A2, A3, C2, C3 9.6 4.0 12.0 4.4 -8.9, 2.7 -4.7, 3.6 -6.9, 6.9 -9.7, 9.7

B1, B4 3.8 - 3.8 - - - - 2.4

NOTES:

1. SEE PRE-ENGINEERED BUILDING NOTES, SHEET 00S001

2. DEAD LOAD REACTIONS INCLUDE A COLLATERAL LOAD OF 9 PSF OF COLLATERAL LOAD.

3. REACTIONS SHOWN ARE FROM SERVICE LOADS.

4. LATERAL LOADS SHOWN AS NEGATIVE ACT EITHER UPWARD OR INWARD TOWARDS THE BUILDING.

LATERAL LOAD

COLUMN BASE REACTIONS

DEAD LOAD LIVE LOAD NORTH/SOUTH EAST/WEST

COLUMN MARK

EF-1 EXHAUST FAN 120 1 - - 1/6 - - SFT 15/1 6.25 - - 2#12, 1#12 GND - 3/4"C 3

EUH-1,2,3,4,5,6 ELECTRIC UNIT HEATER 240 1 - 33.6 - - - FD 60/2 45 - - 2#6, 1#10 GND - 1"C 1 2 3

GENERAL EQUIPMENT SCHEDULE NOTES: REFERENCED NOTES:

A. MOUNT ALL DISCONNECTS AND STARTERS ON UNIT UNLESS INDICATED OTHERWISE. 1. UNIT HAS INTEGRAL CONTROLS. COORDINATE REQUIREMENTS PRIOR

MOUNT ALL WITH CLEARANCES AS PER NEC. COORDINATE WITH MECHANICAL. TO ORDERING.

B. SFT = FUSIBLE SWITCH UNIT (BUSS #SSU OR APPROVED EQUAL) WITH FUSE. 2. PROVIDE QMARK #GUX500412 (OR EQUAL) FORCED AIR HEATER.

C. NFD OR FD = NON OR FUSED DISCONNECT SWITCH. PROVIDE WALL MOUNTING BRACKET.

D. ALL SWITCHES, DISCONNECTS, ETC SHALL BE LOCKABLE IN ON AND OFF POSITION. 3.

E. ALL SWITCHES, DISCONNECTS, ETC SHALL BE NEMA 3R WHERE REQUIRED.

F. PROVIDE FUSES AS SHOWN, REVISE SIZES PER ACTUAL NAMEPLATE DATA.

ELECTRICAL EQUIPMENT SCHEDULE

DEVICE DESCRIPTION VOLTAGE PH KVA FLA HP

STARTER

ENCLOSURE SHALL BE RATED FOR CLASS II, DIV 1 LOCATION,

SUITABLEFOR DUST/IGNITION PROOF APPLICATION.

DISCONNECT PLUG

CONFIG

RECPT

CONFIG

FEEDER

SIZE NOTES

TYPE QTY WATTS VOLTS VA TYPE HEIGHT

E1

AC POWERED RED LED EXIT SIGN W/ BATTERY

(HAZ LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

FACES: NUMBER AND CHEVERONS AS INDICATED

BATTERY: SEALED LEAD CALCIUM

RIG-A-LITE

XPEX / 1 / R / UC / DT / WP / EM

LED 120 4

SURFACE,

WALL

+9'-0"

T1

4' FLUORESCENT (HAZ. LOCATION - CLASS II, DIV 1)

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

RIG-A-LITE

XP265 / 4 / 3L / C

F32T8/

3 32

PROGRAM

START

ELECTRONIC

120 89 SURFACE CEILING

T1B

4' FLUORESCENT (HAZ. LOCATION - CLASS II, DIV 1)

W/ BATTERY

DUST/IGNITION PROOF

HOUSING: NEMA 4 ALUMINUM

BATTERY: SEALED LEAD CALCIUM

RIG-A-LITE

XP265 / 4 / 3L / C / EM

F32T8/

3 32

PROGRAM

START

ELECTRONIC

120 89 SURFACE CEILING

W1

ARCH AREA LT W/ EMERGENCY MR16 SOCKET

LENS: CLEAR TEMPERED GLASS

REFLECTOR: SPECULAR ALZAK

HOUSING: BRONZE PAINTED DIECAST ALUMINUM

LUMARK

HPIP / S / 50 / MT / EM-SC-12V

MED BASE

HPS50

1 70

MULTI-VOLT

MAGNETIC

120 91 WALL +9'-0" AFG 1, 2

NOTES:

1. MOUNTING HEIGHT TO BE MEASURED FROM BOTTOM OF FIXTURE.

2. PROVIDE FIXTURE WITH 12V, 35W BI-PIN MR-16 LAMP. PROVIDE 12V EMERGENCY BATTERY PACK AND CONNECT TO MR-16.

3. MANUFACTURER AND MODEL NOS. LISTED ARE INTEDED ONLY AS A REFERENCE TO REQUIRED PERFORMANCE AND

SALIENT CHARACTERISTICS. OTHER MANUFACTURERS SHALL BE ALLOWED AS APPROVED EQUAL.

BALLAST

FIXTURE MOUNTING

W SERIES - WALL MOUNT

T SERIES - INDUSTRIAL TURRET

LAMP

E SERIES - EMERGENCY LIGHTING

FURNISHED W/

LUMINAIRE

LUMINAIRE SCHEDULE

MANUFACTURER AND

LUMINAIRE TYPE

DESCRIPTION

DWG

ID

TYPE

NOTES

PANELBOARD NO: BP1

VOLTAGE: 120/240 BUS RATING: 400A ENCLOSURE: CLASS II, DIV 1 DUST/IGNITION PROOF

PHASE: 1 MAIN OC DEVICE: 250/2 CB MOUNTING: SURFACE

WIRE: 3 INTERRUPTING RATING: 10 KA LOCATION: BREAKDOWN ROOM 401

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: YES FEEDER: 3#250MCM - 2"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 WEST LIGHTS 900 20 1 A 20 1 600 WEST/NORTH RECEPTACLES 2

3 EAST LIGHTS 900 20 1 B 20 1 600 SOUTH/EAST RECEPTACLES 4

5 EXTERIOR LIGHTS 300 20 1 A 20 1 405 EF-1 6

7 OVERHEAD DOOR 1,200 20 1 B 50 2 4,100 EUH-1 8

9 MASS NOTIFICATION SYSTEM 1,000 20 1 A 4,100 10

11 OVERHEAD DOOR 1,200 20 1 B 50 2 4,100 EUH-2 12

13 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 4,100 14

15 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 50 2 4,100 EUH-3 16

17 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 4,100 18

19 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 B 50 2 4,100 EUH-4 20

21 SPARE (LEAVE BLANK; CB OFF POSITION) 20 1 A 4,100 22

23 SPACE (LEAVE BLANK) B 50 2 4,100 EUH-5 24

25 SPACE (LEAVE BLANK) A 4,100 26

27 SPACE (LEAVE BLANK) B 50 2 4,100 EUH-6 28

29 SPACE (LEAVE BLANK) A 4,100 30

LTS REC MECH MISC

CONNECTED LOAD (KVA) 2.1 1.2 49.6 3.4 240 LINE-TO-LINE VOLTS PHASE A (KVA) 28

DEMAND FACTOR 1.00 NEC 0.80 0.50 235 CONNECTED AMPS PHASE B (KVA) 29

DESIGN LOAD (KVA) 2.1 1.2 39.7 1.7 195 DESIGN AMPS

56.3

46.9

TOTAL

SPARE

5%

2.2

PHASE BALANCE

PANELBOARD NO: E2

VOLTAGE: 120/240 BUS RATING: 125A ENCLOSURE: NEMA 3R

PHASE: 1 MAIN OC DEVICE: 80/2 CB MOUNTING: SURFACE

WIRE: 3+GND INTERRUPTING RATING: 10 KA LOCATION: BUILDING EXTERIOR

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: NO FEEDER: 3#3, 1#8 GND - 1"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 EXTERIOR LIGHTS EMC-6,7,8,9,10,11 1,500 20 1 A 20 2 750 EXTERIOR ROADWAY LIGHTING 2

3 LIGHTING RECEPTACLE EMC-6 600 200 20 1 B 750 4

5 LIGHTING RECEPTACLE EMC-7 600 200 20 1 A 20 1 500 CAMERA POWER EMC NORTH 6

7 LIGHTING RECEPTACLE EMC-8 600 200 20 1 B 20 1 500 CAMERA POWER EMC MID 8

9 LIGHTING RECEPTACLE EMC-9 600 200 20 1 A 20 1 500 CAMERA POWER EMC MID 10

11 LIGHTING RECEPTACLE EMC-10 600 200 20 1 B 20 1 500 CAMERA POWER EMC SOUTH 12

13 LIGHTING RECEPTACLE EMC-11 600 200 20 1 A SPACE (LEAVE BLANK) 14

15 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 16

17 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 18

LTS REC MECH MISC

CONNECTED LOAD (KVA) 6.6 3.2 0.0 0.0 240 LINE-TO-LINE VOLTS PHASE A (KVA) 6

DEMAND FACTOR 1.00 NEC 0.80 1.00 41 CONNECTED AMPS PHASE B (KVA) 4

DESIGN LOAD (KVA) 6.6 3.2 0.0 0.0 60 DESIGN AMPS

SPARE

48%

4.7

9.8

14.5

TOTAL PHASE BALANCE

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

PANELBOARD NO: E1

VOLTAGE: 120/240 BUS RATING: 225A ENCLOSURE: NEMA 3R

PHASE: 1 MAIN OC DEVICE: 150/2 CB MOUNTING: SURFACE

WIRE: 3 INTERRUPTING RATING: 10 KA LOCATION: BUILDING EXTERIOR

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: YES FEEDER: 3#1/0 - 1 1/4"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 EXTERIOR LIGHTS EMC-1,2,3,4,5 1,250 20 1 A 20 2 600 EXTERIOR ROADWAY LIGHTING 2

3 LIGHTING REC EMC-1 600 200 20 1 B 600 4

5 LIGHTING REC EMC-2 600 200 20 1 A 20 1 500 CAMERA POWER NORTH 6

7 LIGHTING REC EMC-3 600 200 20 1 B 20 1 500 CAMERA POWER MID 8

9 LIGHTING REC EMC-4 600 200 20 1 A 20 1 500 CAMERA POWER SOUTH 10

11 LIGHTING REC EMC-5 600 200 20 1 B SPACE (LEAVE BLANK) 12

13 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 14

15 SPACE (LEAVE BLANK) B 80 2 8,362 PANEL E2 16

17 SPACE (LEAVE BLANK) A 6,142 18

LTS REC MECH MISC

CONNECTED LOAD (KVA) 5.5 2.5 0.0 14.5 240 LINE-TO-LINE VOLTS PHASE A (KVA) 11

DEMAND FACTOR 1.00 NEC 0.80 1.00 94 CONNECTED AMPS PHASE B (KVA) 12

DESIGN LOAD (KVA) 5.5 2.5 0.0 14.5 112 DESIGN AMPS

PHASE BALANCE

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

22.5

26.9

TOTAL

SPARE

20%

4.5

PANELBOARD NO: DP1

VOLTAGE: 120/240 BUS RATING: 125A ENCLOSURE: NEMA 4

PHASE: 1 MAIN OC DEVICE: 125/2 CB MOUNTING: SURFACE

WIRE: 3 INTERRUPTING RATING: 10 KA LOCATION: RECEIVING 601

200% NEUTRAL: NO SERVICE ENTRANCE LABEL: YES FEEDER: 3#1 - 1 1/4"C

CKT CKT

NO. DESCRIPTION LTS REC MECH MISC AMPS P AMPS P LTS REC MECH MISC DESCRIPTION NO.

1 RECEIVING LIGHTS 1,200 20 1 A 20 1 400 RECEIVING RECEPTACLES 2

3 1,200 B 40 2 2,040 DOCK LEVELER 4

5 EXTERIOR LIGHTS 600 20 1 A 2,040 6

7 MASS NOT. HPSA 400 20 2 B 40 2 2,040 DOCK LEVELER 8

9 400 A 2,040 10

11 SPARE (LEAVE BLANK; CB OFF POSITION) B 40 2 2,040 DOCK LEVELER 12

13 SPARE (LEAVE BLANK; CB OFF POSITION) A 2,040 14

15 SPACE (LEAVE BLANK) B SPACE (LEAVE BLANK) 16

17 SPACE (LEAVE BLANK) A SPACE (LEAVE BLANK) 18

LTS REC MECH MISC

CONNECTED LOAD (KVA) 3.8 0.4 0.0 12.2 240 LINE-TO-LINE VOLTS PHASE A (KVA) 9

DEMAND FACTOR 1.00 NEC 0.80 0.80 69 CONNECTED AMPS PHASE B (KVA) 8

DESIGN LOAD (KVA) 3.8 0.4 0.0 9.8 99 DESIGN AMPS

PHASE BALANCE

LOAD SUMMARY

CONNECTED LOAD (VA) OCP OCP CONNECTED LOAD (VA)

16.4

23.8

TOTAL

SPARE

70%

9.8

TYPE QTY WATTS VOLTS VA TYPE HEIGHT

P1

HID AREA LIGHT

HOUSING: DIE CAST ALUMINUM

LENS: POLYCARBONATE

LUMARK

HPPR / 175 / HPF / 240V

HPS 1 175

MULTITAP

ELECTRONIC

240 195 CEILING CEILING

W1

ARCH AREA LT W/ EMERGENCY MR16 SOCKET

LENS: CLEAR TEMPERED GLASS

REFLECTOR: SPECULAR ALZAK

HOUSING: BRONZE PAINTED DIECAST ALUMINUM

LUMARK

HPIP / S / 50 / MT / EM-SC-12V

MED BASE

HPS50

1 70

MULTI-VOLT

MAGNETIC

120 91 WALL +9'-0" AFG 1, 2

NOTES:

1. MOUNTING HEIGHT TO BE MEASURED FROM BOTTOM OF FIXTURE.

2. PROVIDE FIXTURE WITH 12V, 35W BI-PIN MR-16 LAMP. PROVIDE 12V EMERGENCY BATTERY PACK AND CONNECT TO MR-16.

3. MANUFACTURER AND MODEL NOS. LISTED ARE INTEDED ONLY AS A REFERENCE TO REQUIRED PERFORMANCE AND

SALIENT CHARACTERISTICS. OTHER MANUFACTURERS SHALL BE ALLOWED AS APPROVED EQUAL.

MOUNTING

W SERIES - WALL MOUNT

P SERIES - INDUSTRIAL TURRET

LAMP

LUMINAIRE SCHEDULE

MANUFACTURER AND

LUMINAIRE TYPE

DESCRIPTION

DWG

ID

TYPE

NOTESBALLAST

FIXTURE