ASP 08315 Sliding Blast Resistant Door Addendum 0009.doc

DOC document 41 KB Posted

Attached to
Construction of an Ammunitions Supply Point Facility Federal contract opportunity
Solicitation number
W911YP-09-B-0002
Issued by
Department of the Army Utah Army National Guard

About this file

Section 08315 - Sliding Blast Resistant Door

View the file

Other files for this federal contract opportunity

Other files attached to Construction of an Ammunitions Supply Point Facility, newest first.
File Type Posted
ASP Addendum 0010.doc DOC document
ASP Davis Bacon UT080039.pdf PDF
ASP Davis Bacon UT080060.pdf PDF
ASP RFIs Addendum 0009.doc DOC document
ASP 01360 —
ASP Addendum 0009 Utah National Guard Seed Mix.doc DOC document
ASP Addendum 0009.doc DOC document
ASP Addendum No 0009 - Notice to Bidders.doc DOC document
Davis Bacon UT080038 —
ASP Addendum 0008.doc DOC document
ASP Addendum 0008 RFIs.doc DOC document
Davis Bacon UT080059 —
ASP Addendum 0007.doc DOC document
ASP Addendum 0007 Drawings Specifications.pdf PDF
ASP A-E's Addendum 3 Notice to Bidders.pdf PDF
ASP Addendum 0006.doc DOC document
ASP A-E's TOC-ADM3.pdf PDF
ASP geotechnical report.pdf PDF
BID SCHEDULE ASP CW.Revised Add 0006.doc DOC document
ASP Addendum 0006.doc DOC document
W911YP-09-B-0002-0005.doc DOC document
W911YP-09-B-0002-0004.doc DOC document
BID SCHEDULE ASP CW.Revised.doc DOC document
W911YP-09-B-0002-0002 ASP addendum.doc DOC document
UT Ammo Dwg 8-21-09 pgs 1-28.pdf PDF
UT Ammo Dwg 8-21-09 pgs 40-181.pdf PDF
ASP Site Visits Contractors.pdf PDF
UT Ammo Dwg 8-21-09 pgs 29-39.pdf PDF
J A Sole Source Telecommunications ASP.doc DOC document
Utah Ammo Specs 8-21-09.pdf PDF
W911YP-09-B-0002-0001 ASP Addendum 001.doc DOC document
Utah ARNG Camp Williams Ammo Storage Point - 95 Design Submittal PDF BINDER - 7-28-09.pdf PDF
W911YP-09-B-0002 Ammunitions Suppy Point —
20090729_UTAH_ASP_95 Plans.pdf PDF
Utah ARNG Camp Williams Ammo Storage Point - 95 Design Submittal PDF PKG - 7-28-09.pdf PDF
Show all 35

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT: UTAH ARNG, CAMP WILLIAMS, UTAH AMMO STORAGE POINT 2007/07/03 spr (WBW) 2007/07/03

SECTION 08315

SLIDING BLAST RESISTANT DOOR

Part 1 - GENERAL

1.1 Summary

A. Section Includes:

1. Sliding Blast Resistant Door, frame and components necessary for a fully integrated blast door system (located in the SIRE building only).

B. The sliding blast door unit shall be a steel blast-resistant custom-designed sliding type door with frame, and ramp type threshold, and shall be a standard product of a manufacturer specializing in this type of fabrication.

C. Related Sections:

1. Section 04220 – Concrete Masonry (CMU)

2. Section 09904 – Interior Painting

1.2 quality control

A. Manufacturer shall submit evidence of having been engaged in design and manufacture of similar blast resistant door assemblies for a minimum of (10) years.

1.3 References

A. ASTM International (ASTM):

1. B 633 - Standard Specification for Electrodeposited Coatings of Zinc on Iron or Steel B. American National Standards Institute (ANSI)

1. ANSI/ASQ Z1.4 – Sampling Procedures and Tables for Inspection by Attributes C. Underwriters Laboratories, Inc. (UL):

1. UL 752 – Standard for Safety For Bullet-Resistive Equipment.

1.4 SUBMITTALS

A. Shop Drawings:

1. Sliding Blast Door Unit:

a. Show head, jamb, and sill sections, and elevations of the doors.

B. Product Data:

1. Sliding Blast Door and Frame.

a. Manufacturer's catalog data including catalog cuts and brochures.

C. Certificates:

1. Sliding Blast Door, Frame and Associated Hardware:

a. Certification shall state that the sliding blast-door units are constructed to design standards.

D. Manufacturer's Instructions:

1. Installation

a. Printed instructions and drawings provided by the manufacturer.

E. Contract Closeout Information:

1. Operating and maintenance data.

1.5 JOB CONDITIONS

A. Coordinate electrical work with Electrical Specification Divisions.

B. Verify structural door framing for acceptability.

C. Correct deficiencies.

1.6 Warranty

A. Warranty Period: One year commencing from the date of final acceptance.

Part 2 - PRODUCTS

2.1 MATERIALS

A. Acceptable manufacturers:

1. Sliding Blast Resistant Doors:

a. Base:

1) Door-Man Mfg. Co.

b. Optional:

1) Richards-Wilcox Custom Systems Inc.

2) Overly Door Company

2. Other manufacturers desiring approval comply with Division 1.

B. Design Criteria:

1. Custom designed sliding door.

2. Door size:

4’-0”x8’-0” (nominal).

3. The door, frame and restraining hardware shall be designed to withstand a 40 PSI static load.

4. Rebound pressure shall be based on a dynamic response of the door.

5. Initial blast pressure acts to seat the door.

6. Assemblies shall resist penetration from a 2” diameter steel missile fragment at 300 fps.

7. Door does not need to be air and gas tight after the blast.

8. Assemblies shall be fire rated for 1 hr minimum.

9. Operation shall be manual with pull handles on each side of door.

10. Locking mechanism shall be provided with access from either side of the door.

C. Fabrication:

1. Assemble work using all welded construction conforming to the applicable requirements of AWS D1.1 and D1.3.

2. Construct from formed steel conforming so ASTM A366 or ASTM A569.

3. Steel plate and shapes for reinforcing and/or framing members shall conform to ASTM A36 and bars shall conform to ASTM A108 grade 1018.

4. Hardware shall be corrosion resistant steel of the appropriate design for the function intended.

5. After fabrication, remove all tool marks and surface imperfections, and dress all welded joints smooth and coat with a rust inhibitive primer.

Part 3 - EXECUTION

3.1 Storage and protection of materials

A. Store all material in a dry, controlled area to protect from weather and damage.

3.2 INSPECTION

A. Verify suitability of substrate and opening to accept installation.

B. Installation constitutes acceptance of conditions and responsibility for performance.

3.3 INSTALLATION

A. Install work in strict accordance with approved shop drawings and recommended installation instructions of the manufacturer.

B. Certified welders in accordance with AWS D1.1 and D1.3 must perform any required welding.

C. After installation, the door, the locking mechanism, and the sliding mechanism shall be adjusted for proper operation.

D. Door, frame and all associated hardware shall be field painted per Section 09904.

E. Installation shall be by manufacturer or authorized representative.

F. Provide required mounting and accessory items for complete installation.

G. Prior to occupancy, adjust door for smooth operation.

END OF SECTION

134-41048 Utah ARNG, Camp Williams, Utah DOCPROPERTY "Date Issued" \* MERGEFORMAT

Ammo Supply Point 2009 - DOCPROPERTY "Deliverable" \* MERGEFORMAT

BLAST RESISTANT DOOR

08315 - 3

File details come from the government source that posted it. Updated .