This solicitation is for the design and construction of a prefabricated metal training facility in Almaty, Kazakhstan to be used as a regional platform for training with Central Asian states. The facility will include a large conference room that can be divided into three smaller rooms with movable wall panels. The construction project value is estimated between $1 million and $5 million. The North American Industry Classification System code is 236220 for industrial building construction. The period of performance for construction is approximately 270 calendar days from notice to proceed. The solicitation is full and open competition and will result in a firm-fixed-price design-bid-build construction contract awarded to one contractor. Attachments include the solicitation document, site photos, and demolition photos. Firms must register in the System for Award Management to be considered for award. Performance and payment bonds will be required.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
В
WORKING DRAWINGS
Contract No. H92277-19-C-0004 KazCent Conference Center Bostandyk (Kalinin) Region, Zharokov Street, 210/1, Almaty City, Kazakhstan
"Integra Engineering Group" LLP
State License No. 15018832
Almaty, 2020
_февраль
1 General Information
2 1st Floor Fire Alarm Plan
3 Mezzanine Floor Fire Alarm Plan
4 1st Floor Public Adress/General Alarm Plan
5 Mezzanine Floor Public Adress/General Alarm Plan
6 1st Floor Structural Cabling System Plan
7 Mezzanine Floor Structural Cabling System Plan
8 Audio/Visual System. Visual Equipment Plan
9 Audio/Visual System. Audio Equipment Plan
10 Fire Alarm and Public Adress/General Alarm Riser Diagrams
11 Structural Cabling System Riser Diagram
List of Main Set of Working Drawings
Sheet Description Note
References
SP RK 2.02-102-2012 Fire automation systems for buildings and structures
SP RK 2.02-104-2014
Standards of automatic fire detection, fire-fighting and fire alarm systems to be installed in buildings, rooms and structures.
SP RK 2.02-07-2012 Fire automation systems for buildings and structures. Guidelines.
GOST 21.101-97 Main requirements to design and working documentation
SN RK 3.02-10-2010
Installation of cummunications, alarm and utility control systems residential and public buildings. Design standards.
Attachments
LC.SO Equipment Specification on 2 sheets
List of References and Attachments
Code Description Note on 2 sheets
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
Format А3
H92277-19-C-0004 - LC
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
General Information (Start)
LC-1.1 11
Norm.Control Celebi B.
Low Current Design
A p p ro v e d
This design has been developed in accordance with the codes applicable in the Republic of Kazakhstan, and ensures the safety of human life and health in the period of the facility operation subject to the implemenation of measures provided in drawings
Chief Project Engineer ______________ Orazalin K.K.
09.19
09.19
09.19
C h a p te r A R
S a la m a to v .1
C h a p te r T E
S a la m a to v .1
C h a p te r E O M
S a d y ro v .1
Ch ap te r H V A C
Is a e v a
.1
GIP 09.19Orazalin K.
EXPLANATORY NOTE CONTENT
1. General Information
2. Fire Alarm System
3. Public Address/General Alarm System
4. Structured Cable System
5. Back Up Power System
6. Grounding
1. GENERAL INFORMATION
1.1. This project is developed based on the contract, construction drawings, documents provided by the customer, pre-design survey data, and current normative documents.
1.2. This section of the project provides the systems of automatic fire alarm system, notification system, and evacuation management system for the building of Kazcent Conference Center located on Bostandyk (Kalinin) Region, Zharokov Street 210/1 Almaty Kazakhstan.
2. FIRE ALARM SYSTEM
2.1 Main Project Decisions
2.1.1. The fire alarm system is designed to detect the fire in proper time, alert people about the fire, and control engineering systems to prevent the spread of fire.
2.1.2. Installation of automatic fire alarm system is provided in all spaces, except the bathroom units, ventilation shafts, vestibules, and spaces with wet process.
2.1.3. As a fire alarm instruments, receiving and control devices are provided in protected spaces with the following device: FlexES Control Esser FX808392, with the brand of Esser by Honeywell. The control panel will be installed in the office room located in first floor. (Room №114).
2.1.4. For the fire detection of the protected spaces, addressed optical smoke detectors are provided (802371) with Series IQ8Quad and addressed optical heat (OT) detectors with multi sensors are provided (802373) with Series IQ8Quad.
2.1.5. Manual fire detectors are provided in the mean of egress with the height of 1.2 meters from the floor finish.
2.1.6. The choice of the type of fire detectors depends on the purpose of the area, type of fire load, and the fire factor at the initial stage of the fire.
2.1.7. Loops of the fire alarm system is connected to fire alarm control panel FlexES Control Esser
FX808392.
2.1.8. In case of detection of fire, a signal will be provided via modules of IQ8TAL(804868) in order to deactivate the ventilation system and activate the smoke purge system and sound notification by sound and flashing lights.
2.2. Installation Works
2.2.1. Loops of fire alarm system of protected spaces shall be laid separately from all power, lighting cables and wires.
2.2.2. In case of open parallel laying, the distance between the cables of fire alarm loops and power/lighting cables shall be 0.5 meters at minimum. In case of necessity of laying these cables with a distance of less than 0.5 meters, they have to be protected from any electromagnetic interference. It is allowed to reduce the distance up to 0.25 m between the wires and cables of fire alarm loops and signal lines without any protection from electromagnetic interference.
2.2.3. Automatic fire alarm loops in the room shall be laid in a decorative PVC cable trays on the walls and ceilings or installed within wall structures or above the ceilings in the corrugated wire 1x2x0, 8+0.8 JH(st)H FE180.
2.2.4 Fire alarm system integrator will provide sequence of operation and programming for fie alarm system.
Documentation shall be provided on As-Builts, owner's manual, and system documentation submittals.
2.2.5 Fire alarm system integrator will configure and program appropriate sensor devices in accordance to HN and local fire protection codes and regulations. Contractor will provide as-built fire alarm riser diagram to Owner.
3. PUBLIC ADDRESS/GENERAL ALARM SYSTEM
3.1. Main Project Decisions
3.1.1. In accordance with SNiP RK 2.02-11-2002, Annex B, «Standards for the Design of Notification to People about Fire in Buildings and Structures» (Clause 1.1 Table 1), in this type of building it is required to provide 2nd type of notification system, which includes the following mandatory notification methods:
- Sounds (Announcement, tinted calls etc.);
- 'Exit' signs and lights;
- Priority of Notification:
- All people at the same time;
3.1.2. Public address system is aimed to notify staff and visitors in case of fire and other emergency situations.
3.1.3. Notification of fire event to people is transmitted by a pre-recorded announcement done automatically upon the receipt of the signal from the fire alarm system with giving a pre-recorded voiced information about fire, necessity of evacuation, mean of egress, direction of egress, and other necessary actions required for the life safety.
Notification system shall work for a time period which is necessary for the completion of evacuation from the building.
3.1.4. Transmission of announcement via speakers shall be performed from the station of sound notification (583362.22.ES+ 580212.03.ES), which is installed in Room № 114.
3.1.5. Wall mounted speakers Honeywell 581270 (6Вт/3Вт/1,5Вт) are installed on walls or structures at open ceilings. Recessed speakers Honeywell 581263 (6Вт/3Вт/1,5Вт) are installed in acoustical or gypsum board ceilings.
3.1.6. Wall-mounted speakers shall be located with an exact location so that their upper part shall be at least 2.3 m from the floor finish level, but the distance from the ceiling level to the upper part of the speaker shall be at least 150 mm at the same time.
3.1.7. Speakers does not need to have volume control and shall be connected to the main system without any plug-in devices.
3.2. Installation Works
3.2.1. Installation works shall be performed in accordance with the drawings and the manufacturer's instructions. All cables shall be marked. Marks shall be water resistant, easy-readible, and unique.
Cabling works shall be performed with 2х1,5мм2 LIHCH FE 180 type of cables and shall be laid in pipes or metal trays for low-current systems.
4. STRUCTURED CABLED SYSTEM
4.1. Main Project Decisions
4.1.1. Project provides a structured cable system in order to provide a transfer of data and connection to Internet.
4.1.2. In storage room №118, information board is installed. Data outlets are located in different working locations of the building and consist of one or two sockets (RJ45) with Category 5е.
4.1.3. Also, WiFi system is provided ehich covers the areas of conference halls and lobby. WiFi routers are installed on ceilings.
4.1.4. Cables are laid in corrugated pipes which is installed inside of walls or above the ceiling as hidden.
4.1.5. Equipment and materials specified in the project can be replaced with the similar ones, provided that they meet the minimum standards and are approved by the Customer.
5. BACK UP POWER SYSTEM
In accordance with PUE, fire alarm system is supported with the power supply of 1st category. Therefore, the power supply of the fire alarm system must be provided from two independent AC sources with a voltage of 220V, with a frequency of 50 Hz and at least 0.9 kW each; or from a single AC source with an automatic switching option during emergency mode to provide back up power from batteries.
6. GROUNDING
In order to provide life safety, all electrical equipments shall be grounded in accordance with the regulations of PUE. Installation of all grounding devices shall be performed in accordance with the manufacturer's recommendations. The resistance of the grounding devices shall not exceed 4 Ohms. Grounding and protective earth connectors shall be connected with bolted connections. During the provision of grounding, third core of power cable shall be used.
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
Format А3
H92277-19-C-0004 - LC
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
General Information (End)
LC-1.2 11
Norm.Control Celebi B.
Low Current Design
A p p ro v e d
09.19
09.19
09.19
C h a p te r A R
S a la m a to v .1
C h a p te r T E
S a la m a to v .1
C h a p te r E O M
S a d y ro v .1
Ch ap te r H V A C
Is a e v a
.1
GIP 09.19Orazalin K.
5850 5850 5850 3635 2805
29250
1 2 3 4 5 6
А
Б
В
±0.000
105 106 107 111
118 108 116 117
88.16 51.08 50.10
5.71 3.90 6.46 6.24
9.46
9.62
2.89 4.04
15.37
8.65 9.80
8.40
7.89
84.50
115120 114
5.78
3.87
+0.920
6.16
5/14/1
2215 3045
А/1
Б/2
5%
5%
5%
5%
6 x 153 = 920
6 x 153 = 920
18 x 194 = 3 500
Б/1
326 230
Detail A
PA/GA panel
FA panel
BTH1.45
F - 1x2x0,8+0,8mm2
JH(st)H FE180
S - 1x2x0,8+0,8mm2
JH(st)H FE180
S1
S4S5
S3
S, F
S, F
F
F
S
F
F
I/O
I/O
BTM1.39
BTM1.50
BTM1.61
BTM1.66
BTM1.73
BTM1.74
BTH1.44
BTH1.40-43
BTH1.46
BTH1.47
BTH1.48
BTH1.49
I/OI/O
BTH1.99
I/O
BTM1.1
BTH1.9
BTH1.8
BTH1.7
BTH1.6 BTH1.5
BTH1.4
BTH1.3 BTH1.2
BTH1.10
BTH1.11BTH1.13
BTH1.12
BTH1.15
BTH1.14
BTH1.16
BTH1.17
BTH1.18
BTH1.19
BTH1.20
BTH1.21BTH1.22
BTH1.23
BTH1.25
BTH1.26
BTH1.27
BTH1.28
BTH1.31
BTH1.32
BTH1.33
BTH1.34
BTH1.35
BTH1.36
BTH1.37
BTH1.38
BTM1.30
BTM1.29
BTM1.24
to +3.500 from +3.500 to +3.500 to +3.500 from +3.500 from +3.500 from +3.500 from +3.500 to +3.500 to +3.500
F
S
Detail A
UPSI/O
BTH1.100
BTH1.101
BTH1.102
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
1st Floor Fire Alarm Plan
Legend
Fire alarm panel
Fire alarm detector
Heat detector
Fire alarm manual call point
Siren/Flasher
Note: Fire alarm manual call point mounting height is
1500mm from FFL unless notified other
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-2 11
1-st Floor Plan ±0.000
Sc: 1/100
Fire alarm module
Cloakroom
Lobby Area
Vestibule
Conference Room 1
Translator Booth 1
No. Space Description Net m2
Restroom Entrance Hall
Restroom (Men)
Conference Room 2
Conference Room 3
Translator Booth 2
Restroom (Woomen)
Staff Office
Janitor Closet
Restroom (Disabled)
Storage (CF 1)
Total NET Area
Storage (CF 2)
Storage (CF 3)
Service & Storage (Lobby)
Mechanical Room
Electrical Room
7.89
84.50
8.65
88.16
51.08
50.10
9.62
3.90
8.40
15.37
9.46
4.04
2.89
6.16
5.78
6.46
6.24
5.71
9.80
3.87
388.08
Emergency call button Norm.Control Celebi B.
09.19
09.19
09.19
I/O
Smoke detector with remote indicator(celling)
+3.500
58.76
8.07
5.25
2.32
±0.000+0.920
5850 5850 5850 3635 2805
29250
1 2 3 4 5 6
А
Б
В
5/14/1
2215 3045
А/1
7.85
Б/2
±0.000
±0.000
±0.000
18 x 194 = 3 500
Б/1
S2
F F
F F
F
F
S, F
S, F
S
S
F - 1x2x0,8+0,8mm2
JH(st)H FE180
S - 1x2x0,8+0,8mm2
JH(st)H FE180
BTK1.84
BTH1.83
BTK1.85
BTH1.86
BTH1.88
BTH1.87
BTH1.89
BTH1.90
BTH1.81
BTH1.80
BTH1.79
BTH1.78
BTH1.91
BTH1.92
BTH1.93
BTH1.94
BTH1.95
BTH1.96
BTH1.97
BTH1.98
BTH1.76
BTH1.75BTH1.68
BTH1.67
BTH1.70
BTH1.69
BTH1.71
BTH1.72BTH1.62
BTH1.63
BTH1.64
BTH1.65
BTH1.58
BTH1.57
BTH1.56
BTH1.55BTH1.54
BTH1.53
BTH1.52
BTH1.51
BTH1.59
BTH1.60
BTM1.77
BTM1.82
from ±0.000 from ±0.000 to ±0.000 from ±0.000 from ±0.000 from ±0.000 to ±0.000 to ±0.000 to ±0.000 to ±0.000
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Mezzanine Floor Fire Alarm Plan
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-3 11
Mezzanine Floor Plan +3.500
Sc: 1/100
Restroom (Mezzanine)
Kitchenette
Mezzanine Lounge
Storage (Mezzanine)
No. Space Description Net m2
Lobby Mezzanine
Total NET Area
58.76
7.85
2.32
8.07
5.25
82.25
Norm.Control Celebi B.
09.19
09.19
09.19
Legend
Fire alarm panel
Fire alarm detector
Heat detector
Fire alarm manual call point
Siren/Flasher
Note: Fire alarm manual call point mounting height is
1500mm from FFL unless notified other
Fire alarm module
Emergency call button
I/O
29250
1 2 3 4 5 6
А
Б
В
±0.000
105 106 107 111
118 108 116 117
88.16 51.08 50.10
5.71 3.90 6.46 6.24
9.46
9.62
2.89 4.04
15.37
8.65 9.80
8.40
7.89
84.50
115120 114
5.78
3.87
+0.920
6.16
5/14/1
2215 3045
А/1
Б/2
5%
5%
5%
5%
6 x 153 = 920
6 x 153 = 920
18 x 194 = 3 500
Б/1 to +3.500
2x1.5 mm2 LIHCH
UPS
BIAD1
BIAD2
BIAD3
BIAD4BIAD5BIAD6
BIAD7
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
1st Floor Public Adress/General Alarm Plan
Legend
Public adress/general alarm panel
Recessed ceiling type speaker
Surface mounted speaker "Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-4 11
1-st Floor Plan ±0.000
Sc: 1/100
Cloakroom
Lobby Area
Vestibule
Conference Room 1
Translator Booth 1
No. Space Description Net m2
Restroom Entrance Hall
Restroom (Men)
Conference Room 2
Conference Room 3
Translator Booth 2
Restroom (Woomen)
Staff Office
Janitor Closet
Restroom (Disabled)
Storage (CF 1)
Total NET Area
Storage (CF 2)
Storage (CF 3)
Service & Storage (Lobby)
Mechanical Room
Electrical Room
7.89
84.50
8.65
88.16
51.08
50.10
9.62
3.90
8.40
15.37
9.46
4.04
2.89
6.16
5.78
6.46
6.24
5.71
9.80
3.87
388.08
Norm.Control Celebi B.
09.19
09.19
58.76
8.07
5.25
2.32
±0.000+0.920
5850 5850 5850 3635 2805
29250
1 2 3 4 5 6
А
Б
В
5/14/1
2215 3045
А/1
7.85
Б/2
±0.000
±0.000
±0.000
18 x 194 = 3 500
Б/1 from ±0.000
BIAD8
BIAD9 BIAD10
BIAD11
BIAD12 BIAD13
BIAD14
BIAD15
BIAD16
BIAD17
BIAD18
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Mezzanine Floor Public Adress/General Alarm
Plan
Legend
Public adress/general alarm panel
Recessed ceiling type speaker
Surface mounted speaker "Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-5 11
Mezzanine Floor Plan +3.500
Sc: 1/100
Restroom (Mezzanine)
Kitchenette
Mezzanine Lounge
Storage (Mezzanine)
No. Space Description Net m2
Lobby Mezzanine
Total NET Area
58.76
7.85
2.32
8.07
5.25
82.25
Norm.Control Celebi B.
09.19
29250
1 2 3 4 5 6
А
Б
В
±0.000
105 106 107 111
118 108 116 117
88.16 51.08 50.10
5.71 3.90 6.46 6.24
9.46
9.62
2.89 4.04
15.37
8.65 9.80
8.40
7.89
84.50
115120 114
5.78
3.87
+0.920
6.16
5/14/1
2215 3045
А/1
Б/2
5%
5%
5%
5%
6 x 153 = 920
6 x 153 = 920
18 x 194 = 3 500
Б/1
WiFi
Rack
T1 T2 T3
T4
T5
T6
T7
T8 T9
T10
D1
D2
D3
D4
D5
D6
D7
D8 D9
D10
W1 to +3.500
31x(UTP cat.5e)
4x(UTP cat.5e)
2x(UTP cat.5e)
2x(UTP cat.5e)
2x(UTP cat.5e)
2x(UTP cat.5e)
3x(UTP cat.5e)
7x(UTP cat.5e)
2x(UTP cat.5e)
2x(UTP cat.5e) from +3.500 10x(UTP cat.5e)
UTP cat.5e from +3.500 2x(UTP cat.5e) from +3.500 2x(UTP cat.5e)
4x(UTP cat.5e)
8x(UTP cat.5e) 4x(UTP cat.5e)
D11 D12 D13 D14
D15 D16 D17 D18
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
1st Floor Structural Cabling System Plan
Legend
Recessed telecom socket RJ45
Recessed data socket RJ45
Rack cabinet
Note: Data/Telecom sockets mounting height is 300mm from FFL unless notified other
Rack
Floor box for 18 modules
LC-6 11
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
1-st Floor Plan ±0.000
Sc: 1/100
Cloakroom
Lobby Area
Vestibule
Conference Room 1
Translator Booth 1
No. Space Description Net m2
Restroom Entrance Hall
Restroom (Men)
Conference Room 2
Conference Room 3
Translator Booth 2
Restroom (Woomen)
Staff Office
Janitor Closet
Restroom (Disabled)
Storage (CF 1)
Total NET Area
Storage (CF 2)
Storage (CF 3)
Service & Storage (Lobby)
Mechanical Room
Electrical Room
7.89
84.50
8.65
88.16
51.08
50.10
9.62
3.90
8.40
15.37
9.46
4.04
2.89
6.16
5.78
6.46
6.24
5.71
9.80
3.87
388.08
Norm.Control Celebi B.
09.19
09.19
09.19
AutoCAD SHX Text 18M
AutoCAD SHX Text 18M
AutoCAD SHX Text 18M
AutoCAD SHX Text 18M
58.76
8.07
5.25
2.32
±0.000+0.920
5850 5850 5850 3635 2805
29250
1 2 3 4 5 6
А
Б
В
5/14/1
2215 3045
А/1
7.85
Б/2
±0.000
±0.000
±0.000
18 x 194 = 3 500
Б/1
WiFiWiFi
WiFi
WiFi h=7000mm
Projector
T11
D19
D20 D21
D22
D23
W2 W3 W4
W5 from ±0.000
Projector
Projector
Projector h=7000mm h=7000mm h=7000mm
31x(UTP cat5e) to ±0.000 2x(UTP cat.5e) to ±0.000 9x(UTP cat.5e) to ±0.000 2x(UTP cat.5e)
2x(UTP cat.5e)
10x(UTP cat.5e) 9x(UTP cat.5e)
UTP cat.5e UTP cat.5e UTP cat.5e
UTP cat.5e
UTP cat.5e
UTP cat.5e
UTP cat.5e
UTP cat.5e
2x(UTP cat.5e)31x(UTP cat.5e) 28x(UTP cat.5e) 27x(UTP cat.5e) 25x(UTP cat.5e) 14x(UTP cat.5e) 13x(UTP cat.5e) 12x(UTP cat.5e)
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Legend
Recessed telecom socket RJ45
Recessed data socket RJ45
Rack cabinet
Note: Data/Telecom sockets mounting height is 300mm from FFL unless notified other
Rack
Floor box for 18 modules
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Mezzanine Floor
Structural Cabling System Plan
LC-7 11
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
Mezzanine Floor Plan +3.500
Sc: 1/100
Restroom (Mezzanine)
Kitchenette
Mezzanine Lounge
Storage (Mezzanine)
No. Space Description Net m2
Lobby Mezzanine
Total NET Area
58.76
7.85
2.32
8.07
5.25
82.25
Norm.Control Celebi B.
09.19
09.19
09.19
58.76
8.07
5.25
2.32
±0.000+0.920
5850 5850 5850 3635 2805
29250
1 2 3 4 5 6
А
Б
В
5/14/1
2215 3045
А/1
7.85
Б/2
±0.000
±0.000
±0.000
18 x 194 = 3 500
Б/1
Rack
Cabinet
2xHDMI cable
Rack
Cabinet
XLR cable
2xXLR cable
Rack
Cabinet
XLR cable
2xXLR cable
2xHDMI cable 2xHDMI cable
2xHDMI cable
XLR cable
XLR cable
2xXLR cable
Projection device Projection device
Projection device
Projection device
SiSTEMi (2 DiL)
220VAC
220VAC
Motorized projection screen
Projection device
CENTRAL
EQUIPMENT
DVD/ CD/ MP3 Player x H D M I ca b le
Ceiling speaker
2x1.5mm2 LIHCH
X L R c a b le
Ceiling speaker
Ceiling speaker
Ceiling speaker
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Audio/Visual System.
Visual Equipment Plan
Legend
Rack cabinet
Projection device
Floor box "Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-8 11
Mezzanine Floor Plan +3.500
Sc: 1/100 Restroom (Mezzanine)
Kitchenette
Mezzanine Lounge
Storage (Mezzanine)
No. Space Description Net m2
Lobby Mezzanine
Total NET Area
59.20
7.82
2.32
8.72
5.25
83.31
Norm.Control Celebi B.
09.19
09.19
09.19
AutoCAD SHX Text 18M
AutoCAD SHX Text 18M
AutoCAD SHX Text 18M
AutoCAD SHX Text 18M
58.76
8.07
5.25
2.32
±0.000+0.920
5850 5850 5850 3635 2805
29250
1 2 3 4 5 6
А
Б
В
5/14/1
2215 3045
А/1
7.85
Б/2
±0.000
±0.000
±0.000
18 x 194 = 3 500
Б/1
Rack
Cabinet
Ceiling speaker
2x1.5mm2 LIHCH 2x1.5mm2 LIHCH
2x1.5mm2 LIHCH
2x1.5mm2 LIHCH
Rack
Cabinet Rack
Cabinet
2x1.5mm2 LIHCH 2x1.5mm2 LIHCH
Ceiling speaker
Ceiling speaker
Ceiling speaker
Ceiling speaker
Ceiling speaker
Ceiling speaker
Ceiling speaker
Ceiling speaker
Ceiling speaker
2x1.5mm2 LIHCH
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Mezzanine Floor Plan +3.500
Sc: 1/100
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
Format А2
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Legend
Rack cabinet
Recessed ceiling type speaker
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-9 11
Audio/Visual System.
Audio Equipment Plan
Restroom (Mezzanine)
Kitchenette
Mezzanine Lounge
Storage (Mezzanine)
No. Space Description Net m2
Lobby Mezzanine
Total NET Area
58.76
7.85
2.32
8.07
5.25
82.25
Norm.Control Celebi B.
09.19
1s t F lo o r
M e z z a n in e F lo o r
From Fire alarm panel 220V
UPS
PA/GA panel
PA/GA Riser Diagram
2x1.5mm2 LIHCH
№102 №110 №111 №106 №105 №104 №119
№104№104№105№105№102№102№106№106№201№201№202
BTH1.10-15
BTH1.51-58BTM1.61BTH1.69-72BTH1.75-76
1x2x0,8+0,8мм2 JH(st)H FE180
1x2x0,8+0,8мм2 JH(st)H FE180
S1 S3 S4 S5 S6
№102 №102 №106 №105 №104
№114№102 №115 №109 №107 №117 №106 №116 №105 №104
I/O
BTH1.25-28
№108 №118 №119 №120 №120 №103 №104
№104№102№102
BTH1.62-65
№105
BTM1.66
№105
BTH1.67-68
№102№106
BTM1.73
№106
BTM1.74
№102№102
BTM1.77
№201
BTH1.78-81
№201
BTM1.82
№201№202№201№102№204
S2
№201
I/O №112
№112
BTM1.1 BTH1.2-5 BTH1.6-9 BTH1.16-19 BTH1.20-23 BTM1.24 BTM1.29 BTM1.30 BTH1.31-34 BTH1.35-38 BTM1.39 BTH1.40-43 BTH1.44-45 BTH1.46-49 BTM1.50
BTH1.59-60BTK1.84-85
BTН1.83,86
BTH1.87-90BTH1.91-94BTH1.95-98
BTH1.99
220V
UPS
Fire alarm panel Fire Alarm Riser Diagram
BIAD8 . . . . . BIAD18
BIAD1 . . . . . BIAD7
UPS
№113
BTH1.101-102
I/O №114
BTH1.100
1(-)Input 2(-)Output 3(+)Input 4(+)Output
Bl ue
(I np ut)
Re d (
Inp ut)
Gr ou nd ing
Re d (
Ou tpu t)
Bl ue
(O utp ut)
Gr ou nd ing
(Outgoing Automatic Deactivation with Drive in Board ЩР) Signal for Deactivation of Ventilation System
Connection of Ventilation System to Fire Module IQ8TAL
НЗ
to Fire Alarm Installations
(Outgoing Automatic Deactivation in Board ЩДУ) Signal for Activation of Smoke Purge System
Connection of Smoke Purge System to Fire Module IQ8TAL
НО
to Fire Alarm Installations
Bl ue
(I np ut)
Re d (
Inp ut)
Gr ou nd ing
Re d (
Ou tpu t)
Bl ue
(O utp ut)
Gr ou nd ing
1(-)Input 2(-)Output 3(+)Input 4(+)Output
Blue (Input)
Red (Input) Red (Output)
Black (Output)
IQ8 Base (805590)
Red (Output)
Blue (Output) Blue (Output)
GroundingGroundingGrounding
EP 6
EM 2
C 3
IN 4
OUT 5
EP 6
EM 2
C 3
IN 4
OUT 5
Black (Output) x1
Cable to Next Detector
Indicator of fire detection (781814 )
Connection of Manual Detectors to Device FlexES Control
Grounding
1(-)Input 2(-)Output 3(+)Input 4(+)Output
1x2x0,8+0,8 JH(st)H FE180 from Previous Detector
Cable 1x2x0,8+0,8 JH(st)H FE180
Cable 1x2x0,8+0,8 JH(st)H FE180 from Previous Detector to Next Detector Cable 1x2x0,8+0,8 JH(st)H FE180
Blue (Input)
Red (Input)
Grounding
Red (Output)
Blue (Output)
Grounding
Connection of Smoke/Heat Detectors to Device FlexES Control
(Outgoing Automatic Deactivation with Drive in Board ЩР) Signal for Deactivation of Ventilation System
Manual Detector (804905 )
IQ8 Base (805590)
Grounding
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Format А3
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Fire Alarm Riser Diagram.
Public Adress/General Alarm Riser Diagram
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-10 11
Public adress/general alarm panel
Recessed ceiling type speaker
Surface mounted speaker
Legend
Fire alarm panel
Fire alarm detector
Heat detector
Fire alarm manual call point
Siren/Flasher
I/O Fire alarm module
Emergency call button
Norm.Control Celebi B.
09.19
09.19
D1, T1 D1, T1
2x(UTP cat.5e) - 8 (16m)
Room №118
D2, T2 D2, T2
2x(UTP cat.5e) - 8 (16m)
Room №108
D3, T3 D3, T3
2x(UTP cat.5e) - 31 (62m)
Room №116
D4, T4 D4, T4
2x(UTP cat.5e) - 39 (78m)
Room №117
D5, T5 D5, T5
2x(UTP cat.5e) - 43 (86m)
Room №107
D6, T6 D6, T6
2x(UTP cat.5e) - 44 (88m)
Room №107
D7, T7
Room №114
D8-9, T8-9
Room №104
D10, T10
Room №103
D7, T7
2x(UTP cat.5e) - 58 (116m)
D8-9, T8-9
4x(UTP cat.5e) - 16 (64m)
D10, T10
2x(UTP cat.5e) - 41 (82m)
1s t fl o o r
D19 D19
UTP cat.5e - 24 m
Room №104
D20 D20
UTP cat.5e - 31 m
Room №105
D21 D21
UTP cat.5e - 37 m
Room №106
D22 D22
UTP cat.5e - 38 m
Room №201
D23, T11 D23, T11
2x(UTP cat.5e) - 38 (76m)
Room №202
W2
Room №104
W3
Room №105
W4
Room №106
W5
Room №102
W1
Room №105
W1
UTP cat.5e - 49 m
W2
UTP cat.5e - 22 m
W3
UTP cat.5e - 29 m
W4
UTP cat.5e - 36 m
W5
UTP cat.5e - 37 m
M e z z a n in e f lo o r Rack IDF-1. Front door - glass, lockable, rear door - metal
Cable tray and cabinet connection option
Cable tray grounding clamp
Laying of cable in gypsum board walls
Gypsum board Insulation
Corrugated pipe
Profile
Cable
Wire tray mounting on profile detail
Wire tray
Profile
Screw
Serrated flange nut
Fender washer
Room №102
D11-14
Room №106
D15-18
D11-14
4x(UTP cat.5e) - 35 (140m)
D15-18
4x(UTP cat.5e) - 38 (152m)
MODE
LOCATOR
FAULT
POWER
CONSOLE
MODE
LOCATOR
FAULT
POWER
CONSOLE
24 Port Switch
RACK, 19``, 42U, 600x600mm
220V
3x2,5mm2 ВВGng-LS
01 02 03 04 0605 07 08 09 10 1211 13 14 15 16 1817 19 20 21 22 2423
01 02 03 04 0605 07 08 09 10 1211 13 14 15 16 1817 19 20 21 22 2423
24 Port Cat5e
Patch Panel
24 Port Switch
39x(Cat5e UTP)
MODE
LOCATOR
FAULT
POWER
CONSOLE
01 02 03 04 0605 07 08 09 10 1211 13 14 15 16 1817 19 20 21 22 2423
24 Port Switch
24 Port Cat5e
Patch Panel
24 Port Cat5e
Patch Panel
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
Format А3
H92277-19-C-0004 - LC
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Structural Cabling System Riser Diagram
Legend
"Integra Engineering Group KZ"
LLP
GSL No. 15018832
LC-11 11
Recessed telecom socket RJ45
Recessed data socket RJ45
Rack cabinetRack Norm.Control Celebi B.
09.19
09.19
09.19
AutoCAD SHX Text 1U
AutoCAD SHX Text 2U
AutoCAD SHX Text 3U
AutoCAD SHX Text 4U
AutoCAD SHX Text 5U
AutoCAD SHX Text 6U
AutoCAD SHX Text 7U
AutoCAD SHX Text 8U
AutoCAD SHX Text 9U
AutoCAD SHX Text 10U
AutoCAD SHX Text 12U
AutoCAD SHX Text 13U
AutoCAD SHX Text 14U
AutoCAD SHX Text 15U
AutoCAD SHX Text 16U
AutoCAD SHX Text 17U
AutoCAD SHX Text 18U
AutoCAD SHX Text 19U
AutoCAD SHX Text 20U
AutoCAD SHX Text 21U
AutoCAD SHX Text 22U
AutoCAD SHX Text 23U
AutoCAD SHX Text 24U
AutoCAD SHX Text 25U
AutoCAD SHX Text 26U
AutoCAD SHX Text 27U
AutoCAD SHX Text 28U
AutoCAD SHX Text 29U
AutoCAD SHX Text 30U
AutoCAD SHX Text 31U
AutoCAD SHX Text 32U
AutoCAD SHX Text 33U
AutoCAD SHX Text
19``BOARD-3.4
AutoCAD SHX Text 34U
AutoCAD SHX Text 35U
AutoCAD SHX Text 36U
AutoCAD SHX Text 37U
AutoCAD SHX Text 38U
AutoCAD SHX Text 39U
AutoCAD SHX Text 40U
AutoCAD SHX Text 41U
42U
Item Description and technical specification Type, brand, code of document, data sheet
Code of equipment, product, material
Factory
(for imported equipment country, company)
Meas.
unit Qty.
Unit weight, kg Note
1 2 3 4 5 6 7 8 9
Automatic fire alarm
1. Main equipment
1.1 Fire alarm panel pcs 1
1.2 Fire alarm detector pcs 82
1.3 Heat detector pcs 2
1.4 Fire alarm manual call point pcs 12
1.5 Siren/Flasher pcs 6
1.6 Fire module pcs 6
1.7 Emergency call button pcs 1
1.8 Indicator of fire detector in the ceiling pcs 41
1.9 UPS(15min.) 900W/220V
2. Cabling and wiring products
2.1 Cable 1x2x0.8+0.8mm2 JH(st)H FE180 m 2000
2.2 Cable 3x1.5mm2 JH(st)H FE180 m 400
2.3 ∅20 PVC HF flexible conduit m 2000
Public adress/General alarm system
1. Main equipment
1.1 Public adress/General alarm panel pcs 1
1.2 Power amplifier pcs 1
1..3 Recessed ceiling type speaker pcs 17
1.4 Surface mounted speaker pcs 1
2. Cabling and wiring products
2.1 Cable 2x1 .5mm2 LIHCH-FE180 m 300
2.2 ∅20 PVC HF flexible conduit m 300 pcs 1
Esser by honeywell
Esser by honeywell
Esser by honeywell
Esser by honeywell
Esser by honeywell
Esser by honeywell
Esser by honeywell
FX808392
804905+704900
805590+802373
805590+802371
VALKYRIE CBS
804868+704981
Esser by honeywell781814
APC
Esser by honeywell 580212.03.ES
Esser by honeywell581263
Esser by honeywell581270
583362.22.ES Esser by honeywell
Stage Sheet Sheets
Qty. Doc.NoRev. Sheet Sign. Date
Drawn by
Checked by
WD
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Format А3
H92277-19-C-0004 - LC.SO
Low Current Design
Facility: KazCent Conference Center
Address: Almaty City, Kazakhstan, Bostandyk (Kalinin) Region, Zharokov Street, 210/1
Sadyrov M.
Kamchybekov A.
Equipment Specification
LC.SO-1 2
"Integra Engineering Group KZ"
LLP
GSL No. 15018832Norm.Control Celebi B.
09.19
Item Description and technical specification Type, brand, code of document, data sheet
Code of equipment, product, material
Factory
(for imported equipment country, company)
Meas.
unit Qty.
Unit weight, kg Note
1 2 3 4 5 6 7 8 9
Telecommunication Legrand/HP
1. Main equipment
1.1 Data rack cabinet 19" 42U 800х800, with black glass front door and on wheels pcs 1
1.2 Patch panel 24port Cat5e pcs 3
1.3 Switch 24 port 1GB PoE pcs 3
1.4 Data socket RJ45 pcs 28
1.5 Data socket RJ45 for floor box pcs 4
2. Cabling and wiring products
2.1 UTP cat.5e m 1500
2.2 ∅20 PVC HF flexible conduit m 1400
2.3 Accessory materials set 1
Audio Video system
1. Main equipment
1.1 Interpretation equipment set 1
1.2 Central equipment set 3
1.3 Projector device set 4
1.4 Projector screen motorized set 3
1.5 Projector screen set 1
1.6 Ceiling type speaker pcs 10
1.7 Rack cabinet 12U set 3
1.8 Touch screen device (portable) set 1
2. Cabling and wiring products
2.1 Cable 2x1 .5mm2 LIHCH m 200
2.2 UTP cat.5e m 300
2.3 XLR, L=20m pcs 12
2.4 HDMI, L=20m pcs 12
ITK
ITK
HP
ITK
Legrand/Mosaic
LN05-42U88-G
PP24-1UC5U-D05
J9980A
076551
UTP
d20mm
BOSCH
BOSCH
BOSCH
BOSCH
ITK
ADEOGROUP
VIVITEK
ADEOGROUP
ITK
ЕКF
O ri g In v N o
S ig n a n d D a te
R e p l.
I n v N o
Format А3
Sheet
Qty. Doc.NoRev. Sheet Sign. Date
LC.SO-2
H92277-19-C-0004 - LC.SO