LEVEL ONE
100' - 0"
LEVEL TWO
112' - 0"
LEVEL THREE
123' - 4"
LEVEL ROOF
134' - 8"
11'-0 1/2"
3/4"
10'-8"
3/4"
10'-8"
3/4"
11'-1 1/4"
2'-4"
3'-4"5'-5 1/4" 3'-8"3'-4"
3'-8"
8"
3'-4"7'-0 1/2"
LEVEL ONE
100' - 0"
LEVEL TWO
112' - 0"
LEVEL THREE
123' - 4"
LEVEL ROOF
134' - 8"
10"
3/4"
8' - 0"
3/4"
6' - 9 1/2"
3/4"
8' - 0"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
3' - 11 3/4"
3/4"
1' - 4" 7' - 6"
1' - 10"
3' - 0" 3' - 4" 4' - 4" 3' - 0" 3' - 4" 4' - 4"
3' - 0" 3' - 4" 4' - 4"
3' - 0" 3' - 4" 4' - 4"
2' - 8 1/2"
7'-10"
LEVEL ONE
100' - 0"
LEVEL TWO
112' - 0"
LEVEL THREE
123' - 4"
LEVEL ROOF
134' - 8"
10' - 4" 7' - 6"
3/4"
7' - 10 1/2"
3/4"
7' - 6" 10' - 4"
2' - 0"
3' - 4"
2' - 2" 2' - 0"
3' - 4"
2' - 2"
4' - 0"3' - 4"3' - 0"
2' - 3 1/4"
3' - 4"
2' - 3 1/4"
W3 W3 W3
W3W3
W3
W3
W3
W2
3'-10"
LEVEL ONE
100' - 0"
LEVEL TWO
112' - 0"
LEVEL THREE
123' - 4"
LEVEL ROOF
134' - 8"
3/4"
10' - 5"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
10' - 8"
3/4"
5' - 9"
3/4" 10"
3' - 3" 3' - 4" 3' - 10" 3' - 6" 3' - 4" 3' - 10" 3' - 6" 3' - 4" 3' - 10" 3' - 6" 3' - 4" 3' - 10"
3' - 6" 3' - 4" 3' - 10" 3' - 6" 3' - 4" 3' - 10"
LEVEL TWO
112' - 0"
3' - 4"
LEVEL ONE
100' - 0"
3' - 4"
AS302
EXTERIOR ELEVATIONS
1/8" = 1'-0"
EXTERIOR ELEVATION COURTYARD FACING SOUTH
1/8" = 1'-0"
EXTERIOR ELEVATION COURTYARD FACING WEST
1/8" = 1'-0"
EXTERIOR ELEVATION COURTYARD FACING NORTH
1/8" = 1'-0"
EXTERIOR ELEVATION COURTYARD FACING EAST
1/4" = 1'-0"
WDW TYPE W2 ELEVATION
1/4" = 1'-0"
WDW TYPE W1 ELEVATION
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Dwg.
Office of
Construction and Facilities
Management
100% CD NOVEMBER 8, 2017
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h o n e f o o t t h r e e i n c h e s o n e f o o t
FULLY SPRINKLED
of
COMPLETE CONSTRUCTION
1ST & 2ND FLOOR B405
VAS JE/BH07/25/2017
676-18-107
VA MEDICAL CENTER TOMAH, WI
No. Revisions Date
KEYED NOTES
RETROFIT EXISTING W2 STYLE WINDOW TO W1 STYLE WINDOW. WILL
REQUIRE INTEGRAL BLINDS, NEW INTERIOR WINDOW PANNING, AND
A THIRD PANE OF GLAZING.
1 1
1 1
1 1
1 1
1 1 1
ACCOMPANYING AMENDMENT VA69D-18-B-1687 00005
AutoCAD SHX Text RETROFIT EXISTING EFCO WINDOWS TO RECEIVE A THIRD PANE OF GLASS AND INTEGRAL BLINDS (TYPICAL AT ALL COURTYARD BEDROOM WINDOWS)
AutoCAD SHX Text RETROFIT EXISTING EFCO WINDOWS TO RECEIVE A THIRD PANE OF GLASS AND INTEGRAL BLINDS (TYPICAL AT ALL COURTYARD BEDROOM WINDOWS)
AutoCAD SHX Text RETROFIT EXISTING EFCO WINDOWS TO RECEIVE A THIRD PANE OF GLASS AND INTEGRAL BLINDS (TYPICAL AT ALL COURTYARD BEDROOM WINDOWS)