VA69D-18-B-1687-00005002.pdf
PDF 922 KB Posted
- Attached to
- Complete Construction 1st & 2nd floors B405 Project# 676-18-107 Tomah VA Medical Center, Tomah, WI
- Solicitation number
- VA69D18B1687
About this file
VA69D-18-B-1687 00005 S06 - Amend 00005 - B405-AS704-Pre-Bid_revision.pdf
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PP
PP
7 8 10
G
H
W2
LOUNGE
CORR.
1C01
KITCHEN
PANTRY
AS704
COMM.
CORR.
1C03
PARTITION TYPE F2A
INFILL WINDOW
OPENING.
2' - 0" 21' - 4" 2' - 0" 10' - 0" 13' - 6"
W3
W3
1555.1
5'-2 3/4" 1'-6 3/4" 8'-8 3/16" 7'-0"
1SA4A
A4A
A8
A4A
A4A
A4A
F
6 9 11
BEDROOM E
BTH. RM
1507A
E Q
E Q
A8A
1/2A6A
1/2A4A
1/2A4A
1/2A6A
(2) CH
AS704
C6A
AS701
5107A
W2
A4A
1/2A4A
A4A
A4A
CG
1/2A4A
FEC
CCT1
6' - 0 1/4" 3' - 4" 3' - 8 1/2"
TV
8' - 6" 8' - 3 1/4"
F4
1A4A
A4
9" 1'-6"
2' - 10" 2' - 0"
AS930
A8A
A8A
TRACK MOUNTED
BAR STYLE
DOORS
7 8 10
G
H
W2
2557 2559
LOUNGE
CORR.
2C01
CORR.
2C03
BEDROOM A
HAC CLO
STOR
2' - 0" 21' - 4" 2' - 0" 10' - 0" 13' - 6"
7' - 7"
6"
A4A 1A4A
1SA4A-CT
1A4A
1A4A
AS704
F
6 9
A4A
A4A
A4A
8' - 8" 7' - 3"1' - 7 3/8"
1SA4A-CT
ALIGN
2507.1
W3 W3
W3
ADMIT/CONSULT
A4A
7' - 10 7/8"
6"
COMM.
MOP SINK
AS704
2' - 10" 2' - 0"
AS930
TRACK MOUNTED
BAR STYLE
DOORS
STOR
LAUNDRY VEST.
OFFICE/MEETING
TOILET
5 7
J
K
1C01.1
1554 1C01.2
9'-11 1/4" 1'-6 3/4" 3'-11 3/4" 5 1/4" 7'-0"
5"
1A4A
A4A 1/2A4A
A4A
L
6"
1'-0"
F4F4
DCS
5"
(2) CH
AS704
A8A
A4A
A4A
F4
1/2A4A
A4A
10'-0" 2'-0"
EQ EQ
4 5
STACKED WASHER/DRYERS
DISH-
WASHER
34.5
24 24
34.5
36 24
34.5
24 24
DOUBLE
OVEN/RANGE
SLOPED
TOP
WINDOW
RANGE
HOOD
WINDOW WINDOW
5 3/4"
6"
1' - 9"6"
FEC
2' - 1 1/2"
6" CONC. BASE
BY G.C.,
FINISHED W/
WALL BASE TO
MATCH ROOM
4'-3" SFT.
4'-3"
KEYSWITCH
L L
L L L
L
REFRIGERATOR
WD FRAMED
OPENING (BARN STYLE DOORS)
34.5
15 24
34.5
36 24
SLOPED TOP
7'-0"
A4
8' - 6" 6"5' - 11 3/4"6"
1"
TOP TYPE 3
L L
L L
34.5
36 24
0"
L
SLOPED TOP
32.5
36 24
32.5
27 24
32.5
30 24
COFFEE
MAKER
REFRIGERATOR
MICROWAVE
OVEN
ICE MAKER IN
REFRIGERATOR
L L
L
L
L
L
DESK - 36"
BED
WS
1'-0"6'-0"6"
G
F
PANTRY
BEDROOM E
BTH. RM
5107A
CORR
1C02
CCT1
A.F.F.
GYB
8' - 0"
A.F.F.
GYB
8' - 0"
2X2 AP TO ALIGN
WITH FCU WHERE
NOTED ON RCP
N
S
METAL COUNTER
TOP SUPPORT
BRACKETS.
TOP
TYPE 2
MOP SINK
RSV (WALL GUARD)
BACK AND SIDE WALL
UTILITY
SHELF
BASE
SDISP - VFCI
3'-0"
BASE
RSV (WALL GUARD)
MOP SINK
AS704
K
L
4'-0"
18 " LOCKER
DEPTH
MOUNTED ON
LEGS
ACCEPTS
PADLOCKS
VENTED
AS704
ENLARGED PLANS AND INTERIOR
ELEVATIONS
1/4" = 1'-0"
ENLARGED KITCHEN / BEDROOM E (TYP) PLAN LEVEL ONE
1/4" = 1'-0"
ENLARGED LOUNGE/ADMIT/LEVEL TWO
1/4" = 1'-0"
ENLARGED ENTRANCE PLAN LEVEL ONE
1/4" = 1'-0"
LOUNGE/ KITCHEN/ PANTRY (WINDOW WALL)
1/4" = 1'-0"
LOUNGE/ KITCHEN/ PANTRY (CORR WALL)
1/4" = 1'-0"
KITCHEN (LOUNGE WALL)
1/4" = 1'-0"
LOUNGE (CASEWORK WALL)
1/4" = 1'-0"
BEDROOM E EL
1/4" = 1'-0"
BEDROOM TYPE E RCP
REFLECTED CEILING PLAN GENERAL NOTES
1. SEE SHEET AS930 FOR CEILING TRANSITION AND SPECIALITY
CEILING EQUIPMENT DETAILS
2. ALIGN CEILING SOFFITS WITH ADJACENT PARTITIONS, TYP.
UNO.
3. COORDINATE SIZE & LOCATION OF CEILING OPENING WITH
EQUIPMENT SUPPLIER.
4. SPRINKLER HEADS SHOWN ON THE RCP'S ARE THOSE OF
DESIGN CONCERN. CENTER ALL SPRINKLER HEADS IN CEILING
GRID. ALL AREAS ARE REQUIRED TO BE SPRINKLERED.
INTERIOR ELEVATION GENERAL NOTES
1. REFER TO AS960 CASEWORK FINISHES AND GENERAL
NOTES FOR CABINET TYPES, TOP TYPES, SHELF TYPES,
PLAM. FINISHES, WOOD FINISHES, ADJUSTABLE SHELVING
AND OTHER GENERAL CASEWORK NOTES AND
INFORMATION.
2. FOR TYPICAL COUNTER TOP TYPES, UNDERCOUNTER
TASK LIGHTING, SUPPORT BRACKET TYPES, COUNTER TOP
CORNER, GROMET, GYB/PLAM SOFFIT DETAILS AND
PLAM/WOOD FINISHES, SEE AS960 AND CASEWORK FINISHES
AND GENERAL NOTES.
3. SEE SPECIFICATION FOR BUILDING, TOILET AND
BATHROOM ACCESSORIES.
4. REFER TO SHEET AS800 FOR TYPICAL FITTINGS,
FIXTURES, ACCESSORIES, ASSEMBLIES TYPICAL MOUNTING
HEIGHTS, DIMENSIONS AND OTHER GENERAL INFORMATION,
UNO. SEE ALSO FURNITURE AND EQUIPMENT PLANS AND
SCHEDULE.
5. PROVIDE WALL BLOCKING AT TV'S, ARTWORK, MBD AND
TBD AND ALL OTHER WALL MOUNTED ITEMS - SEE AS900.
6. RESIDENT ROOM BATHROOMS TO BE PROVIDED WITH:
6A. LAV BASIN WITH MIR MIRROR, SDISP SOAP DISPENSER,
US UTILITY SHELF, PTC PAPER TOWL DISPENSER.
6B. TOILET WITH GB GRAB BARS AND TPH TOILET PAPAER
HOLDER.
6C. SHOWER WITH CCT CUBICLE CURTAIN TRACK, SD SOAP
DISPENSER AND CONTROLS.
6D. SEE PLANS, INT. ELEV. AND/OR TYPICAL MOUNTING
HEIGHT SHEET FOR ARRANGEMENT OF ELEMENTS.
7. RESIDENT ROOM BATHROOMS ACCESSIBLE DESIGNATED
TO BE PROVIDED WITH:
7A. LAV BASIN WITH MIR MIRROR, SDISP SOAP DISPENSER,
PTC PAPER TOWL DISPENSER.
7B. TOILET WITH GB GRAB BARS AND TPH TOILET PAPAER
HOLDER.
7C. SHOWER WITH FSB FOLDING SHOWER BENCH, SD SOAP
DISPENSER, GB GRABE BARS, CCT CUBICLE CURTAIN
TRACKS AND CONTROLS.
7D. SEE PLANS, INT. ELEV. AND/OR TYPICAL MOUNTING
HEIGHT SHEET FOR ARRANGEMENT OF ELEMENTS.
8. TUB ROOMS TO BE PROVIDED WITH:
8A. LAV BASIN WITH MIR MIRROR, SDISP SOAP DISPENSER,
PTC PAPER TOWLE CABINET.
8B. BATH TUBS WITH GB GRAB BARS.
8C. SEE PLANS, INT. ELEV. AND/OR TYPICAL MOUNTING
HEIGHT SHEET FOR ARRANGEMENT OF ELEMENTS.
9. SET SHOWER BASE INTO FLOOR TOPPING TO ACHIEVE
1/4" MAX THRESHOLD TRANSITION.
1/4" = 1'-0"
LAUNDRY EL 1ST & 2ND FLR
NOTE:
GYB CEILING @ 5107
CONC CEILING @ 5252, 5355,5352,5343
1/4" = 1'-0"
HAC EL - 1
1/4" = 1'-0"
HAC EL - 2
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Dwg.
Office of
Construction and Facilities
Management
100% CD NOVEMBER 8, 2017
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h o n e f o o t t h r e e i n c h e s o n e f o o t
FULLY SPRINKLED
of
COMPLETE CONSTRUCTION
1ST & 2ND FLOOR B405
VAS JE/BH07/25/2017
676-18-107
VA MEDICAL CENTER TOMAH, WI
No. Revisions Date
NO SCALE
2.1
STAFF LOUNGE
NO SCALE
STAFF LOUNGE LOCKERS
ACCOMPANING AMENDMENT VA69D-18-B-1687 00005
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it.