Station_346_-_Construction_Documents.pdf

PDF 20 MB Posted

Attached to
CFD Stations Remodel Project
Solicitation number
IFB-2026-012
Issued by
Hamilton County, Indiana

About this file

Construction Documents Summary

This document is a comprehensive set of construction drawings for the Renovation of Station 46 of the Carmel Fire Department, located at 540 W. 136th Street, Carmel, Indiana 46032. The project encompasses architectural, mechanical, electrical, plumbing, fire protection, and technology systems for a two-story fire station with a total building area of 11,390 square feet (5,125 SF on the first floor and 6,265 SF on the second floor). The renovation scope includes creating individual sleeping rooms and associated upgrades on the second floor and installing new decontamination facilities on the first floor. The facility is classified as Business Group B (Fire Station) construction with Type V-B construction type, permitting two stories. The building contains 59 rooms including 11 bedrooms, multiple restrooms, locker rooms, exercise and fitness areas, a decontamination room, apparatus bay, and various support spaces. The drawings indicate the project was issued for construction on August 14, 2026, and include demolition plans for both floors, electrical systems, mechanical and HVAC systems, plumbing infrastructure, fire protection systems, and technology provisions.

The construction documents specify detailed requirements for interior finishes, wall assemblies with acoustic and fire-rated specifications, casework and millwork installations, and various mechanical and electrical systems. All interior walls are designated as S3A-2a construction type unless noted otherwise, with specific wall types identified for acoustic performance ratings ranging from 47 to 56 STC. The project includes provisions for moisture-resistant gypsum wall board in wet areas, solid surface countertops and backsplashes, and various finish materials including carpet tile, sealed concrete, and ceramic tile flooring. The documents reference multiple alternates, including Alternate 1 for upgrading an existing laundry room into a decontamination facility, Alternate 2 for custom solid wood millwork bunk beds, and Alternate 3 for alternative flooring finishes. All work must comply with the 2012 International Building Code with 2014 Indiana amendments and related state and local codes. The general contractor is responsible for coordination with the owner regarding on-site activities, dust control through partitions, material staging, and daily cleanup procedures to maintain safe operations during construction.

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATION 46

VICINITY MAP

CONTRACTOR PARKING

AND STAGING

STAGING MAP

OFF LIMITS

DRAWING INDEX

ARCHITECTURAL

Sheet Number NAME

A001 GENERAL INFORMATION

A002 FIRE & LIFE SAFETY PLANS

AD101 FIRST FLOOR DEMOLITION PLANS

AD102 SECOND FLOOR DEMOLITION PLANS

A100 OVERALL PLANS

A101 FIRST FLOOR PLAN

A102 SECOND FLOOR PLAN

A103 CEILING PLAN - FIRST

A104 CEILING PLAN - SECOND

A401 LARGE SCALE VIEWS

A402 LARGE SCALE VIEWS

A403 LARGE SCALE VIEWS

A501 DETAILS

A600 DOOR & WINDOW SCHEDULES, ELEVATIONS

A601 ROOM FINISH SCHEDULE

ELECTRICAL

Sheet Number NAME

E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS

E101 FIRST FLOOR ELECTRICAL DEMOLITION FLOOR PLAN

E102 SECOND FLOOR ELECTRICAL DEMOLITION FLOOR PLAN

E301 FIRST FLOOR LIGHTING FLOOR PLAN

E302 SECOND FLOOR LIGHTING FLOOR PLAN

E311 FIRST FLOOR POWER AND SYSTEMS FLOOR PLAN

E312 SECOND FLOOR POWER AND SYSTEMS FLOOR PLAN

E501 ELECTRICAL DETAILS

E601 ELECTRICAL SCHEDULES

E701 ELECTRICAL DIAGRAMS

M001 MECHANICAL SYMBOLS AND ABBREVIATIONS

M101 FIRST FLOOR MECHANICAL DEMOLITION PLAN

M111 SECOND FLOOR MECHANICAL DEMOLITION PLAN

M301 FIRST FLOOR MECHANICAL PLAN

M311 SECOND FLOOR MECHANICAL PLAN

M312 SECOND FLOOR PIPING PLAN

M401 FIRST FLOOR ENLARGED PIPING PLAN

M501 MECHANICAL DETAILS

M502 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

M602 MECHANICAL SCHEDULES

ME701 HVAC CONTROLS WIRING, DIAGRAMS, AND SEQUENCES

ME702 HVAC CONTROLS WIRING, DIAGRAMS, AND SEQUENCES

MECHANICAL

Sheet Number NAME

PLUMBING

Sheet Number NAME

P001 PLUMBING SYMBOLS AND ABBREVIATIONS

P100 UNDERSLAB PLUMBING DEMOLITION FLOOR PLAN

P101 FIRST FLOOR PLUMBING DEMOLITION FLOOR PLAN

P111 SECOND FLOOR PLUMBING DEMOLITION FLOOR PLAN

P300 UNDERSLAB PLUMBING FLOOR PLAN

P301 FIRST FLOOR PLUMBING FLOOR PLAN

P311 SECOND FLOOR PLUMBING FLOOR PLAN

P501 PLUMBING DETAILS

P601 PLUMBING SCHEDULES

P701 PLUMBING DIAGRAMS

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica

Group, Inc. It is intended solely for use by The Etica

Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica

Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTIONMechanical, Electrical, Plumbing Engineer:

Architect, Civil Engineer:

Etica Group, Inc.

8720 Castle Creek Parkway East Drive, Suite 400

Indianapolis, IN 46250

(317) 466-9520 www.eticagroup.com

Technology Engineer:

/1

/2

:5

:5

A

M A u to d e s k D o c s

/2

C a rm e l F ir e

S ta tio n

/2

C a rm e l F ir e

S ta tio n

.r vt

G001

250060

ERS TLG

COVER

R e n o va tio n o f S ta tio n

W th S t.

C a rm e l, IN

C ity o f

C a rm e l

O n e C iv ic

S q u a re

C a rm e

8/14/2026

Renovation of Station 46

8/14/2026

540 W. 136th St. Carmel, IN 46032

City of Carmel

ISSUED FOR CONSTRUCTION

FIRE PROTECTION

Sheet Number NAME

FP001 FIRE PROTECTION SYMBOLS AND ABBREVIATIONS

FP101 FIRST FLOOR FIRE PROTECTION DEMOLITION

FP111 SECOND FLOOR FIRE PROTECTION DEMOLITION

FP301 FIRST FLOOR FIRE PROTECTION FLOOR PLAN

FP311 SECOND FLOOR FIRE PROTECTION FLOOR PLAN

TECHNOLOGY

Sheet Number NAME

T000 SYMBOLS AND ABBREVIATIONS

TD101 TECHNOLOGY FIRST FLOOR DEMOLITION

TD102 TECHNOLOGY SECOND FLOOR DEMOLITION

T101 TECHNOLOGY FIRST FLOOR PLAN

T102 TECHNOLOGY SECOND FLOOR PLAN

T501 TECHNOLOGY DETAILS

T502 TECHNOLOGY DETAILS

REVISION SCHEDULE

# DESCRIPTION DRAWN BY DATE ISSUED

LOCUTION SYSTEM

Sheet Number NAME

---- LOCUTION SYSTEM DESIGN BY ERS FOR REFERENCE ONLY

UP

• 2012 INTERNATIONAL BUILDING CODE W/ 2014 INDIANA AMENDMENTS

• 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007)

• 2006 INTERNATIONAL PLUMBING CODE W/ 2012 INDIANA AMENDMENTS

• 2008 NATIONAL ELECTRIC CODE W/ 2009 INDIANA AMENDMENTS

• 2012 INTERNATIONAL MECHANICAL CODE W/ 2014 INDIANA AMENDMENTS

• 2012 INTERNATIONAL FIRE CODE W/ 2014 INDIANA AMENDMENTS

PROJECT LOCATION:

540 W. 136th ST.

CARMEL, IN 46032

PROJECT SCOPE:

CARMEL FIRE DEPARTMENT STATION 46 IS BEING RENOVATED TO PROVIDE INDIVIDUAL SLEEPING ROOMS AND ASSOCIATED UPGRADES ON THE SECOND FLOOR AND NEW DECONTAMINATION FACILITIES ON THE FIRST FLOOR.

OCCUPANCY CLASSIFICATION:

BUSINESS GROUP B - FIRE STATION (SECTION 304.1)

CONSTRUCTION TYPE:

TYPE V-B (SECTION 602.5)

ALLOWABLE AREA (PER STORY): (SECTION 506.1)

TABULAR AREA: 9,000 SF (TABLE 503)

FRONTAGE INCREASE: 6,750 SF (SECTION 506.2)

SPRINKLER INCREASE: 18,000 SF (SECTION 506.3)

TOTAL ALLOWABLE: 33,750 SF

TOTAL BUILDING SF: 11,390 SF 1ST FLOOR

5,125 SF 2ND FLOOR & MEZZANINE

16,515 SF TOTAL

ALLOWABLE HEIGHT AND STORIES:

TWO-STORIES PERMITTED FOR BUILDINGS OF GROUP B OCCUPANCY AND TYPE V-B CONSTRUCTION. FACILITY IS TWO-

STORY.

BUILDING ELEMENTS, FIRE RESISTIVE REQUIREMENTS (SECTION 602.5)

STRUCTURAL FRAME 0 HRS(TABLE 601 & 602)

BEARING WALLS

EXTERIOR 0 HRS

INTERIOR 0 HRS

NONBEARING WALLS / PARTITIONS EXTERIOR 0 HRS

NONBEARING WALLS / PARTITIONS INTERIOR 0 HRS

FLOOR CONSTRUCTION 0 HRS

ROOF CONSTRUCTION 0 HRS

FIRE WALLS:

A FIRE WALL IS NOT REQUIRED SINCE THE ACTUAL AREA IS LESS THAN THE ALLOWABLE AREA.

FIRE BARRIERS:

STAIRWAYS ARE NOT REQUIRED TO BE ENCLOSED (SECTION 1009.3 EXCEPTION 4)

FIRE PARTITIONS:

NONE REQUIRED.

NON-RELATED INCIDENTAL USE SEPERATION: NOT REQUIRED (TABLE 509)

CORRIDORS: 0-HR (TABLE 1012.1)

DEADEND CORRIDOR: 50' MAX (1018.4 EXCEPTION 2)

COMMON PATH OF EGRESS: 100' MAX (TABLE 1014.3)

EXIT ACCESS TRAVEL DISTANCE: 300' MAX

AUTOMATIC SPRINKLER REQUIREMENTS:

THE EXISTING BUILDING IS SPRINKLERED.

AREA OF REFUGE

AREA OF REFUGE IS NOT REQUIRED (SECTION 1007.3 EXCEPTION 2)

PLUMBING FIXTURE COUNT

159 MEN (75%)

5 WC REQUIRED / 4 WC & 3 URINALS PROVIDED

3 LAVS REQUIRED / 4 LAVS PROVIDED

53 WOMEN (25%)

3 WC / 4 WC PROVIDED (INCLUDING UNISEX RR)

2 LAVS / 4 LAVS PROVIDED (INCLUDING UNISEX RR)

3 DF REQUIRED / 2 DF PROVIDED PLUS ACCESS TO DRINKING WATER IN KITCHEN

1 SS REQUIRED / 1 SS PROVIDED

VESTIBULE

ENTRY

CORRIDOR

PANTRY

PANTRY

PANTRY

KITCHEN

DINING ROOM

DAY ROOM

WATCH ALCOVE

TOILET

TOILET

CAPTAIN OFFICE

CORRIDOR

WATCH ROOM

STORAGE

EXERCISE

CLOSET

T'COM. CLOSET

MECHANICAL/ELECTRICAL

STAIR

STAGING

STAIR

FITNESS

FIRE POLE

125b

DECONTAMINATION

APPARATUS BAY

GEAR STORAGE

MAINTENANCE ROOM

GEAR STORAGE

132STORAGE

EMS STORAGE

NO NEW WORK

99' EXIT PATH

FEC

32' - 6": COMMON

PATH OF TRAVEL

STORAGE

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

STORAGE

UNISEX RR

MOTHER'S ROOM

QUIET ROOM

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

WOMEN'S LOCKERS

WOMEN'S RR

WOMEN'S SHOWER

MEN'S RR

MEN'S SHOWER

JANITOR'S

BEDROOM

BEDROOM

BEDROOM

NO NEW WORK

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

A002

250060

ERS TLG

FIRE & LIFE

SAFETY PLANS

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

CODE SUMMARY

A002 3/32" = 1'-0" REF:3/A403

FIRST FLOOR PLAN 1

A. FIRE EXTINGUISHERS: EXISTING FIRE EXTINGUISHER CABINETS AND EXTINGUISHERS

ARE TO REMAIN IN EXISTING LOCATIONS

LIFE SAFETY NOTES

A002 3/32" = 1'-0" REF:2/A401

SECOND FLOOR PLAN 2

Room Schedule Name Number Area Occupancy Occupant Level

LEVEL 1

VESTIBULE 101 87 SF 100 1 LEVEL 1

ENTRY 102 194 SF 100 1 LEVEL 1

CORRIDOR 103 64 SF 100 1 LEVEL 1

PANTRY 104 65 SF 300 1 LEVEL 1

PANTRY 105 56 SF 300 1 LEVEL 1

PANTRY 106 59 SF 300 1 LEVEL 1

KITCHEN 107 434 SF 15 28 LEVEL 1

DINING ROOM 108 310 SF 15 20 LEVEL 1

DAY ROOM 109 649 SF 15 43 LEVEL 1

WATCH ALCOVE 110 64 SF 100 1 LEVEL 1

TOILET 111 57 SF 100 1 LEVEL 1

TOILET 112 57 SF 100 1 LEVEL 1

DECONTAMINATION 113 125 SF 100 1 LEVEL 1

CAPTAIN OFFICE 114 142 SF 100 1 LEVEL 1

FITNESS 115 330 SF 50 6 LEVEL 1

CORRIDOR 116 37 SF 100 1 LEVEL 1

WATCH ROOM 117 473 SF 100 4 LEVEL 1

STORAGE 118 42 SF 100 1 LEVEL 1

EXERCISE 119 568 SF 50 11 LEVEL 1

CLOSET 120 29 SF 300 1 LEVEL 1

T'COM. CLOSET 121 51 SF 300 1 LEVEL 1

MECHANICAL/ELECT

RICAL

122 246 SF 300 1 LEVEL 1

STAIR 124 177 SF LEVEL 1

STAGING 125 657 SF 300 2 LEVEL 1

FIRE POLE 125b 31 SF 100 1 LEVEL 1

STAIR 126 176 SF LEVEL 1

APPARATUS BAY 127 3509 SF 300 11 LEVEL 1

GEAR STORAGE 128 283 SF 300 1 LEVEL 1

MAINTENANCE ROOM 129 225 SF 300 1 LEVEL 1

EMS STORAGE 130 64 SF 300 1 LEVEL 1

STORAGE 131 152 SF 300 1 LEVEL 1

GEAR STORAGE 132 284 SF 300 1 LEVEL 1

N

Room Schedule Name Number Area Occupancy Occupant Level

LEVEL 2

BEDROOM 001 94 SF 200 1 LEVEL 2

BEDROOM 002 94 SF 200 1 LEVEL 2

BEDROOM 003 124 SF 200 1 LEVEL 2

BEDROOM 004 98 SF 200 1 LEVEL 2

BEDROOM 005 94 SF 200 1 LEVEL 2

BEDROOM 006 94 SF 200 1 LEVEL 2

BEDROOM 007 94 SF 200 1 LEVEL 2

BEDROOM 008 98 SF 200 1 LEVEL 2

BEDROOM 009 124 SF 200 1 LEVEL 2

BEDROOM 010 94 SF 200 1 LEVEL 2

BEDROOM 011 94 SF 200 1 LEVEL 2

STORAGE 027 13 SF 300 1 LEVEL 2

UNISEX RR 028 73 SF 100 1 LEVEL 2

MOTHER'S ROOM 029 49 SF 100 1 LEVEL 2

QUIET ROOM 030 330 SF 15 19 LEVEL 2

MECHANICAL 031 81 SF 300 1 LEVEL 2

VESTIBULE 032 46 SF 100 1 LEVEL 2

CORRIDOR 033 474 SF 100 5 LEVEL 2

VESTIBULE 034 43 SF 100 1 LEVEL 2

WOMEN'S LOCKERS 035 172 SF 100 1 LEVEL 2

WOMEN'S RR 036 52 SF 100 1 LEVEL 2

WOMEN'S SHOWER 037 63 SF 100 1 LEVEL 2

MEN'S RR 038 160 SF 100 1 LEVEL 2

MEN'S SHOWER 039 108 SF 100 1 LEVEL 2

MEN'S LOCKERS 040 467 SF LEVEL 2

JANITOR'S 041 39 SF 300 1 LEVEL 2

STORAGE 217 868 SF 300 3 LEVEL 2

Grand total: 59 13840 SF

N

REVISION SCHEDULE

# DESCRIPTION DRAWN BY DATE ISSUED

CONCRETE

REGION TYPES TAGS

MATERIAL TAG

W12A WALL TAG

AREA NAME

AREA TAG

CEIL-1 CEILING TAG

XXX DOOR TAG

SYMBOLS

ROOM TAG

1t WINDOW TAG

SPOT ELEVATION

A101

Ref

A101

Ref

A101

Ref

R1 REVISION TAG

N

Name Elevation

SECTION HEAD OPEN

SECTION HEAD NO ARROW

SECTION HEAD FILLED

NORTH ARROW

LEVEL HEAD

0 GRID HEAD

A101

ELEVATION MARK BODY EXTERIOR

CENTERLINE

A101

A

A101

A

ELEVATION MARK BODY INTERIOR

1 PLAN NOTE

OTHER SYMBOLS

XX MULTI-CATEGORY TAG

(TYPE MARK)

VIEW NAME

A199.9 1/8" = 1'-0"?

REF:R/R101

VIEW TITLE

32"X

99 20"

ACTUAL LOAD

EGRESS CAPACITY

REQUIRED EGRESS

WIDTH

ACTUAL EGRESS

WIDTH

EGRESS TAG

ROOM NAME

ROOM NUMBER

LIFE SAFETY TAG

ROOM FINISH TAG

150 SF

Name

ROOM NAME

WL-1BS-1

FLOR-1

ROOM NUMBER

ROOM AREA

OCCUPANT LOAD

ROOM NUMBER

FLOOR FINISH

WALL FINISH

BASE FINISH

EARTH

GRANULAR FILL

BRICK

WOOD

WOOD BLOCKING / HEAVY TIMBER

CONCRETE BLOCK

PLYWOOD

SAND, GYPSUM, OR AS NOTED

STEEL / METAL

RIGID INSULATION

BATT INSULATION

SOLID SURFACE / PLASTIC

MORTAR

ALUMINUM

ROOM PRESENTATION

TAG

NAME

REPLACED

ABD

AC

A/E

AFF

AHU

ALT

ALUM

ASPH

BOT

BD

BFLG

BIT

BJT

BLDG

BLK

BRG

BS

BUR

BRK

C/C

CJ

CLG

CLR

CMU

CNTR

CO

COL

COORD

CONC

CONT

CONTR

DBL

DEG

DEMO

DEPT

DIA

DIM

DL

DN

DR

DS

DTL

DWG

EF

EPDM

EIFS

EJ

ELEC

ELEV

ENG

EP

ETC

EST

EXG

EXP

EXT

ABANDONED

AIR CONDITIONING

ASPHALT EMULSION

ABOVE FINISH FLOOR

AIR HANDLING UNIT

ALTERNATE

ALUMINUM

ASPHALT

BOTTOM

BOARD

BASE FLASHING

BITUMINOUS

BED JOINT

BUILDING

BLOCK

BEARING

BOTH SIDES

BUILT UP ROOFING

BRICK

CENTER TO CENTER

CONTROL JOINT

CEILING

CLEAR

CONCRETE MASONRY UNIT

COUNTER FLASHING

CLEAN OUT

COLUMN

COORDINATE

CONCRETE

CONTINUOUS or CONTINUED

CONTRACTOR

DOUBLE

DEGREE

DEMOLITION

DEPARTMENT

DIAMETER

DIMENSION

DEAD LOAD

DOWN

DOOR

DOWN SPOUT

DETAIL

DRAWING

EXHAUST FAN

ETHYLENE PROPYLENE DIENE MONOMER

EXTERIOR INSULATION FINISH SYSTEM

EXPANSION JOINT

ELECTRICAL

ELEVATION or ELEVATOR

ENGINEER

ELECTRICAL PANEL

ETCETERA

ESTIMATE

EXISTING

EXPOSED

EXTERIOR

FB

FD

FIN

FLG

FSR

FLR

FP

FT

GA

GALV

GB

GC

GL

GR

GRV

GWB

GYP

HGT

HDWD

HDWR

HM

HORZ

HVAC

IN

INFO

INSUL

JT

LAM

LBS

LFT

LVR

LWC

MAS

MATL

MAX

MBR

MECH

MFR

MH

MIN

MISC

MO

MRD

MTD

MTD

MTG

MTL

N

NA

NIC

NO

NOM

NTS

FACE BRICK

FLOOR DRAIN

FINISHED

FLASHING

FLEXIBLE SHEET ROOFING

FLOOR

FALL PROTECTION

FOOT or FEET

GAUGE

GALVANIZED

GLASS BLOCK

GENERAL CONTRACTOR

GLASS

GRADE

GRAVITY ROOF VENT

GYPSUM WALL BOARD

GYPSUM

HEIGHT

HARDWOOD

HARDWARE

HOLLOW METAL

HORIZONTAL

HEATING, VENTILATING,

AIR CONDITIONING

INCH

INFORMATION

INSULATION

JOINT

LAMINATED

POUNDS

LINEAR FOOT

LOUVER

LIGHT WEIGHT CONCRETE

MASONRY

MATERIAL

MAXIMUM

MODIFIED BITUMEN ROOFING

MECHANICAL

MANUFACTURER

MAN HOLE

MINIMUM

MISCELLANEOUS

MASONRY OPENING

METAL ROOF DECK

MOUNTED

MOUNTED

MOUNTING

METAL

NORTH

NOT APPLICABLE

NOT IN CONTRACT

NUMBER

NOMINAL

NOT TO SCALE

OA

OC

OH

OPNG

PT

PCC

PERP

PL

PLAS

PLBG

PWD

PREFAB

PROJ

PSI

PP

PS

PV

PVC

QTY

RC

RD

RE

REINF

REQ'D

RFG

RS

RV

REV

SATT

SC

SD

SECT

SHT

SIM

SPECS

SS

STD

STL

T&G

TEMP

TERM

THK

TOM

TOS

TO

TYP

UNO

UNF

UTIL

VB

VCT

VR

VERT

VIF

OVERALL

ON CENTER

OVERHEAD

OPENING

PAINT

PRE-CAST CONCRETE

PERPENDICULAR

PLATE

PLASTIC

PLUMBING

PLYWOOD

PREFABRICATED

PROJECT

POUNDS PER SQUARE INCH

PIPE PENETRATION

PIPE SEAL

PLUMBING VENT

POLY VINYL CHLORIDE

QUANTITY

ROOF CORE

ROOF DRAIN

REFER TO

REINFORCING

REQUIRED

ROOFING

ROOF SUMP

RELIEF VENT

REVISION

SATELLITE DISH

SCUPPER

STORM DRAIN

SECTION

SHEET

SIMILAR

SPECIFICATIONS

STAINLESS STEEL

STANDARD

STEEL

TONGUE & GROOVE

TEMPERATURE

TERMINATION

THICK or THICKNESS

TOP OF MASONRY

TOP OF STEEL

TOP OF

TYPICAL

UNLESS NOTED OTHERWISE

UNFINISHED

UTILITY

VINYL BASE

VINYL COMPOSITION TILE

VAPOR RETARDER

VERTICAL

VERIFY IN FIELD

WHERE SOUND BATTS ARE INDICATED PROVIDE

CONTINUOUS ACOUSTICAL SEALANT, BOTH SIDES

CONTINUOUS BOTTOM TRACK ATTACH TO

STRUCTURE @ 24" O.C. MAX.

5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED

FIBERGLASS SOUND BATTS, WHERE INDICATED,

FULL DEPTH OF CAVITY

LINE OF CEILING

TOP TRACK, ATTACH TO STUDS W/ WAFERHEAD SCREWS HOLD

TOP TRACK, VERTICAL STUDS & GWB DOWN FROM STRUCTURE

1.5" (OR 1.25 X ANTICIPATED LIVE LOAD DEFLECTION) TO

ALLOW FOR DEFLECTION OF STRUCTURE, TYP.

CONTINUOUS DEEP LEG TRACK (2 1/2" FLANGES) ATTACH

TO STRUCTURE ABOVE @ 16" O.C. DO NOT SECURELY

FASTEN TO TOP TRACK, VERTICAL STUDS OR GWB, TYP.

WHERE SOUND BATTS INDICATED PROVIDE

ACCOUSTICAL SEALANT ALL EDGES (BOTH SIDES), TYP.

LINE OF DECK OR STRUCTURE ABOVE

FIRE SAFING, BOTH SIDES AT RATED WALLS, TYP.

WALL BASE PER FINISH SCHEDULE

LINE OF STRUCTURE BELOW

METAL STUDS - 25 GA MIN., FOR SOUND CONTROL

WHERE SOUND BATTS ARE INDICATED PROVIDE

CONTINUOUS ACOUSTICAL SEALANT, BOTH SIDES

CONTINUOUS BOTTOM TRACK ATTACH TO

STRUCTURE @ 2' O.C. MAX.

5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED

METAL STUDS - 25 GA MIN., FOR SOUND CONTROL

FIBERGLASS SOUND BATTS,

WHERE INDICATED (FULL DEPTH OF CAVITY)

LINE OF CEILING

(4) SCREWS

METAL STUD BRACE CONT. TO STRUCTURE @ 4' 0" O.C.

MAX. (UNLESS NOTED OTHERWISE) EITHER SIDE OF WALL

TO CLEAR OTHER CONSTRUCTION ITEMS, SIZE TO MATCH

WALL STUDS, TYP. MAX. SLOPE NOT TO EXCEED 1:1

(4) POWDER DRIVEN FASTENERS W/

GALV. WASHERS

LINE OF STRUCTURE ABOVE

WALL BASE PER FINISH SCHEDULE

6"

LINE OF STRUCTURE BELOW

CONTINUOUS BOTTOM TRACK ATTACH TO

STRUCTURE @ 2' O.C. MAX.

5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED

SOLID SURFACE TOP

AT LOCATIONS WITH HANDRAILS OR COUNTERS,

PROVIDE MOMENT CLIP AT EA. STUD, FASTEN TO STUDS

WITH (6) SCREWS, SECURELY FASTEN TO FLOOR.

REFER TO STRUCTURAL NOTES

WALL BASE PER FINISH SCHEDULE

LINE OF STRUCTURE BELOW

WOOD BLOCKING FOR TOP OR RAILING

METAL STUDS - 25 GA MIN., FOR SOUND CONTROL

WHERE SOUND BATTS ARE INDICATED PROVIDE

CONTINUOUS ACOUSTICAL SEALANT, BOTH SIDES

CONTINUOUS BOTTOM TRACK ATTACH TO

STRUCTURE @ 24" O.C. MAX.

5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED

FIBERGLASS SOUND BATTS, WHERE INDICATED, FULL DEPTH OF CAVITY

LINE OF CEILING

TOP TRACK, ATTACH TO STUDS W/ WAFERHEAD SCREWS HOLD

TOP TRACK, VERTICAL STUDS & GWB DOWN FROM STRUCTURE

1.5" (OR 1.25 X ANTICIPATED LIVE LOAD DEFLECTION) TO

ALLOW FOR DEFLECTION OF STRUCTURE, TYP.

WHERE SOUND BATTS INDICATED PROVIDE

ACCOUSTICAL SEALANT ALL EDGES (BOTH SIDES), TYP.

WALL BASE PER FINISH SCHEDULE

LINE OF STRUCTURE BELOW

METAL STUDS - 25 GA MIN., FOR SOUND CONTROL

PARTITION DESIGNATION

FRAMING / CORE MATERIAL

HEIGHT CODE

PERFORMANCE REQUIREMENT

FINISH CONDITION

W6A - 2a

NOMINAL CORE SIZE

FRAMING/CORE MATERIAL

HEIGHT CODE PERFORMANCE REQUIREMENT

FINISH CONDITION

A – 1 LAYER GYP EACH SIDE

B – GYP ON ONE SIDE

C – 2 LAYERS GYP EACH SIDE

D – BACK TO BACK WET WALL

E – SINGLE LOAD WET WALL

F – SEE REMARKS

G – SEE REMARKS

H – SEE REMARKS

1 – 6” ABOVE CEILING

2 – TO DECK

3 – T0 CEILING

4 – AS INDICATED

5 – SEE NOTES

a – ACOUSTIC ASSEMBLY b – PENETRATION RESISTANT c – SHAFT WALL d – DAMAGE RESISTANT e – EPOXY COATED f – FIRE RATED g – FOIL FACED GYPSUM h – SEE REMARKS

C – CAST IN PLACE

E – ENGINEERED

METAL BUILDING

G – GLASS WALL

M – MASONRY

P – PRE-CAST

S – STEEL

W – WOOD

* 3'-6"

* 8"

WALL DEVICE, TYP. WALL DEVICE, TYP.

NOTE:

ALL WALL DEVICES TO BE

CENTER ALIGNED ON SAME SIDE

OF STUD (INCLUDING BUT NOT

LIMITED TO: ELECTRICAL,

MECHANICAL, FIRE PROTECTION,

AND LOW VOLTAGE ITEMS)

*MOVE DEVICE TO ALIGN WHEN DEVICES

ARE WITHIN DISTANCE INDICATED

ABOVE, UNLESS NOTED OTHERWISE

*MOVE DEVICE TO ALIGN WHEN

DEVICES ARE WITHIN 24" OF A

DOOR, UNLESS NOTED OTHERWISE

WALL TYPE NOTES

1. WALL TYPES DO NOT INCLUDE WALL FINISHES. SEE

ROOM FINISH SCHEDULE FOR FINISH INFORMATION.

2. COORDINATE RATING REQUIREMENTS INDICATED

ON SPECIFIC PARTITIONS WITH LIFE SAFETY PLAN.

3. ALL ACCOUSTIC AND FIRE RATED WALLS ARE TO

BE CONSTRUCTED IN ACCORDANCE WITH TESTING

AGENCY REQUIREMENTS. REFER TO SPECIFIC TEST

REPORTS FOR REQUIRED COMPONENTS AND

ASSEMBLY. SEE WALL TYPE REFERENCES AND LIFE

SAFETY SHEETS FOR RATED WALL LOCATIONS.

PROVIDE STOPPING PER MANUFACTURE’S

RECOMMENDATIONS FOR PENETRATIONS THROUGH

RATED WALLS.

4. ALL INTERIOR WALLS WHERE SOUND BATT

INSULATION IS INDICATED ARE CONSIDRED

ACOUSTIC WALLS. WHERE SPECIFIC STC RATINGS

ARE REQUIRED SEE INDIVIDUAL WALL TYPE

PARTITIONS.

5. AT STUD WALLS WHICH DO NOT EXTEND TO

STRUCTURE, PROVIDE BRACING 4'-0" O.C. AND AT

CENTERLINE OF DOOR OPENINGS.

6. PROVIDE WOOD BLOCKING AT TOP AND BOTTOM

OF CABINETS. COORDINATE HEIGHTS WITH

CASEWORK ELEVATIONS.

7. AT STUD WALLS, WOOD BLOCKING IS REQUIRED

AT ALL WALL MOUNTED ITEMS INCLUDING BUT NOT

LIMITED TO THE FOLLOWING LOCATIONS:

A. WALL MOUNTED COUNTERS AND COUNTERTOP

SUPPORTS.

B. WALL MOUNTED ACCESSORIES AND

EQUIPMENT

C. WALL MOUNTED DOORSTOPS

D. WALL MOUNTED DOOR HOLD OPEN DEVICES

AND/OR CLOSERS

E. TOILET ROOM PARTITIONS AND ACCESSORIES

F. WALL MOUNTED TV’S AND BRACKETS

G. OTHER LOCATIONS AS REQUIRED BY THE

ARCHITECT AND INDUSTRY STANDARDS.

8. INSTALL BLOCKING BETWEEN EXISTING

STRUCTURAL MEMBERS TO ALLOW PROPER

ATTACHMENT OF NEW PARTITIONS TO STURCTURE

ABOVE.

TYPE

PARTITION

WIDTH

CORE

SIZE

MAX. STUD

SPACING

O.C.

ACCOUSTIC

RATING

FIRE

RATING

UL

NUMBER

REMARKS

S3A 4 7/8" 3 5/8" 24" O.C. 47 STC 1 HR U465

S3B 4 1/4" 3 5/8" 24" O.C. --- --- ---

S3C 6 1/8" 3 5/8" 24" O.C. 56 STC 2 HR U411

S3D 3 5/8" 24" O.C. 47 STC 1 HR U465

MOISTURE

RESISTANT

GWB

S3E

3 5/8" 24" O.C. 47 STC 1 HR U465

MOISTURE

RESISTANT

GWB

S6A 6 7/8" 5 5/8" 24" O.C. 49 STC 1 HR U465

4 7/8"

4 7/8"

S3F 4 1/4" 3 5/8" 24" O.C. --- --- ---

MOISTURE

RESISTANT

GWB

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

A001

250060

ERS TLG

GENERAL

INFORMATION

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

ABBREVIATIONS

N. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT

TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS

AND EQUIPMENT.

M. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO ETICA GROUP, INC. FOR

APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE

FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A

SPECIFIC MANUFACTURER OR MODEL NUMBER.

L. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED

BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF

THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING

MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS

INDICATED ON THE CEILING PLAN).

K. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF

DAILY OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS

SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6 MIL VAPOR

BARRIER ON EACH SIDE.

J. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER, AN AREA FOR STAGING

OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION

AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE

APPROVED BY THE OWNER. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY

CONSTRUCTION CREWS.

I. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE OWNER CLEANUP PROCEDURES

AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN

A SAFE AND CLEAN ENVIRONMENT.

H. ETICA GROUP, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL

NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,

SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR

MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.

G. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT

PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH

APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT

TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.

F. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL

COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER

AND ETICA GROUP WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR

TO MEET THE PROJECT SCHEDULE. NEITHER THE OWNER NOR ARCHITECT IS RESPONSIBLE

FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL

LEAD TIMES.

E. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL

ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS

STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,

AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR

SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS

NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.

D. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY

DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO ETICA GROUP, INC.

C. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR

BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING

RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE

PRECEDENCE.

B. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS

CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK

REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK

SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE

OF WORK.

A. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL

BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT

APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.

GENERAL PROJECT NOTES

A001 1/2" = 1'-0"

STEEL STUD WALL FULL HEIGHT 1

A001 1/2" = 1'-0"

STEEL STUD WALL PARTIAL HEIGHT 2

A001 1/2" = 1'-0"

STEEL STUD WALL AS INDICATED 4

A001 1/2" = 1'-0"

STEEL STUD WALL TO CEILING 5

A001 3/8" = 1'-0"

DEVICE LOCATION DIAGRAM 7

EXISTING ITEM TO REMAIN

EXISTING WALL TO REMAIN

EXISTING DOOR & FRAME TO REMAIN

EXISTING WALL TO BE REMOVED

EXISTING MASONRY WALL TO BE REMOVED

EXISTING CONCRETE WALL TO BE REMOVED

EXISTING DOOR AND FRAME TO BE REMOVED

EXISTING GLAZING TO BE REMOVED

PLAN NOTE DESIGNATION

DEMOLITION LEGEND

VESTIBULE

ENTRY

CORRIDOR

PANTRY

PANTRY

PANTRY

KITCHEN

DINING ROOM

DAY ROOM

WATCH ALCOVE

TOILET

TOILET

CAPTAIN OFFICE

CORRIDOR

WATCH ROOM

STORAGE

EXERCISE

CLOSET

T'COM. CLOSET

MECHANICAL/ELECTRICAL

STAIR

STAGING

STAIR

AD101

FITNESS

EXISTING BULKHEAD

AD101

NOTE: ALTERNATE 1 - UPGRADE EXISTING FIRST

FLOOR LAUNDRY INTO NEW DECONTAMINATION

ROOM AS INDICATED ON SHEET A403, IF ALTERNATE

1 IS NOT ACCEPTED, PROVIDE NEW DOOR ASSEMBLY

AS CALLED OUT IN DOOR SCHEDULE IN NEW

PARTITION AT BASE OF FIRE POLE.

LAUNDRY

LAUNDRY

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica

Group, Inc. It is intended solely for use by The Etica

Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica

Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

/2

/2

:2 :1

P

M A u to d e s k D o c s

/2

C a rm e l F ir e

S ta tio n

/2

C a rm e l F ir e

S ta tio n

.r vt

AD101

250060

ERS TLG

FIRST FLOOR

DEMOLITION

PLANS

R e n o va tio n o f S ta tio n

W th S t.

C a rm e

C ity o f

C a rm e l

O n e C iv ic

S q u a re

C a rm e

8/14/2026

KEY NOTES - DEMOLITION

NO. DESCRIPTION

1. REMOVE EXISTING DOOR ASSEMBLY IN ITS ENTIRETY INCLUDING FRAME AND HARDWARE AND STORE

FOR REUSE

2. REMOVE EXISTING PARTITION IN ITS ENTIRETY

3. EXPAND EXISTING GWB WRAPPED OPENING TO CLOSET WALL. REFRAME HEADER FOR LARGER OPENING.

HEAD HEIGHT TO REMAIN THE SAME.

4. DEMOLISH EXISTING CASEWORK AND LOW PARTITIONS.

5. REMOVE EXISTING LOCKERS.

6. REMOVE EXISTING BENCH

7. DEMOLISH EXISTING COUNTERTOP, SINKS, CABINET, AND MIRROR

8. REMOVE EXISTING FLOOR FINISH. PREP SURFACE FOR NEW FLOOR FINISH

9. NOT USED

10. EXPAND EXISTING DOOR FRAMING TO ACCOMODATE LARGER DOOR, SEE DOOR SCHEDULE

11. REMOVE EXISTING DOOR ASSEMBLY IN IT'S ENTIRETY

12. CUT SLAB TO TIE NEW TRENCH DRAIN INTO EXISTING FLOOR DRAIN SYSTEM, SEE PLUMING DRAWINGS

13. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL ON ONE SIDE AS INDICATED BY DASHED LINE

14. REMOVE EXISTING WALL CABINETS AND SALVAGE FOR RE-USE

15. REMOVE EXISTING BASE CABINETS AND COUNTERTOP

16. REMOVE EXISTING PLUMBING FIXTURE

17. REMOVE EXISTING WASHER AND DRYER - COORDINATE WITH OWNER

18. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL AS INDICATED BY DASHED LINE

19. REMOVE EXISTING GWB ON UNISEX RESTROOM SIDE OF WALL AS INDICATED BY DASHED LINE

20. REMOVE EXISTING DOOR AND HARDWARE. FRAME CAN REMAIN IN PLACE. PREP EXISTING FRAME FOR

NEW DOOR AND HARDWARE.

G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS

AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO

COMMENCMENT OF WORK.

F. THE CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY

THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED. ANY

QUESTIONS SHALL PROMPTLY REFERRED TO THE ARCHITECT FOR RESOLUTION.

E. CONTRACTOR IS RESPONSIBLE FOR CUTTING AND PATCHING OF FLOORS, WALLS, AND

CEILINGS. PATCH ALL AREAS REQUIRE TO ACCEPT NEW HVAC, PLUMBING, AND

ELECTRICAL WORK. PATCH AND REPAIR TO A FINISHED CONDITION INDICATED IN THE

DRAWINGS OR TO MATCH EXISTING.

D. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING

SURFACES, MATERIALS, AND COMPONENTS TO REMAIN. ANY DAMAGE RESULTING

FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED BY THE CONRACTOR T...

C. WHERE DEMOLITION WORK EXPOSED AND UNFINISHED SURFACE OR CONDITION IN A

SURFACE TO REMAIN EXPOSED, THE CONTRACTOR SHALL PATCH, REPAIR, AND

PREPARE SUCH SURFACE OR CONDITION AS REQUIRED TO PROPERLY RECEIVE NEW

FINISHES AND TO MATCH THE EXISTING ADJACENT SURFACE.

B. ALL EXISTING SURFACE LOCATED ADJACENT TO DEMOLITION WORK AND SCHEDULE

TO REMAIN EXPOSED AFTER COMPLETION OF NEW CONSTRUCTION SHALL BE

REPAIRED AND PATCHED AS REQUIRED TO MATCH EXISTING.

A. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION WORK

AND SCHEDULED TO RECEIVE NEW CONSTRUCTION, SHALL BE REPAIRED AND

PATCHED AS REQUIRED TO CLEANLY AND SOUNDLY RECEIVE NEW WORK.

GENERAL DEMOLITION PLAN NOTES

AD101 1/8" = 1'-0" REF:3/A403

FIRST FLOOR DEMOLITION PLAN 1

AD101 1/8" = 1'-0" REF:3/A403

FIRST FLOOR RCP DEMOLITION 2

KEY NOTES - RCP DEMOLITION

NO. DESCRIPTION

1. REMOVE EXISTING CEILING AND FIXTURES AND PREP FOR NEW WORK. SALVAGE EXISTING CEILING TILES

FOR POSSIBLE REUSE. COORDINATE WITH OWNER

3. RECONFIGURE EXISTING BULKHEAD TO ACCOMODATE NEW WORK

AD101 1/2" = 1'-0" REF:1/AD101

FIRST FLOOR DEMOLITION PLAN - DECONTAMINATION 3

AD101 1/2" = 1'-0" REF:2/AD101

RCP DEMOLITION - DECONTAMINATION 4

DN DN

EXISTING ITEM TO REMAIN

EXISTING WALL TO REMAIN

EXISTING DOOR & FRAME TO REMAIN

EXISTING WALL TO BE REMOVED

EXISTING MASONRY WALL TO BE REMOVED

EXISTING CONCRETE WALL TO BE REMOVED

EXISTING DOOR AND FRAME TO BE REMOVED

EXISTING GLAZING TO BE REMOVED

PLAN NOTE DESIGNATION

DEMOLITION LEGEND

88 88

4 4

1 1

AD102 1/8" = 1'-0" REF:2/A401

SECOND FLOOR DEMOLITION 2

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

AD102

250060

ERS TLG

SECOND FLOOR

DEMOLITION

PLANS

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

KEY NOTES - DEMOLITION

NO. DESCRIPTION

1. REMOVE EXISTING DOOR ASSEMBLY IN ITS ENTIRETY INCLUDING FRAME AND HARDWARE AND STORE

FOR REUSE

2. REMOVE EXISTING PARTITION IN ITS ENTIRETY

3. EXPAND EXISTING GWB WRAPPED OPENING TO CLOSET WALL. REFRAME HEADER FOR LARGER OPENING.

HEAD HEIGHT TO REMAIN THE SAME.

4. DEMOLISH EXISTING CASEWORK AND LOW PARTITIONS.

5. REMOVE EXISTING LOCKERS.

6. REMOVE EXISTING BENCH

7. DEMOLISH EXISTING COUNTERTOP, SINKS, CABINET, AND MIRROR

8. REMOVE EXISTING FLOOR FINISH. PREP SURFACE FOR NEW FLOOR FINISH

9. NOT USED

10. EXPAND EXISTING DOOR FRAMING TO ACCOMODATE LARGER DOOR, SEE DOOR SCHEDULE

11. REMOVE EXISTING DOOR ASSEMBLY IN IT'S ENTIRETY

12. CUT SLAB TO TIE NEW TRENCH DRAIN INTO EXISTING FLOOR DRAIN SYSTEM, SEE PLUMING DRAWINGS

13. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL ON ONE SIDE AS INDICATED BY DASHED LINE

14. REMOVE EXISTING WALL CABINETS AND SALVAGE FOR RE-USE

15. REMOVE EXISTING BASE CABINETS AND COUNTERTOP

16. REMOVE EXISTING PLUMBING FIXTURE

17. REMOVE EXISTING WASHER AND DRYER - COORDINATE WITH OWNER

18. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL AS INDICATED BY DASHED LINE

19. REMOVE EXISTING GWB ON UNISEX RESTROOM SIDE OF WALL AS INDICATED BY DASHED LINE

20. REMOVE EXISTING DOOR AND HARDWARE. FRAME CAN REMAIN IN PLACE. PREP EXISTING FRAME FOR

NEW DOOR AND HARDWARE.

G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS

AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO

COMMENCMENT OF WORK.

F. THE CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY

THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED. ANY

QUESTIONS SHALL PROMPTLY REFERRED TO THE ARCHITECT FOR RESOLUTION.

E. CONTRACTOR IS RESPONSIBLE FOR CUTTING AND PATCHING OF FLOORS, WALLS, AND

CEILINGS. PATCH ALL AREAS REQUIRE TO ACCEPT NEW HVAC, PLUMBING, AND

ELECTRICAL WORK. PATCH AND REPAIR TO A FINISHED CONDITION INDICATED IN THE

DRAWINGS OR TO MATCH EXISTING.

D. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING

SURFACES, MATERIALS, AND COMPONENTS TO REMAIN. ANY DAMAGE RESULTING

FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED BY THE CONRACTOR T...

C. WHERE DEMOLITION WORK EXPOSED AND UNFINISHED SURFACE OR CONDITION IN A

SURFACE TO REMAIN EXPOSED, THE CONTRACTOR SHALL PATCH, REPAIR, AND

PREPARE SUCH SURFACE OR CONDITION AS REQUIRED TO PROPERLY RECEIVE NEW

FINISHES AND TO MATCH THE EXISTING ADJACENT SURFACE.

B. ALL EXISTING SURFACE LOCATED ADJACENT TO DEMOLITION WORK AND SCHEDULE

TO REMAIN EXPOSED AFTER COMPLETION OF NEW CONSTRUCTION SHALL BE

REPAIRED AND PATCHED AS REQUIRED TO MATCH EXISTING.

A. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION WORK

AND SCHEDULED TO RECEIVE NEW CONSTRUCTION, SHALL BE REPAIRED AND

PATCHED AS REQUIRED TO CLEANLY AND SOUNDLY RECEIVE NEW WORK.

GENERAL DEMOLITION PLAN NOTES

AD102 1/8" = 1'-0" REF:2/A401

SECOND FLOOR DEMOLITION PLAN 1

KEY NOTES - RCP DEMOLITION

NO. DESCRIPTION

1. REMOVE EXISTING CEILING AND FIXTURES AND PREP FOR NEW WORK. SALVAGE EXISTING CEILING TILES

FOR POSSIBLE REUSE. COORDINATE WITH OWNER

3. RECONFIGURE EXISTING BULKHEAD TO ACCOMODATE NEW WORK

A102

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

STORAGE

UNISEX RR

MOTHER'S ROOM

QUIET ROOM

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

034WOMEN'S LOCKERS

MEN'S RR

BEDROOM

BEDROOM

BEDROOM

NO NEW WORK

MEN'S LOCKERS

A101

STAGING

DECONTAMINATION

FIRE POLE

125b

CAPTAIN OFFICE

FITNESS

CORRIDOR

MECHANICAL/ELECTRICAL

T'COM. CLOSET

121CLOSET

NO NEW WORK

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

A100

250060

ERS TLG

OVERALL PLANS

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

A100 1/8" = 1'-0" REF:2/A401

SECOND FLOOR PLAN 2

A100 1/8" = 1'-0" REF:3/A403

FIRST FLOOR PLAN 1

N

UP

CAPTAIN OFFICE

CORRIDOR

CLOSET

T'COM. CLOSET

MECHANICAL/ELECTRICAL

STAGING

A403

AL

IG

N

FIRE POLE

125b

DECONTAMINATION

113 FITNESS

S3A-4

S3E-2a

S3E-2a

S3B-2

DI

M . P

ER

M

FR

. I

NS

TA

LL

AT

IO

N

'-1 /2

2'-9"

1'-9 1/8"

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

A101

250060

ERS TLG

FIRST FLOOR

PLAN

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

KEY NOTES - FLOOR PLAN

NO. DESCRIPTION

1. NOT USED

2. NEW WALL TO ALIGN WITH EDGE OF EXISTING GWB CEILING

3. NEW VENTED LOCKER WITH BENCH, 24" W X 24" D X 84" TALL

4. SHOWER WITH HOSE BIB

5. NEW DOOR AT FIRE POLE IS PART OF BASE BID. REUSE EXISTING DOOR AS PART OF

ALTERNATE 1

6. EXISTING FIRE POLE OPENING

7. FUTURE EXTRACTOR, PROVIDE ROUGH-INS ONLY

8. EXTEND LOCKER FRONT, DRAWER BASE FRONT, AND BENCH AROUND CORNER AND TO

END WALL AS SHOWN TO CREATE CONTINUOUS INSTALLATION

9. INFILL WALL WHERE DOOR IS REMOVED TO MATCH SURROUNDING CONSTRUCTION

10. INSTALL MOISTURE RESISTANT GWB, FULL HEIGHT OF STUDS, ON DECONTAMINATION

SIDE OF EXISTING WALLS AND BULKHEADS. INSULATE AND SEAL WALLS FOR ACOUSTIC

RATING OF 40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.

11. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE, ADD ACOUSTIC

INSULATION AND MOISTURE RESISTANT GWB TO LAUNDRY ROOM SIDE OF WALL, ADD

AN ADDITIONAL LAYER OF GWB TO BUNKROOM SIDE OF WALL, AND SEAL TO MEET

ACOUSTIC RATING OF 50 STC MIN. DEPENDING ON EXISTING WALL CONSTRUCTION.

12. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE.

13. INSTALL MOISTURE RESISTANT GWB ON UNISEX RESTROOM SIDE OF WALL, EXTEND TO

UNDERSIDE OF GWB LID ABOVE. INSULATE AND SEAL WALLS FOR ACOUSTIC RATING OF

40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.

14. CORNER GUARD

15. 18" DEEP ADJUSTABLE SHELVES ON STANDARDS, PROVIDE FIVE SHELVES

16. FLOOR FINISH MATERIALTRANSITION LINE - SEE SHEET A601 FOR DETAILS

17. PROVIDE HOLLOW METAL FRAME CASED OPENING

H. ALL INTERIOR WALLS ARE S3A-2a UNLESS NOTED OTHERWISE ON THE FLOOR PLANS.

G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS

AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO

COMMENCMENT OF WORK.

F. INSTALL BLOCKING INSIDE WALL FOR INSTALLATION OF WALL HUNG EQUIPMENT

INCLUDING OWNER PROVIDED EQUIPMENT. COORDINATION LOCATION OF BLOCKING

WITH ARCHITECT PRIOR TO INSTALLATION.

E. MANUFACTURERS LISTED IN THE CONSTRUCTION DOCUMENTS ARE FOR

"BASIS-OF-DESIGN". SUBSTITUTIONS SHALL MEET OR EXCEED THE PERFORMANCE

REQUIREMENTS AND ASTM STANDARDS LISTED IN THE SPECIFICATIONS TO BE

CONSIDERED AN APPROVED EQUAL BY THE OWNER AND ARCHITECT OF RECORD.

D. ALL GYPSUM WALL BOARD SHALL BE 5/8" TYPE 'X' UNLESS NOTED OTHERWISE.

PROVIDE LEVEL 4 FINISH UNLESS NOTED OTHERWISE.

C. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.

B. ALL DOOR FRAMES ARE LOCATED 4-INCHES FROM ADJACENT WALL UNLESS NOTED

OTHERWISE.

A. ALL DIMENSIONS ARE SHOWN TO FACE OF STUD, MASONRY, OR COLUMN

CENTERLINES UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS CLEAR

("CLR") INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH.

GENERAL FLOOR PLAN NOTES

I. INSTALL CORNER GUARDS ON ALL OUTSIDE CORNERS AS NOTED ON PLANS

H. PROVIDE SEALANT SAMPLES FOR SELECTION BY THE ETICA GROUP FOR ALL INTERIOR

SEALANT APPLICATIONS. CLEAR SILCONE SEALANTS ARE NOT ACCEPTABLE.

G. REFER TO INTERIOR ELEVATIONS & SECTIONS WHERE PROVIDED FOR ADDITIONAL

FINISH INFORMATION. NOTE ANY DISCREPANCIES TO THE ETICA GROUP.

F. SUBMIT SAMPLES OF MILLWORK, CASWORK AND WOOD DOORS (STAINED OR PAINTED)

TO ETICA GROUP FOR REVIEW AND APPROVAL PRIOR TO FINISHING OF MATERIALS.

E. FOR CHANGES IN FLOOR MATERIAL, PROVIDE TRANSITION STRIPS BETWEEN FLOORING

OF DIFFERING MATERIALS. WHERE MATERIAL CHANGES AT A DOOR OPENING, FINISH

CHANGE SHOULD OCCUR CENTERED UNDER THE DOOR.

D. ALL AREAS TO RECEIVE PAINT ARE TO RECEIVED PRIMER COAT AND TWO COATS OF

FINISH.

C. FOR NEW ELECTRICAL, THERMOSTATS AND OTHER DEVICES, COORDINATION COLOR

SELECTION WITH ETICA GROUP PRIOR TO INSTALLATION.

B. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CONSTRUCTION AS INDICATED.

WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0". VERIFY

FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK

WHETHER OR NOT INDICATED ON DRAWINGS.

A. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE 2014

INDIANA BUILDING CODE FOR CLASS C FIRE RATINGS.

GENERAL FINISH NOTES

A101 1/4" = 1'-0" REF:1/A100

LEVEL 1 FLOOR PLAN 1

N

A501

8' -1 1/ 4"

8' -1 3/ 4"

11'-4 1/4" 5'-4 7/8" 7'-3 3/4" 2'-10" 2'-10" +/-6'-11 1/2"

2' -1 0"

5' -4 /8

'-4 /4

5'-4 7/8" 11'-0 5/8"

94 SF

BEDROOM

94 SF

BEDROOM

124 SF

BEDROOM

98 SF

BEDROOM

94 SF

BEDROOM

94 SF

BEDROOM

94 SF

BEDROOM

94 SF

BEDROOM

13 SF

STORAGE

73 SF

UNISEX RR

49 SF

MOTHER'S ROOM

330 SF

QUIET ROOM

81 SF

MECHANICAL

03146 SF

VESTIBULE

474 SF

CORRIDOR

43 SF

VESTIBULE

172 SF

WOMEN'S LOCKERS

A401

A401

A401

A401

A402

008007006

005004

98 SF

BEDROOM

124 SF

BEDROOM

94 SF

BEDROOM

S3B-2

S3B-2

S3B-2a

S3B-2

4' -1 /4

4' -1 /2

6"6"

S3A-1S3A-1 15

S3A-1

S3B-2a

S3E-2a

S3E-2a 16 16

8' -1 3/ 4"

8' -1 1/ 4"

S3B1

3/ 4"

3/ 4"

P-2

P-2

P-2

P-2

4'-1 1/4" 3 5/8" 8'-4" 3 5/8" EQ.

5'-0" CLR.

EQ. 3 5/8" EQ. 3 5/8" 8'-4" 3 5/8" 4'-1 1/4"

DI

M . P

ER

M

FR

. I

NS

TA

LL

AT

IO

N

'-1 /2

3'-0" 10'-2 7/8" 3 5/8"

WOMEN'S RR

WOMEN'S SHOWER

MEN'S RR

MEN'S SHOWER

JANITOR'S

MEN'S LOCKERS

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

A102

250060

ERS TLG

SECOND FLOOR

PLAN

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

A102 1/4" = 1'-0"

SECOND FLOOR PLAN 1

KEY NOTES - FLOOR PLAN

NO. DESCRIPTION

1. NOT USED

2. NEW WALL TO ALIGN WITH EDGE OF EXISTING GWB CEILING

3. NEW VENTED LOCKER WITH BENCH, 24" W X 24" D X 84" TALL

4. SHOWER WITH HOSE BIB

5. NEW DOOR AT FIRE POLE IS PART OF BASE BID. REUSE EXISTING DOOR AS PART OF

ALTERNATE 1

6. EXISTING FIRE POLE OPENING

7. FUTURE EXTRACTOR, PROVIDE ROUGH-INS ONLY

8. EXTEND LOCKER FRONT, DRAWER BASE FRONT, AND BENCH AROUND CORNER AND TO

END WALL AS SHOWN TO CREATE CONTINUOUS INSTALLATION

9. INFILL WALL WHERE DOOR IS REMOVED TO MATCH SURROUNDING CONSTRUCTION

10. INSTALL MOISTURE RESISTANT GWB, FULL HEIGHT OF STUDS, ON DECONTAMINATION

SIDE OF EXISTING WALLS AND BULKHEADS. INSULATE AND SEAL WALLS FOR ACOUSTIC

RATING OF 40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.

11. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE, ADD ACOUSTIC

INSULATION AND MOISTURE RESISTANT GWB TO LAUNDRY ROOM SIDE OF WALL, ADD

AN ADDITIONAL LAYER OF GWB TO BUNKROOM SIDE OF WALL, AND SEAL TO MEET

ACOUSTIC RATING OF 50 STC MIN. DEPENDING ON EXISTING WALL CONSTRUCTION.

12. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE.

H. ALL INTERIOR WALLS ARE S3A-2a UNLESS NOTED OTHERWISE ON THE FLOOR PLANS.

G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS

AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO

COMMENCMENT OF WORK.

F. INSTALL BLOCKING INSIDE WALL FOR INSTALLATION OF WALL HUNG EQUIPMENT

INCLUDING OWNER PROVIDED EQUIPMENT. COORDINATION LOCATION OF BLOCKING

WITH ARCHITECT PRIOR TO INSTALLATION.

E. MANUFACTURERS LISTED IN THE CONSTRUCTION DOCUMENTS ARE FOR

"BASIS-OF-DESIGN". SUBSTITUTIONS SHALL MEET OR EXCEED THE PERFORMANCE

REQUIREMENTS AND ASTM STANDARDS LISTED IN THE SPECIFICATIONS TO BE

CONSIDERED AN APPROVED EQUAL BY THE OWNER AND ARCHITECT OF RECORD.

D. ALL GYPSUM WALL BOARD SHALL BE 5/8" TYPE 'X' UNLESS NOTED OTHERWISE.

PROVIDE LEVEL 4 FINISH UNLESS NOTED OTHERWISE.

C. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.

B. ALL DOOR FRAMES ARE LOCATED 4-INCHES FROM ADJACENT WALL UNLESS NOTED

OTHERWISE.

A. ALL DIMENSIONS ARE SHOWN TO FACE OF STUD, MASONRY, OR COLUMN

CENTERLINES UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS CLEAR

("CLR") INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH.

GENERAL FLOOR PLAN NOTES

I. INSTALL CORNER GUARDS ON ALL OUTSIDE CORNERS AS NOTED ON PLANS

H. PROVIDE SEALANT SAMPLES FOR SELECTION BY THE ETICA GROUP FOR ALL INTERIOR

SEALANT APPLICATIONS. CLEAR SILCONE SEALANTS ARE NOT ACCEPTABLE.

G. REFER TO INTERIOR ELEVATIONS & SECTIONS WHERE PROVIDED FOR ADDITIONAL

FINISH INFORMATION. NOTE ANY DISCREPANCIES TO THE ETICA GROUP.

F. SUBMIT SAMPLES OF MILLWORK, CASWORK AND WOOD DOORS (STAINED OR PAINTED)

TO ETICA GROUP FOR REVIEW AND APPROVAL PRIOR TO FINISHING OF MATERIALS.

E. FOR CHANGES IN FLOOR MATERIAL, PROVIDE TRANSITION STRIPS BETWEEN FLOORING

OF DIFFERING MATERIALS. WHERE MATERIAL CHANGES AT A DOOR OPENING, FINISH

CHANGE SHOULD OCCUR CENTERED UNDER THE DOOR.

D. ALL AREAS TO RECEIVE PAINT ARE TO RECEIVED PRIMER COAT AND TWO COATS OF

FINISH.

C. FOR NEW ELECTRICAL, THERMOSTATS AND OTHER DEVICES, COORDINATION COLOR

SELECTION WITH ETICA GROUP PRIOR TO INSTALLATION.

B. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CONSTRUCTION AS INDICATED.

WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0". VERIFY

FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK

WHETHER OR NOT INDICATED ON DRAWINGS.

A. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE 2014

INDIANA BUILDING CODE FOR CLASS C FIRE RATINGS.

GENERAL FINISH NOTES

AL

IG

N

AL

IG

N

AL

IG

N

N

KEY NOTES - FLOOR PLAN

NO. DESCRIPTION

13. INSTALL MOISTURE RESISTANT GWB ON UNISEX RESTROOM SIDE OF WALL, EXTEND TO

UNDERSIDE OF GWB LID ABOVE. INSULATE AND SEAL WALLS FOR ACOUSTIC RATING OF

40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.

14. CORNER GUARD

15. 18" DEEP ADJUSTABLE SHELVES ON STANDARDS, PROVIDE FIVE SHELVES

16. FLOOR FINISH MATERIALTRANSITION LINE - SEE SHEET A601 FOR DETAILS

17. PROVIDE HOLLOW METAL FRAME CASED OPENING

S

SD

SD

NEW DEMO EXISTING TO REMAIN

GYPSUM BOARD

CEILING

CEILING GRID,

SUSPENDED, 2' X 4'

CEILING GRID,

SUSPENDED, 2' X 2'

CEILING GRID,

SUSPENDED, 2' X 4'

CEILING GRID,

SUSPENDED, 2' X 2'

GYPSUM BOARD

CEILING

GYPSUM BOARD

CEILING

CEILING GRID,

SUSPENDED, 2' X 4'

CEILING GRID,

SUSPENDED, 2' X 2'

ACT-12

12'-0" A.F.F.

REFLECTED CEILING PLAN LEGEND

RETURN AIR

DIFFUSER

SUPPLY AIR

DIFFUSER

2 X 2 LIGHT FIXTURE,

EMERGENCY

LINEAR LIGHT

FIXTURE

SPRINKLER HEAD

(VARIES)

EMERGENCY EXIT

LIGHT

2 X 4 LIGHT FIXTURE

CEILING TYPE

CEILING HEIGHT

CAN LIGHT FIXTURE

DIRECTIONAL EXIT

SIGN

2 X 2 LIGHT FIXTURE

SPEAKER

OCCUPANCY

SENSOR

S

SMOKE DETECTORSD

CEILING FAN

A403

CAPTAIN OFFICE

CORRIDOR

CLOSET

T'COM. CLOSET

MECHANICAL/ELECTRICAL

STAGING

FITNESS

FIRE POLE

125b

DECONTAMINATION

ACT-1

9'-0"A.F.F.

ACT-2

9'-0"A.F.F.

ACT-1

9'-0"A.F.F.

ACT-1

8'-0"A.F.F.

GWB

8'-0"A.F.F.

CHECKED BY:DATE ISSUED: DRAWN BY:

PROJECT NUMBER:

PROFESSIONAL SEAL:

DRAWING TITLE:

SHEET NUMBER:

This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.

constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.

disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.

DISCLAIMER:

ISSUED FOR CONSTRUCTION

8/ /2 :3 6:

P M

A ut od es k D oc s:

//2

- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t

A103

250060

ERS TLG

CEILING PLAN -

FIRST

R en ov at io n of S ta tio n

W . 1 th S t.

C ar m el , I N

C ity o f C ar m el

O ne C iv ic S qu ar e

C ar m el , I N

8/14/2026

KEY NOTES - CEILING PLAN

NO. DESCRIPTION

1 NEW GYPSUM BULKHEAD

2 OPEN TO GWB LID ABOVE

H. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED DIFFUSERS, GRILLE TYPES AND

QUANTITIES.

G. REFER TO ELECTRICAL DRAWINGS FOR CEILING-MOUNTED LIGHT FIXTURE TYPES AND

QUANTITIES.

F. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS AND

REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO COMMENCMENT...

E. CEILING HEIGHTS TO MATCH EXISTING UNLESS NOTED OTHERWISE.

D. ALL NEW CEILINGS TO BE 2'X2' ACOUSTIC PANEL CEILING. REFER TO FINISH AND ROOM

SCHEDULES FOR TYPES.

C. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,

SMOKE DETECTORS, SPRINKLER HEADS, OCCUPANCY SENSORS, SPEAKERS, CEILING FANS,

AND EXIT SIGNS UNLESS OTHERWISE NOTED.

B. COORDINATION OF DUCTWORK, PIPING, LIGHTS AND CEILING SUPPORTS ARE THE

RESPONSIBILITY OF THE TRADE CONTRACTORS. CONTRACTORS WILL ACCEPT

RESPONSIBILITY TO RELOCATE ITEMS THAT CONFLICT DUE TO LACK OF COORDINATION.

A. ALL NEW CEILING GRIDS ARE CENTERED IN ROOMS IN EACH DIRECTION UNLESS NOTED

OTHERWISE. NO TILE SHOULD BE LESS THAN 6-INCHES WIDE AT THE EDGES.

GENERAL CEILING PLAN NOTES

A103 1/4" = 1'-0" REF:3/A403

LEVEL 1 CEILING 1

N

S

S

S

S S

S

S S

S

S

S

S

S

S

S S

S

SS

S

S

SD

SD

SD

SD

SD

SD

SD SD

SD

SD SD

SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

NEW DEMO EXISTING TO REMAIN

GYPSUM BOARD

CEILING

CEILING GRID,

SUSPENDED, 2' X 4'

CEILING GRID,

SUSPENDED, 2' X 2'

CEILING GRID,

SUSPENDED, 2' X 4'

CEILING GRID,

SUSPENDED, 2' X 2'

GYPSUM BOARD

CEILING

GYPSUM BOARD

CEILING

CEILING GRID,

SUSPENDED, 2' X 4'

CEILING GRID,

SUSPENDED, 2' X 2'

ACT-12

12'-0" A.F.F.

REFLECTED CEILING PLAN LEGEND

RETURN AIR

DIFFUSER

SUPPLY AIR

DIFFUSER

2 X 2 LIGHT FIXTURE,

EMERGENCY

LINEAR LIGHT

FIXTURE

SPRINKLER HEAD

(VARIES)

EMERGENCY EXIT

LIGHT

2 X 4 LIGHT FIXTURE

CEILING TYPE

CEILING HEIGHT

CAN LIGHT FIXTURE

DIRECTIONAL EXIT

SIGN

2 X 2 LIGHT FIXTURE

SPEAKER

OCCUPANCY

SENSOR

S

SMOKE DETECTORSD

CEILING FAN

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

1 1 1

A501

A501

A402

STORAGE

UNISEX RR

MOTHER'S ROOM

QUIET ROOM

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

WOMEN'S LOCKERS

BEDROOM

BEDROOM

BEDROOM

1'-0"

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

GWB

7'-6"A.F.F.

GWB

7'-6"A.F.F.

GWB

7'-6"A.F.F.

G W B

7' -6 "A .F .F

G W B

7' -6 "A .F .F

GWB

7'-6"A.F.F.

ACT-1

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

GWB

7'-10"A.F.F.

ACT-2

8'-0"A.F.F.

ACT-1

8'-0"A.F.F.

A501

Si…