Station_346_-_Construction_Documents.pdf
PDF 20 MB Posted
- Attached to
- CFD Stations Remodel Project
- Solicitation number
- IFB-2026-012
- Issued by
- Hamilton County, Indiana
About this file
Construction Documents Summary
This document is a comprehensive set of construction drawings for the Renovation of Station 46 of the Carmel Fire Department, located at 540 W. 136th Street, Carmel, Indiana 46032. The project encompasses architectural, mechanical, electrical, plumbing, fire protection, and technology systems for a two-story fire station with a total building area of 11,390 square feet (5,125 SF on the first floor and 6,265 SF on the second floor). The renovation scope includes creating individual sleeping rooms and associated upgrades on the second floor and installing new decontamination facilities on the first floor. The facility is classified as Business Group B (Fire Station) construction with Type V-B construction type, permitting two stories. The building contains 59 rooms including 11 bedrooms, multiple restrooms, locker rooms, exercise and fitness areas, a decontamination room, apparatus bay, and various support spaces. The drawings indicate the project was issued for construction on August 14, 2026, and include demolition plans for both floors, electrical systems, mechanical and HVAC systems, plumbing infrastructure, fire protection systems, and technology provisions.
The construction documents specify detailed requirements for interior finishes, wall assemblies with acoustic and fire-rated specifications, casework and millwork installations, and various mechanical and electrical systems. All interior walls are designated as S3A-2a construction type unless noted otherwise, with specific wall types identified for acoustic performance ratings ranging from 47 to 56 STC. The project includes provisions for moisture-resistant gypsum wall board in wet areas, solid surface countertops and backsplashes, and various finish materials including carpet tile, sealed concrete, and ceramic tile flooring. The documents reference multiple alternates, including Alternate 1 for upgrading an existing laundry room into a decontamination facility, Alternate 2 for custom solid wood millwork bunk beds, and Alternate 3 for alternative flooring finishes. All work must comply with the 2012 International Building Code with 2014 Indiana amendments and related state and local codes. The general contractor is responsible for coordination with the owner regarding on-site activities, dust control through partitions, material staging, and daily cleanup procedures to maintain safe operations during construction.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATION 46
VICINITY MAP
CONTRACTOR PARKING
AND STAGING
STAGING MAP
OFF LIMITS
DRAWING INDEX
ARCHITECTURAL
Sheet Number NAME
A001 GENERAL INFORMATION
A002 FIRE & LIFE SAFETY PLANS
AD101 FIRST FLOOR DEMOLITION PLANS
AD102 SECOND FLOOR DEMOLITION PLANS
A100 OVERALL PLANS
A101 FIRST FLOOR PLAN
A102 SECOND FLOOR PLAN
A103 CEILING PLAN - FIRST
A104 CEILING PLAN - SECOND
A401 LARGE SCALE VIEWS
A402 LARGE SCALE VIEWS
A403 LARGE SCALE VIEWS
A501 DETAILS
A600 DOOR & WINDOW SCHEDULES, ELEVATIONS
A601 ROOM FINISH SCHEDULE
ELECTRICAL
Sheet Number NAME
E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E101 FIRST FLOOR ELECTRICAL DEMOLITION FLOOR PLAN
E102 SECOND FLOOR ELECTRICAL DEMOLITION FLOOR PLAN
E301 FIRST FLOOR LIGHTING FLOOR PLAN
E302 SECOND FLOOR LIGHTING FLOOR PLAN
E311 FIRST FLOOR POWER AND SYSTEMS FLOOR PLAN
E312 SECOND FLOOR POWER AND SYSTEMS FLOOR PLAN
E501 ELECTRICAL DETAILS
E601 ELECTRICAL SCHEDULES
E701 ELECTRICAL DIAGRAMS
M001 MECHANICAL SYMBOLS AND ABBREVIATIONS
M101 FIRST FLOOR MECHANICAL DEMOLITION PLAN
M111 SECOND FLOOR MECHANICAL DEMOLITION PLAN
M301 FIRST FLOOR MECHANICAL PLAN
M311 SECOND FLOOR MECHANICAL PLAN
M312 SECOND FLOOR PIPING PLAN
M401 FIRST FLOOR ENLARGED PIPING PLAN
M501 MECHANICAL DETAILS
M502 MECHANICAL DETAILS
M601 MECHANICAL SCHEDULES
M602 MECHANICAL SCHEDULES
ME701 HVAC CONTROLS WIRING, DIAGRAMS, AND SEQUENCES
ME702 HVAC CONTROLS WIRING, DIAGRAMS, AND SEQUENCES
MECHANICAL
Sheet Number NAME
PLUMBING
Sheet Number NAME
P001 PLUMBING SYMBOLS AND ABBREVIATIONS
P100 UNDERSLAB PLUMBING DEMOLITION FLOOR PLAN
P101 FIRST FLOOR PLUMBING DEMOLITION FLOOR PLAN
P111 SECOND FLOOR PLUMBING DEMOLITION FLOOR PLAN
P300 UNDERSLAB PLUMBING FLOOR PLAN
P301 FIRST FLOOR PLUMBING FLOOR PLAN
P311 SECOND FLOOR PLUMBING FLOOR PLAN
P501 PLUMBING DETAILS
P601 PLUMBING SCHEDULES
P701 PLUMBING DIAGRAMS
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica
Group, Inc. It is intended solely for use by The Etica
Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica
Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTIONMechanical, Electrical, Plumbing Engineer:
Architect, Civil Engineer:
Etica Group, Inc.
8720 Castle Creek Parkway East Drive, Suite 400
Indianapolis, IN 46250
(317) 466-9520 www.eticagroup.com
Technology Engineer:
/1
/2
:5
:5
A
M A u to d e s k D o c s
/2
C a rm e l F ir e
S ta tio n
/2
C a rm e l F ir e
S ta tio n
.r vt
G001
250060
ERS TLG
COVER
R e n o va tio n o f S ta tio n
W th S t.
C a rm e l, IN
C ity o f
C a rm e l
O n e C iv ic
S q u a re
C a rm e
8/14/2026
Renovation of Station 46
8/14/2026
540 W. 136th St. Carmel, IN 46032
City of Carmel
ISSUED FOR CONSTRUCTION
FIRE PROTECTION
Sheet Number NAME
FP001 FIRE PROTECTION SYMBOLS AND ABBREVIATIONS
FP101 FIRST FLOOR FIRE PROTECTION DEMOLITION
FP111 SECOND FLOOR FIRE PROTECTION DEMOLITION
FP301 FIRST FLOOR FIRE PROTECTION FLOOR PLAN
FP311 SECOND FLOOR FIRE PROTECTION FLOOR PLAN
TECHNOLOGY
Sheet Number NAME
T000 SYMBOLS AND ABBREVIATIONS
TD101 TECHNOLOGY FIRST FLOOR DEMOLITION
TD102 TECHNOLOGY SECOND FLOOR DEMOLITION
T101 TECHNOLOGY FIRST FLOOR PLAN
T102 TECHNOLOGY SECOND FLOOR PLAN
T501 TECHNOLOGY DETAILS
T502 TECHNOLOGY DETAILS
REVISION SCHEDULE
# DESCRIPTION DRAWN BY DATE ISSUED
LOCUTION SYSTEM
Sheet Number NAME
---- LOCUTION SYSTEM DESIGN BY ERS FOR REFERENCE ONLY
UP
• 2012 INTERNATIONAL BUILDING CODE W/ 2014 INDIANA AMENDMENTS
• 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007)
• 2006 INTERNATIONAL PLUMBING CODE W/ 2012 INDIANA AMENDMENTS
• 2008 NATIONAL ELECTRIC CODE W/ 2009 INDIANA AMENDMENTS
• 2012 INTERNATIONAL MECHANICAL CODE W/ 2014 INDIANA AMENDMENTS
• 2012 INTERNATIONAL FIRE CODE W/ 2014 INDIANA AMENDMENTS
PROJECT LOCATION:
540 W. 136th ST.
CARMEL, IN 46032
PROJECT SCOPE:
CARMEL FIRE DEPARTMENT STATION 46 IS BEING RENOVATED TO PROVIDE INDIVIDUAL SLEEPING ROOMS AND ASSOCIATED UPGRADES ON THE SECOND FLOOR AND NEW DECONTAMINATION FACILITIES ON THE FIRST FLOOR.
OCCUPANCY CLASSIFICATION:
BUSINESS GROUP B - FIRE STATION (SECTION 304.1)
CONSTRUCTION TYPE:
TYPE V-B (SECTION 602.5)
ALLOWABLE AREA (PER STORY): (SECTION 506.1)
TABULAR AREA: 9,000 SF (TABLE 503)
FRONTAGE INCREASE: 6,750 SF (SECTION 506.2)
SPRINKLER INCREASE: 18,000 SF (SECTION 506.3)
TOTAL ALLOWABLE: 33,750 SF
TOTAL BUILDING SF: 11,390 SF 1ST FLOOR
5,125 SF 2ND FLOOR & MEZZANINE
16,515 SF TOTAL
ALLOWABLE HEIGHT AND STORIES:
TWO-STORIES PERMITTED FOR BUILDINGS OF GROUP B OCCUPANCY AND TYPE V-B CONSTRUCTION. FACILITY IS TWO-
STORY.
BUILDING ELEMENTS, FIRE RESISTIVE REQUIREMENTS (SECTION 602.5)
STRUCTURAL FRAME 0 HRS(TABLE 601 & 602)
BEARING WALLS
EXTERIOR 0 HRS
INTERIOR 0 HRS
NONBEARING WALLS / PARTITIONS EXTERIOR 0 HRS
NONBEARING WALLS / PARTITIONS INTERIOR 0 HRS
FLOOR CONSTRUCTION 0 HRS
ROOF CONSTRUCTION 0 HRS
FIRE WALLS:
A FIRE WALL IS NOT REQUIRED SINCE THE ACTUAL AREA IS LESS THAN THE ALLOWABLE AREA.
FIRE BARRIERS:
STAIRWAYS ARE NOT REQUIRED TO BE ENCLOSED (SECTION 1009.3 EXCEPTION 4)
FIRE PARTITIONS:
NONE REQUIRED.
NON-RELATED INCIDENTAL USE SEPERATION: NOT REQUIRED (TABLE 509)
CORRIDORS: 0-HR (TABLE 1012.1)
DEADEND CORRIDOR: 50' MAX (1018.4 EXCEPTION 2)
COMMON PATH OF EGRESS: 100' MAX (TABLE 1014.3)
EXIT ACCESS TRAVEL DISTANCE: 300' MAX
AUTOMATIC SPRINKLER REQUIREMENTS:
THE EXISTING BUILDING IS SPRINKLERED.
AREA OF REFUGE
AREA OF REFUGE IS NOT REQUIRED (SECTION 1007.3 EXCEPTION 2)
PLUMBING FIXTURE COUNT
159 MEN (75%)
5 WC REQUIRED / 4 WC & 3 URINALS PROVIDED
3 LAVS REQUIRED / 4 LAVS PROVIDED
53 WOMEN (25%)
3 WC / 4 WC PROVIDED (INCLUDING UNISEX RR)
2 LAVS / 4 LAVS PROVIDED (INCLUDING UNISEX RR)
3 DF REQUIRED / 2 DF PROVIDED PLUS ACCESS TO DRINKING WATER IN KITCHEN
1 SS REQUIRED / 1 SS PROVIDED
VESTIBULE
ENTRY
CORRIDOR
PANTRY
PANTRY
PANTRY
KITCHEN
DINING ROOM
DAY ROOM
WATCH ALCOVE
TOILET
TOILET
CAPTAIN OFFICE
CORRIDOR
WATCH ROOM
STORAGE
EXERCISE
CLOSET
T'COM. CLOSET
MECHANICAL/ELECTRICAL
STAIR
STAGING
STAIR
FITNESS
FIRE POLE
125b
DECONTAMINATION
APPARATUS BAY
GEAR STORAGE
MAINTENANCE ROOM
GEAR STORAGE
132STORAGE
EMS STORAGE
NO NEW WORK
99' EXIT PATH
FEC
32' - 6": COMMON
PATH OF TRAVEL
STORAGE
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
STORAGE
UNISEX RR
MOTHER'S ROOM
QUIET ROOM
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
WOMEN'S LOCKERS
WOMEN'S RR
WOMEN'S SHOWER
MEN'S RR
MEN'S SHOWER
JANITOR'S
BEDROOM
BEDROOM
BEDROOM
NO NEW WORK
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
A002
250060
ERS TLG
FIRE & LIFE
SAFETY PLANS
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
CODE SUMMARY
A002 3/32" = 1'-0" REF:3/A403
FIRST FLOOR PLAN 1
A. FIRE EXTINGUISHERS: EXISTING FIRE EXTINGUISHER CABINETS AND EXTINGUISHERS
ARE TO REMAIN IN EXISTING LOCATIONS
LIFE SAFETY NOTES
A002 3/32" = 1'-0" REF:2/A401
SECOND FLOOR PLAN 2
Room Schedule Name Number Area Occupancy Occupant Level
LEVEL 1
VESTIBULE 101 87 SF 100 1 LEVEL 1
ENTRY 102 194 SF 100 1 LEVEL 1
CORRIDOR 103 64 SF 100 1 LEVEL 1
PANTRY 104 65 SF 300 1 LEVEL 1
PANTRY 105 56 SF 300 1 LEVEL 1
PANTRY 106 59 SF 300 1 LEVEL 1
KITCHEN 107 434 SF 15 28 LEVEL 1
DINING ROOM 108 310 SF 15 20 LEVEL 1
DAY ROOM 109 649 SF 15 43 LEVEL 1
WATCH ALCOVE 110 64 SF 100 1 LEVEL 1
TOILET 111 57 SF 100 1 LEVEL 1
TOILET 112 57 SF 100 1 LEVEL 1
DECONTAMINATION 113 125 SF 100 1 LEVEL 1
CAPTAIN OFFICE 114 142 SF 100 1 LEVEL 1
FITNESS 115 330 SF 50 6 LEVEL 1
CORRIDOR 116 37 SF 100 1 LEVEL 1
WATCH ROOM 117 473 SF 100 4 LEVEL 1
STORAGE 118 42 SF 100 1 LEVEL 1
EXERCISE 119 568 SF 50 11 LEVEL 1
CLOSET 120 29 SF 300 1 LEVEL 1
T'COM. CLOSET 121 51 SF 300 1 LEVEL 1
MECHANICAL/ELECT
RICAL
122 246 SF 300 1 LEVEL 1
STAIR 124 177 SF LEVEL 1
STAGING 125 657 SF 300 2 LEVEL 1
FIRE POLE 125b 31 SF 100 1 LEVEL 1
STAIR 126 176 SF LEVEL 1
APPARATUS BAY 127 3509 SF 300 11 LEVEL 1
GEAR STORAGE 128 283 SF 300 1 LEVEL 1
MAINTENANCE ROOM 129 225 SF 300 1 LEVEL 1
EMS STORAGE 130 64 SF 300 1 LEVEL 1
STORAGE 131 152 SF 300 1 LEVEL 1
GEAR STORAGE 132 284 SF 300 1 LEVEL 1
N
Room Schedule Name Number Area Occupancy Occupant Level
LEVEL 2
BEDROOM 001 94 SF 200 1 LEVEL 2
BEDROOM 002 94 SF 200 1 LEVEL 2
BEDROOM 003 124 SF 200 1 LEVEL 2
BEDROOM 004 98 SF 200 1 LEVEL 2
BEDROOM 005 94 SF 200 1 LEVEL 2
BEDROOM 006 94 SF 200 1 LEVEL 2
BEDROOM 007 94 SF 200 1 LEVEL 2
BEDROOM 008 98 SF 200 1 LEVEL 2
BEDROOM 009 124 SF 200 1 LEVEL 2
BEDROOM 010 94 SF 200 1 LEVEL 2
BEDROOM 011 94 SF 200 1 LEVEL 2
STORAGE 027 13 SF 300 1 LEVEL 2
UNISEX RR 028 73 SF 100 1 LEVEL 2
MOTHER'S ROOM 029 49 SF 100 1 LEVEL 2
QUIET ROOM 030 330 SF 15 19 LEVEL 2
MECHANICAL 031 81 SF 300 1 LEVEL 2
VESTIBULE 032 46 SF 100 1 LEVEL 2
CORRIDOR 033 474 SF 100 5 LEVEL 2
VESTIBULE 034 43 SF 100 1 LEVEL 2
WOMEN'S LOCKERS 035 172 SF 100 1 LEVEL 2
WOMEN'S RR 036 52 SF 100 1 LEVEL 2
WOMEN'S SHOWER 037 63 SF 100 1 LEVEL 2
MEN'S RR 038 160 SF 100 1 LEVEL 2
MEN'S SHOWER 039 108 SF 100 1 LEVEL 2
MEN'S LOCKERS 040 467 SF LEVEL 2
JANITOR'S 041 39 SF 300 1 LEVEL 2
STORAGE 217 868 SF 300 3 LEVEL 2
Grand total: 59 13840 SF
N
REVISION SCHEDULE
# DESCRIPTION DRAWN BY DATE ISSUED
CONCRETE
REGION TYPES TAGS
MATERIAL TAG
W12A WALL TAG
AREA NAME
AREA TAG
CEIL-1 CEILING TAG
XXX DOOR TAG
SYMBOLS
ROOM TAG
1t WINDOW TAG
SPOT ELEVATION
A101
Ref
A101
Ref
A101
Ref
R1 REVISION TAG
N
Name Elevation
SECTION HEAD OPEN
SECTION HEAD NO ARROW
SECTION HEAD FILLED
NORTH ARROW
LEVEL HEAD
0 GRID HEAD
A101
ELEVATION MARK BODY EXTERIOR
CENTERLINE
A101
A
A101
A
ELEVATION MARK BODY INTERIOR
1 PLAN NOTE
OTHER SYMBOLS
XX MULTI-CATEGORY TAG
(TYPE MARK)
VIEW NAME
A199.9 1/8" = 1'-0"?
REF:R/R101
VIEW TITLE
32"X
99 20"
ACTUAL LOAD
EGRESS CAPACITY
REQUIRED EGRESS
WIDTH
ACTUAL EGRESS
WIDTH
EGRESS TAG
ROOM NAME
ROOM NUMBER
LIFE SAFETY TAG
ROOM FINISH TAG
150 SF
Name
ROOM NAME
WL-1BS-1
FLOR-1
ROOM NUMBER
ROOM AREA
OCCUPANT LOAD
ROOM NUMBER
FLOOR FINISH
WALL FINISH
BASE FINISH
EARTH
GRANULAR FILL
BRICK
WOOD
WOOD BLOCKING / HEAVY TIMBER
CONCRETE BLOCK
PLYWOOD
SAND, GYPSUM, OR AS NOTED
STEEL / METAL
RIGID INSULATION
BATT INSULATION
SOLID SURFACE / PLASTIC
MORTAR
ALUMINUM
ROOM PRESENTATION
TAG
NAME
REPLACED
ABD
AC
A/E
AFF
AHU
ALT
ALUM
ASPH
BOT
BD
BFLG
BIT
BJT
BLDG
BLK
BRG
BS
BUR
BRK
C/C
CJ
CLG
CLR
CMU
CNTR
CO
COL
COORD
CONC
CONT
CONTR
DBL
DEG
DEMO
DEPT
DIA
DIM
DL
DN
DR
DS
DTL
DWG
EF
EPDM
EIFS
EJ
ELEC
ELEV
ENG
EP
ETC
EST
EXG
EXP
EXT
ABANDONED
AIR CONDITIONING
ASPHALT EMULSION
ABOVE FINISH FLOOR
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ASPHALT
BOTTOM
BOARD
BASE FLASHING
BITUMINOUS
BED JOINT
BUILDING
BLOCK
BEARING
BOTH SIDES
BUILT UP ROOFING
BRICK
CENTER TO CENTER
CONTROL JOINT
CEILING
CLEAR
CONCRETE MASONRY UNIT
COUNTER FLASHING
CLEAN OUT
COLUMN
COORDINATE
CONCRETE
CONTINUOUS or CONTINUED
CONTRACTOR
DOUBLE
DEGREE
DEMOLITION
DEPARTMENT
DIAMETER
DIMENSION
DEAD LOAD
DOWN
DOOR
DOWN SPOUT
DETAIL
DRAWING
EXHAUST FAN
ETHYLENE PROPYLENE DIENE MONOMER
EXTERIOR INSULATION FINISH SYSTEM
EXPANSION JOINT
ELECTRICAL
ELEVATION or ELEVATOR
ENGINEER
ELECTRICAL PANEL
ETCETERA
ESTIMATE
EXISTING
EXPOSED
EXTERIOR
FB
FD
FIN
FLG
FSR
FLR
FP
FT
GA
GALV
GB
GC
GL
GR
GRV
GWB
GYP
HGT
HDWD
HDWR
HM
HORZ
HVAC
IN
INFO
INSUL
JT
LAM
LBS
LFT
LVR
LWC
MAS
MATL
MAX
MBR
MECH
MFR
MH
MIN
MISC
MO
MRD
MTD
MTD
MTG
MTL
N
NA
NIC
NO
NOM
NTS
FACE BRICK
FLOOR DRAIN
FINISHED
FLASHING
FLEXIBLE SHEET ROOFING
FLOOR
FALL PROTECTION
FOOT or FEET
GAUGE
GALVANIZED
GLASS BLOCK
GENERAL CONTRACTOR
GLASS
GRADE
GRAVITY ROOF VENT
GYPSUM WALL BOARD
GYPSUM
HEIGHT
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HEATING, VENTILATING,
AIR CONDITIONING
INCH
INFORMATION
INSULATION
JOINT
LAMINATED
POUNDS
LINEAR FOOT
LOUVER
LIGHT WEIGHT CONCRETE
MASONRY
MATERIAL
MAXIMUM
MODIFIED BITUMEN ROOFING
MECHANICAL
MANUFACTURER
MAN HOLE
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL ROOF DECK
MOUNTED
MOUNTED
MOUNTING
METAL
NORTH
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
OA
OC
OH
OPNG
PT
PCC
PERP
PL
PLAS
PLBG
PWD
PREFAB
PROJ
PSI
PP
PS
PV
PVC
QTY
RC
RD
RE
REINF
REQ'D
RFG
RS
RV
REV
SATT
SC
SD
SECT
SHT
SIM
SPECS
SS
STD
STL
T&G
TEMP
TERM
THK
TOM
TOS
TO
TYP
UNO
UNF
UTIL
VB
VCT
VR
VERT
VIF
OVERALL
ON CENTER
OVERHEAD
OPENING
PAINT
PRE-CAST CONCRETE
PERPENDICULAR
PLATE
PLASTIC
PLUMBING
PLYWOOD
PREFABRICATED
PROJECT
POUNDS PER SQUARE INCH
PIPE PENETRATION
PIPE SEAL
PLUMBING VENT
POLY VINYL CHLORIDE
QUANTITY
ROOF CORE
ROOF DRAIN
REFER TO
REINFORCING
REQUIRED
ROOFING
ROOF SUMP
RELIEF VENT
REVISION
SATELLITE DISH
SCUPPER
STORM DRAIN
SECTION
SHEET
SIMILAR
SPECIFICATIONS
STAINLESS STEEL
STANDARD
STEEL
TONGUE & GROOVE
TEMPERATURE
TERMINATION
THICK or THICKNESS
TOP OF MASONRY
TOP OF STEEL
TOP OF
TYPICAL
UNLESS NOTED OTHERWISE
UNFINISHED
UTILITY
VINYL BASE
VINYL COMPOSITION TILE
VAPOR RETARDER
VERTICAL
VERIFY IN FIELD
WHERE SOUND BATTS ARE INDICATED PROVIDE
CONTINUOUS ACOUSTICAL SEALANT, BOTH SIDES
CONTINUOUS BOTTOM TRACK ATTACH TO
STRUCTURE @ 24" O.C. MAX.
5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED
FIBERGLASS SOUND BATTS, WHERE INDICATED,
FULL DEPTH OF CAVITY
LINE OF CEILING
TOP TRACK, ATTACH TO STUDS W/ WAFERHEAD SCREWS HOLD
TOP TRACK, VERTICAL STUDS & GWB DOWN FROM STRUCTURE
1.5" (OR 1.25 X ANTICIPATED LIVE LOAD DEFLECTION) TO
ALLOW FOR DEFLECTION OF STRUCTURE, TYP.
CONTINUOUS DEEP LEG TRACK (2 1/2" FLANGES) ATTACH
TO STRUCTURE ABOVE @ 16" O.C. DO NOT SECURELY
FASTEN TO TOP TRACK, VERTICAL STUDS OR GWB, TYP.
WHERE SOUND BATTS INDICATED PROVIDE
ACCOUSTICAL SEALANT ALL EDGES (BOTH SIDES), TYP.
LINE OF DECK OR STRUCTURE ABOVE
FIRE SAFING, BOTH SIDES AT RATED WALLS, TYP.
WALL BASE PER FINISH SCHEDULE
LINE OF STRUCTURE BELOW
METAL STUDS - 25 GA MIN., FOR SOUND CONTROL
WHERE SOUND BATTS ARE INDICATED PROVIDE
CONTINUOUS ACOUSTICAL SEALANT, BOTH SIDES
CONTINUOUS BOTTOM TRACK ATTACH TO
STRUCTURE @ 2' O.C. MAX.
5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED
METAL STUDS - 25 GA MIN., FOR SOUND CONTROL
FIBERGLASS SOUND BATTS,
WHERE INDICATED (FULL DEPTH OF CAVITY)
LINE OF CEILING
(4) SCREWS
METAL STUD BRACE CONT. TO STRUCTURE @ 4' 0" O.C.
MAX. (UNLESS NOTED OTHERWISE) EITHER SIDE OF WALL
TO CLEAR OTHER CONSTRUCTION ITEMS, SIZE TO MATCH
WALL STUDS, TYP. MAX. SLOPE NOT TO EXCEED 1:1
(4) POWDER DRIVEN FASTENERS W/
GALV. WASHERS
LINE OF STRUCTURE ABOVE
WALL BASE PER FINISH SCHEDULE
6"
LINE OF STRUCTURE BELOW
CONTINUOUS BOTTOM TRACK ATTACH TO
STRUCTURE @ 2' O.C. MAX.
5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED
SOLID SURFACE TOP
AT LOCATIONS WITH HANDRAILS OR COUNTERS,
PROVIDE MOMENT CLIP AT EA. STUD, FASTEN TO STUDS
WITH (6) SCREWS, SECURELY FASTEN TO FLOOR.
REFER TO STRUCTURAL NOTES
WALL BASE PER FINISH SCHEDULE
LINE OF STRUCTURE BELOW
WOOD BLOCKING FOR TOP OR RAILING
METAL STUDS - 25 GA MIN., FOR SOUND CONTROL
WHERE SOUND BATTS ARE INDICATED PROVIDE
CONTINUOUS ACOUSTICAL SEALANT, BOTH SIDES
CONTINUOUS BOTTOM TRACK ATTACH TO
STRUCTURE @ 24" O.C. MAX.
5/8" TYPE 'X' GWB ONE OR BOTH SIDES AS INDICATED
FIBERGLASS SOUND BATTS, WHERE INDICATED, FULL DEPTH OF CAVITY
LINE OF CEILING
TOP TRACK, ATTACH TO STUDS W/ WAFERHEAD SCREWS HOLD
TOP TRACK, VERTICAL STUDS & GWB DOWN FROM STRUCTURE
1.5" (OR 1.25 X ANTICIPATED LIVE LOAD DEFLECTION) TO
ALLOW FOR DEFLECTION OF STRUCTURE, TYP.
WHERE SOUND BATTS INDICATED PROVIDE
ACCOUSTICAL SEALANT ALL EDGES (BOTH SIDES), TYP.
WALL BASE PER FINISH SCHEDULE
LINE OF STRUCTURE BELOW
METAL STUDS - 25 GA MIN., FOR SOUND CONTROL
PARTITION DESIGNATION
FRAMING / CORE MATERIAL
HEIGHT CODE
PERFORMANCE REQUIREMENT
FINISH CONDITION
W6A - 2a
NOMINAL CORE SIZE
FRAMING/CORE MATERIAL
HEIGHT CODE PERFORMANCE REQUIREMENT
FINISH CONDITION
A – 1 LAYER GYP EACH SIDE
B – GYP ON ONE SIDE
C – 2 LAYERS GYP EACH SIDE
D – BACK TO BACK WET WALL
E – SINGLE LOAD WET WALL
F – SEE REMARKS
G – SEE REMARKS
H – SEE REMARKS
1 – 6” ABOVE CEILING
2 – TO DECK
3 – T0 CEILING
4 – AS INDICATED
5 – SEE NOTES
a – ACOUSTIC ASSEMBLY b – PENETRATION RESISTANT c – SHAFT WALL d – DAMAGE RESISTANT e – EPOXY COATED f – FIRE RATED g – FOIL FACED GYPSUM h – SEE REMARKS
C – CAST IN PLACE
E – ENGINEERED
METAL BUILDING
G – GLASS WALL
M – MASONRY
P – PRE-CAST
S – STEEL
W – WOOD
* 3'-6"
* 8"
WALL DEVICE, TYP. WALL DEVICE, TYP.
NOTE:
ALL WALL DEVICES TO BE
CENTER ALIGNED ON SAME SIDE
OF STUD (INCLUDING BUT NOT
LIMITED TO: ELECTRICAL,
MECHANICAL, FIRE PROTECTION,
AND LOW VOLTAGE ITEMS)
*MOVE DEVICE TO ALIGN WHEN DEVICES
ARE WITHIN DISTANCE INDICATED
ABOVE, UNLESS NOTED OTHERWISE
*MOVE DEVICE TO ALIGN WHEN
DEVICES ARE WITHIN 24" OF A
DOOR, UNLESS NOTED OTHERWISE
WALL TYPE NOTES
1. WALL TYPES DO NOT INCLUDE WALL FINISHES. SEE
ROOM FINISH SCHEDULE FOR FINISH INFORMATION.
2. COORDINATE RATING REQUIREMENTS INDICATED
ON SPECIFIC PARTITIONS WITH LIFE SAFETY PLAN.
3. ALL ACCOUSTIC AND FIRE RATED WALLS ARE TO
BE CONSTRUCTED IN ACCORDANCE WITH TESTING
AGENCY REQUIREMENTS. REFER TO SPECIFIC TEST
REPORTS FOR REQUIRED COMPONENTS AND
ASSEMBLY. SEE WALL TYPE REFERENCES AND LIFE
SAFETY SHEETS FOR RATED WALL LOCATIONS.
PROVIDE STOPPING PER MANUFACTURE’S
RECOMMENDATIONS FOR PENETRATIONS THROUGH
RATED WALLS.
4. ALL INTERIOR WALLS WHERE SOUND BATT
INSULATION IS INDICATED ARE CONSIDRED
ACOUSTIC WALLS. WHERE SPECIFIC STC RATINGS
ARE REQUIRED SEE INDIVIDUAL WALL TYPE
PARTITIONS.
5. AT STUD WALLS WHICH DO NOT EXTEND TO
STRUCTURE, PROVIDE BRACING 4'-0" O.C. AND AT
CENTERLINE OF DOOR OPENINGS.
6. PROVIDE WOOD BLOCKING AT TOP AND BOTTOM
OF CABINETS. COORDINATE HEIGHTS WITH
CASEWORK ELEVATIONS.
7. AT STUD WALLS, WOOD BLOCKING IS REQUIRED
AT ALL WALL MOUNTED ITEMS INCLUDING BUT NOT
LIMITED TO THE FOLLOWING LOCATIONS:
A. WALL MOUNTED COUNTERS AND COUNTERTOP
SUPPORTS.
B. WALL MOUNTED ACCESSORIES AND
EQUIPMENT
C. WALL MOUNTED DOORSTOPS
D. WALL MOUNTED DOOR HOLD OPEN DEVICES
AND/OR CLOSERS
E. TOILET ROOM PARTITIONS AND ACCESSORIES
F. WALL MOUNTED TV’S AND BRACKETS
G. OTHER LOCATIONS AS REQUIRED BY THE
ARCHITECT AND INDUSTRY STANDARDS.
8. INSTALL BLOCKING BETWEEN EXISTING
STRUCTURAL MEMBERS TO ALLOW PROPER
ATTACHMENT OF NEW PARTITIONS TO STURCTURE
ABOVE.
TYPE
PARTITION
WIDTH
CORE
SIZE
MAX. STUD
SPACING
O.C.
ACCOUSTIC
RATING
FIRE
RATING
UL
NUMBER
REMARKS
S3A 4 7/8" 3 5/8" 24" O.C. 47 STC 1 HR U465
S3B 4 1/4" 3 5/8" 24" O.C. --- --- ---
S3C 6 1/8" 3 5/8" 24" O.C. 56 STC 2 HR U411
S3D 3 5/8" 24" O.C. 47 STC 1 HR U465
MOISTURE
RESISTANT
GWB
S3E
3 5/8" 24" O.C. 47 STC 1 HR U465
MOISTURE
RESISTANT
GWB
S6A 6 7/8" 5 5/8" 24" O.C. 49 STC 1 HR U465
4 7/8"
4 7/8"
S3F 4 1/4" 3 5/8" 24" O.C. --- --- ---
MOISTURE
RESISTANT
GWB
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
A001
250060
ERS TLG
GENERAL
INFORMATION
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
ABBREVIATIONS
N. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT
TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS
AND EQUIPMENT.
M. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO ETICA GROUP, INC. FOR
APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE
FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A
SPECIFIC MANUFACTURER OR MODEL NUMBER.
L. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED
BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF
THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING
MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS
INDICATED ON THE CEILING PLAN).
K. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF
DAILY OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS
SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6 MIL VAPOR
BARRIER ON EACH SIDE.
J. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER, AN AREA FOR STAGING
OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION
AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE
APPROVED BY THE OWNER. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY
CONSTRUCTION CREWS.
I. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE OWNER CLEANUP PROCEDURES
AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN
A SAFE AND CLEAN ENVIRONMENT.
H. ETICA GROUP, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL
NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,
SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR
MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.
G. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH
APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT
TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.
F. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL
COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER
AND ETICA GROUP WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR
TO MEET THE PROJECT SCHEDULE. NEITHER THE OWNER NOR ARCHITECT IS RESPONSIBLE
FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL
LEAD TIMES.
E. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL
ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS
STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,
AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR
SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS
NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.
D. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY
DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO ETICA GROUP, INC.
C. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR
BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING
RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE
PRECEDENCE.
B. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS
CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK
REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK
SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE
OF WORK.
A. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL
BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT
APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.
GENERAL PROJECT NOTES
A001 1/2" = 1'-0"
STEEL STUD WALL FULL HEIGHT 1
A001 1/2" = 1'-0"
STEEL STUD WALL PARTIAL HEIGHT 2
A001 1/2" = 1'-0"
STEEL STUD WALL AS INDICATED 4
A001 1/2" = 1'-0"
STEEL STUD WALL TO CEILING 5
A001 3/8" = 1'-0"
DEVICE LOCATION DIAGRAM 7
EXISTING ITEM TO REMAIN
EXISTING WALL TO REMAIN
EXISTING DOOR & FRAME TO REMAIN
EXISTING WALL TO BE REMOVED
EXISTING MASONRY WALL TO BE REMOVED
EXISTING CONCRETE WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING GLAZING TO BE REMOVED
PLAN NOTE DESIGNATION
DEMOLITION LEGEND
VESTIBULE
ENTRY
CORRIDOR
PANTRY
PANTRY
PANTRY
KITCHEN
DINING ROOM
DAY ROOM
WATCH ALCOVE
TOILET
TOILET
CAPTAIN OFFICE
CORRIDOR
WATCH ROOM
STORAGE
EXERCISE
CLOSET
T'COM. CLOSET
MECHANICAL/ELECTRICAL
STAIR
STAGING
STAIR
AD101
FITNESS
EXISTING BULKHEAD
AD101
NOTE: ALTERNATE 1 - UPGRADE EXISTING FIRST
FLOOR LAUNDRY INTO NEW DECONTAMINATION
ROOM AS INDICATED ON SHEET A403, IF ALTERNATE
1 IS NOT ACCEPTED, PROVIDE NEW DOOR ASSEMBLY
AS CALLED OUT IN DOOR SCHEDULE IN NEW
PARTITION AT BASE OF FIRE POLE.
LAUNDRY
LAUNDRY
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica
Group, Inc. It is intended solely for use by The Etica
Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica
Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
/2
/2
:2 :1
P
M A u to d e s k D o c s
/2
C a rm e l F ir e
S ta tio n
/2
C a rm e l F ir e
S ta tio n
.r vt
AD101
250060
ERS TLG
FIRST FLOOR
DEMOLITION
PLANS
R e n o va tio n o f S ta tio n
W th S t.
C a rm e
C ity o f
C a rm e l
O n e C iv ic
S q u a re
C a rm e
8/14/2026
KEY NOTES - DEMOLITION
NO. DESCRIPTION
1. REMOVE EXISTING DOOR ASSEMBLY IN ITS ENTIRETY INCLUDING FRAME AND HARDWARE AND STORE
FOR REUSE
2. REMOVE EXISTING PARTITION IN ITS ENTIRETY
3. EXPAND EXISTING GWB WRAPPED OPENING TO CLOSET WALL. REFRAME HEADER FOR LARGER OPENING.
HEAD HEIGHT TO REMAIN THE SAME.
4. DEMOLISH EXISTING CASEWORK AND LOW PARTITIONS.
5. REMOVE EXISTING LOCKERS.
6. REMOVE EXISTING BENCH
7. DEMOLISH EXISTING COUNTERTOP, SINKS, CABINET, AND MIRROR
8. REMOVE EXISTING FLOOR FINISH. PREP SURFACE FOR NEW FLOOR FINISH
9. NOT USED
10. EXPAND EXISTING DOOR FRAMING TO ACCOMODATE LARGER DOOR, SEE DOOR SCHEDULE
11. REMOVE EXISTING DOOR ASSEMBLY IN IT'S ENTIRETY
12. CUT SLAB TO TIE NEW TRENCH DRAIN INTO EXISTING FLOOR DRAIN SYSTEM, SEE PLUMING DRAWINGS
13. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL ON ONE SIDE AS INDICATED BY DASHED LINE
14. REMOVE EXISTING WALL CABINETS AND SALVAGE FOR RE-USE
15. REMOVE EXISTING BASE CABINETS AND COUNTERTOP
16. REMOVE EXISTING PLUMBING FIXTURE
17. REMOVE EXISTING WASHER AND DRYER - COORDINATE WITH OWNER
18. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL AS INDICATED BY DASHED LINE
19. REMOVE EXISTING GWB ON UNISEX RESTROOM SIDE OF WALL AS INDICATED BY DASHED LINE
20. REMOVE EXISTING DOOR AND HARDWARE. FRAME CAN REMAIN IN PLACE. PREP EXISTING FRAME FOR
NEW DOOR AND HARDWARE.
G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS
AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO
COMMENCMENT OF WORK.
F. THE CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY
THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED. ANY
QUESTIONS SHALL PROMPTLY REFERRED TO THE ARCHITECT FOR RESOLUTION.
E. CONTRACTOR IS RESPONSIBLE FOR CUTTING AND PATCHING OF FLOORS, WALLS, AND
CEILINGS. PATCH ALL AREAS REQUIRE TO ACCEPT NEW HVAC, PLUMBING, AND
ELECTRICAL WORK. PATCH AND REPAIR TO A FINISHED CONDITION INDICATED IN THE
DRAWINGS OR TO MATCH EXISTING.
D. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING
SURFACES, MATERIALS, AND COMPONENTS TO REMAIN. ANY DAMAGE RESULTING
FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED BY THE CONRACTOR T...
C. WHERE DEMOLITION WORK EXPOSED AND UNFINISHED SURFACE OR CONDITION IN A
SURFACE TO REMAIN EXPOSED, THE CONTRACTOR SHALL PATCH, REPAIR, AND
PREPARE SUCH SURFACE OR CONDITION AS REQUIRED TO PROPERLY RECEIVE NEW
FINISHES AND TO MATCH THE EXISTING ADJACENT SURFACE.
B. ALL EXISTING SURFACE LOCATED ADJACENT TO DEMOLITION WORK AND SCHEDULE
TO REMAIN EXPOSED AFTER COMPLETION OF NEW CONSTRUCTION SHALL BE
REPAIRED AND PATCHED AS REQUIRED TO MATCH EXISTING.
A. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION WORK
AND SCHEDULED TO RECEIVE NEW CONSTRUCTION, SHALL BE REPAIRED AND
PATCHED AS REQUIRED TO CLEANLY AND SOUNDLY RECEIVE NEW WORK.
GENERAL DEMOLITION PLAN NOTES
AD101 1/8" = 1'-0" REF:3/A403
FIRST FLOOR DEMOLITION PLAN 1
AD101 1/8" = 1'-0" REF:3/A403
FIRST FLOOR RCP DEMOLITION 2
KEY NOTES - RCP DEMOLITION
NO. DESCRIPTION
1. REMOVE EXISTING CEILING AND FIXTURES AND PREP FOR NEW WORK. SALVAGE EXISTING CEILING TILES
FOR POSSIBLE REUSE. COORDINATE WITH OWNER
3. RECONFIGURE EXISTING BULKHEAD TO ACCOMODATE NEW WORK
AD101 1/2" = 1'-0" REF:1/AD101
FIRST FLOOR DEMOLITION PLAN - DECONTAMINATION 3
AD101 1/2" = 1'-0" REF:2/AD101
RCP DEMOLITION - DECONTAMINATION 4
DN DN
EXISTING ITEM TO REMAIN
EXISTING WALL TO REMAIN
EXISTING DOOR & FRAME TO REMAIN
EXISTING WALL TO BE REMOVED
EXISTING MASONRY WALL TO BE REMOVED
EXISTING CONCRETE WALL TO BE REMOVED
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING GLAZING TO BE REMOVED
PLAN NOTE DESIGNATION
DEMOLITION LEGEND
88 88
4 4
1 1
AD102 1/8" = 1'-0" REF:2/A401
SECOND FLOOR DEMOLITION 2
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
AD102
250060
ERS TLG
SECOND FLOOR
DEMOLITION
PLANS
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
KEY NOTES - DEMOLITION
NO. DESCRIPTION
1. REMOVE EXISTING DOOR ASSEMBLY IN ITS ENTIRETY INCLUDING FRAME AND HARDWARE AND STORE
FOR REUSE
2. REMOVE EXISTING PARTITION IN ITS ENTIRETY
3. EXPAND EXISTING GWB WRAPPED OPENING TO CLOSET WALL. REFRAME HEADER FOR LARGER OPENING.
HEAD HEIGHT TO REMAIN THE SAME.
4. DEMOLISH EXISTING CASEWORK AND LOW PARTITIONS.
5. REMOVE EXISTING LOCKERS.
6. REMOVE EXISTING BENCH
7. DEMOLISH EXISTING COUNTERTOP, SINKS, CABINET, AND MIRROR
8. REMOVE EXISTING FLOOR FINISH. PREP SURFACE FOR NEW FLOOR FINISH
9. NOT USED
10. EXPAND EXISTING DOOR FRAMING TO ACCOMODATE LARGER DOOR, SEE DOOR SCHEDULE
11. REMOVE EXISTING DOOR ASSEMBLY IN IT'S ENTIRETY
12. CUT SLAB TO TIE NEW TRENCH DRAIN INTO EXISTING FLOOR DRAIN SYSTEM, SEE PLUMING DRAWINGS
13. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL ON ONE SIDE AS INDICATED BY DASHED LINE
14. REMOVE EXISTING WALL CABINETS AND SALVAGE FOR RE-USE
15. REMOVE EXISTING BASE CABINETS AND COUNTERTOP
16. REMOVE EXISTING PLUMBING FIXTURE
17. REMOVE EXISTING WASHER AND DRYER - COORDINATE WITH OWNER
18. REMOVE EXISTING GWB ON LAUNDRY ROOM SIDE OF WALL AS INDICATED BY DASHED LINE
19. REMOVE EXISTING GWB ON UNISEX RESTROOM SIDE OF WALL AS INDICATED BY DASHED LINE
20. REMOVE EXISTING DOOR AND HARDWARE. FRAME CAN REMAIN IN PLACE. PREP EXISTING FRAME FOR
NEW DOOR AND HARDWARE.
G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS
AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO
COMMENCMENT OF WORK.
F. THE CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY
THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED. ANY
QUESTIONS SHALL PROMPTLY REFERRED TO THE ARCHITECT FOR RESOLUTION.
E. CONTRACTOR IS RESPONSIBLE FOR CUTTING AND PATCHING OF FLOORS, WALLS, AND
CEILINGS. PATCH ALL AREAS REQUIRE TO ACCEPT NEW HVAC, PLUMBING, AND
ELECTRICAL WORK. PATCH AND REPAIR TO A FINISHED CONDITION INDICATED IN THE
DRAWINGS OR TO MATCH EXISTING.
D. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING
SURFACES, MATERIALS, AND COMPONENTS TO REMAIN. ANY DAMAGE RESULTING
FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED BY THE CONRACTOR T...
C. WHERE DEMOLITION WORK EXPOSED AND UNFINISHED SURFACE OR CONDITION IN A
SURFACE TO REMAIN EXPOSED, THE CONTRACTOR SHALL PATCH, REPAIR, AND
PREPARE SUCH SURFACE OR CONDITION AS REQUIRED TO PROPERLY RECEIVE NEW
FINISHES AND TO MATCH THE EXISTING ADJACENT SURFACE.
B. ALL EXISTING SURFACE LOCATED ADJACENT TO DEMOLITION WORK AND SCHEDULE
TO REMAIN EXPOSED AFTER COMPLETION OF NEW CONSTRUCTION SHALL BE
REPAIRED AND PATCHED AS REQUIRED TO MATCH EXISTING.
A. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION WORK
AND SCHEDULED TO RECEIVE NEW CONSTRUCTION, SHALL BE REPAIRED AND
PATCHED AS REQUIRED TO CLEANLY AND SOUNDLY RECEIVE NEW WORK.
GENERAL DEMOLITION PLAN NOTES
AD102 1/8" = 1'-0" REF:2/A401
SECOND FLOOR DEMOLITION PLAN 1
KEY NOTES - RCP DEMOLITION
NO. DESCRIPTION
1. REMOVE EXISTING CEILING AND FIXTURES AND PREP FOR NEW WORK. SALVAGE EXISTING CEILING TILES
FOR POSSIBLE REUSE. COORDINATE WITH OWNER
3. RECONFIGURE EXISTING BULKHEAD TO ACCOMODATE NEW WORK
A102
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
STORAGE
UNISEX RR
MOTHER'S ROOM
QUIET ROOM
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
034WOMEN'S LOCKERS
MEN'S RR
BEDROOM
BEDROOM
BEDROOM
NO NEW WORK
MEN'S LOCKERS
A101
STAGING
DECONTAMINATION
FIRE POLE
125b
CAPTAIN OFFICE
FITNESS
CORRIDOR
MECHANICAL/ELECTRICAL
T'COM. CLOSET
121CLOSET
NO NEW WORK
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
A100
250060
ERS TLG
OVERALL PLANS
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
A100 1/8" = 1'-0" REF:2/A401
SECOND FLOOR PLAN 2
A100 1/8" = 1'-0" REF:3/A403
FIRST FLOOR PLAN 1
N
UP
CAPTAIN OFFICE
CORRIDOR
CLOSET
T'COM. CLOSET
MECHANICAL/ELECTRICAL
STAGING
A403
AL
IG
N
FIRE POLE
125b
DECONTAMINATION
113 FITNESS
S3A-4
S3E-2a
S3E-2a
S3B-2
DI
M . P
ER
M
FR
. I
NS
TA
LL
AT
IO
N
'-1 /2
2'-9"
1'-9 1/8"
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
A101
250060
ERS TLG
FIRST FLOOR
PLAN
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
KEY NOTES - FLOOR PLAN
NO. DESCRIPTION
1. NOT USED
2. NEW WALL TO ALIGN WITH EDGE OF EXISTING GWB CEILING
3. NEW VENTED LOCKER WITH BENCH, 24" W X 24" D X 84" TALL
4. SHOWER WITH HOSE BIB
5. NEW DOOR AT FIRE POLE IS PART OF BASE BID. REUSE EXISTING DOOR AS PART OF
ALTERNATE 1
6. EXISTING FIRE POLE OPENING
7. FUTURE EXTRACTOR, PROVIDE ROUGH-INS ONLY
8. EXTEND LOCKER FRONT, DRAWER BASE FRONT, AND BENCH AROUND CORNER AND TO
END WALL AS SHOWN TO CREATE CONTINUOUS INSTALLATION
9. INFILL WALL WHERE DOOR IS REMOVED TO MATCH SURROUNDING CONSTRUCTION
10. INSTALL MOISTURE RESISTANT GWB, FULL HEIGHT OF STUDS, ON DECONTAMINATION
SIDE OF EXISTING WALLS AND BULKHEADS. INSULATE AND SEAL WALLS FOR ACOUSTIC
RATING OF 40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.
11. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE, ADD ACOUSTIC
INSULATION AND MOISTURE RESISTANT GWB TO LAUNDRY ROOM SIDE OF WALL, ADD
AN ADDITIONAL LAYER OF GWB TO BUNKROOM SIDE OF WALL, AND SEAL TO MEET
ACOUSTIC RATING OF 50 STC MIN. DEPENDING ON EXISTING WALL CONSTRUCTION.
12. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE.
13. INSTALL MOISTURE RESISTANT GWB ON UNISEX RESTROOM SIDE OF WALL, EXTEND TO
UNDERSIDE OF GWB LID ABOVE. INSULATE AND SEAL WALLS FOR ACOUSTIC RATING OF
40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.
14. CORNER GUARD
15. 18" DEEP ADJUSTABLE SHELVES ON STANDARDS, PROVIDE FIVE SHELVES
16. FLOOR FINISH MATERIALTRANSITION LINE - SEE SHEET A601 FOR DETAILS
17. PROVIDE HOLLOW METAL FRAME CASED OPENING
H. ALL INTERIOR WALLS ARE S3A-2a UNLESS NOTED OTHERWISE ON THE FLOOR PLANS.
G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS
AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO
COMMENCMENT OF WORK.
F. INSTALL BLOCKING INSIDE WALL FOR INSTALLATION OF WALL HUNG EQUIPMENT
INCLUDING OWNER PROVIDED EQUIPMENT. COORDINATION LOCATION OF BLOCKING
WITH ARCHITECT PRIOR TO INSTALLATION.
E. MANUFACTURERS LISTED IN THE CONSTRUCTION DOCUMENTS ARE FOR
"BASIS-OF-DESIGN". SUBSTITUTIONS SHALL MEET OR EXCEED THE PERFORMANCE
REQUIREMENTS AND ASTM STANDARDS LISTED IN THE SPECIFICATIONS TO BE
CONSIDERED AN APPROVED EQUAL BY THE OWNER AND ARCHITECT OF RECORD.
D. ALL GYPSUM WALL BOARD SHALL BE 5/8" TYPE 'X' UNLESS NOTED OTHERWISE.
PROVIDE LEVEL 4 FINISH UNLESS NOTED OTHERWISE.
C. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.
B. ALL DOOR FRAMES ARE LOCATED 4-INCHES FROM ADJACENT WALL UNLESS NOTED
OTHERWISE.
A. ALL DIMENSIONS ARE SHOWN TO FACE OF STUD, MASONRY, OR COLUMN
CENTERLINES UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS CLEAR
("CLR") INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH.
GENERAL FLOOR PLAN NOTES
I. INSTALL CORNER GUARDS ON ALL OUTSIDE CORNERS AS NOTED ON PLANS
H. PROVIDE SEALANT SAMPLES FOR SELECTION BY THE ETICA GROUP FOR ALL INTERIOR
SEALANT APPLICATIONS. CLEAR SILCONE SEALANTS ARE NOT ACCEPTABLE.
G. REFER TO INTERIOR ELEVATIONS & SECTIONS WHERE PROVIDED FOR ADDITIONAL
FINISH INFORMATION. NOTE ANY DISCREPANCIES TO THE ETICA GROUP.
F. SUBMIT SAMPLES OF MILLWORK, CASWORK AND WOOD DOORS (STAINED OR PAINTED)
TO ETICA GROUP FOR REVIEW AND APPROVAL PRIOR TO FINISHING OF MATERIALS.
E. FOR CHANGES IN FLOOR MATERIAL, PROVIDE TRANSITION STRIPS BETWEEN FLOORING
OF DIFFERING MATERIALS. WHERE MATERIAL CHANGES AT A DOOR OPENING, FINISH
CHANGE SHOULD OCCUR CENTERED UNDER THE DOOR.
D. ALL AREAS TO RECEIVE PAINT ARE TO RECEIVED PRIMER COAT AND TWO COATS OF
FINISH.
C. FOR NEW ELECTRICAL, THERMOSTATS AND OTHER DEVICES, COORDINATION COLOR
SELECTION WITH ETICA GROUP PRIOR TO INSTALLATION.
B. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CONSTRUCTION AS INDICATED.
WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0". VERIFY
FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK
WHETHER OR NOT INDICATED ON DRAWINGS.
A. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE 2014
INDIANA BUILDING CODE FOR CLASS C FIRE RATINGS.
GENERAL FINISH NOTES
A101 1/4" = 1'-0" REF:1/A100
LEVEL 1 FLOOR PLAN 1
N
A501
8' -1 1/ 4"
8' -1 3/ 4"
11'-4 1/4" 5'-4 7/8" 7'-3 3/4" 2'-10" 2'-10" +/-6'-11 1/2"
2' -1 0"
5' -4 /8
'-4 /4
5'-4 7/8" 11'-0 5/8"
94 SF
BEDROOM
94 SF
BEDROOM
124 SF
BEDROOM
98 SF
BEDROOM
94 SF
BEDROOM
94 SF
BEDROOM
94 SF
BEDROOM
94 SF
BEDROOM
13 SF
STORAGE
73 SF
UNISEX RR
49 SF
MOTHER'S ROOM
330 SF
QUIET ROOM
81 SF
MECHANICAL
03146 SF
VESTIBULE
474 SF
CORRIDOR
43 SF
VESTIBULE
172 SF
WOMEN'S LOCKERS
A401
A401
A401
A401
A402
008007006
005004
98 SF
BEDROOM
124 SF
BEDROOM
94 SF
BEDROOM
S3B-2
S3B-2
S3B-2a
S3B-2
4' -1 /4
4' -1 /2
6"6"
S3A-1S3A-1 15
S3A-1
S3B-2a
S3E-2a
S3E-2a 16 16
8' -1 3/ 4"
8' -1 1/ 4"
S3B1
3/ 4"
3/ 4"
P-2
P-2
P-2
P-2
4'-1 1/4" 3 5/8" 8'-4" 3 5/8" EQ.
5'-0" CLR.
EQ. 3 5/8" EQ. 3 5/8" 8'-4" 3 5/8" 4'-1 1/4"
DI
M . P
ER
M
FR
. I
NS
TA
LL
AT
IO
N
'-1 /2
3'-0" 10'-2 7/8" 3 5/8"
WOMEN'S RR
WOMEN'S SHOWER
MEN'S RR
MEN'S SHOWER
JANITOR'S
MEN'S LOCKERS
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
A102
250060
ERS TLG
SECOND FLOOR
PLAN
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
A102 1/4" = 1'-0"
SECOND FLOOR PLAN 1
KEY NOTES - FLOOR PLAN
NO. DESCRIPTION
1. NOT USED
2. NEW WALL TO ALIGN WITH EDGE OF EXISTING GWB CEILING
3. NEW VENTED LOCKER WITH BENCH, 24" W X 24" D X 84" TALL
4. SHOWER WITH HOSE BIB
5. NEW DOOR AT FIRE POLE IS PART OF BASE BID. REUSE EXISTING DOOR AS PART OF
ALTERNATE 1
6. EXISTING FIRE POLE OPENING
7. FUTURE EXTRACTOR, PROVIDE ROUGH-INS ONLY
8. EXTEND LOCKER FRONT, DRAWER BASE FRONT, AND BENCH AROUND CORNER AND TO
END WALL AS SHOWN TO CREATE CONTINUOUS INSTALLATION
9. INFILL WALL WHERE DOOR IS REMOVED TO MATCH SURROUNDING CONSTRUCTION
10. INSTALL MOISTURE RESISTANT GWB, FULL HEIGHT OF STUDS, ON DECONTAMINATION
SIDE OF EXISTING WALLS AND BULKHEADS. INSULATE AND SEAL WALLS FOR ACOUSTIC
RATING OF 40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.
11. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE, ADD ACOUSTIC
INSULATION AND MOISTURE RESISTANT GWB TO LAUNDRY ROOM SIDE OF WALL, ADD
AN ADDITIONAL LAYER OF GWB TO BUNKROOM SIDE OF WALL, AND SEAL TO MEET
ACOUSTIC RATING OF 50 STC MIN. DEPENDING ON EXISTING WALL CONSTRUCTION.
12. EXTEND WALL FRAMING AND GWB TO UNDERSIDE OF GWB LID ABOVE.
H. ALL INTERIOR WALLS ARE S3A-2a UNLESS NOTED OTHERWISE ON THE FLOOR PLANS.
G. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS
AND REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO
COMMENCMENT OF WORK.
F. INSTALL BLOCKING INSIDE WALL FOR INSTALLATION OF WALL HUNG EQUIPMENT
INCLUDING OWNER PROVIDED EQUIPMENT. COORDINATION LOCATION OF BLOCKING
WITH ARCHITECT PRIOR TO INSTALLATION.
E. MANUFACTURERS LISTED IN THE CONSTRUCTION DOCUMENTS ARE FOR
"BASIS-OF-DESIGN". SUBSTITUTIONS SHALL MEET OR EXCEED THE PERFORMANCE
REQUIREMENTS AND ASTM STANDARDS LISTED IN THE SPECIFICATIONS TO BE
CONSIDERED AN APPROVED EQUAL BY THE OWNER AND ARCHITECT OF RECORD.
D. ALL GYPSUM WALL BOARD SHALL BE 5/8" TYPE 'X' UNLESS NOTED OTHERWISE.
PROVIDE LEVEL 4 FINISH UNLESS NOTED OTHERWISE.
C. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.
B. ALL DOOR FRAMES ARE LOCATED 4-INCHES FROM ADJACENT WALL UNLESS NOTED
OTHERWISE.
A. ALL DIMENSIONS ARE SHOWN TO FACE OF STUD, MASONRY, OR COLUMN
CENTERLINES UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS CLEAR
("CLR") INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH.
GENERAL FLOOR PLAN NOTES
I. INSTALL CORNER GUARDS ON ALL OUTSIDE CORNERS AS NOTED ON PLANS
H. PROVIDE SEALANT SAMPLES FOR SELECTION BY THE ETICA GROUP FOR ALL INTERIOR
SEALANT APPLICATIONS. CLEAR SILCONE SEALANTS ARE NOT ACCEPTABLE.
G. REFER TO INTERIOR ELEVATIONS & SECTIONS WHERE PROVIDED FOR ADDITIONAL
FINISH INFORMATION. NOTE ANY DISCREPANCIES TO THE ETICA GROUP.
F. SUBMIT SAMPLES OF MILLWORK, CASWORK AND WOOD DOORS (STAINED OR PAINTED)
TO ETICA GROUP FOR REVIEW AND APPROVAL PRIOR TO FINISHING OF MATERIALS.
E. FOR CHANGES IN FLOOR MATERIAL, PROVIDE TRANSITION STRIPS BETWEEN FLOORING
OF DIFFERING MATERIALS. WHERE MATERIAL CHANGES AT A DOOR OPENING, FINISH
CHANGE SHOULD OCCUR CENTERED UNDER THE DOOR.
D. ALL AREAS TO RECEIVE PAINT ARE TO RECEIVED PRIMER COAT AND TWO COATS OF
FINISH.
C. FOR NEW ELECTRICAL, THERMOSTATS AND OTHER DEVICES, COORDINATION COLOR
SELECTION WITH ETICA GROUP PRIOR TO INSTALLATION.
B. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CONSTRUCTION AS INDICATED.
WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0". VERIFY
FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK
WHETHER OR NOT INDICATED ON DRAWINGS.
A. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE 2014
INDIANA BUILDING CODE FOR CLASS C FIRE RATINGS.
GENERAL FINISH NOTES
AL
IG
N
AL
IG
N
AL
IG
N
N
KEY NOTES - FLOOR PLAN
NO. DESCRIPTION
13. INSTALL MOISTURE RESISTANT GWB ON UNISEX RESTROOM SIDE OF WALL, EXTEND TO
UNDERSIDE OF GWB LID ABOVE. INSULATE AND SEAL WALLS FOR ACOUSTIC RATING OF
40 STC MINIMUM DEPENDING ON EXISTING WALL CONSTRUCTION.
14. CORNER GUARD
15. 18" DEEP ADJUSTABLE SHELVES ON STANDARDS, PROVIDE FIVE SHELVES
16. FLOOR FINISH MATERIALTRANSITION LINE - SEE SHEET A601 FOR DETAILS
17. PROVIDE HOLLOW METAL FRAME CASED OPENING
S
SD
SD
NEW DEMO EXISTING TO REMAIN
GYPSUM BOARD
CEILING
CEILING GRID,
SUSPENDED, 2' X 4'
CEILING GRID,
SUSPENDED, 2' X 2'
CEILING GRID,
SUSPENDED, 2' X 4'
CEILING GRID,
SUSPENDED, 2' X 2'
GYPSUM BOARD
CEILING
GYPSUM BOARD
CEILING
CEILING GRID,
SUSPENDED, 2' X 4'
CEILING GRID,
SUSPENDED, 2' X 2'
ACT-12
12'-0" A.F.F.
REFLECTED CEILING PLAN LEGEND
RETURN AIR
DIFFUSER
SUPPLY AIR
DIFFUSER
2 X 2 LIGHT FIXTURE,
EMERGENCY
LINEAR LIGHT
FIXTURE
SPRINKLER HEAD
(VARIES)
EMERGENCY EXIT
LIGHT
2 X 4 LIGHT FIXTURE
CEILING TYPE
CEILING HEIGHT
CAN LIGHT FIXTURE
DIRECTIONAL EXIT
SIGN
2 X 2 LIGHT FIXTURE
SPEAKER
OCCUPANCY
SENSOR
S
SMOKE DETECTORSD
CEILING FAN
A403
CAPTAIN OFFICE
CORRIDOR
CLOSET
T'COM. CLOSET
MECHANICAL/ELECTRICAL
STAGING
FITNESS
FIRE POLE
125b
DECONTAMINATION
ACT-1
9'-0"A.F.F.
ACT-2
9'-0"A.F.F.
ACT-1
9'-0"A.F.F.
ACT-1
8'-0"A.F.F.
GWB
8'-0"A.F.F.
CHECKED BY:DATE ISSUED: DRAWN BY:
PROJECT NUMBER:
PROFESSIONAL SEAL:
DRAWING TITLE:
SHEET NUMBER:
This construction document is the property of The Etica Group, Inc. It is intended solely for use by The Etica Group, Inc., its heirs, and assigns. Modification or reuse of the document without permission from The Etica Group, Inc. is prohibited. Use of this document for any purpose other than that intended by The Etica Group, Inc.
constitutes an impermissible misuse. The Etica group, inc. is not responsible for any damage or injury resulting from misuse of this document. The Etica Group, Inc.
disclaims all warranties, express or implied , relating to the use of this document for any purpose other than that intended by The Etica Group, Inc.
DISCLAIMER:
ISSUED FOR CONSTRUCTION
8/ /2 :3 6:
P M
A ut od es k D oc s:
//2
- C ar m el F ire S ta tio n /2 C ar m el F ire S ta tio n .rv t
A103
250060
ERS TLG
CEILING PLAN -
FIRST
R en ov at io n of S ta tio n
W . 1 th S t.
C ar m el , I N
C ity o f C ar m el
O ne C iv ic S qu ar e
C ar m el , I N
8/14/2026
KEY NOTES - CEILING PLAN
NO. DESCRIPTION
1 NEW GYPSUM BULKHEAD
2 OPEN TO GWB LID ABOVE
H. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED DIFFUSERS, GRILLE TYPES AND
QUANTITIES.
G. REFER TO ELECTRICAL DRAWINGS FOR CEILING-MOUNTED LIGHT FIXTURE TYPES AND
QUANTITIES.
F. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS INDICATED ON THE DRAWINGS AND
REPORT ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER PRIOR TO COMMENCMENT...
E. CEILING HEIGHTS TO MATCH EXISTING UNLESS NOTED OTHERWISE.
D. ALL NEW CEILINGS TO BE 2'X2' ACOUSTIC PANEL CEILING. REFER TO FINISH AND ROOM
SCHEDULES FOR TYPES.
C. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,
SMOKE DETECTORS, SPRINKLER HEADS, OCCUPANCY SENSORS, SPEAKERS, CEILING FANS,
AND EXIT SIGNS UNLESS OTHERWISE NOTED.
B. COORDINATION OF DUCTWORK, PIPING, LIGHTS AND CEILING SUPPORTS ARE THE
RESPONSIBILITY OF THE TRADE CONTRACTORS. CONTRACTORS WILL ACCEPT
RESPONSIBILITY TO RELOCATE ITEMS THAT CONFLICT DUE TO LACK OF COORDINATION.
A. ALL NEW CEILING GRIDS ARE CENTERED IN ROOMS IN EACH DIRECTION UNLESS NOTED
OTHERWISE. NO TILE SHOULD BE LESS THAN 6-INCHES WIDE AT THE EDGES.
GENERAL CEILING PLAN NOTES
A103 1/4" = 1'-0" REF:3/A403
LEVEL 1 CEILING 1
N
S
S
S
S S
S
S S
S
S
S
S
S
S
S S
S
SS
S
S
SD
SD
SD
SD
SD
SD
SD SD
SD
SD SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
NEW DEMO EXISTING TO REMAIN
GYPSUM BOARD
CEILING
CEILING GRID,
SUSPENDED, 2' X 4'
CEILING GRID,
SUSPENDED, 2' X 2'
CEILING GRID,
SUSPENDED, 2' X 4'
CEILING GRID,
SUSPENDED, 2' X 2'
GYPSUM BOARD
CEILING
GYPSUM BOARD
CEILING
CEILING GRID,
SUSPENDED, 2' X 4'
CEILING GRID,
SUSPENDED, 2' X 2'
ACT-12
12'-0" A.F.F.
REFLECTED CEILING PLAN LEGEND
RETURN AIR
DIFFUSER
SUPPLY AIR
DIFFUSER
2 X 2 LIGHT FIXTURE,
EMERGENCY
LINEAR LIGHT
FIXTURE
SPRINKLER HEAD
(VARIES)
EMERGENCY EXIT
LIGHT
2 X 4 LIGHT FIXTURE
CEILING TYPE
CEILING HEIGHT
CAN LIGHT FIXTURE
DIRECTIONAL EXIT
SIGN
2 X 2 LIGHT FIXTURE
SPEAKER
OCCUPANCY
SENSOR
S
SMOKE DETECTORSD
CEILING FAN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
1 1 1
A501
A501
A402
STORAGE
UNISEX RR
MOTHER'S ROOM
QUIET ROOM
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
WOMEN'S LOCKERS
BEDROOM
BEDROOM
BEDROOM
1'-0"
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
GWB
7'-6"A.F.F.
GWB
7'-6"A.F.F.
GWB
7'-6"A.F.F.
G W B
7' -6 "A .F .F
G W B
7' -6 "A .F .F
GWB
7'-6"A.F.F.
ACT-1
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
GWB
7'-10"A.F.F.
ACT-2
8'-0"A.F.F.
ACT-1
8'-0"A.F.F.
A501
Si…