This document outlines a federal construction contract solicitation. The Department of Veterans Affairs is seeking a firm-fixed-price construction contract for Phase 1A Expansion of Ft. Logan National Cemetery in Denver, Colorado. The contractor will provide all labor, materials, and equipment to complete the construction project as defined in the plans, drawings, and specifications for an estimated cost between $20-50 million. This is a 100% set-aside opportunity for Service-Disabled Veteran Owned Small Businesses. The North American Industry Classification System code for this project is 237990 for other heavy and civil engineering construction, with a size standard of $45 million. The pre-proposal site visit is scheduled as detailed in provision 52.236-27 and proposals are due by May 16, 2023 at 3:00 PM Eastern Time, as outlined in the solicitation's "Information for Offerors" section.

View the file

Other files

File Type Posted
S06 - 36C10F23R0013 0001 Amendment -PPI Response.pdf PDF
S06 - DOL Wage Determination CO20230002 04-07-2023.pdf PDF
S06 - Pre-Proposal Conference slides FLNC 4-19.pdf PDF
S06 - Ft. Logan Sign-in 4-19-23.pdf PDF
Bid Docs - Reports - Phase 1 Expansion Geotechnical Report.pdf PDF
S06 - 36C10F23R0013 Pre-Proposal Inquiry Responses.docx DOCX document
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(5 of 5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT3 - 2023 02 10(2 of 2).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (4of5).pdf PDF
S02 FT LOGAN NC PHASE 1A SPECIFICATIONS - 2023 02 21.pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(4 of 5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT2 - 2023 02 10(1 of 2).pdf PDF
S02 - DOL Wage Determination CO20230002 2-24-2023.pdf PDF
S02 Pre-Proposal Inquiry (PPI) Form 36C10F23R0013.docx DOCX document
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (6 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (3of5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT3 - 2023 02 10(1 of 2).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (4 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (5 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (5of5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(1 of 5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(3 of 5).pdf PDF
S02 - VAAR 852.219-75 VA Notice of Limitations on Subcontracting - Certification.pdf PDF
S02 - DOL Wage Determination CO20230009 2-24-2023.pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (3 of 6).pdf PDF
S02 Past Performance Questionnaire 36C10F23R0013.docx DOCX document
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (1of5).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (2 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (1 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT2 - 2023 02 10(2 of 2).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (2of5).pdf PDF
S02 - 36C10F23R0013 - Final - RFP - Ft Logan Phase 1A.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C.P.C.P.C.P.

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

C.P.C.P.C.P.

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

C.P.C.P.C.P.

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

W

CD105

CD107CD108CD109

CD110

CD103

CD117

CD118

CD111

CD115

CD120

CD121

CD102

CD113

CD116

CD104

CD122

CD101

CD112

CD114

CD106

CD123

OKLAHOMA ST

DENVER DR

D E

N V

E R

D R

OMAHA DR

O M

A H

A D

R

LOGAN BLVD

L O

G A

N B

LV

D

K A

N S

A S

S T

W Y

O M

IN

G

S T

MONTANA ST

DENVER DRDENVER DR

MEMORIAL LAKE

COLORADO ST

COLORADO ST

COLORADO ST

S . S

H E

R

ID

A N

B

LV

D

KENYON AVE

S . S

H E

R

ID

A N

B

LV

D

. VETERANS LAKE

OMAHA DR

CONSTRUCTION ACCESS ROAD

U T

A H

S T

R E

E T

PROJECT BOUNDARY

PROJECT

BOUNDARY

PROJECT

BOUNDARY

PROJECT BOUNDARY

PROJECT BOUNDARY

P.I.C.

BUILDING

CD115

CD115

CD119

CD123

COMMITTAL

SHELTER B

COMMITTAL

SHELTER A

COMMITTAL

SHELTER C

COMMITTAL

PARKING C

COMMITTAL B

PARKING

COMMITTAL

A PARKING

WEST GATE

ENTRANCE

MAIN GATE

ENTRANCE

STOCK

PILE

NORTH

OF

OVERALL DEMOLITION PLAN

PLAN INDEX

CFS JDS

CD100

29 165

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

FLNC PH1A

FLNC PH1B

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

BASH

PHASE 1A - ALTERNATE 4 BID DOCUMENTS

02 / 10 / 2023

DENVER DR

SECTION 11 SECTION 9 SECTION 7

SECTION 8 SECTION 5

PINEHURST ESTATES

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

OF

DEMOLITION PLAN

COLUMBARIUM 4 COURTS A & B

ETG RLB

CD107

30 165

NORTH

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

S

S H

E R

ID

A

N B

O U

LE

V

A R

D

DENVER DR

OF

DEMOLITION PLAN

DENVER DRIVE

ETG JDS

CD116

37 165

NORTH

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

BASH02 / 10 / 2023

SECTION V

SECTION U

DENVER DR

DENVER DR

OF

DEMOLITION PLAN

DENVER DRIVE

ETG JDS

CD117

38 165

NORTH

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

PHASE 1B ROAD CONSTRUCTION

RE: CP106

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

OMAHA DR

N

EB

R A

SK

A

S T

EXISTING SOUTH

DETENTION POND

D E

N V

E R

D R

OF

DEMOLITION PLAN

DENVER DRIVE

ETG JDS

CD118

39 165

NORTH

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

DENVER DRIVE

SECTION 5

SECTION 4

SECTION 6

OF

DEMOLITION PLAN

ETG RLB

CD119

40 165

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

NORTH

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

44 OF 165DENVER DRIVE

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

D

EN

V

ER

D R

IV

E

PARKING FOR

COMMITTAL

SHELTER C

SECTION 8

SECTION 5

SECTION 10

SECTION 2

SECTION 9

SECTION 7

SECTION 3

COMMITTAL

SHELTER C

OF

DEMOLITION PLAN

ETG RLB

CD120

41 165

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

N O

R T

H

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

45 OF 165DENVER DRIVE

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

DENVER DRIVE

SECTION 11

SECTION 10

OF

DEMOLITION PLAN

ETG RLB

CD121

42 165

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

NORTH

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

DENVER DRIVE 46 OF 165

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

SECTION 13

SECTION 13

SECTION 13

SECTION 13

OKLAHOMA ST

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

OF

DEMOLITION PLAN

ETG JDS

CD122

43 165

KEYNOTE LEGEND

LEGEND

1-800-922-1987

KEYMAP

CONSTRUCTION NOTES

STREET REHABILITATION

LEGEND

N O

R T

H

DENVER AND OMAHA DRIVE 47 OF 165

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

GRAVEL ACCESS ROAD

MONTANA ST

C.P.C.P.C.P.

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

PROPERTY LINE

ROAD B

ROAD A

R O

A D

B

RO

AD

B

PROJECT

BOUNDARY

PROPERTY LINE

G R

A V

E L

A C

C E

S S

R O

A D

OKLAHOMA ST

DENVER DR

DE

NVE

R

DR

OMAHA DR

O M

A H

A D

R

LOGAN BLVD

L O

G A

N B

LV

D

K A

N S

A S

S T

W Y

O M

IN

G

S T

DENVER DRDENVER DR

UTAH ST

MEMORIAL LAKE

COLORADO ST

COLORADO ST

COLORADO ST

W. KENYON AVE

S . S

H E

R

ID

A N

B

LV

D

VETERANS LAKE

OMAHA DR

U T

A H

S T

R E

E T

COMMITTAL

SHELTER B

COMMITTAL

SHELTER A

COMMITTAL

SHELTER C

QUINCY AVE

LO

W

E

LL

B

LV

D

ADMIN AND

MAINTENANCE

BUILDING

COMMITTAL

PARKING C

COMMITTAL A

PARKING

SHEET CS103 SHEET CS104

SHEET CS105

SHEET CS106

SHEET CS107

SHEET CS108SHEET CS109SHEET CS110

EX DETENTION POND

(SOUTH POND)

WEST GATE

ENTRANCE

MAIN GATE

ENTRANCE

SHEET CS101 SHEET CS102

TEMPORARY MATERIAL

STORAGE YARD

W

P.I.C.

BUILDING

EXISTING

STOCKPILE

NORTH

OF

OVERALL SITE PLAN

ETG RLB

CS100

45 165

1-800-922-1987

LEGEND

KEYMAP

ENGINEER NOTES:

CONSTRUCTION KEYNOTES

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

SECTION 4

SECTION 27

EXISTING

DETENTION POND

(SOUTH POND)

OMAHA DR

N E

B R

A S

K A

S T

G R

A V

E L

A C

C E

S S

R O

A D

SECTION 27

KEYMAP

ENGINEER NOTES:

NORTH

1-800-922-1987

LEGEND

CONSTRUCTION KEYNOTES

OF

SITE PLAN

GRAVEL ROAD ENTRANCE

ETG JDS

CS101

46 165

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

DENVER DR.

COLUMBARIUM

COURT 4C

COLUMBARIUM

COURT 4B

SECTION 11 SECTION 9SECTION

SECTION 10SECTION 1

PINEHURST ESTATES

COLUMBARIUM

COURT 4A

KEYMAP

ENGINEER NOTES:

NORTH

1-800-922-1987

LEGEND

CONSTRUCTION KEYNOTES

OF

SITE PLAN

COLUMBARIUM 4 COURTS A, B, C

ETG JDS

CS108

47 165

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

SECTION 7

109V

SECTION 11 SECTION 9

109T

109U

DENVER DR

SECTION 109

PINEHURST ESTATES

COLUMBARIA 4 / COURT B

COLUMBARIA 4 / COURT A

NORTH

OF

SECTION MARKER PLAN

COLUMBARIUM 4 COURTS A, B

CFS JDS

CS117

48 165

1-800-922-1987

CONSTRUCTION NOTES:

KEYMAP

LEGEND

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 202201 / 31 / 2023

PHASE 1A - ALTERNATE 1B BID DOCUMENTSPHASE 1A - ALTERNATE 4 BID DOCUMENTS

NOTE:

ANY SEAM IN METAL TO BE FLAT SEAM - SEAMS TO BE HORIZONTAL

AND OCCUR BETWEEN LINES OF LETTERING.

ALL LETTERING TO BE PAINTED BLACK

WITH EXCEPTION OF PROJECT TITLE

WHICH IS TO BE BLUE

5"

9" M

AX

1' -0

" M

AX

2" 5"

5"

2"

4' -0

M

IN

3' -0

6"

6' -0

8'-0" of Veterans Affairs

U.S. Department

CENTER TO BE WHITE

SURROUNDING

BORDER TO BLUE

BACKGROUND TO BE

PAINTED WHITE

BORDER MEMBER PAINTED BLACK PAINT BORDER

MEMBER BLACK

ENAMEL

OPTIMA BOLD

STYLE 5" HIGH

LETTERING

2"X4" FRAME AND

BRACES IN SAME

PLANE

METAL FACE

WHITE ENAMEL

2"X4" FRAME

AND BRACE IN

BACK

METAL FACE

STRETCH METAL FACE

TIGHT, TURN OVER FRAME

AND SECURE WITH FLAT

HEAD DEFORMED NAILS.

LETTERING TO BE OPTIMA

BOLD STYLE 1 1/2" HIGH TO

BE CENTERED HORIZONTAL

4"X4" POSTS

PAINTED WHITE

ELEVATION SECTION

ON CENTERLINE

FORT SAM HOUSTON

PHASE 3 EXPANSION &

IMPROVEMENTS

THIS SPACE FOR

CONTRACTOR'S NAME ONE

OR TWO LINES AS REQUIRED

DESIGNED AND SUPERVISED BY:

DEPARTMENT OF VETERANS

AFFAIRS WASHINGTON D.C.

GENERAL CONTRACTOR

TEMPORARY CONSTRUCTION

SIGNS TO BE FIELD LOCATED.

VERIFY LOCATION WITH SOR/COR.

SP24.1

2"

4"

3' -0

VA

R

IE

S 3'

-0

4'-0"

2"

3/

4"

2"

BLUE

BLUE

OUTLINE

WITH

WHITE

INTERIOR

JOINT

BRACING

4"X4" POST

FIN. GRADE

BRACING SEE

CONSTRUCTION

SIGN DETAIL THIS

SHEET

RED

RED

WHITE

BLUE

ELEVATION

WOOD STRIPS

THE LIFE YOU SAVE MAY BE YOUR OWN

TEMPORARY

CONSTRUCTION SIGNS TO

BE FIELD LOCATED. VERIFY

LOCATION WITH SOR/COR.

SP24.04

VISITOR INFORMATION

We welcome you to these hallowed grounds. To preserve the dignity, beauty and serenity of the cemetery, we ask you to observe our cemetery restrictions.

3"

3' -6

9"

2' -6

R

EC

ES

S

AR

EA

3'-0"

ALUMINUM SIGN PANEL WELDED TO

CONTINUOUS SQUARE TUBULAR

FRAME; SEE SPECIFICATIONS FOR

COLOR & FINISH

1- 3/4" HT. TITLE LETTERING &

1- 1/4" HT. BODY LETTERING,

OPTIMA BOLD TYPE FACE, INITIAL

CAP AND LOWER CASE; SEE

SIGNAGE SCHEDULE FOR COPY

CAST STONE MASONRY POST;

RECESS = 2 1/4" X 2'-6" X 3/8" DP (3)

SIDES; NO RECESS ON INSIDE OF

POSTS

4"

VA

R

IE

S

SI

G

N P

AN

EL

2"

Text As Shown

On Details

POST CONNECTION

QTY. (2) PER SIDE

MESSAGE LAYOUT A

4'-0" TO BACK OF

CURB OR WALK, TYP.

FINISHED

GRADE

CAST STONE

MASONRY COLLAR

POST SETTING

MESSAGE LAYOUT B

The following activities are prohibited:

any form of sports or recreation, including, but not limited to jogging, bicycling, skating and picnicking.

Public gathering of a partisan nature.

Littering of grounds.

Cutting, breaking or injuring of trees, shrubs, grass or other plantings

Allowing pets to run loose.

Boisterous actions.

CEMETERY HOURS

Daily 8 am - 5 pm

Memorial Day 8 am - 7 pm

Floral Regulations

Fresh cut flowers may be placed on graves at any time.

Temporary flower containers are available.

Artificial flowers may be placed on graves only during the period of October through March.

Plantings will not be permitted on graves at any times.

Plotted plants will be permitted on graves only during the period of ten days before and ten days after both easter and memorial day.

Floral items will be removed from graves as soon as they become faded and unsightly.

Christmas wreaths or grave blankets are permitted on graves during the Christmas season and will be removed not later than January 20. Grave floral blankets may not be larger than two feet by three feet.

Floral items and other types of decorations will not be secured to headstones and markers.

Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.

During the mowing season, all floral items will be removed from the graves every two weeks.

2 " SEALANT JOINT (TYP.)

PLACEMENT:

1. SIGHT TRIANGLE AT INTERSECTIONS

AND DRIVEWAYS FOR SAFETY

REASONS, SIGNS SHALL NOT BE

PLACED IN THE SIGHT TRIANGLE

(SHADED AREA) WHERE THEY CAN

OBSCURE A DRIVER'S VISION.

2. ENSURE THE LOCATION OF A SIGN

DOES NOT BLOCK A DRIVER’S VISION

OF PEDESTRIANS. NO SIGNS IN THE

SIGHT TRIANGLE APPLIES TO

ROADWAY INTERSECTIONS AS WELL

AS DRIVEWAYS.

3. TRAFFIC REGULATORY SIGNS SUCH

AS STOP, YIELD, STREET, AND

PEDESTRIAN CROSSING ARE AN

EXCEPTION TO THIS RULE.

4. WHEN INSTALLING SIGNS ADJUST

LOCATIONS FOR UTILITIES,

IRRIGATION LINES AND STREET

TREES.

SIGNS SHALL NOT BE INSTALLED IN THIS

AREA EXCEPT TRAFFIC REGULATORY

AND STREET SIGNS

DIRECTIONAL SIGN

BACK OF

CURB (B.O.C.)

BACK OF

CURB (B.O.C.)

BACK OF

CURB (B.O.C.)

SECTION MARKER

TRAFFIC REGULATORY SIGN

STREET SIGN

10'-0"

2' -0

2'

-0

2'-0"

ROADWAY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 ft . s am la c ad fi le s\ _0 sh ee ts

\1

_l

_s ig na ge w ay fin di ng d et ai ls

.d w g ed it:

jfa hr en ka m p sa ve d:

3/

/2

1:

P ub lis he d:

je ss ic a fa hr en ka m pr in te d:

3/

/2

1:

P

M

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15274

FORT SAM HOUSTON

NATIONAL CEMETERY PHASE 3

EXPANSION & IMPROVEMENTS

846CM2045

12-18-2020

1520 HARRY WURZBACH RD., SAN ANTONIO, TX 78209

BID DOCUMENTS

Date: Dwg. of 339

BID DOCUMENTS

GEOTECHNICAL:

TERRACON

6911 BLANCO ROAD

SAN ANTONIO, TX 78216

210-641-2112

MICHAEL GHAZAWI

IRRIGATION:

AQUA

375 HORSETOOTH ROAD

FORT COLLINS, CO 80525

970-372-6104

ROBERT BECCARD

COST ESTIMATING:

CPMI

3265 NORTHWOOD CIR

EAGAN, MN 55121

515-697-1048

BRYAN BERTRAND

LAND SURVEY:

PAPE-DAWSON

2000 NW LOOP 410

SAN ANTONIO, TX 78213

210-326-6141

DAVID CASANOVA

STRUCTURAL/MEP:

IMEG CORP.

14755 PRESTON RD STE 845

DALLAS, TX 75254

972-239-6100

WADE ROSS

LS-501

JFJL

SIGNAGE & WAYFINDING DETAILS 1

SCALE:1

TEMPORARY CONSTRUCTION SIGN: SP24.1 & SP24.04

N.T.S.

SCALE:2

SIGN PLACEMENT

N.T.S. SCALE:3

VISITORS INFORMATION & FLORAL REGULATIONS SIGN: NC-01.01-C2

N.T.S.

TIMES NEW ROMAN

TIMES NEW ROMAN

Fort Logan National Cemetery Phase 1 Expansion and Improvements

TEMPORARY CONSTRUCTION SIGN

Scale: Actual Size1

12/2012 Page 12-3-1

National Cemetery Signs

This section of the VA Signage Design Guide provides guidelines for the types of signs required to properly sign a National Cemetery.

The following Overview illustrates the various types of signs in this section. The individual pages on each sign type provide more specific information and detailed layouts.

National Cemetery Sign Designations Each sign in the program guide has been given a specific sign type number des-ignation. This designation provides a common description that can be referenced when programming a site and ordering signs. The following explains how the sign type designations are derived.

NC - 07.01 A - m1 NC Designates a National Cemetery sign.

07 Two digit numbers identify a particular sign type.

.01 The two digit number following the period identifies a specific sign size within the sign type.

A The letter designates a specific sign configuration, version and/or layout for graphics.

m1 The letter and number designates the post family and style.

c1 denotes concrete family with square insert style c2 denotes concrete family with round insert style m1 denotes metal family with square style m2 denotes metal family with rectangle style

Overview

SIGN CALLOUT

Scale: Actual Size3

12/2012 Page 12-2-3

National Cemetery Signs

Signs with fit issues - Helvetica Bold Condensed

National Cemetery Prefered Typeface - Optima Bold

VA Second Language - Helvetica Regular

VA Building Standard - Helvetica Bold

National Cemetery Prefered Typeface - Times Roman Bold

Design Elements

Planning

Text Line

EQ

1/3" Cap Height

EQ

1.

x x

Position 1 Position 2 Position 3 Position 4 Position 5

Typeface The preferred typefaces for the National Cemetery System are Optima Bold and Times Roman Bold. Helvetica Bold is the standard typeface for the VA sign program and can be used throughout the sign program.

Signs identifying permanent rooms shall be ABA compliant, to accommodate the visually impaired.

ABA compliant signs must have tactile letters in all caps with accompanying Grade 2 Braille.

All non-ABA signs are to maintain an upper and lower case (Initial Caps) format.

National Cemetery projects may use Optima Bold or Times Roman Bold for dimensional letters on entry and columbarium walls.

Arrows Illustrations show the prescribed arrow for use in the sign program.

Arrow Alignment with Text The arrow is always positioned in such a manner that it is centered in relationship to the capital letter that it precedes. The arrow size is one and one half 1 1/2) times the capital letter height.

SIGN TEXT

Scale: Actual Size4

12/2012 Page 12-2-3

National Cemetery Signs

Signs with fit issues - Helvetica Bold Condensed

National Cemetery Prefered Typeface - Optima Bold

VA Second Language - Helvetica Regular

VA Building Standard - Helvetica Bold

National Cemetery Prefered Typeface - Times Roman Bold

Design Elements

Planning

Text Line

EQ

1/3" Cap Height

EQ

1.

x x

Position 1 Position 2 Position 3 Position 4 Position 5

Typeface The preferred typefaces for the National Cemetery System are Optima Bold and Times Roman Bold. Helvetica Bold is the standard typeface for the VA sign program and can be used throughout the sign program.

Signs identifying permanent rooms shall be ABA compliant, to accommodate the visually impaired.

ABA compliant signs must have tactile letters in all caps with accompanying Grade 2 Braille.

All non-ABA signs are to maintain an upper and lower case (Initial Caps) format.

National Cemetery projects may use Optima Bold or Times Roman Bold for dimensional letters on entry and columbarium walls.

Arrows Illustrations show the prescribed arrow for use in the sign program.

Arrow Alignment with Text The arrow is always positioned in such a manner that it is centered in relationship to the capital letter that it precedes. The arrow size is one and one half 1 1/2) times the capital letter height.

ARROW POSITION

Scale: Actual Size6

12/2012 Page 12-2-3

National Cemetery Signs

Signs with fit issues - Helvetica Bold Condensed

National Cemetery Prefered Typeface - Optima Bold

VA Second Language - Helvetica Regular

VA Building Standard - Helvetica Bold

National Cemetery Prefered Typeface - Times Roman Bold

Design Elements

Planning

Text Line

EQ

1/3" Cap Height

EQ

1.

x x

Position 1 Position 2 Position 3 Position 4 Position 5

Typeface The preferred typefaces for the National Cemetery System are Optima Bold and Times Roman Bold. Helvetica Bold is the standard typeface for the VA sign program and can be used throughout the sign program.

Signs identifying permanent rooms shall be ABA compliant, to accommodate the visually impaired.

ABA compliant signs must have tactile letters in all caps with accompanying Grade 2 Braille.

All non-ABA signs are to maintain an upper and lower case (Initial Caps) format.

National Cemetery projects may use Optima Bold or Times Roman Bold for dimensional letters on entry and columbarium walls.

Arrows Illustrations show the prescribed arrow for use in the sign program.

Arrow Alignment with Text The arrow is always positioned in such a manner that it is centered in relationship to the capital letter that it precedes. The arrow size is one and one half 1 1/2) times the capital letter height.

ARROW ALIGNMENT

Scale: Actual Size7

12/2012 Page 12-2-3

National Cemetery Signs

Signs with fit issues - Helvetica Bold Condensed

National Cemetery Prefered Typeface - Optima Bold

VA Second Language - Helvetica Regular

VA Building Standard - Helvetica Bold

National Cemetery Prefered Typeface - Times Roman Bold

Design Elements

Planning

Text Line

EQ

1/3" Cap Height

EQ

1.

x x

Position 1 Position 2 Position 3 Position 4 Position 5

Typeface The preferred typefaces for the National Cemetery System are Optima Bold and Times Roman Bold. Helvetica Bold is the standard typeface for the VA sign program and can be used throughout the sign program.

Signs identifying permanent rooms shall be ABA compliant, to accommodate the visually impaired.

ABA compliant signs must have tactile letters in all caps with accompanying Grade 2 Braille.

All non-ABA signs are to maintain an upper and lower case (Initial Caps) format.

National Cemetery projects may use Optima Bold or Times Roman Bold for dimensional letters on entry and columbarium walls.

Arrows Illustrations show the prescribed arrow for use in the sign program.

Arrow Alignment with Text The arrow is always positioned in such a manner that it is centered in relationship to the capital letter that it precedes. The arrow size is one and one half 1 1/2) times the capital letter height.

Font Text Standard Scale: Actual Size5

BID DOCUMENTS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting / Chalona Studios Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1 DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Roderick Grier (480)-842-1520

Sign Details 1

01/14/2022 MWC MWC

CS201

OF 394095

NOTE:

ANY SEAM IN METAL TO BE FLAT SEAM - SEAMS TO BE HORIZONTAL

AND OCCUR BETWEEN LINES OF LETTERING.

ALL LETTERING TO BE PAINTED BLACK

WITH EXCEPTION OF PROJECT TITLE

WHICH IS TO BE BLUE

9" M

AX

1' -0

" M

AX

2" 5"

5"

2"

4' -0

M

IN

3' -0

6"

6' -0

8'-0" of Veterans Affairs

U.S. Department

CENTER TO BE WHITE

SURROUNDING

BORDER TO BLUE

BACKGROUND TO BE

PAINTED WHITE

BORDER MEMBER PAINTED BLACK PAINT BORDER

MEMBER BLACK

ENAMEL

OPTIMA BOLD

STYLE 5" HIGH

LETTERING

2"X4" FRAME AND

BRACES IN SAME

PLANE

METAL FACE

WHITE ENAMEL

2"X4" FRAME

AND BRACE IN

BACK

METAL FACE

STRETCH METAL FACE

TIGHT, TURN OVER FRAME

AND SECURE WITH FLAT

HEAD DEFORMED NAILS.

LETTERING TO BE OPTIMA

BOLD STYLE 1 1/2" HIGH TO

BE CENTERED HORIZONTAL

4"X4" POSTS

PAINTED WHITE

ELEVATION SECTION

ON CENTERLINE

FORT SAM HOUSTON

PHASE 3 EXPANSION &

IMPROVEMENTS

THIS SPACE FOR

CONTRACTOR'S NAME ONE

OR TWO LINES AS REQUIRED

DESIGNED AND SUPERVISED BY:

DEPARTMENT OF VETERANS

AFFAIRS WASHINGTON D.C.

GENERAL CONTRACTOR

TEMPORARY CONSTRUCTION

SIGNS TO BE FIELD LOCATED.

VERIFY LOCATION WITH SOR/COR.

SP24.1

2"

3' -0

VA

R

IE

S 3'

-0

4'-0"

2"

3/

4"

2"

BLUE

BLUE

OUTLINE

WITH

WHITE

INTERIOR

JOINT

BRACING

4"X4" POST

FIN. GRADE

BRACING SEE

CONSTRUCTION

SIGN DETAIL THIS

SHEET

RED

RED

WHITE

BLUE

ELEVATION

WOOD STRIPS

THE LIFE YOU SAVE MAY BE YOUR OWN

TEMPORARY

CONSTRUCTION SIGNS TO

BE FIELD LOCATED. VERIFY

LOCATION WITH SOR/COR.

SP24.04

VISITOR INFORMATION

We welcome you to these hallowed grounds. To preserve the dignity, beauty and serenity of the cemetery, we ask you to observe our cemetery restrictions.

3"

3' -6

9"

2' -6

R

EC

ES

S

AR

EA

3'-0"

ALUMINUM SIGN PANEL WELDED TO

CONTINUOUS SQUARE TUBULAR

FRAME; SEE SPECIFICATIONS FOR

COLOR & FINISH

1- 3/4" HT. TITLE LETTERING &

1- 1/4" HT. BODY LETTERING,

OPTIMA BOLD TYPE FACE, INITIAL

CAP AND LOWER CASE; SEE

SIGNAGE SCHEDULE FOR COPY

CAST STONE MASONRY POST;

RECESS = 2 1/4" X 2'-6" X 3/8" DP (3)

SIDES; NO RECESS ON INSIDE OF

POSTS

4"

VA

R

IE

S

SI

G

N P

AN

EL

2"

Text As Shown

On Details

POST CONNECTION

QTY. (2) PER SIDE

MESSAGE LAYOUT A

4'-0" TO BACK OF

CURB OR WALK, TYP.

FINISHED

GRADE

CAST STONE

MASONRY COLLAR

POST SETTING

MESSAGE LAYOUT B

The following activities are prohibited:

any form of sports or recreation, including, but not limited to jogging, bicycling, skating and picnicking.

Public gathering of a partisan nature.

Littering of grounds.

Cutting, breaking or injuring of trees, shrubs, grass or other plantings

Allowing pets to run loose.

Boisterous actions.

CEMETERY HOURS

Daily 8 am - 5 pm

Memorial Day 8 am - 7 pm

Floral Regulations

Fresh cut flowers may be placed on graves at any time.

Temporary flower containers are available.

Artificial flowers may be placed on graves only during the period of October through March.

Plantings will not be permitted on graves at any times.

Plotted plants will be permitted on graves only during the period of ten days before and ten days after both easter and memorial day.

Floral items will be removed from graves as soon as they become faded and unsightly.

Christmas wreaths or grave blankets are permitted on graves during the Christmas season and will be removed not later than January 20. Grave floral blankets may not be larger than two feet by three feet.

Floral items and other types of decorations will not be secured to headstones and markers.

Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.

During the mowing season, all floral items will be removed from the graves every two weeks.

2 " SEALANT JOINT (TYP.)

PLACEMENT:

1. SIGHT TRIANGLE AT INTERSECTIONS

AND DRIVEWAYS FOR SAFETY

REASONS, SIGNS SHALL NOT BE

PLACED IN THE SIGHT TRIANGLE

(SHADED AREA) WHERE THEY CAN

OBSCURE A DRIVER'S VISION.

2. ENSURE THE LOCATION OF A SIGN

DOES NOT BLOCK A DRIVER’S VISION

OF PEDESTRIANS. NO SIGNS IN THE

SIGHT TRIANGLE APPLIES TO

ROADWAY INTERSECTIONS AS WELL

AS DRIVEWAYS.

3. TRAFFIC REGULATORY SIGNS SUCH

AS STOP, YIELD, STREET, AND

PEDESTRIAN CROSSING ARE AN

EXCEPTION TO THIS RULE.

4. WHEN INSTALLING SIGNS ADJUST

LOCATIONS FOR UTILITIES,

IRRIGATION LINES AND STREET

TREES.

SIGNS SHALL NOT BE INSTALLED IN THIS

AREA EXCEPT TRAFFIC REGULATORY

AND STREET SIGNS

DIRECTIONAL SIGN

BACK OF

CURB (B.O.C.)

BACK OF

CURB (B.O.C.)

BACK OF

CURB (B.O.C.)

SECTION MARKER

TRAFFIC REGULATORY SIGN

STREET SIGN

10'-0"

2' -0

2'

-0

2'-0"

ROADWAY

Project Num

Building Num

Drawing Num

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Fi le

P at h:

y

:\1

\1 ft . s am la c ad fi le s\ _0 sh ee ts

\1

_l

_s ig na ge w ay fin di ng d et ai ls

.d w g ed it:

jfa hr en ka m sa ve d:

3/

/2

1:

P ub lis he d:

je ss ic a fa hr en ka m pr in te d:

3/

/2

1:

P

M

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15274

FORT SAM HOUSTON

NATIONAL CEMETERY PHASE 3

EXPANSION & IMPROVEMENTS

846C

12-18-2020

1520 HARRY WURZBACH RD., SAN ANTONIO, TX 78209

BID DOCUMENTS

Date: Dwg.

BID DOCU

GEOTECHNICAL:

TERRACON

6911 BLANCO ROAD

SAN ANTONIO, TX 78216

210-641-2112

MICHAEL GHAZAWI

IRRIGATION:

AQUA

375 HORSETOOTH ROAD

FORT COLLINS, CO 80525

970-372-6104

ROBERT BECCARD

COST ESTIMATING:

CPMI

3265 NORTHWOOD CIR

EAGAN, MN 55121

515-697-1048

BRYAN BERTRAND

LAND SURVEY:

PAPE-DAWSON

2000 NW LOOP 410

SAN ANTONIO, TX 78213

210-326-6141

DAVID CASANOVA

STRUCTURAL/MEP:

IMEG CORP.

14755 PRESTON RD STE 845

DALLAS, TX 75254

972-239-6100

WADE ROSS

LS

JFJL

SIGNAGE & WAYFINDING DETAILS 1

SCALE:1

TEMPORARY CONSTRUCTION SIGN: SP24.1 & SP24.04

N.T.S.

SCALE:2

SIGN PLACEMENT

N.T.S. SCALE:3

VISITORS INFORMATION & FLORAL REGULATIONS SIGN: NC-01.01-C2

N.T.S.

SIGN PLACEMENT

Scale: Actual Size2

12/2012 Page 12-6-5

National Cemetery SignsInstallation

Detail 4 Bronze VA Seal

Size size 609 mm (2') diameter

Description and Use Identifies National Cemetery as a US Government Facility

Sign Components Used with dimensional or Incised letters

Material The plaque shall be cast of a lead free tin bronze, such as C90300 (Navy “G” Bronze) or similar alloy approved by VA.

Bas relief casting based on VA Drawing, shall be of uniform quality and condition, free from injurious blow holes and porosity, cracks and other defects and not warped or distorted, well finished, free from burrs, sharp edges, scratches and defects that may affect appearance or service ability. Casting shall not be repaired, plugged, welded or burned. Finish to be detailed, hand chased for true alignment, filed, belt polished, sides ground smooth, raised surfaces and borders to be polished and buffed to a bright satin finish, background textures to be reverse medium pebble background, fine pebble background, moss as cast. Bronze to be chemically oxidized to a statuary medium color and finish with one coat of clear protective exterior metal lacquer. Fasteners to be corrosion resistant metal compatible with material or casting

1. SEALS LOCATION SHOULD BE TAKEN

FROM CONTRACT DRAWINGS.

2. 2’-0” DIA.

UNLESS OTHERWISE DETERMINED

3. MATERIAL IS CAST BRONZE.

4. DETAIL OF ANCHORAGE MUST BE PROVIDED

BY A/E FOR ANCHORAGE IN ANY MATERIAL

OTHER THAN SOLID MASONRY OR CONCRETE.Front

ELEVATION

DRILL (3) - 1 1/2” [38mm]

ROUND HOLES. MOUNT SEAL ON

SOLID MASONRY OR CONCRETE.

ANCHOR WITH NON-SHRINK MORTAR.

GENERAL NOTES:

3/8” [10mm] THREADED

BRONZE STUDS, SCREW

INTO SOLID METAL PORTION

AT BACK OF SEAL.

FIN. WALL

CONCRETE OR

SOLID

MASONRY

EDGE OF

SEAL

RAISED

LETTERS

SECTION @ FASTENER

ANCHOR

BOLTS

Back

ELEVATION

BRONZE PLAQUE AND NICHE COLUMN MARKERS

Scale: 1.333X8

SEE SHEETS CS501-505 FOR SIGN AND PLAQUE LOCATIONS AND NUMBERING FOR

THE COLUMBARIUMS AND NICHES.

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

8" 1

8" 8" 5

8"1"1"

2"

3/ 8"

R

EC

ES

S, T

YP

AL

L

SI

D

ES

71 2"

(3) #3 EQUALLY

SPACED REBAR

CAST STONE

MASONRY POST;

LIGHT SANDBLAST

FINISH

NOTE:

SEE INDIVIDUAL SIGN TYPE

DETAILS FOR 3/8" RECESS

HEIGHT AND LOCATION ON

OVERALL POST

2"

1" C

AH

M

FE

R

, T

YP

(A

LL

E

D G

ES

71 2"

8"

3/8" RECESS (BELOW);

ALL SIDES

CAST STONE MASONRY

POST; LIGHT SANDBLAST

FINISH

2"

1"

2"

CAST STONE MASONRY

POST WITH 1"

CHAMFER ON ALL

SIDES & TOP; LIGHT

SANDBLAST FINISH

SECTION PLAN VIEW

TOP ELEVATION

2"

8" 1

8" 8" 5

8" 1"1"

2"

3/ 8"

R

EC

ES

S, T

YP

(3

) S

ID

ES

51 2"

(3) #3

EQUALLY

SPACED

REBAR

CAST STONE

MASONRY

POST; LIGHT

SANDBLAST

FINISH

8"

1" C

AH

M

FE

R

, T

YP

(A

LL

E

D G

ES

51 2"

2"

3/8" RECESS

(BELOW);

(3) SIDES

CAST STONE

MASONRY

POST; LIGHT

SANDBLAST

FINISH

SECTION PLAN VIEW

TOP ELEVATION

NOTE:

SEE SIGN TYPE B DETAILS

FOR 3/8" RECESS HEIGHT

AND LOCATION ON

OVERALL POST

A, D, & E

SIGN TYPE

SCALE:2

SQUARE POST

N.T.S.

SIGN POST COLLAR

Scale: Actual Size3

PLAN VIEW

A. ONE TEXT LINE ELEVATION

2 SIGN PANELS

BACK TO BACK

SUBGRADE

F1 A-506

DOMED TOP

3' -0

NOTE:

1. SIGN TYPE: NC-04.01-C1

2. SEE NATIONAL CEMETERY SIGN MANUAL, PAGE 12-2-4 , FOR NCA SPECIFIED PANEL COLORS.

3. PROVIDE BLANK BACK PANEL

2"

4"

4'-10"

3'-0"

2"

5'-0"

4'-10"

PLAN VIEW

ELEVATION

EXISTING METAL POST

NEW SIGN PANEL

EXISTING METAL POST

SIGN PANEL

EXISTING POWDER

COATED ALUMINUM

CHANNEL

1"

1"

EXISTING POWDER

COATED ALUMINUM

POST CAP

SUBGRADE

EXISTING

FOUNDATION AND

MOW STRIP

1. 5,000 PSI ARCH. PRECAST CONC. POST 5 1/2" X 5 1/2" X 4'-10" W/ 1" CHAMFER @ ALL EXPOSED CORNERS &

3/8" RECESS AREA (3 SIDES); FINISH TO MATCH EXISTING.

2. 1" CHAMFERED EDGE AT TOP OF POST.

3. STAINLESS STEEL TAMPER-PROOF SCREWS. 1/4" X 2" SCREWS @ 5" O.C.

4. POWDER COATED ALUMINUM. ALUMINUM SHALL MATCH SIGN FRAME.

5. POWDER COATED ALUMINUM SIGN FRAME.

6. SIGN LETTERING.

7. CONCRETE MOW COLLAR. SEE SPECIFICATIONS.

A. SEE DETAIL F1/A-506 FOR REINFORCEMENT.

Columbarium D

ELEVATION ELEVATION

NOTE:

1. SIGN TYPE: NC-02.01-C1

2. SEE NATIONAL CEMETERY SIGN MANUAL, PAGE 12-2-4 , FOR NCA SPECIFIED PANEL COLORS.

3. PROVIDE BLANK BACK PANEL

4. GRAPHICS TO BE PROVIDED BY THE VA.

Fort Sill National Cemetery

YOU ARE

HERE

A

COLUMBARIUM PLAZA

B

D

COMMITTAL SHELTER #2

COMMITTAL SHELTER #1

ADMINISTRATION BUILDING

& MAINTENANCE COMPLEX

RESTROOMS

GRAVESITE LOCATOR

U.S. FLAG

MEMORIAL PATH

ASSEMBLY AREA

A

B

C

21 4 5

SINGLE LINE SIGN DETAIL

Scale: 2X2

BID DOCUMENTS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting / Chalona Studios Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1 DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Roderick Grier (480)-842-1520

Sign Details 2

01/14/2022 MWC MWC

CS202

OF 3949796

MESSAGE TEXT

TEXT HEIGHT

2.5"

TEXT = TIMES

NEW ROMAN

SINGLE POST INFORMATION SIGN

Scale: 2" = 1'-0"1

1" 5/8"

4"4 1/4" 7 1/2"

7 1/2" 3/8"

4 5/8" 5 1/2"

1"

7 1/2"

7 1/2"

5 1/2"

3/4"

3'-3"

10 7/8"

2 1/4"

(3) #3 Equally Spaced Rebar.

Rebar to be continous vertically, and held 2" short of top and bottom of concrete post.

2'-6"

10 3/4"

3 1/8" 1 1/8"

R 1 1/2"

1"

1/4"

Page 12-4-30

Message Layout A

Layout B Square Edge panel

Layout C Round Edge Panel

2'-4"

2’-0"

Precast Concrete Post (7 1/2" Round) NC-07.02-C-c2

5"

1'-4"

6"

1 1/4"

3" 3/4" 3/4"

1'-3 3/4"

2'-4"

5"

1'-4"

1 1/4"

3" 3/4" 3/4"

1'-3 3/4"

Precast Concrete Post (7 1/2" Square) NC-07.02-B-c1

7 1/2"

3 3/4" 3 3/4"

Layout C Layout B

DRINK

DO

NOT

DRINK

DO

NOT

DRINK

4"

4 1/4"

4"

4 1/4"

FAUCET POST WITH SIGN PANEL

Scale: 3X5

FLOWER WATERING STATION

SEE SHEET CS501 FOR ADDITIONAL

DETAILS AND LAYOUT

12/2012 Page 12-4-33

National Cemetery Signs Wall Sign - Small

NC-08.01

Size 305 mm H x 457 mm W (12" H x 18" W)

Description and Use This sign has applied graphics and is informational.

Message Configuration (Refer to layout drawing for lettering sizes and dimensions) Layout A

Sign Components Vary by sign system.

Graphic Process Applied graphics

Colors Text: refer to color chart.

Background: refer to color chart.

Typography and Size Helvetica Bold

Mounting Double sided foam tape, silastic adhesive or screw.

Installation Secure to wall 60” above floor.

NOTE: Text to be verified at time of project / need.

m m

(6 0"

Wall mounted

Floral Regulations Fresh cut flowers may be placed on graves at any time.

Metal temporary containers are available.

Floral items will be removed from graves as soon as they become faded and unsightly.

Artificial flowers may be placed on graves only during the period of October 10 through April 15.

Plantings will not be permitted on graves at any time. Potted plants will be permitted on graves only during the period 10 days before and 10 days after Easter Sunday and Memorial Day.

Christmas wreaths or grave blankets are permitted on graves during the Christmas season and will be removed not later than January 20 of each year. Grave floral blankets maynot be larger in size than two by three feet.

During the lawn mowing and ground maintenance season, all floral items will be removed from graves on and of each month.

Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.

Floral items and other types of decorations will not be secured to headstones or markers.

Please contact Cemetery Director for information regarding installation of a permanent flower container.

NC-08.01

Floral Regulations Fresh cut flowers may be placed on graves at any time.

Metal temporary containers are available.

Floral items will be removed from graves as soon as they become faded and unsightly.

Artificial flowers may be placed on graves only during the period of October 10 through April 15.

Plantings will not be permitted on graves at any time. Potted plants will be permitted on graves only during the period 10 days before and 10 days after Easter Sunday and Memorial Day.

Christmas wreaths or grave blankets are permitted on graves during the Christmas season and will be removed not later than January 20 of each year. Grave floral blankets may not be larger in size than two by three feet.

During the lawn mowing and ground maintenance season, all floral items will be removed from graves on and of each month.

Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.

Floral items and other types of decorations will not be secured to headstones or markers.

Please contact Cemetery Director for information regarding installation of a permanent flower container.

A- Layout Floral Regulations

FLORAL REGUALTION SIGN

Scale: 2X6

18"

12"

AT FLOWER WATERING STATIONS

National Cemetery Signs Wall Sign - Small

NC-08.01

Message Layout A

1/2"

5/16" 1/2"

3/4"

3/4"

3/4"

5/16"

5/16"

14 mm (3/4")

Floral Regulations Fresh cut flowers may be placed on graves at any time.

Metal temporary containers are available.

Floral items will be removed from graves as soon as they become faded and unsightly.

Artificial flowers may be placed on graves only during the period of October 10 through April 15.

Plantings will not be permitted on graves at any time. Potted plants will be permitted on graves only during the period 10 days before and 10 days after Easter Sunday and Memorial Day.

Christmas wreaths or grave blankets are permitted on graves during the Christmas season and will be removed not later than January 20 of each year. Grave floral blankets may not be larger in size than two by three feet.

During the lawn mowing and ground maintenance season, all floral items will be removed from graves on and of each month.

Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.

Floral items and other types of decorations will not be secured to headstones or markers.

Please contact Cemetery Director for information regarding installation of a permanent flower container.

305 mm (12")

457 mm (18")

FLORAL REGULATION SIGN LAYOUT

Scale: 3X7

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

LOGAN BLVD

L O

G A

N B

LV

D

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

W

SHEET CG105

SHEET CG107SHEET CG108SHEET CG109

SHEET CG103

SHEET CG110

SHEET CG102

SHEET CG104

SHEET CG101

SHEET CG106

QUINCY AVE

NEW

PARKING AREA

PROJECT

BOUNDARY

ROAD B

ROAD A

R O

A D

B

RO

AD

B

ACCESS ROAD

PROJECT

BOUNDARY

PROJECT

BOUNDARY

PROJECT

BOUNDARY

PROJECT

BOUNDARY

G R

A V

E L

A C

C E

S S

R O

A D

OKLAHOMA ST

DENVER DR

DE

NV

ER

D

R

OMAHA DR

O M

A H

A D

R

K A

N S

A S

S T

W Y

O M

IN

G

S T

MONTANA ST

DENVER DRDENVER DR

UTAH ST

MEMORIAL

LAKE

COLORADO ST

COLORADO ST

COLORADO ST

S . S

H E

R

ID

A N

B

LV

D

KENYON AVE

S . S

H E

R

ID

A N

B

LV

D

VETERANS

LAKE

OMAHA DR

U T

A H

S T

R E

E T

COMITTAL

SHELTER

C

COMITTAL C

PARKING

COMITTAL

SHELTER B

COMITTAL

SHELTER A

LO

W

E

LL

B

LV

D

SHEET CG111

SHEET CG112

SHEET CG113

SHEET CG121

NORTH

OF

OVERALL GRADING SHEET

ETG JDS

CG100

51 165

LEGEND

KEYMAP

ENGINEER NOTES:

1-800-922-1987

NOTES:

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery…