S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(1 of 5).pdf

PDF 27 MB Posted

Attached to
Y1PC--Ft. Logan National Cemetery - Phase 1A Expansion (Construction FY23 Re-procurement)
Solicitation number
36C10F23R0013
Issued by

About this file

This document outlines a federal construction contract opportunity for the Phase 1A Expansion project at Fort Logan National Cemetery. The Department of Veterans Affairs, Office of Construction and Facilities Management, is seeking a firm-fixed-price construction contract to provide all labor, materials, equipment, and supervision necessary for the project as shown in the plans, drawings, and specifications. The project has an estimated construction cost between $20-50 million and is set aside 100% for Service-Disabled Veteran Owned Small Businesses. A pre-proposal site visit is scheduled and proposals are due by May 16, 2023 at 3:00 PM Eastern Time.

View the file

Other files

File Type Posted
S06 - 36C10F23R0013 0001 Amendment -PPI Response.pdf PDF
S06 - DOL Wage Determination CO20230002 04-07-2023.pdf PDF
S06 - Pre-Proposal Conference slides FLNC 4-19.pdf PDF
S06 - Ft. Logan Sign-in 4-19-23.pdf PDF
Bid Docs - Reports - Phase 1 Expansion Geotechnical Report.pdf PDF
S06 - 36C10F23R0013 Pre-Proposal Inquiry Responses.docx DOCX document
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(5 of 5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT3 - 2023 02 10(2 of 2).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (4of5).pdf PDF
S02 FT LOGAN NC PHASE 1A SPECIFICATIONS - 2023 02 21.pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(4 of 5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT2 - 2023 02 10(1 of 2).pdf PDF
S02 - DOL Wage Determination CO20230002 2-24-2023.pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(2 of 5).pdf PDF
S02 Pre-Proposal Inquiry (PPI) Form 36C10F23R0013.docx DOCX document
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (6 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (3of5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT3 - 2023 02 10(1 of 2).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (4 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (5 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (5of5).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT4 - 2023 02 10(3 of 5).pdf PDF
S02 - VAAR 852.219-75 VA Notice of Limitations on Subcontracting - Certification.pdf PDF
S02 - DOL Wage Determination CO20230009 2-24-2023.pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (3 of 6).pdf PDF
S02 Past Performance Questionnaire 36C10F23R0013.docx DOCX document
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (1of5).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (2 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-Base - 2023 02 10 (1 of 6).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT2 - 2023 02 10(2 of 2).pdf PDF
S02 FT LOGAN NC PHASE 1A-ALT1 - 2023 02 10 (2of5).pdf PDF
S02 - 36C10F23R0013 - Final - RFP - Ft Logan Phase 1A.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

© 2020 Microsoft Corporation © 2020 Maxar ©CNES (2020) Distribution Airbus DS

S H

E R

ID

A

N B

O U

LE

V

A R

D

LO

W

E

LL

B O

U

LE

V A

R D

US HIGHWAY 285

QUINCY AVENUE

OXFORD AVENUE

MARSTON LAKE

FE

D

E R

A L

B O

U

LE

V A

R D

FORT LOGAN

NATIONAL CEMETERY

LOGAN BOULEVARD

© 2020 Microsoft Corporation © 2020 Maxar ©CNES (2020) Distribution Airbus DS

DENVER DRIVE

OMAHA DRIVE

COLORADO STREET

NEW MEXICO STREET

S H

E R

ID

A

N B

O U

LE

V

A R

D

NORTH

VICINITY MAP LOCATION MAP

CONSULTANTS SITE DATA

CALIBRE ENGINEERING, INC. AQUA ENGINEERING APOGEE CONSULTING

SURVEY SYSTEMSFOURFRONT OCMI TERRACON CONSULTANTS

DEPARTMENT OF VETERANS AFFAIRS

FORT LOGAN NATIONAL CEMETERY

PHASE 1 DEVELOPMENT ON NEW LAND

VA PROJECT NO. 888-043

NORTH

JACOBS FORT LOGAN NATIONAL CEMETERYW.W. WHEELER & ASSOCIATES

INTERMENT SUMMARY

SECTION BURIAL TYPE CRYPTS

86 IN-GROUND CREMAINS 1,073

87 IN-GROUND CREMAINS 1,559

88 IN-GROUND CREMAINS 1,560

89 IN-GROUND CREMAINS 1,052

90 IN-GROUND CREMAINS 1,422

91 IN-GROUND CREMAINS 1,287

92 IN-GROUND CREMAINS 1,524

93 IN-GROUND CREMAINS 1,046

94 IN-GROUND CREMAINS 1,050

95 IN-GROUND CREMAINS 788

96 IN-GROUND CREMAINS 1,543

98 IN-GROUND CREMAINS 1,098

99 IN-GROUND CREMAINS 1,242

100 IN-GROUND CREMAINS 1,104

101 IN-GROUND CREMAINS 1,035

102 IN-GROUND CREMAINS 1,311

TOTAL IN-GROUND CREMAINS 19,694

97 OVERSIZED PPC 672

103 PPC 1,380

104 PPC 2,897

105 PPC 1,484

109 PPC 1,859

TOTAL PPC 7,620

COURT 4 COLUMBARIA 5,160

COURT 5 COLUMBARIA 5,400

TOTAL COLUMBARIA 10,560

TOTAL INTERMENT 38,546

OF

COVER SHEET

ETG RLB

G-001 1 165

H2B, INC

BASIS OF BEARINGS:

BENCHMARK:

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

ABBREVIATION LEGEND

1-800-922-1987

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

BRIAN STEPHENS-HOTOPP

PHASE 1A - ALTERNATE 4 BID DOCUMENTS

02 / 10 / 2023

PHASE IA - ALTERNATE 1

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

01 / 31 / 2023

OF

SHEET INDEX

ETG JDS

G-002 2 151

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

PHASE 1A - ALTERNATE 1B

BASH

PHASE 1A - ALTERNATE 4 BID DOCUMENTS

PHASE 1A - ALTERNATE 4

FORT LOGAN NATIONAL CEMETERY

PHASE 1 DEVELOPMENT ON NEW LAND

GENERAL NOTES GRADING NOTES STORMWATER POLLUTION PREVENTION PLAN (SWPPP)

COMPACTION NOTES

STORM WATER SEWER NOTES

PAVEMENT SUBGRADE

OF

GENERAL NOTES

ETG JDS

G-003 3 165

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

BASH02 / 10 / 2023

GENERAL CONSTRUCTION NOTES EROSION CONTROL NOTES: 2020-EC-0000039

FLOODPLAIN/FLOODWAY NOTES

ENGINEER NOTES

STANDARD NOTES - DENVER

2.

OF

GENERAL NOTES

ETG JDS

G-004 4 165

FORT LOGAN NATIONAL CEMETERY

RE-DEVELOPMENT ON EXISTING LAND

CD-1 DOCUMENTS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1 DEVELOPMENT ON NEW LAND

05-06-2021

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Roderick Grier (480)-842-1520

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A DEVELOPMENT ON NEW LAND

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

C.P.C.P.C.P.

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

W

COMMITTAL B

COMMITTAL A

COMMITTAL C

PROJECT

BOUNDARY

PROJECT

BOUNDARY

PROJECT

BOUNDARY

ENTRANCE 1

ENTRANCE 2

ENTRANCE 3

PHASE 1A

BOUNDARY

P.I.C.

BUILDING

COMMITTAL C

PARKING

COMMITTAL B

PARKING

COMMITTAL A

PARKING

GRAVEL ACCESS ROAD

MONTANA ST

ROAD B

ROAD A

R O

A D

B

RO

AD

B

G R

A V

E L

A C

C E

S S

R O

A D

OKLAHOMA ST

DENVER DR

DE

NVE

R

DR

OMAHA DR

O M

A H

A D

R

LOGAN BLVD

L O

G A

N B

LV

D

K A

N S

A S

S T

W Y

O M

IN

G

S T

DENVER DR

UTAH ST

MEMORIAL LAKE

COLORADO ST

COLORADO ST

NEW MEXICO ST

W. KENYON AVE

S . S

H E

R

ID

A N

B

LV

D

VETERANS LAKE

OMAHA DR

QUINCY AVE

LO

W

E

LL

B

LV

D

EX DETENTION POND

(SOUTH POND)

STOCKPILE

PINEHURST

ESTATES

PHASE 1A

BOUNDARY LINE

(INTERMENT)

MAINTENANCE

BUILDING

PERMANENT MATERIAL

STORAGE YARD

NEBRASKA ST

SEE NOTE 4

BELOW

SEE NOTE 4

BELOW

SEE NOTE 4

BELOW

SEE NOTE 4

BELOW

SEE NOTE 4

BELOW

SEE NOTE 4

BELOW

DENVER DR

PHASE 1B

BOUNDARY LINE

(DRAINAGE)

PHASE 1A

BOUNDARY

PHASE 1B

BOUNDARY

OF

CONSTRUCTION PHASE PLAN

PHASE 1-7

ETG RLB

G-005 5 165

PHASING NOTES:

PHASE 1:

PHASE 2:

PHASE 3:

PHASE 4:

PHASE 5:

PHASE 6

PHASE 7

PHASE 8

KEYMAP

1-800-922-1987

FLNC PH1A

STREET PHASING:

NORTH

FLNC PH1B

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

THIS LINEWORK WAS GIVENT TO US FROM SURVEY SYSTEMS

LINES ARE NOT CONNECTED. WHAT YOU SEE IS WHAT YOU GET

C.P.C.P.C.P.

M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

M

M

M

M

G R

A V

E L

A C

C E

S S

R O

A D

COMMITTAL B

COMMITTAL A

PARKING

COMMITTAL C

W

ROAD B

R O

A D

A

RO

AD

B

D E

N V

E R

S T

CEMETERY

BOUNDARY

PROJECT

BOUNDARY

PROJECT

BOUNDARY

PROJECT

BOUNDARY

EXISTING

STOCKPILE

MAIN CONSTRUCTION

ACCESS

P.I.C.

BUILDING

ROAD B

ROAD A

ROAD B

R O

A D

B

RO

AD

B

R O

A D

A G R

A V

E L

A C

C E

S S

R O

A D

ACCESS ROAD

COMMITTAL A

OKLAHOMA ST

D

EN

V

ER

D R

DENVER DR

D E

N V

E R

D R

OMAHA DR

O M

A H

A D

R

LOGAN BLVD

L O

G A

N B

LV

D

MONTANA ST

DENVER DRDENVER DR

UTAH ST

MEMORIAL

LAKE

COLORADO ST

COLORADO ST

COLORADO ST

NEW MEXICO ST

S . S

H E

R

ID

A N

B

LV

D

KENYON AVE

S . S

H E

R

ID

A N

B

LV

D

VETERANS

LAKE

GRAVEL ACCESS ROAD

OMAHA DR

U T

A H

S T

R E

E T

W Y

O M

IN

G

S T

R E

E T

K A

N S

A S

S T

R E

E T

COMMITTAL B

PARKING

COMMITTAL C

PARKING

PROJECT

BOUNDARY

PHASE 1

BOUNDARY LINE

NEBRASKA ST

MAINTENANCE

BUILDING

EXISTING

BUILDING

TEMP P.I.C

TRAILER

TEMP

RESTROOMS

TEMPORARY MATERIAL

STORAGE YARD

EX

COLUMBARIA

COURTS

COLUMBARIA

WALL

W Y

O M

IN

G

ST

K A

N S

A S

S T

LOGAN BLVD

COLUMBARIA

WALL

PERMANENT MATERIAL

STORAGE YARD

COLUMBARIA

COURT (NEW)

EX DETENTION POND

(SOUTH POND)

EXISTING ACCESS TO REMAIN

OPEN UNTIL ROAD B CONSTRUCTION

IS COMPLETE

QUINCY AVE

MAINTENANCE

BUILDING

KENYON AVE

NORTH

OF

CONSTRUCTION ACCESS PLAN

ETG RLB

G-006 6 165

KEYMAP

1-800-922-1987

LEGEND

NOTES:

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 419-6343

Environmental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

PHASE 1A DEVELOPMENT ON NEW LAND

11-03-2022

PRELIMINARY

NOT FOR CONSTRUCTION

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

V-103 V-104 V-105

V-107

V-108 V-109

V-111 V-112 V-113 V-114

V-115

V-116 V-117 V-118 V-119

V-120

V-121

V-102

V-106 V-110

NORTH LINE S 1/2 NE 1/4 SEC. 6, T5S, R68W 6TH P.M.NORTH LINE S 1/2 NW 1/4 SEC. 6, T5S, R68W 6TH P.M.V-101

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS

CROSS ACCEPTED

NORTHEAST 1/4 CORNER SECTION 6 TOWNSHIP 5 SOUTH RANGE 68 WEST

FOUND AXLE IN RANGE BOX 3' BELOW SURFACE

ACCEPTED CONTROL POINT

NORTHWEST 1/4 CORNER SECTION 6 TOWNSHIP 5 SOUTH RANGE 68 WEST

FOUND 3.25" ALUMINUM CAP

"COLORADO DEPARTMENT OF TRANSPORTAITION PLS 13258"

ACCEPTED

NORTH 1/4 CORNER SECTION 6 TOWNSHIP 5 SOUTH RANGE 68 WEST

FOUND #3 REBAR IN 6" SQUARE CONCRETE COLLAR

N89°40'47"E 2580.99' S89°43'07"W 2649.20'

THE PROJECT COORDINATE SYSTEM UTILIZED FOR THIS SURVEY CONTROL DIAGRAM IS COLORADO STATE

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

OF 165

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-100

EXISTING CONDITIONS SURVEY

OVERALL SHEET

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

VETERAN'S

LAKE

MEMORIAL

LAKE

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

PIN

PIN

S

PIN

S

ST

E E T

ST

E

ST

ST

ST

PIN

S

ST

16" RCP INVERT (NE)=5398.35'

30" RCP INVERT (N)=5398.53'

STORM MANHOLE

RIM=5405.99'

8" IRON INVERT (E)=5402.69'

8" IRON INVERT (S)=5402.79'

STORM MANHOLE

RIM=5404.93'

8" IRON INVERT (N)=5401.47'

8" IRON INVERT (W)=5401.61'

STORM INLET

FLOWLINE AT INLET=5404.91'

12" RCP INVERT OUT (NE)=5402.11'

STORM INLET

FLOWLINE AT INLET=5404.87'

12" RCP INVERT OUT (NE)=5401.67'

1" PVC INVERT IN (NE)=5403.42'

6" CMP INVERT (E)=5402.63'

12" RCP INVERT (SW)=5401.72'

PIN

S

PIN

S

FOUND #4 REBAR

ACCEPTED FOUND 2.5" BRASS CAP IN CONCRETE COLLAR

"UNITED STATES NATIONAL CEMETARY DEPARTMENT OF THE ARMY"

N0 0°

'15

"E

.6

3'

N89°41'28"W 786.05'

UT

AH

S

TR

EE

T

DENVER DRIVE

KA

NS

AS

S

TR

EE

T

W

YO

M

IN

G S

TR

EE

T

SH

ER

ID

AN

B O

UL

EV

AR

D

ACCEPTED FOUND 1.5" SINER

"PLS 38069"

STORM INLET

TOP OF INLET=5405.24'

12" RCP INVERT (E)=5403.04'

STORM INLET

FLOWLINE AT INLET=5405.25'

6" RCP INVERT OUT (NE)=5404.00'

S

STORM INLET

FLOWLINE AT INLET=5410.77'

18" RCP INVERT (E)=5406.88'

STORM INLET

FLOWLINE AT INLET=5410.30'

18" RCP INVERT (SW)=5406.70'

18" RCP INVERT (E)=5406.58'

STORM MANHOLE

RIM=5406.73'

8" INVERT (W)=5403.81'

8" INVERT (N)=5403.68'

STORM INLET

TOP OF INLET=5405.06'

12" RCP INVERT (W)=5401.06'

12" RCP INVERT (NE)=5400.96'

STORM MANHOLE

RIM=5404.72'

12" IRON INVERT (E)=5399.52'

12" IRON INVERT (SW)=5399.72'

ACCEPTED

FOUND 1.25" BROKEN ORANGE PLASTIC CAP

"DEA INC PLS 38069"

STORM MANHOLE

RIM=5404.78'

8" IRON INVERT (E)=5400.83'

8" IRON INVERT (S)=5401.01'

8" IRON INVERT (W)=5401.01'

CONCRETE

STORM MANHOLE

RIM=5412.16'

6" CLAY INVERT (E)=5409.53'

6" CLAY INVERT (S)=5409.81'

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-101

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-106 MATCH LINE SEE SHEET V-106

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V-

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

ST

ST

ST

STORM INLET

FLOWLINE AT INLET=5399.61'

24" RCP INVERT (NW)=5393.48'

INVERT (SW) IS PLUGGED

24" RCP INVERT (SE)=5395.96'

STORM INLET

FLOWLINE AT INLET=5398.74'

12" PVC INVERT (N)=5396.54'

12" RCP INVERT (S)=5396.65'

STORM INLET

FLOWLINE AT INLET=5398.75'

24" RCP INVERT (N)=5394.80'

18" RCP INVERT (S)=5395.11'

18" RCP INVERT (E)=5395.44'

STORM INLET

TOP OF INLET=5399.48'

12" HDPE INVERT (NW)=5397.46'

FLOWLINE AT INLET

TOP OF INLET=5399.29'

18" RCP INVERT (N)=5395.24'

FLOWLINE AT INLET

TOP OF INLET=5399.03'

12" RCP INVERT (N)=5397.50'

36" RCP INVERT (NE)=5368.90'

12" HDPE INVERT (SE)=5378.44'

STORM MANHOLE

RIM=5384.72'

12" HDPE INVERT OUT (SE)=5380.07'

12" HDPE INVERT IN (NW)=5380.14'

STORM MANHOLE

RIM=5388.62'

12" HDPE INVERT OUT (SE)=5381.89'

12" HDPE INVERT IN (W)=5381.92'

STORM MANHOLE

RIM=5394.40'

12" HDPE INVERT OUT (SE)=5385.50'

12" HDPE INVERT IN (W)=5385.58'

N89°49'27"W 1,704.92'

DENVER DRIVE

LO

G

AN

BO

UL

EV

AR

D

V-102

NORTH LINE S 1/2 NW 1/4 SEC. 6, T5S, R68W 6TH P.M.

STORM INLET

FLOWLINE AT INLET=5400.98'

12" RCP INVERT (E)=5398.18'

STORM INLET

FLOWLINE AT INLET=5401.65'

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-102

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-107

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T

MATCH LINE SEE SHEET V-107

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

GREASE TRAP MANHOLE

RIM=5368.47'

TOP OF GREASE=5361.77'

GREASE TRAP MANHOLE

RIM=5368.50'

TOP OF GREASE=5361.80' CLEANOUT

ST

36" RCP INVERT (NE)=5367.96'

36" RCP INVERT (NE)=5368.90'

12" HDPE INVERT (SE)=5378.44'

STORM MANHOLE

RIM=5384.72'

12" HDPE INVERT OUT (SE)=5380.07'

12" HDPE INVERT IN (NW)=5380.14'

4" PVC INVERT OUT (N)=5354.89'

72" RCP INVERT OUT (N)=5353.79'

4" PVC INVERT OUT (N)=5355.00'

34" RCP INVERT OUT (N)=5358.74'

34" RCP INVERT OUT (N)=5357.38'

FOUND MAG NAIL

W. KENYON AVENUE

DENVER DRIVE

SS SS CO

EDGE OF TURF

EDGE OF TURF

EDGE OF TURF

EDGE OF TURF

FLOWLINE AT INLET=5379.64'

18" RCP INVERT OUT (NE)=5376.65'

20" CORRUGATED PLASTIC INVERT (NE)=5369.47'

FLOWLINE AT INLET=5379.55'

20" CORRUGATED PLASTIC INVERT OUT (N)=5376.65'

18" RCP INVERT IN (SW)=5376.16

MAINTENANCE BUILDING

ASPHALT

LIMITS OF GRASS

GRAVEL

GRAVEL

20" RCP FLARED END SECTION INVERT=5350.44'

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-103

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-108

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

MATCH LINE SEE SHEET V-108

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

SS

COCO

SS

SANITARY SEWER MANHOLE

RIM=5347.09'

8" PVC INVERT IN (W)=5335.44'

8" PVC INVERT OUT (E)=5335.09'

SANITARY SEWER MANHOLE

RIM=5348.75'

8" PVC INVERT IN (SW)=5341.40'

8" PVC INVERT OUT (E)=5341.25'

SS

ST

ST

STORM MANHOLE

RIM=5362.60'

18" CORRUGATED PLASTIC INVERT IN (W)=5357.35'

24" CORRUGATED PLASTIC INVERT IN (S)=5357.28'

24" CORRUGATED PLASTIC INVERT OUT (N)=5356.98'

STORM MANHOLE

RIM=5363.48'

4" PVC INVERT IN (W)=5358.30'

24" CORRUGATED PLASTIC INVERT IN (S)=5358.22'

24" CORRUGATED PLASTIC INVERT OUT (N)=5358.17'

STORM MANHOLE

RIM=5362.32'

24" CORRUGATED PLASTIC INVERT IN (S)=5355.45'

36" CORRUGATED PLASTIC INVERT OUT (NE)=5354.42'

30" CORRUGATED PLASTIC INVERT IN (S)=5334.35'

36" CMP INVERT AT CENTER OF MANHOLE=5335.03'

36" INVERT OUT (NE)=5334.90'

STORM MANHOLE

RIM=5342.35'

36" CMP INVERT AT CENTER OF MANHOLE=5337.10'

UNABLE TO GET INVERTS

FLOWS FROM WEST TO EAST

STORM MANHOLE

RIM=5344.03'

36" CMP INVERT AT CENTER OF MANHOLE=5338.93'

UNABLE TO GET INVERTS

FLOWS FROM WEST TO EAST

STORM MANHOLE

RIM=5345.24'

INVERT AT CENTER OF MANHOLE=5340.14'

UNABLE TO GET INVERTS

36" CORRUGATED PLASTIC INVERT OUT (E)

36" CORRUGATED PLASTIC INVERT IN (W)

18" CORRUGATED PLASTIC INVERT IN (S)

FLOWLINE AT INLET=5346.16'

18" INVERT OUT (E)=5342.61'

FLOWLINE AT INLET=5346.47'

18" INVERT OUT (N)=5342.04'

18" INVERT IN (W)=5342.08'

ST

ST

ST

STST

ST

STST

ST

STORM MANHOLE

RIM=5346.16'

18" CORRUGATED PLASTIC INVERT IN (N)=5341.26'

36" CORRUGATED PLASTIC INVERT OUT (E)=5340.72'

36" CORRUGATED PLASTIC INVERT IN (W)=5340.66'

18" CORRUGATED PLASTIC INVERT IN (S)=5341.51'

FLOWLINE AT INLET=5346.03'

18" CORRUGATED PLASTIC INVERT OUT (S)=5341.50'

FLOWLINE AT INLET=5345.97'

18" CORRUGATED PLASTIC INVERT OUT (N)=5341.47'

18" CORRUGATED PLASTIC INVERT (NW)=5331.01'

18" CORRUGATED PLASTIC INVERT (NE)=5330.84'

FLOWLINE AT INLET=5333.60'

UNABLE TO COLLECT INVERTS

FULL OF DEBRIS

INVERT (W)

INVERT (E)

FLOWLINE AT INLET=5333.60'

UNABLE TO COLLECT INVERTS

FULL OF DEBRIS

INVERT (W)

INVERT (E)

STORM MANHOLE

RIM=5349.65'

36" CORRUGATED PLASTIC INVERT OUT (E)=5343.05'

36" CORRUGATED PLASTIC INVERT IN (W)=5343.40'

STORM MANHOLE

RIM=5355.41'

36" CORRUGATED PLASTIC INVERT OUT (E)=5347.41'

36" CORRUGATED PLASTIC INVERT IN (W)=5347.46'

STORM MANHOLE

RIM=5359.45'

36" CORRUGATED PLASTIC INVERT OUT (E)=5350.95'

36" CORRUGATED PLASTIC INVERT IN (SW)=5351.23'

FLOWLINE AT INLET=5362.57'

18" CORRUGATED PLASTIC INVERT OUT (E)=5358.65'

18" CORRUGATED PLASTIC INVERT IN (NW)=5358.81'

FLOWLINE AT INLET=5362.60'

18" CORRUGATED PLASTIC INVERT OUT (SE)=5358.94'

SANITARY SEWER MANHOLE

RIM=5361.56'

PVC INVERT IN (NW)=5347.84'

8" PVC INVERT OUT (NE)=5347.59'

6" INVERT (S)=5346.62'

6" INVERT (S)=5346.62'

BOTTOM OF INLET=5346.54

TOP OF CONCRETE=5348.39'

TOP OF PLATE=5347.81'

BOTTOM OF PLATE=5346.61'

FOUND MAG NAIL

N89°46'52"W 2,618.59'

COLO

RADO STR

EET

ARIZONA STREET

O M

AH

A

D

RI

VE

W. KENYON AVENUE

V-104

FLAG

POLE

NORTH LINE S 1/2 NE 1/4 SEC. 6, T5S, R68W 6TH P.M.

IRRIGATION PIPE

20" RCP FLARED END SECTION INVERT=5350.44'

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-104

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-109

M A

TC

H

L

IN

E

SE

E S

H

EE

T V-

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

MATCH LINE SEE SHEET V-109

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

SSCO

SS

SS

SANITARY SEWER MANHOLE

RIM=5336.02'

8" PVC INVERT IN (W)=5322.45'

8" PVC INVERT OUT (E)=5322.37'

SANITARY SEWER MANHOLE

RIM=5341.57'

8" PVC INVERT IN (W)=5323.55'

8" PVC INVERT OUT (E)=5323.62'

SANITARY SEWER MANHOLE

RIM=5332.82'

8" PVC INVERT IN (W)=5325.37'

8" PVC INVERT OUT (E)=5325.32'

ST ST ST ST

ST

ST

ST

ST

ST ST ST ST

ST

ST

ST

ST

ST

ST

STORM MANHOLE

RIM=5324.30'

48" RCP INVERT OUT (E)=5316.15'

48" RCP BOTTOM OF MANHOLE IN (S)=5316.45'

UNABLE TO GET INVERT IN OF PIPE

STORM MANHOLE

RIM=5324.06'

48" RCP INVERT OUT (E)=5315.06'

48" RCP INVERT IN (W)=5315.81'

36" RCP BOTTOM OF MANHOLE IN (S)=5315.64'

UNABLE TO GET INVERT IN OF PIPE

STORM MANHOLE

RIM=5324.13'

18" RCP INVERT OUT (S)=5317.88'

STORM MANHOLE

RIM=5330.54'

48" RCP INVERT OUT (E)=5313.19'

48" RCP INVERT IN (W)=5313.64'

STORM MANHOLE

RIM=5330.08'

INVERT OUT (N)=5312.28'

UNABLE TO DETERMINE SIZE AND TYPE OF PIPE

STORM MANHOLE

RIM=5324.15'

36" RCP INVERT OUT (N)=5318.15'

STORM MANHOLE

RIM=5324.21'

36" RCP INVERT OUT (N)=5318.21'

FLOWLINE AT INLET=5339.13'

30" CORRUGATED PLASTIC INVERT OUT (N)=5334.33'

18" CORRUGATED PLASTIC INVERT IN (S)=5334.83'

FLOWLINE AT INLET=5339.12'

30" INVERT OUT (N)=5334.12'

30" CORRUGATED PLASTIC INVERT IN (S)=5334.35'

STORM MANHOLE

RIM=5342.06'

18" CORRUGATED PLASTIC INVERT OUT (NE)=5336.81'

18" CORRUGATED PLASTIC INVERT IN (S)=5337.26'

STORM MANHOLE

RIM=5339.90'

30" INVERT OUT (NE)=5333.85'

INVERT IN (SW)=5333.95'

30" INVERT IN (S)=5333.95'

30" FLARED END SECTION INVERT (NE)=5331.59'

STORM MANHOLE

RIM=5340.03'

36" CMP INVERT AT CENTER OF MANHOLE=5335.03'

36" INVERT IN (W)=5334.95'

36" INVERT OUT (NE)=5334.90'

8" PLASTIC INVERT (N)=5333.73'

ST

ST

ST

COLORADO STREET

V-105

COLORADO STREET

NEW MEXICO STREET

SANITARY SEWER MANHOLE

RIM=5335.11'

12" PVC INVERT OUT (NNE)=5321.59'

12" PVC INVERT IN (S)=5321.89'

8" PVC INVERT IN (W)=5322.36'

FLOWLINE AT INLET=5346.30'

18" CMP INVERT OUT (NW)=5339.00'

18" CMP INVERT IN (SE)=5339.00'

FLOWLINE AT INLET=5345.25'

18" CMP INVERT OUT (NW)=5339.95'

12" INVERT IN (SE)=5340.10'

18" CMP INVERT (NW)=5337.18'

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-105

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-110

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

MATCH LINE SEE SHEET V-110

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

STORM INLET

FLOWLINE AT INLET=5417.38'

3" IRON INVERT (N)=5414.09'

15" CMP INVERT (E)=5413.29'

12" CMP INVERT (S)=5413.44

STORM INLET

FLOWLINE AT INLET=5425.22'

12" CMP INVERT (N)=5420.92'

12" CMP INVERT (S)=5421.27'

STORM INLET

FLOWLINE AT INLET=5414.64'

15" CMP INVERT (W)=5410.93'

20" CMP INVERT (E)=5410.69'

12" CMP INVERT (S)=5410.95'

STORM INLET

FLOWLINE AT INLET=5419.94'

12" CMP INVERT (N)=5415.20'

12" CMP INVERT (S)=5415.27'

STORM INLET

FLOWLINE AT INLET=5425.74'

12" CMP INVERT (N)=5420.87'

3" IRON INVERT (S)=5423.07'

STORM INLET

FLOWLINE AT INLET=5419.94'

12" RCP INVERT (N)=5411.39'

15" RCP INVERT (S)=5411.19'

STORM INLET

FLOWLINE AT INLET=5419.94'

15" RCP INVERT (E)=5409.43'

12" RCP INVERT (S)=5409.46'

STORM INLET

FLOWLINE AT INLET=5419.94'

12" RCP INVERT (N)=5411.83'

12" RCP INVERT (S)=5411.74'

STORM INLET

FLOWLINE AT INLET=5419.94'

12" RCP INVERT (N)=5409.99'

S0 0°

'56

"W

,4

.2 9'

SH

ER

ID

AN

B O

UL

EV

AR

D

W

YO

M

IN

G S

TR

EE

T

KA

NS

AS

S

TR

EE

T

MONTANA STREET

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-106

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-111 MATCH LINE SEE SHEET V-111

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V-

MATCH LINE SEE SHEET V-101MATCH LINE SEE SHEET V-101

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

18" CMP INVERT (SE)=5394.24'

STORM INLET

RIM=5403.52'

6" INVERT (SE)=5400.46'

STORM INLET

FLOWLINE AT INLET=5408.90'

18" CMP INVERT (SE)=5403.00'

18" CMP INVERT (NW)=5403.08'

STORM INLET

FLOWLINE AT INLET=5408.60'

18" CMP INVERT (SE)=5403.50'

18" RCP INVERT (NW)=5403.56'

STORM INLET

FLOWLINE AT INLET=5408.72'

18" CMP INVERT (SE)=5404.22'

6" PVC INVERT (NW)=5404.87'

18" CMP INVERT (SE)=5396.09'

STORM INLET

FLOWLINE AT INLET=5403.64'

16" RCP INVERT (SE)=5401.30'

16" RCP INVERT (NW)=5401.24'

STORM INLET

FLOWLINE AT INLET=5403.60'

16" RCP INVERT (NE)=5401.02'

18" RCP INVERT (SE)=5400.95'

12" RCP INVERT=5371.23'

12" RCP INVERT=5371.24'

STORM INLET

FLOWLINE AT INLET=5403.90'

18" RCP INVERT (E)=5400.19'

18" RCP INVERT (W)=5400.43'

STORM INLET

FLOWLINE AT INLET=5403.87'

18" RCP INVERT (E)=5400.17'

18" RCP INVERT (W)=5399.97'

STORM INLET

FLOWLINE AT INLET=5403.74'

18" RCP INVERT (E)=5399.84'

18" RCP INVERT (W)=5400.03'

STORM INLET

FLOWLINE AT INLET=5419.94'

16" RCP INVERT (E)=5405.69'

12" RCP INVERT (S)=5405.92'

12" RCP INVERT (W)=5406.16'

STORM INLET

FLOWLINE AT

INLET=5419.94'

12" RCP INVERT

(N)=5406.45'

LO

GA

N B

OU

LE

VA

RD

MONTANA STREET

STORM INLET

FLOWLINE AT INLET=5401.23'

16" CMP INVERT (N)=5397.90'

18" CMP INVERT (W)=5398.07'

STORM INLET

FLOWLINE AT INLET=5401.24'

16" CMP INVERT (E)=5398.48'

STORM INLET

FLOWLINE AT INLET=5400.98'

12" RCP INVERT (E)=5398.18'

STORM INLET

FLOWLINE AT INLET=5401.65'

24" RCP INVERT (N)=5398.09'

3" PVC INVERT (W)=5398.70'

20" RCP INVERT (S)=5398.31'

12" RCP INVERT (E)=5398.25'

OUTLET STRUCTURE

WATER LINE

WATER LINE

CONCRETE

POND OUTLET STRUCTURE

CONCRETE

STORM INLET

FLOWLINE AT INLET=5408.34'

18" CMP INVERT (SE)=5401.29'

18" CMP INVERT (NW)=5401.40'

MEMORIAL

LAKE

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-107

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-112MATCH LINE SEE SHEET V-112

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V-

MATCH LINE SEE SHEET V-102 MATCH LINE SEE SHEET V-102

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V

-1

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

ST

ST

ST

ST

ST

ST

STORM MANHOLE

RIM=5386.33'

18" CORRUGATED PLASTIC INVERT OUT (E)=5379.99'

18" CORRUGATED PLASTIC INVERT IN (SW)=5379.77'

STORM MANHOLE

RIM=5387.25'

18" CORRUGATED PLASTIC INVERT OUT (NE)=5380.65'

18" CORRUGATED PLASTIC INVERT IN (SW)=5380.50'

STORM MANHOLE

RIM=5388.96'

18" CORRUGATED PLASTIC INVERT OUT (NE)=5381.80'

18" CORRUGATED PLASTIC INVERT IN (SW)=5382.12'

STORM MANHOLE

RIM=5390.70'

18" CORRUGATED PLASTIC INVERT OUT (NNE)=5383.88'

18" CORRUGATED PLASTIC INVERT IN (S)=5383.16'

STORM MANHOLE

RIM=5392.46'

18" CORRUGATED PLASTIC INVERT OUT (NNW)=5384.21'

18" CORRUGATED PLASTIC INVERT IN (S)=5384.35'

STORM INLET

FLOWLINE AT INLET=5402.50'

18" RCP INVERT OUT (S)=5399.47'

12" RCP INVERT=5371.23'

12" RCP INVERT=5371.24'

STORM MANHOLE

RIM=5394.72'

12" CORRUGATED PLASTIC INVERT OUT (N)

12" CORRUGATED PLASTIC INVERT IN (S)

BOTTOM OF MANHOLE=5390.44'

UNABLE TO COLLECT INVERTS

STORM MANHOLE

RIM=5395.68'

12" CORRUGATED PLASTIC INVERT OUT (N)=5391.58'

12" CORRUGATED PLASTIC INVERT IN (S)=5391.59'

6" CORRUGATED PLASTIC INVERT IN (SW)=5391.62'

6" CORRUGATED PLASTIC INVERT IN (W)=5391.65'

STORM MANHOLE

RIM=5396.89'

12" CORRUGATED PLASTIC INVERT OUT (N)=5392.39'

6" CORRUGATED PLASTIC INVERT IN (SW)=5392.49'

6" CORRUGATED PLASTIC INVERT IN (W)=5392.44'

DENVER DRIVE

OMAHA DRIVE

COLORADO STREET

FLOWLINE AT INLET=5379.64'

18" RCP INVERT OUT (NE)=5376.65'

CREMATORIUM

WALL

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-108

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-113MATCH LINE SEE SHEET V-113

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V -1

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V-

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

MATCH LINE SEE SHEET V-103 MATCH LINE SEE SHEET V-103

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

WW

ST

ST

ST

ST

ST

ST

ST

STORM MANHOLE

RIM=5371.57'

24" CORRUGATED PLASTIC INVERT OUT (N)=5362.23'

24" CORRUGATED PLASTIC INVERT IN (S)=5362.25'

4" PVC INVERT IN (E)=5362.67'

STORM MANHOLE

RIM=5376.78'

24" CORRUGATED PLASTIC INVERT OUT (N)=5364.98'

24" CORRUGATED PLASTIC INVERT IN (S)=5365.02'

4" PVC INVERT IN (SE)=5365.11'

STORM MANHOLE

RIM=5379.46'

24" CORRUGATED PLASTIC INVERT OUT (N)=5368.12'

24" CORRUGATED PLASTIC INVERT IN (SW)=5368.54'

4" PVC INVERT IN (SE)=5369.05'

STORM MANHOLE

RIM=5380.93'

24" CORRUGATED PLASTIC INVERT OUT (NE)=5373.93'

18" CORRUGATED PLASTIC INVERT IN (S)=5374.62'

18" CORRUGATED PLASTIC INVERT IN (SE)=5374.33'

FLOWLINE AT INLET=5382.10'

18" CORRUGATED PLASTIC INVERT OUT (NNW)=5377.95'

18" CORRUGATED PLASTIC INVERT IN (E)=5378.76'

18" CORRUGATED PLASTIC INVERT IN (SSE)=5378.64'

FLOWLINE AT INLET=5382.12'

18" CORRUGATED PLASTIC INVERT OUT

(NNW)=5378.91'

STORM MANHOLE

RIM=5382.85'

18" CORRUGATED PLASTIC INVERT OUT (NE)=5376.84'

18" CORRUGATED PLASTIC INVERT IN (SW)=5376.89'

FLOWLINE AT INLET=5346.16'

18" INVERT OUT (E)=5342.61'

18" INVERT IN (W)=5342.08'18" CORRUGATED PLASTIC INVERT OUT (N)=5341.47'

FLOWLINE AT INLET=5362.57'

18" CORRUGATED PLASTIC INVERT OUT (E)=5358.65'

18" CORRUGATED PLASTIC INVERT IN (NW)=5358.81'

FLOWLINE AT INLET=5385.11'

18" CORRUGATED PLASTIC INVERT OUT (NE)=5381.47'

FLOWLINE AT INLET=5385.17'

18" CORRUGATED PLASTIC INVERT OUT (NW)=5380.94'

18" CORRUGATED PLASTIC INVERT IN (SW)=5381.00'

STORM MANHOLE

RIM=5385.84'

18" CORRUGATED PLASTIC INVERT OUT (NW)=5380.24'

18" CORRUGATED PLASTIC INVERT IN (SE)=5380.44'

STORM MANHOLE

RIM=5384.88'

18" CORRUGATED PLASTIC INVERT OUT (W)=5379.72'

18" CORRUGATED PLASTIC INVERT IN (SE)=5379.92'

STORM MANHOLE

RIM=5383.31'

18" CORRUGATED PLASTIC INVERT OUT (W)

18" CORRUGATED PLASTIC INVERT IN (E)

BOTTOM OF MANHOLE=5379.35'

UNABLE TO COLLECT INVERTS

COLO

RADO STR

EET

ARIZONA STREET

NEW MEXICO STREET

OMAHA DRIVE

V-109

OM

AHA DRIVE

NEBRASKA STREET

OMAHA DRIVE

CONCRETE

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-109

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-114

MATCH LINE SEE SHEET V-104MATCH LINE SEE SHEET V-104

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

MATCH LINE SEE SHEET V-114

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

MATCH LINE SEE

SHEET V-114 PHASE 1A - ALTERNATE 4 BID DOCUMENTS

FLOWLINE AT INLET=5361.83'

18" INVERT OUT (NW)=5352.48'

18" INVERT IN (SE)=5352.76'

UNABLE TO DETERMINE PIPE TYPE

STORM MANHOLE

RIM=5361.80'

18" CORRUGATED PLASTIC INVERT OUT (N)=5350.55'

18" CORRUGATED PLASTIC INVERT IN (SE)=5350.75'

ST

18" FLARED END SECTION INVERT (N)=5372.27'

N0 0°

'28

"W

,3

.0 9'

LOGAN CIRCLE

NEW MEXICO STREET

COLORADO STREET

N0 0°

'56

"W

.38

CONCRETE

GARVEL

GATE

GARVEL

PHASE 1A

CONSTRUCTION

LIMITS

PHASE 1A

CONSTRUCTION

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-110

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-115

MATCH LINE SEE SHEET V-105

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V-

MATCH LINE SEE SHEET V-115

MATCH LINE SEE SHEET V-105

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

SS

SANITARY SEWER MANHOLE

RIM=5440.78'

8" PVC INVERT OUT (NW)=5428.53'

8" PVC INVERT IN (SE)=5428.63'

E

ST ST

ST

E

18" PVC INVERT (SE)=5430.68'

18" PVC INVERT (SE)=5430.05'

STORM MANHOLE

POSSIBLE DETENTION VAULT

WITH CONCRETE WALL DIVIDING MANHOLES

SEVERAL FEET OF STANDING WATER

RIM=5430.87'

4" IRON INVERT (E)=5426.77'

BOTTOM OF BOX=5423.11'

STORM INLET

FLOWLINE AT INLET=5420.52'

18" RCP INVERT (SE)=5417.74'

STORM INLET

FLOWLINE AT INLET=5419.92'

18" RCP INVERT (NW)=5417.07'

18" CMP INVERT (SE)=5416.72'

STORM INLET

FLOWLINE AT INLET=5420.85'

18" CMP INVERT (NW)=5417.30'

18" CMP INVERT (SE)=5417.36'

STORM INLET

FLOWLINE AT INLET=5420.92'

18" CMP INVERT (NW)=5417.03'

18" CMP INVERT (E)=5416.83' STORM INLET

FLOWLINE AT INLET=5419.02'

18" CMP INVERT (W)=5416.28'

18" CMP INVERT (E)=5416.18'

STORM INLET

FLOWLINE AT INLET=5441.22'

8" PVC INVERT OUT (SE)=5437.03'

STORM INLET

FLOWLINE AT INLET=5441.25'

8" PVC INVERT IN (NW)=5436.54'

18" PVC INVERT OUT (SE)=5436.25'

STORM MANHOLE

RIM=5441.33'

18" PVC INVERT IN (NW)=5435.93'

18" PVC INVERT OUT (SE)=5435.78'

STORM INLET

FLOWLINE AT

INLET=5435.70'

18" PVC OUT

(SE)=5431.41'

STORM INLET

FLOWLINE AT INLET=5433.78'

12" CMP INVERT (N)=5430.14'

12" CMP INVERT (W)=5430.25'

LOGAN BOULEVARD

KA

NS

AS

S

TR

EE

T

W

YOM

ING STREET

OM

AHA DRIVE

SH

ER

ID

AN

BO

UL

EV

AR

D

36" CMP INVERT (NE)=5412.17'

36" CMP INVERT (NE)=5412.18'

30" CMP INVERT (NE)=5412.16'

SANITARY SEWER MANHOLE

RIM=5433.96'

8" PVC INVERT OUT (NW)=5430.56'

8" PVC INVERT IN (S)=5430.61'

STORM MANHOLE

POSSIBLE DETENTION VAULT

WITH CONCRETE WALL DIVIDING MANHOLES

SEVERAL FEET OF STANDING WATER

RIM=5431.20'

4" IRON INVERT (W)=5427.16'

BOTTOM OF BOX=5423.20'

SANITARY SEWER MANHOLE

RIM=5439.49'

8" PVC INVERT OUT (NW)=5429.44'

8" PVC INVERT IN (SE)=5429.54'

POND

VISITOR CENTER

CONCRETE

RIP-RAP

CONCRETE

WALL

WALL

BUILDING

CONCRETE

WATER LINE

WATER LINE

WALL

36" HDPE INVERT (SW)=5414.04'

36" CMP INVERT (SW)=5413.34'

STORM INLET

FLOWLINE AT INLET=5418.89'

18" CMP INVERT (W)=5415.82'

18" CMP INVERT (E)=5415.69'

PHASE 1B

PROPOSED

BOUNDARY

PHASE 1B

PROPOSED

BOUNDARY

PHASE 1B

PROPOSED

BOUNDARY

VETERAN'S

LAKE

VETERAN'S LAKE

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-111

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-116

MATCH LINE SEE SHEET V-106MATCH LINE SEE SHEET V-106

MATCH LINE SEE SHEET V-116

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M

A

TC

H L

IN

E

SE

E

SH

EE

T V-

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE 1A - ALTERNATE 1B BID DOCUMENTS

01 / 31 / 2023

T

H 02

ST

ST

ST

ST

STORM INLET

FLOWLINE AT INLET=5408.00'

24" INVERT OUT (N)=5396.35'

24" CMP INVERT IN (E)=5396.38'

36" RCP INVERT IN (SW)=5401.44'

STORM INLET

FLOWLINE AT INLET=5408.64'

24" CORRUGATED PLASTIC INVERT OUT (E)=5404.91'

STORM MANHOLE

RIM=5422.55'

30" RCP INVERT OUT (NE)=5417.65'

UNABLE TO DETERMINE PIPE SIZE AND TYPE INVERT IN (S)=5417.80'

STORM MANHOLE

RIM=5408.22'

24" CMP INVERT OUT (N)=5396.28'

24" INVERT IN (S)=5396.22'

24" CORRUGATED PLASTIC INVERT IN (W)=5404.07'

FLOWLINE AT INLET=5429.05'

24" RCP INVERT OUT (N)=5422.22'

24" RCP INVERT IN (S)=5422.46'

18" CMP FLARED END SECTION INVERT (E)=5394.60'

POSSIBLE IRRIGATION MANHOLE

RIM=5433.37'

12" IRON PIPE RUNNING EAST/WEST

36" CMP FLARED END SECTION INVERT (E)=5393.22'

30" CMP FLARED END SECTION INVERT (E)=5393.32'

36" CMP FLARED END SECTION INVERT (E)=5393.84'

FOUND SHINER

"527"

OM

AHA DRIVE

OMAHA DRIVE

DE

NV

ER

D

RI

VE

DENVER DRIVE

N89°44'39"W 5245.53'

POND

WATER LINE

WATER LINE

WATER LINE

CONCRETE

RIP-RAP

STORM INLET

FLOWLINE AT INLET=5418.89'

18" CMP INVERT (W)=5415.82'

18" CMP INVERT (E)=5415.69'

RIP-RAP

PHASE 1B

DRAINAGE

IMPROVEMENT

LIMITS

APPROVED DRAWING TITLE

DATE

LOCATION

CHECKED PROJECT NUMBER

DRAWING NUMBER

DESCRIPTION DATE

DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:

C

Office of Construction and Facilities Management

1 3 4 5 6

B

A

D

E

C

B

A

D

E

BUILDING NUMBER

DRAWN

SEAL:

MARK

DENVER, COLORADO

888-043

FORT LOGAN

NATIONAL CEMETERY

Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying

Calibre Engineering, Inc.

Cemetery Expertise:

Jacobs Bill Romzick

(989) 745-1048

Architect:

Fourfront James Lushbough

(605) 342-9470

Irrigation:

Aqua Engineering Bob Beccard

(970) 372-6104

MEP, Fire, Landscape RCDD:

APOGEE Consulting Mark Norris

(919) 535-3819

Surveying & GPS:

Survey Systems Matt Nichols

(303) 679-8122

Enviromental & Geotechnical Engineering:

Terracon Consultants Jennifer Peters/John Haas

(210) 907-7648/(303) 454-5265

Cost Estimating:

OCMI

Kyle Veater

(757) 803-7517

JR MN

V-112

EXISTING CONDITIONS SURVEY

DETAIL SHEET

MATCH LINE SEE SHEET V-107

MATCH LINE SEE SHEET V-117

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V -1

M

A

TC

H L

IN

E

SE

E

SH

EE

T V

-1

M A

TC

H

L

IN

E

SE

E

SH

EE

T

V-

MATCH LINE SEE SHEET V-117

DRAWING INDEX

BENCHMARK:

#160A

CONTROL POINT :

BASIS OF BEARINGS:

NOTES:

1-800-922-1987

NORTH

LEGEND

ST

SS

IP

S

C.P.

CROSS

T

CONCRETE

MATCH LINE SEE SHEET V-107

Structural Engineer:

H2B, Inc Tod Henning

(713) 864-2910 OF 165

PHASE 1A DEVELOPMENT ON NEW LAND

PRELIMINARY

NOT FOR CONSTRUCTION

PHASE 1A - ALTERNATE 1 BID DOCUMENTS

11 / 03 / 2022

12/16/2022

PHASE…

This is the start of the file's text. The full file is on GovTribe.