S02 - ATTACHMENT 7 - COMBINED-MEP_FP_IT_06012023_Part3.pdf

PDF 18 MB Posted

Attached to
EHRM Infrastructure Upgrades Construction - Central Western Massachusetts Federal contract opportunity
Solicitation number
36C77623R0051
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This file provides details on a federal construction solicitation. The solicitation number is 36C77623R0051 and seeks construction services for EHRM Infrastructure Upgrades - Central Western Massachusetts. The solicitation is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin as a design-bid-build project. Responses are due on June 1, 2023. Construction services will include upgrades to infrastructure at medical centers in Central Western Massachusetts. Interested parties should monitor the Federal Business Opportunities website for additional details and amendments to requirements.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Infrastructure Upgrades Construction - Central Western Massachusetts, newest first.
File Type Posted
Technical Questions Cont. - CWM EHRM.pdf PDF
36C77623R0051 0006 - CWM EHRM - RFIs Cont and Language.pdf PDF
Attachment 5 - GC402-REVISED_07_19_2023_ADDENDUM2.pdf PDF
Attachment 3 - BASEMENT LEVEL ELECTRICAL PLAN - WEST - LIBERTY BLDG.pdf PDF
Attachment 2 - EHRM CWM - Geotechnical Engineering Report.pdf PDF
Attachment 4 - BASEMENT LEVEL ELECTRICAL PLAN - EAST - LIBERTY BLDG.pdf PDF
Attachment 6 - 1-AE120-REVISED_07_19_2023_ADDENDUM2.pdf PDF
36C77623R0051 0005 - EHRM CWM - Extension and RFIs.pdf PDF
Attachment 1 - Technical Questions - CWM EHRM VA Response.pdf PDF
Site Visit 2 Sign-in Sheet - CWM EHRM.pdf PDF
EHRM EP601 Addendum 1 6-15-2023 .pdf PDF
Site Visit 2 Sign-in Sheet - CWM EHRM.pdf PDF
36C77623R0051 0004 - EHRM CWM.pdf PDF
Updated Book 1.pdf PDF
Updated Book 3.pdf PDF
Second Site Visit Instructions.pdf PDF
36C77623R0051 0003 - CWM - Second Site Visit and Extension of RFIs.pdf PDF
36C77623R0051 0002 - CWM EHRM - Extend Deadline for RFIs.pdf PDF
Site Visit Sign In Sheet - Central Western Massachusetts.pdf PDF
36C77623R0051 0001 - CWM Sign In Sheet.pdf PDF
S02 - Solicitation - 36C77623R0051 - CWM EHRM.pdf PDF
S02 - ATTACHMENT 2 - SPEC BOOK 2.pdf PDF
S02 - ATTACHMENT 8 - COMBINED-MEP_FP_IT_06012023_Part4.pdf PDF
S02 - ATTACHMENT 10 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 2.pdf PDF
S02 - ATTACHMENT 12 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 4.pdf PDF
S02 - ATTACHMENT 14 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 6.pdf PDF
S02 - ATTACHMENT 24 - Contractor Safety - Environmental Form.pdf PDF
S02 - ATTACHMENT 26 - Hampshire County Wage Rates 03.31.2023.pdf PDF
S02 - ATTACHMENT 27 - Site Visit Instructions.pdf PDF
S02 - ATTACHMENT 17 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 9.pdf PDF
S02 - ATTACHMENT 5 - COMBINED-MEP_FP_IT_06012023_Part1.pdf PDF
S02 - ATTACHMENT 11 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 3.pdf PDF
S02 - ATTACHMENT 16 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 8.pdf PDF
S02 - ATTACHMENT 18 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 10.pdf PDF
S02 - ATTACHMENT 19 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 11.pdf PDF
S02 - ATTACHMENT 20 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 12.pdf PDF
S02 - ATTACHMENT 3 - SPEC BOOK 3.pdf PDF
S02 - ATTACHMENT 4 - SPEC BOOK 4.pdf PDF
S02 - ATTACHMENT 13 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 5.pdf PDF
S02 - ATTACHMENT 9 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 1.pdf PDF
S02 - ATTACHMENT 1 - SPEC BOOK 1.pdf PDF
S02 - ATTACHMENT 6 - COMBINED-MEP_FP_IT_06012023_Part2.pdf PDF
S02 - ATTACHMENT 15 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 7.pdf PDF
S02 - ATTACHMENT 21 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 13.pdf PDF
S02 - ATTACHMENT 22 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 14.pdf PDF
S02 - ATTACHMENT 23 - Brand Name Justification - CWM EHRM - Redacted.pdf PDF
S02 - ATTACHMENT 25 - Limitations on Subcontracting.pdf PDF
Show all 47

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10A

8A

6 5

147a

12 13

LOADING

DOCK LOADING

DOCK

TR

14-3

14-EP101

BUILDING NO. 14 - FIRST LEVEL

ELECTRICAL PLAN 14

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\1 4-

EP

BU

IL

D

IN

G

N O

. 1

FI

R

ST

L

EV

EL

E

LE

C

TR

IC

AL

P

LA

N

.d w g

1/ 2/

4:

:3

PM

AutoCAD SHX Text

EXISTING PANEL 14-104

AutoCAD SHX Text

EXISTING PANEL 14-103

AutoCAD SHX Text

EXISTING METAL SHOP PANEL

AutoCAD SHX Text

EXISTING 30KVA XFMR (ABOVE)

AutoCAD SHX Text

EXISTING PANEL 14-101

AutoCAD SHX Text

EXISTING PANEL 14-102

AutoCAD SHX Text

EXISTING 30KVA XFMR (ABOVE)

AutoCAD SHX Text

EXISTING PANEL 14-100

AutoCAD SHX Text

EXISTING PANEL 14-MDP

AutoCAD SHX Text

METERING PANEL

AutoCAD SHX Text

PANEL E14LS-100

AutoCAD SHX Text

SPD PANEL

AutoCAD SHX Text

NEW NETWORK CLOSET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 7A

AutoCAD SHX Text 8A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 10A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Loading Dock

AutoCAD SHX Text Loading Dock

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

FENCE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

%%U BUILDING NO. 14 - FIRST LEVEL ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

BUILDING 14 ONE-LINE

AutoCAD SHX Text

BUILDING 14

AutoCAD SHX Text

FROM TRANSFORMER TR2

AutoCAD SHX Text

14-MDP

AutoCAD SHX Text 277/480

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 1200A 3P

AutoCAD SHX Text 14-100

AutoCAD SHX Text 277/480

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 400A 3P

AutoCAD SHX Text 14-101

AutoCAD SHX Text 277/480

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 400A 3P

AutoCAD SHX Text 14-103

AutoCAD SHX Text 277/480

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 400A 3P

AutoCAD SHX Text

14-102-TR 45KVA 480Y/277V TO 208/120V

AutoCAD SHX Text 14-102

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text

14-104-TR 45KVA 480Y/277V TO 208/120V

AutoCAD SHX Text 14-104

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

METERING

AutoCAD SHX Text

PANEL

AutoCAD SHX Text

EXISTING EQUIPMENT TO BE REMOVED REFER TO NOTES FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

EXISTING TO REMAIN REFER TO SUMMARY OF WORK NOTES FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

NEW WORK REFER TO NOTES FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

E14LS-100

AutoCAD SHX Text 208/120

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A/3P

AutoCAD SHX Text FROM BUILDING No. 65

AutoCAD SHX Text

SURGE

AutoCAD SHX Text

PROTECTIVE

AutoCAD SHX Text

DEVICE

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

14-103-TR 15KVA 480Y/277V TO 208/120V

AutoCAD SHX Text 14-106

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text

GROUND BUS BAR (TYPICAL)

AutoCAD SHX Text

14-102-TR 15KVA 480Y/277V TO 208/120V

AutoCAD SHX Text 14-105

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text

TR ROOM

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text PROVIDE (2) 25A/3P CIRCUIT BREAKERS FOR TRANSFORMERS. MATCH EXISTING EATON TYPE, STYLE AND AIC RATING.

TR

14-3

14-EP401

BUILDING NO. 14 - ENLARGED TR

ROOM PLANS 14

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\1 4-

EP

BU

IL

D

IN

G

N O

. 1

- E N

LA

R

G

ED

T R

R O

O M

P

LA

N S.

dw g

1/

2/

4:

:3

PM

AutoCAD SHX Text

PANEL 14-105 & XFMR ABOVE

AutoCAD SHX Text 14-105-6

AutoCAD SHX Text

CU-14-2

AutoCAD SHX Text 14-105 -14,16

AutoCAD SHX Text

CU-14-1

AutoCAD SHX Text 14-106 -14,16

AutoCAD SHX Text

ERV-14-1

AutoCAD SHX Text 14-105-2

AutoCAD SHX Text 14-105 -1,3.5

AutoCAD SHX Text 14-106 -1,3,5

AutoCAD SHX Text 14-105-4

AutoCAD SHX Text 14-105-6

AutoCAD SHX Text

AC-14-1

AutoCAD SHX Text 14-106-2

AutoCAD SHX Text 14-106-4

AutoCAD SHX Text

AC-14-2

AutoCAD SHX Text

GROUND BAR (SC-GND-1)

AutoCAD SHX Text

PANEL 14-106 & XFMR ABOVE

AutoCAD SHX Text EQUIPMENT LOCATED ON ROOF ABOVE TR ROOM. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION

AutoCAD SHX Text 14-105-12

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 14 - SECOND FLOOR TR ROOM ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 2'

PANEL NOTES: 1. ALL CIRCUITS 150V TO GROUND AND 50 AMPS OR LESS ALL CIRCUITS 150V TO GROUND AND 50 AMPS OR LESS SUPPLYING EXTERIOR, BASEMENT, WET OR DAMP LOCATIONS SHALL BE PROVIDED WITH GROUND FAULT CIRCUIT PROTECTION PER NEC ARTICLE 210.8. THE REQUIREMENT INCLUSE RECEPTACLES, AIR CONDITIONING AND CONDENSING UNITS.

DOWN

DOWN

16-EP101

BUILDING NO. 16 FIRST & SECOND

LEVEL ELECTRICAL PLANS 16

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\1 6-

EP

BU

IL

D

IN

G

N O

. 1

FI

R

ST

S

EC

O N

D L

EV

EL

E

LE

C

TR

IC

AL

P

LA

N S.

dw g

/2

/2

4:

:3

PM

AutoCAD SHX Text

ELEV-CB

AutoCAD SHX Text

EXISTING PANEL E15-BDP

AutoCAD SHX Text Salvage Items

AutoCAD SHX Text Scrap Items

AutoCAD SHX Text

SCRAP ITEMS AREA

AutoCAD SHX Text

UNICOR STORAGE

AutoCAD SHX Text

SALVAGE ITEMS AREA

AutoCAD SHX Text

EXCESS EQUIPMENT

AutoCAD SHX Text

AREA

AutoCAD SHX Text B104

AutoCAD SHX Text B107

AutoCAD SHX Text B103

AutoCAD SHX Text B105

AutoCAD SHX Text

ELECTRICAL RM

AutoCAD SHX Text

BAY 2 EXIT DOOR

AutoCAD SHX Text

DOCK

AutoCAD SHX Text

CYLINDER STORAGE

AutoCAD SHX Text

FREIGHT

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

BOILER PLANT

AutoCAD SHX Text

PHARMACY DRUG CACHE

AutoCAD SHX Text B106

AutoCAD SHX Text

ACCESS EQUIPMENT

AutoCAD SHX Text

TR

AutoCAD SHX Text 16-B101

AutoCAD SHX Text

EXISTING PANEL E16-100

AutoCAD SHX Text

SUB-PANEL

AutoCAD SHX Text

EXISTING PANEL E16-101

AutoCAD SHX Text

EXIST. PANEL E16LS-1

AutoCAD SHX Text

RM102

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

TR

AutoCAD SHX Text 101A

AutoCAD SHX Text

BREAK ROOM

AutoCAD SHX Text

ROOM 105

AutoCAD SHX Text

MAIL ROOM AREA

AutoCAD SHX Text

ROOM 104

AutoCAD SHX Text

WAREHOUSE AREA

AutoCAD SHX Text

ROOM 101

AutoCAD SHX Text

MED GAS STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

DOCK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

FIRST LEVEL ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

BASEMENT ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

4'

DN

BOILER PLANT

B102

704SF

161 SF

TR

16-B101

DOWN

16-EP401

BUILDING NO. 16 ENLARGED TR

ROOM PLANS 16

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\1 6-

EP

BU

IL

D

IN

G

N O

. 1

EN

LA

R G

ED

T

R R

O O

M P

LA

N

S.

dw g

1/ 2/

4:

:3

PM

AutoCAD SHX Text

GROUND BAR (SC-GND-1)

AutoCAD SHX Text

PANEL E16-B1

AutoCAD SHX Text

PANEL E16-B2

AutoCAD SHX Text E16-102 100-6

AutoCAD SHX Text

CU-16-2

AutoCAD SHX Text E16-102 -14,16

AutoCAD SHX Text

CU-16-1

AutoCAD SHX Text E16-103 -14,16

AutoCAD SHX Text

CU-16-3

AutoCAD SHX Text

CU-16-4

AutoCAD SHX Text

CU-16-5

AutoCAD SHX Text 16B1 -14,16

AutoCAD SHX Text E16-B2 -14,16

AutoCAD SHX Text

AC-16-1

AutoCAD SHX Text

AC- 16-2

AutoCAD SHX Text E16- B2-2

AutoCAD SHX Text E16-B2-6

AutoCAD SHX Text E16-B1 -1,3.5

AutoCAD SHX Text E16-B2 -1,3,5

AutoCAD SHX Text E16-B1-4

AutoCAD SHX Text E16-B2-4

AutoCAD SHX Text E16-B1 -12

AutoCAD SHX Text

GROUND BAR (SC-GND-1)

AutoCAD SHX Text

PANEL E16-102

AutoCAD SHX Text

PANEL E16-103

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

TR

AutoCAD SHX Text 101A

AutoCAD SHX Text

ERV -16-1

AutoCAD SHX Text E16-102 -2

AutoCAD SHX Text E16-103 201-2

AutoCAD SHX Text E16-103-6

AutoCAD SHX Text E16-102 -1,3.5

AutoCAD SHX Text E16-103 -1,3,5

AutoCAD SHX Text E16-102 -4

AutoCAD SHX Text

E4CB- 201-4

AutoCAD SHX Text

AC- E16-4

AutoCAD SHX Text

AC-E16-3

AutoCAD SHX Text

AC-16-5

AutoCAD SHX Text E16-102 -12

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 16 - BASEMENT TR ROOM ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 2'

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 16 - FIRST FLOOR TR ROOM ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

2'

16-EP601

BUILDING NO. 16 - ONE-LINE

DIAGRAM 16

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\1 6-

EP

BU

IL

D

IN

G

N O

. 1

- O N

E-

LI

N E

D

IA

G R

AM

.d w g

1/

2/

:1 6:

P

M

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

BUILDING 16 ONE-LINE

AutoCAD SHX Text

BUILDING 15

AutoCAD SHX Text

FIRST LEVEL

AutoCAD SHX Text

FROM PANEL E15-MDP

AutoCAD SHX Text

BUILDING 16

AutoCAD SHX Text

FIRST LEVEL

AutoCAD SHX Text

BASEMENT LEVEL

AutoCAD SHX Text

E16-100-TR 6KVA 240/120V TO 208/120V

AutoCAD SHX Text E16-100

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text E16-100A

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text E16-101

AutoCAD SHX Text 120/240

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text

FROM PANEL E15-BDP DWG. 15-ES601

AutoCAD SHX Text

ELEV CB.

AutoCAD SHX Text

FROM PANEL E15-BDP

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

EXISTING EQUIPMENT TO BE REMOVED REFER TO NOTES FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

EXISTING TO REMAIN REFER TO SUMMARY OF WORK NOTES FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

NEW WORK REFER TO NOTES FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

E16LS-1

AutoCAD SHX Text 208/120

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text

FROM BUILDING NO. 65 PANEL E65LS-1

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text E16-102

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text E16-103

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 125A 3P

AutoCAD SHX Text E16-B1

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 100A 3P

AutoCAD SHX Text E16-B2

AutoCAD SHX Text 120/208

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 125A 3P

AutoCAD SHX Text

GROUND BUS BAR (TYPICAL)

AutoCAD SHX Text

TR ROOM

AutoCAD SHX Text

TR ROOM

AutoCAD SHX Text

GROUND BUS BAR (TYPICAL)

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

E15-BDP

AutoCAD SHX Text 208/120

AutoCAD SHX Text 3%%c, 4W

AutoCAD SHX Text 400A 3P

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

PROVIDE (2) 100A/3P BREAKERS FOR NEW PANELS. MATCH EXISTING EATON TYPE

AutoCAD SHX Text PANEL NOTES: 1. ALL CIRCUITS 150V TO GROUND AND 50 AMPS OR LESS ALL CIRCUITS 150V TO GROUND AND 50 AMPS OR LESS SUPPLYING EXTERIOR, BASEMENT, WET OR DAMP LOCATIONS SHALL BE PROVIDED WITH GROUND FAULT CIRCUIT PROTECTION PER NEC ARTICLE 210.8. THE REQUIREMENT INCLUSE RECEPTACLES, AIR CONDITIONING AND CONDENSING UNITS.

KEYNOTES: PROVIDE 16" (UNLESS NOTED OTHERWISE FOR 20") GROUND BUS BAR PER COMMUNICATIONS DRAWINGS AT PANELS AS INDICATED. REFER TO TELECOMMUNICATION DRAWINGS AND DIVISION 27 SPECIFICATIONS

UP

SAFETY

STOR.

032MECH.

SUPERVISORY

ENGINEER

FMD CHIEF

ASSIST. CHIEF

STAIR

OFFICE

CORR.

95 SF

TR

20-034

TOILET

CL.

COPY/

STOR.

SHARED

OFFICE

SHARED

OFFICE

97 SF

TR

121 SF

OFFICE

T

A1

SHARED

OFFICE

F1

A1

FISCAL

20-131

TR

20-132A

ELECTRICAL

20-132B

AC-20-4

AC-20-3

20-EP401

BUILDING NO. 20 ENLARGED TR

ROOM PLANS 20

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\2 0-

EP

BU

IL

D

IN

G

N O

. 2

EN

LA

R G

ED

T

R R

O O

M P

LA

N

S.

dw g

1/ 2/

4:

:3

PM

AutoCAD SHX Text

CU-20-1

AutoCAD SHX Text

CU-20-2

AutoCAD SHX Text

CU-20-3

AutoCAD SHX Text

CU-20-4

AutoCAD SHX Text

CU-20-5

AutoCAD SHX Text

CU-20-6

AutoCAD SHX Text

AC-20-1

AutoCAD SHX Text

AC-20-2

AutoCAD SHX Text

AC-20-5

AutoCAD SHX Text

AC-20-6

AutoCAD SHX Text

GROUND BAR (SC-GND-1)

AutoCAD SHX Text

EXISTING RELOCATED PANEL P2

AutoCAD SHX Text

EXISTING RELOCATED PANEL P1

AutoCAD SHX Text EXISTING PANEL P1 TO BE RELOCATED TO NE TR ROOM WALL. EXTEND WIRE AND CONDUIT TO NE LOCATION

AutoCAD SHX Text

EXISTING ELECTRICAL EQUIPMENT IN THIS AREA TO BE REMOVED UNLESS NOTED OTHERWISE

AutoCAD SHX Text

LIGHTING IN THIS ROOM TO BE REMOVED

AutoCAD SHX Text NOTES: : 1. REFER TO DEMOLITION NOTES ON EP001 AND ARCHITECTURAL REFER TO DEMOLITION NOTES ON EP001 AND ARCHITECTURAL DRAWING 20-AE103 FOR SCOPE OF ADDITIONAL WORK 2. EXISTING POWER AND LIGHTING CIRCUITS TO BE REUSED FOR EXISTING POWER AND LIGHTING CIRCUITS TO BE REUSED FOR NEW EQUIPMENT IN THIS AREA.

AutoCAD SHX Text

AC-20-3

AutoCAD SHX Text

AC-20-4

AutoCAD SHX Text

GROUND BAR (SC-GND-1)

AutoCAD SHX Text

EXISTING LIGHTING, RECIRCUIT FOR THE REDUCTION TO TWO FIXTURES

AutoCAD SHX Text RELOCATE EXISTING TR ROOM POWER DROPS TO NEW LOCATION OF RACKS. PROVIDE NEW MATCHING RECEPTACLES

AutoCAD SHX Text

EXISTING ELECTRICAL PANELS

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 20 - BASEMENT FLOOR ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 4'

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 20 - SECOND FLOOR TR ROOM ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 2'

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 20 - SECOND FLOOR TR ROOM ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 2'

AutoCAD SHX Text PANEL NOTES: 1. ALL CIRCUITS 150V TO GROUND AND 50 AMPS OR LESS ALL CIRCUITS 150V TO GROUND AND 50 AMPS OR LESS SUPPLYING EXTERIOR, BASEMENT, WET OR DAMP LOCATIONS SHALL BE PROVIDED WITH GROUND FAULT CIRCUIT PROTECTION PER NEC ARTICLE 210.8. THE REQUIREMENT INCLUSE RECEPTACLES, AIR CONDITIONING AND CONDENSING UNITS.

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text BUILDING No. 20 - FIRST FLOOR TR ROOM ELECTRICAL PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

F

F F

F

FA

CP

CR

CR

CR CR

JB

JB

JB

JB

M

M

FA

CP

M

TS

PS

FS

M

M

M

JB

JB

CR

F

CR

M

M

M

LIFESAFETY TRANSFER SWITCH

SWITCHBOARD

LIFE SAFETY PANEL

AUTOMATIC

TRANSFER SWITCHES

UNITERRUPTABLE UPS B

TOILET

B-103

CORRIDOR

B-102

IT IMAGING

B-108

STAIR

B-107

OI &T SERVER ROOM

B-106

CRAC-22-1

CRAC-22-2 CRAC-22-3

CRAC-22-4

E22EB-UPSA E22EB-UPSB

E22EB-B2

E22EB-B1

E22LS-ATS

E22EB-ATSA

E22EB-ATSB

22-B1

E22EB-B3

E22LS-B1

E22EB-XFMR

22-XFMR

22-SWBD

UNITERRUPTABLE UPS A

TO E22EB-

UPSA

TO E22EB-

UPSA

TO E22EB-

UPSA

TO E22EB-

UPSB

TO E22EB-

UPSB

TO E22EB-

UPSB

GFI

GFI GFI

GFI

GFI

GFI

GFI

GFI GFI GFI

GFI

GFI

GFI

GFI

TYPICAL 208V POWER BUS100A/3P

100A/3P

E22EB-B2

-1,3,5

E22EB-B2

-2,4,6

100A/3P

100A/3P

E22EB-B1

-1,3,5

E22EB-B1

-2,4,6

LIFE SAFETY

GENERATOR

CONNECTION BOX

E22EB-B3-

6 E22EB-B3-

E22EB-B3-

22-B1- 4

E22EB-B3-

22-B1- 4

22-B1- 4

22-B1- 6

E22EB-B3-

E22EB-B3-

22-B1- 9

22-B1- 8

22-B1- 10

22-B1- 10

E22LS-B1

-10

E22LS-B1

-10

E22LS-B1

-10

FIRE ALARM CONTROL PANEL

DOOR CONTROLLER

(TYPICAL)

WP

WP WP

AC-22-4

EWH-22-1

AC-22-3

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

EXTINGUISHING SYSTEM

CONTROL PANEL

E22LS-B1

-2

SPRINKLER COMPRESSOR

TYPICAL 60A/3P POWER DROP TO EACH

RACK ONE FROM EACH UPS CONSISTING

OF BUS PLUG IN BREAKER, CORD AND

PLUG

GROUND BUS BAR

GROUND BUS BAR

GROUND BUS BAR

CABLE ENTRANCE

22-B109

ELECTRIC ROOM

B-105

GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI

E22EB-B3-

E22EB-B3-

E22EB-B3-

E22EB-B3-

60A

60A

EPO

EPO

EPO

EMERGENCY POWER OFF SWITCH

(TYPICAL AT EACH DOOR) TO SHUT

DOWN UPS UNITS AND SHUNT TRIP

POWER.

KEYED EMERGENCY POWER OFF

SWITCH

TO E22EB-

UPSA

TO E22EB-

UPSB

22-B2

WH-1

E22EB-B2

-20

22-B1 -26,28

AC-22-7

AC-22-8

AC-22-9

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

CABLE ENTRANCE

22-B110

22-B1 -30

E22LS-XFMR

E22LS-B1

-5

E22LS-B1

-5

WP

E22LS-B1

-10

E22LS-B1

-10

EPO

EPO

GFI

GFI

22-B1- 7

22-B1- 7

E22LS-B1

-10

E22EB-B3

-20

E22EB-B3

-21

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

GENERATOR

SET

GFI

GFI

GFI

HAC

TOILET ROOM

22-B1- 11

22-B1- 12

22-B1- 11

AC-22-6

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

22-B1 -19

ERV-22-3

STAIR-1

110-1

CORRIDOR-1

107-1

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

RFK WHH

I:\ 5\

Ac el a

VA

EH

R M

In fra st ru ct ur e

IT

U pg ra de s\ D ra w in gs

\R ev it\

Bl dg

D at ac en te r.r vt

5/

/2

9:

:4

AM

22A-EP101

BUILDING NO. 22A - ELECTRICAL PLANS

06/06/2023

Edward P. Boland VA Medical Ceneter

22A

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN

MASSACHUSETTS

ISSUE FOR BID

SCALE: 1/4" = 1'-0"1 BASEMENT - ELECTRICAL PLAN

SCALE: 1/4" = 1'-0"2 FIRST FLOOR - ELECTRICAL PLAN

Revisions: Date:

M

CR

JB

M

M

M

ERV-22-1

CND-22-2CND-22-1 CND-22-3 CND-22-4

PP-22-4PP-22-3PP-22-2PP-22-1

GFI

WP

GFI

WP

WP

30A/3P

CND-22-1

ROOF PLAN

WP

30A/3P

WP

30A/3P

WP

30A/3P

WP

30A/3P

WP

30A/3P

WP

30A/3P

WP

30A/3P

WP

30A/2PWP

30A/2P

WP

30A/2P

E22EB-B2

-7,9,11

E22EB-B2

-8,10,12

E22EB-B1

-7,9,11

E22EB-B1

-8,10,12

E22EB-B2

-13,15,17

E22EB-B2

-14,16,18

E22EB-B1

-13,15,17

E22EB-B1

-14,16,18

TOILET ROOM

GFI

E22EB-B3

-2,4

E22EB-B3

-8,10 22-B1 -2

22-B1 -2

E22EB-200

-4

E22EB-200

-6

22-B1- 13

E22EB-200

-1,3,5

22-200 -1,3,5

60A

60A

22-B1- 13 3#12, 1#12G 3/4"C

TO CONDENSING UNIT

CU-22-6

CU-22-5

CU-22-4

CU-22-3

CU-22-2

AC-22-5

WP

30A/2P

WP

30A/2P

WP

30A/2P

E22EB-200

-14,16

22-B1 -14,16

22-B1 -15,17

22-B1 -18,20

3#12, 1#12G 3/4"C

TO CONDENSING UNIT

CU-22-7

CU-22-8

CU-22-9

AC-22-1

AC-22-2

CU-22-1

WP

30A/2P

WP

30A/2P

WP

30A/2P

WP

30A/2P

E22EB-B3

-12,14

E22EB-B3

-17,19

E22EB-B3

-16,18

22-200 -14,16

ERV-22-2

GROUND BUS BAR

22-200 -6

22-200 -4

PANEL E22EB-200

PANEL 22-200

TR

CORRIDOR

STAIR

MECHANICAL ROOF LEVEL

HIGH PARAPET

LEVEL LOW LEVEL

ROOF

EXISTINGBUILDING

GAMBREL ROOF

BUILDING RIDGE

ROOF MOUNTED EQUIPMENT

BOND TO LIGHTNING PROTECTION

SYSTEM

DOWNLEADS FROM ROOF

TO BE CONCEALED

GROUND RODS PER NFPA 780

LIGHTNING PROTECTION SYSTEM

POINTS PER NFPA 780

#4/0 AWG GROUND LOOP

AROUND BUILDING

TYPICAL CODWELD

CONNECTION

LIGHTNING PROTECTION SYSTEM NOTES:

1. DRAWINGS ARE PROVIDED AS GUIDES FOR LIGHTNING

PROTECT SYSTEM DESIGNER FINAL DRAWINGS BY

LIGHTNING PROTECTION SYSTEM DESIGN SHALL BE

PROVIDED AFTER FIELD VERIFICATION OF SITE

CONDITIONS. LIGHTNING SYSTEM DESIGNER SHALL

PROVIDE DRAWING AS PART OF SHOP DRAWING

SUBMITTAL, REFER TO SPECIFICATIONS.

2. THE LIGHTNING PROTECTION SYSTEM SHALL BE DESIGNED

PER NFPA 780 AND U.L. MASTER LABELED. LIGHTNING

PROTECTION SYSTEM SHALL BE UL TESTED & INSPECTED.

3. ALL GROUND RODS/SYSTEMS SHOULD MEET THE MIN

RESISTANCE AND TESTED TO MEET NFPA70/780 FOR A

LIGHTNING PROTECTION SYSTEM. THE SYSTEM SHALL BE

TESTED PRIOR TO THE UL INSPECTION.

4. REFER TO ONE-LINE DIAGRAMS FOR SURGE PROTECTIVE

DEVICES (SPD) IS BEING INSTALLED AS PART OF THIS

PROJECT.

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

RFK WHH

I:\ 5\

Ac el a

VA

EH

R M

In fra st ru ct ur e

IT

U pg ra de s\ D ra w in gs

\R ev it\

Bl dg

D at ac en te r.r vt

5/

/2

9:

:4

AM

22A-EP102

BUILDING NO. 22A - SECOND FLOOR ELECTRICAL PLAN

06/06/2023

Edward P. Boland VA Medical Ceneter

22A

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN

MASSACHUSETTS

ISSUE FOR BID

SCALE: 1/4" = 1'-0"1 SECOND FLOOR - ELECTRICAL PLAN

SCALE: 1/8" = 1'-0"2 LIGHTNING PROTECTION PLAN

S

OS

S S

OS

S

OS

A

A

A

A

OI &T SERVER ROOM

B-106

STAIR

B-107

CORRIDOR

B-102

TOILET

B-103

IT IMAGING

B-108

A A A A

22-B1

E22LS-B1

E22EB-B3

AAAA

A A A A

AAAAA

A A A A A

D

D

D

D

EX

EX

EX EX

EX

BB

A A

A

EB

LIGHTING INVERTER

A

EX

E22EB-B3

-9

E22LS-B1

-11

E22LS-B1

-1

E22LS-B1

-4

E22LS-B1

-1

E22LS-B1

-4

E22LS-B1

-1 E22LS-B1

-1

E22LS-B1

-1

E22LS-B1

-1

A A

AA

A A

E22EB-B3

-15

E22EB-B3

-15

NOTES:

1. REFER TO SITE LIGHTING PLAN FOR EXTERIOR LIGHT FIXTURES.

2. PROVIDE LIGHTING CONTACTOR FOR EXTERIOR LIGHTS CONNECTED TO

BUILDING ANAGEMENTS SYSTEM FOR LIGHTING EXTERIOR LIGHTING

CONTROL

22-B1 -21

AA

A A

A

A

E22EB-B3

-15

EX

E22LS-B1

-1

D

D

B

B B

B

TOILET ROOM

HAC

EX

E22LS-B1

-1

E22LS-B1

-4

E22LS-B1

-4

22-B1 -21

D

D

WP

B

B

A

A

EX

TOILET ROOM

B

E22EB-200

E22LS-B1

-1

E22LS-B1

-4

E22LS-B1

-4

22-B1 -22

E22EB-200

-2

22-B1 -21

STAIR

CORRIDOR

TR

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

RFK WHH

I:\ 5\

Ac el a

VA

EH

R M

In fra st ru ct ur e

IT

U pg ra de s\ D ra w in gs

\R ev it\

Bl dg

D at ac en te r.r vt

5/

/2

9:

:5

AM

22A-EP103

BUILDING NO. 22A - LIGHTING PLANS

06/06/2023

Edward P. Boland VA Medical Ceneter

22A

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN

MASSACHUSETTS

ISSUE FOR BID

SCALE: 1/4" = 1'-0"1 BASEMENT - LIGHTING PLAN

SCALE: 1/4" = 1'-0"2 FIRST FLOOR - LIGHTING PLAN

SCALE: 1/4" = 1'-0"3 SECOND FLOOR - LIGHTING PLAN

22A-EP601

BUILDING NO. 22A ONE-LINE

DIAGRAM 22A

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\2 2A

-E P6

B

U

IL

D

IN

G N

O . 2

2A O

N E-

LI

N

E D

IA

G

R

AM

.d w g

1/ 2/

:1

6:

P M

AutoCAD SHX Text

GEN

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text

N.O. TIE BREAKER

AutoCAD SHX Text

MAIN SWITCHBOARD 600A, 480Y/277V 3Ø, 4W, 65 KAIC (NORMAL POWER) 22-SWBD

AutoCAD SHX Text

MULTI-METER

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text N

AutoCAD SHX Text

LIFE SAFETY ATS (LS ATS) 100 AMPERE, 4 POLE, ISOLATION BYPASS

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text N

AutoCAD SHX Text

STANDBY ATS (SB ATS) 600A 4 POLE, ISOLATION BYPASS E22EB-ATSB

AutoCAD SHX Text

PANEL 22-B1

AutoCAD SHX Text 208Y/120V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

225 AMPERE

AutoCAD SHX Text

42 CKT

AutoCAD SHX Text

MM

AutoCAD SHX Text

E22EB-B1

AutoCAD SHX Text 480Y/277V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

600 AMPERE

AutoCAD SHX Text

42 CKT

AutoCAD SHX Text

GENERATOR SET (EMERGENCY POWER) WITH LOAD BANK AND SOUND ATTENUATED ENCLOSURE

AutoCAD SHX Text 350kW DIESEL GENERATOR 480Y/277V 3 , 4W

AutoCAD SHX Text

200AT 200AF

AutoCAD SHX Text TRB22B 500kVA PAD-MOUNTED OIL-FILLED TRANSFORMER 13.8kV 480Y/277V 3 , 4W, 60HZ

AutoCAD SHX Text

(3) LA

AutoCAD SHX Text

FU

AutoCAD SHX Text

FU

AutoCAD SHX Text

200AT 200AF

AutoCAD SHX Text

(3) LA

AutoCAD SHX Text

WP

AutoCAD SHX Text

WP

AutoCAD SHX Text

MM

AutoCAD SHX Text

600AT 600AF

AutoCAD SHX Text

600AT 600AF

AutoCAD SHX Text

30AT

AutoCAD SHX Text

NORMAL POWER

AutoCAD SHX Text

SPD

AutoCAD SHX Text

30AT

AutoCAD SHX Text

SURGE PROTECTIVE DEVICE

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text

600AT 600AF

AutoCAD SHX Text TRB22A 500kVA PAD-MOUNTED OIL-FILLED TRANSFORMER 13.8kV 480Y/277V 3 , 4W, 60HZ

AutoCAD SHX Text

STANDBY ATS (SB ATS) 600A 4 POLE, ISOLATION BYPASS E22EB-ATSA

AutoCAD SHX Text

600AT 600AF

AutoCAD SHX Text

E22EB-B2

AutoCAD SHX Text 480Y/277V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

600 AMPERE

AutoCAD SHX Text

42 CKT

AutoCAD SHX Text

E22LS-B1

AutoCAD SHX Text 208Y/120V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

100 AMPERE

AutoCAD SHX Text

42 CKT

AutoCAD SHX Text

600AT 600AF

AutoCAD SHX Text

25AT 100AF

AutoCAD SHX Text

UPS

AutoCAD SHX Text

480V IN

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

208Y/120V OUT

AutoCAD SHX Text

E22EB-UPSA

AutoCAD SHX Text

150KW

AutoCAD SHX Text

UPS

AutoCAD SHX Text

480V IN

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

208Y/120V OUT

AutoCAD SHX Text

E22EB-UPSB

AutoCAD SHX Text

150KW

AutoCAD SHX Text

AutoCAD SHX Text

NP SCALE

AutoCAD SHX Text

BUILDING NO. 22 - ONE-LINE DIAGRAM

AutoCAD SHX Text

SPARE

AutoCAD SHX Text

SPARE

AutoCAD SHX Text

PANEL 22-200

AutoCAD SHX Text 208Y/120V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

100 AMPERE

AutoCAD SHX Text

30 CKT

AutoCAD SHX Text

45KVA DRY TYPE TRANSFORMER 480V PRIMARY 208Y/120V 3 ,4W SECONDARY 22-XFMR

AutoCAD SHX Text

15KVA DRY TYPE TRANSFORMER 480V PRIMARY 208Y/120V 3 ,4W SECONDARY E22LS-XFMR

AutoCAD SHX Text

E22EB-B3

AutoCAD SHX Text 208Y/120V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

100 AMPERE

AutoCAD SHX Text

30 CKT

AutoCAD SHX Text

30KVA DRY TYPE TRANSFORMER 480V PRIMARY 208Y/120V 3 ,4W SECONDARY E22EB-XFMR

AutoCAD SHX Text

NORMAL POWER

AutoCAD SHX Text

EMERG. POWER

AutoCAD SHX Text

EMERG. POWER

AutoCAD SHX Text

EMERG. POWER

AutoCAD SHX Text

LIFE SAFETY POWER

AutoCAD SHX Text

125AT 200AF

AutoCAD SHX Text

25AT 100AF

AutoCAD SHX Text

225AT 225AF

AutoCAD SHX Text

225AT 225AF

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

WP

AutoCAD SHX Text

MANUAL TRANSFER SWITCH

AutoCAD SHX Text

TEMPORARY GENERATOR CONNECTION TERMINALS

AutoCAD SHX Text

GENERATOR CONNECTION BOX

AutoCAD SHX Text

LOAD BANK AND CONTROLLER

AutoCAD SHX Text

TYPICAL 208V, 3 PHASE BUS BARS

AutoCAD SHX Text

TYPICAL POWER FEED UNIT WITH CURRENT MONITOER TO SUPPORT EACH ROW

AutoCAD SHX Text TYPICAL POWER BUSWAY TAP WITH DUAL BREAKERS AND (2) 3' DROP CORDS WITH STRAIN RELIEF WITH L21-20R EACH REFER TO PLANS FOR QUANTITIES

AutoCAD SHX Text 25A/3P

AutoCAD SHX Text

E22EB-200

AutoCAD SHX Text 208Y/120V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

100 AMPERE

AutoCAD SHX Text

30 CKT

AutoCAD SHX Text KEYNOTES: PROVIDE 16" (UNLESS NOTED OTHERWISE FOR 20") GROUND BUS BAR PER COMMUNICATIONS DRAWINGS AT PANELS AS INDICATED. REFER TO TELECOMMUNICATION DRAWINGS AND DIVISION 27 SPECIFICATIONS

AutoCAD SHX Text

PANEL 22-B2

AutoCAD SHX Text 208Y/120V

AutoCAD SHX Text 3Ø, 4W

AutoCAD SHX Text

100 AMPERE

AutoCAD SHX Text

42 CKT

AutoCAD SHX Text PANEL LOCATED IN BASEMENT OF EXISTING BUILDING EXISTING LOADS TO BE FED FROM PANEL

AutoCAD SHX Text

EMERGENCY POWER OFF SWITCHES

AutoCAD SHX Text NOTES: 1. PROVIDE EMERGENCY POWER OFF SYSTEM PROVIDE EMERGENCY POWER OFF SYSTEM THAT SHUTS OFF POWER TO DATA CENTER, UPS UNITS, DISABLES AUTOMATIC TRANSFER SWITCHES AND SHUNT TRIPS BREAKERS TO UPS UNITS. 2. PROVIDE 200A/3P CIRCUIT BREAKERS IN UPS PROVIDE 200A/3P CIRCUIT BREAKERS IN UPS UNITS TO FEED BUSWAYS AND 60A/3P CIRCUIT BREAKERS FOR CABLE ENTRANCE CLOSETS.

AutoCAD SHX Text

AutoCAD SHX Text

FLOW AND TAMPER SWITCHES FOR SPRINKLER SYSTEM

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text F

AutoCAD SHX Text S

AutoCAD SHX Text F

AutoCAD SHX Text

FIRE ALARM CONTROL PANEL (FACP)

AutoCAD SHX Text F

AutoCAD SHX Text

120VAC, 2#12, 1#12G, 3/4"C

AutoCAD SHX Text

%%UFIRE ALARM WORK NOTES:

AutoCAD SHX Text

1. ACTUAL NUMBER OF SMOKE AND HEAT DETECTORS IS NOT SHOWN. ACTUAL NUMBER OF SMOKE AND HEAT DETECTORS IS NOT SHOWN. REFER TO ELECTRICAL, FIRE PROTECTION AND MECHANICAL PLANS FOR EXACT QUANTITIES. 2. MAXIMUM OF 11 AUDIO/VISUAL DEVICES PER CIRCUIT. MAXIMUM OF 11 AUDIO/VISUAL DEVICES PER CIRCUIT. 3. CORRIDOR AUDIO/VISUAL (STROBE TYPE) NOTIFICATION DEVICES SHALL BE CORRIDOR AUDIO/VISUAL (STROBE TYPE) NOTIFICATION DEVICES SHALL BE SYNCHRONIZED. 4. ALL WIRING SHALL BE IN CONDUIT.ALL WIRING SHALL BE IN CONDUIT.

AutoCAD SHX Text

FIRE ALARM RISER DIAGRAM NO SCALE

AutoCAD SHX Text

FIRE EXINGUISHING SYSTEM CONTROL PANEL

AutoCAD SHX Text

EXISTING BUILDING NO. 22 FIRE ALARM CONTROL PANEL (FACP)

AutoCAD SHX Text

120VAC, 2#12, 1#12G, 3/4"C

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

RFK WHH

I:\ 5\

Ac el a

VA

EH

R M

In fra st ru ct ur e

IT

U pg ra de s\ D ra w in gs

\R ev it\

Bl dg

D at ac en te r.r vt

5/

/2

9:

:4

AM

22A-EP602

BUILDING NO. 22A - PANEL SCHEDULES

06/06/2023

Edward P. Boland VA Medical Ceneter

22A

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN

MASSACHUSETTS

ISSUE FOR BID

Notes:

Total Est. Demand: 66 A Receptacle 10400 VA 98.08% 10200 VA Total Conn.: 67 A Other 0 VA 0.00% 0 VA Total Est. Demand: 23791 VA Lighting 270 VA 100.00% 270 VA Total Conn. Load: 23991 VA

HVAC 13328 VA 100.00% 13328 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 80 A 77 A 50 A Total Load: 9195 VA 8788 VA 6009 VA

-- -- SPARE 1 20 A 41 0 VA 0 VA 42 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 39 0 VA 0 VA 40 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 37 0 VA 0 VA 38 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 35 0 VA 0 VA 36 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 33 0 VA 0 VA 34 20 A 1 SPARE -- --

31 0 VA 32 20 A 1 SPARE -- --

29 720 VA 30 20 A 1 Receptacle CABLE ENTRANCE... 1-#12, 1-#12, 1-#12

27 0 VA 2250 VA 28

25 0 VA 2250 VA 26

30 A 2 WH-1 3/4" 2-#10, 1-#10, 1-#10

3-#1, 1-#1, 1-#8 2" panel 22-B2 3 100 A

23 0 VA 0 VA 24 20 A 1 SPARE -- --

1-#12, 1-#12, 1-#12 3/4" Lighting Room 22-B103, 22-B104 1 20 A 21 258 VA 13 VA 22 20 A 1 Lighting 3/4" 1-#12, 1-#12, 1-#12

1-#12, 1-#12, 1-#12 3/4" HVAC JANITOR 22-108 1 20 A 19 670 VA 936 VA 20

17 936 VA 936 VA 18

20 A 2 CU-22-3 3/4" 2-#12, 1-#12, 1-#12

2-#12, 1-#12, 1-#12 3/4" CU-22-4 2 20 A

15 936 VA 936 VA 16

1-#12, 1-#12, 1-#12 3/4" Receptacle TR-1 22-203-1 1 20 A 13 360 VA 936 VA 14

20 A 2 CU-22-5 3/4" 2-#12, 1-#12, 1-#12

1-#12, 1-#12, 1-#12 3/4" Receptacle Room 22-108, 22-106 1 20 A 11 360 VA 180 VA 12 20 A 1 Receptacle TOILET ROOM 22-107 3/4" 1-#12, 1-#12, 1-#12 1-#12, 1-#12, 1-#12 3/4" Receptacle HAC 22-B104 1 20 A 9 180 VA 360 VA 10 20 A 1 Receptacle Room 22-B107, 22-B102 3/4" 1-#12, 1-#12, 1-#12 1-#12, 1-#12, 1-#12 3/4" Receptacle ELECTRIC ROOM... 1 20 A 7 720 VA 180 VA 8 20 A 1 Receptacle TOILET 22-B103 3/4" 1-#12, 1-#12, 1-#12

5 2337 VA 540 VA 6 20 A 1 Receptacle OI&T SERVER ROOM... 3/4" 1-#12, 1-#12, 1-#12 3 3323 VA 540 VA 4 20 A 1 Receptacle OI&T SERVER ROOM... 3/4" 1-#12, 1-#12, 1-#123-#1, 1-#1, 1-#8 2" 22-200 3 100 A 1 2603 VA 540 VA 2 20 A 1 Receptacle 3/4" 1-#12, 1-#12, 1-#12

WIRE SIZE

(H,N,G) CONDUIT Load Name POLE AMP CKT

No

A B C A B C CKT

No AMP POLE Load Name CONDUIT WIRE SIZE

(H,N,G)

Enclosure: Type 1 Mounting: Recessed Wires: 4 MCB Rating: 150 A

Supply From: 22-XFMR Phases: 3 Mains Type: MCB Location: Volts: 120/208 Wye A.I.C. Rating: 22 KAIC

Panel: 22-B1

1. PROVIDE E22EB-UPSB CIRCUIT BREAKER WITH LSI SEETINGS AND SHUNT TRIP FOR EMERGEBCY POWER OFF Notes:

Total Est. Demand: 308 A Receptacle 8420 VA 100.00% 8420 VA Total Conn.: 308 A Lighting 1200 VA 100.00% 1200 VA Total Est. Demand: 256011 VA HVAC 96451 VA 100.00% 96451 VA Total Conn. Load: 256011 VA Equipment 150000 VA 100.00% 150000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 312 A 310 A 304 A Total Load: 86304 VA 85637 VA 84071 VA

41 50000... -- 42 -- 1 SPACE -- --

39 50000 VA -- 40 -- 1 SPACE -- --3-#4/0, 1-#4/0, 1-#4 3" E22EB-UPSA 3 225 A

37 50000... -- 38 -- 1 SPACE -- --

-- -- SPARE 1 20 A 35 0 VA -- 36 -- 1 SPACE -- --

-- -- SPARE 1 20 A 33 0 VA -- 34 -- 1 SPACE -- --

-- -- SPARE 1 20 A 31 0 VA -- 32 -- 1 SPACE -- --

-- -- SPARE 1 20 A 29 0 VA -- 30 -- 1 SPACE -- --

-- -- SPARE 1 20 A 27 0 VA -- 28 -- 1 SPACE -- --

-- -- SPARE 1 20 A 25 0 VA -- 26 -- 1 SPACE -- --

23 5375 VA -- 24 -- 1 SPACE -- --

21 6948 VA -- 22 -- 1 SPACE -- --3-#6, 1-#6, 1-#10 1" E22EB-XFMR 3 50 A

19 7607 VA -- 20 -- 1 SPACE -- --

17 942 VA 942 VA 18

15 942 VA 942 VA 163-#12, 1-#12 3/4" PP-22-3 3 15 A

13 942 VA 942 VA 14

15 A 3 PP-22-4 3/4" 3-#12, 1-#12

11 1247 VA 1247 VA 12

9 1247 VA 1247 VA 103-#12, 1-#12 3/4" CND-22-3 3 15 A

7 1247 VA 1247 VA 8

15 A 3 CND-22-4 3/4" 3-#12, 1-#12

5 12160... 12160... 6

3 12160 VA 12160 VA 43-#4, 1-#8 1 1/4" CRAC-22-3 3 70 A

1 12160... 12160... 2

70 A 3 CRAC-22-4 1 1/4" 3-#4, 1-#8

WIRE SIZE

(H,N,G) CONDUIT Load Name POLE AMP CKT

No

A B C A B C CKT

No AMP POLE Load Name CONDUIT WIRE SIZE

(H,N,G)

Enclosure: 1 Mounting: Surface Wires: 4 Mains Rating: 600 A

Supply From: 22-SWBD Phases: 3 Mains Type: MLO Location: Volts: 480/277 Wye A.I.C. Rating: 22 KAIC

Panel: E22EB-B1

1. PROVIDE E22EB-UPSB CIRCUIT BREAKER WITH LSI SEETINGS AND SHUNT TRIP FOR EMERGEBCY POWER OFF Notes:

Total Est. Demand: 286 A Total Conn.: 286 A

Total Est. Demand: 238090 VA HVAC 88090 VA 100.00% 88090 VA Total Conn. Load: 238090 VA Equipment 150000 VA 100.00% 150000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 291 A 284 A 284 A Total Load: 80697 VA 78697 VA 78697 VA

41 50000... -- 42 -- 1 SPACE -- --

39 50000 VA -- 40 -- 1 SPACE -- --3-#4/0, 1-#4/0, 1-#4 3" E22EB-UPSB 3 225 A

37 50000... -- 38 -- 1 SPACE -- --

-- -- SPACE 1 -- 35 -- -- 36 -- 1 SPACE -- --

-- -- SPACE 1 -- 33 -- -- 34 -- 1 SPACE -- --

-- -- SPACE 1 -- 31 -- -- 32 -- 1 SPACE -- --

-- -- SPACE 1 -- 29 -- -- 30 -- 1 SPACE -- --

-- -- SPACE 1 -- 27 -- -- 28 -- 1 SPACE -- --

-- -- SPACE 1 -- 25 -- -- 26 -- 1 SPACE -- --

-- -- SPACE 1 -- 23 -- -- 24 -- 1 SPACE -- --

-- -- SPACE 1 -- 21 -- -- 22 -- 1 SPACE -- --

19 2000 VA 20 20 A 1 HVAC 3/4" 1-#12, 1-#12, 1-#12

17 942 VA 942 VA 18

15 942 VA 942 VA 163-#12, 1-#12 3/4" PP-22-1 3 15 A

13 942 VA 942 VA 14

15 A 3 PP-22-2 3/4" 3-#12, 1-#12

11 1247 VA 1247 VA 12

9 1247 VA 1247 VA 103-#12, 1-#12 3/4" CND-22-1 3 15 A

7 1247 VA 1247 VA 8

15 A 3 CND-22-2 3/4" 3-#12, 1-#12

5 12160... 12160... 6

3 12160 VA 12160 VA 43-#4, 1-#8 1 1/4" CRAC-22-1 3 70 A

1 12160... 12160... 2

70 A 3 CRAC-22-2 1 1/4" 3-#4, 1-#8

WIRE SIZE

(H,N,G) CONDUIT Load Name POLE AMP CKT

No

A B C A B C CKT

No AMP POLE Load Name CONDUIT WIRE SIZE

(H,N,G)

Enclosure: 1 Mounting: Surface Wires: 4 Mains Rating: 600 A

Supply From: 22-SWBD Phases: 3 Mains Type: MLO Location: Volts: 480/277 Wye A.I.C. Rating: 22 KAIC

Panel: E22EB-B2

1. PROVIDE WITH LSI TRIP UNIT ON MAIN BREAKER.

Notes:

Total Est. Demand: 55 A Total Conn.: 55 A

Receptacle 8420 VA 100.00% 8420 VA Total Est. Demand: 19925 VA Lighting 1200 VA 100.00% 1200 VA Total Conn. Load: 19925 VA

HVAC 10361 VA 100.00% 10361 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 65 A 60 A 45 A Total Load: 7607 VA 6948 VA 5375 VA

-- -- SPACE 1 -- 41 -- -- 42 -- 1 SPACE -- --

-- -- SPACE 1 -- 39 -- -- 40 -- 1 SPACE -- --

-- -- SPACE 1 -- 37 -- -- 38 -- 1 SPACE -- --

-- -- SPACE 1 -- 35 -- -- 36 -- 1 SPACE -- --

-- -- SPACE 1 -- 33 -- -- 34 -- 1 SPACE -- --

-- -- SPACE 1 -- 31 -- -- 32 -- 1 SPACE -- --

-- -- SPACE 1 -- 29 -- -- 30 -- 1 SPACE -- --

-- -- SPARE 1 20 A 27 0 VA 0 VA 28 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 25 0 VA 0 VA 26 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 23 0 VA 0 VA 24 20 A 1 SPARE -- --

1-#12, 1-#12, 1-#12 3/4" Receptacle IT IMAGING B-108 1 20 A 21 180 VA 0 VA 22 20 A 1 SPARE -- -- 19 936 VA 180 VA 20 20 A 1 Receptacle IT IMAGING B-108 3/4" 1-#12, 1-#12, 1-#122-#12, 1-#12, 1-#12 3/4" Power 2 20 A

17 936 VA 936 VA 18

1-#12, 1-#12, 1-#12 3/4" Lighting 1 20 A 15 480 VA 936 VA 16 20 A 2 Power 3/4" 2-#12, 1-#12, 1-#12

1-#12, 1-#12, 1-#12 3/4" Receptacle CABLE ENTRANCE... 1 20 A 13 720 VA 936 VA 14 1-#12, 1-#12, 1-#12 3/4" Lighting 1 20 A 11 0 VA 936 VA 12

20 A 2 Power 3/4" 2-#12, 1-#12, 1-#12

1-#12, 1-#12, 1-#12 3/4" Lighting 1 20 A 9 640 VA 937 VA 10 1-#12, 1-#12, 1-#12 3/4" Receptacle OI&T SERVER ROOM... 1 20 A 7 720 VA 937 VA 8

20 A 2 CU-22-2 3/4" 2-#12, 1-#12

5 1847 VA 720 VA 6 20 A 1 Receptacle OI&T SERVER ROOM... 3/4" 1-#12, 1-#12, 1-#12

3 3323 VA 500 VA 43-#1, 1-#1, 1-#8 2" PANEL E22EB-200 3 100 A

1 2679 VA 500 VA 2

20 A 2 ERV-22-1 3/4" 2-#12, 1-#12

WIRE SIZE

(H,N,G) CONDUIT Load Name POLE AMP CKT

No

A B C A B C CKT

No AMP POLE Load Name CONDUIT WIRE SIZE

(H,N,G)

Enclosure: Type 1 Mounting: Recessed Wires: 4 Mains Rating: 100 A

Supply From: E22EB-XFMR Phases: 3 Mains Type: MLO Location: Volts: 120/208 Wye A.I.C. Rating: 22 KAIC

Panel: E22EB-B3

1. PROVIDE WITH LSI TRIP UNIT ON MAIN BREAKER

Notes:

Receptacle 1080 VA 100.00% 1080 VA Total Est. Demand: 10 A Other 279 VA 100.00% 279 VA Total Conn.: 10 A Lighting - Exterior 100 VA 125.00% 125 VA Total Est. Demand: 3724 VA Lighting 1146 VA 100.00% 1146 VA Total Conn. Load: 3700 VA

HVAC 1130 VA 100.00% 1130 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 10 A 12 A 9 A Total Load: 1138 VA 1485 VA 1094 VA

-- -- SPACE 1 -- 29 -- -- 30 -- 1 SPACE -- --

-- -- SPACE 1 -- 27 -- -- 28 -- 1 SPACE -- --

-- -- SPACE 1 -- 25 -- -- 26 -- 1 SPACE -- --

-- -- SPACE 1 -- 23 -- -- 24 -- 1 SPACE -- --

-- -- SPACE 1 -- 21 -- -- 22 -- 1 SPACE -- --

-- -- SPARE 1 20 A 19 0 VA 0 VA 20 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 17 0 VA 0 VA 18 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 15 0 VA 0 VA 16 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 13 0 VA 0 VA 14 20 A 1 SPARE -- --

1-#12, 1-#12, 1-#12 3/4" Lighting 1 20 A 11 360 VA 465 VA 12 20 A 1 Exterior Lighting 1" 1-#12, 1-#12, 1-#12 -- -- SPARE 1 20 A 9 0 VA 1080 VA 10 20 A 1 FIRE ALARM CONTROL PANEL 3/4" 1-#12, 1-#12, 1-#12

-- -- SPARE 1 20 A 7 0 VA 0 VA 8 20 A 1 SPARE -- --

1-#12, 1-#12, 1-#12 3/4" Other OI&T SERVER ROOM 22-B106 1 20 A 5 200 VA 100 VA 6 20 A 1 Exterior Lighting 1" 1-#12, 1-#12, 1-#12 1-#12, 1-#12, 1-#12 1" Exterior Lighting 1 20 A 3 57 VA 359 VA 4 20 A 1 Lighting Room 22-109, 22-106 3/4" 1-#12, 1-#12, 1-#12 1-#12, 1-#12, 1-#12 3/4" Lighting STAIR 22-B107 1 20 A 1 8 VA 1130 VA 2 20 A 1 SPRINKLER AIR COMPRESSOR 3/4" 1-#12, 1-#12, 1-#12

WIRE SIZE

(H,N,G) CONDUIT Load Name POLE AMP CKT

No

A B C A B C CKT

No AMP POLE Load Name CONDUIT WIRE SIZE

(H,N,G)

Enclosure: Type 1 Mounting: Recessed Wires: 4 MCB Rating: 50 A

Supply From: Phases: 3 Mains Type: MCB Location: Volts: 120/208 Wye A.I.C. Rating: 22KAIC

Panel: E22LS-B1

Notes:

Total Est. Demand: 23 A Total Conn.: 23 A

Total Est. Demand: 8262 VA Receptacle 5720 VA 100.00% 5720 VA Total Conn. Load: 8262 VA

HVAC 2542 VA 100.00% 2542 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 22 A 28 A 19 A Total Load: 2603 VA 3323 VA 2337 VA

-- -- SPACE 1 -- 29 -- 0 VA 30

-- -- SPACE 1 -- 27 -- 0 VA 28

-- -- SPACE 1 -- 25 -- 0 VA 26

30 A 3 SURGE PROTECTIVE DEVICE -- --

23 0 VA -- 24 -- 1 SPACE -- --

21 0 VA -- 22 -- 1 SPACE -- ---- -- SPARE 3 60 A

19 0 VA -- 20 -- 1 SPACE -- --

17 0 VA -- 18 -- 1 SPACE -- --

15 0 VA 936 VA 16-- -- SPARE 3 30 A

13 0 VA 936 VA 14 20 A 2 Power 3/4" 2-#12, 1-#12, 1-#12

11 0 VA 0 VA 12 20 A 1 SPARE -- --

9 0 VA 0 VA 10 20 A 1 SPARE -- ---- -- SPARE 3 30 A

7 0 VA 0 VA 8 20 A 1 SPARE -- --

5 1667 VA 670 VA 6 20 A 1 ERV-22-2 HVAC TR 146 1-#12, 1-#12, 1-#12

3 1667 VA 720 VA 4 20 A 1 Receptacle TR 22-207 3/4" 1-#12, 1-#12, 1-#123-#4, 1-#4, 1-#10 1 1/4" Receptacle TR-2 22-203-2 3 60 A

1 1667 VA 0 VA 2 20 A 1 SPARE -- --

WIRE SIZE

(H,N,G) CONDUIT DESCRIPTION POLE AMP CKT

No

A B C A B C CKT

No

AMP POLE DESCRIPTION CONDUIT WIRE SIZE

(H,N,G)

Enclosure: Type 1 Mounting: Surface Wires: 4 Mains Rating: 100 A

Supply From: 22-B1 Phases: 3 Mains Type: MLO Location: TR 146 Volts: 120/208 Wye A.I.C. Rating: 22 KAIC

Panel: 22-200

Notes:

Total Est. Demand: 22 A Total Conn.: 22 A

Receptacle 5900 VA 100.00% 5900 VA Total Est. Demand: 7848 VA Lighting 80 VA 100.00% 80 VA Total Conn. Load: 7848 VA

HVAC 1872 VA 100.00% 1872 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 23 A 29 A 15 A Total Load: 2679 VA 3323 VA 1847 VA

-- -- SPACE 1 -- 29 -- 30

-- -- SPACE 1 -- 27 -- 0 VA 28

-- -- SPACE 1 -- 25 -- 0 VA 26

23 0 VA 0 VA 24

30 A 3 SURGE PROTECTIVE DEVICE -- --

21 0 VA 0 VA 22 20 A 1 SPARE -- ---- -- SPARE 3 60 A

19 0 VA 0 VA 20 20 A 1 SPARE -- --

17 0 VA 0 VA 18 20 A 1 SPARE -- --

15 0 VA 936 VA 16-- -- SPARE 3 30 A

13 0 VA 936 VA 14 20 A 2 CU-22-1 3/4" 2-#12, 1-#12

11 0 VA 0 VA 12 20 A 1 SPARE -- --

9 0 VA 0 VA 10 20 A 1 SPARE -- ---- -- SPARE 3 30 A

7 0 VA 0 VA 8 20 A 1 SPARE -- --

5 1667 VA 180 VA 6 20 A 1 Receptacle TR-2 22-203-2 3/4" 1-#12, 1-#12, 1-#12 3 1667 VA 720 VA 4 20 A 1 Receptacle TR 22-207 3/4" 1-#12, 1-#12, 1-#123-#4, 1-#4, 1-#10 1 1/4" Receptacle TR-2 22-203-2 3 60 A 1 1667 VA 80 VA 2 20 A 1 Lighting Room 22-203 3/4" 1-#12, 1-#12, 1-#12

WIRE SIZE

(H,N,G) CONDUIT DESCRIPTION POLE AMP CKT

No

A B C A B C CKT

No

AMP POLE DESCRIPTION CONDUIT WIRE SIZE

(H,N,G)

Enclosure: Type 1 Mounting: Surface Wires: 4 Mains Rating: 100 A

Supply From: E22EB-B3 Phases: 3 Mains Type: MLO Location: TR 146 Volts: 120/208 Wye A.I.C. Rating: 22 KAIC

Panel: E22EB-200

1. FIELD LOCATE PANEL IN EXISTING BUILDING AND CONNECT EXISTING CIRCUITS TO PANEL EXTEND WIRE/CONDUIT TO NEW LOCATION. FIELD VERIFY CIRCUIT BREAKER

REQUIREMENTS IN FIELD..

Notes:

Total Est. Demand: 0 A Total Conn.: 0 A

Total Est. Demand: 0 VA Total Conn. Load: 0 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps: 0 A 0 A 0 A Total Load: 0 VA 0 VA 0 VA

41 0 VA 0 VA 42

-- -- SPARE 2 30 A

39 0 VA 0 VA 40

30 A 2 SPARE -- --

-- -- SPARE 1 20 A 37 0 VA 0 VA 38 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 35 0 VA 0 VA 36 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 33 0 VA 0 VA 34 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 31 0 VA 0 VA 32 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 29 0 VA 0 VA 30 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 27 0 VA 0 VA 28 20 A 1 SPARE -- --

-- -- SPARE 1 20 A 25 0 VA 0 VA 26 20 A 1 SPARE -- --

-- -- EXISTING LOAD 1 20 A 23 0 VA 0 VA 24 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 21 0 VA 0 VA 22 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 19 0 VA 0 VA 20 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 17 0 VA 0 VA 18 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 15 0 VA 0 VA 16 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 13 0 VA 0 VA 14 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 11 0 VA 0 VA 12 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 9 0 VA 0 VA 10 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 7 0 VA 0 VA 8 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 5 0 VA 0 VA 6 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 3 0 VA 0 VA 4 20 A 1 EXISTING LOAD -- --

-- -- EXISTING LOAD 1 20 A 1 0 VA 0 VA 2 20 A 1 EXISTING LOAD -- --

WIRE SIZE

(H,N,G) CONDUIT Load Name POLE AMP CKT

No

A B C A B C CKT

No AMP POLE Load Name CONDUIT WIRE SIZE

(H,N,G)

Enclosure: Type 1 Mounting: Recessed Wires: 4 MCB Rating: 150 A

Supply From: 22-B1 Phases: 3 Mains Type: MCB Location: Volts: 120/208 Wye A.I.C. Rating:

Panel: 22-B2

S

S

ONEWAY SIGN

LIGHT POLE

LIGHT POLE

LIGHT POLE

LIGHT POLE

STOP SIGN

#1 W

-A

#1 E-

A

#1C

#2

#22

LIGHT POLE

LIGHT POLE

LIGHT POLE

FRONT HILL ROAD

E

E

S

S

S

S

S

MM

M E

D M

M

E E E

BOLLARDS

(TYP.)

STONE

WALL

SSWR-MH SSWR-MH

SSWR-MH

SSWR-MH

TG:

393.62

(SILTED)

TG:

393.77

(SILTED)

D

BRICK

BUILDING

M M

CONC PAD

FOR TANKS

UST VENT

CONC. DRAIN

CONC.

DRAIN

HVAC

S

HC

RAMP

CONC.

WALK &

STEPS

HVAC

CONC.

VAULT

HVACPORCHBLDG

OVERHANG

BLDG

OVERHANG

BLDG

OVERHANG

WINGWALL

BLDG

OVERHANG

E

C

S

E

E

C

RIM:

406.77

S

D D

D

D

S

D

SSWR-MH

RIM:

372.21

CONC.

VAULT

SAWCUT

SA

W

CU

T

RET WALL

CONC SW

BITUM PAVING

BIT

UM

PA

VIN

G

BITUM PAVING

S

PIPEVENT

S

S

ST

ST

BURIED

(GRAVEL)

ST

N81°49'18"E 690.00'

S60°10'42"E 670.00'

STEAM (ABANDONED)

X

X

SAN

SAN

SAN

S

S

SAN

SAN

X

SAN

SA

N

E.

O

.P

GRANITE CURB

2+00

2+40

0+

0+

PROP. 2'X2' CB- 22

TG: 388.5

INV. OUT: 385.5

12" HDPE

CONNECT TO

EXISTING CATCH BASIN

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

22A-ESS101

BUILDING NO. 22A - ELECTRICAL

SITE PLAN 22A

W.H.H. E.J.D.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

ISSUE FOR BIDOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

621-21-700

Project Director

06/06/ 2023Revisions: Date:

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Edward P. VA Medical Center

I:\ 5\

A ce la

V A

EH

R

M In fra st ru ct ur e

IT

U pg ra de s\

D ra w in gs \E le ct ric al

\2 2A

-E

SS

BU

IL

D

IN

G N

O . 2

2A

EL

EC

TR

IC

AL

S

IT

E

PL

AN

.d w g

1/ 2/

4:

:3

PM

AutoCAD SHX Text

WV

AutoCAD SHX Text

EBOX

AutoCAD SHX Text

GAS

AutoCAD SHX Text

MET

AutoCAD SHX Text

EBOX

AutoCAD SHX Text

EBOX

AutoCAD SHX Text

EBOX

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING SWITCH SW8

AutoCAD SHX Text

EXISTING SWITCH SW9

AutoCAD SHX Text

NEW PAD MOUNTED TRANSFORMER TRB22A

AutoCAD SHX Text

NEW PAD MOUNTED TRANSFORMER TRB22B

AutoCAD SHX Text

BUILDING 22

AutoCAD SHX Text

NEW GENERATOR SET ON CONCRETE PAD

AutoCAD SHX Text

TR

AutoCAD SHX Text

ESS502

AutoCAD SHX Text

TR

AutoCAD SHX Text

ESS502

AutoCAD SHX Text

4 WAY

AutoCAD SHX Text

6 WAY

AutoCAD SHX Text

EXISTING LIGHT TO BE REMOVED

AutoCAD SHX Text

TR

AutoCAD SHX Text

ESS502

AutoCAD SHX Text

4 WAY

AutoCAD SHX Text

TR

AutoCAD SHX Text

ESS502

AutoCAD SHX Text

2 WAY

AutoCAD SHX Text CONNECT MEDIUM VOLTAGE CABLES IN VAULT TO EXISTING 15KV SWITCH REFER TO ONE-LINE DRAWING EP601

AutoCAD SHX Text

CE

AutoCAD SHX Text

ESS504

AutoCAD SHX Text

CONDUIT ENTRY AT MANHOLE

AutoCAD SHX Text

GND

AutoCAD SHX Text

ESS501

AutoCAD SHX Text

TR

AutoCAD SHX Text

ESS504

AutoCAD SHX Text CONNECT MEDIUM VOLTAGE CABLES IN VAULT TO EXISTING 15KV SWITCH REFER TO ONE-LINE DRAWING EP601

AutoCAD SHX Text

CE

AutoCAD SHX Text

ESS504

AutoCAD SHX Text

CONDUIT ENTRY AT MANHOLE

AutoCAD SHX Text

NEW MV SWITCH SW22

AutoCAD SHX Text

SW22

AutoCAD SHX Text

PROVIDE 2 BOLLARDS AT SWITCH SW22 AT EACH CORNER

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1" = 30'-0"

AutoCAD SHX Text

BUILDING NO 22 - ELECTRICAL SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text 30'

AutoCAD SHX Text 60'

AutoCAD SHX Text

E22LS-B1

-3

E22LS-B1

-6

E22LS-B1

-12

EXF-6

EXF-6

EXF-6

EXF-6

EXF-6

EXF-1 EXF-1

EXF-1

EXF-2

EXF-2

EXF-2

EXF-2 EXF-2

EXF-2

EXF-2

EXF-2

EXF-2

EXF-2

EXF-2

EXF-2

EXF-4

EXF-5

E22LS-B1

-12

VIA LIGHTING

CONTACTR

VIA LIGHTING

CONTACTR

VIA LIGHTING

CONTACTR

VIA LIGHTING

CONTACTR

NEW DATA CENTER

BUILDING NO. 22

POLE MOUTED SITE

LIGHT

MOUNT LIGHT

FIXTURE

ABOVE DOOR

TYPICAL BOLLARD WITH

CONCRETE BASE

GENERATOR SET

PAD MOUNTED

TRANSFORMERS

MOUNTED ON

EXISTING BUILDING

T3

EXF-2 EXF-2 EXF-2

E22LS-B1

-12

E22LS-B1

E22EB-B3

22-B1

© Copyright 2022 DuBois & King Inc.

85 MAIN STREET

SPRINGFIELD, VT 05156

TEL: (802) 591-4326

FAX: (866) 783-7101

www.dubois-king.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

RFK WHH

I:\ 5\

Ac el a

VA

EH

R M

In fra st ru ct ur e

IT

U pg ra de s\ D ra w in gs

\R ev it\

Bl dg

D at ac en te r.r vt

5/

/2

9:

:5

AM

22A-ESS102

BUILDING NO. 22A - SITE LIGHTING PLAN

06/06/2023

Edward P. Boland VA Medical Ceneter

22A

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL…

This is the start of the file's text. The full file is on GovTribe.