S02 - ATTACHMENT 21 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 13.pdf

PDF 16 MB Posted

Attached to
EHRM Infrastructure Upgrades Construction - Central Western Massachusetts Federal contract opportunity
Solicitation number
36C77623R0051
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document provides details for a federal construction contract opportunity issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation seeks construction services for infrastructure upgrades at central western Massachusetts veterans healthcare facilities. Offerors are to complete upgrades to electrical, mechanical, and structural systems. The fixed price design-build contract, numbered 36C77623R0051, has an estimated value of $25-50 million. Proposals are due by January 15, 2023, with work to be completed within 24 months of award. The opportunity is open to all responsible sources and has no set-aside provisions.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Infrastructure Upgrades Construction - Central Western Massachusetts, newest first.
File Type Posted
36C77623R0051 0006 - CWM EHRM - RFIs Cont and Language.pdf PDF
Technical Questions Cont. - CWM EHRM.pdf PDF
Attachment 5 - GC402-REVISED_07_19_2023_ADDENDUM2.pdf PDF
Attachment 3 - BASEMENT LEVEL ELECTRICAL PLAN - WEST - LIBERTY BLDG.pdf PDF
36C77623R0051 0005 - EHRM CWM - Extension and RFIs.pdf PDF
Attachment 1 - Technical Questions - CWM EHRM VA Response.pdf PDF
Attachment 2 - EHRM CWM - Geotechnical Engineering Report.pdf PDF
Attachment 4 - BASEMENT LEVEL ELECTRICAL PLAN - EAST - LIBERTY BLDG.pdf PDF
Attachment 6 - 1-AE120-REVISED_07_19_2023_ADDENDUM2.pdf PDF
Site Visit 2 Sign-in Sheet - CWM EHRM.pdf PDF
Site Visit 2 Sign-in Sheet - CWM EHRM.pdf PDF
36C77623R0051 0004 - EHRM CWM.pdf PDF
Updated Book 1.pdf PDF
Updated Book 3.pdf PDF
EHRM EP601 Addendum 1 6-15-2023 .pdf PDF
Second Site Visit Instructions.pdf PDF
36C77623R0051 0003 - CWM - Second Site Visit and Extension of RFIs.pdf PDF
36C77623R0051 0002 - CWM EHRM - Extend Deadline for RFIs.pdf PDF
Site Visit Sign In Sheet - Central Western Massachusetts.pdf PDF
36C77623R0051 0001 - CWM Sign In Sheet.pdf PDF
S02 - Solicitation - 36C77623R0051 - CWM EHRM.pdf PDF
S02 - ATTACHMENT 2 - SPEC BOOK 2.pdf PDF
S02 - ATTACHMENT 7 - COMBINED-MEP_FP_IT_06012023_Part3.pdf PDF
S02 - ATTACHMENT 8 - COMBINED-MEP_FP_IT_06012023_Part4.pdf PDF
S02 - ATTACHMENT 10 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 2.pdf PDF
S02 - ATTACHMENT 12 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 4.pdf PDF
S02 - ATTACHMENT 14 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 6.pdf PDF
S02 - ATTACHMENT 24 - Contractor Safety - Environmental Form.pdf PDF
S02 - ATTACHMENT 26 - Hampshire County Wage Rates 03.31.2023.pdf PDF
S02 - ATTACHMENT 27 - Site Visit Instructions.pdf PDF
S02 - ATTACHMENT 17 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 9.pdf PDF
S02 - ATTACHMENT 3 - SPEC BOOK 3.pdf PDF
S02 - ATTACHMENT 4 - SPEC BOOK 4.pdf PDF
S02 - ATTACHMENT 13 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 5.pdf PDF
S02 - ATTACHMENT 9 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 1.pdf PDF
S02 - ATTACHMENT 1 - SPEC BOOK 1.pdf PDF
S02 - ATTACHMENT 6 - COMBINED-MEP_FP_IT_06012023_Part2.pdf PDF
S02 - ATTACHMENT 15 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 7.pdf PDF
S02 - ATTACHMENT 22 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 14.pdf PDF
S02 - ATTACHMENT 23 - Brand Name Justification - CWM EHRM - Redacted.pdf PDF
S02 - ATTACHMENT 25 - Limitations on Subcontracting.pdf PDF
S02 - ATTACHMENT 5 - COMBINED-MEP_FP_IT_06012023_Part1.pdf PDF
S02 - ATTACHMENT 11 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 3.pdf PDF
S02 - ATTACHMENT 16 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 8.pdf PDF
S02 - ATTACHMENT 18 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 10.pdf PDF
S02 - ATTACHMENT 19 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 11.pdf PDF
S02 - ATTACHMENT 20 - COMBINED-ARCH_CIVIL_STRUCTURAL_PART 12.pdf PDF
Show all 47

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

BUILDING 3

N O

R

TH

AM

PTO

N

T11

13S

9A

N

141 SF

TR

3-218

206 205

224A

224B

231232

215 216

PATH OF EGRESS

TRAVEL = 26' - 4"

3-220

2HR 2HR

2HR

2HR

SM

2HR

2HR

2HR

2HR2HR 2HR

2HR2HR

2HR2HR

2HR

2HR

SM

SM

142 SF

TR

3-120

80 SF

HAC

3-124

106 105

107 108

117 118 119

136A

3-122

127A

135A

PATH OF EGRESS TRAVEL = 31' - 6"PATH OF EGRESS

TRAVEL = 26' - 7"

2HR2HR

2HR

2HR

SM

SM

SM

2HR

2HR

2HR

2HR2HR

2HR 2HR 2HR

2HR2HR

2HR

2HR

FIRE RATING LEGEND

SYMBOL

(NUMBER SHOWS OPENING RATING)

BARRIER OPENING RATING

CORRIDOR POSITIVE LATCH DOOR HARDWARE(SMOKE BARRIER)

EXISTING 45 MIN.

EXISTING

ONE HOUR1HR

SM

NOTE: FOR SCHEDULED OPENINGS WHERE SMOKE AND FIRE SEPARATIONS COINCIDE,THE MORE STRINGENT FIRE RATING SHALL APPLY. REFER TO THE PARTITION SCHEDULE FOR FIRE RESISTIVE REFERENCES.

FIRE EXTINGUISHER, PROVIDE 'S12' SIGNAGE AT ALL NEW EXTINGUISHER

LOCATIONS

INDICATES PATH OF TRAVEL TO POINT OF EXIT (FROM COMMON PATH OF TRAVEL)

EXISTING 90 MIN.2HR

EXISTING

TWO HOUR

APPLICABLE CODES:

• NFPA 13-2022 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

• NFPA 14-2019 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOUSE SYSTEMS

• NFPA 24-2022 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR

APPURTENANCES

• NFPA 70-2020 NATIONAL ELECTRICAL CODE

• NFPA 72-2022 NATIONAL FIRE ALARM CODE

• NFPA 90A-2021 STANDARD FOR HEALTH CARE FACILITIES

• NFPA 99-2021 STANDARD FOR HEALTH CARE FACILITIES

• NFPA 101-2021 LIFE SAFETY CODE

• NFPA 220-2021 STANDARD ON TYPES OF BUILDING CONSTRUCTION

• NFPA 291-2022 RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS

• NFPA 1963-2019 STANDARD FOR FIRE HOSE CONNECTIONS

• VA DESIGN GUIDE AND TECHNICAL GUIDE

• VA FIRE PROTECTION DESIGN MANUAL - JUNE 2021

• UNIFORM FEDERAL ACCESSIBILITY STANDARDS WITH VA BARRIER FREE DESIGN GUIDE (PG 18-13)

CHAPTER 6: CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENTS

CHAPTER 39: EXISTING BUSINESS OCCUPANCIES

FIRE SUPPRESSION

FULLY SPRINKLERED

CONSTRUCTION TYPE: TYPE II - 222

NFPA 220 2021 TABLE (4.1.1)

FIRE RESISTANCE RATINGS

ALL WORK PERFORMED COMPLIES WITH EXISTING BUILDING CONSTRUCTION TYPE AND FIRE

RESISTANCE RATINGS

MEANS OF EGRESS CAPACITY

NO CHANGE IN OCCUPANCY.

EXIT ENCLOSURES/PASSAGEWAYS (7.1.3.2.1)

EXISTING TO REMAIN - NO CHANGE IN CAPACITY OR OCCUPANCY

SHAFT ENCLOSURES (8.6.5)

1 HOUR FOR LESS THAN 4 STORIES

2 HOURS FOR 4 STORIES OR MORE

EXIT ACCESS CORRIDORS (38.3.6.1)

NO RATING REQUIRED. LIMIT THE TRANSFER OF SMOKE

STAIRS (7.1.3.2.1A)

2 HOURS FOR 4 STORIES OR MORE

CORRIDOR WIDTH (39.2.3.2)

44" MINIMUM (6'-0" VA STANDARD)

DEAD END CORRIDORS (39.2.5.2)

50' MAXIMUM

HAZARDOUS AREA PROTECTION (39.3.2.1; 8.7.1.1)

HIGH HAZARD AREAS (8.7.1.1)

TRAVEL DISTANCES (39.2.6.3)

300' MAXIMUM

COMMON PATH (39.2.5.2.1)

100' MAXIMUM

BUILDING SIZE

EXISTING TO REMAIN. NO CHANGE IN BUILDING SIZE/ SQUARE

FOOTAGE

BUILDING HEIGHT

EXISTING TO REMAIN. NO CHANGE IN BUILDING HEIGHT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:2

A

M

3-AE102

BUILDING 3 FIRST & SECOND FLOOR LIFE SAFETY

PLANS

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

SITE KEY PLAN

3/32" = 1'-0"2

SECOND FLOOR PLAN - LIFE SAFETY

3/32" = 1'-0"1

FIRST FLOOR PLAN - LIFE SAFETY

N

P N

N

P N

LIFE SAFETY CODE INFORMATION

Revisions: Date:

malbitz Image

C

F

3-AE103

RESTROOM

3-121

F2

D2

D1

M1

G1 F1

P1

A1

P2

D1

TR

3-120

3-120

HW-4A

NEW DATA RACK -

REFER TO

TELECOMMUNICATION

DRAWINGS, TYP

A3

A3

A3

1-AE121

TYP.

CR

S1

4' - 9 5/8"

/2

GENERAL AREA

OF WORK

N

P N

RESTROOM

A

A

(E) AT-1

8'-0"

(E) CLG

@ 8'-0"

(E) CLG

@ 8'-0"

TR

3-120

EQ.EQ.EQ.EQ.

A1

E Q

E Q

DASHED LINES

INDICATE LOCATION

OF DATA RACK

BELOW, TYP

(E) AT-1

8'-0"

OPEN TO

STRUCUTRE

ABOVE

TR

3-120

E/ GC601F1

F2

F3

F

FLOOR= VT-1

WALLS= P-1 OVER 3/4" FIRE

RETARDANT PLYWOOD

BASE= RB-2

PATCH EXISTING

FLOOR AS REQUIRED

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING WALL CONSTRUCTION SHOWN DASHED TO BE

DEMOLISHED AND REMOVED IN ITS ENTIRETY

EXISTING DOOR, HARDWARE AND HM FRAME SHOWN AS

HATCHED TO BE REMOVED IN ITS ENTIRETY

EXISTING WALL MOUNTED WATER CLOSET SHOWN AS DASHED

TO BE REMOVED IN ITS ENTIRETY

EXISTING MILLWORK COUNTER WITH SINK SHOWN AS DASHED

TO BE REMOVED IN ITS ENTIRETY

EXISTING ACOUSTICAL CEILING TILE

SYSTEM TO BE REMOVED

WHERE EXISTING ACOUSTICAL CEILING

TILE SYSTEM TO BE REMOVED.

COORDINATE REMOVAL OF CEILINGS WITH

REPLACEMENT OF EXISTING SPRINKLER

HEADS WITH NEW UPRIGHT SPRINKLER

HEAD TO AVOID LOSS OF FIRE PROTECTION

IN THE CONSTRUCTION AREA.

EXISTING LIGHT FIXTURE TO BE REMOVED

EXISTING MECHANICAL GRILLES TO BE REMOVED.

GC TO MODIFY MECHANICAL SYSTEM AS REQUIRED

SPRINKLER HEAD: MODIFY EXISTING FIRE PROTECTION

SYSTEM AS REQUIRED FOR NEW WORK

EXISTING ANTENNAE TO BE REMOVED

EXISTING HORN / STROBE TO BE REMOVED

C

EXISTING CLOCK TO BE REMOVED AND SALVAGED

NEW LINEAR PENDANT LIGHT FIXTURE, BOT OF

FIXTURE 8'-0" ABOVE FLOOR UNLESS NOTED.

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

NEW CONSTRUCTION

CR INDICATES SCRAMBLE PAD CARD READER LOCATION

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

FLOORING FINISH: VT-1

1. INSTALL MONOLITHICALLY

2. REFER TO FINISH PLAN FOR INSTALL DIRECTION

3. TILES TO BE CENTERED WITHIN ROOM IN

BOTH DIRECTIONS

TR ROOM FINISH NOTE:

IN ALL TR SPACES, PLYWOOD IS ABOVE THE BASE

TO 8'-0" AFF, AND EXCLUDE SHORT RETURN

WALLS. PAINT PLYWOOD AND ALL WALLS P-1.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:4

A

M

3-AE103

BUILDING 3 FIRST FLOOR PLANS - TR 120

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

1/4" = 1'-0"1

FIRST FLOOR PLAN - DEMO

1/4" = 1'-0"2

FIRST FLOOR PLAN - NEW WORK

DEMO RCP KEYNOTES - TR 3-120

MARK DESCRIPTION

A REMOVE EXISTING CEILINGS AND LIGHTING AS SHOWN DASHED IN THEIR ENTIRETY. COORDINATE ALL DEMO WORK WITH OTHER TRADES. SEE MEFP DRAWINGS FOR DEMOLITION OF MECHANICAL, ELECTRICAL, COMMUNICATION AND PIPING

COMPONENTS

1ST FLOOR - MAPLE BUILDING

1/4" = 1'-0"4

FIRST FLOOR RCP - DEMO

1/4" = 1'-0"5

FIRST FLOOR RCP - NEW WORK

1/4" = 1'-0"3

FIRST FLOOR PLAN - FINISHES

DEMOLITION LEGEND - FLOOR PLAN

DEMOLITION LEGEND - RCP

NEW WORK LEGEND - RCP

NEW WORK LEGEND - FLOOR PLAN

DEMO KEYNOTES - TR 3-120

MARK DESCRIPTION

A1 EXISTING CHASE TO REMAIN

D1 EXISTING DOOR, FRAME AND HARDWARE ARE TO BE REMOVED IN THEIR ENTIREY. PREPARE OPENING AS REQUIRED FOR

INFILL.

D2 DOOR IS TO BE REMOVED AND OPENING PREPARED FOR NEW DOOR AND FRAME.

F1 TOILET ROOM: REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED COMPONENTS. REMOVE ALL TOILET ROOM ACCESSORIES. REMOVE PORCELAIN FLOOR TILE SYSTEM. PATCH AND LEVEL FLOOR AS REQUIRED FOR NEW FINISHES

F2 EXISTING CARPET AND FLOOR BASE TO BE REMOVED IN ITS ENTIRETY. PATCH AND PREPARE FLOOR SLAB AS REQUIRED FOR NEW FLOOR FINISH. PATCH ANY AFFECTED EXISTING WALLS TO REMAIN AS REQUIRED - PREPARE FOR NEW SCHEDULED

WALL FINISH.

G1 TOILET ROOM: REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED COMPONENTS. REMOVE ALL TOILET ROOM ACCESSORIES. REMOVE PORCELAIN FLOOR TILE SYSTEM. PATCH AND LEVEL FLOOR AS REQUIRED FOR NEW SCHEDULED

FINISHES.

M1 EXISTING HEATING UNIT TO BE REMOVED IN ITS ENTIRETY - REFER TO MECHANICAL DRAWINGS. PATCH AND REPAIR WALLS

AS REQUIRED FOR NEW SCHEDULED FINISHES.

P1 EXISTING COUNTERTOP SINK AND ALL ASSOCIATED COMPONENTS TO BE REMOVED IN THEIR ENTIRETY. SEE PLUMBING

DRAWINGS FOR MORE INFORMATION.

P2 EXISITING WALL-HUNG TOILET, CHASE AND ASSOCIATED PLUMBING TO BE REMOVED IN THEIR ENTIRETY - REFER TO

PLUMBING DRAWINGS. PATCH REMAINING WALLS AS REQUIRED FOR NEW SCHEDULED FINISHES.

NEW WORK RCP KEYNOTES - TR 3-120

MARK DESCRIPTION

A1 INFILL EXISITNG 2x2 CEILING SYSTEM - GC TO COORDINATE GRID AND CEILING TILE TO MATCH EXISITNG, COR TO APPROVE

FLOOR FINISH LEGEND

FINISHES KEYNOTES - TR 3-120

MARK DESCRIPTION

F1 DOOR FRAME IS TO BE PAINTED IN THE FINSH AND COLOR TO MATCH EXISTING

F2 PATCH/REPAIR WALL WHERE HANDRAIL WAS REMOVED. CORRIDOR FACE OF PARTITION IS TO BE PAINTED TO MATCH EXISTING COLOR AND FINISH AT EXTENT SHOWN. WALL BASE IS TO BE REPLACED WITH NEW LENGTH TO ACCOMODATE DOOR / DOOR

INFILL. COLOR AND PROFILE OF WALL BASE ARE TO MATCH EXISTING (P-1)

F3 PAINT WALL P-1

NEW WORK KEYNOTES - TR 3-120

MARK DESCRIPTION

1 INSTALL FIRE RATED PLYWOOD FROM FINISHED FLOOR UP TO 8'-0" THROUGHOUT

2 EXISTING PARTITION DRYWALL IS TO BE EXTENDED TO THE DECK ABOVE

3 DOOR FINISH TO MATCH STAIN OF EXISTING TO BE REMOVED

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

Revisions: Date:

1 Addendum #1 5/1/2023

D1

A1

F3

P1

F1

A2

D2

124 P2

F2

HAC

3-124

A3

CG-2

S10

3-AE104

A A

(E) CLG

@ 8'-0"

(E) CLG

@ 8'-0"

HAC

3-124

AT-1

8' - 0"

HAC

3-124

CG-2

F1

F2

F3

FD

E/ GC601

FLOOR= PT-1

WALLS= WPT-1

BASE= RB-1

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING WALL CONSTRUCTION SHOWN DASHED TO BE

DEMOLISHED AND REMOVED IN ITS ENTIRETY

EXISTING DOOR, HARDWARE AND HM FRAME SHOWN AS

HATCHED TO BE REMOVED IN ITS ENTIRETY

EXISTING MOP SINK TO REMAIN

EXISTING ACOUSTICAL CEILING TILE

SYSTEM TO BE REMOVED

WHERE EXISTING ACOUSTICAL CEILING

TILE SYSTEM TO BE REMOVED.

COORDINATE REMOVAL OF CEILINGS WITH

REPLACEMENT OF EXISTING SPRINKLER

HEADS WITH NEW UPRIGHT SPRINKLER

HEAD TO AVOID LOSS OF FIRE PROTECTION

IN THE CONSTRUCTION AREA.

EXISTING LIGHT FIXTURE TO BE REMOVED

SPRINKLER HEAD: MODIFY EXISTING FIRE PROTECTION

SYSTEM AS REQUIRED FOR NEW WORK

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

NEW CONSTRUCTION

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

NEW RECESSED 2X2 LIGHT FIXTURE

NEW ACOUSTICAL CEILING TILE SYSTEM

GENERAL AREA

OF WORK

N

P N

FLOORING FINISH: PT-1

1. INSTALL MONOLITHICALLY

2.TILES TO BE CENTERED WITHIN ROOM IN

BOTH DIRECTIONS

3. BASE = RB-1

PT-1 PT-2

EXISTING BASE TO REMAIN.

REPAIR/ REPLACE AS

REQUIRED

PT-2

MOP BASIN

AND FAUCET

PT-2

MOP BASIN

AND FAUCET

PT-2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:5

A

M

3-AE104

BUILDING 3 FIRST FLOOR PLANS - HAC 124

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

1/4" = 1'-0"1

FIRST FLOOR PLAN - DEMO

1/4" = 1'-0"2

FIRST FLOOR PLAN - NEW WORK

1/4" = 1'-0"4

FIRST FLOOR RCP - DEMO

1/4" = 1'-0"5

FIRST FLOOR RCP - NEW WORK

1/4" = 1'-0"3

FIRST FLOOR PLAN - FINISHES

DEMOLITION LEGEND - FLOOR PLAN

DEMOLITION LEGEND - RCP

NEW WORK LEGEND - FLOOR PLAN

NEW WORK LEGEND - RCP

1ST FLOOR - MAPLE BUILDING

DEMO KEYNOTES - HAC 3-124

MARK DESCRIPTION

A1 REMOVE PORTION OF EXISTING PLASTER/LATH WALL AS SHOWN DASHED IN ITS ENTIRETY - REMOVE WALL-MOUNTED MOP RACK AND SALVAGE FOR RELOCATION. FINISH END W/ FLUSH WALL END (NOT SURFACE

APPLIED). WALL SHELF AND SOAP DISPENSER ARE EXISTING TO REMAIN.

A2 EXISTING SHELF W/ SOAP DISPENSER BELOW TO REMAIN - GC TO PROTECT DURING CONSTRUCTION

D1 EXISTING DOOR, FRAME AND HARDWARE ARE TO BE REMOVED IN THEIR ENTIREY. OPENING IS TO BE PREPPED

FOR INFILL

D2 EXISTING DOOR, FRAME AND HARDWARE ARE TO REMAIN AND BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION

F1 EXISTING FLOOR TILE AND WALL TILE ARE TO BE REMOVED IN THEIR ENTIRETY. FLOOR SLAB AND WALL FACE ARE

TO BE PREPPED FOR NEW FINISH. REFER TO FINISH PLANS FOR MORE INFORMATION

F2 EXISTING MARBLE THRESHOLD TO REMAIN - GC TO PROTECT DURING CONSTRUCTION

F3 REMOVE EXISTING FLOORING AND WAL BASE - PREP SLAB AS REQUIRED FOR NEW FLOORING. PATCH AND

PREPARE WALLS AS NECESSARY FOR SCHEDULED FINISHES.

P1 EXISTING MOP SINK AND FAUCET ARE TO REMAIN AND BE PROTECTED DURING DEMOLITION AND CONSTRUCTION

P2 GC PROTECT EXISTING FLOOR DRAIN DURING CONSTRUCTION

DEMO RCP KEYNOTES - HAC 1-124

MARK DESCRIPTION

A REMOVE EXISTING CEILINGS AND LIGHTING AS SHOWN DASHED IN THEIR ENTIRETY. COORDINATE ALL DEMO WORK WITH OTHER TRADES. SEE MEFP DRAWINGS FOR DEMOLITION OF MECHANICAL, ELECTRICAL, COMMUNICATION AND

PIPING COMPONENTS

LEGEND - FLOORING FINISHES

FINISHES KEYNOTES -HAC 3-124

MARK DESCRIPTION

F1 CORRIDOR FACE OF PARTITION IS TO BE PAINTED TO MATCH EXISTING CORRIDOR COLOR AT EXTENT SHOWN

F2 EXISTING DOOR FRAME IS TO BE RE-PAINTED IN COLOR AND FINISH TO MATCH EXISTING

F3 EXISTING MARBLE THRESHOLD IS TO REMAIN

1/2" = 1'-0"6

ELEVATION - HAC 3-124 - NORTH

1/2" = 1'-0"7

ELEVATION - HAC 3-124 - EAST

1/2" = 1'-0"8

ELEVATION - HAC 3-124 - SOUTH

1/2" = 1'-0"9

ELEVATION - HAC 3-124 - WEST

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

Revisions: Date:

F1

M1

D1

A1

TR

3-218

3-218

HW-4A

NEW DATA RACK -

REFER TO

TELECOMMUNICATION

DRAWINGS, TYP

1-AE121

TYP.

CR

S1

4' - 9 3/8"

GENERAL AREA

OF WORK

N

P N

A

(E) CLG

@ 8'-0"

OPEN TO (E)

STRUCTURE ABOVE

(VIF BOS HEIGHT)

TR

3-218

EQ.EQ.EQ.EQ.

E Q

E Q

(E) CLG

@ 8'-0"

DASHED LINE INDICATES DATA RACK

PLACEMENT BELOW - CONFIRM DATA

RACK SIZE, QUANTITY AND

PLACEMENT W/ TELECOMMUNICATION

DRAWINGS

OPEN TO

STRUCTURE

ABOVE

TR

3-218

E/ GC601

F1

F2

FLOOR= VT-1

WALLS= P-1 OVER 3/4" FIRE

RETARDANT PLYWOOD

BASE= RB-2

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING WALL CONSTRUCTION SHOWN DASHED TO BE

DEMOLISHED AND REMOVED IN ITS ENTIRETY

EXISTING DOOR, HARDWARE AND HM FRAME SHOWN AS

HATCHED TO BE REMOVED IN ITS ENTIRETY

EXISTING ACOUSTICAL CEILING TILE

SYSTEM TO BE REMOVED

WHERE EXISTING ACOUSTICAL CEILING

TILE SYSTEM TO BE REMOVED.

COORDINATE REMOVAL OF CEILINGS WITH

REPLACEMENT OF EXISTING SPRINKLER

HEADS WITH NEW UPRIGHT SPRINKLER

HEAD TO AVOID LOSS OF FIRE PROTECTION

IN THE CONSTRUCTION AREA.

EXISTING LIGHT FIXTURE TO BE REMOVED

SPRINKLER HEAD: MODIFY EXISTING FIRE PROTECTION

SYSTEM AS REQUIRED FOR NEW WORK

NEW LINEAR PENDANT LIGHT FIXTURE, BOT OF

FIXTURE 8'-0" ABOVE FLOOR UNLESS NOTED.

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

NEW CONSTRUCTION

1CR INDICATES SCRAMBLE PAD CARD READER LOCATION

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

FLOORING FINISH: VT-1

1. INSTALL MONOLITHICALLY

2. REFER TO FINISH PLAN FOR INSTALL DIRECTION

3. TILES TO BE CENTERED WITHIN ROOM IN

BOTH DIRECTIONS

TR ROOM FINISH NOTE:

IN ALL TR SPACES, PLYWOOD IS ABOVE THE BASE

TO 8'-0" AFF, AND EXCLUDE SHORT RETURN

WALLS. PAINT PLYWOOD AND ALL WALLS P-1.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:1

A

M

3-AE105

BUILDING 3 SECOND FLOOR PLANS - TR 218

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

1/4" = 1'-0"1

SECOND FLOOR PLAN - DEMO

1/4" = 1'-0"2

SECOND FLOOR PLAN - NEW WORK

2ND FLOOR - MAPLE BUILDING

1/4" = 1'-0"4

SECOND FLOOR RCP - DEMO

1/4" = 1'-0"5

SECOND FLOOR RCP - NEW WORK

1/4" = 1'-0"3

SECOND FLOOR PLAN - FINISHES

DEMOLITION LEGEND - FLOOR PLAN

DEMOLITION LEGEND - RCP

NEW WORK LEGEND - RCP

NEW WORK LEGEND - FLOOR PLAN

DEMO RCP KEYNOTES - TR 3-218

MARK DESCRIPTION

A REMOVE EXISTING CEILINGS AND LIGHTING AS SHOWN DASHED IN THEIR ENTIRETY. COORDINATE ALL DEMO WORK WITH OTHER TRADES. SEE MEFP DRAWINGS FOR DEMOLITION OF MECHANICAL, ELECTRICAL, COMMUNICATION AND PIPING

COMPONENTS

DEMO KEYNOTES - TR 3-218

MARK DESCRIPTION

A1 EXISTING WINDOW, FRAME, HEAD, JAMB, AND SILL ARE TO BE REMOVED IN THEIR ENTIRETY. OPENING IS TO BE PREPPED

FOR INFILL

D1 EXISTING DOOR AND FRAME ARE TO BE REMOVED IN THEIR ENTIRETY. OPENING IS TO BE PREPPED FOR NEW DOOR AND

FRAME

F1 REMOVE EXISTING FLOORING AND WALL BASE - PREP SLAB AS REQUIRED FOR NEW FLOORING. PATCH AND PREPARE

WALLS AS NECESSARY FOR SCHEDULED FINISHES.

M1 REMOVE EXISTING HVAC UNIT - REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION

FLOOR FINISH LEGEND

FINISHES KEYNOTES -TR-3-218

MARK DESCRIPTION

F1 DOOR FRAME IS TO BE PAINTED COLOR AND FINISH TO MATCH EXISTING DOORS ADJACENT

F2 CORRIDOR FACE OF PARTITION IS TO BE PAINTED TO MATCH EXISTING COLOR AND FINISH AT EXTENT SHOWN. WALL BASE IS TO BE REPLACED WITH NEW LENGTH AS REQUIRED. COLOR AND PROFILE OF WALL BASE ARE TO MATCH EXISTING

NEW WORK KEYNOTES - TR 3-218

MARK DESCRIPTION

1 INSTALL FIRE RATED PLYWOOD FROM FINISHED FLOOR UP TO 8'-0" THROUGHOUT

2 EXISTING PARTITION TO REMAIN IS TO BE EXTENDED TO THE DECK ABOVE AS REQUIRED

3 EXISTING WINDOW OPENING IS TO BE INFILLED WITH CONSTRUCTION TO MATCH EXISTING EXTERIOR PARTITION SYSTEM.

REFER TO DETAIL FOR MORE INFORMATION

4 DOOR FINISH TO MATCH STAIN OF EXISTING TO BE REMOVED

HAZARDOUS MATERIAL REMOVAL

SCHEDULE 3-218

DESCRIPTION CATEGORY QUANTITY

WINDOW CAULKING / GLAZING COMPOUND (1) WINDOW

HAZARDOUS MATERIAL REMOVAL

KEYNOTES 3-128

MARK DESCRIPTION

1 ASBESTOS CONTAINING WINDOW CAULKING / GLAZING COMPOUND TO BE REMOVED IN ACCORDANCE WITH THE SPECIFICIATIONS. ESTABLISH FULL CONTAINMENT WITH NEGATIVE PRESSURE EXHAUST TO REMOVE ASBESTOS FLOORING AND MASTIC IN ACCORDANCE WITH THE SPECIFICATIONS, ALL APPLICABLE FEDERAL, STATE, AND LOCAL

REGULATIONS, AND THE APPROVED HAZARD ABATEMENT PLAN

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

Revisions: Date:

UP

UP

126 100D

CORRIDOR.

100B

CORRIDOR.

EAST

ELEVATOR

122 121

100C

CORRIDOR.

STORAGE

STAFF

WASHROOM

STAFF

ROOM

CLINIC

CHIEF'S

OFFICE

FEMALE

WASHROOM

MALE

WASHROOM

COUNSELING

OFFICE

#6

COUNSELING

OFFICE

#5

COUNSELING

OFFICE

#4

COUNSELING

OFFICE

#7

COUNSELING

OFFICE

#8

COUNSELING

OFFICE

#9

GROUP

ROOM

#3

COMM.

CENTER

COUNSELING

OFFICE

#3

COUNSELING

OFFICE

#2

COUNSELING

OFFICE

#1

JAN.

CLOSET

WAITING

ROOM

ADRIATIC

WASHROOM

GROUP

ROOM

#2

E C

O R

R

ID

O R

GROUP

ROOM

#1

SMALL

CONFERENCE.

ROOM

TEAM

ROOM

STAIR

A C

O R

R

ID

O R

WEST

ELEVATOR

ELEVATOR

VESTIBULE

ELEV.

MACH.

ROOM

V E

S T

IB

U

LE137

CHANGING

RM.

SOILED

UTILITY 102

STAFF

SWING

OFFICE

101A

PUBLIC

TLT

STAFF

OFFICE

CLEAN

SUPPLY

SPD

LAUNDRY

STAFF

TLT/SHOWER

S102

S101

STAFF TLT

STAFF

LOUNGE

LOCKERS

S114A

MALE

SHOWER

SALLY - PORT

S114

MALE

BATHROOM S137

OPEN GROUP

AREA

S115

MALE

PRIVATE

ROOM

S116

MALE

PRIVATE

ROOM

S105

PHYSICIAN OFFICE

S106

CONFERENCE

ROOM

S104

PSYCHOLOGIST

OFFICE S109

ASLE

S103

NURSE

MANAGER

S110A

NURSE WORK

AREA

S107

STAFF

OFFICE

S108

STAFF

OFFICE

S132A

S132

GROUP/

SENSORY

ROOM

S133

MED ROOM

S110 ASLE

S113

INTERVIEW

S137

DAYROOM/DINING

S

S112

EXAM

ROOM

S111

WARD

CLERK

S134

NURSE

STATION

S137

FEMALE ZONE

S117

MALE

SEMI-PRIVATE

ROOM

S118

MALE

PRIVATE

ROOM

S119

MALE

SEMI-PRIVATE

ROOM

S120A

TOILET

S120

FEMALE

PRIVATE

(ADRIATIC)

S121

FEMALE

PRIVATE

ROOM

S122

FEMALE

SEMI-PRIVATE

ROOM

S123

FEMALE

S. PRV

RESTROOM

S124

FEMALE

LOUNGE

S125

INTERVIEW

ROOM

S126

MALE

SEMI-PRIVATE

ROOM

S131

QUIET

ROOM

S130

MALE

PRIVATE

(ADRIATIC)

S129

PRIVATE

TOILET

S128

MALE

SEMI-

PRIVATE

ROOM

S127

MALE

SEMI-PRIVATE

ROOM

TR

4-105

4-AE103

EXISTING TR

BUILDING 4

N O

R

TH

AM

PTO

N

T11

13S

9A

N

CRAWL SPACE

CRAWL SPACE

CRAWL SPACE

CRAWL SPACE CRAWL SPACE

CRAWL SPACE

STEAM ENTERS BUILDING

CRAWL SPACE

CRAWL SPACE

CRAWL SPACE

SHAFT

OPENING IN

FLOOR ABOVE

CRAWL SPACE

SHAFT

OPENING

IN FLOOR

ABOVE

30"x30'

ACCESS OPENING

30" x 30" ACCESS

OPENING

CRAWL SPACE

MECHANICAL

ROOM

CRAWL SPACE

SHAFT OPENING IN

FLOOR ABOVE

SHAFT OPENING IN

FLOOR ABOVE

30" x 30"

ACCESS OPENING

30" x 30" ACCESS

DOOR

CRAWL SPACECRAWL SPACE

VENT FOR HVAC

DOOR HERE AT THE TOP OF

THESE STAIRS ONTO THE FIRST

FLOOR (SEE FIRST FLOOR

DRAWING

207A

206A

203 202A

223 210HK

201201A

PC1

211 209

200A

P C

P

C

P C

228A

228B

5A 21

4A

227A

234A

230A

PC5

P C

P C

1A

ME HK

EL

240A

246A

DOCTOR

OFFICE 244

SOCIAL

WORK

OFFICE 243

242A

TR

4-233

CONFERENCE

ROOM

CLOSET

4-224

4-AE104

4-AE105

PATIENT LAUNDRY

4-212

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:3

A

M

4-AE101

BUILDING 4 (HORIZON) BASEMENT, FIRST FLOOR &

SECOND FLOOR COMPOSITE PLANS - AREA OF WORK

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

1/16" = 1'-0"2

FIRST FLOOR PLAN

N

P N

N

P N

SITE KEY PLAN

1/16" = 1'-0"1

BASEMENT PLAN

N

P N

1/16" = 1'-0"3

SECOND FLOOR PLAN

Revisions: Date:

126 100D

COOR.

100B

COOR.

EAST

ELEVATOR

122 121

100C

COOR.

STORAGE

STAFF

WASHROOM

STAFF

ROOM

CLINIC

CHIEF'S

OFFICE

FEMALE

WASHROOM

MALE

WASH

ROOM

COUNSELING

OFFICE

#6

COUNSELING

OFFICE

#5

COUNSELING

OFFICE

#4

COUNSELING

OFFICE

#7

COUNSELING

OFFICE

#8

COUNSELING

OFFICE

#9

GROUP

ROOM

#3

COMM.

CENTER

COUNSELING

OFFICE

#3

COUNSELING

OFFICE

#2

COUNSELING

OFFICE

#1

JAN.

CLOSET

WAITING

ROOM

BARIATRIC

WASHROOM

GROUP

ROOM

#2 100E

COOR.

GROUP

ROOM

#1

SMALL

CONF. ROOM

TEAM

ROOM 136

STAIR

100A

CORR.

WEST

ELEVATOR

ELEVATOR

VESTIBULE

ELEV.

MACH.

ROOM

V E

S T

IB

U

LE

CHANGING

RM.

SOILED

UTILTY 102

STAFF

SWING

OFFICE

101A

PUBLIC

TLT

STAFF

OFFICE

CLEAN

SUPPLY

SPD 108

LAUNDRY

STAFF

TLT/SHOWER

S102

STAFF

LOUNGE

LOCKERS

S114A

MALE

SHOWER

SALLY - PORT

S114

MALE

BATHROOM

S137

OPEN GROUP

AREA

S115

MALE

PRIVATE

ROOM

S116

MALE

PRIVATE

ROOM

S105

PHYISICIAN OFFICE S106

CONFERENCE

ROOMS104

PSYCHOLOGIST

OFFICE

S109

ASLE

S103

NURSE

MANAGER

S110A

NURSE WORK

AREA

S107

STAFF

OFFICE

S108

STAFF

OFFICE

S132A

S132

GROUP/

SENSORY

ROOM

S133

MED ROOM

S110 ASLE

S113

INTERVIEW

S137

DAYROOM/DINING

S

S112

EXAM

ROOM

S111

WARD

CLERK

S134

NURSE

STATION

S137

FEMALE ZONE

S117

MALE

SEMI-PRIVATE

ROOM

S118

MALE

PRIVATE

ROOM

S119

MALE

SEMI-PRIVATE

ROOM

S120A

TOILET

S120

FEMALE

PRIVATE

(BARIATRIC)

S121

FEMALE

PRIVATE

ROOM

S122

FEMALE

SEMI-PRIVATE

ROOM

S123

FEMALE

S. PRV

BTHRM

S124

FEMALE

LOUNGE

S125

INTERVIEW

ROOM

S126

MALE

SEMI-PRIVATE

ROOM

S131

QUIET

ROOM

S130

MALE

PRIVATE

(BARIATRIC)

S129

PRIVATE

TOILET

S128

MALE

SEMI-

PRIVATE

ROOM

S127

MALE

SEMI-PRIVATE

ROOM

171 SF

TR

4-105

PATH OF EGRESS

TRAVEL = 38' - 10"

2HR

2HR

2HR 2HR

2HR

2HR

2HR

1HR

2HR2HR

2HR

2HR

2HR2HR

2HR

2HR

2HR

2HR

1HR

1HR

1HR

2HR

2HR

2HR

2HR

SM

SM

SM

1HR

BUILDING 4

N O

R

TH

AM

PTO

N

T11

13S

9A

N

207A

206A

203 202A

223 210HK

201A

PC1

211 209

200A

P C

P

C

P C

228A

228B

5A 21

4A

227A

234A

230A

PC5

P C

P C

1A

ME HK

EL

240A

246A

DOCTOR

OFFICE

SOCIAL WORK

OFFICE

242A

169 SF

TR

4-233

CONFERENCE

ROOM

CLOSET

4-224

PATH OF EGRESS

TRAVEL = 52' - 1"

PATH OF EGRESS

TRAVEL = 18' - 1"

FCFC

2HR

2HR

2HR 2HR

2HR

2HR

2HR2HR

2HR

2HR

2HR

2HR

2HR2HR

2HR2HR2HR

2HR

2HR

2HR

SM

SM

SM

SM

SM

FIRE RATING LEGEND

SYMBOL

(NUMBER SHOWS OPENING RATING)

BARRIER OPENING RATING

CORRIDOR POSITIVE LATCH DOOR HARDWARE(SMOKE BARRIER)

EXISTING 45 MIN.

EXISTING

ONE HOUR1HR

SM

NOTE: FOR SCHEDULED OPENINGS WHERE SMOKE AND FIRE SEPARATIONS COINCIDE,THE MORE STRINGENT FIRE RATING SHALL APPLY. REFER TO THE PARTITION SCHEDULE FOR FIRE RESISTIVE REFERENCES.

FIRE EXTINGUISHER, PROVIDE 'S12' SIGNAGE AT ALL NEW EXTINGUISHER

LOCATIONS

INDICATES PATH OF TRAVEL TO POINT OF EXIT (FROM COMMON PATH OF TRAVEL)

EXISTING 90 MIN.2HR

EXISTING

TWO HOUR

APPLICABLE CODES:

• NFPA 13-2022 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

• NFPA 14-2019 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOUSE SYSTEMS

• NFPA 24-2022 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR

APPURTENANCES

• NFPA 70-2020 NATIONAL ELECTRICAL CODE

• NFPA 72-2022 NATIONAL FIRE ALARM CODE

• NFPA 90A-2021 STANDARD FOR HEALTH CARE FACILITIES

• NFPA 99-2021 STANDARD FOR HEALTH CARE FACILITIES

• NFPA 101-2021 LIFE SAFETY CODE

• NFPA 220-2021 STANDARD ON TYPES OF BUILDING CONSTRUCTION

• NFPA 291-2022 RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS

• NFPA 1963-2019 STANDARD FOR FIRE HOSE CONNECTIONS

• VA DESIGN GUIDE AND TECHNICAL GUIDE

• VA FIRE PROTECTION DESIGN MANUAL - JUNE 2021

• UNIFORM FEDERAL ACCESSIBILITY STANDARDS WITH VA BARRIER FREE DESIGN GUIDE (PG 18-13)

CHAPTER 6: CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENTS

CHAPTER 39: EXISTING BUSINESS OCCUPANCIES

FIRE SUPPRESSION

FULLY SPRINKLERED

CONSTRUCTION TYPE: TYPE II - 222

NFPA 220 2021 TABLE (4.1.1)

FIRE RESISTANCE RATINGS

ALL WORK PERFORMED COMPLIES WITH EXISTING BUILDING CONSTRUCTION TYPE AND FIRE

RESISTANCE RATINGS

MEANS OF EGRESS CAPACITY

NO CHANGE IN OCCUPANCY.

EXIT ENCLOSURES/PASSAGEWAYS (7.1.3.2.1)

EXISTING TO REMAIN - NO CHANGE IN CAPACITY OR OCCUPANCY

SHAFT ENCLOSURES (8.6.5)

1 HOUR FOR LESS THAN 4 STORIES

2 HOURS FOR 4 STORIES OR MORE

EXIT ACCESS CORRIDORS (38.3.6.1)

NO RATING REQUIRED. LIMIT THE TRANSFER OF SMOKE

STAIRS (7.1.3.2.1A)

2 HOURS FOR 4 STORIES OR MORE

CORRIDOR WIDTH (39.2.3.2)

44" MINIMUM (6'-0" VA STANDARD)

DEAD END CORRIDORS (39.2.5.2)

50' MAXIMUM

HAZARDOUS AREA PROTECTION (39.3.2.1; 8.7.1.1)

HIGH HAZARD AREAS (8.7.1.1)

TRAVEL DISTANCES (39.2.6.3)

300' MAXIMUM

FOOTAGE

BUILDING HEIGHT

EXISTING TO REMAIN. NO CHANGE IN BUILDING HEIGHT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:4

A

M

4-AE102

BUILDING 4 FIRST FLOOR & SECOND FLOOR LIFE

SAFETY PLANS

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

1/16" = 1'-0"1

FIRST FLOOR PLAN -LIFE SAFETY N

P N

SITE KEY PLAN

N

P N

1/16" = 1'-0"2

SECOND FLOOR PLAN - LIFE SAFETY

LIFE SAFETY CODE INFORMATION

Revisions: Date:

GENERAL AREA OF WORK

N

P N

1' - 9 5/8"

M1

C1C2

104 105

E1

F1

F2

D1 D1

F1

A1

4-105

HW-4A

TR

4-105

A3 A3

NEW DATA RACKS -

REFER TO

TELECOMMUNICATION

DRAWINGS, TYP

1-AE121

TYP.

CR

S1

/8

5' - 1 7/8"

EXISTING ACOUSTICAL CEILING TILE

SYSTEM TO BE REMOVED

WHERE EXISTING ACOUSTICAL CEILING

TILE SYSTEM TO BE REMOVED.

COORDINATE REMOVAL OF CEILINGS WITH

REPLACEMENT OF EXISTING SPRINKLER

HEADS WITH NEW UPRIGHT SPRINKLER

HEAD TO AVOID LOSS OF FIRE PROTECTION

IN THE CONSTRUCTION AREA.

EXISTING LIGHT FIXTURE TO BE REMOVED

EXISTING MECHANICAL GRILLES TO BE REMOVED.

GC TO MODIFY MECHANICAL SYSTEM AS REQUIRED

SPRINKLER HEAD: MODIFY EXISTING FIRE PROTECTION

SYSTEM AS REQUIRED FOR NEW WORK

EXISTING SMOKE DETECTOR TO BE REMOVED

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING WALL CONSTRUCTION SHOWN DASHED TO BE

DEMOLISHED AND REMOVED IN ITS ENTIRETY

EXISTING DOOR, HARDWARE AND HM FRAME SHOWN AS

HATCHED TO BE REMOVED IN ITS ENTIRETY

AA

104 105

(E) CLG

@ 8'-0"

(E) CLG

@ 8'-0"

(E) CLG

@ 8'-7"

TR

4-105

DASHED LINES INDICATE

LOCATION OF DATA RACK

BELOW, TYP

(E) CLG

@ 8'-0"

OPEN TO STRUCTURE

ABOVE

CABLE TRAY ABOVE

(TYP), SEE

TECHNOLOGY DWGS.

TR

4-105

F2

E/ GC601

F1

FLOOR= VT-1

WALLS= P-1 OVER 3/4" FIRE

RETARDANT PLYWOOD

BASE= RB-2

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

NEW CONSTRUCTION

CR INDICATES SCRAMBLE PAD CARD READER LOCATION

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

NEW LINEAR PENDANT LIGHT FIXTURE, BOT OF

FIXTURE 8'-0" ABOVE FLOOR UNLESS NOTED.

FLOORING FINISH: VT-1

1. INSTALL MONOLITHICALLY

2. TILES TO BE CENTERED WITHIN ROOM IN

BOTH DIRECTIONS

TR ROOM FINISH NOTE:

IN ALL TR SPACES, PLYWOOD IS ABOVE THE BASE

TO 8'-0" AFF, AND EXCLUDE SHORT RETURN

WALLS. PAINT PLYWOOD AND ALL WALLS P-1.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:5

A

M

4-AE103

BUILDING 4 FIRST FLOOR PLANS - TR 105

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

1ST FLOOR - HORIZON BUILDING

1/4" = 1'-0"1

FIRST FLOOR PLAN - DEMO

1/4" = 1'-0"2

FIRST FLOOR PLAN - NEW WORK

DEMOLITION LEGEND - RCP

DEMOLITION LEGEND - FLOOR PLAN

1/4" = 1'-0"4

FIRST FLOOR RCP - DEMO

1/4" = 1'-0"5

FIRST FLOOR RCP - NEW WORK

1/4" = 1'-0"3

FIRST FLOOR PLAN - FINISHES

NEW WORK LEGEND - FLOOR PLAN

NEW WORK LEGEND - RCP

DEMO RCP KEYNOTES - 4-105

MARK DESCRIPTION

A REMOVE EXISTING CEILING(S) & LIGHTING AS SHOWN DASHED IN THEIR ENTIRETY. COORDINATE ALL DEMO WORK WITH OTHER TRADES. SEE MEFP DRAWINGS FOR DEMOLITION OF MECHANICAL, ELECTRICAL, COMMUNICATION AND PIPING

COMPONENTS

DEMO KEYNOTES - 4-105

MARK DESCRIPTION

A1 EXISTING WINDOW, FRAME, HEAD, JAMB, AND SILL ARE TO BE REMOVED IN THEIR ENTIRETY. OPENING IS TO BE PREPPED

FOR INFILL

C1 REMOVE EXISITNG DATA RACK AND ALL ASSOCIATED COMPONENTS AND WIRING AS REQUIRED - REFER TO RELATED TRADE

DRAWINGS. PATCH AND REPAIR SLAB AS REQUIRED FOR NEW SCHEDULED FLOORING

C2 EXISTING COMMUNICATION / IT EQUIPMENT AND ALL RELATED COMPONENTS ARE TO BE REMOVED IN THEIR ENTIRETY – REMOVE EXISTING PLYWOOD FROM WALLS. REFER TO RELATED TRADE DRAWINGS FOR MORE INFORMATION

D1 EXISTING DOOR, FRAME AND HARDWARE ARE TO BE REMOVED IN THEIR ENTIRETY. OPENING IS TO BE PREPPED FOR INFILL

E1 REMOVE EXISTING SURFACE MOUNTED PLUG MOLDING STRIPS THROUGHOUT. COORDINATE WITH ELECTRICAL DRAWINGS

F1 DEMOLISH ALL EXISTING FLOORING, WALL BASE AND WALL FINISHES IN THEIR ENTIRETY. PREP WALLS AND FLOOR SLAB FOR

NEW FINISH

F2 REMOVE EXISTING WINDOW SHADE SYSTEM AND COORDINATING FABRIC IN THEIR ENTIRETY

M1 REMOVE EXISITNG SPLIT-UNIT IN ITS ENTIRETY - PATCH AND REPAIR WALLS AS REQUIRED FOR NEW SCHEDULED FINISHES

FLOOR FINISH LEGEND

FINISHES KEYNOTES - TR 4-105

MARK DESCRIPTION

F1 DOOR FRAME IS TO BE BE PAINTED IN THE FINSH AND COLOR TO MATCH EXISTING

F2 CORRIDOR FACE OF PARTITION IS TO BE PAINTED TO MATCH EXISTING COLOR AND FINISH AT EXTENT SHOWN. WALL BASE IS TO BE REPLACED WITH NEW LENGTH TO ACCOMODATE DOOR / DOOR INFILL. COLOR AND PROFILE OF WALL BASE ARE TO

MATCH EXISTING

NEW WORK KEYNOTES - TR 4-105

MARK DESCRIPTION

1 EXISTING WINDOW OPENING IS TO BE INFILLED WITH CONSTRUCTION TO MATCH EXISTING EXTERIOR PARTITION SYSTEM.

REFER TO DETAIL FOR MORE INFORMATION

2 INSTALL FIRE RATED PLYWOOD FROM FINISHED FLOOR UP TO 8'-0" THROUGHOUT

3 EXISTING PARTITION TO REMAIN IS TO BE EXTENDED TO THE DECK ABOVE AS REQUIRED

4 DOOR FINISH TO MATCH STAIN OF EXISTING TO BE REMOVED

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

Revisions: Date:

GENERAL AREA

OF WORK

N

P N

TR

4-233

4-233

HW-4A

A2

R1

A1

12' - 11 5/8"

ALIGN

ALIGN

ALIGN

2 1/2" 2 1/2"

1-AE121

TYP.

CR

4 6

A4

NEW DATA RACKS - REFER

TO TELECOMMUNICATION

DRAWINGS

S1

5' - 3"

/4

PATIENT

LAUNDRY

A B

C

C

(E) CLG

@ 8'-6"

(E) CLG @ 8'-6"

(E) CLG

@ 8'-6"

(E) CLG

@ 8'-6"

TR

4-233

DASHED LINES INDICATE

LOCATION OF DATA RACK

BELOW, TYP

A

B

AT-2

8' - 6"

(E) CLG

@ 8'-6"

OPEN TO

STRUCTURE ABOVE

CABLE TRAY ABOVE

SEE TECHNOLOGY

DWGS.3

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING WALL CONSTRUCTION SHOWN DASHED TO BE

DEMOLISHED AND REMOVED IN ITS ENTIRETY

EXISTING DOOR, HARDWARE AND HM FRAME SHOWN AS

HATCHED TO BE REMOVED IN ITS ENTIRETY

EXISTING ACOUSTICAL CEILING TILE

SYSTEM TO BE REMOVED

WHERE EXISTING ACOUSTICAL CEILING

TILE SYSTEM TO BE REMOVED.

COORDINATE REMOVAL OF CEILINGS WITH

REPLACEMENT OF EXISTING SPRINKLER

HEADS WITH NEW UPRIGHT SPRINKLER

HEAD TO AVOID LOSS OF FIRE PROTECTION

IN THE CONSTRUCTION AREA.

EXISTING LIGHT FIXTURES TO BE REMOVED

EXISTING MECHANICAL GRILL TO REMAIN

SPRINKLER HEAD: MODIFY EXISTING FIRE PROTECTION

SYSTEM AS REQUIRED FOR NEW WORK

EXISTING WIRELESS ACCESS POINT TO BE

SALVAGED AND PROTECTED IN PLACE

EXISTING GWB SOFFIT TO REMAIN & BE PROTECTED

DURING DEMOLITION & CONSTRUCTION

EXISTING MECHANICAL GRILL TO BE REMOVED

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

CR INDICATES SCRAMBLE PAD CARD READER LOCATION

NEW LINEAR PENDANT LIGHT FIXTURE

NEW 2X2 LIGHT FIXTURE

NEW RECESSED DOWNLIGHT FIXTURE

TR

4-233

E/ GC601

F1

F1

FLOOR= VT-1

WALLS= P-1 OVER 3/4" FIRE

RETARDANT PLYWOOD

BASE= RB-2

FLOORING FINISH: VT-1

1. INSTALL MONOLITHICALLY

2. TILES TO BE CENTERED WITHIN ROOM IN

BOTH DIRECTIONS

GC301

B

F1

A2

A3

A4

A5

P1

PATIENT

LAUNDRY

E1M1

A1

F2

A6

TR ROOM FINISH NOTE:

IN ALL TR SPACES, PLYWOOD IS ABOVE THE BASE

TO 8'-0" AFF, AND EXCLUDE SHORT RETURN

WALLS. PAINT PLYWOOD AND ALL WALLS P-1.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:1

A

M

4-AE104

BUILDING 4 SECOND FLOOR PLANS - TR 233

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

2ND -FLOOR HORIZON BUILDING1/4" = 1'-0"2

SECOND FLOOR PLAN - NEW WORK

1/4" = 1'-0"3

SECOND FLOOR RCP - DEMO

1/4" = 1'-0"4

SECOND FLOOR RCP - NEW WORK

DEMOLITION LEGEND - FLOOR PLAN

DEMOLITION LEGEND - RCP

NEW WORK LEGEND - FLOOR PLAN

NEW WORK LEGEND - RCP

1/4" = 1'-0"5

SECOND FLOOR PLAN - FINISHES

FINISHES KEYNOTES - TR 4-233

MARK DESCRIPTION

F1 WHERE WALL HAS BEEN PATCHED / INFILLED, GC TO FINISH TO MATCH EXISTING CORRIDOR WALL FINISH AND WALL BASE

DEMO KEYNOTES - TR 4-233

MARK DESCRIPTION

A1 EXISTING WALL MOUNTED STORAGE CABINET IS TO BE REMOVED IN ITS ENTIRETY

A2 REMOVE PORTION OF EXISTING FLOORING AND WALL BASE TO ALLOW FOR EXTENT OF NEW WORK PARTITION. PREP SLAB AND

WALLS TO REMAIN FOR NEW FINISH

A3 REMOVE EXISTING COLUMN SURROUND AND ASSOCIATED GWB SOFFIT ABOVE BACK TO EXISTING COLUMN. PREP AREA FOR

NEW FURRING PARTITION AND CEILING

A4 REMOVE PORTION OF EXISTING HANDRAIL / BUMPER RAIL AS REQUIRED TO ALLOW FOR INSTALLATION OF NEW WORK

PARTITION. SALVAGE COMPONENETS AS REQUIRED FOR MODIFICATION

A5 REMOVE EXISTING HANDRAIL / BUMPER RAIL AND PATCH / REPAIR WALL AS REQUIRED FOR NEW FINISH

A6 EXISTING WINDOW, FRAME, HEAD, JAMB, AND SILL ARE TO BE REMOVED IN THEIR ENTIRETY. OPENING IS TO BE PREPPED FOR

INFILL

E1 REMOVE EXISTING DRYER IN ITS ENTIRETY. SALVAGE FOR RE-USE IN NEW PATIENT LAUNDRY ROOM 4-212

F1 DEMOLISH ALL EXISTING FLOORING, WALL BASE AND WALL FINISHES IN THEIR ENTIRETY. PREP WALLS AND FLOOR SLAB FOR

NEW FINISHES

F2 REMOVE EXISTING WINDOW SHADE SYSTEM AND FABRIC IN THEIR ENTIRETY

M1 EXISTING IN-WALL MECHANICAL UNIT IS TO BE REMOVED IN ITS ENTIRETY AND OPENING IS TO BE PREPPED FOR IN-FILL

P1 REMOVE EXISTING WASHING MACHINE AND ASSOCIATED PLUMBING BACK TO SOURCE. SALVAGE FOR USE IN NEW PATIENT

LAUNDRY ROOM 4-212

FLOOR FINISH LEGEND

NEW WORK KEYNOTES - TR 4-233

MARK DESCRIPTION

1 CONTRACTOR TO SUPPLY AND INSTALL NEW HANDRAIL / BUMPER RAIL TO MATCH EXISTING. TO BE INSTALLED AT HEIGHT TO MATCH

EXISTING

2 GC TO CONSTRUCT CHASE TO ENCLOSE COLUMN - UTIILIZE MINIMAL SIZE POSSIBLE TO ENCLOSE COLUMN

3 EXISTING WINDOW OPENING IS TO BE INFILLED WITH CONSTRUCTION TO MATCH EXISTING EXTERIOR PARTITION SYSTEM. REFER TO

DETAIL FOR MORE INFORMATION

4 INSTALL FIRE RATED PLYWOOD FROM FINISHED FLOOR UP TO 8'-0" THROUGHOUT

6 EXISTING PARTITIONS TO REMAIN ARE TO BE EXTENDED TO THE DECK ABOVE AS REQUIRED

7 DOOR FINISH TO MATCH STAIN OF EXISTING TO BE REMOVED

8 INFILL WALL WHERE HVAC UNIT WAS REMOVED. FACE OF INFILL IS TO BE FLUSH WITH FACE OF EXISTING PARTITION ADJACENT, PROVIDE SEAMLESS TRANSITION

DEMO RCP KEYNOTES - TR 4-233

MARK DESCRIPTION

A REMOVE EXISTING CEILING(S) AND LIGHTING AS SHOWN DASHED IN THEIR ENTIRETY. COORDINATE ALL DEMO WORK WITH OTHER TRADES. SEE MEFP DRAWINGS FOR DEMOLITION OF MECHANICAL, ELECTRICAL, COMMUNICATION AND PIPING

COMPONENTS

B EXISTING CEILING IS TO BE BE PARTIALLY DEMOLISHED TO ALLOW FOR INSTALLATION OF NEW WORK PARTITIONS. EXISTING ADJACENT GRID IS TO REMAIN IN TACT AND IS TO BE TIED INTO NEW PARTITION AT PERIMETER

C EXISTING LIGHT FIXTURE IS TO BE REMOVED AND SALVAGED FOR BUILDING STOCK

NEW WORK RCP KEYNOTES - TR 4-233

MARK DESCRIPTION

A EXISTING ACT GRID AND TILE ARE TO BE MODIFIED TO ALLOW FOR NEW WORK PARTITION INSTALLATION. EXISTING GRID IS TO BE

FINISHED AT WALL WITH NEW PERIMETER MOLDING TO MATCH EXISTING ADJACENT GRID

B MODIFY EXISTING ACT GRID / TILE AND GWB SOFFIT AS REQURIED TO ALIGN WITH FACE OF NEW PARTITION

1/4" = 1'-0"1

SECOND FLOOR PLAN - DEMO

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

Revisions: Date:

1 Addendum #1 5/1/2023

E1F1

D1

A CLOSET

4-224

CLOSET

4-224

AT-1

9' - 0"

CLOSET

4-224

4-224

HW-3

S10

CLOSET

4-224

E/ GC601

F2

FLOOR= VT-2

WALLS= P-1

BASE= RB-2

GENERAL AREA OF WORK

N

P N

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING DOOR, HARDWARE AND HM FRAME SHOWN AS

HATCHED TO BE REMOVED IN ITS ENTIRETY

FLOORING FINISH: VT-2

1. INSTALL MONOLITHICALLY

2.TILES TO BE CENTERED WITHIN ROOM

IN BOTH DIRECTIONS

EXISTING LIGHT FIXTURES TO BE REMOVED

EXISTING MECHANICAL GRILL TO BE REMOVED

WHERE EXISTING ACOUSTICAL CEILING TILE SYSTEM TO BE

REMOVED. COORDINATE REMOVAL OF CEILINGS WITH

REPLACEMENT OF EXISTING SPRINKLER HEADS WITH NEW

UPRIGHT SPRINKLER HEAD TO AVOID LOSS OF FIRE

PROTECTION IN THE CONSTRUCTION AREA.

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

NEW CONSTRUCTION

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

NEW ACOUSTICAL CEILING

NEW RECESSED DOWNLIGHT FIXTURE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:3

A

M

4-AE105

BUILDING 4 SECOND FLOOR PLANS - CLOSET 224

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

3/8" = 1'-0"1

SECOND FLOOR PLAN - DEMO

3/8" = 1'-0"4

SECOND FLOOR RCP - DEMO

3/8" = 1'-0"5

SECOND FLOOR RCP - NEW WORK

3/8" = 1'-0"2

SECOND FLOOR PLAN - NEW WORK

3/8" = 1'-0"3

SECOND FLOOR PLAN - FINISHES

2ND -FLOOR HORIZON BUILDING

DEMO RCP KEYNOTES - 4-224

MARK DESCRIPTION

A REMOVE EXISTING CEILING(S) & LIGHTING AS SHOWN DASHED IN THEIR ENTIRETY. COORDINATE ALL DEMO WORK WITH OTHER TRADES. SEE MEFP DRAWINGS FOR DEMOLITION OF MECHANICAL, ELECTRICAL, COMMUNICATION AND PIPING COMPONENTS

NEW WORK KEYNOTES - 4-224

MARK DESCRIPTION

1 PATCH AND REPAIR EXISTING WALLS AND FLOOR AS REQUIRED TO PREP FOR NEW FINISHES

DEMOLITION LEGEND - FLOOR PLAN

FLOOR FINISH LEGEND

DEMOLITION LEGEND - RCP

NEW WORK LEGEND - FLOOR PLAN

NEW WORK LEGEND - RCP

DEMO KEYNOTES - 4-224

MARK DESCRIPTION

D1 EXISTING DOOR HARDWARE IS TO BE REMOVED. EXISTING DOOR AND FRAME ARE TO REMAIN AND BE PROTECTED DURING

DEMOLITION AND CONSTRUCTION. REFER TO DOOR SCHEDULE FOR NEW HARDWARE INFORMATION

E1 EXISTING ELECTRICAL AND COMMUNICATIONS PANELS ARE TO BE REMOVED IN THEIR ENTIRETY AND TAKEN BACK TO SOURCE OR RE-REROUTED AS NECESSARY. REFER TO TELECOM / ELECTRICAL DRAWINGS FOR MORE INFORMATION

F1 DEMOLISH ALL EXISTING FLOORING, WALL BASE AND WALL FINISHES IN THEIR ENTIRETY. PREP WALLS AND FLOOR SLAB FOR

NEW FINISHES

FINISHES KEYNOTES - 4-224

MARK DESCRIPTION

F2 DOOR FRAME IS TO BE BE PAINTED IN THE FINSH AND COLOR TO MATCH EXISTING

NEW WORK RCP KEYNOTES - 4-224

MARK DESCRIPTION

222222

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

Revisions: Date:

1 Addendum #1 5/1/2023

GENERAL AREA

OF WORK

N

P N

P1

P1

F1F2

P2

D1

PATIENT LAUNDRY

4-212

WASHER AND DRYER ARE TO BE

RE-INSTALLED FROM SALVAGED

DEMOLITION. REFER TO PLUMBING

AND ELECTRICAL DRAWINGS FOR

MORE INFORMATION

S1

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED BY THE SPECIFICATIONS WITHIN THE

CONTRACT AREA.

EXISTING WALL CONSTRUCTION SHOWN DASHED TO BE

DEMOLISHED AND REMOVED IN ITS ENTIRETY

A

B

C

D

(E) GWB CLG

TO REMAIN

PATIENT LAUNDRY

4-212

F1

FLOOR= VT-2

WALLS= P-1

BASE= RB-2

CEILING= P-1

FINISHES TO REMAIN.

FINISHES NOTED ARE

FOR ANY TOUCH UP OR

RELATED REPAIR WORK.

EXISTING CONSTRUCTION TO REMAIN. PATCH AS

REQUIRED FOR NEW FINISHES IF INDICATED ON

FINISH SCHEDULE.

S# "S#" INDICATES SIGNAGE LOCATION.

SEE DOOR DETAILS SHEET FOR SIGNAGE TYPES

CR INDICATES SCRAMBLE PAD CARD READER LOCATION

FLOORING FINISH: VT-2

1. INSTALL MONOLITHICALLY

2.TILES TO BE CENTERED WITHIN ROOM

IN BOTH DIRECTIONS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:4

A

M

4-AE106

BUILDING 4 SECOND FLOOR PLANS - PATIENT

LAUNDRY 212

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

2ND -FLOOR HORIZON BUILDING

1/4" = 1'-0"2

SECOND FLOOR PLAN - DEMO

1/4" = 1'-0"3

SECOND FLOOR PLAN - NEW WORK

DEMOLITION LEGEND - FLOOR PLAN

DEMO KEYNOTES - 4-212

MARK DESCRIPTION

D1 EXISTING DOOR, FRAME AND HARDWARE ARE TO REMAIN AND BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION

F1 ALL EXISTING FLOORING, WALL BASE, WALL FINISHES, CEILING FINISH AND LIGHTING ARE TO REMAIN AND BE

PROTECTED DURING DEMOLITION AND CONSTRUCTION, UNLESS NOTED OTHERWISE

F2 EXISTING WALL TILE IS TO BE REMOVED IN ITS ENTIRETY FROM TILE BASE TO CEILING. WALL IS TO BE

PREPPED FOR NEW FINISH. REFER TO FINISH PLAN FOR MORE INFORMATION

P1 EXISTING TUB IS TO BE REMOVED IN ITS ENTIRETY. ALL PLUMBING CONNECTIONS ARE TO BE TAKEN BACK TO

SOURCE OR CAPPED AS REQUIRED. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION

P2 EXISTING WALL MOUNTED LAVATORY IS TO REMAIN AND BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION

1/4" = 1'-0"5

SECOND FLOOR RCP - DEMO

DEMO RCP KEYNOTES - 4-212

MARK DESCRIPTION

A EXISTING GWB CEILING AND LIGHTING ARE TO REMAIN AND BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION

B EXISTING CEILING MOUNTED PATIENT LIFT IS TO BE REMOVED, PATHC/REPAIR CEILING AS REQUIRED

C EXISTING CEILING MOUNTED PRIVACY CURTAIN TRACK IS TO BE REMOVED, PAINT CEILING TO MATCH EXISTING

D EXISTING ACCESS PANEL IS TO REMAIN

1/4" = 1'-0"4

SECOND FLOOR PLAN - FINISHES

FINISHES KEYNOTES - 4-212

MARK DESCRIPTION

F1 WALL IS TO RECEIVE NEW WP-2 UP TO 36" HEIGHT. CAP WALL PROTECTION WITH J-TRIM TO MATCH

NEW WORK LEGEND - FLOOR PLAN

NOTE:

THIS AREA MAY CONTAIN HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO

ASBESTOS AND/OR LEAD. REFER TO HAZARDOUS MATERIALS REPORT AND DIVISION 2

SPECIFICATION SECTIONS 02, 82, 11 (ASBESTOS ABATEMENT) AND 02, 83, 33.13 (LEAD PAINT

REMOVAL AND DISPOSAL), FOR INFORMATION PERTAINING TO THE EXTENT OF MATERIALS

PRESENT, AND THE REQUIRED ABATEMENT PROCESS. IF HAZARDOUS MATERIALS, BEYOND

THE SCOPE OF THE HAZARDOUS MATERIALS REPORT, ARE DISCOVERED STOP ALL WORK

AND NOTIFY THE COR IMMEDIATELY.

FLOOR FINISH LEGEND

Revisions: Date:

DN

U P

D N

D N

UP

U P

Hatchway

BUILDING 5

N O

R

TH

AM

PTO

N

T11

13S

9A

N

TR

5-017A

5-AE103

STORAGE

5-017B

014A

CRAWL SPACE

015HALF DOOR

HALF DOORCRAWL SPACE016

011 ENG

ENG

019020 021022

004 006

HK

003002

EL

ROOM

5-017

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:5

A

M

5-AE101

BUILDING 5 (PINE) BASEMENT COMPOSITE PLANS -

AREA OF WORK

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

SITE KEY PLAN

3/32" = 1'-0"1

BASEMENT PLAN

N

P N

Revisions: Date:

DN

P

D N

D N

UP

U P

Hatchway

BUILDING 5

N O

R

TH

AM

PTO

N

T11

13S

9A

N

148 SF

TR

5-017A

91 SF

STORAGE

5-017B

014A

CRAWL SPACE

015HALF DOOR

HALF DOORCRAWL SPACE016

ENG

ENG

020021022

006HK

EL

029023

FC

P A

T H

O F

E G

R E

S S

T R

A V

E L

2HR

2HR 2HR

2HR

2HR

2HR

FIRE RATING LEGEND

SYMBOL

(NUMBER SHOWS OPENING RATING)

BARRIER OPENING RATING

CORRIDOR POSITIVE LATCH DOOR HARDWARE(SMOKE BARRIER)

EXISTING 45 MIN.

EXISTING

ONE HOUR1HR

SM

NOTE: FOR SCHEDULED OPENINGS WHERE SMOKE AND FIRE SEPARATIONS COINCIDE,THE MORE STRINGENT FIRE RATING SHALL APPLY. REFER TO THE PARTITION SCHEDULE FOR FIRE RESISTIVE REFERENCES.

FIRE EXTINGUISHER, PROVIDE 'S12' SIGNAGE AT ALL NEW EXTINGUISHER

LOCATIONS

INDICATES PATH OF TRAVEL TO POINT OF EXIT (FROM COMMON PATH OF TRAVEL)

EXISTING 90 MIN.2HR

EXISTING

TWO HOUR

APPLICABLE CODES:

• NFPA 13-2022 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

• NFPA 14-2019 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOUSE SYSTEMS

• NFPA 24-2022 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR

APPURTENANCES

• NFPA 70-2020 NATIONAL ELECTRICAL CODE

• NFPA 72-2022 NATIONAL FIRE ALARM CODE

• NFPA 90A-2021 STANDARD FOR HEALTH CARE FACILITIES

• NFPA 99-2021 STANDARD FOR HEALTH CARE FACILITIES

• NFPA 101-2021 LIFE SAFETY CODE

• NFPA 220-2021 STANDARD ON TYPES OF BUILDING CONSTRUCTION

• NFPA 291-2022 RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS

• NFPA 1963-2019 STANDARD FOR FIRE HOSE CONNECTIONS

• VA DESIGN GUIDE AND TECHNICAL GUIDE

• VA FIRE PROTECTION DESIGN MANUAL - JUNE 2021

• UNIFORM FEDERAL ACCESSIBILITY STANDARDS WITH VA BARRIER FREE DESIGN GUIDE (PG 18-13)

CHAPTER 6: CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENTS

CHAPTER 39: EXISTING BUSINESS OCCUPANCIES

FIRE SUPPRESSION

FULLY SPRINKLERED

CONSTRUCTION TYPE: TYPE II - 222

NFPA 220 2021 TABLE (4.1.1)

FIRE RESISTANCE RATINGS

ALL WORK PERFORMED COMPLIES WITH EXISTING BUILDING CONSTRUCTION TYPE AND FIRE

RESISTANCE RATINGS

BUILDING SIZE

EXISTING TO REMAIN. NO CHANGE IN BUILDING SIZE/ SQUARE

FOOTAGE

BUILDING HEIGHT

EXISTING TO REMAIN. NO CHANGE IN BUILDING HEIGHT

MEANS OF EGRESS CAPACITY

NO CHANGE IN OCCUPANCY.

EXIT ENCLOSURES/PASSAGEWAYS (7.1.3.2.1)

EXISTING TO REMAIN - NO CHANGE IN CAPACITY OR OCCUPANCY

SHAFT ENCLOSURES (8.6.5)

1 HOUR FOR LESS THAN 4 STORIES

2 HOURS FOR 4 STORIES OR MORE

EXIT ACCESS CORRIDORS (38.3.6.1)

NO RATING REQUIRED. LIMIT THE TRANSFER OF SMOKE

STAIRS (7.1.3.2.1A)

2 HOURS FOR 4 STORIES OR MORE

CORRIDOR WIDTH (39.2.3.2)

44" MINIMUM (6'-0" VA STANDARD)

DEAD END CORRIDORS (39.2.5.2)

50' MAXIMUM

HAZARDOUS AREA PROTECTION (39.3.2.1; 8.7.1.1)

HIGH HAZARD AREAS (8.7.1.1)

TRAVEL DISTANCES (39.2.6.3)

300' MAXIMUM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ACELAJLH

Office of Construction and

Management

C U s e rs

\J C a g lio n e

\D o c u m e n ts \6

-2

-7

-0

-2

C

G e a ry

A c e la .r v t

/2

/2

:0

:5

A

M

5-AE102

BUILDING 5 BASEMENT LIFE SAFETY PLANS

06/06/2023

Edward P. Boland VA Medical Center

MULTIPLE

621-21-700EHRM INFRASTRUCTURE UPGRADE

CENTRAL WESTERN MASSACHUSETTS

ISSUED FOR BID

FULLY SPRINKLERED

21-USDVA-15

SITE KEY PLAN

3/32" = 1'-0"1

BASEMENT PLAN - LIFE SAFETY N

P N

LIFE SAFETY CODE INFORMATION

Revisions: Date:

GENERAL AREA OF WORK

N

P N

TR

5-017A

STORAGE

5-017B

5-017A

HW-4A

5-017B

HW-3

ROOM

5-017

PANEL

ABOVE

NEW DATA RACK -

REFER TO

TELECOMMUNICATION

DRAWINGS

11' - 0 1/4"A2

A1 A2

A2

A2

A2 A2

4' - 0 3/8" +/-

/8

CR

A1 A1

A2A2

/8

/2

A2

A2

6' - 4 3/4"

17' - 9 1/4"

A2

S1 S1

S1

4' - 6"

F1P1

D1

A2

017A

A1

F1P1A1 E1

E1

ROOM

5-017

TR

5-017A

STORAGE

5-017B

F1

E/ GC601

CG-1CG-1

CG-1 CG-1

F3

F2

F2

F/ GC601

FLOOR= VT-1

WALLS= P-1 OVER 3/4" FIRE

RETARDANT PLYWOOD

BASE= RB-2

FLOOR= VT-2

WALLS= P-1

BASE= RB-1

FLOOR= VT-2

WALLS= P-1

BASE= RB-1

S10

S10

E Q

U A

L EQ

E…