This is Solicitation Addendum #002 for Invitation to Bid S-DASOBO-00016020 issued by the State of Oregon for the MacLaren Youth Correctional Facility Infirmary & Pharmacy Renovation project. The addendum modifies the original bid documents and must be acknowledged and signed by bidders prior to bid closing. The project encompasses renovation and expansion of the infirmary at the Oregon Youth Authority's MacLaren facility, including expansion of the medical lab, security station, medical room and supply areas, receiving/storage area, four patient rooms, a shared day room, nurse station, two supervisor offices, and a meeting room. The addendum extends the bid closing deadline from August 19, 2026 to August 25, 2026 at 2:00 PM Pacific time. Requests for clarification, change requests, and protests regarding the addendum provisions must be submitted to the Department of Administrative Services by 5:00 PM Pacific time on Friday, August 21, 2026. The addendum constitutes a material change to the bid and requires bidder signature and acknowledgment.
The addendum replaces and modifies multiple sections of the technical specifications and drawings, including sections covering general procurement and contracting requirements, glazing systems, impact-rated vision control glass units, and equipment and furniture coordination. New specifications dated August 14, 2026 are provided for glazing (Section 08 80 00), impact-rated vision control interior glass units (Section 08 88 61), and equipment and furniture coordination (Section 11 05 00), along with replacement drawings for sheets A3.11 and Q2.11. The project includes procurement of anti-ligature furniture from Norix, including specialized beds, chairs, tables, and stools designed for correctional facility use, as well as office and meeting room furniture from Office Source. Security glazing specifications include tempered and laminated glass units meeting detention facility standards per ASTM F1915, and vision control glass units certified to AAMA 501.8 for impact resistance rated at 2,000 foot-pound human impact resistance.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INVITATION TO BID
S-DASOBO-00016020
SOLICITATION ADDENDUM #002
MacLaren Youth Correctional Facility Infirmary & Pharmacy Renovation, ADDENDUM #002
This Solicitation Addendum modifies the Bid Document(s) for Work only to the extent indicated herein. All other areas not specifically mentioned or affected by this Solicitation Addendum shall remain in full force. This Solicitation Addendum shall be added as a part of the Original Bidding Document.
This Solicitation Addendum must be acknowledged by providing the required signature prior to Bid Closing. Failure to do so may result in rejection of Bid.
Requests for clarification, requests for change, and protests of Solicitation Addendum provisions addressed in this Solicitation Addendum must be received by DAS by 5:00 P.M. (Pacific time) on Friday, August 21, 2026, or they will not be considered. DAS will not consider requests or protests of matters not added to or modified by this Solicitation Addendum.
New language is indicated by bold print and underline, deleted language is indicated by brackets [ ].
1 Modification ITB, Section A.3 (Page 3) is modified as follows:
Deadline for Bid Submittal (“Closing”) | August [19] 25, 2026 at 2:00 PM
2 Modification ITB Attachment B – Technical Specifications, Section 00 01 10 is deleted in its entirety and replaced with Section 00 01 10 dated August 14, 2026 attached to this Addendum.
3 Modification ITB Attachment B – Technical Specifications, Section 08 80 00 is deleted in its entirety and replaced with Section 08 80 00 dated August 14, 2026 attached to this Addendum.
4 Addition ITB Attachment B – Technical Specifications, Section 08 88 61 dated August 14, 2026 is added.
5 Modification ITB Attachment B – Technical Specifications, Section 11 05 00 is deleted in its entirety and replaced with Section 11 05 00 dated August 14, 2026 attached to this Addendum.
6 Addition ITB Attachment B – Technical Specifications, Appendix A is added.
7 Modification ITB Attachment C – Drawings, Sheet A3.11 is deleted in its entirety and replaced with Drawing Sheet A3.11 dated 08/14/2026 attached to this Addendum.
8 Modification ITB Attachment C – Drawings, Sheet Q2.11 is deleted in its entirety and replaced with Drawing Sheet Q2.11 dated 08/14/2026 attached to this Addendum.
This Solicitation Addendum constitutes a MATERIAL CHANGE to the bid; and it MUST BE SIGNED AND RETURNED PRIOR TO THE BID CLOSING DATE AND TIME. ITS RECEIPT MUST ALSO BE ACKNOWLEDGED BY INSERTING ITS NUMBER ON THE APPROPRIATE BLANK LINES IN SECTION H OF THE BID DOCUMENT.
Signature: ___________________________________________________ Date: ____________________
Bidder Name: __________________________________________________________________________
INVITATION TO BID
S-DASOBO-00016020
SOLICITATION ADDENDUM #002
MacLaren Youth Correctional Facility Infirmary & Pharmacy Renovation, ADDENDUM #002
(Please Print)
Attachments:
• ITB Attachment B – Technical Specifications, Section 00 01 10, dated August 14, 2026
• ITB Attachment B – Technical Specifications, Section 08 80 00, dated August 14, 2026
• ITB Attachment B – Technical Specifications, Section 08 88 61, dated August 14, 2026
• ITB Attachment B – Technical Specifications, Section 11 05 00, dated August 14, 2026
• ITB Attachment C – Drawings, Sheet A3.11 Addendum 2, dated 08/14/2026
• ITB Attachment C – Drawings, Sheet Q2.11 Addendum 2, dated 08/14/2026
TABLE OF CONTENTS 00 01 10
August 14, 2026 OYA-MacLaren Infirmary 1 of 4
PROCUREMENT AND CONTRACTING REQUIREMENTS
1.01 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS
A. 00 01 03 - Project Directory B. 00 01 10 - Table of Contents (08.14.2026) C. 00 31 00 - Available Project Information D. 00 43 25 - Substitution Request Form
SPECIFICATIONS
2.01 DIVISION 01 -- GENERAL REQUIREMENTS
A. 01 10 00 - Summary B. 01 20 00 - Price and Payment Procedures C. 01 25 00 - Substitution Procedures D. 01 30 00 - Administrative Requirements E. 01 32 16 - Construction Progress Schedule F. 01 33 00 - Delegated Design Procedures G. 01 40 00 - Quality Requirements H. 01 40 50 - Coordination I. 01 45 33 - Code-Required Special Inspections J. 01 50 00 - Temporary Facilities and Controls K. 01 60 00 - Product Requirements L. 01 61 16 - Volatile Organic Compound (VOC) Content Restrictions M. 01 70 00 - Execution and Closeout Requirements N. 01 73 29 - Cutting and Patching O. 01 74 19 - Construction Waste Management and Disposal P. 01 78 00 - Closeout Submittals Q. 01 79 00 - Demonstration and Training R. 01 91 13 - General Commissioning Requirements
2.02 DIVISION 02 -- EXISTING CONDITIONS
A. 02 41 00 - Demolition
2.03 DIVISION 03 -- CONCRETE
A. 03 30 00 - Cast-in-Place Concrete
2.04 DIVISION 05 -- METALS
A. 05 12 00 - Structural Steel Framing B. 05 40 00 - Cold-Formed Metal Framing
2.05 DIVISION 06 -- WOOD, PLASTICS, AND COMPOSITES
A. 06 10 00 - Rough Carpentry B. 06 17 33 - Wood I-Joists C. 06 18 00 - Glued-Laminated Construction D. 06 41 00 - Architectural Wood Casework
2.06 DIVISION 07 -- THERMAL AND MOISTURE PROTECTION
A. 07 14 00 - Fluid-Applied Waterproofing
August 14, 2026 OYA-MacLaren Infirmary 2 of 4
B. 07 21 00 - Thermal Insulation C. 07 25 00 - Weather Barriers D. 07 42 13.23- Metal Composite Material Wall Panels E. 07 46 16 - Aluminum Siding F. 07 54 00 - Thermoplastic Membrane Roofing G. 07 62 00 - Sheet Metal Flashing and Trim H. 07 84 00 - Firestopping I. 07 92 00 - Joint Sealants
2.07 DIVISION 08 -- OPENINGS
A. 08 11 13 - Hollow Metal Doors and Frames B. 08 14 16 - Flush Wood Doors C. 08 31 00 - Access Doors and Panels D. 08 43 13 - Aluminum-Framed Storefronts E. 08 51 13 - Aluminum Windows F. 08 62 23 - Tubular Skylights G. 08 63 00 - Metal-Framed Skylights H. 08 71 00 - Door Hardware I. 08 80 00 - Glazing (08.14.2026) J. 08 88 61 - Impact Rated Vision Control Interior (08.14.2026) K. 08 91 00 - Louvers
2.08 DIVISION 09 -- FINISHES
A. 09 00 00 - Interior Finish Products B. 09 00 00.1 - Interior Finish Product Schedule C. 09 05 61 - Common Work Results for Flooring Preparation D. 09 21 16 - Gypsum Board Assemblies E. 09 22 16 - Non-Structural Metal Framing F. 09 24 00 - Cement Plastering G. 09 30 00 - Tiling H. 09 51 00 - Suspended Acoustical Ceilings I. 09 65 00 - Resilient Flooring J. 09 68 13 - Tile Carpeting K. 09 91 13 - Exterior Painting L. 09 91 23 - Interior Painting
2.09 DIVISION 10 -- SPECIALTIES
A. 10 11 00 - Visual Display Units B. 10 26 00 - Wall and Door Protection C. 10 28 00 - Toilet, Bath, and Laundry Accessories D. 10 44 00 - Fire Protection Specialties E. 10 56 17 - Wall Mounted Standards and Shelving
2.10 DIVISION 11 -- EQUIPMENT
August 14, 2026 OYA-MacLaren Infirmary 3 of 4
A. 11 05 00 - Equipment and Furniture Coordination (08.14.2026)
2.11 DIVISION 12 -- FURNISHINGS
A. 12 36 00 - Countertops
2.12 DIVISION 21 -- FIRE SUPPRESSION
A. 21 00 00 - Fire Protection Design-Build Criteria B. 21 05 00 - Common Work Results for Fire Suppression C. 21 05 53 - Identification for Fire Suppression Piping and Equipment D. 21 13 13 - Wet Pipe Sprinkler Systems
2.13 DIVISION 22 -- PLUMBING
A. 22 05 16 - Expansion Fittings and Loops for Plumbing Piping B. 22 05 17 - Sleeves and Sleeve Seals for Plumbing Piping C. 22 05 23 - General-Duty Valves for Plumbing Piping D. 22 05 29 - Hangers and Supports for Plumbing Piping and Equipment E. 22 05 48 - Vibration and Seismic Controls for Plumbing Piping and Equipment F. 22 05 53 - Identification for Plumbing Piping and Equipment G. 22 07 16 - Plumbing Equipment Insulation H. 22 07 19 - Plumbing Piping Insulation I. 22 08 00 - Commissioning of Plumbing J. 22 10 05 - Plumbing Piping K. 22 10 06 - Plumbing Piping Specialties L. 22 30 00 - Plumbing Equipment M. 22 40 00 - Plumbing Fixtures
2.14 DIVISION 23 -- HEATING, VENTILATING, AND AIR-CONDITIONING (HVAC)
A. 23 01 30.51 - HVAC Air-Distribution System Cleaning B. 23 05 13 - Common Motor Requirements for HVAC Equipment C. 23 05 29 - Hangers and Supports for HVAC Piping and Equipment D. 23 05 48 - Vibration and Seismic Controls for HVAC E. 23 05 53 - Identification for HVAC Piping and Equipment F. 23 05 93 - Testing, Adjusting, and Balancing for HVAC G. 23 07 13 - Duct Insulation H. 23 07 19 - HVAC Piping Insulation I. 23 08 00 - Commissioning of HVAC J. 23 09 13 - Instrumentation and Control Devices for HVAC K. 23 09 13 - HVAC Instrumentation and Controls L. 23 11 23 - Facility Natural Gas Piping M. 23 23 00 - Refrigerant Piping N. 23 31 00 - HVAC Ducts and Casings O. 23 33 00 - Air Duct Accessories P. 23 34 23 - HVAC Power Ventilators Q. 23 37 00 - Air Outlets and Inlets R. 23 72 23 - Packaged Air-To-Air Energy Recovery Units
August 14, 2026 OYA-MacLaren Infirmary 4 of 4
S. 23 81 26.13 - Small-Capacity Split-System Air Conditioners T. 23 81 29 - Variable Refrigerant Flow HVAC Systems
2.15 DIVISION 26 -- ELECTRICAL
A. 26 05 05 - Selective Demolition for Electrical B. 26 05 11 - Requirements for Electrical Installations C. 26 05 13 - Medium-Voltage Cables D. 26 05 19 - Low-Voltage Electrical Power Conductors and Cables E. 26 05 26 - Grounding and Bonding for Electrical Systems F. 26 05 29 - Hangers and Supports for Electrical Systems G. 26 05 33.13 - Conduit for Electrical Systems H. 26 05 33.16 - Boxes for Electrical Systems I. 26 05 48 - Vibration and Seismic Controls for Electrical Systems J. 26 05 53 - Identification for Electrical Systems K. 26 05 73 - Power System Studies L. 26 08 00 - Commissioning of Electrical M. 26 09 23 - Lighting Control Devices N. 26 24 16 - Panelboards O. 26 27 13 - Electricity Metering P. 26 27 26 - Wiring Devices Q. 26 28 13 - Fuses R. 26 28 16.16 - Enclosed Switches S. 26 36 00 - Transfer Switches T. 26 51 00 - Interior Lighting U. 26 56 00 - Exterior Lighting
2.16 DIVISION 27 -- COMMUNICATIONS
A. 27 05 28 - Pathways for Communications Systems B. 27 05 29 - Hangers and Supports for Communications Systems C. 27 05 33.13 - Conduit for Communications Systems D. 27 10 00 - Structured Cabling
2.17 DIVISION 28 -- ELECTRONIC SAFETY AND SECURITY
A. 28 13 00 - Access Control System B. 28 20 00 - Video Surveillance C. 28 46 00 - Fire Detection and Alarm
2.18 APPENDIX
A. Appendix A: Furniture (08.14.2026)
END OF SECTION
GLAZING 08 80 00
August 14, 2026 OYA-MacLaren Infirmary 1 of 2
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Insulating glass units.
B. Glazing units.
C. Glazing compounds.
D. Skylight Glazing.
1.02 RELATED REQUIREMENTS
A. Section 08 11 13 - Hollow Metal Doors and Frames: Glazed lites in doors and borrowed lites.
B. Section 08 51 13 - Aluminum Windows: Glazing provided by window manufacturer.
1.03 REFERENCE STANDARDS
A. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials; Current Edition.
B. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.
C. ASTM F1233 - Standard Test Method for Security Glazing Materials And Systems; 2021.
D. ASTM F1915 - Standard Test Methods for Glazing for Detention Facilities; 2005 (Reapproved
2025).
E. GANA (GM) - GANA Glazing Manual; 2022.
F. GANA (SM) - GANA Sealant Manual; 2008.
G. IGMA TM-3000 - North American Glazing Guidelines for Sealed Insulating Glass Units for
Commercial & Residential Use; 1990 (Reaffirmed 2016).
1.04 SUBMITTALS
A. See Section 01 30 00 - Administrative Requirements for submittal procedures.
B. Product Data on Insulating Glass Unit, Glazing Unit, Plastic Sheet Glazing Unit, and Plastic
Film Glazing Types: Provide structural, physical and environmental characteristics, size limitations, special handling and installation requirements.
C. Product Data on Glazing Compounds and Accessories: Provide chemical, functional, and environmental characteristics, limitations, special application requirements, and identify available colors.
1.05 QUALITY ASSURANCE
A. Perform Work in accordance with GANA (GM), GANA (SM), GANA (LGRM), and IGMA TM-
3000 for glazing installation methods. Maintain one copy on site.
1.06 WARRANTY
A. See Section 01 78 00 - Closeout Submittals for additional warranty requirements.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Glass Fabricators:
1. Global Security Glazing.
2.02 BASIS OF DESIGN - INSULATING GLASS UNITS
A. Basis of Design (Exterior)
1. Type G1: 1 7/16” SB70VT #2 on Clear Tempered Insulated Secur-Tem + Poly® 2116 B. Basis of Design (Skylight Glazing):
1. Double Glazed: Laminated, factory sealed.
a. Outer Glazing: Clear Transparent.
b. Inner Glazing: Clear Transparent.
c. Thermal Transmittance (U-Value): 0.50 max, nominal.
GLAZING 08 80 00
August 14, 2026 OYA-MacLaren Infirmary 2 of 2
d. Solar Heat Gain Coefficient (SHGC): 0.40.
2.03 GLAZING UNITS
A. Basis of Design (Interior);
1. Type G2: 11/16” Clear Secur-Tem + Poly® 211
2.04 GLAZING COMPOUNDS
A. Type GC-5 - Silicone Sealant: Single component; neutral curing; capable of water immersion without loss of properties; non-bleeding, non-staining; ASTM C920 Type S, Grade NS, Class 25, Uses M, A, and G; with cured Shore A hardness range of 15 to 25; color as selected.
2.05 ACCESSORIES
A. As indicated for Basis of Design windows
PART 3 EXECUTION
3.01 VERIFICATION OF CONDITIONS
A. Verify that openings for glazing are correctly sized and within tolerances, including those for size, squareness, and offsets at corners.
B. Verify that surfaces of glazing channels or recesses are clean, free of obstructions that may impede moisture movement, weeps are clear, and support framing is ready to receive glazing system.
3.02 PREPARATION
A. Clean contact surfaces with appropriate solvent and wipe dry within maximum of 24 hours before glazing. Remove coatings that are not tightly bonded to substrates.
B. Seal porous glazing channels or recesses with substrate compatible primer or sealer.
C. Prime surfaces scheduled to receive sealant where required for proper sealant adhesion.
3.03 INSTALLATION, GENERAL
A. Install glazing sealants in accordance with ASTM C1193, GANA (SM), and manufacturer's instructions.
3.04 FIELD QUALITY CONTROL
A. Monitor and report installation procedures and unacceptable conditions.
3.05 CLEANING
A. Remove excess glazing materials from finish surfaces immediately after application using solvents or cleaners recommended by manufacturers.
B. Remove nonpermanent labels immediately after glazing installation is complete.
C. Clean glass and adjacent surfaces after sealants are fully cured.
D. Clean glass on both exposed surfaces not more than 4 days prior to Date of Substantial
Completion in accordance with glass manufacturer's written recommendations.
3.06 PROTECTION
A. After installation, mark pane with an 'X' by using removable plastic tape or paste; do not mark heat absorbing or reflective glass units.
B. Remove and replace glass that is damaged during construction period prior to Date of Substantial Completion.
IMPACT RATED VISION CONTROL GLASS UNITS (INTERIOR) 08 88 61
PART 1 GENERAL
PART 1 GENERAL
1.1 ADMINISTRATIVE REQUIREMENTS
A. Pre-Installation Conference:
1. Attendance: Architect,Owner,Contractor,installer, and related trades.
2. Review: Project conditions, manufacturer requirements, delivery and storage, staging and sequencing, and protection of completed work.
1.2 SUBMITTALS
A. Action Submittals:
1. Product Data: Descriptive data and performance attributes for vision control glass.
2. Samples: [8-1/2 x 13-1/2] vision control glass samples.
B. Closeout Submittals:
1. Maintenance Instructions.
1.3 SYSTEM DESCRIPTION
A. Vision Control Glass: Control vision through insulating glass unit assemblies by means of rotating, cordless, interlocking, extruded aluminum louvers with rotation by means of electric motor.
1.4 QUALITY ASSURANCE
A. Impact-Rated Vision Control Glass Units: Certified to AAMA 501.8 for 2000 foot-pound human impact resistance.
B. Regulatory Requirements:
1. Provide impact-resistant glazing for locations subject to human impact as required by Building Code.
2. Safety glass: Tested and labeled to CPSC 16 CFR 1201.
C. Installer Qualifications: Minimum 2 years’ experience in work of this Section.
D. Electrical Components: Listed by UL.
E. Mockup:
1. Provide mockup of vision control glass unit.
2. Locate where directed.
3. Approved mockup may remain as part of the Work.
1.5 WARRANTIES
A. Vision Control Glass Units: Manufacturer’s 20 year warranty against malfunction, mechanism failure and premature wear of internal parts, and material obstruction of glass units by dust or film formation due to failure of hermetic seal.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Contract Documents are based on Vision Control] [Vision Control Mini by Unicel Architectural
Corp., 800-668-1580, www.unicelarchitectural.com.
B. Substitutions: Not permitted.
2.2 MATERIALS
A. Clear Tempered Glass: ASTM C1048, Type 1 transparent flat, Class 1 clear, Quality q3 glazing select, Kind FT fully tempered.
B. Polycarbonate Sheet:
1. Type: ANSI Z97.1; plastic compound, ultraviolet stabilized, non-yellowing, abrasion resistant coated.
2. Color: As selected by Architect.
C. Aluminum Extrusions: ASTM B221.
2.3 MATERIALS – ALUMINUM
A. Aluminum Extrusions: ASTM B221.
2.4 MANUFACTURED UNITS
A. Impact-Rated Vision Control Glass Units
1. Perimeter frame: Extruded aluminum, tubular profile, 1-3/4 x [5] [6] inches, with snap-on glazing stops.
2. Sealed insulating glass units:
a. Impact side: 1/2 inch thick clear polycarbonate sheet.
b. Airspace: [2-1/2] [2] [1-1/4] inches.
willsloman Rectangle willsloman Text Box [1-1/4] inches
IMPACT RATED VISION CONTROL GLASS UNITS (INTERIOR) 08 88 61
c. Non-impact side: 1/4 inch 6 mm thick clear tempered glass.
3. Louvers: Cordless, hollow extruded aluminum, interlocking profile.
4. Operator: motor operator with flexible shaft.
2.5 FABRICATION
A. Sealed Insulating Glass Units: Comply with ASTM E2190.
B. Laminated Glass: Comply with ASTM C1172 and ANSI Z97.1.
2.6 FINISHES
A. Aluminum Framing: AAMA 2603, PPG Duracron acrylic extrusion coating, color to be selected.
B. Louvers: AAMA 2603, PPG Duracron acrylic extrusion coating, custom color to be selected.
PART 3 EXECUTION
3.1 INSTALLATION
A. Install in accordance with vision control glass unit manufacturer's instructions and approved
Shop Drawings.
EQUIPMENT AND FURNITURE COORDINATION 11 05 00
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Coordination and Installation of Owner-Furnished-Contractor-Installed (OFCI) equipment.
B. Procurement and Installation of Contractor-Furnished-Contractor-Installed (CFCI) furniture.
1.02 RELATED REQUIREMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 1 Specification Sections, apply to this Section.
B. See Section 01 30 00-Administrative Requirements for submittal procedures.
1.03 COORDINATION
A. Coordinate construction operations and the work of subcontractors to assure efficient and orderly installation of OFCI equipment. Coordinate construction operations included under different Sections that depend on each other for proper installation, connection, and operation of this equipment.
1. Schedule construction operations in the sequence required to obtain the best results where installation of one part of the Work depends on installation of other components, before or after its own installation.
2. Coordinate installation of different components to assure maximum accessibility for required maintenance, service, and repair.
3. Make provisions to accommodate items scheduled for later installation.
4. Contractor to provide and install all electrical boxes, conduits and backing for OFCI and
OFOI items.
B. Procure and coordinate construction operations and the work of subcontractors to assure efficient and orderly installation of CFCI furnishings. Coordinate construction operations included under different Sections that depend on each other for proper installation, connection, and operation of this equipment.
1.04 SUBMITTALS
A. See Section 01 30 00 - Administrative Requirements for submittal procedures.
B. Product Data: Provide data on specified products, including size, colors available, and installation instructions.
C. Verification Samples: Submit two samples, inch in size illustrating for product specified.
D. Maintenance Data: Include maintenance materials and accesories.
E. Warranty: Manufacturer warranty.
1.05 SCOPE OF WORK
A. The Owner will provide equipment to be incorporated into the work by the contractor as indicated in the drawings. Contractor to provide installation, including structural engineering and seismic bracing, electrical and/or plumbing services as required.
B. The Owner will provide equipment to be incorporated into the work by Owner's vendor as indicated in the drawings. The installation of this equipment will be performed by the Vendor.
Contractor to coordinate schedule and installation requriements (such as backing) with Vendor.
Provide rough-in mechanical and electrical items and blocking for this equipment as indicated on Drawings.
C. The Contractor will aquire and install CFCI furniture as indicated in the drawings and Appendix A.
PART 2 PRODUCTS
2.01 CFCI FURNISHINGS
A. As Appendix A: Furniture.
B. All CFCI items indicated in drawings.
EQUIPMENT AND FURNITURE COORDINATION 11 05 00
C. Substitutions: See Section01 60 00-Product Requirements.
2.02 MATERIALS
A. Fasteners, Screws, and Bolts: Hot dip galvanized; tamper-proof; security type.
2.03 FINISHES
A. Stainless Steel: Satin finish, unless otherwise noted.
PART 3 EXECUTION
3.01 GENERAL
A. Inspection of Conditions: Require the Installer of each major component to inspect both the substrate and conditions under which Work is to be performed. Do not proceed until unsatisfactory conditions have been corrected in an acceptable manner.
B. Coordinate temporary enclosures with required inspections and tests to minimize the necessity of uncovering completed construction for that purpose.
3.02 CLEANING AND PROTECTION
A. Clean and protect construction in progress and adjoining materials in place, during handling and installation. Apply protective covering where required to assure protection from damage or deterioration at Substantial Completion.
B. Clean and provide maintenance on completed construction as frequently as necessary through the remainder of the construction period. Adjust and lubricate operable components to assure operability without damaging effects.
C. Limiting Exposures: Supervise construction operations to assure that no part of the construction, completed or in progress, is subject to harmful, dangerous, damaging, or otherwise deleterious exposure during the construction period.
3.03 INSTALLATION
A. Install accessories in accordance with manufacturers' instructions in locations indicated on drawings.
Appendix A:
Furniture
ANTI-LIGATURE FURNITURE
OFFICE/MEETING ROOM
FURNITURE
August 14, 2026
ANTI-LIGATURE FURNITURE
Bed (BED-PT) - Norix Prodigy Bed model PRD100
Chair (BHC) - Norix Coupe Armless Lounge Chair Model CP11
Table (BHT) - Norix B-Side model BE985
Stool (SF) - Norix S561-100 floor mount stool Slammer Stone Seat
Desk Wall Mounted(D-WM) - Norix model ATN620 Attenda.
One Innovation Drive, West Chicago, IL 60185 | Phone: 630-231-1331 | Toll Free: 800-234-4900 | E-mail: furniture@norix.com Specifications subject to change without notice. | ©2026 Norix Group, Inc. | All Rights Reserved. | Printed in U.S.A. 7/26
Fabrication & Material One-piece, 100% seamless, specially formulated polymer construction is structurally reinforced for superior durability, impact resistance and security.
Rounded edges for added safety, grooved sleep surface for fluid management.
Each piece is uniquely fashioned with proprietary TruGrain™ polymer formulation to replicate natural wood, and deliver a residential, non-institutional appearance.
The seamless, one-piece construction delivers long-term, maintenance-free performance superior to wood in infection-control, fluid, tamper, infestation, contraband resistance and ligature resistant design. Contains a minimum of 45% recycled content. Made in the U.S.A.
Warranty Lifetime warranty.
Maintenance For routine and regular cleaning, Norix® recommends the use of Simple Green® or an equivalent cleaning product with a soft damp cloth. Prodigy® products are suitable for use with hospital-grade disinfectants (such as Virex®, Wexcide® or Oxivir Five 16®) per manufacturers’ instructions.
Norix recommends inspecting fasteners after each use of the restraints, along with regular monthly inspections. Bolt-down fasteners should be tight with no gaps between the bottom of the bed and the floor. There should be no visible cracks in the caulk.
Installation PRD100 - Proprietary ligature resistant floor anchoring system with concealed hardware (mechanism and all anchoring hardware included). Anchoring mechanism and hardware intended for concrete floors and/or walls. (Please consult contractor or facility management as necessary.) Security caulk may be applied to the perimeter after anchoring.
PRD100B - No installation necessary. Tamper-resistant non-removable steel encased floor glides are included and may be field installed.
Performance Test Standards
| • | PRD100 - Tested to 1,500 lbs (680.4 kg) static load |
| • | PRD100B - Tested to 1,500 lbs (680.4 kg) static load |
Environmental Test Standards
• GREENGUARD and GREENGUARD Gold Certified by UL Environment. Product certified for low chemical emissions to UL 2818. UL.COM/GG
Flammability Test Standards
• State of California, Technical Bulletin No. 133, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies
• State of California, Technical Bulletin No. 117, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies
• State of California, Technical Bulletin No. 116, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies
• ASTM E1537 Test Method for Fire testing of Real Scale Upholstered Furniture
Items
• NFPA 261 Cigarette Ignition Resistance of Upholstered Furniture
Model PRD100 (Floor Mount)
PRD100B (Free-Standing)
Weight 130 lbs / 59 kg
Dimensions in cm Overall Length 82” 208.3 Overall Width 38” 96.5 Height 18.5” 47
Bed Deck Length 80” 203.2
Bed Deck Width 36” 91.4 Note: Dimensional tolerances are +1% due to manufacturing process.
Mattress Size 36”x80” (91.4x203.2 cm)
Finishes See Design Guide for finish options.
Options PRD100 (Floor Mount)
• Removable Restraint Ring Kit *Ballasting and Post-production sealed bottom are not available on PRD100.
Options PRD100B (Free-Standing)
• Factory Ballasting of 100 lbs / 45.4 kg *Factory Ballasting must be communicated at time of order, products are not field ballastable.
*Restraint Ring Kit, Bolt-down, Post-production Ballasting are not available on PRD100B. Bed type must be specified at time of order.
Patents Patents Pending
*Intended for indoor use only
RECYCLABLE
PRODUCT
PROPRIETARY
WOOD GRAIN
TECHNOLOGY
MADE IN THE
USA
RECYCLABLE
PRODUCT
Prodigy®
Platform Bed Bed (BED-PT)
One Innovation Drive, West Chicago, IL 60185 | Phone: 630-231-1331 | Toll Free: 800-234-4900 | E-mail: furniture@norix.com Specifications subject to change without notice. | ©2025 Norix Group, Inc. | All Rights Reserved. | Printed in U.S.A. 7/25
Fabrication & Material One-piece, rotationally molded, specially formulated, high-impact polyethylene with ultraviolet light stabilizers (to reduce fading). Chemically resistant to blood, vinegar, urine, feces, salt solution and chlorine solution. Premium TruColor™ polymer is fully compounded for superior color consistency and durability. Enhanced UV resistant formulation suitable for both indoor and outdoor use. Rounded edges for added safety and adjustable removable glides to stabilize for un-even surfaces. Made in the U.S.A.
Warranty 5 year limited replacement warranty.
Maintenance For routine and regular cleaning maintenance, Norix® recommends the use of Simple Green® or an equivalent cleaning product. This product is bleach/water solution cleanable and suitable for use with hospital-grade disinfectants (such as Virex®, Wexcide® or Oxivir Five 16®) per manufacturers’ instructions.
Performance Test Standards
| • | Tested to 750 lbs (340.2 kg) static load. |
| • | Product dynamic drop tested to a relative impact force of two times BIFMA 5.4 |
15.4.2 (250 lbs from 18") (113.4 kg from 45.7 cm)
Environmental Test Standards
• GREENGUARD and GREENGUARD Gold Certified by UL Environment. Product certified for low chemical emissions to UL 2818. UL.COM/GG.
Flammability Test Standards
• State of California, Technical Bulletin No. 133, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies.
• State of California, Technical Bulletin No. 117, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies.
• ASTM E1537 Test method for Fire Testing of Real Scale Upholstered Furniture
Items.
Model CP11
Weight 22 lbs / 10 kg (No Drainage)
27 lbs / 12.2 kg (Drainage)
Dimensions in cm Seat Height 17.2” 43.7 Overall Height 30” 76.2 Depth 27.3” 69.3
Width 21.7” 55.1
Finishes See Design Guide for finish options.
Options
• Bolt-Down Plates
• Drainage
• Factory Ballasting (50 lbs / 22.7 kg) *Ballastable up to 50 lbs (22.7 kg) of dry sand and gravel. On site ballast materials not supplied by Norix.
Assembly None required.
RECYCLABLE
PRODUCT
COLOR
COMPOUNDING
TECHNOLOGY
MADE IN THE
USA
Coupe Armless Lounge Chair
Chair (BHC)
One Innovation Drive, West Chicago, IL 60185 | Phone: 630-231-1331 | Toll Free: 800-234-4900 | E-mail: furniture@norix.com Specifications subject to change without notice. | ©2026 Norix Group, Inc. | All Rights Reserved. | Printed in U.S.A. 7/26
Model Weight Top Size Height lbs kg in cm in cm
BE970 (round) 9 4.1 18" Diameter 45.7 Diameter 18” 45.7
BE985 (square) 12 5.5 18"x18" 45.7x45.7
Fabrication & Material One-piece, rotationally-molded, specially formulated, high-impact polyethylene with ultraviolet light stabilizers (to reduce fading). Premium TruColor™ polymer is fully compounded for superior color consistency and durability. Made in USA.
Warranty Lifetime warranty.
Maintenance For routine and regular cleaning maintenance, Norix recommends the use of Simple Green® or an equivalent cleaning product. This product is bleach/water solution cleanable and suitable for use with hospital-grade disinfectants (such as Virex®, Wexcide® or Oxivir Five 16®) per manufacturers’ instructions.
Performance Test Standards
• Product tested to 500 lbs (226.8 kg) static load.
Environmental Test Standards
• GREENGUARD and GREENGUARD Gold Certified by UL Environment. Product certified for low chemical emissions to UL 2818. UL.COM/GG.
Flammability Test Standards
• State of California, Technical Bulletin No. 133, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies
| • | UL1056 Fire Test of Upholstered Furniture |
| • | ASTM E1537 Test Method for Fire Testing of Real Scale Upholstered Furniture |
Items
Finishes See Design Guide for finish options.
Options
• Factory Ballasting (50 lbs / 22.7 kg) *Ballastable up to 100 lbs (45.4 kg) of dry sand.
On site ballast materials not supplied by Norix.
Assembly None required.
*Intended for indoor use only
RECYCLABLE
PRODUCT
COLOR
COMPOUNDING
TECHNOLOGY
MADE IN THE
USA
B-Side Side Table & Stool
Table (BHT)
One Innovation Drive, West Chicago, IL 60185 | Phone: 630-231-1331 | Toll Free: 800-234-4900 | E-mail: furniture@norix.com Specifications subject to change without notice. | ©2024 Norix Group, Inc. | All Rights Reserved. | Printed in U.S.A. 11/24
Fabrication & Material Base: 18” (45.7 cm) high, 2 1/2” (6.4 cm) tubing, fully welded both top and bottom to 6” x 6” x 1/4” (15.2 x 15.2 x 0.6 cm) plates that have four holes each. 11 gauge steel tubing with 1/4” (0.6 cm) thick steel mounting plates.
Seat: 13” (33 cm) diameter Super Slammer Stone. High density, color impregnated compression molded Super Slammer Stone® composite that is highly scratch and stain resistant. Four 5/16” (0.8 cm) diameter molded-in threaded inserts for superior metal-to-metal connection.
Warranty 1 year limited replacement warranty.
Maintenance Legs: Norix recommends the use of soap and water for both the regular cleaning maintenance and deep-scrub cleaning of powder coated steel.
Seat: For routine and regular cleaning maintenance, Norix recommends the use of Simple Green® or an equivalent cleaning product. For the deep-scrub cleaning of tougher stains, marks and debris, we recommend the use of Clorox® Clean-Up® Cleaner + Bleach or an equivalent cleaning solution.
Installation Mounts directly to floor. Floor mounting hardware not included.
Model S561-100
Weight 14 lbs / 6.4 kg
Dimensions in cm Overall Height 18.5” 47 Base Width 6” 15.2 Seat Diameter 13” 33
Finishes See Design Guide for finish options.
Base: Grey Powder Coat
Assembly Attach seat to base.
*Intended for indoor use only
Floor Mount Stool Slammer Stone® Seat
Stool (SF)
One Innovation Drive, West Chicago, IL 60185 | Phone: 630-231-1331 | Toll Free: 800-234-4900 | E-mail: furniture@norix.com Specifications subject to change without notice. | ©2024 Norix Group, Inc. | All Rights Reserved. | Printed in U.S.A. 9/24
Fabrication & Material Base: Slightly textured, maintenance-free surface allows for easy cleaning.
Rotationally molded, specially formulated, high-impact polyethylene with ultraviolet light stabilizers (to reduce fading). Chemically resistant to blood, vinegar, urine, feces, salt solution and chlorine solution. Ligature resistant design with no internal openings. Premium TruColor™ material is fully compounded for superior color consistency and durability. Unit is filled with rigid polyurethane foam for increased durability and sound absorption.
Optional Laminate Top: 45 lb (20.4 kg) density M3 grade particle board with embedded T-nuts for mechanically attaching top to base with a secure steel-to-steel connection. Decorative high-pressure laminate sealed with a specially formulated, highly durable molded edge. Edge is radiused for safety and pressure fused to the top, making it highly sanitary. Made in the U.S.A.
Warranty 10 year limited replacement warranty.
Norix recommends products placed in storage prior to installation should be held in a climate controlled area similar to the room where the product will be used. Norix also recommends that any Attenda® products shipped via ocean container maintain a temperature of 70-75°F (21.1-23.9°C) with a relative humidity of 35%.
Maintenance For routine and regular cleaning maintenance, Norix recommends the use of Simple Green® or an equivalent cleaning product. Attenda® products are bleach/ water solution cleanable and suitable for use with hospital-grade disinfectants (such as Virex®, Wexcide® or Oxivir Five 16®) per manufacturers’ instructions.
Installation Anchors required for permanently attaching to solid wall. Anchors not supplied by Norix. Groove along mounting surface for caulk application (caulk not supplied by Norix).
Patents This product may be covered by US Patent No. US 8,007,059 B2.
Performance Test Standards
• Product tested to 1,000 lbs (453.6 kg) static load.
Environmental Test Standards
• GREENGUARD and GREENGUARD Gold Certified by UL Environment. Product certified for low chemical emissions to UL 2818. UL.COM/GG.
Flammability Test Standards
• State of California, Technical Bulletin No. 133, Flammability Test Procedurefor
Seating Furniture for Use in Public Occupancies
• State of California, Technical Bulletin No. 117, Flammability Test Procedure for
Seating Furniture for Use in Public Occupancies
| • | UL1056 Fire Test of Upholstered Furniture |
| • | ASTM E1537 Test Method for Fire Testing of Real Scale Upholstered Furniture |
Items
• NFPA 261 Cigarette Ignition Resistance of Upholstered Furniture
Model ATN620
Weight 45 lbs / 20.4 kg (No Laminate)
65 lbs / 29.5 kg (Laminate)
Dimensions in cm Width 35.5” 90.2 Depth 23.7” 60.2 Height (No Laminate) 23.8” 60.6
Height (Laminate) 24.8” 62.5 *Note: Dimensional tolerances are +1% due to manufacturing process.
Finishes See Design Guide for finish options.
Options
• ATN620: Without Laminate
• ATN621: Without Laminate and without Bottom Cores
• ATN625: With Laminate
Assembly None required.
*Intended for indoor use only
MADE IN THE
USA
COLOR
COMPOUNDING
TECHNOLOGY
Attenda®
Wall Mount Desk Desk Wall Mounted(D-WM)
OFFICE/MEETING ROOM
FURNITURE
Guest Chairs (CH-G) - Office Source Executive Mid Back Armless Ribbed Back Task Chair w/ Chrome base SKU: 05RG2WMAV
Task Chair (CH-T) - Office Source Frankly Contemporary Mesh Conference Chair 21621M, model OS-21621M
Conference Chair (CH-C) - Office Source Orion Mesh Back Conference Chair, model OSTW8003
Conference Table (TC) - Office Source OS Laminate 10'x 4' boat shaped conference table, model OS-OSTBTB32-OS237THALF.
!"#$%"#&''()"%#*+,-#'./"0#%)1)2+0#."&/,'2'3)"%4#.'#&'22"&.#-+.+#.'#)150'6"#7'$0#%/'55),3#"85"0)",&"9:7#$%),3#'$0#;"<%)."=#7'$>0"#+30""),3#.'#./"#&'22"&.)',#'?
-+.+#+%#-"%&0)<"-#),#'$0#@0)6+&7#@'2)&79
A"..),3% B"C"&.#+22 D&&"5.#D22#E''()"%
Guest Chairs (CH-G)
OS-21621M
Task Chair (CH-T)
Conference Chair (CH-C)
Conference Table (TC)
LEGEND
GYPSUM BOARD CEILING
CEILING MATERIAL
CEILING HEIGHT
CEILING TAG
1t
9'-0"
2 x 4 DROP-IN
FIXTURE
WALL MOUNTED LINEAR
DIRECT / INDIRECT
SUSPENDED LINEAR LIGHTING
UNDERCABINET LIGHT
ACT-1: "2x2"
RECESSED DOWNLIGHT
2 x 2 DROP-IN
FIXTURE
2 x 2 DROP-IN
SUNTUNNEL DIFFUSER
2 x 4 SURFACE
MOUNTED FIXTURE
ACCESS PANELC.7
MECHANICAL RETURN
MECHANICAL EXHAUST
MECHANICAL SUPPLY
A4.012
BB
CC
2 3 4
A4.01
A4.21
A4.21
A4.21
A4.21
A .1
A .1
A .1
A .1
RECEIVING /
STORAGE
MED LAB
SECURITY
C20.1
MED SUPPLY
MED ROOM
NURSE
STATION
MEETING
ROOM
NURSE
SUPERVISOR
NURSE
SUPERVISOR
PATIENT
ROOM/AII
PATIENT
ROOM
SHOWER
ROOM
PATIENT
ROOM
PATIENT
ROOM
DAY ROOM
CIRCULATION
C20
VAC STORE
40.1
DENTAL
OFFICE
D21
PSYCH
OFFICE
NURSE
SUPER /
EXAM ROOM
JANITOR
CLOSET
YTH TLT
EXAM ROOM
PSYCH
OFFICE
PSYCH
OFFICE
PSYCH
OFFICE
PSYCH
OFFICE
SHARED
OFFICE
YTH TLT
LOCKERS
BREAK
ROOM
STF TLT
STF TLT
HALLWAY
C30
KIT
41.1
YOUTH
WAITING
C10.1
ELEC. CLOSET
ACT-1
8' - 0"
ACT-1
8' - 0"
ACT-1
8' - 0"
ACT-1
8' - 6"
ACT-1
8' - 0"
GYP
8' - 0"
GYP
8' - 0"
GYP
8' - 0"
GYP
8' - 0"
GYP
8' - 0"
GYP
9' - 0"
ACT-1
8' - 0"
ACT-1
8' - 0"
ACT-1
8' - 0"ACT-1
8' - 0"
ACT-1
8' - 0"
GYP
7' - 6"
ACT-1
8' - 0"
A7.02
A7.02
GYP
7' - 10"
C.1C.1C.1C.1C.1
C.1
C.1
C.1
C.1
C.1
C.1
C.1 C.1
C.1
C.1
PRESERVE EXISTING
CEILING AS POSSIBLE
C.1
C.1
PRESERVE EXISTING
CEILING AS POSSIBLE
C.1
C.6
C.6
C.6
53.52.3 2.8
AA
A.6A.6
A4.21
A4.21
A6.02
SIM
A6.02
SIM
A6.02
SIM
DOWN LIGHTING PER ELEC.
CENTER LIGHT FIXTURE IN
ALUMINUM CLADDING PLANKS-
TYPICAL.
A6.03
DD
DOWN LIGHTING PER ELEC.
CENTER ;OGJT FIXTURE IN ALUMINUM
CLADDING PLANKS- TYPICAL
FRAMED METAL PANEL EDGE,
SEE STRUCTURAL AND
SIM
A4.31
A4.31
P4 P4
P4
P4
4.6
4.6
3.9
3.90.9 1.5
A4.21
A4.21
ZZZZ
CENTER LIGHTS ON
COUNTER BELOW @4'-8" O.C.
A7.02
Sim
C.7
C.7
C.7
C.7
C.7
C.7 2'
0"
2' - 0"
2'
0"
FA
C
E O
F W
AL
L
4'
8" 8'
0"
8'
0"
EQEQ EQ EQ
8'
0"
FA
C
E O
F W
AL
L
4'
2"
A6.04
A6.04
ALUMINUM CLADDING TO BE
RANDOMLY JOINED LENGTHS IN
THIS AREA. JOINTS SHALL BE
MINIMIUM 18" FROM ADJACENT
JOINTS- TYPICAL
STUCCO TO EXTEND TO
UNDERSIDE OF ALUMINUM
CLADDING, STUCCO
TERMINATION ANGLE TO MATCH
SOFFIT ANGLE.
(SIM.)/5 A6.04
A6.03
A6.02
A6.03
METAL (ALUMINUM) SOFFIT
CLADDING
/13 A6.02
STUCCO TO EXTEND TO
UNDERSIDE OF ALUMINUM
CLADDING, STUCCO
TERMINATION ANGLE TO MATCH
SOFFIT ANGLE.
(SIM.)
/5 A6.04
METAL (ALUMINUM) SOFFIT
CLADDING
A6.02
SIM
A6.02
SIM
A6.02
SIM
3 3
TYLER P CARLSON
E
PORTLAND, OREGON
R
S T
TA
G R E
I
TES
E
FO OR
N
OG
CDE RA
TE
TC
H I
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
LL
C
O
P Y
R
IG
H T
S W
S ix th A ve nu e, S ui te
P or tla nd , O
R
P ho ne : 5
/2
-4
8/
/2
:3 0:
A
M C
:\U se rs \w ill sl om an
\D oc um en ts \R ev it
\M ac
La re n
7_ w ill sl om an
.r vt
ENLARGED RCP -
PATIENT AREA
06.27.2025
A3.11
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
25015
M a c L
A R
E N
I N
F
IR
M A
R Y
P
H A
R M
A C
Y
R E
N O
V A
T
IO
N
N P
A C
IF
IC
H W
Y . W
O O
D B
U R
N , O
R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
KEY PLAN
GENERAL NOTES: R.C.P.
1. ALL CEILING HEIGHTS ARE RELATIVE TO TOP OF SLAB OR
SUBFLOOR, U.N.O.
2. REF. ELECTRICAL AND MECHANICAL PLANS FOR LOCATIONS OF
FIXTURES AND EQUIPMENT.
3. FIELD VERIFY EXISTING CEILING LAYOUTS PRIOR TO ANY WORK.
4. SUSPENSION SYSTEMS FOR NEW AND EXISTING SUSPENDED
GYPSUM BOARD CEILINGS SHALL BE MODIFIED TO FRAME AROUND
CEILING INSTALLED ITEMS. SEE MECHANICAL AND ELECTRICAL
DRAWINGS.
5. INSTALL BLOCKING AND BACKING FOR WINDOW COVERING TRACKS.
6. REMOVE EXISTING CEILINGS WHERE NEW CEILINGS ARE SHOWN TO
BE INSTALLED.
7. FOR TOP OF WALL DETAILS AND HEIGHT OF GYP BOARD ON WALLS,
SEE PLANS, PARTITION TYPES, AND DETAILS.
8. RECESSED FIXTURES ARE TO MAINTAIN RATINGS WHERE LOCATED
IN RATED CEILING ASSEMBLIES.
KEYNOTES
C.1 MAINTAIN EXISTING CEILING. NOTIFY ARCHITECT OF
CONDITIONS REQUIRING ADDITIONAL REMEDIATION AS
SALVAGE IN-SITU IS INTENDED
C.6 NEW SUNTUNNEL DIFFUSER
C.7 NEW 24x24 LOCKING (MEDIUM SECURITY) ACCESS
PANEL
1/4" = 1'-0"A3.11
1 ENLARGED RCP - INFIRMARY
1 County Comments 08/19/2025
3 ADDENDUM 02 08/14/2026
OWNER FURNISHED, SEE EQUIPMENT SCHEDULE BELOW
LEGEND
A .1
A .1
A .1
A .1
BED-PT
BED-PT
BED-PT
BED-PT
D-WM SF
RF
REF-V
PC
CH-PH
COPY
COPY
CH
T
CH
G
CH
G
CH
G
CH
G
CH
T
FL
FL
REF-F
PTD
SD
CT-UT
HK
PTD
SD
CH
T
CH
C
CH
C
CH
C
CH
C
CH
C
CH
C
CH
C
CH
C
CH
C
CH
T
CH
T
CH
T
CH
T
CH
T
CH
T
CH
T
CH
T
CH
T
TC
CH
T
CH
T
RECEIVING /
STORAGE
MED LAB
SECURITY
C20.1
MED SUPPLY
MED ROOM
NURSE
STATION
MEETING
ROOM
NURSE
SUPERVISOR
NURSE
SUPERVISOR
PATIENT
ROOM/AII
PATIENT
ROOM
SHOWER
ROOM
PATIENT
ROOM
PATIENT
ROOM
DAY ROOM
CIRCULATION
C20
VAC STORE
40.1
PSYCH
OFFICE
NURSE
SUPER /
EXAM ROOM
JANITOR
CLOSET
YTH TLT
75EXAM ROOM
PSYCH
OFFICE
PSYCH
OFFICE
PSYCH
OFFICE
PSYCH
OFFICE
SHARED
OFFICE
YTH TLT
LOCKERS
BREAK
ROOM
STF TLT
STF TLT
HALLWAY
C30
KIT
41.1
YOUTH
WAITING
C10.1
ELEC. CLOSET
DS
CPU
CPU
PHPH
OS2 OS2 N1 N2
N3
N4
N5
N6
N7
D
PRL
CF
WTC
CPU PH CPU CPU PH CPU
CPU
CPU
PH
CPU
CPU
PH
CPU
CPU
CH
T
FAX
CPU
D
D
BHC BHC
BHC BHC
BHT BHT
4.63.90.9 1.5
PTD-LR
SD-LR
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
LL
P Y
R
IG
H T
S W
S ix th A ve nu e, S ui te
P or tla nd , O
R
P h on e:
3/
4-
F
R
R E F E R E N
E
N L Y
8/
/2
:2 8:
A
M C
:\U se rs \w ill sl om an
\D oc um en ts \R ev it
\M ac
La re n
7_ w ill sl om an
.r vt
ENLARGED EQUIPMENT
PLAN - PATIENT AREA
06.27.2025
Q2.11
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
25015
M ac
L A
R E
N
IN
F
IR
M A
R Y
P
H A
R M
A C
Y R
E N
O V
A T
IO
N
N P
A C
IF
IC
H W
Y . W
O O
D B
U R
N , O
R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
KEY PLAN
GENERAL NOTES: EQUIPMENT
1. HALFTONED ELEMENTS ARE NOT IN CONTRACT, SHOWN FOR
REFERENCE AND DESIGN INTENT PURPOSES ONLY
2. COORDINATE W/ MANUFACTURER FOR LOCATIONS TO PROVIDE
WALL BACKING
GENERAL NOTES: EQUIPMENT
1. HALFTONED ELEMENTS ARE NOT IN CONTRACT, SHOWN FOR
REFERENCE AND DESIGN INTENT PURPOSES ONLY
2. COORDINATE W/ MANUFACTURER FOR LOCATIONS TO PROVIDE
WALL BACKING
EQUIPMENT LEGEND
TAG DESCRIPTION OFOI OFCI CFCI
(E) /
NEW
BED-PT PATIENT BED X NEW
BHC BEHAVIOR HEALTH CHAIR X NEW
BHT BEHAVIOR HEALTH TABLE X NEW
CF CENTRIFUGE X (E)
CH C CONFERENCE CHAIR X NEW
CH G GUEST CHAIR X NEW
CH T TASK CHAIR X NEW
COPY FLOOR-MOUNTED COPY/PRINTER X (E)
CPU COMPUTER X (E)
CT-UT UTILITY CART X (E)
D SIT/STAND DESK X NEW
DS DOCUMENT SCANNER X (E)
FAX FAX MACHINE X (E)
HK CRUTCH HOOKS X NEW
MICRO MICROWAVE X (E)
MIR-LR MIRROR X NEW
MON TELEVISION X NEW
PC PORTABLE COOLER X (E)
PH DESKTOP PHONE X (E)
PR UNDERCOUNTER PRINTER X (E)
PRL LABEL PRINTER X (E)
PTD PAPER TOWEL DISPENSER X NEW
PTD-LR PAPER TOWEL DISPENSER,
LIGATURE RESISTANT
X NEW
REF-F FREEZER/REFRIGERATOR X (E)
REF-V REFRIGERATOR-VACCINE X (E)
RF MINI-REFRIGERATOR X (E)
SD SOAP DISPENSER X NEW
SD-LR SOAP DISPENSER, LIGATURE
RESISTANT
X NEW
TC CONFERENCE TABLE X NEW
TV LARGE SCREEN TELEVISION X NEW
WB WHITE BOARD X NEW
WTC WALKIETALKIE CHARGING STATION X NEW
1/4" = 1'-0"Q2.11
1 EQUIPMENT - LEVEL 1 - PATIENT AREA