R4_LED Retrofit.pdf

PDF 3 MB Posted

Attached to
Boone AASF Modernize Lighting
Solicitation number
582-RFB-2490-2026
Issued by
Buchanan County, Iowa

About this file

This is a Request for Bids (RFB) document issued by the Iowa Department of Public Defense for an LED retrofit project at the Boone Army Aviation Support Facility (AASF) located at 700 Corporal Sneeden Drive, Boone, Iowa 50036. The project encompasses a comprehensive lighting modernization across 34,185 square feet, including removal of existing non-LED fixtures and installation of energy-efficient LED fixtures throughout the facility, exterior wall packs, and display lighting. The scope of work also requires installation of advanced lighting controls such as office occupancy sensors, dimmer switches, and photocell devices to maximize energy savings and optimize lighting performance. The RFB number is 582-RFB-2490-2026, with bids due by March 5, 2026, at 2:00 PM CST. A mandatory pre-bid walkthrough is scheduled for February 12, 2026, at 9:00 AM, with RSVP required to issuing officer Philip Payton at 515-975-6211 or philip.payton@dpd.iowa.gov. The project specifications include detailed lighting fixture requirements, with the file provided containing technical specifications for GOTHAM ARCHITECTURAL DOWNLIGHTING EVO8R 8" general illumination retrofit downlights, available in multiple lumen outputs (2000–3000 lumens) and color temperatures (2700K–4000K).

Bids must be submitted as a lump sum amount for the entire project. The solicitation is open to qualified bidders with no stated set-asides or restrictions limiting participation to disadvantaged enterprises or particular organizational categories. No incumbent vendors or current contractors are identified in the available materials. The project is funded through the Iowa Department of Public Defense, though the specific award value or budget range is not disclosed in the provided documentation. Payment terms require the State of Iowa to process invoices within sixty days of submission, in accordance with Iowa Code 8A.514. The RFB includes sixteen attachments providing detailed specifications for various LED fixture types, lighting controls, electrical data, and the complete Statement of Work necessary for bid preparation. The primary objectives are to reduce energy consumption, lower maintenance costs, and improve overall lighting quality at the facility.

View the file

Other files

File Type Posted
R1_LED Downlight.pdf PDF
LB1 dl_pgn_spec_WallPack.pdf PDF
F1-2_LED Flat Panel.pdf PDF
19A25-AASF1-001-11x17.pdf PDF
L6 LED_V70269_CS51922.pdf PDF
L7 ldn6.pdf PDF
L1 blt-2x4.pdf PDF
Footcandles.pdf PDF
Typical Office-Classroom Fixture.pdf PDF
1370207-event.pdf PDF
Boone_AASF_Lighing_Data.xlsx XLSX spreadsheet
R2-3_LED Linear Recessed.pdf PDF
L5 - AVX_led.pdf PDF
OC1 BCS-WS-CS-DT-300.pdf PDF
L4 clx-strip-light-spec-sheet.pdf PDF
SOW BooneAASF_ReLighting.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EVO8R

Luminaire Type:

Catalog Number:

Multiple Layers of Light

General Illumination Retrofit Downlight 8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

OVERVIEW

COM

PLIM

EN

TARY PRODU

CTS

• Bounding Ray™ optical design

• Unitized optics mechanically attach the light engine to the lower reflector for complete optical alignment.

• 45° cutoff to source and source image

• Fully serviceable and upgradeable lensed LED light engine

• 70% lumen maintenance at 60,000 hours

• 2.5 SDCM; 85 CRI typical, 90+ CRI optional

• Fixtures are wet location, covered ceiling

• Available with 10% dimming, 1% dimming, or dim to dark

• Batwing distribution with feathered edges provides even illumination on horizontal and vertical surfaces

Feature Set

Distribution

Superior Perfomance very narrow

0.5 S:MH

narrow

0.7 S:MH

wide

1.2 S:MH

medium

0.9 S:MH

medium wide

1.0 S:MH

Nominal Lumens 2000 2500 3000

Delivered Lumens 2,287 2,964 3,398

Wattage 31.6 41.1 47.1

Efficacy 72.5 72 72.2

2000 - 3000 lumens

Coordinated Apertures | Multiple Layers of Light

EVO + Incito — Multiple Layers of LightGeneral Illumination Layer | EVO High Center Beam Layer | Incito

Downlight Adjustable Open Wallwash

Lensed Wallwash

Cylinder Pinhole Bevel Hyperbolic

MRI Surgical Suite

Patient Room

Dynamic Food Service Vandal/Tamper Clean Room Shower Steam Room

Core

Healthcare

Special Applications https://gothamlighting.acuitybrands.com

General Illumination Retrofit Downlight8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

Luminaire Type:

Catalog Number:

ORDERING NOTES

1.Not available with finishes.
2.Not available with EL/ELR options.
3.Supplied with factory installed step down transformer.
4.Refer to TECH-240 for compatible dimmers.
5.Not available with nLight® and XPoint options.
6.Must specify voltage.
7.For use with different reflector finish only (i.e. AR, PR, WTR, GR

options). Not available with WR (white reflector).

8. For use with different reflector finish only (i.e. AR, PR, WTR, GR options). Not available with BR (black reflector).

9. For use with generator supply EM power. Will require an emergency hot feed and normal hot feed.

10. Fixture begins at 80% light level. Must be specified with eldoLED drivers and NLT or

NLTER.

11. Not available DALI or DMX drivers. Not available with CP or N80 options. Not recom-mended for metal ceiling installations.

ACCESSORIES — order as separate catalog numbers (shipped separately)

CTA4-8 YK Ceiling thickness adapter (extends mounting frame to accommodate ceiling thickness up to 5"). Adds ~4" to fixture height.

ISD BC 0-10V wallbox dimmer. Refer to ISD-BC.

EXAMPLE: EVO8R 35/30 AR MWD LSS 277 EZ1

Series Color Temperature Nominal Lumen Values Reflector & Flange Color Distribution Finish Voltage

EVO8R 27/ 2700 K

30/ 3000 K 35/ 3500 K 40/ 4000 K

20 2000 lumens 25 2500 lumens 30 3000 lumens

AR Clear PR Pewter WTR Wheat GR Gold WR1 White BR1 Black WRAMF1 White Anti-microbial

VND Very Narrow (0.5 s/mh) ND Narrow (0.7 s/mh) MD Medium (0.9 s/mh) MWD Medium wide (1.0 s/mh) WD Wide (1.2 s/mh)

LSS Semi-specular LD Matte-diffuse LS Specular

3472,3

Driver4 Control Interface Options

GZ10 0-10V driver dims to 10% GZ1 0-10V driver dims to 1% EZ10 eldoLED 0-10V ECOdrive. Linear dimming to 10% min.

EZ1 eldoLED 0-10V ECOdrive. Linear dimming to 1% min.

EZB eldoLED 0-10V SOLOdrive.

Logarithmic dimming to <1%.

EDAB5 eldoLED SOLOdrive DALI. Loga-rithmic dimming to <1%.

EDXB5 eldoLED POWERdrive DMX with

RDM (remote device manage-ment). Square Law dimming to <1%. Includes termination resistor.

ECOD5 Lutron Ecosystem digital Hi-Lume 1% soft-on, fade to black. Maximum 2500 lumens.

NLT6 nLight® dimming pack controls

NLTER2,6,9 nLight® dimming pack controls emergency circuit

NLTAIR211 nLight® Air enabled NLTAIRER22,9,11 nLight® AIR Dimming

Pack Wireless Controls.

Controls fixtures on emergency circuit

EXA1 XPoint Wireless, eldoLED 0-10V ECOdrive. Linear dimming to 1%. Refer to XPoint tech sheet.

EXAB XPoint Wireless, eldoLED 0-10V SOLOdrive.

Logarithmic dimming to <1%. Refer to XPoint tech sheet.

SF Single fuse. Specify 120V or 277V.

TRW7 White painted flange TRBL8 Black painted flange EL Emergency battery pack, 10W, with integral test switch ELR Emergency battery pack, 10W, with remote test switch ELSD Emergency battery pack, 10W, with self-diagnostics, integral test switch ELRSD Emergency battery pack, 10W, with self-diagnostics, remote test switch E10WCP Emergency battery pack, 10W Constant Power, CA Title 20 compliant with integral test switch E10WCPR Emergency battery pack, 10W Constant Power, CA Title 20 compliant with remote test switch N8010 nLight® Lumen Compensation 90CRI High CRI (90+)

RRL__ RELOC®-ready Luminaire connectors enable a simple and consistent factory installed option across all ABL luminaire brands. Available only with RRLA, RRLB, RRLAE, and RRLC12S. Refer to RRL spec sheet on www.acuitybrands.com for RELOC product specifications. Above ceiling access required.

A+ Capable options indicated by this color background.

ORDERIN

G IN

FORM

ATION

https://gothamlighting.acuitybrands.com https://gothamlighting.acuitybrands.com/-/media/abl/gothamlighting/files/resources/technical-bulletins/tech-240.pdf http://www.acuitybrandslighting.com/library/SYN/documents/SpecSheets/ISD_BC.pdf http://www.acuitybrands.com

General Illumination Retrofit Downlight8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

Optical Assemby Fully serviceable and upgradeable lensed LED light engine suitable for field maintenance or service from below the ceiling.

Optical design is a Bounding Ray™ design with 45° cutoff to source and source image. Top-down flash characteristic for superior glare control.

Unitized optics shall have mechanical attachment of the light engine to the lower reflector for complete optical alignment.

Electrical The luminaire shall operate from a 50 or 60 Hz ±3 Hz AC line over a voltage ranging from 120 VAC to 277 VAC. The fluctuations of line voltage shall have no visible effect on the luminous output.

The luminaire shall have a power factor of 90% or greater at all standard operating voltages and full luminaire output.

Sound Rated A+. Driver shall be >80% efficient at full load across all input voltages.

Input wires shall be 18AWG, 300V minimum, solid copper.

Controls Luminaire shall be equipped with interface for nLight wired or wireless network with integral power supply as per specification.

Dimming The luminaire shall be capable of continuous dimming without perceivable stroboscopic flicker as measured by flicker index (ANSI/IES RP-16-10) over a range of 100 – 10%, 100 – 1.0% or 100 – 0.1% of rated lumen output with a smooth shut off function to step to 0%.

eldoLED LED drivers shall conform to IEEE P1789 standards. Alternatively, manufacturers must demonstrate conformance with product literature and testing which demonstrates this performance. Systems that do not meet IEEE P1789 will not be considered.

Driver is inaudible in 24dB environment, and stable when input voltage conditions fluctuate over what is typically experienced in a commercial environment.

Construction Compatible only with Gotham open style mounting frames. Originally installed mounting frame must be a Gotham GRS, GRSF, GRSH, AFV, or LGFV series frame. See frame compatibility table.

Junction box capacity: 8 (4 in, 4 out) 12AWG rated for 90°C

Luminaires shall be suitable for installation in ceilings up to 1½" thick. (specify ceiling thickness adapter to extend frame to accommodate ceiling thickness up to 5")

The assembly and manufacturing process for the luminaire shall be designed to assure all internal components are adequately supported to withstand mechan-ical shock and vibration.

25°C ambient temperature standard (1/2" clearance on all sides from non-combustible materials in non-IC applications, unless marked spacing noted other-wise). For use in insulated ceilings, a 3" clearance on all sides from insulation is required (unless marked spacing noted otherwise).

Listings Fixtures are CSA certified to meet US and Canadian standards: All fixtures manufactured in strict accordance with the appropriate and current requirements of the “Standards for Safety” to UL, wet location covered ceiling.

Photometrics LEDs tested to LM-80 standards. Measured by IESNA Standard LM-79-08 in an accredited lab. Lumen output shall not decrease by more than 30% over the minimum operational life of 60,000 hours.

Color appearance from luminaire to luminaire of the same type and in all configurations, shall be consistent both initially and at 6,000 hours and operate with-in a tolerance of <2.5 MacAdam ellipse as defined by a point at the intersection of the CCT line and the black body locus line in CIE chromaticity space.

Buy American Act This product is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations.

Please refer to www.acuitybrands.com/buy-american for additional information.

Warranty 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions

Note:

Actual performance may differ as a result of end user environment and application.

All values are design or typical values, measured under laboratory conditions at 25 °C.

SPECIFICATION

S

Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.

•All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency
•This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background*
•This luminaire is part of an A+ Certified solution for nLight® control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control

options marked by a shaded background* To learn more about A+, visit www.acuitybrands.com/aplus.

*See ordering tree for details https://gothamlighting.acuitybrands.com https://www.acuitybrands.com/resources/buy-american http://www.acuitybrands.com/support/warranty/terms-and-conditions www.acuitybrands.com/aplus

General Illumination Retrofit Downlight8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

Tables of Use

Delivered Lumens = 1.25 x P x LPW

P = Output power of emergency driver. P = 10W for PS1055CP

LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet.

How to Estimate Delivered Lumens in Emergency Mode

Distributions

Nomenclature Beam Angle Field Angle

VND 30 64

ND 44 69

MD 54 82

MWD 67 89

WD 71 92

Reflector Finish Multiplier

Reflector Finish Multiplier

LS - Specular 1

LSS - Semi Specular 0.956

WR - White 0.87

LD - Matte Diffuse 0.85

BR - Black 0.73

EVO - eldoLED Driver Default Dimming Curve

Nomenclature Min Dimming Driver Dim Curve Control Dim Curve

EZ10 10% Linear Linear/Logarithmic

EZ1 1% Linear Linear/Logarithmic

EXA1 1% Linear Linear/Logarithmic

EZB <1% Logarithmic Linear

EDAB <1% Logarithmic Linear

EXAB <1% Logarithmic Linear

EDXB <1% Square Linear

Driver Control Provided

(note: 347V/UVOLT versions provided with 347 option selected)

Nomenclature Description NLT NLTER NLTAIR2 NLTAIRER2

GZ10 0-10V driver dims to 10% nPP16 D EFP nPP16 D ER EFP RPP20 D 24V G2 RPP20 D 24V ER G2

GZ1 0-10V driver dims to 1% nPP16 D EFP nPP16 D ER EFP RPP20 D 24V G2 RPP20 D 24V ER G2

EZ10 eldoLED 0-10V ECOdrive nPS 80 EZ nPS 80 EZ ER RPP20 D 24V G2 RPP20 D 24V ER G2

EZ1 eldoLED 0-10V ECOdrive nPS 80 EZ nPS 80 EZ ER RPP20 D 24V G2 RPP20 D 24V ER G2

EZB eldoLED 0-10V SOLOdrive nPS 80 EZ nPS 80 EZ ER RPP20 D 24V G2 RPP20 D 24V ER G2

Lumen Output Multiplier

CRI CCT Multplier

2700K 0.96

3000K 1.00

3500K 1.00

4000K 1.01

2700K 0.80

3000K 0.83

3500K 0.85

4000K 0.87

General Illumination Retrofit Downlight8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

DIM

EN

SION

AL DATA

Standard Drive Open Frame CP

8 [21.9]

Aperture: 7-7/8 (20.1) Ceiling Opening: 8-7/8 (21.5) Overlap Trim: 9-1/4 (23.5)

Aperture: 7-7/8 (20.1)

Ceiling Opening: 8-7/8 (21.5)

Overlap Trim: 9-1/4 (23.5)

General Illumination Retrofit Downlight8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

Photom etry

EVO8R 30/20 AR MWD LS INPUT WATTS: 31.5, DELIVERED LUMENS: 2287.4, LPW= 72.6, 1 S/MH, TEST NO. LTL27655P301

EVO8R 30/25 AR MWD LS INPUT WATTS: 41, DELIVERED LUMENS: 2964, LPW = 72.3, 0.98S/MH, TEST NO. LTL27654P200

EVO8R 30/30 AR MWD LS INPUT WATTS: 42.3, DELIVERED LUMENS: 3125.8, LPW=73.8, 0.99 S/MH, TEST NO. 27848P202

PRINT DATE: TEST NO:

MANUFACTURER:

LUMINAIRE CATALOG NO.:

LUMINAIRE DESCRIPTION:

LUMENS PER LAMP:

[_LAMPTYPE]

[_FAMILY]

[_PRODUCTID]

[_APERTURE]

[_MOUNTING]

[_TOTALLUMINAIRELUMENS]

[_INPUTWATTAGE]

[_PHYSICALDIMENSIONS]

September 12, 2019 LTL27655P301

Gotham Architectural Lighting

EVO8CYL 30/20 AR MWD LS

8" EVO 3000K 80 CRI 2000LM

2287.397

LED

EVO CYL 8 Downlight e828ec00-35e9-42ee-96f6-aa95fda04992

Recessed

2287.4

31.55

-0.67, -0.67, 0

0° 20°

40°

60°

80°

Ave Lumens

Zone Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

1520.8

2072.7

2286.3

2287.4

0.0

2287.4

66.5

90.6

99.9

100.0

0.0

*100.0

*Efficiency

Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10%

R C

R

50% beam -

53.2°

10% beam -

81.3°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

71.8

38.6

24.1

16.4

11.9

5.5

7.5

9.5

11.5

13.5

35.9

19.3

12.0

8.2

6.0

9.4

12.9

16.3

19.8

23.2

7.2

3.9

2.4

1.6

1.2

Spacing to Mounting Height:1.0

PRINT DATE: TEST NO:

MANUFACTURER:

LUMINAIRE CATALOG NO.:

LUMINAIRE DESCRIPTION:

LUMENS PER LAMP:

[_LAMPTYPE]

[_FAMILY]

[_PRODUCTID]

[_APERTURE]

[_MOUNTING]

[_TOTALLUMINAIRELUMENS]

[_INPUTWATTAGE]

[_PHYSICALDIMENSIONS]

September 12, 2019 LTL27654P200

Gotham Architectural Lighting

EVO8R 30/25 AR MWD LS

8" EVO 3000K 80 CRI 2500LM SPECULAR, RETROFIT

2964.136

LED

EVO R 8 Downlight

16478d56-6d1d-4e12-acf2-42eb9f4f5004

Recessed

2964.1

41.14

-0.67, -0.67, 0

0° 20°

40°

60°

80°

Ave Lumens

Zone Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

2036.1

2716.5

2962.6

2964.1

0.0

2964.1

68.7

91.6

99.9

100.0

0.0

*100.0

*Efficiency

Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10%

R C

R

50% beam -

51.5°

10% beam -

79.5°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

98.7

53.1

33.1

22.6

16.4

5.3

7.2

9.2

11.1

13.0

49.3

26.5

16.5

11.3

8.2

9.1

12.5

15.8

19.1

22.4

9.9

5.3

3.3

2.3

1.6

Spacing to Mounting Height:1.0

PRINT DATE: TEST NO:

MANUFACTURER:

LUMINAIRE CATALOG NO.:

LUMINAIRE DESCRIPTION:

LUMENS PER LAMP:

[_LAMPTYPE]

[_FAMILY]

[_PRODUCTID]

[_APERTURE]

[_MOUNTING]

[_TOTALLUMINAIRELUMENS]

[_INPUTWATTAGE]

[_PHYSICALDIMENSIONS]

September 12, 2019 LTL27848P202

Gotham Architectural Lighting

EVO8R 30/30 AR MWD LS

8" EVO 3000K 80 CRI 3000LM SPECULAR, RETROFIT

3125.747

LED

EVO R 8 Downlight dd71c23d-109e-4cf4-b2de-e3e30a55bcb6

Recessed

3125.8

42.3

-0.63, -0.63, 0

0° 20°

40°

60°

80°

Ave Lumens

Zone Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

2152.4

2868.6

3123.1

3125.7

0.0

0.0

0.0

0.0

3125.7

68.9

91.8

99.9

100.0

0.0

0.0

0.0

0.0

*100.0

*Efficiency

Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10%

R C

R

50% beam -

51.6°

10% beam -

79.3°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

104.2

56.1

34.9

23.8

17.3

5.3

7.3

9.2

11.1

13.1

52.1

28.0

17.5

11.9

8.7

9.1

12.4

15.8

19.1

22.4

10.4

5.6

3.5

2.4

1.7

Spacing to Mounting Height:1.0

General Illumination Retrofit Downlight8"

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2023 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/27/23 Specifications subject to change without notice.

N

LIGH

T AIR

N

LIGH

T nLight® AIR is the ideal solution for retrofit or new construction spaces where adding communication wiring is cost prohibitive. The integrated nLight AIR rPP20 Power Pack is part of each EVO Luminaire ordered with the NLTAIR option.

These individually addressable controls offer the ultimate in flexibility during initial setup and for space repurposing.

nLight® The nLight® solution is a digital networked lighting control system that provides both energy savings and increased user configurability by cost effectively integrating time-based, daylight-based, sensor-based and manual lighting control schemes.

CAT-5e Cable Line Power Low Voltage

Dimming Wires

Wiring Key nCM

Fixtures ordered without the NLT option nPODM

Fixtures ordered with the NLT option nCM nPODM nPS 80 EZ or nPP16 D rPP20 rPODB rCMS

Fixtures ordered without the NLTAIR option

CLAIRITYTM Pro Mobile App rPODB CLAIRITYTM Pro

Mobile App

Fixtures ordered with the NLTAIR option

+24v DC Aux Line Power Low Voltage

Dimming Wires

Wiring Key nLight® AIR Control Accessories Order as separate catalog number. Visit nLight AIR.

Wall Switches

On/Off single pole

On/Off two pole

On/Off & raise/lower single pole

On/Off & raise/lower two pole

Model Number rPODB (color) G2 rPODB 2P (color) G2 rPODB DX (color) G2 rPODB 2P DX (color) G2 nLight® Wired Control Accessories Order as separate catalog number. Visit nLight.

Wall Switches

On/Off single pole

On/Off two pole

On/Off & raise/lower single pole

On/Off & raise/lower two pole

Graphic touchscreen

Photocell Controls

Dimming

Model Number nPODM (color) nPODM 2P (color) nPOD DX (color) nPODM 2P DX (color) nPOD GFX (color) nCM ADCX nLight® Wired Control Accessories (cont.)

nLight® AIR Control Accessories (cont.)

Occupancy Sensors (PIR/dual tech)

Small motion 360o , ceiling

Large motion 360o , ceiling

Wide View

Wall switch with raise/lower

Cat-5 Cables (plenum rated)

10’, CAT5

15’, CAT5

Occupancy Sensors (PIR/dual tech)

Small motion 360o , ceiling

Large motion 360o , ceiling

Model Number nCM 9 / nCM PDT 9 nCM 10 / nCM PDT 10 nWV 16 / nWV PDT 16 nWSX LV DX / nWSX PDT LV DX

CAT5 10FT J1

CAT5 15FT J1

Model Number rCMS 9 / rCMS PDT 9 rCMS 10 / rCMS PDT 10

Possibilites for nLight® wired

Possibilites for nLight® AIR https://gothamlighting.acuitybrands.com https://www.acuitybrands.com/brands/lighting-controls/nlight https://www.acuitybrands.com/brands/lighting-controls/nlight

Text Field 2:
Text Field 3:
Text Field 4:
Text Field 5:
Text Field 6:
Text Field 7:
Text Field 8:
Text Field 9:
Text Field 10:
Text Field 11:
Text Field 13:
Text Field 14:
Text Field 15:
Text Field 16:

File details come from the government source that posted it. Updated .