L1 blt-2x4.pdf
PDF 3 MB Posted
- Attached to
- Boone AASF Modernize Lighting
- Solicitation number
- 582-RFB-2490-2026
- Issued by
- Buchanan County, Iowa
About this file
This is a Request for Bids (RFB) document issued by the Iowa Department of Public Defense for a comprehensive LED lighting retrofit project at the Boone Army Aviation Support Facility (AASF) located at 700 Corporal Sneeden Drive, Boone, Iowa 50036. The project encompasses the complete modernization of lighting systems across 34,185 square feet, including removal of existing non-LED fixtures and installation of energy-efficient LED fixtures throughout the facility, exterior wall packs, and display lighting. The scope of work also incorporates advanced lighting controls such as office occupancy sensors, dimmer switches, and photocell devices to maximize energy savings and optimize lighting performance. The mandatory pre-bid walkthrough is scheduled for Thursday, February 12, 2026, at 9:00 AM, with RSVP required to issuing officer Philip Payton at 515-975-6211 or philip.payton@dpd.iowa.gov. Bids must be submitted as a lump sum amount and are due by March 5, 2026, at 2:00 PM CST.
The solicitation documentation does not specify a set-aside designation or budget range, indicating the procurement is open to qualified bidders without restrictions to disadvantaged enterprises or particular organizational categories. No incumbent vendors or current contractors are identified in the available materials. Payment terms allow the State of Iowa sixty days from invoice submission to process payment, as specified in Iowa Code 8A.514. Bidders must meet specified insurance requirements, authorize release of information, and acknowledge federal terms and conditions. The project is funded through the Iowa DPD, with the specific award value or budget not disclosed in the provided summary. The RFB includes sixteen attachments providing detailed specifications for various LED fixture types, lighting controls, electrical data, and the complete Statement of Work necessary for bid preparation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| R1_LED Downlight.pdf | ||
| LB1 dl_pgn_spec_WallPack.pdf | ||
| F1-2_LED Flat Panel.pdf | ||
| 19A25-AASF1-001-11x17.pdf | ||
| L6 LED_V70269_CS51922.pdf | ||
| R4_LED Retrofit.pdf | ||
| 1370207-event.pdf | ||
| Boone_AASF_Lighing_Data.xlsx | XLSX spreadsheet | |
| R2-3_LED Linear Recessed.pdf | ||
| L5 - AVX_led.pdf | ||
| L7 ldn6.pdf | ||
| Footcandles.pdf | ||
| Typical Office-Classroom Fixture.pdf | ||
| OC1 BCS-WS-CS-DT-300.pdf | ||
| L4 clx-strip-light-spec-sheet.pdf | ||
| SOW BooneAASF_ReLighting.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMERCIAL INDOOR BLT-2X4
BLT Series LED
2BLT4
2' x 4'
LED
Catalog Number
Notes
TypeFEATURES & SPECIFICATIONS INTENDED USE —The BLT Best-in-Value Low Profile LED luminaire features a popular center basket design that offers a clean, versatile style and volumetric distribution. High efficacy LED light engines deliver energy savings and low maintenance compared to traditional sources. An extensive selection of configurations and options make the BLT the perfect choice for many lighting applications including schools, offices and other commercial spaces, retail, hospitals and healthcare facilities.
The low profile BLT design (2-3/8") also makes it an excellent choice for renovation projects.
CONSTRUCTION — Prior to fabrication, BLT components are coated with a proprietary paint blend and die-formed for dimensional consistency.
The BLT reflector is available in both smooth and ribbed finishes. Choose RB from the fixture style section below for a ribbed finish.
End plates contain easy-to-position integral T-bar clips for securely attaching the luminaire to the T-grid. For additional T-grid security, optional screw on T-bar clips are available.
Diffusers are extruded from impact modified acrylic for increased durability.
LED boards and drivers are accessible from the plenum.
OPTICS — Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions and vertical and horizontal work surfaces – rendering the interior space, objects and occupants in a more balanced, complimentary luminous environment. High performance extruded acrylic diffusers conceal LEDs and efficiently deliver light in a volumetric distribution. Four diffuser choices available - curved and square designs with ribbed or a smooth frosted finish.
ELECTRICAL — Long-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. 80% LED lumen maintenance at 60,000 hours (L80/60,000). Color Variation within 3-step MacAdam ellipse (3SDCM).
Non-Configurable BLT: Generic 0-10 volt dimming driver. Dims to 10% Configurable BLT: available in High Efficiency (HE) versions for applications where a lower wattage (over the standard product) is required. The High Efficiency versions deliver >130 LPW and can be specified via the Lumen Package designations in the Ordering Information below.
eldoLED driver options deliver choice of dimming range, and choices for control, while assuring flicker-free, low-current inrush, 89% efficiency and low EMI.
Optional integrated nLight®controls make each luminaire addressable - allowing it to digitally communicate with other nLight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Connection to nLight is simple.
It can be accomplished with integrated nLight AIR wireless RIO, RES7 sensors, or through standard Cat-5 cabling. nLight offers unique plug-and-play convenience as devices and luminaires automatically discover each other and self-commission.
nLight AIR is commissioned easily through an intutitive mobile app.
Lumen Management: Unique lumen management system (option N80) provides on board intelligence that actively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighting.
Step-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance.
SENSOR— Integrated sensor (individual control): Sensor Switch MSD7ADCX ((Passive infrared (PIR)) or MSDPDT7ADCX ((PIR/Microphonics Dual Tech (PDT)) integrated occupancy sensor/automatic dimming photocell allows the luminaire to power off when the space is unoccupied or enough ambient light is entering the space. See page 4 for more details on the integrated sensor.
Integrated Sensor (nLight Wired Networking): This sensor is nLight-enabled, meaning it has the ability to communicate over an nLight network. When wired, using CAT-5 cabling, with other nLight-enabled sensors, power packs, or WallPods, an nLight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. See page 4 for the nLight sensor options.
Integrated Smart Sensor (nLight Air Wireless Platform): The RES7 sensor is nLight AIR enabled, meaning it has the ability to communicate over the wireless nLight control platform. It is available with an automatic dimming photocell, and either a digital PIR or a microphonics (PDT) dual technology occupancy sensor. It pairs to other luminairs and wall switches through our mobile app, CLAIRITY+, which allows for simple sensor adjustment. See page 4 for more details on the Integrated Smart Sensor.
Integrated Wireless Sensor (single room control): Sensor Switch VERTEX JOT or JOTVTX15 luminaire-embedded occupancy and ambient light sensor allows the luminaire to power off when the space is unoccupied or when enough ambient light is entering the space. See page X for more details on the integrated wireless sensor.
INSTALLATION — The BLT's low profile design of only 2-3/8" provides increased installation flexibility especially in restrictive plenum applications. Designed for use in NEMA standard Type G (1" & 15/16") , NFG (9/16"), and SS (9/16") grid ceilings. Consult factory about other ceiling types.
For recessed mounting in hard ceiling applications, Drywall Grid Adapters (DGA) are available as an accessory.
See Accessories section. Suitable for damp location.
LISTINGS — CSA Certified to meet U.S. and Canadian standards. IC rated. Tested in accordance with ISO 14644-1; suitable for ISO Class 5-9 positive and negative pressure clean rooms.
DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.
org/QPL to confirm which versions are qualified.
BUY AMERICAN — Product with the BAA option is assembled in the USA and meets the Buy America(n) govern-ment procurement requirements under FAR, DFARS and DOT.
Please refer to www.acuitybrands.com/buy-american for additional information.
WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements in this speci-fication sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions NOTE: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Specifications
Length: 47-3/4 (121.2)
Width: 23-3/4 (60.3)
Depth: 2-3/8 (6.0)
Depth with Air supply/return: 2-3/4 (6.9)
All dimensions are inches (centimeters) unless otherwise specified.
Static
Air Supply/Return
Ribbed Reflector Option
ADP Diffuser Option
Buy American
ISO
Class 5-9
Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.
• All configurations of this luminaire meet the Acuity Brands' specification for chromatic consistency
• This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background*
• This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background*
To learn more about A+, visit www.acuitybrands.com/aplus.
*See ordering tree for details
Embed nLight controls today. Prepare for tomorrow.
User-friendly install Scalability
Enhanced energy savings Space configuration
Code compliance Future-ready
Now Tomorrow
Ordering Tree
DIGITAL NAVIGATION
nLight Platform Sensor Switch JOT Photometrics Performance Data http://www.designlights.org/QPL http://www.designlights.org/QPL http://www.acuitybrands.com/buy-american http://www.acuitybrands.com/support/warranty/terms-and-conditions http://www.acuitybrands.com/aplus
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4'
ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: 2BLT4 40L ADP EZ1 LP840
2BLT4
Series Fixture Style Air function Lumens ‡ Diffuser Voltage Driver Color temperature
2BLT4 2x4 BLT (blank) Smooth Reflector
RB Ribbed Reflector
(blank) Static A Air supply/ return ‡
Standard efficiency
(>100 LPW)
30L 3000 40L 4000 48L 4800 60L 6000 72L 7200 85L 8500 100L 10000 120L 12000
High efficiency ‡
(>130 LPW)
30LHE 3000
40LHE 4000
48LHE 4800
60LHE 6000
72LHE 7200
85LHE 8500
ADP Curved, ribbed ADSM Curved, smooth SDP Square, ribbed SDSM Square, smooth LUGR Low UGR lens‡ Includes trim rings to match sensored version ADPT Curved, ribbed ADSMT Curved, smooth SDPT Square, ribbed SDSMT Square, smooth LUGRT Low UGR lens with trim‡
(blank) MVOLT 120 120V 277 277V 347 347V ‡
EZ1 eldoLED dims to 1% (0-10 volt dimming)
GZ1 Dims to 1% (0-10V dimming)
GZ10 Dims to 10% (0-10V dimming)
SLD Step-level dimming ‡
LP830 82CRI, 3000 K
LP835 82CRI, 3500 K
LP840 82CRI, 4000 K
LP850 82CRI, 5000 K
LP930 90CRI, 3000K
LP935 90CRI, 3500K
LP940 90CRI, 4000K
LP950 90CRI, 5000K
nLight Interface Control ‡ nLight Wired (blank) no nLight ® interface N80 nLight with 80% lumen management N80EMG nLight with 80% lumen management
For use with generator supply EM power ‡ N100 nLight without lumen management N100EMG nLight without lumen management
For use with generator supply EM power ‡ nLight Wireless (blank) no nLight AIR ® interface NLTAIR2 nLight AIR Generation 2 enabled ‡ nLight Wired ‡ (blank) No sensor control NES7 nLight™ nES 7 PIR integral occupancy sensor NESPDT7 nLight™ nES PDT 7 dual technology integral occupancy control NES7ADCX nLight™ nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell NESPDT7ADCX nLight™ nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell nLight Wireless
RES7 nLight AIR control with PIR integral occupancy sensor and automatic dimming photocell ‡
RES7PDT nLight AIR control with PDT dual technology integral occupancy sensor and automatic dimming photocell ‡
RIO nLight AIR radio module without sensor ‡ RES7EM nLight AIR PIR integral occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection ‡
RES7PDTEM nLight AIR microphonics dual technology occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection ‡
RIOEM nLight AIR radio module less sensor, with UL924 Emergency Operation, via power interrupt detection ‡
Individual Control MSD7ADCX PIR integral occupancy sensor with automatic dimming control photocell ‡ MSDPDT7ADCX PDT integral occupancy sensor with automatic dimming control photocell ‡ JOT Wireless room control with
“Just One Touch" pairing ‡ JOTVTX15 Wireless occupancy sensor with
“Just One Touch" pairing ‡
Standy Mode Options
NOC NOC Occupancy sensor disabled ‡
BDP Disconnect Plug
EL7L 700 lumen battery pack (Noncompliant with CA T20) ‡
EL14L 1400 lumen battery pack (Noncompliant with CA T20) ‡
E10WLCP EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20 MAEDBS ‡
CP Chicago plenum ‡ BGTD Bodine Generator Transfer Device ‡ PWS1836 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit PWS1846 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuit PWS1846 PWSLV Two cables: one 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuits; one 6' pre-wire, 3/8" diameter, 18 gauge ‡
PWS1856LV 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit w/low voltage wires ‡
GLR Fast-blowing fuse ‡ GMF Slow-blowing fuse ‡ NPLT Narrow pallet RRL_ RELOC®-ready luminaire ‡ LATC Earthquake clip WH Glossy White DWAM Anti-Microbial paint JP14 Job packaging ‡ JP22 Job packaging ‡ IP5X Gasketed diffuser compartment to meet IP5X rating ‡ BAA Buy America(n) Act Compliant
NOTE: ‡ indicates option value has ordering restrictions. Please reference the Option Value Ordering Restictions chart on the next page. Options are sorted alphanumerically.
A+ Capable options indicated by this color background.
http://www.lithonia.com
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
‡ Option Value Ordering Restrictions
Option value Restriction 347 Not available with SLD, EL7L, EL14L, or E10WLCP options.
A Not available with RB fixture style, consult factory for air flow data. If a job pack is selected, use JP14 only.
BGTD Not available with TD, JOT, JOTVTX15 sensor options or emergency battery options. Must specify voltage. Requires BSE labeling, voltage specific. Consult factory for options. Example:
BGTD BSE10.
Controls Must specify diffuser with trim rings.
CP Not available with N80, N80EMG, N100, N100EMG, PWS1836, PWS1846, PWS1846 PWSLV or PWS1856LV.
EL14LSD, E10WLCP, EL7L, EL14L When using pre-wire option, use PWS1846 or PWS1846 PWSLV. For more information, please see the PSSD2 specification sheet.
FAO EZ1 driver required. Not available with USPOM, FAO or lumen packages > 6000LM. FAO restricts use of external Dimming controls. See chart on page 3 for additional details.
GLR, GMF Must specify voltage. 120 or 277, with GLR and GMF fusing.
IP5X Not available with air supply/return or Wired Networking (NES_) and Individual Control (MSD_) sensors.
JOT, JOTVTX15 Not available with standard efficiency 85L, 85LHE, 100L or 120L lumen options. Not available with SLD, nLight, NLTAIR2, NOC, or BGTD options.
JP14 Only available on fixtures with NES7, NESPDT7, NESPDT7ADCX, MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO, JOT,JOTVTX15. Not available when 'A' air supply/return function and sensor options are combined.
JP22 Not available with option: NES7, NESPDT7, NESPDT7ADCX, MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO, JOT, JOTVTX15. Not available when 'A' air supply/return function option.
Lumens Approximate lumen output. For high Efficiency, all versions may not achieve 130+ LPW. Refer to photometry on www.acuitybrands.com. Air supply/return option, 90 CRI, and versions with integral sensor trim rings may not achieve 130 LPW.
LUGR, LUGRT Due to the unique optics used to drive the low UGR distribution, the LUGR lens is not uniformly lit and presents visible striping.
MSD7ADCX, MSDPDT7ADCX Only available with EZ1 driver option. 0-10v dimming wires not accessible via access plate.
NES7, NESPDT7, NES7ADCX, NESPDT7ADCX Requires N80, N80EMG, N100, or N100EMG. Only available with EZ1 driver.
NLTAIR2 Must order with nLight Wireless option from Control section. Not available with GZ10 driver. Not available with 85L, 85LHE, 100L, or 120L options.
NOC Can only be ordered in conjunction with EZ1 or GZ1, NLTAIR2, RES7/RES7PDT. Occupancy sensor disabled at factory but can be re-enabled upon commissioning.
N80EMG, N100EMG nLight EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture.
RES7, RES7PDDT, RIO See UL 924 Sequence of Operation chart on page 3. When combined with the EZ1 option, can be used as a normal power sensing device for nLight AIR devices and luminaires with
EM emergency options.
RES7EM, RES7PDT, RIOEM See UL924 Sequence of Operation chart on page 3. Not available with 72L, 72LHE, 85L or 85LHE lumen packages. Not available with GZ10 or GZ1 driver.
RRL_ For ordering logic consult: RRL_2013.
SLD Not available with any nLight Interface or Control options.
2BLT Volumetric Recessed Lighting 2'x4'
SDSM Diffuser Option
Non-Configurable BLT Stock/MTO Catalog Description * UPC Lumens Wattage LPW Color Temperature Voltage Pallet Qty
Stock 2BLT4 40L ADP LP835 00190887470789 4000 31.69 126.22 3500K/82 CRI 120-277 28
2BLT4 40L ADP LP840 00190887470765 4063 31.69 128.23 4000K/82CRI 120-277 28
2BLT4 46L ADP LP835 00190887468656 4960 38 130.5 3500K/82 CRI 120-277 28
2BLT4 46L ADP LP840 00190887468649 5039.18 38 132.58 4000K/82CRI 120-277 28
2BLT4 40L ADP EL14L LP835 00190887470925 4000 31.69 126.22 3500K/82 CRI 120-277 28 2BLT4 40L ADP EL14L LP840 00190887470918 4063 31.69 128.23 4000K/82 CRI 120-277 28
2BLT4 46L ADP EL14L LP835 00190887468670 4960 38 130.5 3500K/82 CRI 120-277 28
2BLT4 46L ADP EL14L LP840 00190887468663 5039.18 38 132.58 4000K/82 CRI 120-277 28
*Generic 0-10V Dimming to 10%.
Non-Configurable BLT
MOUNTING DATA
Ceiling Type Appropriate Trim Type
Exposed grid tee (1' and 9/16") G
Concealed grid tee G
Plaster or plasterboard G*
*DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 24-3/4" x 24-3/4" (Tolerance is +1/8", -0").
9/16 Screw Slot15/16 UL924 Sequence of Operation
The below information applies to all nLight AIR devices with an EM option.
• EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds.
• Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts.
• Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing.
Multiple Diffuser Options
Curved Ribbed
ADP
Square Ribbed
SDP
Square Smooth
SDSM ADSM
Curved Smooth
LUGR
Low UGR http://www.lithonia.com https://img.acuitybrands.com/public-assets/catalog/272933/pssd2.pdf?abl_version=04%2f05%2f2019+06:07:28&DOC_Type=SPEC_SHEET https://img.acuitybrands.com/public-assets/catalog/248102/rrl.pdf?abl_version=05%2f18%2f2021+20:31:30&DOC_Type=SPEC_SHEET
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4'
Accessories: Order as separate catalog number.
DGA24 Drywall grid adapter for 2x4 recessed fixture 2X4SMKSHP PAF Surface Mount Troffer Kit Post Paint RK8BDP 2P U Disconnect Plug (BDP), 2 Pole, Package of 1 RK8BDP 3P U Disconnect Plug (BDP), 3 Pole, Package of 1 RK8BDP 2P J10 Disconnect Plug (BDP), 2 Pole, Package of 10 RK8BDP 2P J40 Disconnect Plug (BDP), 2 Pole, Package of 40
Replacement Parts: Order as separate catalog number.
*249P2N 2DBLT48 ADP LENS ASSEMBLY 4 ft. replacement lens *249P2T 2DBLT48 SDP LENS ASSEMBLY 4 ft. replacement lens *249P30 2DBLT48 ADSM LENS ASSEMBLY 4 ft. replacement lens *249P33 2DBLT48 SDSM LENS ASSEMBLY 4 ft. replacement lens *237LT2 2DBLT48 ADPT LENS ASSEMBLY 4 ft. replacement lens *237LT4 2DBLT48 SDPT LENS ASSEMBLY 4 ft. replacement lens *237LT6 2DBLT48 ADSMT LENS ASSEMBLY 4 ft. replacement lens *237LT8 2DBLT48 SDSMT LENS ASSEMBLY 4 ft. replacement lens *237LTA 2DBLT48 ADPT SENSOR LENS ASSEMBLY 4 ft. replacement lens *237M52 2DBLT48 SDPT SENSOR LENS ASSEMBLY 4 ft. replacement lens *237M5A 2DBLT48 ADSMT SENSOR LENS ASSEMBLY 4 ft. replacement lens *237M5L 2DBLT48 SDSMT SENSOR LENS ASSEMBLY 4 ft. replacement lens
Accessories & Replacement Parts
1. Power: I nstall JOT enabled fixtures and controls as instructed.
2. Pair: I nsert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds.
3. Play: O nce paired, each fixture will individually dim down to 10% brightness. All products will be fully functional.
BLT Series
Sensor Switch
WSXA JOT
Sensor Switch JOT Enabled Wireless Solution Designed with contractors in mind, the Sensor Switch JOT enabled wireless solution offers a straightforward approach to the installation and pairing of lighting fixtures and controls. Absolutely no 0-10V control wires and no mobile apps are needed with JOT enabled products, allowing for lightning speed installation right out of the box.
BLT Series with integrated
JOT OCC
Sensors
Sensor Switch
SPODMRA JOT
JOT Wireless
Emergency Battery Pack Options - Field Installable Battery Model Number Wattage Runtime
(Minutes) Lumen Output*
@ 120 Lumens/Watt Other
ILB CP07 2H A 7W 120 840 Storm Shelter/ 2-hour Runtime
ILB CP10 A 10W 90 1200
ILBLP CP10 HE SD A 10W 90 1200 Title 20, Self Diagnostic ILBLP CP15 HE SD A 15W 90 1800 Title 20, Self Diagnostic ILB CP20 HE A 20W 90 2400 Title 20 ILB CP20 HE SD A 20W 90 2400 Title 20, Self Diagnostic All the above are UL Listed products that are certified for field install external/remote to the fixture.
*Minimum delivered lumen output to assist in product selection for increased fixture mounting height.
The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast.
Please contact us at productsupportemergency@acuitybrands.com for any Emergency Battery related questions.
http://www.lithonia.com https://www.iotaengineering.com/products/detail/1009403/ https://www.iotaengineering.com/products/detail/1009409/ https://www.iotaengineering.com/products/detail/1233619/ https://www.iotaengineering.com/products/detail/1233623/ https://www.iotaengineering.com/products/detail/1009434/ https://www.iotaengineering.com/products/detail/1009437/ mailto:productsupportemergency%40acuitybrands.com?subject=
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4' nLight Platform nLight embedded fixtures offer: Customers get:
Manual Dimming Convenience and visual comfort for occupants
Motion Sensing and/or Daylight Harvesting Energy savings and code compliance
Fixture or Group Level Control Ability to configure lighting to the space requirements
Flexibility Ease of fixture moves, adds and changes
Wireless Wall Switch (nLight AIR Only) Ease and flexibility of placement
Astronomical and Time of Day Scheduling Energy savings and building security
Scalable Solution nLight controls to grow with your business
Future-Ready nLight platform to set foundation for future upgrades and capabilities
NH NH NH
BLT Series nLight Wired nPODMA
CAT5e
NH NH NH
BLT Series nLight AIR rPODBA Mobile Device
Simple as 1,2,3
| 1. | Install the nLight® AIR fixtures with embedded smart sensor |
| 2. | Install the wireless battery-powered wall switch |
| 3. | With CLAIRITY+ app, pair the fixtures with the wall switch |
and if desired, customize the sensor settings for the desired outcome
Simple as 1,2,3
| 1. | Install the nLight® Wired fixtures with embedded control |
| 2. | Install the nLight Wired wall switch |
| 3. | Connect the fixtures using standard CAT5e cables and the devices |
will automatically discover each other and work (plug and play) nLight Air Wireless nLight Wired Networking
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4'
Sensor Options
Option Automatic Dimming Photocell
Occupancy Sensing nLight Wired Networking nLight AIR NetworkingPIR PDT
MSD7ADCX X X
MSDPDT7ADCX X X
NES7 X X
NES7ADCX X X X
NESPDT7 X X
NESPDT7ADCX X X X
RES7 X X X
RESPDT7 X X X X
Integrated Sensor with Individual Control The MSD7ADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions and where daylight harvesting may be desired. Suggested applications include, but not limited to, hallways, corridors, storage rooms, and breakrooms or other areas where people are typically moving.
The MSDPDT7ADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and where daylight harvesting is desired. Suggested applications include, but not limited to, open offices, private offices, classrooms, public restrooms, and conference rooms.
Sequence of Operation (nES7 and rES7 and Sensor)
MIN
LIG
HT
LE
VE
L
MAX
7.5 MIN
TIME DELAY
2.5 MIN AT
A 1% LEVEL
LIGHTS OFF LIGHTS ONLIGHTS ON
Room Unoccupied
Occupants Detected In The Space
Sensor Detects Motion
MOTION NO MOTION MOTION
SEQUENCE OF OPERATION
5.5 18
4.6 15
3.7 12
2.7 9
1.8 6
0.9 3 0 m 0 ft
0.9 3
1.8 6
2.7 9
3.7 12
4.6 15
5.5 18
9 FT Mounting
• Recommended for walking motion detection from mounting heights between 8 ft (2.44 m) and 20 ft (6.10 m)
• Initial detection of walking motion along sensor axes at distances of 2x the mounting height up to 15 ft (4.57 m) and
| • | 1.75x up to 20 ft (6.10 m). |
| • | Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m) |
| • | Initial detection will occur earlier when walking across sensor's field of view than when |
walking directly at sensor
Sensor Coverage Pattern Mini 360° Lens
*The presetting on the automatic dimming photocell is 5fc (NES7) and 10fc (RES7).
Sequence of Operation (MSD7 Sensor)
MIN
LIG
HT
LE
VE
L
MAX
17.5 MIN
TIME DELAY
2.5 MIN AT
A 1% LEVEL
LIGHTS OFF LIGHTS ONLIGHTS ON
Room Unoccupied
Occupants Detected In The Space
Sensor Detects Motion
MOTION NO MOTION MOTION
SEQUENCE OF OPERATION
*The presetting on the automatic dimming photocell is 5fc.
nLight AIR Wireless nLight AIR is the ideal solution for retrofit or new construction spaces where adding additional wiring can be labor intensive and nLight AIR is available with or without an integral sensor. The integrated rES7 or rES7PDT smart sensors are part of each luminaire in the nLight AIR network, which can be grouped to control multiple luminaires. The granularity of control with the digital PIR occupancy detection and daylight sensing makes a great solution for any application.
nLight Wired Networking The nES 7 is ideal for small rooms without obstructions or areas with primarily walking motion.
Ideal areas include hallways, corridors, storage rooms, and breakrooms. Additionally, the nES7ADCX includes an integrated photocell, which enables daylight harvesting controls.
For areas like restrooms, private offices, open offices, conference rooms or any space with obstructions, the nES PDT 7 dual technology sensor is recommended. The nES PDT 7 utilizes both PIR (passive infrared) and Microphonics technologies to detect occupancy. Additionally, the nESPDT7ADCX includes an integrated photocell, which enables daylight harvesting controls which is ideal for areas where windows are present.
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4' nLight® Wired Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight.
WallPod stations Model number Occupancy sensors Model number On/Off nPODMA [Color] Small motion 360°, ceiling (PIR / dual tech) nCM 9 RJB / nCM PDT 9 RJB On/Off & raise/lower nPODMA DX [Color] Large motion 360°, ceiling (PIR / dual tech) nCM10 RJB / nCM PDT 10 RJB Graphic touchscreen nPOD TOUCH [Color] Wall switch with raise/lower nWSX PDT LV DX [color] Photocell controls Model number Cat-5 cable (plenum rated) Model number Full range dimming nCM ADCX RJB 10' cable CAT5 10FT J1
30' cable CAT5 30FT J1 nLight® AIR Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/ controls/nlightair.
Wall switches Model number On/Off single pole rPODBA [color] G2 On/Off two pole rPODB A2P [color] G2 On/Off & raise/lower single pole rPODBA DX [color] G2 On/Off & raise/lower two pole rPODBA 2P DX [color] G2
RCMS
Notes 1 RCMS requires low voltage power from either RPP20 DS 24V G2 or PS150.
rCMS1 Example: RCMS PDT 10 AR G2
Series / Detection Power Supply1 Occupancy Detection Lens (Required) Operating Mode Generation
RCMS nLight AIR occupancy and daylight sensor
[blank] Power Supply ordered separately
PS 150 Standard 150 mA Power Supply
[blank] PIR Detection PDT Dual Tech PIR/
Microphonics
10 Large Motion/ Extended Range 360°
9 Small Motion/ Extended Range 360°
6 High Bay 360° Lens
[BLANK] None AR Auxiliary
Relay
G2 Generation 2 compatibility
Controls Accessories
Sensor Switch
WSX
nLight WIRED nPODMA DX nLight AIR rPODBA rPODBA
Winning in Small OffiesWinning in Small Offies
BLT fixtures with integrated rIO devices complement any small office space. Pair them with an rCMS occupancy sensor and the space now has wireless occupancy sensing and dimming capability. For additional configuration options please consult with Tech Support.
BLT with rIOnLight WIRED
NPOD UNITOUCH
http://www.lithonia.com https://nlight.acuitybrands.com/ https://nlight.acuitybrands.com/ https://nlight.acuitybrands.com/ https://www.acuitybrands.com/products/detail/708905/sensor-switch/wsx-series/wall-switch-sensor https://www.acuitybrands.com/products/detail/708905/sensor-switch/wsx-series/wall-switch-sensor https://www.acuitybrands.com/products/detail/982001/nlight/npodma-family/nlightr-wired-wall-switch https://www.acuitybrands.com/products/detail/982001/nlight/npodma-family/nlightr-wired-wall-switch https://www.acuitybrands.com/products/detail/982003/nlight/rpodba-family/nlightr-air-wall-switch https://www.acuitybrands.com/products/detail/982003/nlight/rpodba-family/nlightr-air-wall-switch https://www.acuitybrands.com/products/detail/981468/nlight/nlightr-unitouch/touchscreen-wall-switch https://www.acuitybrands.com/products/detail/981468/nlight/nlightr-unitouch/touchscreen-wall-switch
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4'
Enabled by the embedded nLight control, the BLT actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life. Referred to as lumen management, this feature eliminates the energy waste created by the traditional practice of over-lighting.
Constant Lumen Management
PHOTOMETRICS
2BLT4 40L ADP LP835, 4000 delivered lumens, test no. ISF36900P109, tested in accordance to IESNA LM-79
2BLT4 48L ADP LP835, 4960 delivered lumens, test no. ISF 36900P117, tested in accordance to IESNA LM-79
0° 20°
40°
60°
80°
90°
0°0°0° 90°
180°
Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10%
R C
R
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 120°
90° - 130°
90° - 150°
90° - 180°
0° - 180°
25.6
41.7
74.0
100.0
0.0
0.0
0.0
0.0
100.0
25.6
41.7
74.0
100.0
0.0
0.0
0.0
0.0
100.0
CP Summary
0° 90
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
0° 20°
40°
60°
80°
90°
0°0°0° 90°
180°
Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10%
R C
R
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 120°
90° - 130°
90° - 150°
90° - 180°
0° - 180°
25.6
41.7
74.0
100.0
0.0
0.0
0.0
0.0
100.0
25.6
41.7
74.0
100.0
0.0
0.0
0.0
0.0
100.0
CP Summary
0° 90
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
0 10 20 30 40 50
THOUSAND OPERATING HOURS
0 10 20 30 40 50
THOUSAND OPERATING HOURS
POWER INPUT
LIGHT
OUTPUT
100%
80%
100%
80%
34W
27W
34W
27W
LI
G
H T
O U
TP
U
T
LI
G
H T
O U
TP
U
T
PO
W
ER
IN
PU
ER
IN
PU
T
Without Lumen Management Energy is wasted and light level is inconsistent.
POWER
INPUT
LIGHT OUTPUT
With Lumen Management Energy is saved and light level remains consistent.
Wasted Energy
Saved Energy
0 10 20 30 40 50
THOUSAND OPERATING HOURS
0 10 20 30 40 50
THOUSAND OPERATING HOURS
POWER INPUT
LIGHT
OUTPUT
100%
80%
100%
80%
34W
27W
34W
27W
LI
G
H T
O U
TP
U
T
LI
G
H T
O U
TP
U
ER
IN
PU
ER
IN
PU
T
Without Lumen Management Energy is wasted and light level is inconsistent.
POWER
INPUT
LIGHT OUTPUT
With Lumen Management Energy is saved and light level remains consistent.
Wasted Energy
Saved Energy
BLT-2X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/29/22
2BLT Volumetric Recessed Lighting 2'x4'
HE Performance Data Model Number Lumens LPW Watts DLC Listing DLC ID 2BLT4 30LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 3107 135.17 22.98 Premium P7KEICW5 2BLT4 30LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 3156.6 137.33 22.98 Premium PDOM06BH 2BLT4 30LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 3065.57 133.37 22.98 Premium P7PZAJDZ 2BLT4 30LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 3114.51 135.5 22.98 Premium P2N23EBP 2BLT4 40LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 4085 138.56 29.48 Premium P67P6S5Y 2BLT4 40LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 4150.21 140.77 29.48 Premium P95UQD66 2BLT4 40LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 4030.53 136.71 29.48 Premium PC15DQEC 2BLT4 40LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 4094.88 138.89 29.48 Premium PGRCSJ2T 2BLT4 48LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 4770 138.16 34.52 Premium PXBJBGN8 2BLT4 48LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 4846.15 140.37 34.52 Premium P5PQ5RRX 2BLT4 48LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 4706.4 136.32 34.52 Premium P2NK2H33 2BLT4 48LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 4781.53 138.5 34.52 Premium PK8C1321 2BLT4 60LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 5894 135.12 43.61 Premium PQZN176R 2BLT4 60LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 5988.09 137.28 43.61 Premium PG5CYJUC 2BLT4 60LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 5815.41 133.32 43.61 Premium PZ72TAWM 2BLT4 60LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 5908.25 135.45 43.61 Premium PRC4W72B 2BLT4 72LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 7149 135.94 52.58 Premium PUB38GEQ 2BLT4 72LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 7263.13 138.11 52.58 Premium P7GDHZTN 2BLT4 72LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 7053.68 134.12 52.58 Premium P5CC2VKV 2BLT4 72LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 7166.29 136.26 52.58 Premium P6P1BKDM 2BLT4 85LHE ADP EZ1 (GZ1, GZ10) LP835 [All Options] 8158 128.96 63.25 Premium PRTW6BXW 2BLT4 85LHE ADP EZ1 (GZ1, GZ10) LP840 [All Options] 8288.24 131.02 63.25 Premium P6H1V2D6 2BLT4 85LHE ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 8049.22 127.24 63.25 Premium P1VG5TA3 2BLT4 85LHE ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 8177.73 129.27 63.25 Premium PN5BKJ6E
DLC information is subject to change, for the most up-to-date information please refer to www.dlc.org. Above listings do not cover 347v or SLD.
How to Estimate Delivered Lumens in Emergency Mode Use the formula below to estimate the delivered lumens in emergency mode Delivered Lumens = 1.25 x P x LPW P = Ouput power of emergency driver. P = 10W for E10WLCP option.
LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet. LPW = Lumen per watt rating of the luminaire. LPW information available in Performance Data section.
Performance Data Model Number Lumens LPW Watts DLC Listing DLC ID 2BLT4 30L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 2962 127.31 23.26 Premium PWJDEMHS 2BLT4 30L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 3009.28 129.34 23.26 Premium P18J5GLD 2BLT4 30L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 2969.16 127.62 23.26 Premium P3HB2XSG 2BLT4 40L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 4000 126.22 31.69 Premium PDWKYXFD 2BLT4 40L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 4063.86 128.23 31.69 Premium PEYXAZWD 2BLT4 40L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 3946.66 124.53 31.69 Premium PS63CPK6 2BLT4 40L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 4009.67 126.52 31.69 Premium PK79UR9W 2BLT4 48L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 4960 130.5 38 Premium PJ9CK6C1 2BLT4 48L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 5039.18 132.58 38 Premium P9W2R5AK 2BLT4 48L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 4893.86 128.76 38 Premium PPFKZU3U 2BLT4 48L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 4971.99 130.82 38 Premium PC8HMCH9 2BLT4 60L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 6016 126.39 47.59 Premium PSJ6QERM 2BLT4 60L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 6112.04 128.4 47.59 Premium PVXQXPUV 2BLT4 60L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 5935.78 124.7 47.59 Premium PHT84BW4 2BLT4 60L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 6030.55 126.69 47.59 Premium PXV55BC8 2BLT4 72L ADP EZ1 (GZ10) LP840 [All Options] 7360.66 125.3 58.74 Premium PSCZ22CB 2BLT4 72L ADP GZ1 LP835 [All Options] 7245 119.07 60.84 standard PISHTCTS 2BLT4 72L ADP GZ1 LP840 [All Options] 7360.66 120.97 60.84 standard PBERALG7 2BLT4 72L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 7148.4 117.48 60.84 standard PDQS3CYK 2BLT4 72L ADPT EZ1 (GZ10) LP840 [All Options] 7262.52 123.63 58.74 Premium P2KKMMVN 2BLT4 72L ADPT GZ1 LP840 [All Options] 7262.52 119.36 60.84 standard P10DUPC0 2BLT4 85L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 8567 116.43 73.58 standard PYD2GO6V 2BLT4 85L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 8703.77 118.28 73.58 standard P8Z4IV4X 2BLT4 85L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 8452.77 114.87 73.58 standard PTZEW3QM 2BLT4 85L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 8587.72 116.71 73.58 standard P01DMEK9 2BLT4 100L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 9837 103.14 95.36 standard PGDES20R 2BLT4 100L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 9994.04 104.79 95.36 standard P007CHGX 2BLT4 100L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 9705.84 101.77 95.36 standard PSZUQY7M 2BLT4 100L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 9860.79 103.39 95.36 standard P6V6X6HY 2BLT4 120L ADP EZ1 (GZ1, GZ10) LP835 [All Options] 11709 118.18 99.07 standard PGM4Y7DP 2BLT4 120L ADP EZ1 (GZ1, GZ10) LP840 [All Options] 11895.9 120.07 99.07 standard P0ODDCG2 2BLT4 120L ADPT EZ1 (GZ1, GZ10) LP835 [All Options] 11552.9 116.61 99.07 standard PXM0FS09 2BLT4 120L ADPT EZ1 (GZ1, GZ10) LP840 [All Options] 11737.3 118.47 99.07 standard PJ4GEBZM
DLC information is subject to change, for the most up-to-date information please refer to www.dlc.org. Above listings do not cover 347v or SLD.
http://www.lithonia.com
| Catalog Number: |
| Notes: |
| Type: |
| Air Function: |
| Lumens: |
| Diffuser: |
| Voltage: |
| Driver: |
| Color Temp: |
| Controls 3: |
| Occupancy Controls 3: |
| Options 3: |
| Occupancy Controls 4: |
| Air Function 2: |
| Accessories 2: |
| Replacement Parts 2: |
| nLight AIR Control Accessories 4: |
| nLight AIR Control Accessories 5: |
| nLight AIR Control Accessories 6: |
| nLight AIR Control Accessories 7: |
| nLight AIR Control Accessories 8: |
| nLight AIR Control Accessories 9: |
| nLight Wired Control Accessories 3: |
| nLight AIR Control Accessories 3: |
File details come from the government source that posted it. Updated .