This is a technical specification detail document for concrete parking bumpers (wheelstops) related to the McIntosh Park Wetland Construction project, an Invitation for Bid (IFB 26-048UO-IFB) issued by the City of Plant City, Florida. The specification establishes requirements for precast concrete parking bumpers that are standard products manufactured for parking space applications. The bumpers must be constructed to develop a twenty-eight day concrete compressive strength of 3,000 PSI minimum and include two number 4 reinforcing rods running the full length of the bumper. Installation requires centering bumpers on each parking space and securing them to the substrate with two 3/4-inch reinforcing rods driven through corresponding holes to a depth of eighteen inches, with rod tops flush to the bumper surface. The project involves 363 acres of wetland excavation and restoration, with bid due September 24, 2026 at 2:00 p.m., a pre-proposal meeting scheduled for September 10, 2026 at 10:30 a.m., and questions due September 14, 2026. Substantial completion is required within 540 calendar days of Notice to Proceed, with final completion within 30 days thereafter.

The project is partially funded through the State of Florida Department of Environmental Protection Grant Agreement No. LPA0038, with all work required to comply with grant terms and conditions. The City of Plant City offers local preference of up to one percent discount or $2,500 whichever is less to qualifying bidders. The contract is fixed-price with 5 percent retainage, and the City awards to the lowest responsive and responsible bidder. Contractors must maintain General Contractor and Underground Utility and Excavation Contractor licenses, self-perform a minimum of 30 percent of total project cost, and provide qualifying experience including three projects involving excavation of 300,000 cubic yards or greater within Florida and three projects involving wastewater or reuse collection systems. Insurance requirements include Workers' Compensation, Commercial General Liability of $500,000 per occurrence/$1,000,000 aggregate, Commercial Automobile Liability of $500,000, and Railroad Protective Liability of $5,000,000 per occurrence/$10,000,000 aggregate. Liquidated damages range from $1,015 to $10,203 per day, and bids must remain valid for 90 days from submittal.

View the file

Other files

File Type Posted
McIntosh_Park_Wetland_Construction_(Addendum_#10_Revision).pdf PDF
M&P_ALLOWANCE_Line_Items.docx DOCX document
McIntosh_Park_Wetland_Construction_(Addendum_#8_Revision).pdf PDF
PCFR_Open_Burn_Permit.docx DOCX document
Question#78_ReferenceDetail.docx DOCX document
Question_51_UpdatedTable.pdf PDF
Question_52_UpdatedTable.pdf PDF
CSX_Permit_CSX022389_-_dated_Sept_13,_2023.pdf PDF
Environmental_Resource_Permit_no.43044733.002_-_May_24,_2024.pdf PDF
Environmental_Resource_Permit_no._43044733.003_-_December_27,_2025.pdf PDF
Hillsborough_County_EPC_review_no.79173_-_February_12,_2025.pdf PDF
Hillsborough_County_EPC_-_review_no.69805_-September_30,_2025.pdf PDF
Army_Corps_permit_SAJ-2024-04226(SP-CM)_-_December_19_2025.pdf PDF
MCINTOSH_PARK_INTEGRATED_WATER_MANAGMENT_PHASE_II.dst —
MCINTOSH_PARK_INTEGRATED_WATER_MANAGEMENT_PLAN_60%_WETLAND_DESIGN.txt TXT text file
x-survey_base.dwg DWG drawing
additonal_Lidar_contours_Exp.dwg DWG drawing
DCS.ctb —
silt_fence_and_turbidity_barriers_detailsce8ff31f.png PNG image
silt_fence_and_turbidity_barriers_detailsb2baa412.png PNG image
silt_fence_and_turbidity_barriers_details3702a52e.png PNG image
2013RevisedDesignerManual_-_Part2_2152afa2d9.png PNG image
dewberry-master_template_22x34.dwt —
PR22579_McIntosh_Preserve_Evaluation_Update.pdf PDF
FDOT_DITCH_BOTTOM_INLET.pdf PDF
E-58-39.pdf PDF
E-58-39_e-SHEET.pdf PDF
HIL2020_468223.sid SID file
WETLAND_IMPACT_MAP.dwg DWG drawing
WETLAND_DELINEATION_MAP.dwg DWG drawing
SURVEY_CONTROL_SHEET.DWG DWG drawing
STANDARD_DETAILS.dwg DWG drawing
PLANTING_PLAN.dwg DWG drawing
OVERALL_SITE_PLAN.dwg DWG drawing
KEY_SHEET.dwg DWG drawing
GRADING_AND_DRAINAGE_PLANS.dwg DWG drawing
GENERAL_NOTES_AND_LEGEND.dwg DWG drawing
EXISTING_CONDITIONS_PLAN.dwg DWG drawing
COVER_SHEET.dwg DWG drawing
wetland-solutions-color.png PNG image
Plant_City_Logo.jpg JPG image
OP2017_NC_468524_24.sid SID file
OP2017_NC_468523_24.sid SID file
OP2017_NC_468224_24.sid SID file
OP2017_NC_468223_24.sid SID file
McIntosh_Preserve_Logo.jpg JPG image
HIL2020_468524.sid SID file
HIL2020_468523.sid SID file
HIL2020_468224.sid SID file
DewberryLogo_RGB.jpg JPG image
Show 40 more

Latest 50 of 131 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPICAL CONCRETE WHEELSTOP DETAIL

AutoCAD SHX Text

.75" DIA. HOLE

AutoCAD SHX Text 6'

AutoCAD SHX Text 6'

AutoCAD SHX Text 5.625"

AutoCAD SHX Text 5.625"

AutoCAD SHX Text

TYP

AutoCAD SHX Text

6' (9' @ H.C. SPACES)

AutoCAD SHX Text 18"

AutoCAD SHX Text 5.625"

AutoCAD SHX Text PARKING BUMPER: (PRECAST CONCRETE) SIZE AND SHAPE: BUMPERS SHALL BE A STANDARD PRODUCT NORMALLY BUMPERS SHALL BE A STANDARD PRODUCT NORMALLY MANUFACTURED FOR THE PURPOSE. SIZE SHALL BE AS INDICATED ON PARKING BUMPER DETAIL. CONSTRUCTION: CONCRETE DEVELOP A TWENTY-EIGHT (28) DAY CONCRETE DEVELOP A TWENTY-EIGHT (28) DAY COMPRESSIVE STRENGTH OF 3000 PSI MINIMUM. PROVIDE TWO (2) NUMBER 4 REINFORCING RODS RUNNING THE LENGTH OF THE BUMPER LOG. INSTALLATION: LOCATE BUMPERS AS INDICATED AND CENTERED ON EACH LOCATE BUMPERS AS INDICATED AND CENTERED ON EACH PARKING SPACE. SECURE BUMPERS TO SUBSTRATE WITH TWO 3/4 INCH REINFORCING RODS DRIVEN THROUGH THE 3/4 INCH DIAMETER HOLES TO A DEPTH OF EIGHTEEN INCHES (18") INTO THE SUBSTRATE. REINFORCING RODS SHALL BE DRIVEN SO THAT THE TOPS OF THE RODS ARE FLUSH WITH THE TOP OF THE BUMPER.