This file is a technical drawing for the Portland International Airport Fire Protection Replacements project in Oregon. The document is a floor plan sheet (F1.02) dated November 2026, prepared by registered professional engineer Anthony C. Lewellen and showing the Terminal South Floor Plans for fire protection systems. The drawing illustrates two zones requiring fire protection replacements: Zone T-S-UT-2-PA and Zone T-N-UT-3-PA, both located in utility tunnels beneath the terminal. The project involves removing existing fire protection pipes, sprinklers, and accessories from both zones and replacing them with NFPA 13-compliant systems, along with replacing the pre-action cabinet in Zone T-S-UT-2-PA with either a double interlocked stacked valve assembly with compressor or a new NFPA 13-compliant double interlocked pre-action cabinet. The drawing also indicates requirements to provide protection for electrical distribution routed through the tunnel, with the tunnel height approximately 5 feet 2 inches.
The drawing provides scaled floor plans with dimensional details and cross-references to related sheets and details. No pricing information, set-asides, incumbent contractors, funding sources, or other commercial terms are included in this technical document, which serves as a design reference for contractors bidding on or executing the fire protection replacement work at Portland International Airport.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
405 SF
PM
B
ELEV M
AC
H
P0145
248 SF
PM
B
ELEV M
AC
H
P0144
BABB
N
KEY PLAN
SCALE: N.T.S.
10/26/2026
C
AN
Y O
U S
EE
T
H E
AI
R
PL
AN
ES
T H
E
AD
JA
C
EN
T
SA
M
PL
ES
S H
O W
T H
R
EE
D
IF
FE
R
EN
T
LE
VE
LS
O
F
SH
AD
IN
G
SE
TT
IN
G
S
FO
R V
IE
W
IN
G
A N
D P
R
IN
TI
N
G D
R
AW
IN
G
C O
N
TE
N T
AR
E
O
PT
IM
IZ
ED
W
H
EN
AL
L
TH
R
EE
P
LA
N
ES
A
R E
VI
SI
BL
E.
T H
IS
G
U
ID
AN
C
E
IS
P R
O
VI
D
ED
F O
R R
EF
ER
EN
C
E O
N
LY
PRINTED:
lig ht da rk gr ay bl ac k
DESIGN NUMBER PROJECT NUMBER
2"
G R
AP
H
IC
S
C
AL
E
- F
O R
R
EF
ER
EN
C E
O N
LY
gr ay
2:55:27 PM CIMINS r:\aviation\pdx\2026\0002 - terminal utility tunnel sprinkler replacements\sheets - fire\terminal tunnels.dwg
DISC. SHT. NO.
DRAWING SCALE IS RED8CED �0� WHEN SHEET SIZE IS 11" x 17"
DESIGN BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
SUBMITTED BY
DRAWING NO.
TYPE:
1/
4" 1/
2" 1"
1/
4" 1/
2" 1"
DATE BY REVISION APPDATE BY REVISION APP ##
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
PORTLAND INTERNATIONAL AIRPORT
FIRE PROTECTION REPLACEMENTS
TERMINAL SOUTH FLOOR PLANS - FIRE PROTECTION
TONY LEWELLEN
T. LEWELLEN
S. CIMINO
T. LEWELLEN
NOVEMBER 2026
6 CD
PDX 2026-2 F1.022024D035 103022
RE
GIS
TERED PROFESSIONAL
ANTHONY C. LEWELLEN
DECEMBER 0 9 , 20 13
EXP: 12/31/2026
OREGON
80671
ENGINEER
KEY NOTES :
1. REMOVE EXISTING FIRE PROTECTION PIPE,
SPRINKLERS AND ACCESSORIES ASSOCIATED
WITH ZONE T-S-UT-2-PA AND REPLACE WITH
NFPA 13 COMPLIANT SYSTEM.
2. REMOVE EXISTING FIRE PROTECTION PIPE,
SPRINKLERS AND ACCESSORIES ASSOCIATED
WITH ZONE T-N-UT-3-PA AND REPLACE WITH
NFPA 13 COMPLIANT SYSTEM.
3. REMOVE AND REPLACE PRE-ACTION CABINET
(T-S-UT-2-PA) WITH NFPA 13 COMPLIANT
DOUBLE INTERLOCKED STACKED VALVE
ASSEMBLY AND COMPRESSOR OR NEW NFPA
13 COMPLIANT DOUBLE INTERLOCKED
PRE-ACTION CABINET.
4. PROVIDE PROTECTION FOR ELECTRICAL
DISTRIBUTION ROUTED THROUGH THE
TUNNEL.
TUNNEL HEIGHT
APPROX. 5'
2 T-N-UT-3-PA
1T-S-UT-2-PA UP TO ELECTRICAL
ROOM T1192
ON DEPLANING LEVEL
F1.02
F8.02
PROJECT AREA
SCALE:
SOUTH TUNNEL FIRE PROTECTION PLAN
1/16" = 1'-0"1
SCALE:
DEPLANING FIRE PROTECTION PLAN
1-1/2" = 1'-0"2
N
T1TF33
(T1192)
ELECTRICAL
T1TF38
(T1194)
ELEC/MECH
M
AT
C H
L
IN
E
SE
E D
ET
AI
L 1, S H
EE
T
F1 .0
C
B
A
6 7 8
F8.02
F8.013
FROM UTILITY
TUNNEL
F1.02
BA AG AF AE AC A B C D E E' F G G' H H'AD
23.0'27.0'
.5
.5
.3
31.6' 38.0' 52.0' 8.0' 25.0' 30.0' 30.0' 30.0' 14.0' 15.2' 30.0' 9.8' 21.0' 23.0'
SCALE: IN FEET
0' 0'-8" 1'-4" 2'-8" 4'
N
SCALE: IN FEET
0' 8' 16' 32' 48'
| 2026-11-10T12:09:53-0800 | |
| Tony Lewellen |