PDX 2026-2 (4) F0.01.pdf

PDF 223 KB Posted

Attached to
Portland International Airport Fire Protection Replacements
Solicitation number
148221
Issued by
Multnomah County, Oregon

About this file

This file is a symbols, legends, and abbreviations reference sheet for the Portland International Airport Fire Protection Replacements project in Oregon. The document serves as a design standard for fire protection systems and provides comprehensive guidance on the graphical symbols, terminology, and abbreviations used throughout the project drawings. The sheet includes standard fire protection abbreviations, piping connection symbols, valve types, sprinkler head designations, and zone identification boxes. A water flow test conducted on May 20, 2020, at hydrant #007 established the basis of design with static pressure of 92 PSI, residual pressure of 78 PSI, and flow of 893 GPM. The design incorporates a 10 percent PSI cushion above specified pressure requirements and adheres to NFPA 13 standards, airport insurance requirements, and local codes for fire sprinkler system location, sizing, and installation.

The document does not contain pricing information, contract terms, set-asides, funding sources, or other commercial terms. As a technical reference sheet dated November 2026, it is designed to ensure consistency and clarity across all project drawings related to the terminal utility tunnel sprinkler replacements at Portland International Airport. The sheet explicitly notes that it is a standard legend document, and some symbols included may not appear on all project drawings.

View the file

Other files

File Type Posted
PDX 2026-2 (3) GI1.03.pdf PDF
PDX 2026-2 (11) F1.07.pdf PDF
PDX 2026-2 (13) F8.02.pdf PDF
PDX 2026-2 (10) F1.06.pdf PDF
PDX 2026-2 (2) GI1.02.pdf PDF
Getting the most out of your Port of Portland Vendor Profile.docx DOCX document
PDX 2026-2 (6) F1.02.pdf PDF
PDX 2026-2 (8) F1.04.pdf PDF
2026-14928 Project Manual.pdf PDF
PDX 2026-2 (9) F1.05.pdf PDF
PDX 2026-2 (7) F1.03.pdf PDF
Substitution Request Form.pdf PDF
PDX 2026-2 (12) F8.01.pdf PDF
PDX 2026-2 (1) GI1.01.pdf PDF
PDX 2026-2 (0) Bid COVER.pdf PDF
PDX 2026-2 (5) F1.01.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10/26/2026

C

AN

Y O

U S

EE

T

H E

AI

R

PL

AN

ES

T H

E

AD

JA

C

EN

T

SA

M

PL

ES

S H

O W

T H

R

EE

D

IF

FE

R

EN

T

LE

VE

LS

O

F

SH

AD

IN

G

SE

TT

IN

G

S

FO

R V

IE

W

IN

G

A N

D P

R

IN

TI

N

G D

R

AW

IN

G

C O

N

TE

N T

AR

E

O

PT

IM

IZ

ED

W

H

EN

AL

L

TH

R

EE

P

LA

N

ES

A

R E

VI

SI

BL

E.

T H

IS

G

U

ID

AN

C

E

IS

P R

O

VI

D

ED

F O

R R

EF

ER

EN

C

E O

N

LY

PRINTED:

lig ht da rk gr ay bl ac k

DESIGN NUMBER PROJECT NUMBER

2"

G R

AP

H

IC

S

C

AL

E

- F

O R

R

EF

ER

EN

C E

O N

LY

gr ay

2:41:16 PM CIMINS r:\aviation\pdx\2026\0002 - terminal utility tunnel sprinkler replacements\sheets - fire\symbols-legend-abbrevs.dwg

DISC. SHT. NO.

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"

DESIGN BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

SUBMITTED BY

DRAWING NO.

TYPE:

1/

4" 1/

2" 1"

1/

4" 1/

2" 1"

DATE BY REVISION APPDATE BY REVISION APP ##

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

PORTLAND INTERNATIONAL AIRPORT

FIRE PROTECTION REPLACEMENTS

SYMBOLS, LEGENDS AND ABBREVIATIONS - FIRE PROTECTION

TONY LEWELLEN

T. LEWELLEN

S. CIMINO

T. LEWELLEN

NOVEMBER 2026

4 CD

PDX 2026-2 F0.012024D035 103022

RE

*,6

7ERED 3R2)E66,21$/

$17+21< C� /E:E//E1

DECE0%ER 0 � � �0 ��

E;3� �������0��

2RE*21

�0���

E1*,1EER

WITHOUT

WITH

WATER PRESSURE DROP

WATER GAUGE

WIDTH

VERTICAL

VELOCITY

TYPICAL

TOTAL STATIC PRESSURE

TEMPERATURE

STRUCTUR(E)(AL)

STEEL

STAINLESS STEEL

SQUARE INCH(ES)

SQUARE FOOT(FEET)

SQUARE

SIMULAR

SENSIBLE

SECTION

STANDARD CUBIC FEET PER MINUTE

SWAY BRACE

REVOLUTIONS PER MINUTE

ASSEMBLY

REDUCED PRESSURE BACKFLOW

RISER NIPPLE

ROOM MANIFOLD

REVISION

PRESSURE SWITCH

PHASE

OUTSIDE DIAMETER

ON CENTER DISTANCE

NOT TO SCALE

NORMALLY OPEN

NOT IN CONTRACT

NORMALLY CLOSED

MOUNTED

MISCELLANEOUS

MINIMUM

MANUFACTURER

MECHANICAL

THOUSAND BTU PER HOUR

MAXIMUM

LINEAR FEET

POUND

LENGTH

KILOWATT HOUR

KILOWATT

ISOLAT(OR)(ION)

INSULATION

INCH(ES)

HANGER

HORSEPOWER

HORIZONTAL

GATE VALVE

GALLONS PER MINUTE

GALLONS PER HOUR

GLYCOL

GALVANIZED

GALLON

GAGE/GAUGE

GRADE

FUTURE

FLOW SWITCH

FEET PER SECOND

FEET PER MINUTE

FLEXIBLE

FIGURE

FIRE DEPARTMENT CONNECTION

DEGREES FAHRENHEIT

EXPANSION

EXISTING

EQUIPMENT

EQUAL

ENGINEER

ELEVATION

ELECTRIC(AL)

EXTENDED COVRAGE

DRAWING

DOWN

DROP NIPPLE

DUCTILE IRON PIPE

VALVE ASSEMBLY

DOUBLE DETECTOR CHECK

CENTERLINE

CONTINUE(ED)(UATION)

CONNECT(ION)

CONCRETE

BUTTERFLY VALVE

BASEMENT

BUILDING

BOTTOM OF DECK

BOTTOM OF BEAM

AUTOMATIC

ARCHITECT(URAL)

APPROXIMATELY

ALTERNATIVE

ABOVE FINISHED FLOOR

ABANDON IN PLACE

W/O W/

WPD

WG

W

VERT

VEL

TYP

TSP

TEMP

STRUCT

STL

SS

SQ IN

SF

SQ

SIM

SENS

SECT

SCFM

SB

RPM

RPBA

RN

RM

REV

PS

PH

OD

OC

NOT TO SCALE

NO

NIC

NC

MTD

MISC

MIN

MFR

MECH

MBH

MAX

LF

LB

L

KWH

KW

ISOL

INSUL

IN

HR

HP

HORIZ

GV

GPM

GPH

GLY

GALV

GAL

GA

G

FUT

FS

FPS

FPM

FLEX

FIG

FDC

EXP

EXIST

EQUIP

EQ

ENGR

ELEV

ELEC

EC

DWG

DN

DN

DIP

DCVA

CL

CONT

CONN

CONC

BV

BSMT

BLDG

BOD

BOB

AUTO

ARCH

APPROX

ALT

AFF

(A)

STANDARD FIRE PROTECTION ABBREVIATIONS:

HORIZONTAL SIDE WALLHSW

AUTOMATIC SPRINKLERAS

BOTTOM OF PIPEBOP

BOTTOM OF RISERBOR

CHECK VALVECV

F

FLOOR FLANGE

FINISHED FLOOR

FFL

FF

FIRE HOSE STATION

FIRE HOSE CABINET

FHS

FHC

FEET/FOOTFT

HEIGHTH

INSIDE (DIAMETER/DIMENSION)

HOSE VALVE

ID

HV

INVERT ELEVATIONIE

OPEN BAR JOISTOBJ

OUTSIDE YOKE & SCREWOS & Y

POST INDICATOR VALVEPIV

POUNDS PER SQUARE INCH

PRESSURE REDUCING VALVE

POLYPROPYLENE

PSI

PRV

PP

SPECIFICATION

STATIC PRESSURE

SHUT OFF VALVE

SPEC

SP

SOV

STANDARD SPRAY UPRIGHTSSU

STANDARD SPRAY PENDENTSSP

TAMPER SWITCHTS

SYMBOLS:

RELOCATE EXISTING

REMOVE EXISTINGCONNECT TO EXISTING

CAP EXISTING / CAP FOR FUTURE

NOTEEXISTING TO REMAIN

R

E

XC

K

A ACCESS PANEL

BELOW GRADE / FLOORB

CALL OUT SYMBOLS

DESIGN CUSHION: PROVIDE AN EXCESS OF 10% PSI ADDITIONAL PRESSURE REQUIREMENTS

INCORPORATED INTO THE DESIGN OVER SPECIFIED PRESSURE REQUIREMENTS.

REFER TO DRAWINGS FOR ZONE TYPES, CALLOUTS AND ADDITIONAL SCOPE ITEMS.

USE NFPA 13 FOR THE LOCATION, SIZING & INSTALLATION OF PIPING & SPRINKLER SYSTEMS

DESIGN TO MEET THE AIRPORT, INSURANCE REQUIREMENTS AND LOCAL CODES.

FIRE PROTECTION DESIGN CRITERIA:

FIRE PROTECTION SPRINKLER DESIGN CRITERIA:

PROVIDE THE FOLLOWING HAZARD CLASSIFICATIONS PER NFPA 13 AND AIRPORT STANDARDS.

SEE THE SPECIFICATIONS SECTION 212000 FOR DENSITIES, REMOTE AREAS, AND SPRINKLER

COVERAGES FOR THE LISTED OCCUPANCIES.

WATER SERVICE PRESSURE BASIS OF DESIGN:

PRESSURE USED TO DEVELOP THE FIRE SPRINKLER SYSTEM DESIGN INFORMATION INCLUDED

HEREIN. THE CONTRACTOR SHALL BE REQUIRED TO OBTAIN CURRENT FLOW TEST

INFORMATION PRIOR TO STARTING THEIR DESIGN OF THE FIRE SPRINKLER SYSTEM.

WATER FLOW INFORMATION, HYDRANT #007 (05/20/2020): STATIC: 92 PSI; RESIDUAL; 78 PSI;

FLOW: 893 GPM.

MC

MECHANICAL COUPLING

BALL JOINT

FLEXIBLE CONNECTION

TEE DOWN

TEE UP

ELBOW DOWN

ELBOW UP

RISER

PLUG OR BLIND FLANGE

CAP

FLANGED CONNECTION

UNION

JOINT OR COUPLING POINT

CROSS

TEE

ELBOW (45°)

ELBOW (90°)

ANCHOR

REDUCER

PIPE SLEEVE

DIRECTION OF SLOPE

DIRECTION OF FLOW

HORIZONTAL TEE

PIPING CONNECTIONS

HEAT TRACE

MISC. FITTINGS & SYMBOLS:

DCVA DOUBLE CHECK VALVE ASSEMBLY

GROUND HYDRANTGHG

SHUT-OFF VALVE

GLOBE VALVE

SHUT-OFF VALVE W/ TAMPER SWITCH

TRIPLE DUTY VALVE

CHECK VALVE

2-WAY CONTROL VALVE

3-WAY CONTROL VALVE

PRESSURE REDUCING VALVE

BALANCING VALVE

FLOW CONTROL VALVE

SOLENOID VALVE

RELIEF VALVE

AIR VENT (MANUAL/AUTOMATIC)

STRAINER

STRAINER W/ BLOWDOWN

DRAIN VALVE

WALL HYDRANT

STEAM TRAP

PRESSURE GAUGE

PRESSURE/TEMPERATURE TEST PLUG

THERMOMETER

FLOW SWITCH

TEMPERATURE TRANSMITTER

SHOCK ARRESTOR

VACUUM BREAKER

WATER FLOW METER

REDUCED PRESSURE BACKFLOW ASSEMBLY

DOUBLE CHECK DETECTOR ASSEMBLY

BACKWATER VALVE

UNDERGROUND GATE VALVE W/BOX

UNDERGROUND GATE W/POST INDICATOR

OUTSIDE SCREW & YOKE

Y PATTERN BOILER BLOWDOWN VALVE

NON-RETURN STOP VALVE

QUICK OPENING BOILER BLOWDOWN VALVE

DV

AAVMAV

S

FC

S

HOSE BIBBHB

WH

F

T

(SIZE)S

V

WFM

RPBA

DCDA

BWV

UG

PIV

F&T/IB

GENERAL NOTE:

THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY

APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.

MISC. VALVES & COCKS:

FULL ZONE IDENTIFICATION

BUILDING

LOCATION

FLOOR/LEVEL

ZONE NUMBER

TYPE OF SYSTEM

EXTENSION - TERMINAL - SOUTH EAST - FLOOR 1 - ZONE 1 - WET

ABBREVIATION ZONE IDENTIFICATION

EX-T-SE-1-2-W

BUILDINGS LOCATION FLOOR/LEVEL TYPE OF SYSTEMS

A - CONCOURSE 'A'

B - CONCOURSE 'B'

C - CONCOURSE 'C'

D - CONCOURSE 'D'

E - CONCOURSE 'E'

EX - EXTENSION

T - TERMINAL

A - ALL

C - CENTERAL

N - NORTH

E - EAST

S - SOUTH

W - WEST

UT - TUNNEL

1 - DEPLANING

2 - ENPLANING

3 - MEZZANINE

4 - PENTHOUSE

W - WET

D - DRY

O - DELUGE

PA - PREACTION

SP - STANDPIPE

FIRE SPRINKLER ZONE BOUNDRY

IDENTIFICATION BOXES

PIPE ZONE IDENTIFICATION BOXES

GENERAL NOTE:

CW - CONC. WALKWAY

ZONE NUMBER

1 - ZONE 1

2 - ZONE 2

3 - ZONE 3

4 - ZONE 4

5 - ZONE 5

CA - CLEAN AGENT

FP

PENDANT SPRINKLER HEAD

UPRIGHT SPRINKLER HEAD

STANDPIPE OUTLET

STANDPIPE ROOF CONNECTION

FIRE DEPARTMENT CONNECTION

FIRE SPRINKLER

FIRE PROTECTION

DRY PIPE SPRINKLER

FP

SPR

DP

PA PRE-ACTION SYSTEM

DRY STANDPIPE

WET STANDPIPEWSP

DSP

SIDEWALL SPRINKLER HEAD

SUPERVISED SHUT-OFF VALVE

DRY PIPE VALVE ASSEMBLY

FLOW SWITCH

DPV

PRE-ACTION VALVE ASSEMBLYPAV

S

SO

SRC

FDC

F

COMBINATION STANDPIPECSP

FIRE PROTECTION SYMBOLS:

AREA OF WORK:

AREA WITHIN THIS LINE IDENTIFIES SCOPE

OF WORK PER NOTE

DEMOLITION LEGEND:

REMOVE EXISTING PIPE

REMOVE EXISTING SPRINKLER

NEW AND EXISTING WORK:

EXISTING PIPE

EXISTING SPRINKLER

NEW PIPE

NEW SPRINKLER

B-SE-1-1-W

CONCOURSE OR TERMINAL

LEVEL SPRINKLER ZONE -

TYPE

2026-11-10T12:07:33-0800
Tony Lewellen

File details come from the government source that posted it. Updated .