PDX 2026-2 (4) F0.01.pdf
PDF 223 KB Posted
- Solicitation number
- 148221
- Issued by
- Multnomah County, Oregon
About this file
This file is a symbols, legends, and abbreviations reference sheet for the Portland International Airport Fire Protection Replacements project in Oregon. The document serves as a design standard for fire protection systems and provides comprehensive guidance on the graphical symbols, terminology, and abbreviations used throughout the project drawings. The sheet includes standard fire protection abbreviations, piping connection symbols, valve types, sprinkler head designations, and zone identification boxes. A water flow test conducted on May 20, 2020, at hydrant #007 established the basis of design with static pressure of 92 PSI, residual pressure of 78 PSI, and flow of 893 GPM. The design incorporates a 10 percent PSI cushion above specified pressure requirements and adheres to NFPA 13 standards, airport insurance requirements, and local codes for fire sprinkler system location, sizing, and installation.
The document does not contain pricing information, contract terms, set-asides, funding sources, or other commercial terms. As a technical reference sheet dated November 2026, it is designed to ensure consistency and clarity across all project drawings related to the terminal utility tunnel sprinkler replacements at Portland International Airport. The sheet explicitly notes that it is a standard legend document, and some symbols included may not appear on all project drawings.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10/26/2026
C
AN
Y O
U S
EE
T
H E
AI
R
PL
AN
ES
T H
E
AD
JA
C
EN
T
SA
M
PL
ES
S H
O W
T H
R
EE
D
IF
FE
R
EN
T
LE
VE
LS
O
F
SH
AD
IN
G
SE
TT
IN
G
S
FO
R V
IE
W
IN
G
A N
D P
R
IN
TI
N
G D
R
AW
IN
G
C O
N
TE
N T
AR
E
O
PT
IM
IZ
ED
W
H
EN
AL
L
TH
R
EE
P
LA
N
ES
A
R E
VI
SI
BL
E.
T H
IS
G
U
ID
AN
C
E
IS
P R
O
VI
D
ED
F O
R R
EF
ER
EN
C
E O
N
LY
PRINTED:
lig ht da rk gr ay bl ac k
DESIGN NUMBER PROJECT NUMBER
2"
G R
AP
H
IC
S
C
AL
E
- F
O R
R
EF
ER
EN
C E
O N
LY
gr ay
2:41:16 PM CIMINS r:\aviation\pdx\2026\0002 - terminal utility tunnel sprinkler replacements\sheets - fire\symbols-legend-abbrevs.dwg
DISC. SHT. NO.
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"
DESIGN BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
SUBMITTED BY
DRAWING NO.
TYPE:
1/
4" 1/
2" 1"
1/
4" 1/
2" 1"
DATE BY REVISION APPDATE BY REVISION APP ##
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
PORTLAND INTERNATIONAL AIRPORT
FIRE PROTECTION REPLACEMENTS
SYMBOLS, LEGENDS AND ABBREVIATIONS - FIRE PROTECTION
TONY LEWELLEN
T. LEWELLEN
S. CIMINO
T. LEWELLEN
NOVEMBER 2026
4 CD
PDX 2026-2 F0.012024D035 103022
RE
*,6
7ERED 3R2)E66,21$/
$17+21< C� /E:E//E1
DECE0%ER 0 � � �0 ��
E;3� �������0��
2RE*21
�0���
E1*,1EER
WITHOUT
WITH
WATER PRESSURE DROP
WATER GAUGE
WIDTH
VERTICAL
VELOCITY
TYPICAL
TOTAL STATIC PRESSURE
TEMPERATURE
STRUCTUR(E)(AL)
STEEL
STAINLESS STEEL
SQUARE INCH(ES)
SQUARE FOOT(FEET)
SQUARE
SIMULAR
SENSIBLE
SECTION
STANDARD CUBIC FEET PER MINUTE
SWAY BRACE
REVOLUTIONS PER MINUTE
ASSEMBLY
REDUCED PRESSURE BACKFLOW
RISER NIPPLE
ROOM MANIFOLD
REVISION
PRESSURE SWITCH
PHASE
OUTSIDE DIAMETER
ON CENTER DISTANCE
NOT TO SCALE
NORMALLY OPEN
NOT IN CONTRACT
NORMALLY CLOSED
MOUNTED
MISCELLANEOUS
MINIMUM
MANUFACTURER
MECHANICAL
THOUSAND BTU PER HOUR
MAXIMUM
LINEAR FEET
POUND
LENGTH
KILOWATT HOUR
KILOWATT
ISOLAT(OR)(ION)
INSULATION
INCH(ES)
HANGER
HORSEPOWER
HORIZONTAL
GATE VALVE
GALLONS PER MINUTE
GALLONS PER HOUR
GLYCOL
GALVANIZED
GALLON
GAGE/GAUGE
GRADE
FUTURE
FLOW SWITCH
FEET PER SECOND
FEET PER MINUTE
FLEXIBLE
FIGURE
FIRE DEPARTMENT CONNECTION
DEGREES FAHRENHEIT
EXPANSION
EXISTING
EQUIPMENT
EQUAL
ENGINEER
ELEVATION
ELECTRIC(AL)
EXTENDED COVRAGE
DRAWING
DOWN
DROP NIPPLE
DUCTILE IRON PIPE
VALVE ASSEMBLY
DOUBLE DETECTOR CHECK
CENTERLINE
CONTINUE(ED)(UATION)
CONNECT(ION)
CONCRETE
BUTTERFLY VALVE
BASEMENT
BUILDING
BOTTOM OF DECK
BOTTOM OF BEAM
AUTOMATIC
ARCHITECT(URAL)
APPROXIMATELY
ALTERNATIVE
ABOVE FINISHED FLOOR
ABANDON IN PLACE
W/O W/
WPD
WG
W
VERT
VEL
TYP
TSP
TEMP
STRUCT
STL
SS
SQ IN
SF
SQ
SIM
SENS
SECT
SCFM
SB
RPM
RPBA
RN
RM
REV
PS
PH
OD
OC
NOT TO SCALE
NO
NIC
NC
MTD
MISC
MIN
MFR
MECH
MBH
MAX
LF
LB
L
KWH
KW
ISOL
INSUL
IN
HR
HP
HORIZ
GV
GPM
GPH
GLY
GALV
GAL
GA
G
FUT
FS
FPS
FPM
FLEX
FIG
FDC
EXP
EXIST
EQUIP
EQ
ENGR
ELEV
ELEC
EC
DWG
DN
DN
DIP
DCVA
CL
CONT
CONN
CONC
BV
BSMT
BLDG
BOD
BOB
AUTO
ARCH
APPROX
ALT
AFF
(A)
STANDARD FIRE PROTECTION ABBREVIATIONS:
HORIZONTAL SIDE WALLHSW
AUTOMATIC SPRINKLERAS
BOTTOM OF PIPEBOP
BOTTOM OF RISERBOR
CHECK VALVECV
F
FLOOR FLANGE
FINISHED FLOOR
FFL
FF
FIRE HOSE STATION
FIRE HOSE CABINET
FHS
FHC
FEET/FOOTFT
HEIGHTH
INSIDE (DIAMETER/DIMENSION)
HOSE VALVE
ID
HV
INVERT ELEVATIONIE
OPEN BAR JOISTOBJ
OUTSIDE YOKE & SCREWOS & Y
POST INDICATOR VALVEPIV
POUNDS PER SQUARE INCH
PRESSURE REDUCING VALVE
POLYPROPYLENE
PSI
PRV
PP
SPECIFICATION
STATIC PRESSURE
SHUT OFF VALVE
SPEC
SP
SOV
STANDARD SPRAY UPRIGHTSSU
STANDARD SPRAY PENDENTSSP
TAMPER SWITCHTS
SYMBOLS:
RELOCATE EXISTING
REMOVE EXISTINGCONNECT TO EXISTING
CAP EXISTING / CAP FOR FUTURE
NOTEEXISTING TO REMAIN
R
E
XC
K
A ACCESS PANEL
BELOW GRADE / FLOORB
CALL OUT SYMBOLS
DESIGN CUSHION: PROVIDE AN EXCESS OF 10% PSI ADDITIONAL PRESSURE REQUIREMENTS
INCORPORATED INTO THE DESIGN OVER SPECIFIED PRESSURE REQUIREMENTS.
REFER TO DRAWINGS FOR ZONE TYPES, CALLOUTS AND ADDITIONAL SCOPE ITEMS.
USE NFPA 13 FOR THE LOCATION, SIZING & INSTALLATION OF PIPING & SPRINKLER SYSTEMS
DESIGN TO MEET THE AIRPORT, INSURANCE REQUIREMENTS AND LOCAL CODES.
FIRE PROTECTION DESIGN CRITERIA:
FIRE PROTECTION SPRINKLER DESIGN CRITERIA:
PROVIDE THE FOLLOWING HAZARD CLASSIFICATIONS PER NFPA 13 AND AIRPORT STANDARDS.
SEE THE SPECIFICATIONS SECTION 212000 FOR DENSITIES, REMOTE AREAS, AND SPRINKLER
COVERAGES FOR THE LISTED OCCUPANCIES.
WATER SERVICE PRESSURE BASIS OF DESIGN:
PRESSURE USED TO DEVELOP THE FIRE SPRINKLER SYSTEM DESIGN INFORMATION INCLUDED
HEREIN. THE CONTRACTOR SHALL BE REQUIRED TO OBTAIN CURRENT FLOW TEST
INFORMATION PRIOR TO STARTING THEIR DESIGN OF THE FIRE SPRINKLER SYSTEM.
WATER FLOW INFORMATION, HYDRANT #007 (05/20/2020): STATIC: 92 PSI; RESIDUAL; 78 PSI;
FLOW: 893 GPM.
MC
MECHANICAL COUPLING
BALL JOINT
FLEXIBLE CONNECTION
TEE DOWN
TEE UP
ELBOW DOWN
ELBOW UP
RISER
PLUG OR BLIND FLANGE
CAP
FLANGED CONNECTION
UNION
JOINT OR COUPLING POINT
CROSS
TEE
ELBOW (45°)
ELBOW (90°)
ANCHOR
REDUCER
PIPE SLEEVE
DIRECTION OF SLOPE
DIRECTION OF FLOW
HORIZONTAL TEE
PIPING CONNECTIONS
HEAT TRACE
MISC. FITTINGS & SYMBOLS:
DCVA DOUBLE CHECK VALVE ASSEMBLY
GROUND HYDRANTGHG
SHUT-OFF VALVE
GLOBE VALVE
SHUT-OFF VALVE W/ TAMPER SWITCH
TRIPLE DUTY VALVE
CHECK VALVE
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
PRESSURE REDUCING VALVE
BALANCING VALVE
FLOW CONTROL VALVE
SOLENOID VALVE
RELIEF VALVE
AIR VENT (MANUAL/AUTOMATIC)
STRAINER
STRAINER W/ BLOWDOWN
DRAIN VALVE
WALL HYDRANT
STEAM TRAP
PRESSURE GAUGE
PRESSURE/TEMPERATURE TEST PLUG
THERMOMETER
FLOW SWITCH
TEMPERATURE TRANSMITTER
SHOCK ARRESTOR
VACUUM BREAKER
WATER FLOW METER
REDUCED PRESSURE BACKFLOW ASSEMBLY
DOUBLE CHECK DETECTOR ASSEMBLY
BACKWATER VALVE
UNDERGROUND GATE VALVE W/BOX
UNDERGROUND GATE W/POST INDICATOR
OUTSIDE SCREW & YOKE
Y PATTERN BOILER BLOWDOWN VALVE
NON-RETURN STOP VALVE
QUICK OPENING BOILER BLOWDOWN VALVE
DV
AAVMAV
S
FC
S
HOSE BIBBHB
WH
F
T
(SIZE)S
V
WFM
RPBA
DCDA
BWV
UG
PIV
F&T/IB
GENERAL NOTE:
THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY
APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.
MISC. VALVES & COCKS:
FULL ZONE IDENTIFICATION
BUILDING
LOCATION
FLOOR/LEVEL
ZONE NUMBER
TYPE OF SYSTEM
EXTENSION - TERMINAL - SOUTH EAST - FLOOR 1 - ZONE 1 - WET
ABBREVIATION ZONE IDENTIFICATION
EX-T-SE-1-2-W
BUILDINGS LOCATION FLOOR/LEVEL TYPE OF SYSTEMS
A - CONCOURSE 'A'
B - CONCOURSE 'B'
C - CONCOURSE 'C'
D - CONCOURSE 'D'
E - CONCOURSE 'E'
EX - EXTENSION
T - TERMINAL
A - ALL
C - CENTERAL
N - NORTH
E - EAST
S - SOUTH
W - WEST
UT - TUNNEL
1 - DEPLANING
2 - ENPLANING
3 - MEZZANINE
4 - PENTHOUSE
W - WET
D - DRY
O - DELUGE
PA - PREACTION
SP - STANDPIPE
FIRE SPRINKLER ZONE BOUNDRY
IDENTIFICATION BOXES
PIPE ZONE IDENTIFICATION BOXES
GENERAL NOTE:
CW - CONC. WALKWAY
ZONE NUMBER
1 - ZONE 1
2 - ZONE 2
3 - ZONE 3
4 - ZONE 4
5 - ZONE 5
CA - CLEAN AGENT
FP
PENDANT SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
STANDPIPE OUTLET
STANDPIPE ROOF CONNECTION
FIRE DEPARTMENT CONNECTION
FIRE SPRINKLER
FIRE PROTECTION
DRY PIPE SPRINKLER
FP
SPR
DP
PA PRE-ACTION SYSTEM
DRY STANDPIPE
WET STANDPIPEWSP
DSP
SIDEWALL SPRINKLER HEAD
SUPERVISED SHUT-OFF VALVE
DRY PIPE VALVE ASSEMBLY
FLOW SWITCH
DPV
PRE-ACTION VALVE ASSEMBLYPAV
S
SO
SRC
FDC
F
COMBINATION STANDPIPECSP
FIRE PROTECTION SYMBOLS:
AREA OF WORK:
AREA WITHIN THIS LINE IDENTIFIES SCOPE
OF WORK PER NOTE
DEMOLITION LEGEND:
REMOVE EXISTING PIPE
REMOVE EXISTING SPRINKLER
NEW AND EXISTING WORK:
EXISTING PIPE
EXISTING SPRINKLER
NEW PIPE
NEW SPRINKLER
B-SE-1-1-W
CONCOURSE OR TERMINAL
LEVEL SPRINKLER ZONE -
TYPE
| 2026-11-10T12:07:33-0800 | |
| Tony Lewellen |
File details come from the government source that posted it. Updated .