PART 6 ATTACHMENT M2 309 M-102.pdf
PDF 312 KB Posted
- Solicitation number
- N6247020R6009
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MIN. 4 SHOWERS
4 WC
2 URINALS
4 LAVS
MIN. 3 SHOWERS
4 WC
3 LAVS
BILLETING
X
BILLETING
X
HEAD CORRIDOR
X
MECHANICAL
X
MEN
X
TELEPHONE
X
VIP SLEEPING
X
VIP SLEEPING
X
VIP HEAD
X
VIP HEAD
X
WOMEN
X
BILLETING
X
BILLETING
X
MECHANICAL
X
FEMALE
LOUNGE
X
FEMALE
BILLETING
X
STAIR
X
STAIR
X
JANITOR
X
PROGRESS
DRAWING - DO NOT
USE FOR
CONSTRUCTION
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com
NC# P-0506
c
Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
DISCLOSURE OF INFORMATION:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED
INFORMATION, REGARDLESS OF MEDIUM (E.G. FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT
OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL;
OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF THE RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT.
SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR
TO THE CONTRACTING OFFICER.
1/8" = 1'-0"
0 8' 16'4'
SECOND FLOOR PLAN
PLAN
NORTH
KEYED NOTES
PLANS INDICATE SUGGESTED HVAC ZONES. REFER TO PLAN 1/M-105 FOR SUGGESTED
SYSTEM ARRANGEMENTS.
THE EXISTING STRUCTURE WILL LIMIT CEILING HEIGHTS. CONTRACTOR SHALL MAKE
EVERY EFFORT TO MAXIMIZE CEILING HEIGHTS. UNDER NO CIRCUMSTANCES WILL THE
CEILINGS BE BELOW 7'-10” ABOVE FINISHED FLOOR.
DUCTWORK, BRANCH CIRCUIT CONTROLLERS AND REFRIGERANT PIPING SHALL
ROUTED/INSTALLED IN MECHANICAL SPACES. CONTRACTOR SHALL MAXIMIZE AVAILABLE
SPACE FOR FUTURE IN THOSE AREAS.
CONTRACTOR MAY GATHER FAN COIL UNIT CONDENSATE PIPING INTO GROUPS, BUT
EACH FAN COIL SHALL REMAIN INDIVIDUALLY GRAVITY DRAINED. CONDENSATE PIPING
SHALL BE ROUTED DOWN INSIDE EXTERIOR WALLS AND PENETRATE THE EXTERIOR
WALL JUST ABOVE THE FIRST FLOOR. CONDENSATE DRAINS SHALL SPILL ONTO A
SPLASH BLOCK.
PROVIDE AND INSTALL DUCTLESS SYSTEM AIR-HANDLING UNITS ABOVE DOOR OR AS
CONSTRUCTION ALLOWS, NOT INTERFERING WITH COMM EQUIPMENT LAYOUT.
1 2
TYP.
1 2
TYP.
1 2
TYP.
1 2
TYP.
1 2
TYP.
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SATISFACTORY TO: DATE
AutoCAD SHX Text
APPROVED: PWO OR OICC DATE
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
DES.
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text
CONST. CONTR.
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text F
AutoCAD SHX Text
SIZE
AutoCAD SHX Text 80091
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
CODE IDENT. NO
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text 18168
AutoCAD SHX Text
RENOVATION TO
AutoCAD SHX Text
BUILDING 309
AutoCAD SHX Text 19-0155
AutoCAD SHX Text N/A
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DRAFT
AutoCAD SHX Text
T H BURTON, PE
AutoCAD SHX Text M-102
AutoCAD SHX Text
BUILDING 309
AutoCAD SHX Text
SECOND FLOOR PLAN
AutoCAD SHX Text
AutoCAD SHX Text
GRM
AutoCAD SHX Text
GRM
AutoCAD SHX Text
DMH
AutoCAD SHX Text
| Sheets and Views |
| M-102 |
| OLE1 |
File details come from the government source that posted it. Updated .