PART 6 ATTACHMENT A6 A105 BLDG309 WALL SECTION.pdf

PDF 352 KB Posted

Attached to
Design-Build Hadnot Point Facility Repairs, Building 309
Solicitation number
N6247020R6009
Issued by

View the file

Other files

File Type Posted
Amnd 0005 20R6009.pdf PDF
Amnd 0004 20R6009.pdf PDF
20-0040 Part 3 25 June 20.pdf PDF
20-0040 Part 3 062420.pdf PDF
PART 6 ATTACHMENT A6 A105A - BLDG309 SECTION 062420.pdf PDF
20-0040 PART 4 062420.pdf PDF
Amnd 0003 20R6009.pdf PDF
PART 6 ATTACHMENT A7 ARCHITECTURAL SHEETS 062420.pdf PDF
Amnd 0002 20R6009.pdf PDF
20-0040 Part 3 061120 REV.pdf PDF
20-0040 PART 4 061120 REV.pdf PDF
Amnd 0001 20R6009.pdf PDF
Master PPI Form Template.xlsx XLSX spreadsheet
Part 6 ATTACHMENT N EXAMPLE SCREEN WALL.pdf PDF
Part 6- ATTACHMENT A12- ADA Checklist for Existing Buildings.pdf PDF
20-0040 PART 6 TOC.pdf PDF
PART 6 ATTACHMENT A5 A104 BLDG309 RENO PLAN L2.pdf PDF
Part 6 ATTACHMENT O MCBCL Base-Wide MNS-FACP Construction Requirements.pdf PDF
PART 6 ATTACHMENT M1 309 M-101.pdf PDF
20-0040-PART 3 COVER.pdf PDF
20-0040 PART 2 HADNOT POINT FACILITY REPAIRS BLDG 309.pdf PDF
PART 6 ATTACHMENT A8 ADA CHECKLIST FOR EXISTING BLDGS.pdf PDF
20-0040-PART 2 COVER.pdf PDF
PART 6 ATTACHMENT A4 A103 BLDG309 RENO PLAN L1.pdf PDF
PART 6 ATTACHMENT E1 309 TS101.pdf PDF
PART 6 ATTACHMENT A1 A100 BLDG309 ROOM FINISH SCHEDULE.pdf PDF
PART 6 ATTACHMENT A7 ARCHITECTURAL SHEETS.pdf PDF
PART 6 ATTACHMENT K_MCO 5110.6C.pdf PDF
Part 6 ATTACHMENT D1- ASBESTOS REPORT.pdf PDF
PART 6 ATTACHMENT A9 MCBCL SIGNS STANDARDS-GRAPHICS.pdf PDF
20-0040 PART 4 COVER.pdf PDF
PART 6 ATTACHMENT A2 A101 BLDG309 DEMO PLAN L1.pdf PDF
PART 6 ATTACHMENT G3 1997 Bldg 309 AS BUILTS.pdf PDF
PART 6 ATTACHMENT L MCBCL Mech Design Guidance 7.17.pdf PDF
PART 6 ATTACHMENT G2 56-3564 Modification of Barracks.pdf PDF
Part 6- ATTACHMENT C1 C100 BLDG 309 SITE PLAN.pdf PDF
RFP 20R6009.pdf PDF
PART 6 ATTACHMENT M3 309 M-601.pdf PDF
PART 6 ATTACHMENT F_NPDES PERMIT NCS000290.pdf PDF
PART 6 ATTACHMENT A3 A102 BLDG309 DEMO PLAN L2.pdf PDF
20-0040 PART 6 COVER.pdf PDF
20-0040 PART 5 COVER.pdf PDF
PART 6 ATTACHMENT E2 309 T-101.pdf PDF
Part 6- ATTACHMENT B- MCB Camp Lejeune Base Exterior Architectural Plan (BEAP).pdf PDF
20-0040 PART 4.pdf PDF
PART 6 ATTACHMENT M2 309 M-102.pdf PDF
20-0040 PART 5 HADNOT POINT FACILITY REPAIRS BLDG 309.pdf PDF
PART 6 ATTACHMENT J_MCO 5530.14A.pdf PDF
Part 6 ATTACHMENT A10 20-0040 GENERAL NOTES.pdf PDF
Part 6 ATTACHMENT D2- APPENDIX D BUILDING INFORMATION CHECKLIST.pdf PDF
Show 40 more

Latest 50 of 51 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING BRICK VENEER, AIR SPACE, VAPOR BARRIER, SHEATHING, METAL STUD, BRICK TIES TO REMAIN-DO NOT DISTURB. TYP ENTIRE EXTERIOR WALL

INSTALL FROM OUTSIDE TO INSIDE (TYP ENTIRE EXTERIOR WALL LEVELS 1 AND 2):

1. INSTALL 3 5/8” 16 GA STUD WALL INCLUDING CONT. TOP & BOTTOM TRACK. SPACE VERTICAL STUDS 12” O.C. AT THE INSIDE PLANE OF THE NEW GYPSUM SHEATHING. NEW

WALL MUST SUPPORT EXISTING FLOOR JOIST ABOVE. ENSURE THAT A STUD IS PLACED BENEATH EACH JOIST. REQUIRED AT ALL EXTERIOR WALLS.

2. INSTALL R13 BATT-INSULATION AT 3 5/8” STUD WALL. REQUIRED AT ALL EXTERIOR WALLS.

3. INSTALL 5/8” MOISTURE RESISTANT GWB FASTENED TO 3 5/8” STUD WALL. REQUIRED AT ALL EXTERIOR WALLS.

4. THE R-VALUE OF THE WALL ASSEMBLY MUST MEET OR EXCEED ASHRAE 90.1 - 2016 TYP. ALL EXTERIOR WALLS

IN LOCATIONS WHERE SLAB IS DEPRESSED, INFILL CONCRETE BENEATH NEW STUD WALL FLUSH WITH ADJACENT FLOOR

FILL CAVITY ABOVE NEW METAL STUD WALL, REINFORCED EXTERIOR WALL CONDITION, AND BOTTOM OF SLAB WITH POLYURETHANE SPRAY FOAM INSULATION AS

NECESSARY TO ENSURE CONTINUITY OF SIMILAR MATERIALS.

BEARING STUD WALL: REQUIRED IN ALL EXTERIOR WALLS.

REPLACE BRICK AND MORTAR ROWLOCK AND STRETCHER COURSES TO MATCH EXISTING. INSTALL NEW THROUGH-WALL FLASHING, SEAL TO EXTERIOR FACE OF EXISTING SHEATHING. INSTALL 1” VERTICAL WEEP HOLES IN ROWLOCK COURSE APPROX. 60” O.C.

ENSURE CLEAR DRAINAGE PATH. INSTALL APPROVED WEEP VENTS

SEE ABOVE FOR DETAILED DESCRIPTION

INSTALL APPROVED THROUGH-WALL FLASHING. ATTACH TO EXISTING SHEATHING WITH TERMINATION BAR FASTENED TO STUDS. SEAL TOP OF

TERMINATION BAR WITH APPROVED SEALANT

REFER TO GENERAL NOTES FOR WORK IN CRAWL SPACE

FILL CAVITY ABOVE NEW METAL STUD WALL, REINFORCED EXTERIOR WALL CONDITION AND ROOF DECK WITH POLYURETHANE SPRAY FOAM INSULATION AS NECESSARY

TO ENSURE CONTINUITY OF SIMILAR MATERIALS.

CEILING SYSTEM LOCATION IN BOTH LEVELS IS ARBITRARY AND NOT TO SCALE. INSTALL AS TIGHT AS POSSIBLE TO THE STRUCTURE ABOVE. TYPICAL ALL

FLOORS AND CONDITIONS

NEW INSULATION.

EXISTING FASCIA, SOFFIT, TRIM, MOLDING, ROOFING AND ROOF WOOD PLANKS, ATTIC

INSULATION, GUTTERS AND DOWNSPOUTS. TYPICAL ENTIRE EXTERIOR WALLS AND ROOFS

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

EXISTING BRICK VENEER, BRICK TIES, AIR SPACE, SHEATHING, METAL STUD TO REMAIN-DO NOT

DISTURB. TYPICAL AT ALL EXTERIOR WALLS

DEMOLISH EXISTING FURRING CHANNELS AND GWB FROM CONCRETE SLAB TO STRUCTURE

ABOVE. TYPICAL BOTH FLOORS AND AT ALL EXTERIOR WALLS

DO NOT DISTURB EXISTING JOIST SYSTEM AND END CHANNEL

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

DEMOLISH 1 ROWLOCK AND 2 STRETCHER COURSEs AND FLASHING. PROTECT VAPOR

BARRIER AND SHEATHING AS NECESSARY. TYPICAL THROUGH OUT ALL EXTERIOR WALLS.

MAXIMUM 48" HORIZONTAL SECTION REMOVAL AT ONE TIME UNLESS APPROVED BY THE

COR. PROVIDE TEMPORARY SUPPORT AS REQUIRED TO MAINTAIN INTEGRITY OF EXISTING

CONDITIONS. CLEAN CAVITY AND REMOVE ALL EXCESS MORTAR

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

REFER TO GENERAL NOTES FOR WORK IN CRAWL SPACE

SHEET:

80091

E1

MARINE CORPS BASE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

CAMP LEJEUNE, NORTH CAROLINA

DESIGN DIR.

SUBMITTED BY:

NAVFAC DRAWING NO.CODE IDENT. NOSIZE

SPEC.SCALE:

SATISFACTORY TO:

APPROVED: PWO OR OICC:

DR.

DES.

CHK.

CONST. CONTR. NO.

DATE:

DATE:

OF

NTS

EXTERIOR WALL 313 - DEMO

A105

NTS

EXTERIOR WALL 313 - RENO

A105

AutoCAD SHX Text NOTES: 1. THE DESIGNER OF RECORD MUST FIELD VERIFY ALL THE CONDITIONS SHOWN. THESE DETAILS AND RECOMMENDATIONS MUST NOT BE CONSIDERED THE FINAL DESIGN. IT IS THE DESIGNER OF RECORD RESPONSIBILITY TO REPRESENT THE SCOPE OF WORK IN THE DESIGNER OF RECORD MUST FIELD VERIFY ALL THE CONDITIONS SHOWN. THESE DETAILS AND RECOMMENDATIONS MUST NOT BE CONSIDERED THE FINAL DESIGN. IT IS THE DESIGNER OF RECORD RESPONSIBILITY TO REPRESENT THE SCOPE OF WORK IN SUFFICIENT DETAILS IN THE DRAWINGS AND TO DESCRIBE IT IN SUFFICIENT DETAIL IN THE SPECIFICATIONS. THE SECTIONS AND DETAILS ARE GENERIC IN NATURE AND NOT THE FINAL CONFIGURATION. THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CALCULATIONS TO DETERMINE APPROPRIATE MATERIALS, LOADS, CODE COMPLIANCE REQUIREMENTS, ETC. 2. THE DESIGNER OF RECORD MUST PRESENT THE PROPOSED SOLUTION(S) DURING THE CDW TO ENSURE THAT IT IS CONSISTENT WITH THE DESIGN INTENT OF THE MCBCL THE DESIGNER OF RECORD MUST PRESENT THE PROPOSED SOLUTION(S) DURING THE CDW TO ENSURE THAT IT IS CONSISTENT WITH THE DESIGN INTENT OF THE MCBCL 3. THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CODE COMPLIANCE ANALYSIS BASED ON OCCUPANCY TO DETERMINE THE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES, REQUIRED EXITS, ETC. ALL THE FLOOR PLAN LAYOUTS MUST BE THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CODE COMPLIANCE ANALYSIS BASED ON OCCUPANCY TO DETERMINE THE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES, REQUIRED EXITS, ETC. ALL THE FLOOR PLAN LAYOUTS MUST BE APPROVED BY THE USER AT THE CDW. THIS APPLIES TO: THE SCOPE OF WORK (SOW) SHOWN WITHIN BLOCKED AREAS ON THE DRAWINGS DEVELOPED FLOOR PLAN LAYOUTS SHOWING FOR EXAMPLE: TOILET FIXTURES, FURNITURE, CABINETS, EXITS, ETC. ARE GENERIC IN NATURE AND NOT THE FINAL CONFIGURATION 4. CRAWL SPACE VAPOR BARRIER (VB): INFILL DEPRESSED AREAS WITH SOIL, PROPERLY GRADED AND SMOOTH TO RECEIVE NEW VB (12 MIL MINIMUM). OVERLAP 6" MINIMUM AT ALL HORIZONTAL VB CONDITIONS. BRING HORIZONTAL VB UNINTERRUPTED UP TO CRAWL SPACE VAPOR BARRIER (VB): INFILL DEPRESSED AREAS WITH SOIL, PROPERLY GRADED AND SMOOTH TO RECEIVE NEW VB (12 MIL MINIMUM). OVERLAP 6" MINIMUM AT ALL HORIZONTAL VB CONDITIONS. BRING HORIZONTAL VB UNINTERRUPTED UP TO THE FOUNDATION WALLS A MINIMUM OF 12", SECURE WITH INSECT/MOISTURE RESISTANT LUMBER STRIPS 1x2 MINIMUM CONTINUOUSLY IN ALL FOUNDATIONS FASTENED AT 12" O.C AND CAULK BETWEEN TOP OF STRIP AND FOUNDATION WALL 5. INTERIOR WALL TYPES: IN GENERAL INTERIOR WALLS ARE CMU, EXCEPT BUILDING 320 CMU WITH PLASTER, AND 1707 CMU WITH FURRED OUT GWB. FIELD VERIFY THESE CONDITIONS. INTERIOR WALL TYPES: IN GENERAL INTERIOR WALLS ARE CMU, EXCEPT BUILDING 320 CMU WITH PLASTER, AND 1707 CMU WITH FURRED OUT GWB. FIELD VERIFY THESE CONDITIONS.

AutoCAD SHX Text DISCLOSURE OF INFORMATION CONTRACTOR SHALL COMPLY AS FOLLOWS: A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CON- TRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS: (1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR (2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE. B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE. C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

AutoCAD SHX Text

PRELIMINARY 30 APRIL 2020

AutoCAD SHX Text A105

AutoCAD SHX Text

MARK RAMSDELL

AutoCAD SHX Text

MARK RAMSDELL

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text

MARK RAMSDELL

AutoCAD SHX Text

THOMAS BURTON

AutoCAD SHX Text PWO or OICC

AutoCAD SHX Text

FACILITY REPAIRS, HADNOT POINT

AutoCAD SHX Text

BLDG 309

AutoCAD SHX Text

BUILDING SECTION

AutoCAD SHX Text

60XXXXX

AutoCAD SHX Text 20-0040

AutoCAD SHX Text

NOTED

AutoCAD SHX Text

NA

AutoCAD SHX Text

AutoCAD SHX Text

XX

Sheets and Views
A105 - 309 Section)

File details come from the government source that posted it. Updated .