PART 6 ATTACHMENT A6 A105A - BLDG309 SECTION 062420.pdf

PDF 525 KB Posted

Attached to
Design-Build Hadnot Point Facility Repairs, Building 309
Solicitation number
N6247020R6009
Issued by

View the file

Other files

File Type Posted
Amnd 0005 20R6009.pdf PDF
Amnd 0004 20R6009.pdf PDF
20-0040 Part 3 25 June 20.pdf PDF
20-0040 Part 3 062420.pdf PDF
20-0040 PART 4 062420.pdf PDF
Amnd 0003 20R6009.pdf PDF
PART 6 ATTACHMENT A7 ARCHITECTURAL SHEETS 062420.pdf PDF
Amnd 0002 20R6009.pdf PDF
20-0040 Part 3 061120 REV.pdf PDF
20-0040 PART 4 061120 REV.pdf PDF
Amnd 0001 20R6009.pdf PDF
Master PPI Form Template.xlsx XLSX spreadsheet
Part 6 ATTACHMENT N EXAMPLE SCREEN WALL.pdf PDF
PART 6 ATTACHMENT A6 A105 BLDG309 WALL SECTION.pdf PDF
Part 6- ATTACHMENT A12- ADA Checklist for Existing Buildings.pdf PDF
20-0040 PART 6 TOC.pdf PDF
PART 6 ATTACHMENT A5 A104 BLDG309 RENO PLAN L2.pdf PDF
Part 6 ATTACHMENT O MCBCL Base-Wide MNS-FACP Construction Requirements.pdf PDF
PART 6 ATTACHMENT M1 309 M-101.pdf PDF
20-0040-PART 3 COVER.pdf PDF
20-0040 PART 2 HADNOT POINT FACILITY REPAIRS BLDG 309.pdf PDF
PART 6 ATTACHMENT A8 ADA CHECKLIST FOR EXISTING BLDGS.pdf PDF
20-0040-PART 2 COVER.pdf PDF
PART 6 ATTACHMENT A4 A103 BLDG309 RENO PLAN L1.pdf PDF
PART 6 ATTACHMENT E1 309 TS101.pdf PDF
PART 6 ATTACHMENT A1 A100 BLDG309 ROOM FINISH SCHEDULE.pdf PDF
PART 6 ATTACHMENT A7 ARCHITECTURAL SHEETS.pdf PDF
PART 6 ATTACHMENT K_MCO 5110.6C.pdf PDF
Part 6 ATTACHMENT D1- ASBESTOS REPORT.pdf PDF
PART 6 ATTACHMENT A9 MCBCL SIGNS STANDARDS-GRAPHICS.pdf PDF
20-0040 PART 4 COVER.pdf PDF
PART 6 ATTACHMENT A2 A101 BLDG309 DEMO PLAN L1.pdf PDF
PART 6 ATTACHMENT G3 1997 Bldg 309 AS BUILTS.pdf PDF
PART 6 ATTACHMENT L MCBCL Mech Design Guidance 7.17.pdf PDF
PART 6 ATTACHMENT G2 56-3564 Modification of Barracks.pdf PDF
Part 6- ATTACHMENT C1 C100 BLDG 309 SITE PLAN.pdf PDF
RFP 20R6009.pdf PDF
PART 6 ATTACHMENT M3 309 M-601.pdf PDF
PART 6 ATTACHMENT F_NPDES PERMIT NCS000290.pdf PDF
PART 6 ATTACHMENT A3 A102 BLDG309 DEMO PLAN L2.pdf PDF
20-0040 PART 6 COVER.pdf PDF
20-0040 PART 5 COVER.pdf PDF
PART 6 ATTACHMENT E2 309 T-101.pdf PDF
Part 6- ATTACHMENT B- MCB Camp Lejeune Base Exterior Architectural Plan (BEAP).pdf PDF
20-0040 PART 4.pdf PDF
PART 6 ATTACHMENT M2 309 M-102.pdf PDF
20-0040 PART 5 HADNOT POINT FACILITY REPAIRS BLDG 309.pdf PDF
PART 6 ATTACHMENT J_MCO 5530.14A.pdf PDF
Part 6 ATTACHMENT A10 20-0040 GENERAL NOTES.pdf PDF
Part 6 ATTACHMENT D2- APPENDIX D BUILDING INFORMATION CHECKLIST.pdf PDF
Show 40 more

Latest 50 of 51 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXTERIOR WALL - DEMO1 EXTERIOR WALL - RENO2

AutoCAD SHX Text IN LOCATIONS WHERE SLAB IS DEPRESSED, INFILL CONCRETE BENEATH NEW STUD WALL FLUSH WITH ADJACENT FLOOR

AutoCAD SHX Text FILL CAVITY ABOVE NEW METAL STUD WALL, REINFORCED EXTERIOR WALL CONDITION, AND BOTTOM OF SLAB WITH POLYURETHANE SPRAY FOAM INSULATION AS NECESSARY TO ENSURE CONTINUITY OF SIMILAR MATERIALS.

AutoCAD SHX Text

BEARING STUD WALL: REQUIRED IN ALL EXTERIOR WALLS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REPLACE BRICK AND MORTAR ROWLOCK AND STRETCHER COURSES TO MATCH EXISTING. INSTALL NEW THROUGH-WALL FLASHING, SEAL TO EXTERIOR FACE OF EXISTING SHEATHING. INSTALL 1” VERTICAL WEEP HOLES IN ROWLOCK COURSE VERTICAL WEEP HOLES IN ROWLOCK COURSE APPROX. 60” O.C. ENSURE CLEAR DRAINAGE PATH. INSTALL APPROVED WEEP VENTS O.C. ENSURE CLEAR DRAINAGE PATH. INSTALL APPROVED WEEP VENTS

AutoCAD SHX Text INSTALL APPROVED THROUGH-WALL FLASHING. ATTACH TO EXISTING SHEATHING WITH TERMINATION BAR FASTENED TO STUDS. SEAL TOP OF TERMINATION BAR WITH APPROVED SEALANT

AutoCAD SHX Text

SEE ABOVE FOR NEW BOTTOM PLATE REQUIREMENTS

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING FASCIA, SOFFIT, TRIM, MOLDING AND SSMR.

AutoCAD SHX Text FILL CAVITY ABOVE NEW METAL STUD WALL, REINFORCED EXTERIOR WALL CONDITION AND ROOF DECK WITH POLYURETHANE SPRAY FOAM INSULATION AS NECESSARY TO ENSURE CONTINUITY OF SIMILAR MATERIALS.

AutoCAD SHX Text

EXISTING ROOF RAFTERS-DO NOT DISTURB.

AutoCAD SHX Text CEILING SYSTEM LOCATION IN BOTH LEVELS IS ARBITRARY AND NOT TO SCALE. INSTALL AS TIGHT AS POSSIBLE TO THE STRUCTURE ABOVE. TYPICAL ALL FLOORS AND CONDITIONS

AutoCAD SHX Text EXISTING FASCIA, SOFFIT, TRIM, MOLDING, ROOFING AND ROOF WOOD PLANKS, ATTIC INSULATION.

AutoCAD SHX Text

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

AutoCAD SHX Text

DO NOT DISTURB EXISTING JOIST SYSTEM AND END CHANNEL

AutoCAD SHX Text

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

AutoCAD SHX Text

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

AutoCAD SHX Text DEMOLISH 1 ROWLOCK AND 2 STRETCHER COURSEs AND FLASHING. PROTECT VAPOR BARRIER AND SHEATHING AS NECESSARY. TYPICAL THROUGH OUT ALL EXTERIOR WALLS. MAXIMUM 48" HORIZONTAL SECTION REMOVAL AT ONE TIME UNLESS APPROVED BY THE COR. PROVIDE TEMPORARY SUPPORT AS REQUIRED TO MAINTAIN INTEGRITY OF EXISTING CONDITIONS. CLEAN CAVITY AND REMOVE ALL EXCESS MORTAR

AutoCAD SHX Text

SEE OTHER DOCUMENTS FOR EXTENT OF BUILDING INTERIOR DEMOLITION

AutoCAD SHX Text NOTES: 1. THE DESIGNER OF RECORD MUST FIELD VERIFY ALL THE CONDITIONS SHOWN. THESE DETAILS AND RECOMMENDATIONS MUST NOT BE CONSIDERED THE FINAL DESIGN. IT IS THE DESIGNER OF RECORD RESPONSIBILITY TO REPRESENT THE SCOPE THE DESIGNER OF RECORD MUST FIELD VERIFY ALL THE CONDITIONS SHOWN. THESE DETAILS AND RECOMMENDATIONS MUST NOT BE CONSIDERED THE FINAL DESIGN. IT IS THE DESIGNER OF RECORD RESPONSIBILITY TO REPRESENT THE SCOPE OF WORK IN SUFFICIENT DETAILS IN THE DRAWINGS AND TO DESCRIBE IT IN SUFFICIENT DETAIL IN THE SPECIFICATIONS. THE SECTIONS AND DETAILS ARE GENERIC IN NATURE AND NOT THE FINAL CONFIGURATION. THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CALCULATIONS TO DETERMINE APPROPRIATE MATERIALS, LOADS, CODE COMPLIANCE REQUIREMENTS, ETC. 2. THE DESIGNER OF RECORD MUST PRESENT THE PROPOSED SOLUTION(S) DURING THE CDW TO ENSURE THAT IT IS CONSISTENT WITH THE DESIGN INTENT OF THE MCBCLTHE DESIGNER OF RECORD MUST PRESENT THE PROPOSED SOLUTION(S) DURING THE CDW TO ENSURE THAT IT IS CONSISTENT WITH THE DESIGN INTENT OF THE MCBCL

AutoCAD SHX Text

NTS

AutoCAD SHX Text A105A

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text 80091

AutoCAD SHX Text E1

AutoCAD SHX Text

MARINE CORPS BASE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

CAMP LEJEUNE, NORTH CAROLINA

AutoCAD SHX Text

DESIGN DIR.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

CODE IDENT. NO

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SATISFACTORY TO:

AutoCAD SHX Text

APPROVED: PWO OR OICC:

AutoCAD SHX Text

DR.

AutoCAD SHX Text

DES.

AutoCAD SHX Text

CHK.

AutoCAD SHX Text

CONST. CONTR. NO.

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

OF

AutoCAD SHX Text DISCLOSURE OF INFORMATION CONTRACTOR SHALL COMPLY AS FOLLOWS: A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CON- TRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS: (1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR (2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE. B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE. C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

AutoCAD SHX Text A105A

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text

MARK RAMSDELL

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text

MARK RAMSDELL

AutoCAD SHX Text

THOMAS BURTON

AutoCAD SHX Text PWO or OICC

AutoCAD SHX Text

24 JUNE 20

AutoCAD SHX Text

RENOVATIONS OF H-STYLE

AutoCAD SHX Text

BUILDG 303

AutoCAD SHX Text

EXTERIOR ENVELOPE SECTIONS

AutoCAD SHX Text

60XXXXX

AutoCAD SHX Text 20-0040

AutoCAD SHX Text

NOTED

AutoCAD SHX Text

NA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NTS