About this file

This federal solicitation requests proposals for four construction projects at Tinian International Airport in the Commonwealth of the Northern Mariana Islands. The projects include construction of a cargo pad with taxiway extension using Portland cement concrete, including connections to the airfield runway and taxiways, as well as navigational aids, utilities, and supporting facilities. A second project involves construction of a jet fuel system comprising a harbor fuel receipt facility, pipelines, three aboveground storage tanks, additization and pump stations, truck fill stands, fire protection, and spill control. A third project repairs and improves the haul route from the seaport to the airfield. The solicitation includes an option for construction of an aircraft maintenance support facility. Responses are due by the date specified in the solicitation. The agency issuing this solicitation is the Department of the Navy Naval Facilities Engineering Command.

View the file

Other files

File Type Posted
22R1306-Note8.pdf PDF
N6274222R1306_AMD06.pdf PDF
22R1306-Note7.pdf PDF
22R1306-Note6.pdf PDF
N6274222R1306_AMD05.pdf PDF
22R1306-Note5.pdf PDF
22R1306-Note4.pdf PDF
N6274222R1306_AMD04.pdf PDF
22R1306-Note3.pdf PDF
N6274222R1306_AMD03_.pdf PDF
22R1306_Note2.pdf PDF
Virtual Site Visit Participants.pdf PDF
22R1306-Note1.pdf PDF
N6274222R1306_AMD0002_ALL.pdf PDF
N6274222R1306_Amd01.pdf PDF
P-9010 Fuel Tank_Hydr Sys Final_Drawings_3 of 4.pdf PDF
P-9010 Fuel Tank_Hydr Sys Final_Drawings_2 of 4.pdf PDF
P-9030 Cargo Pad_Final_Drawings-updated-1 OF 3.pdf PDF
P-9030 Cargo Pad_Final_Drawings-updated-3 OF 3.pdf PDF
PART A DIV01 Tinian Final Spec Book Vol 1F of 5.pdf PDF
PART C P-9040 Tinian Final Spec Book Vol 3 of 5.pdf PDF
PART A DIV01 Tinian Final Spec Book Vol 1B of 5.pdf PDF
PART D P-9010 Tinian Final Spec Book Vol 4 of 5.pdf PDF
PART A DIV01 Tinian Final Spec Book Vol 1A of 5.pdf PDF
PART A DIV01 Tinian Final Spec Book Vol 1D of 5.pdf PDF
P-9010 Fuel Tank_Hydr Sys Final_Drawings_1 of 4.pdf PDF
P-9021 Offsite Roadways Final_Drawings.pdf PDF
PART A DIV01 Tinian Final Spec Book Vol 1C of 5.pdf PDF
PART E P-9021R Tinian Final Spec Book Vol 5 of 5.pdf PDF
PART A DIV01 Tinian Final Spec Book Vol 1E of 5.pdf PDF
N6274222R1306_RFP.pdf PDF
P-9040 MX Support Facility Final_Drawings.pdf PDF
PART B P-9030 Tinian Final Spec Book Vol 2 of 5.pdf PDF
P-9010 Fuel Tank_Hydr Sys Final_Drawings_4 of 4.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

C-001

GENERAL NOTES

A. TEMPORARY EROSION/SEDIMENTATION CONTROL AND TREE/NATURAL AREA

PROTECTION MEASURES:

1. INSTALL EROSION/SEDIMENTATION CONTROLS PRIOR TO ANY OTHER

SITE PREPARATION WORK (CLEARING, GRUBBING, GRADING OR

EXCAVATION).

2. THE PLACEMENT OF EROSION/SEDIMENTATION CONTROLS MUST BE IN

ACCORDANCE WITH THE EROSION AND SEDIMENTATION CONTROL

PLANS.

3. ANY SIGNIFICANT VARIATION IN MATERIALS OR LOCATIONS OF

CONTROLS OR FENCES FROM THAT SHOWN ON THE APPROVED PLANS

MUST BE APPROVED BY THE CONTRACTING OFFICER.

4. INSPECT THE CONTROLS AND FENCES AT WEEKLY INTERVALS, BEFORE

ANY STORM FROM WHICH SIGNIFICANT RUNOFF IS ANTICIPATED, AND

AFTER EVERY SIGNIFICANT RAINFALL TO ENSURE THEY HAVE NOT BEEN

SUBSTANTIALLY DISTURBED. THE PERSON(S) OR FIRM(S) MUST BE

IMMEDIATELY DIRECTED TO MAKE ANY NECESSARY REPAIRS.

5. ANY SEDIMENT BUILT UP MUST BE REMOVED AND PLACED IN THE

DESIGNATED SPOIL DISPOSAL SITE.

6. TEMPORARY SEEDING AND MULCHING MUST BE PERFORMED AS

REQUIRED TO PREVENT EROSION ON SLOPES OR ALONG DRAINAGE

DITCHES. LOCATIONS MUST BE APPROVED BY THE CONTRACTING

OFFICER PRIOR TO PLACEMENT.

B. PERMANENT EROSION CONTROL:

1. ALL DISTURBED AREAS MUST BE RESTORED AS NOTED BELOW AND

DIRECTED IN THE PLANS AND SPECIFICATIONS FOR TOPSOIL, AND

SEEDING.

2. UPON COMPLETION OF CONSTRUCTION, SEED OR INSTALL SOD AT

LOCATIONS SHOWN ON THE PLANS.

3. THE SEEDING FOR EROSION CONTROL MUST BE IN ACCORDANCE WITH

SPECIFICATION 32 92 19 AND AS UPDATED BY SPECIAL PROVISION.

C. OFF-SITE DISPOSAL - THE CONTRACTOR MUST NOT DISPOSE OF SURPLUS

EXCAVATED MATERIAL FROM THE SITE WITHOUT NOTIFYING THE

CONTRACTING OFFICER AT LEAST 48 HOURS PRIOR TO THE REMOVAL. THIS

NOTIFICATION MUST INCLUDE THE DISPOSAL LOCATION.

D. EROSION CONTROLS TO BE AS SHOWN ON THE DRAWINGS AND AS

OUTLINED IN TECHNICAL SPECIFICATION 01 57 19 AND AS UPDATED BY

SPECIAL PROVISION.

E. PLACE AND MAINTAIN FILTER FABRIC FENCE, ADJUSTING THE FENCE AS

NECESSARY TO ACCOMMODATE CONSTRUCTION ACTIVITIES. NO SEPARATE

PAY FOR RELOCATING OR MAINTAINING FENCE. LOCATION OF ALL FILTER

FABRIC FENCE TO BE APPROVED BY THE CONTRACTING OFFICER.

F. PROVIDE AND MAINTAIN FILTER FABRIC FENCE AND ROCK DAM, AS

APPROPRIATE, FOR EROSION CONTROL.

G. A VACUUM SWEEPER CAPABLE OF CONTAINING ALL SWEPT DEBRIS MUST BE

REQUIRED TO BE ON-SITE AT ALL TIMES DURING CONSTRUCTION ACTIVITIES.

CONTRACTOR IS FULLY RESPONSIBLE TO PROVIDE THE NECESSARY

MEASURES FOR DUST AND DEBRIS CONTROL.

A. VERIFY THE LOCATION AND DEPTH OF ALL EXISTING UTILITIES WITHIN THE

PROJECT LIMITS, STAGING AND HAUL ROUTE AREAS PRIOR TO COMMENCING

WORK.

B. MINIMIZE THE SITE DISTURBANCE INCLUDING RUTS PRODUCED BY VEHICLES

AND EQUIPMENT WITHIN ALL CONSTRUCTION AREAS.

C. RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES OR ROADS

REGARDLESS OF LEGAL LOAD. REPAIRS MUST BE MADE AT NO ADDITIONAL

COST TO THE AIRPORT.

D. OBTAIN APPROVAL FROM THE AIRPORT AND CONTRACTING OFFICER PRIOR

TO ESTABLISHING CONSTRUCTION ACCESS ROADS. EXISTING ROADS MUST

BE USED TO THE MAXIMUM EXTENT POSSIBLE.

E. PROVIDE MATERIAL SUBMITTALS FOR THE CONTRACTING OFFICER'S REVIEW

PRIOR TO ORDERING.

F. ALL UNPAVED AREAS OUTSIDE THE CONTRACT WORK LIMITS, INCLUDING

STAGING AREAS WHICH ARE DISTURBED BY MUST BE REPAIRED AND

RESEEDED, IF REQUIRED. NO ADDITIONAL DIRECT COST MUST BE MADE FOR

THESE REPAIRS, BUT RATHER MUST BE CONSIDERED INCIDENTAL TO OTHER

ITEMS OF WORK.

G. OBTAIN ALL DEVELOPMENT AND CONSTRUCTION PERMITS REQUIRED AT THE

CONTRACTOR'S EXPENSE PRIOR TO COMMENCEMENT OF WORK.

H. CONSTRUCTION LIMITS - ALL CONTRACTOR VEHICLES AND TRAFFIC ARE TO

REMAIN WITHIN THE LIMITS OF THE CONSTRUCTION AREA, STAGING AREA,

OR HAUL ROUTES AS SHOWN ON THE PLANS.

I. REVIEW ALL AIRFIELD UTILITIES AND FAA UTILITIES WITH THE AIRPORT

STAFF, FAA STAFF AND CONTRACTING OFFICER PRIOR TO BEGINNING WORK.

LOCATION OF FAA CABLES MUST BE VERIFIED AND FLAGGED PRIOR TO

EXCAVATION AND EMBANKMENT OPERATIONS. CONTRACTOR MUST BE

RESPONSIBLE TO MAINTAIN THE MARKING OF THE CABLE FOR THE

DURATION OF THE PROJECT.

J. COMPLY WITH ALL LOCAL AIR QUALITY REGULATIONS WHICH PERTAIN TO

CONSTRUCTION ACTIVITIES AND/OR PLANT OPERATIONS.

K. STAGING AREA - THE CONTRACTOR'S STAGING AREA IS SHOWN ON SHEET

GC100. THE CONTRACTOR IS TO MAKE PROVISIONS FOR ANY REQUIRED

UTILITIES. THE CONTRACTOR IS TO PROVIDE A SECURITY FENCE AROUND

UTILIZED STAGING AREAS. UPON COMPLETION OF THIS PROJECT THE

CONTRACTOR IS TO RESTORE AND RE-GRADE THE STAGING AREA:

INCLUDING, BUT NOT LIMITED TO THE REMOVAL OF FENCING, UTILITIES,

RESTORING TOPSOIL AND RESEEDING COMPLETELY TO THE SATISFACTION

OF THE CONTRACTIC OFFICER. THERE WILL BE NO SEPARATE PAY FOR

WORK ASSOCIATED WITH ESTABLISHING AND RESTORING CONTRACTOR

STAGING AREA.

L. AREAS OF STOCKPILED MATERIALS WITHIN THE CONSTRUCTION AREA ARE

TO BE TREATED IN SUCH A MANNER AS TO PREVENT MOVEMENT OR

EROSION RESULTING FROM AIRCRAFT BLAST, WIND CONDITIONS OR

RAINFALL. CONTRACTOR IS TO SWEEP, ON A DAILY BASIS, ROADWAYS THAT

ARE ALONG HIS HAUL ROUTES AND IMMEDIATELY CLEAN UP MUD THAT

FALLS ON PAVEMENT OUTSIDE OF HIS LIMITS OF CONSTRUCTION AS A

RESULT OF HIS CONSTRUCTION OR HAULING ACTIVITIES. CERTAIN AREAS

WITHIN THE PROJECT LIMITS ARE NOT AVAILABLE FOR MATERIAL STOCKPILE.

IF NECESSARY, CONTRACTOR IS TO STOCKPILE EMBANKMENT MATERIAL AT

THE LOCATION APPROVED BY THE CONTRACTING OFFICER

M. PROVIDE A MINIMUM 30-DAY NOTICE TO CPA AIRFIELD LIGHTING INSPECTOR

FOR ANY MODIFICATION AND/OR INSPECTION REQUIREMENTS.

P. PROVIDE AN AIRFIELD CERTIFIED SAFETY REPRESENTATIVE TO WALK THE

SITE WITH THE AOA AT 0600.

Q. PERFORM A FOD CHECK ON ANY OF THEIR VEHICLES/EQUIPMENT WHEN

CROSSING A RUNWAY OR TAXIWAY AND REMOVE ANY POTENTIAL FOD FROM

THEIR VEHICLE/EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR ANY

DAMAGE BECAUSE OF NOT COMPLYING WITH THIS REQUIREMENT AND ANY

ASSOCIATED TIME DELAY.

R. REFER TO SHEETS G-101 THROUGH G-111 FOR ADDITIONAL PAVEMENT

MARKING REQUIREMENTS.

A. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL OF THE

WORK SHOWN IN EACH DISCIPLINE. THE WORK SHOWN IS WITHOUT

CONSIDERATION OF A CONSTRUCTION SEQUENCE.

B. THE CONTRACTOR WILL BE REQUIRED TO COORDINATE CONSTRUCTION

ACTIVITIES WITH AIRPORT OPERATIONS AND CONTRACTING OFFICER.

C. MAINTAIN ALL-WEATHER ACCESS TO FAA NAVAID EQUIPMENT THAT IS

WITHIN AND ADJACENT TO THE PROJECT LIMITS AT ALL TIMES.

UTILITY NOTES

A. TAKE CARE TO PROTECT EXISTING UTILITIES FROM DAMAGE RESULTING

FROM GRADING. DAMAGE TO EXISTING UTILITIES TO REMAIN, WHICH ARE A

RESULT OF THE CONTRACTOR'S WORK, ARE TO BE EXPEDITIOUSLY

REPAIRED AT NO ADDITIONAL COST TO THE OWNER. NOTIFY THE

CONTRACTING OFFICER IMMEDIATELY IF DAMAGE TO EXISTING FACILITY

OCCURS.

SAFETY REQUIREMENTS

THE FOLLOWING SAFETY AND OPERATIONAL PRACTICES SHOULD BE OBSERVED.

A. CONDUCT "TAILGATE" SAFETY MEETINGS PRIOR TO EACH SHIFT.

OPERATIONAL SAFETY SHOULD BE A STANDING AGENDA ITEMS DURING

PROGRESS MEETINGS THROUGHOUT THE CONSTRUCTION PROJECT.

B. THE CONTRACTOR, CONTRACTING OFFICER AND AIRPORT MUST PERFORM

ONSITE SAFETY INSPECTIONS THROUGHOUT THE PROJECT, WITH IMMEDIATE

REMEDY OF ANY DEFICIENCIES, WHETHER CAUSED BY NEGLIGENCE,

OVERSIGHT OR PROJECT SCOPE CHANGE.

C. AIRPORT RUNWAYS AND TAXIWAYS MUST REMAIN IN USE BY AIRCRAFT TO

THE MAXIMUM EXTENT POSSIBLE. REFER TO THE CONSTRUCTION STAGING

PHASING PLAN (CSPP).

D. CONTRACTORS AND SUPPLIER EMPLOYEES OR ANY UNAUTHORIZED

PERSONS MUST BE RESTRICTED FROM ENTERING AN AIRPORT OPERATIONS

AREA (AOA) WHERE NOT AUTHORIZED OR NECESSARY TO ENTER.

E. THE ENGINEER, AIRPORT, CONTRACTING OFFICER OR OTHER DESIGNATED

AIRPORT REPRESENTATIVE MAY ORDER THE CONTRACTOR TO SUSPEND

OPERATIONS, MOVE PERSONNEL, EQUIPMENT AND MATERIALS TO A SAFE

LOCATION, BARRICADE ANY OPEN TRENCHES AND STAND BY UNTIL

OPERATIONS ARE APPROVED TO RESUME.

CONSTRUCTION MAINTENANCE AND FACILITIES

MAINTENANCE

BEFORE BEGINNING ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR MUST,

THROUGH THE AIRPORT, GIVE THE NOTICE TO AIRMEN (NOTAM) SYSTEM OF

LOCATION, TIME AND DATE OF COMMENCEMENT OF CONSTRUCTION. UPON

COMPLETION OF WORK AND RETURN OF ALL SUCH AREAS TO STANDARD

CONDITIONS, THE CONTRACTOR MUST, THROUGH THE AIRPORT, VERIFY THE

CANCELLATION OF ALL NOTICES ISSUED VIA THE NOTAM SYSTEM. THROUGHOUT

THE DURATION OF THE CONSTRUCTION PROJECT, THE CONTRACTOR MUST:

A. BE AWARE OF AND UNDERSTAND THE SAFETY REQUIREMENTS AS

DESCRIBED IN AC 150/5370-2 OPERATIONAL SAFETY ON AIRPORTS DURING

CONSTRUCTION.

B. CONDUCT ACTIVITIES SO AS NOT TO VIOLATE ANY SAFETY STANDARDS

CONTAINED IN AC 150/5370-2 OR ANY OF THE REFERENCES THEREIN.

C. INSPECT ALL CONSTRUCTION AND STORAGE AREAS AS OFTEN AS

NECESSARY TO BE AWARE OF CONDITIONS.

D. PROMPTLY TAKE ALL ACTIONS NECESSARY TO PREVENT OR REMEDY ANY

UNSAFE OR POTENTIALLY UNSAFE CONDITIONS AS SOON AS THEY ARE

DISCOVERED.

RUNWAY SAFETY AREA (RSA) AND TAXIWAY

OBJECT FREE AREA (TOFA)

LIMIT CONSTRUCTION TO OUTSIDE OF THE RSA AND TOFA, UNLESS THE RUNWAY

OR TAXIWAY IS CLOSED (SEE AC 150/5370-2).

A. PROCEDURES FOR PROTECTING RUNWAY EDGES:

1. LIMIT CONSTRUCTION TO NO CLOSER THAN 250 FEET FROM THE

RUNWAY CENTERLINE, UNLESS THE RUNWAY IS CLOSED OR

RESTRICTED TO AIRCRAFT OPERATIONS REQUIRING A LESSER

STANDARD RSA THAT IS EQUAL TO THE RSA AVAILABLE DURING

CONSTRUCTION.

2. PREVENT PERSONNEL, MATERIAL, AND/OR EQUIPMENT, AS DEFINED IN

AC 150/5300-13A, PARAGRAPH 306, "OBSTACLE FREE ZONE (OFZ)," FROM

PENETRATING THE OFZ WHILE THE TAXIWAYS AND RUNWAY ARE

OPERATIONAL.

3. COORDINATE CONSTRUCTION ACTIVITY WITH THE AIRPORT AND THE

CONTRACTING OFFICER TO ISSUE AN APPROPRIATE NOTAM.

AIRPORT CONSTRUCTION SAFETY INFORMATION:

RUNWAY SAFETY AREA - 250' (77 meters) FROM CENTERLINE OF RUNWAY 08-26.

RUNWAY OBJECT FREE AREA - 400' (122 meters) FROM CENTERLINE OF RUNWAYS 08-26

TAXIWAY OBJECT FREE AREA - 193' (59 meters) FROM CENTERLINE OF ANY

TAXIWAY.

COORDINATION NOTES

EROSION / SEDIMENTATION CONTROL NOTES

CLOSED RUNWAY WARNINGS AND LIGHTING

A. CLOSED RUNWAY LIGHTED X'S WILL BE REQUIRED FOR THIS PROJECT. THE

USE OF PORTABLE X'S IS ADVISED. THIS WILL DEPEND ON IF THE RUNWAY IS

CLOSED DURING CONSTRUCTION OR A PORTION OF CONSTRUCTION.

B. HAZARDOUS AREA MARKING AND LIGHTING: HAZARDOUS AREAS ON THE

MOVEMENT AREA MUST BE MARKED WITH BARRICADES. THE BARRICADES

RESTRICT ACCESS AND MAKE HAZARDS OBVIOUS TO AIRCRAFT PERSONNEL

AND VEHICLES DURING PERIODS OF LOW VISIBILITY AND AT NIGHT. IDENTIFY

HAZARDOUS AREAS WITH RED FLASHING LIGHTS, THE HAZARDOUS AREA

MARKING AND LIGHTING WILL BE SUPPLIED BY THE CONTRACTOR AS

DEPICTED ON THE PLANS.

TEMPORARY LIGHTING, MARKING AND

SIGNAGE

TEMPORARY LIGHTING, MARKING, AND SIGNAGE IS REQUIRED FOR THIS

PROJECT.

VEHICLE OPERATIONS, MARKINGS AND

CONTROL

A. WHEN ANY VEHICLE OTHER THAN ONE THAT HAS PRIOR APPROVAL FROM

THE AIRPORT MUST TRAVEL OVER ANY PORTION OF AN AIRCRAFT

MOVEMENT AREA IT WILL BE ESCORTED AND PROPERLY IDENTIFIED TO

OPERATE IN THOSE AREAS DURING DAYLIGHT HOURS. THE VEHICLE MUST

HAVE A FLAG OR BEACON ATTACHED TO IT. ANY VEHICLE OPERATING ON

THE MOVEMENT AREAS DURING THE HOURS OF DARKNESS OR REDUCED

VISIBILITY MUST BE EQUIPPED WITH A FLASHING DOME-TYPE LIGHT, THE

COLOR OF WHICH IS IN ACCORDANCE WITH ADVISORY CIRCULAR AC

150/5210-5.

B. IT MAY BE DESIRABLE TO CLEARLY IDENTIFY THE VEHICLES FOR CONTROL

PURPOSES BY EITHER ASSIGNED INITIALS OR NUMBERS THAT ARE

PROMINENT SHOULD BE A MINIMUM 8-INCH BLOCK-TYPE CHARACTERS OF A

CONTRASTING COLOR AND EASY TO READ. THEY MAY BE APPLIED EITHER BY

USING TAPE OR A WATER-SOLUBLE PAINT TO FACILITATE REMOVAL.

MAGNETIC SIGNS ARE ALSO ACCEPTABLE.

C. ACCESS TO THE JOB SITE MUST BE AS SHOWN ON THESE PLANS OR

DESIGNATED BY THE CONTRACTING OFFICER OR AIRPORT.

ADDITIONAL LIMITATIONS ON CONSTRUCTION INCLUDE:

A. PROHIBITING OPEN-FLAME WELDING OR TORCH CUTTING OPERATIONS

UNLESS ADEQUATE FIRE SAFETY PRECAUTIONS ARE PROVIDED AND THESE

OPERATIONS HAVE BEEN AUTHORIZED BY THE AIRPORT OPERATOR (AS

TAILORED TO CONFORM TO LOCAL REQUIREMENTS AND RESTRICTIONS).

B. PROMINENTLY MARKING OPEN TRENCHES, EXCAVATIONS AND STOCKPILED

MATERIALS AND LIGHTING THESE OBSTACLES DURING HOURS OF

RESTRICTED VISIBILITY AND DARKNESS.

C. MARKING AND LIGHTING CLOSED, DECEPTIVE AND HAZARDOUS AREAS ON

AIRPORTS, AS APPROPRIATE.

LIMITATIONS ON CONSTRUCTION

VEHICULAR TRAFFIC LOCATED IN OR CROSSING AN ACTIVE MOVEMENT AREA

MUST HAVE A WORKING TWO-WAY RADIO IN CONTACT WITH THE AIRPORT AND

THE CONTRACTING OFFICER OR BE ESCORTED BY A PERSON IN RADIO CONTACT.

THE CONTRACTOR MUST BE RESPONSIBLE FOR OBTAINING A SUFFICIENT

NUMBER OF AIRPORT COMPATIBLE RADIOS FOR THIS WORK AND SUPPLYING THE

FUNCTIONING RADIOS ON SITE PRIOR TO WORKING IN ANY CONTROLLED

AIRFIELD AREAS. THE DRIVER, THROUGH PERSONAL OBSERVATION, SHOULD

CONFIRM THAT NO AIRCRAFT IS APPROACHING THE VEHICLE POSITION.

CONSTRUCTION PERSONNEL MAY OPERATE IN A MOVEMENT AREA WITHOUT

TWO-WAY RADIO COMMUNICATION PROVIDED A NOTAM IS ISSUED CLOSING THE

AREA AND THE AREA IS PROPERLY MARKED TO PREVENT INCURSIONS.

TWO-WAY RADIO COMMUNICATIONS ARE REQUIRED BETWEEN CONTRACTOR,

AIRPORT AND THE CONTRACTING OFFICER. CONTINUOUS MONITORING IS

REQUIRED ONLY WHEN EQUIPMENT MOVEMENT IS NECESSARY IN CERTAIN

AREAS.

COMMON TRAFFIC ADVISORY FREQUENCY - MONITOR 123.6 MHZ

CONTRACTOR IS REQUIRED TO NOTIFY THE AIRPORT AND CONTRACTING

OFFICER PRIOR TO ENTERING ANY ACTIVE SAFETY AREA.

RADIO COMMUNICATIONS

WASTE AND LOOSE MATERIAL MUST NOT BE PLACED IN ACTIVE MOVEMENT

AREAS. MATERIALS TRACKED ONTO THESE AREAS MUST BE REMOVED

CONTINUOUSLY DURING THE WORK PROJECT. THE CONTRACTOR IS ADVISED

THAT DUST CONTROL, CLEANUP OF ACTIVE PAVEMENT TRACKING DEBRIS ONTO

ACTIVE PAVEMENT AND GENERAL JOBSITE CLEANLINESS IS A SERIOUS SAFETY

CONCERN DURING AIRPORT OPERATIONAL HOURS. FOREIGN OBJECT DEBRIS

(FOD) IS CONSIDERED ANY ITEM THAT COULD POSSIBLY IMPACT THE MOVING

AIRCRAFT. SPECIFIC ITEMS OF CONCERN INCLUDE, BUT ARE NOT LIMITED TO;

ANY PACKAGING FROM MATERIAL INSTALLATION, GRAVEL LEFT ON ACTIVE

PAVEMENTS, DUST TRACKED ONTO ACTIVE PAVEMENTS, HAND TOOLS, DROPPED

HARDWARE, ETC.

DEBRIS

ADHERE TO AIRPORT SECURITY REQUIREMENTS AT ALL TIMES. SECURE

IDENTIFICATION DISPLAY AREA (SIDA) REQUIREMENTS AND RELATED AIRPORT

FAMILIARIZATION REQUIREMENTS ARE MANDATORY. ANY GATE UTILIZED FOR

CONSTRUCTION PURPOSES MUST BE GUARDED BY CONTRACTOR SUPPLIED

SIDA BADGED PERSONNEL OR LOCKED AT ALL TIMES.

AIRPORT SECURITY

RUNWAY OBJECT FREE AREA

A. NO EQUIPMENT STOCKPILES, ETC. MAY BE STORED WITHIN THE

OBJECT FREE AREA ACTIVE PAVEMENTS.

B. PROVIDE A MINIMUM 30-DAY NOTICE TO CPA AIRFIELD LIGHTING

INSPECTOR FOR ANY MODIFICATION AND/OR INSPECTION

REQUIREMENTS.

C. PROVIDE AN AIRFIELD CERTIFIED SAFETY REPRESENTATIVE TO

WALK THE SITE WITH THE AOA AT 0600.

D. PERFORM A FOD CHECK ON ANY OF THEIR VEHICLES /

EQUIPMENT WHEN CROSSING A RUNWAY OR TAXIWAY AND

REMOVE ANY POTENTIAL FOD FROM THEIR VEHICLE / EQUIPMENT

E. RESPONSIBLE FOR ANY DAMAGE BECAUSE OF NOT COMPLYING

WITH THIS REQUIREMENT AND ASSOCIATED TIME DELAY.

ALL VEHICLE OPERATORS HAVING ACCESS TO THE MOVEMENT AREA MUST

ATTEND AND PASS AIRPORT PROVIDED VEHICLE MOVEMENT TRAINING TO

BECOME FAMILIAR WITH AIRPORT PROCEDURES FOR THE OPERATION OF

GROUND VEHICLES AND CONSEQUENCES OF NON-COMPLIANCE.

D.

G

EN

ER

AL

N O

TE

S

17230790

09/24/2021

X

N 79° 04' 50" E 3,326.506

N89°39'58"W155.923M

N

°2 0'

"E

9.

6M

N 10°55'23"W 170.657M

S79°24'52"W 1,074.858M

S10°32'55"E 167.978M

S79°27'05"W

160.979MS10°32'55"E

143.981M

N79°24'52"E 410.946M

S10°52'55"E 211.972M

S79°24'52"W 2,135.728M

N 10°32'55"W

350.937M 114

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

SCALE

OVERALL DEMOLITION PLANA1 1:4000

CD100

O

VE

R

AL

L D

EM

O

LI

TI

O N

P

LA

N

DEMOLITION PLAN GENERAL NOTES

A ALL EXISTING IMPROVEMENTS NOT SHOWN TO BE

REMOVED ON THIS SHEET MUST BE PROTECTED IN

PLACE.

FULL DEPTH ASPHALT PAVEMENT TO BE REMOVED

AREA OF TREES TO BE CLEARED AND GRUBBED

KEYNOTES

LEGEND

CONTRACTOR MAY USE THIS AREA TO PLACE SPOILS.

CONTRACTOR MUST CLEAR AND GRUB AREA AND

ENSURE SPOILS ARE CLEAN AND PLACED PER THE

PROJECT SWPPP. SPOILS ARE APPROXIMATELY 213,850

CU. METERS.

POSSIBLE SPOILS AREA

B REFER TO SHEETS CD101 THROUGH CD103 FOR

ADDITIONAL DEMOLITION INFORMATION.

EXISTING PAVEMENT TO BE REMOVED

17230791

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.

LEASE BOUNDARY

C CONTRACTOR MUST CUT A STRAIGHT EDGE ALONG

EXISTING ASPHALT PAVEMENT FOR INSTALLATION OF

NEW PAVEMENT.

S10°32'55"E 167.978M

S79°27'05"W 160.979M

S10°32'55"E 143.981M

N79°24'52"E 410.946M

S79°24'52"W 2,135.728M

N 10°32'55"W

350.937M

N:1659156.146 E:351493.433

N:1659230.144 E:351896.954

N:1659215.129 E:351482.433

N:1659222.069 E:351898.401

N:1659160.452 E:351568.124

TAXIWAY ALPHA

N:1658580.901 E:352050.437

N:1658974.864 E:351527.072

C1

CS505

X X

XXXXXXXXXXX

X X

X X

X X

X X

X X

X X

X

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

A

FULL DEPTH ASPHALT PAVEMENT TO BE REMOVED

ALL EXISTING IMPROVEMENTS NOT SHOWN TO BE

REMOVED ON THIS SHEET MUST BE PROTECTED IN

PLACE.

AREA OF TREES TO BE CLEARED AND GRUBBED

AREA OF TREES TO BE CLEARED AND GRUBBED110

KEYNOTES

LEGEND

DEMOLITION PLAN GENERAL NOTES

EXISTING FENCE TO BE REMOVED ONLY AFTER THE

NEW PERMANENT FENCE HAS BEEN INSPECTED AND

APPROVED BY CPA. FENCE FABRIC AND POSTS TO BE

SALVAGED BY THE CONTRACTOR AND DELIVERED TO

DESIGNATED SITE IDENTIFIED BY CPA ON CPA

PROPERTY.

EXISTING PAVEMENT TO BE REMOVED

EXISTING PAVEMENT TO BE REMOVED118

EDGE MARKING TO BE REMOVED119

REFER TO SHEET CD103 FOR OFFSITE DEMOLITION PLAN120

B CONTRACTOR MUST CUT A STRAIGHT EDGE ALONG

EXISTING ASPHALT PAVEMENT FOR INSTALLATION OF

NEW PAVEMENT.

LEASE BOUNDARY

MARKING TO BE REMOVED113

CD101

D

EM

O

LI

TI

O

N P

LA

N

17230792

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.SCALE

DEMOLITION PLANA1 1:2000

N89°39'58"W155.923M

N

°2 0'

"E

9.

6M

N 10°55'23"W 170.657M

S79°24'52"W 1,074.858M

S10°52'55"E 211.972M

N:1659163.362 E:352239.826

N:1659154.638 E:352115.013

N:1659266.349 E:352094.383

N:1659068.610 E:352269.741

N:1659077.386 E:352268.107

N:1659082.037 E:352252.973

A3

CD102

A4

CS505

S79°24'52"W 2,135.728M

N79°24'52"E 410.946M

N:1658784.100 E:352194.702

N:1658796.598 E:352260.832

N:1658842.650 E:352184.187

N:1658791.883 E:352193.253

N:1658791.583 E:352193.309

N:1658783.181 E:352148.287

N:1658803.948 E:352259.462

N:1658805.121 E:352265.732

N:1658839.027 E:352184.862

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

A ALL EXISTING IMPROVEMENTS NOT SHOWN TO BE

REMOVED MUST BE PROTECTED IN PLACE.

B REFER TO ELECTRICAL PLANS FOR OVERHEAD LINE

LOCATION.

KEYNOTES

LEGEND

DEMOLITION PLAN GENERAL NOTES

SHOULDER PAVEMENT TO BE REMOVED

MARKING TO BE REMOVED113

AREA OF TREES TO BE CLEARED AND GRUBBED110

FULL DEPTH ASPHALT PAVEMENT TO BE REMOVED

AREA OF TREES TO BE CLEARED AND GRUBBED

EDGE MARKING TO BE REMOVED119

EXISTING FENCE TO BE REMOVED ONLY AFTER THE

NEW PERMANENT FENCE HAS BEEN INSPECTED AND

APPROVED BY CPA. FENCE FABRIC AND POSTS TO BE

SALVAGED BY THE CONTRACTOR AND DELIVERED TO

DESIGNATED SITE IDENTIFIED BY CPA ON CPA

PROPERTY.

LEASE BOUNDARY

C CONTRACTOR MUST CUT A STRAIGHT EDGE ALONG

EXISTING ASPHALT PAVEMENT FOR INSTALLATION OF

NEW PAVEMENT.

CD102

D

EM

O

LI

TI

O

N P

LA

N

17230793

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.

SCALE

DEMOLITION PLANA1 1:2000 SCALE

ENLARGED DEMOLITION PLANA3 N.T.S.

S79°24'52"W 2,135.728M

N79°24'52"E 770.604M

N 10°32'55"W

350.937M

4M CENTERED ON

ELECTRICAL OVERHEAD117 N:1659376.567

E:351480.697

X X X X X X X X X X X

XXXXXXXXXXX

X X

X X

X X

A ALL EXISTING IMPROVEMENTS NOT SHOWN TO BE

REMOVED MUST BE PROTECTED IN PLACE.

AREA OF TREES TO BE CLEARED AND GRUBBED

AREAS OF TREES TO BE CLEARED AND GRUBBED.

CONTRACTOR TO CLEAR 4M CENTERED ON

ALIGNMENT.

B REFER TO ELECTRICAL PLANS FOR OVERHEAD LINE

LOCATION. COORDINATES SHOWN ARE ALONG THE

CENTERLINE OF THE OVERHEAD LINE ALIGNMENT.

ADJUSTMENT IS ALLOWED IN THE ALIGNMENT BASED

ON FIELD CONDITIONS WITH THE APPROVAL OF THE

CONTRACTING OFFICER.

KEYNOTES

LEGEND

DEMOLITION PLAN GENERAL NOTES

SCALE

OFFSITE DEMOLITION PLANA1 1:2000

CD103

O

FF

SI

TE

D

EM

O

LI

TI

O

N P

LA

N

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

17230794

NORTH

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

SCALE

OVERALL SITE PLAN - ALL PHASESA1 1:8000

CS100

SITE PLAN GENERAL NOTES

REFER TO SHEETS CS101 - CS106, CS131 FOR FENCE

LOCATION.

CHAIN LINK FENCE, RE: CS506 AND CS507

ASPHALT SHOULDER, RE: D1/CS500

CONCRETE PAVEMENT, RE: D3/CS500

B REFER TO SHEETS CS104, CS105, CS120 - CS123 FOR

GRAVEL ROADWAY.

REFER TO SHEETS CS131 - CS136 FOR TAXIWAY PLAN &

PROFILE.

D REFER TO SHEETS CS137 AND CS138 FOR TAXIWAY

PLAN AREAS S1, S2, S3, AND S4.

A

X

ASPHALT ROADWAY, RE: C1/CS500

C

GRAVEL ROAD, RE: A3/CS500

F REFER TO ELECTRICAL DRAWINGS FOR ALL SITE

LIGHTING INFORMATION.

KEYNOTES

LEGEND

CHAIN LINK FENCE WITH CONCRETE MOW STRIP

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

ASPHALT APRON PAVEMENT

RE: B3/CS500

ASPHALT TAXIWAY PAVEMENT

RE: C3/CS500

LEASE BOUNDARY

RUNWAY OBJECT FREE AREA

PROJECT LIMITS FOR P-9010

O

VE

R

AL

L

SI

TE

P

LA

N

AL

L

PH

AS

ES

17230795

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

CS101

SITE PLAN GENERAL NOTES

REFER TO SHEETS CS101 - CS106, CS131 FOR FENCE

LOCATION.

CHAIN LINK FENCE, RE: CS506 AND CS507

ASPHALT SHOULDER, RE: D1/CS500

CONCRETE PAVEMENT, RE: D3/CS500

B REFER TO SHEETS CS104, CS105, CS120 - CS123 FOR

GRAVEL ROADWAY.

REFER TO SHEETS CS131 - CS136 FOR TAXIWAY PLAN &

PROFILE.

D REFER TO SHEETS CS137 AND CS138 FOR TAXIWAY

PLAN AREAS S1, S2, S3, AND S4.

A

X

ASPHALT ROADWAY, RE: C1/CS500

C

GRAVEL ROAD, RE: A3/CS500

F REFER TO ELECTRICAL DRAWINGS FOR ALL SITE

LIGHTING INFORMATION.

KEYNOTES

LEGEND

CHAIN LINK FENCE WITH CONCRETE MOW STRIP

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

ASPHALT APRON PAVEMENT

RE: B3/CS500

ASPHALT TAXIWAY PAVEMENT

RE: C3/CS500

LEASE BOUNDARY

RUNWAY SAFETY AREARSA

O

VE

R

AL

L

SI

TE

P

LA

N

A N

D P

AV

EM

EN

T

M

AR

KI

N

G P

LA

N

17230796

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

CHAIN LINK FENCE, RE: CS506 & CS507

A

BUILDING

B

REFER TO SHEETS CS201 AND CS202 FOR ROADWAY

PROFILES.

ASPHALT ROADWAY, RE: C1/CS500

C

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

X

D

REFER TO ELECTRICAL DRAWINGS FOR ALL SITE

LIGHTING INFORMATION.

REFER TO ARCHITECTURAL DRAWINGS FOR EXACT

BUILDING DIMENSIONS AND SPECIFICATIONS.

LEGEND

SITE PLAN GENERAL NOTES

POWER POLE, RE: ES101

FIRE HYDRANT

KEYNOTES

WATER PUMP HOUSE, RE: AE101

201 WATER STORAGE TANK, RE: D-301

CHAIN LINK FENCE, RE: CS506 AND CS507

222 SIDEWALK, RE: B3/CS501

223 TRANSFORMER PAD, RE: ES101

226 SWITCHGEAR PAD, RE: ES101

227 WALL MOUNTED FDC, RE: F-102

228 TYPE 3 BARRICADE, RE: A4/CS501

214 FIRE WATER STORAGE TANKS, RE: F-111

215 HYDROPNEUMATIC TANK, RE: D-301

X CHAIN LINK FENCE WITH CONCRETE MOW

STRIP, RE: CS506 & CS507

CONCRETE SIDEWALK, RE: B3/CS501

E

REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

DOUBLE SWING GATE, RE: C2/CS507204

SCALE

SITE PLAN - AREA 1A1 1:400

CS102

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

SI

TE

P

LA

N

AR

EA

17230797

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

BIO SECURITY CONTAINMENT FACILITY, RE: A1/CS510

204 DOUBLE SWING GATE, RE: C2/CS507

ASPHALT SHOULDER, RE: D1/CS500

B

REFER TO SHEETS CS201 AND CS202 FOR ROADWAY

PROFILES.

ASPHALT ROADWAY, RE: C1/CS500

C

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

X

CHAIN LINK FENCE, RE: CS506 AND CS507

E

REFER TO ELECTRICAL DRAWINGS FOR ALL SITE

LIGHTING INFORMATION.

224 AIRFIELD LIGHTING VAULT, RE: ES103

KEYNOTES

LEGEND

SITE PLAN GENERAL NOTES

LIGHT POLES, RE: ELECTRICAL DRAWINGS

FIRE HYDRANT

REFER TO DETAIL A1 AND B1 ON SHEET CS500 FOR

APRON PAVEMENT SECTIONS.

229 AIRCRAFT TIEDOWN, RE: B4/CS505 AND A4/CS509

AIRCRAFT TIEDOWN, RE: A4/CS509

APRON/TAXIWAY LIGHTS

APRON/TAXIWAY LIGHTS208

STORM DRAIN MANHOLE, RE: A1/CG500

CATCH BASIN, RE: B4/CG500

D

CB

HEADWALL, RE: A3/CG501

X

CHAIN LINK FENCE, RE: CS506 & CS507

CHAIN LINK FENCE WITH CONCRETE MOW

STRIP, RE: CS506 & CS507

D

REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

CONCRETE PAVEMENT, RE: D3/CS500

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

HEAVY DUTY CONCRETE PAVEMENT, RE: A4/CS500

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

SCALE

SITE PLAN - AREA 2A1 1:400

CS103

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

SI

TE

P

LA

N

AR

EA

17230798

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

ASPHALT SHOULDER, RE: D1/CS500

B

REFER TO SHEETS CS201 AND CS202 FOR ROADWAY

PROFILES.

C

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

X

CHAIN LINK FENCE, RE: CS506 AND CS507

E

REFER TO ELECTRICAL DRAWINGS FOR ALL SITE

LIGHTING INFORMATION.

KEYNOTES

LEGEND

SITE PLAN GENERAL NOTES

REFER TO DETAIL A1 AND B1 ON SHEET CS500 FOR

APRON PAVEMENT SECTIONS.

229 AIRCRAFT TIEDOWN, RE: B4/CS505 AND A4/CS509

LIGHT POLES, RE: ELECTRICAL DRAWINGS

FIRE HYDRANT

AIRCRAFT TIEDOWN, RE: A4/CS509

APRON/TAXIWAY LIGHTS

APRON/TAXIWAY LIGHTS208

LEASE BOUNDARY

CHAIN LINK FENCE WITH CONCRETE MOW

STRIP, RE: CS506 & CS507

D

REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

CONCRETE PAVEMENT, RE: D3/CS500

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

SCALE

SITE PLAN - AREA 3A4 1:400

CS104

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

SI

TE

P

LA

N

AR

EA

17230799

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

A REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

X

CHAIN LINK FENCE, RE: CS506 AND CS507

KEYNOTES

LEGEND

SITE PLAN GENERAL NOTES

LEASE BOUNDARY

CHAIN LINK FENCE WITH CONCRETE MOW

STRIP, RE: CS506 & CS507

B TEST SECTION MAY BE SHIFTED WITHIN THE AREA

IDENTIFIED BASED ON FIELD CONDITIONS AND

ADJACENT PROJECT ACTIVITY. OBTAIN APPROVAL ON

FINAL LOCATION FROM CONTRACTING OFFICER.

250 AREA FOR PAVEMENT TEST SECTION

SCALE

SITE PLAN - AREA 4A1 1:400

CS105

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

SI

TE

P

LA

N

AR

EA

17230800

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

X

CHAIN LINK FENCE, RE: CS506 AND CS507

KEYNOTES

LEGEND

SITE PLAN GENERAL NOTES

EXISTING FENCEX

LEASE BOUNDARY

CHAIN LINK FENCE WITH CONCRETE MOW

STRIP, RE: CS506 & CS507

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

SCALE

SITE PLAN - AREA 5A1 1:400

CS106

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

SI

TE

P

LA

N

AR

EA

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.

17230801

TAXIWAY PLAN AND PROFILE

GENERAL NOTES

B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

KEYNOTES

LEGEND

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

STORM DRAIN MANHOLE, RE: A1/CG500D

ASPHALT TAXIWAY PAVEMENT

RE: C3/CS500

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

TAXIWAY END LIGHTS, RE: ELECTRICAL DRAWINGS

ELEVATED RETROREFLECTIVE MARKER,

RE: ELECTRICAL DRAWINGS

ASPHALT APRON PAVEMENT

RE: B3/CS500

EXISTING CATCH BASIN, RE: B4/CG500CB

CS131

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

TAXIWAY PLAN - AREA T1C1 1:400

VERTICAL SCALE

HORIZONTAL SCALE

TAXIWAY PROFILE - AREA T1A1

1:80

1:400

TA

XI

W

AY

P

LA

N A

N D

P R

O

FI

LE

AR

EA

T

17230806

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

KEYNOTES

LEGEND

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

ASPHALT TAXIWAY PAVEMENT

RE: C3/CS500

A B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

TAXIWAY PLAN AND PROFILE

GENERAL NOTES

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

ASPHALT APRON PAVEMENT

RE: B3/CS500

CS132

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

TAXIWAY PLAN - AREA T2C1 1:400

VERTICAL SCALE

HORIZONTAL SCALE

TAXIWAY PROFILE - AREA T2A1

1:80

1:400

TA

XI

W

AY

P

LA

N A

N D

P R

O

FI

LE

AR

EA

T

17230807

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

ASPHALT APRON, TAXIWAY PAVEMENT

RE: C3/CS500

A B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

TAXIWAY PLAN AND PROFILE

GENERAL NOTES

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

CS133

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

TAXIWAY PLAN - AREA T3C1 1:400

VERTICAL SCALE

HORIZONTAL SCALE

TAXIWAY PROFILE - AREA T3A1

1:80

1:400

TA

XI

W

AY

P

LA

N A

N D

P R

O

FI

LE

AR

EA

T

17230808

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

ASPHALT APRON, TAXIWAY PAVEMENT

RE: C3/CS500

A B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

TAXIWAY PLAN AND PROFILE

GENERAL NOTES

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

CS134

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

TAXIWAY PLAN - AREA T4C1 1:400

VERTICAL SCALE

HORIZONTAL SCALE

TAXIWAY PROFILE - AREA T4A1

1:80

1:400

TA

XI

W

AY

P

LA

N A

N D

P R

O

FI

LE

AR

EA

T

17230809

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

LEASE BOUNDARY

ASPHALT APRON, TAXIWAY PAVEMENT

RE: C3/CS500

A B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

REFER TO SHEET ES115 FOR ELECTRICAL CONDUIT

INSTALLATION

TAXIWAY PLAN AND PROFILE

GENERAL NOTES

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

RUNWAY SAFETY AREARSA

CS135

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

TAXIWAY PLAN - AREA T5C1 1:400

VERTICAL SCALE

HORIZONTAL SCALE

TAXIWAY PROFILE - AREA T5A1

1:80

1:400

NORTH

TA

XI

W

AY

P

LA

N A

N D

P R

O

FI

LE

AR

EA

T

17230810

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

LEASE BOUNDARY

ASPHALT APRON, TAXIWAY PAVEMENT

RE: C3/CS500

A B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

TAXIWAY PLAN AND PROFILE

GENERAL NOTES

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

REFER TO SHEET ES115 FOR ELECTRICAL CONDUIT

INSTALLATION

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

RUNWAY SAFETY AREARSA

CS136

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

TAXIWAY PLAN - AREA T6C1 1:400

VERTICAL SCALE

HORIZONTAL SCALE

TAXIWAY PROFILE - AREA T6A1

1:80

1:400

NORTH

TA

XI

W

AY

P

LA

N A

N D

P R

O

FI

LE

AR

EA

T

17230811

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

TAXIWAY PLAN GENERAL NOTES

ASPHALT SHOULDER, RE: D1/CS500

APRON/TAXIWAY LIGHTS208

LEASE BOUNDARY

ASPHALT APRON, TAXIWAY PAVEMENT

RE: C3/CS500

A B

REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.

C

REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING

INFORMATION.

D

CONTRACTOR MUST PROVIDE UNPAVED SHOULDER ON

BOTH SIDES OF THE TAXIWAY. REFER TO SHEET CS500

FOR WIDTHS AND SLOPES.

REFER TO SHEET CS504 FOR TAXIWAY PAVEMENT

CROSS SECTIONS.

E REFER TO SHEETS CS141 - CS148 FOR PAVEMENT

MARKING PLANS.

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

REFER TO SHEET ES116 FOR ELECTRICAL CONDUIT

INSTALLATION

F CONTRACTOR MUST NOTE BORINGS 22, 23, AND 32

INDICATE SUBGRADE WILL BE WITHIN SILT. THESE

AREAS WILL REQUIRE OVER EXCAVATION FOR THE

PAVEMENT INSTALLATION. REFER TO SPECIFICATION

30 00 20. 00 20 AND PAVEMENT DETAILS ON CS500.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

EXISTING APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

EXISTING JUNCTION BOX,

RE: ELECTRICAL DRAWINGS

SCALE

TAXIWAY PLAN - AREA S2A1 1:400

CS137

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

AS SHOWN

1581694

FIRE PROTECTION

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

CN

KY

K. YOSHIMOTO

JC

SCALE

TAXIWAY PLAN - AREA S1C1 1:400

AREAS S1 & S2

TA

XI

W

AY

P

LA

N

AR

EA

S S1

S

17230812

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

CHAIN LINK FENCE

BUILDING

X

LEGEND

PAVEMENT MARKING PLAN

GENERAL NOTES

POWER POLE, RE: ES101

FIRE HYDRANT

KEYNOTES

WATER PUMP HOUSE, RE: AE101202

214 FIRE WATER STORAGE TANKS, RE: F-111

245 ROADWAY CENTERLINE STRIPING, RE: C1/CS508

246 ROADWAY EDGE LINE STRIPING, RE: D2/CS508

X CHAIN LINK FENCE WITH CONCRETE MOW STRIP

WATER STORAGE TANK, RE: D-301201

A REFER TO SHEETS CS503 AND CS508 FOR MARKING

DETAILS.

B STATIONING SHOWN IS FOR REFERENCE ONLY.

247 STOP BAR STRIPING, RE: C4/CS508

249 STOP SIGN, RE: A1/CS508

C REFER TO SHEETS G-101 - G-111 FOR ADDITIONAL

PAVEMENT MARKING REQUIREMENTS.

SCALE

PAVEMENT MARKING PLAN - AREA 1A1 1:400

CS141

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

PA

VE

M

EN

T M

AR

KI

N G

P

LA

N

AR

EA

17230896

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

205 TAXIWAY CENTERLINE MARKING, RE: C1/CS503

206 TAXIWAY SHOULDER MARKING (TYP), RE: D3/CS503

207 APRON EDGE MARKING, RE: C2/CS503

X

225 TAXILANE EDGE MARKING, RE: C5/CS503

KEYNOTES

LEGEND

LIGHT POLES, RE: ELECTRICAL DRAWINGS

230 C-5 LABEL AND STOP BAR MARKING, RE: A5,B5/CS503

AIRCRAFT TIEDOWN, RE: A4/CS509

APRON/TAXIWAY LIGHTS, PROTECT LIGHTS FROM PAINT208

STORM DRAIN MANHOLE, RE: A1/CG500

CATCH BASIN, RE: B4/CG500

D

CB

HEADWALL, RE: A3/CG501

245 ROADWAY CENTERLINE STRIPING, RE: C1/CS508

246 ROADWAY EDGE LINE STRIPING, RE: D2/CS508

247 STOP BAR STRIPING, RE: C4/CS508

X

CHAIN LINK FENCE

CHAIN LINK FENCE WITH CONCRETE MOW STRIP

A REFER TO SHEETS CS503 AND CS508 FOR MARKING

DETAILS.

PAVEMENT MARKING PLAN

GENERAL NOTES

BIO SECURITY CONTAINMENT FACILITY, RE: A1/CS510203

B STATIONING SHOWN IS FOR REFERENCE ONLY.

249 STOP SIGN, RE: A1/CS508

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

C REFER TO SHEETS G-101 - G-111 FOR ADDITIONAL

PAVEMENT MARKING REQUIREMENTS.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

FIRE HYDRANT

SCALE

PAVEMENT MARKING PLAN - AREA 2A1 1:400

CS142

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

PA

VE

M

EN

T M

AR

KI

N G

P

LA

N

AR

EA

17230897

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

207 TAXIWAY EDGE MARKING, RE: C2/CS503

X

225 TAXILANE EDGE MARKING, RE: C5/CS503

KEYNOTES

LEGEND

230 C-5 LABEL AND STOP BAR MARKING, RE: A5, B5/CS503

LIGHT POLES, RE: ELECTRICAL DRAWINGS

AIRCRAFT TIEDOWN, RE: A4/CS509

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

APRON/TAXIWAY LIGHTS, PROTECT LIGHTS FROM PAINT208

231 C-17 LABEL AND STOP BAR MARKING, RE: A5, B5/CS503

CHAIN LINK FENCE WITH CONCRETE MOW STRIP

A REFER TO SHEETS CS503 AND CS508 FOR MARKING

DETAILS.

PAVEMENT MARKING PLAN

GENERAL NOTES

LEASE BOUNDARY

B STATIONING SHOWN IS FOR REFERENCE ONLY.

AIRFIELD SIGN, RE: ELECTRICAL DRAWINGS

C REFER TO SHEETS G-101 - G-111 FOR ADDITIONAL

PAVEMENT MARKING REQUIREMENTS.

CATCH BASIN, RE: B4/CG500CB

FIRE HYDRANT

SCALE

PAVEMENT MARKING PLAN - AREA 3A3 1:400

CS143

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

10 SEP 2021

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

KATHYRIYA H. KENNEDY

TX 98244

CN

KY

K. YOSHIMOTO

JC

PA

VE

M

EN

T M

AR

KI

N G

P

LA

N

AR

EA

17230898

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

TAXIWAY CENTERLINE MARKING, RE: C1/CS503

TAXIWAY EDGE MARKING, RE: C2/CS503

X

KEYNOTES

LEGEND

X EXISTING FENCE

APRON/TAXIWAY LIGHTS, PROTECT LIGHTS FROM PAINT208

STORM DRAIN MANHOLE, RE: A1/CG500D

X

CHAIN LINK FENCE

CHAIN LINK FENCE WITH CONCRETE MOW STRIP

A REFER TO SHEETS CS503 AND CS508 FOR MARKING

DETAILS.

PAVEMENT MARKING PLAN

GENERAL NOTES

B STATIONING SHOWN IS FOR REFERENCE ONLY.

C REFER TO SHEETS G-101 - G-111 FOR ADDITIONAL

PAVEMENT MARKING REQUIREMENTS.

APRON/TAXIWAY LIGHTS,

RE: ELECTRICAL DRAWINGS

TAXIWAY END LIGHTS, RE: ELECTRICAL DRAWINGS

ELEVATED RETROREFLECTIVE MARKER,

RE: ELECTRICAL DRAWINGS

CS144

NORTH

KHK SMC JDE

1 2 3 4 5

D

C

B

A

1 2 3 4 5

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE

TI

N

IA

N

IN

TE

R N

AT

IO

N

AL

A

IR

PO

R

T (T

IQ

TI

N

IA

N

, C N

M I

N

AV

FA

C

P

AC

IF

IC

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

M

AK

AL

AP

A, H

AW

AI

I

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AS SHOWN

1581694

FIRE PROTECTION

N

AV

FA

C

P

AC

IF

IC

FI

N

AL

R

E- D

ES

IG

N S

U

BM

IT

TA

L

TEXAS REGISTERED ENGINEERING FIRM F-2966

JACOBS GOVERNMENT SERVICES COMPANY

777 MAIN STREET

FORT WORTH, TEXAS 76102

A/E INFO

D

C

B

A

A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340

JEG NO. WFXO6305

DRAWFORM REVISION: 30 APR 2015

DATE

FY

M C

AF

P

-9

0/

PA

F1

A

PS

I C

AR

G O

P

AD

W

IT

H T

AX

IW

AY

E

XT

EN

SI

O

N

CN

KY

K. YOSHIMOTO

JC

KATHYRIYA H. KENNEDY

98244

SCALE

PAVEMENT MARKING PLAN - AREA T1C1 1:400

PA

VE

M

EN

T M

AR

KI

N G

P

LA

N

AR

EA

S T1

T

17230899

NOTE:

UNLESS OTHERWISE STATED, ALL CIVIL PLAN

SHEETS DIMENSIONS ARE IN METERS.

SCALE

PAVEMENT MARKING PLAN - AREA T2A1 1:400

AREAS T1 & T2

TAXIWAY CENTERLINE MARKING, RE: C1/CS503205

TAXIWAY EDGE MARKING, RE: C2/CS503207

KEYNOTES

LEGEND

APRON/TAXIWAY LIGHTS, PROTECT LIGHTS FROM PAINT208

APRON/TAXIWAY LIGHTS

A REFER TO SHEETS CS503 AND CS508 FOR MARKING

DETAILS.

PAVEMENT MARKING PLAN

GENERAL NOTES

B…