N6274222R1306_AMD04.pdf
PDF 42 MB Posted
- Solicitation number
- N6274222R1306
About this file
This solicitation concerns four construction projects at Tinian International Airport in the Commonwealth of the Northern Mariana Islands. The projects include construction of a cargo pad and taxiway extension, fuel tanks with a receipt pipeline and hydrant system, airfield development of roads, and an optional maintenance support facility. The Navy seeks to award a firm fixed-price contract for the base projects, with three pre-priced planned modifications for munitions and explosives of concern remediation. Offerors must submit responses by the solicitation response date of September 6, 2022. The Navy may exercise the option for the maintenance support facility within 365 days of award. The solicitation specifies design requirements to withstand typhoon winds and seismic activity.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ACQR5898351
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
RFP N62742-22-R-1306
FY19 MCAF P-9030/PAF189030 APSI - CARGO PAD WITH TAXIWAY EXTENSION
FY19 MCAF P-9040/PAF189040 APSI - MAINTENANCE SUPPORT FACILITY
FY20 MCAF P-9010/PAF189010 APSI - FUEL TANKS WITH RECEIPT PIPELINE & HYDRANT SYSTEM
FY20 MCAF P-9021/PAF189021 APSI -AIRFIELD DEVELOPMENT PHASE 1 - ROADS
TINIAN INTERNATIONAL AIRPORT, TINIAN, CNMI
Continued on Page 2
1. CONTRACT ID CODE PAGE OF PAGES
1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 23-Mar-2022
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6274222R1306
X 9B. DATED (SEE ITEM 11)
07-Dec-2021
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
23-Mar-2022
CODE
NAVFAC PACIFIC
CONSTRUCTION CONTRACTS BR (CODE ACQ33)
258 MAKALAPA DR STE 100
PEARL HARBOR HI 96860-3134
N62742 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N6274222R1306
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
The following have been added by full text:
SUMMARY OF CHANGES
PROJECT TABLE OF CONTENTS
Delete the Project Table of Contents in Parts A, B, C, D and E in its entirety and replace it with the attached Table of Contents, Amendment 0004.
SECTION 00 01 15 LIST OF DRAWINGS
PARA 1.2 CONTRACT DRAWINGS
1.2.1 Part B List of Drawings
The following drawings are revised and accompany this Amendment:
NAVFAC
DWG NO.
DRAWING
SHEET NO.
CHANGE
NO.
TITLE
17230858 CU107 1 KEYNOTE TABLE - STRUCTURES
17230896 CU504 1 MISCELLANEOUS DETAILS
17230913 S-004 1 GENERAL NOTES
1.2.3 Part D List of Drawings
The following drawings are revised and accompany this Amendment:
NAVFAC
DWG NO.
DRAWING
SHEET NO.
CHANGE
NO.
TITLE
17256558 CS103 1 SITE PLAN – AREA 3
17256560 CS105 1 SITE PLAN – AREA 5
17256594 CS503 1 SITE DETAILS
17256597 CS506 1 SITE DETAILS
17256600 CG500 1 DRAINAGE DETAILS
17256601 CG501 1 DRAINAGE DETAILS
17256602 CG502 1 DRAINAGE DETAILS
17256697 CF111 1 POL PIPELINE PLAN AND PROFILE 10
17256698 CF112 1 POL PIPELINE PLAN AND PROFILE 11
17256699 CF113 1 POL PIPELINE PLAN AND PROFILE 12
17256700 CF114 1 POL PIPELINE PLAN AND PROFILE 13
17256764 SP502 1 STEEL TANK DETAILS
17256867 E-001 1 GENERAL NOTES & LEGEND
17256873 ES105 1 SITE PLAN – AREA 5
17256881 EP111 1
POWER – HYDRANT SYSTEM FUEL PUMP HOUSE &
TRUCK FILLSTAND
17256882 EP112 1
POWER – SEAPORT FUEL PUMP HOUSE, DIESEL
SERVICE STATION, & GENERATOR BUILDING
17256886 EI211 1
HYDRANT PUMP HOUSE CONTROL PANEL
LAYOUT
17256888 EI221 1 SEAPORT PUMP HOUSE CONTROL PANEL LAYOUT
17256899 E-506 1 DETAILS – EFSO & SITE
17256921 EI662 1 I&C CIRCUIT SCHEDULE – SEAPORT PUMPHOUSE
17256922 EI663 1 I&C CIRCUIT SCHEDULE – HYDRANT PUMPHOUSE
17256924 EI702 1 INSTRUMENT SCHEDULE
17256925 EI703 1 INSTRUMENT SCHEDULE
17256929 EI801 1
HYDRANT CONTROL SYSTEM FUNCTIONAL
BLOCK DIAGRAM
17256930 EI802 1
SEAPORT CONTROL SYSTEM FUCTIONAL BLOCK
DIAGRAM
PART A: GENERAL REQUIREMENTS
SPECIFICATION
SECTION
CHANGE
NO.
TITLE
01 33 00 3 SUBMITTAL PROCEDURES
01 57 19.03 2 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL
CONTROLS
SECTION 01 33 00 SUBMITTAL PROCEDURES
Delete the Part B Submittal Register in its entirety and replace it with the attached Part B Submittal Register, Amendment 0004.
SECTION 01 57 19.03 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS
Delete the section in its entirety and replace it with the attached Section 01 57 19.03, Amendment 0004. The Tinian Annex A-109 FY20 MCAF Project P-9010 / PAF189010 APSI Fuel Tanks with Receipt Pipeline & Hydrant System, dated March 2022, was added after the Munitions Response Explosives Safety Submission Tinian Construction Support Annex A-01, dated May 2020.
PART B: FY19 P-9030 APSI – CARGO PAD WITH TAXIWAY EXTENSION, TINIAN ,CNMI
(WON 1581694)
CHANGE
NO.
TITLE
33 11 13 1 POTABLE WATER SUPPLY WELLS
33 16 15 2 WATER STORAGE STEEL TANKS
SECTION 33 11 13 POTABLE WATER SUPPLY WELLS
Delete the section in its entirety.
SECTION 33 16 15 WATER STORAGE STEEL TANKS
Delete the section in its entirety and replace it with the attached Section 33 16 15, Amendment 0004.
PART C: FY19 P-9040 APSI – MAINTENANCE SUPPORT FACILITY, TINIAN, CNMI
(WON 1581706)
CHANGE
NO.
TITLE
07 27 19.01 1 SELF-ADHERING AIR BARRIERS
SECTION 07 27 19.01 SELF-ADHERING AIR BARRIERS
Delete the section in its entirety and replace it with the attached Section 07 27 19.01 Self-Adhering Air Barriers, Amendment 0004.
PART D: FY20 P-9010 APSI – FUEL TANKS WITH RECEIPT PIPELINE, TINIAN, CNMI
(WON 1620531)
CHANGE
NO.
TITLE
33 09 53 1
AVIATION FUEL PUMP CONTROL AND
ANNUNCIATION SYSTEM
33 52 43.11 1 AVIATION FUEL MECHANICAL EQUIPMENT
33 52 43.13 1 AVIATION FUEL PIPING
SECTION 33 09 53 AVIATION FUEL PUMP CONTROL AND ANNUNCIATION SYSTEM
Delete the section in its entirety and replace it with the attached Section 33 09 53, Amendment 0004.
SECTION 33 52 43.11 AVIATION FUEL MECHANICAL EQUIPMENT
Delete the section in its entirety and replace it with the attached Section 33 52 43.11, Amendment 0004.
SECTION 33 52 43.13 AVIATION FUEL PIPING
Delete the section in its entirety and replace it with the attached Section 33 52 43.13, Amendment 0004.
(End of Summary of Changes)
1 2 3 4 5
D
C
B
A
1 2 3 4 5
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AS SHOWN
1581694
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
TEXAS REGISTERED ENGINEERING FIRM F-2966
A/E INFO
D
C
B
A
A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340
JEG NO. WFXO6305
DRAWFORM REVISION: 30 APR 2015
DATE
FY
M C
AF
P
-9
0/
PA
F1
A
PS
I C
AR
G O
P
AD
W
IT
H T
AX
IW
AY
E
XT
EN
SI
O
N
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
ENGINEERING (CIVIL/STRUCTURAL)
CONSTRUCTION MANAGEMENT PLANNING
DEVELOPMENT CONSULTATION
GEOGRAPHIC INFORMATION SYSTEMS
P.O. Box 8900 Tamuning, Guam 96131
ELP JCS EMS
SCALE
KEYNOTE TABLE - STRUCTURESA1 N.T.S.
CU107
KE
YN
O
TE
T
AB
LE
ST
R
U C
TU
R
ES
17230858
M
AR
AM
EN
D M
EN
T
N O
. 0
03/09/2022
03/23/2022
Evan Mizue
KennedK4 Snapshot
KennedK4 Text Box 03/09/2022
KHK SMC JDE
D
C
B
A
1 2 3 4 5
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AS SHOWN
1581694
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
TEXAS REGISTERED ENGINEERING FIRM F-2966
JACOBS GOVERNMENT SERVICES COMPANY
777 MAIN STREET
FORT WORTH, TEXAS 76102
A/E INFO
D
C
B
A
A/E Contract No. N62742-17-D-0003 A/E Task Order No. N6274218F0340
JEG NO. WFXO6305
DRAWFORM REVISION: 30 APR 2015
DATE
FY
M C
AF
P
-9
0/
PA
F1
A
PS
I C
AR
G O
P
AD
W
IT
H T
AX
IW
AY
E
XT
EN
SI
O
N
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
M
IS
C
EL
LA
N
EO
U
S D
ET
AI
LS
CU504
17230896
W/ Ø250 PVC ENCASEMENT
CONC. SUPPORT
GRAVEL BASE
AxB
CONC. COLLAR (21MPa)
500x500 (21MPa)
GATE VALVE
CONC. RING BASE
NEW CI VALVE BOX
300 x 300
PI
PE
O D
/2
A Ø150 250 450
B (21MPa)
PIPE SIZE DIA.
SIZES OF FOUNDATION
NEW Ø150 PVC(DOMESTIC)
NOTES:
1. SLOPE CONCRETE COLLAR AWAY FROM HYDRANT.
2. FOR REDUCED HEIGHT FIRE HYDRANT ASSEMBLY, MAX HEIGHT IS 762mm, BUT CANNOT BE MORE THAN 609mm ABOVE AIRFIELD PAVEMENT.
NTS
M
IN
D
EP
TH
(MECH JOINT TYPE)
OUTLETS
63 (2 EA) FIRE HOSE
WORD,"WATER"ON CI
NEW 150 GATE VALVE
LOCKED TYPE COVER
CONCRETE COLLAR
CONC SUPPORT
150 MECH JOINT INLET)
(DRY BARREL TYPE WITH
NEW FIRE HYDRANT4500 MAX
1000 MIN
CONNECTION FACING AIRFIELD
100 (1 EA) PUMPER
CRUSHER-RUN
FILL
22522575
600 x 600
(21MPa)
(21MPa)CONC.
COLLARFINISHED
GRADE
ELEVATION
CONCRETE
ANCHOR BLOCK
(21MPa)
NEW 150 PVC
NEW VALVE BOX
NEW 150 PVC
25.6M MIN TO CENTERLINE OF TAXIWAY
45.7M MAX TO CENTERLINE OF TAXIWAY
AIRFIELD
SHOULDER
SCALE
NEW FIRE HYDRANT DETAILC1 N.T.S. SCALE
GATE VALVE DETAILC4 N.T.S.
NOTES:
1. ASSUME VEHICLE TRAFFIC ARE ON ALL SIDES OF THE HYDRANT.
2. ONLY ADD BOLLARDS ON THE SIDE OF HYDRANT EXPOSED TO VEHICLE
TRAFFIC. A MINIMUM OF 2 BOLLARDS MUST BE INSTALLED.
HYDRANT
BOLLARD (TYP),
RE: B5/CU504
MAINTAIN
1000 SEPARATION
SCALEC3 N.T.S.
BOLLARD AT FIRE HYDRANT AND PIV
MIN.
CONCRETE FOOTING
GRADE SURFACE
25 CROWN
150 DIAMETER SCHEDULE
40 STEEL PIPE
75 DOME FILL POST
WITH CONCRETE
Ø300
(21 MPa)
SCALE
BOLLARD DETAILB5 N.T.S.
TYPICAL PLACEMENT OF PIPE
SCALE
WELL HEAD AND PUMP INSTALLATION DETAILA2 N.T.S.
NOTES:
1. TRANSITION FROM EXISTING WATERLINE TO NEW WATERLINE WITH
RESTRAINED FLANGED COUPLING ADAPTER AND FLANGE ISOLATING
GASKET KIT. FLANGED COUPLING ADAPTER SHALL BE
CEMENT-MORTAR LINED AND ITS EXTERIOR SURFACES SHALL BE
SHOP PRIMED AND FIELD COATED WITH ASPHALTIC COATING. FLANGE
FACES SHALL BE COATED WITH A MANUFACTURER- RECOMMENDED
RUST-PREVENTIVE COMPOUND. FURTHER, FLANGED COUPLING
ADAPTER SHALL BE DOUBLE WRAPPED WITH POLYETHYLENE
ENCASEMENT.
NOTE 1
M
AR
AM
EN
D M
EN
T
N O
. 0
03/09/2022
03/23/2022
Evan Mizue
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
KennedK4 Snapshot
KennedK4
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C 03/09/2022
03/23/2022
Evan Mizue
SCALE
SITE PLAN - AREA 3A1 1:400
CS103
SI
TE
P
LA
N
AR
EA
1 2 3 4 5
D
C
B
A
1 2 3 4 5
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AS SHOWN
1620531
N
AV
FA
C
P
AC
IF
IC
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
NORTH
AREA 3
KEY PLANNOTE:
UNLESS OTHERWISE STATED, ALL CIVIL AND
ELECTRICAL PLAN SHEETS DIMENSIONS ARE
IN METERS.
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
SITE PLAN GENERAL NOTES
KEYNOTES
LEGEND
X
251 FUEL STORAGE TANK
LIGHT POLES, REFER TO ELECTRICAL
PLANS
ASPHALT ROADWAY, RE: D3/CS500
HANDHOLE, MANHOLE, REFER TO ELECTRICAL
PLANS
MH
PIPE HEADWALL
CATCH BASINCB
CHAIN LINK FENCE WITH CONCRETE MOW
STRIP, RE: A4/CS504 & A4/CS505
STORM DRAIN MANHOLED
REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.
REFER TO SHEET CS503 FOR MARKING DETAILS.
REFER TO ARCHITECTURAL PLANS FOR EXACT
BUILDING DIMENSIONS AND SPECIFICATIONS.
REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING
INFORMATION.
REFER TO SHEET CF150 FOR TANK FARM INFORMATION.
REFER TO SHEET CS601 FOR SITE PLAN POINT TABLES.
N&E POINT NUMBER
246 FUEL CONTAINMENT STRUCTURE, RE: A1/CG504
ALL AREA DISTURBED BY CONSTRUCTION ACTIVITIES
THAT ARE UNPAVED MUST BE SEEDED PER
SPECIFICATION 32 92 19
213 ROADWAY EDGE LINE STRIPING (TYP), RE: D4/CS503
P
150 MM WHITE LINE209
257 REFUELER PARKING AREA
A
C
B
D E F G
219 PAVEMENT REPAIR, RE: B2/CS501
218 ASPAHLT PAVEMENT TO EXIST, RE: D4/CS500
CONCRETE SIDEWALK, RE: C2/CS500
HEAVY DUTY CONCRETE PAVEMENT, RE: D1/CS500
238 ASPHALT PAVEMENT, RE: D3/CS500
258 SPLASH PAD, RE: B4/CG502
17256558
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
KennedK4 Snapshot
KennedK4
SCALE
SITE PLAN - AREA 5A1 1:400
CS105
SI
TE
P
LA
N
AR
EA
1 2 3 4 5
D
C
B
A
1 2 3 4 5
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AS SHOWN
1620531
N
AV
FA
C
P
AC
IF
IC
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
KEY PLANNOTE:
UNLESS OTHERWISE STATED, ALL CIVIL AND
ELECTRICAL PLAN SHEETS DIMENSIONS ARE
IN METERS.
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
220 GRAVEL ROADWAY, GRAVEL PAVEMENT, RE: B4/CS500
KEYNOTES
LEGEND
SITE PLAN GENERAL NOTES
214 SEAPORT PUMPHOUSE UST PAD, RE: C3/CF403
222 SIDEWALK, RE: C2/CS500
237 SAWCUT PAVEMENT, RE: D4/CS500
REFER TO ELECTRICAL PLANS FOR ALL SITE LIGHTING
INFORMATION.
REFER TO SHEET CS500 FOR PAVEMENT SECTIONS.
250 MECHANICAL YARD
X
BUILDING
203 BIOSECURITY CONTAINMENT FACILITY, RE: A1/CS502
256 PUMP AND CONTROLS BUILDING
CHAIN LINK FENCE, RE: CS507
GRAVEL, RE: B4/CS500
ASPHALT PAVEMENT, RE: D3/CS500
CONCRETE SIDEWALK, RE: C2/CS500
LIGHT POLE, REFER TO ELECTRICAL PLANS
HANDHOLE, MANHOLE, REFER TO ELECTRICAL
PLANS
CHAIN LINK FENCE WITH CONCRETE MOW
STRIP, RE: CS507
219 PAVEMENT REPAIR, RE: B2/CS501
REFER TO SHEET CS601-CS602 FOR SITE PLAN POINT
TABLES.
N&E POINT NUMBER
ALL AREA DISTURBED BY CONSTRUCTION ACTIVITIES
THAT ARE UNPAVED MUST BE SEEDED PER
SPECIFICATION 32 92 19
FIRE HYDRANT
212 DOUBLE SWING GATE, RE: C2/CS505
OVERHEAD ELECTRIC LINEOHW
314 BOLLARD, RE: A2 & A3/A-541
315 PAD MOUNTED TRANSFORMER, RE: A1/E-503
A
B C
D
CHAIN LINK FENCE WITHOUT BARBS, RE: C1/CS508201
REFER TO SHEET CS503 FOR MARKING DETAILS.E
HEAVY DUTY CONCRETE PAVEMENT, RE: B2/CS500
REFER TO SHEET CF151 FOR FUEL TANK INFORMATION.F
316 PEDESTRIAN GATE, RE: A3/CS507
317 PORTABLE GENERATOR, RE: ELECTRICAL PLANS
EXISTING GRAVEL
MHP
STOP BAR STRIPING, RE: C4/CS503206
STOP SIGN, RE: A1/CS503207
AREA 5
17256560
2.000
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
AutoCAD SHX Text
WV(2)
AutoCAD SHX Text
FUEL LINE
AutoCAD SHX Text
WPP
AutoCAD SHX Text
WPP
AutoCAD SHX Text
CPP
AutoCAD SHX Text
GW
AutoCAD SHX Text
WV
AutoCAD SHX Text
FH
AutoCAD SHX Text
WPP
AutoCAD SHX Text
WPP
AutoCAD SHX Text
WV(2)
AutoCAD SHX Text
CPP
AutoCAD SHX Text
CPP
AutoCAD SHX Text
CPP
AutoCAD SHX Text
CPP
KennedK4 Snapshot
KennedK4
C
B
A
1 2 3 4 5
AS SHOWN
1620531
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
NOTE:
UNLESS OTHERWISE STATED, ALL CIVIL AND
ELECTRICAL PLAN SHEETS DIMENSIONS ARE
IN METERS.
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
CS503
SI
TE
D
ET
AI
LS
NOTE:
UNLESS OTHERWISE STATED, ALL
DIMENSIONS ARE IN MILLIMETERS.
R1-1 610x610
STOP SIGN DETAIL
SCALE
SIGN POST AND SIGN DETAILA1 N.T.S.
(T
YP
BACK OF
CURB
EDGE OF
DRIVEWAY
STOP BAR
T O
STOP SIGN
VARIES
NOTE:
1. IF NO CROSSWALK IS PRESENT AT STOP BAR LOCATION THEN THE STOP BAR MUST
BE PLACED 3600mm FROM EDGE OF DRIVEWAY.
SCALE
STOP BAR DETAILC4 N.T.S.
DIA.
2 6 GALVANIZED STEEL
SQUARE TUBING
WITH 7/16 HOLES
SPACED AT 25 O.C.
51 SQUARE GALVANIZED
STEEL TUBING WITH 7/16
HOLES SPACED AT 25 O.C.
GENERAL NOTES:
1. SIGN DETAILS MUST CONFORM TO THE LATEST EDITIONS OF FHWA PUBLICATIONS
"MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS",
"STANDARD ALPHABETS FOR HIGHWAY SIGNS", AND AS AMENDED.
2. SIGN MUST BE HIGH INTENSITY REFLECTIVE SHEETING UNLESS OTHERWISE
SPECIFIED.
3. SIGN MUST HAVE 9.5mm BOLT HOLES DRILLED AT APPROXIMATE LOCATIONS.
4. SIGN LETTERING MUST BE UPPER CASE.
5. SIGN BACKGROUND MUST BE WHITE.
6. PAINT BACK OF SIGN WHITE.
7. REFLECTORIZED SIGNS MUST BE MADE OF ALUMINUM ATTACHED TO STEEL POST
(NO HOLES AND CAPPED AT TOP OF POST) WITH STAINLESS STEEL BOLTS.
SIGN VARIES PER PLAN.
SEE DETAILS TO THE RIGHT
FOR SPECIFIC SIGN
8 DIA. MACHINE
BOLTS BOTH WAYS
SLOPE TO DRAIN
FINISH GRADE
SECTION VIEW
16Ø X127 LONG BOLT
CONCRETE FOOTING
CROSSWALK
REFLECTIVE
WHITE TRAFFIC
PLACARD OR SPECIAL
LICENSE PLATE AND I.D.
REQUIRED
MAXIMUM FINE $500
R7-8 304x457
ACCESSIBLE PARKING
SIGN DETAIL
R7-20 304x152
SCALE
ADA LOGO DETAILC1 N.T.S.
150 WHITE
STRIPE (TYP.)
2400 ACCESS AISLE
CONCRETE
WHEEL STOP
RE: C2/CS506
100 WIDE WHITE
PAVEMENT STRIPE.
SCALE
PARKING SPACE STRIPING DETAILC2 N.T.S.
ACCESSIBLE
SIGN AND POST
RE: A1/CS503
WHITE TRAFFIC
PAINT
R=508 152 102
20°
152305
5°
NOTE: TYPICAL LAYOUT DETAIL.
RETRO REFLECTIVE
WHITE STRIPE
EDGE OF
PAVEMENT
SCALE
ROADWAY EDGE LINE STRIPING DETAILD4 N.T.S.
L
DETAIL "A"
C LINE
0 36
CROSSLINES
WHITE STRIPE
CROSSWALK
WHITE STRIPE
17256594
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
RESERVED
KennedK4 Snapshot
KennedK4
C
B
A
1 2 3 4 5
AS SHOWN
1620531
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
CS506
SI
TE
D
ET
AI
LS
NOTE:
UNLESS OTHERWISE STATED, ALL
DIMENSIONS ARE IN MILLIMETERS.
SCALE
PADLOCKABLE CANE BOLTA3 N.T.S.
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWINGS.
3. GATE HEIGHT MUST MATCH THE HEIGHT OF THE CONTAINMENT WALL.
4. REFER TO DETAIL C4 FOR LOUVER CONFIGURATION FOR GATE AND
SECTION 2.7.4 OF SPECULATION 32 31 13.53 FOR MORE INFORMATION.
PADLOCKABLE
CANE BOLT,
RE: A3/CS506
PADLOCKABLE
SLIDE BOLT
60.325 X 7.9375 OR 76.200 X 7.9375
BAR OR SQUARE TUBING
25.400, 38.100, OR 50.800
SQUARE TUBING
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE
WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWINGS.
RECESSED STRIKE
PADLOCK
(FURNISHED BY
OTHERS)
9.525 X 457.200
CANE BOLT
GATE FRAME
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWINGS.
SECTION
SEAL 13 DEEP HOLE
WITH MORTAR
#19 @ 760 LONG
2-25 Ø HOLES
SCALE
TYPICAL BOLLARD DETAILC1 N.T.S.
SCALE
PRECAST CONCRETE WHEEL STOPC2 N.T.S.
SCALE
BIOSECURITY CONTAINMENT METAL LOUVERA1 N.T.S. SCALE
HINGEA4 N.T.S.
STEEL HINGE,
RE: A4/CS506
NOTE:
1. PROVIDE POLYETHYLENE PROTECTIVE COVER.
COLOR MUST BE YELLOW.
SET POST IN CONCRETE
FILL POST WITH
CONCRETE (100 MIN)
100 DIAMETER
GALVANIZED
STEEL PIPE
GRADE
OPEN AREA VISUAL SCREENING MAX. LENGTH
40.8% 100% 1524
DIRECT VISUAL SCREENING
100%
NO GAP
.0
Ø
SCALE
GATE LOUVERSC4 N.T.S.
17256597
2-#10 REBAR
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
AutoCAD SHX Text
6.350 X 44.450
AutoCAD SHX Text
24.602 X 10.319 X 2.381
AutoCAD SHX Text 4.763
KennedK4 Snapshot
KennedK4
VA
R
IE
S
1 2 3 4 5
D
C
B
A
1 2 3 4 5
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AS SHOWN
1620531
N
AV
FA
C
P
AC
IF
IC
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
CG500
D R
AI
N
AG
E
D
ET
AI
LS
NOTE:
UNLESS OTHERWISE STATED, ALL
DIMENSIONS ARE IN MILLIMETERS.
Ø 900
VA
R
IE
S
NOTES:
1. DRAINAGE MANHOLE IS ASSUMED TO BE A PRECAST MANHOLE, DESIGNED BY THE
CONTRACTOR.
2. DESIGN TO BE BASED ON H20 (147kPa) LOADING.
3. MANHOLES LOCATED ON THE APRON MUST BE AIRCRAFT RATED, BOLTED DOWN, AND DESIGNED
FOR 45,500KG.
4. REFER TO SPECIFICATION 33 40 00 FOR LADDER INFORMATION. FIRST RUNG MUST BE NO MORE
THAN 205MM FROM THE BOTTOM OF THE RIM AND THE BOTTOM RUNG NO MORE THAN 610MM
FROM THE BOTTOM OF THE STRUCTURE. LADDER MUST BE POSITIONED TO NOT BLOCK THE
FLOW OF A PIPE.
6.25 606.25 2525
37.5
768.75
6.25 18.75 18.75
18.75 87.5
6.25
587.5
6.25 43.75
37.5
25 DIA.
HOLE
CAST IRON
56.25
CAST IRON
8-RIBS
SPACED
EQUALLY
FRAME - SECTION A2-B
FRAME - PLAN
COVER - PLAN
COVER - SECTION A2-C
SECTION B SECTION C
18.75
3.
.1
SCALE
STORM DRAIN MANHOLE DETAILA1 N.T.S.
SCALE
MANHOLE FRAME AND COVER DETAILSA3 N.T.S.
SCALE
CATCH BASIN DETAILSB4 N.T.S.
NOTE:
ALL GRATES LOCATED WITHIN 15 METERS OF AIRFIELD PAVEMENT MUST BE BOLTED DOWN.
COVER - BOTTOM VIEW
.7
.1
157.813
.1
VA
R
IE
S
VA
R
IE
S
VA
R
IE
S
NTS
SECTION A1-B
NTS
PLAN
NTS
SECTION A1-C
A2-B
CG500
A2-C
CG500
A1-C
CG500
A1-B
CG500
"C" DIA.
WALL THICKNESS
OF OUTFALL PIPE
(MIN)
SECTION 2
HALF PLAN
SECTION 1
FINISH
GRADE
NOTES:
1. CATCH BASIN IS ASSUMED TO BE A PRECAST CATCH BASIN, DESIGNED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR EITHER DESIGN AS THE DEPTH VARIES.
2. COVER MUST BE A GRATE WITH A MINIMUM OPEN AREA OF 0.25SM.
3. DESIGN TO BE BASED ON H20 (147kPa) LOADING.
4. CATCH BASINS LOCATED ON AIRFIELD PAVEMENT MUST BE AIRCRAFT RATED, BOLTED DOWN, AND DESIGNED FOR 455,000KG AND WHEEL LOADS WITH 1.72 MPA TIRE PRESSURE.
CG500
CG500
NTS
TYPICAL PLAN VIEW
NTS
INLET GRATE AND FRAME
NTS
ELEVATION
C
TO
GROUT
FLARE ENTRANCE
TO OUTFALL PIPE
OUTFALL PIPE
RIM OR TOP
ELEVATIONFRAME
CHAMFER
37.5 (TYP)
FINISH
GRADE
VA
R
IE
S
PLAIN CONCRETE
(18MPa)
STRAIGHT WALL
LOWER SLANT WALL
STRAIGHT WALL
LOWER SLANT WALL
UPPER SLANT WALL
ADJUST BLOCK
AC PAVEMENT
UPPER ADJUST HEIGHT
(WASHER FOR ADJUSTMENT
AND MORTAR)
Ø 900
ROCK BOLT
(M16)
CAST-IRON
COVER
Ø 900 UPPER ADJUST HEIGHT (WASHER
FOR ADJUSTMENT AND MORTAR)
AC PAVEMENT
CAST-IRON COVER
STRAIGHT WALL
STRAIGHT WALL
LOWER SLANT WALL
UPPER SLANT WALL
ADJUST BLOCK
BODY BLOCK (WALL FOR
PIPE INSTALLATION)
PLAIN CONCRETE
(18MPa)
7@37.5=262.5
MINIMUM
WATERWAY
AREA 0.25SM
17256600
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
KennedK4 Snapshot
KennedK4
KHK GFB JDE
D
C
B
A
1 2 3 4 5
AS SHOWN
1620531
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
CG501
D R
AI
N
AG
E
D
ET
AI
LS
NOTE:
UNLESS OTHERWISE STATED, ALL
DIMENSIONS ARE IN MILLIMETERS.SCALE
PIPE HEADWALL DETAILSA3 N.T.S.
B
M
IN
GRAVEL
B + 200 MIN.
1/6 B
NOTES:
1. SEE SPECIFICATIONS FOR MATERIAL AND COMPACTION REQUIREMENTS.
2. MAXIMUM PARTICLE SIZE IN GRAVEL MUST BE 12 MM FOR PLASTIC PIPE OR COATED OR WRAPPED PIPE AND 75 MM MAXIMUM
FOR ALL OTHER TYPES OF PIPE.
3. EMBEDMENT SIDE CLEARANCE MUST BE 300 MM FOR PIPES LESS THAN 450 MM IN DIAMETER AND 450 MM FOR PIPE GREATER
THAN 450 MM IN DIAMETER.
4. BEDDING DEPTH MUST BE INCREASED TO 150 MM IN ROCK CUTS.
5. MINIMUM COVER FOR CONSTRUCTION LOADS OVER PLASTIC PIPES MUST BE AS SPECIFIED IN ASTM D 2321.
LEGEND:
B = OUTSIDE PIPE DIAMETER
D = INSIDE PIPE DIAMETER
C
C
C
FINAL BACKFILL
C
LIMESTONE SILTY SAND
C
DETECTABLE
WARNING STRIP
150 ABOVE PIPE
B ,100 MIN.
CL
LC
TABLE OF VARIABLE DIMENSIONS
BARS D BARS E BARS FBARS CBARS BBARS A
T1 T2 U NO. SIZE NO. SIZE NO. SIZE NO. SIZE NO. SIZE NO. SIZE
PIPE
SIZE
D
NUMBER
OF
PIPE* H L W X T & T3**
750 1
1 600 600 1515 800 150
150 250
250 430
430 150
150 5
51000
750 900
1500 3030
2 4
10 4
300 4
NO.SIZENO.
BARS H BARS J
SIZE
SPACING NORMAL
TO CURB
BARS G
NO. SIZE
WINGWALL
BARS F
BAR J
BARS H
BARS G
BARS A
BARS C
BARS D
BARS E AT
12" CENTERS
BARS B
BARS B
BARS E
BARS D
BARS A
BARS C
BAR J
BARS G
BARS A
BARS C
BARS G
BARS F
BARS H AT
12" CENTERS
BAR J
BARS D
BARS B
BAR E
BARS B
GENERAL NOTES:
1. REINFORCING STEEL FY = 60 KSI.
** FOR CONCRETE CAST AGAINST THE EARTH, THE T3 DIMENSION MUST BE INCREASED TO A MINIMUM OF 200.
*** INCREASE CLEARANCE TO A MINIMUM OF 75 IF TRENCHED.
PLAN VIEW NOTES:
1. BARS D MUST BE SPACED AT 300 CENTERS.
2. BARS E MUST BE SPACED AT 300 CENTERS AND MUST BE SPACED SYMMETRICALLY ABOUT CENTERLINE.
3. EMBED BARS F AND H INTO HEADWALL 200.
* FOR MULTIPLE INSTALLATIONS HAVING MORE THAN TWO PIPES THE DIMENSION "X" IS TO BE INCREASED BY THE VALUE D + 3D/4 FOR EACH ADDITIONAL PIPE. ADDITIONAL BARS C & E ARE TO BE PROVIDED AND
SPACED AS SHOWN.
PIPE HEADWALL DETAIL NOTES:
225 TYP.
T H D
X
T3
L T1
U
W
X
6"
T1
D H
T3
T2
SCALE
PIPE BEDDING DETAILC4 N.T.S.
PLAN
TYPICAL WINGWALL SECTION RCP
ELEVATION SECTION ON PIPE L
PIPE HEADWALL DETAILS
C
B
M
IN
BC
C
FINAL BACKFILL
100 MIN.
BEDDING
PLASTIC PIPE
H
AU
N C
H
ZO
N E
IN
IT
IA
L
BA
C
KF
IL
L
SIDE CLEARANCESIDE CLEARANCE
SPRINGLINE
900 1 150 300 480 150 51200 1800 3530 1400 3 4 6 11 4 14 2
#13 #13 #13 #13 #13 #13 #13#13#13
#13 #13 #13 #13 #13 #13 #13#13#13
#13 #13 #13 #13 #13 #13 #13#13#13
#13 #13 #13 #13 #13 #13 #13#13#13
#13 #13 #13 #13 #13 #13 #13#13#13
300 480 150 5 3 4 8 14 4 20 22@200,4@250,4@300 10#13 #13 #13 #13 #13 #13 #13#13#131200 1 1501500 2400 4570 1780
17256601
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
KennedK4 Snapshot
KennedK4
C
B
A
1 2 3 4 5
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AS SHOWN
1620531
N
AV
FA
C
P
AC
IF
IC
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
CG502
D R
AI
N
AG
E
D
ET
AI
LS
NOTE: UNLESS OTHERWISE STATED, ALL DIMENSIONS ARE IN MILLIMETERS.
PIPE SIZE VARIES WYE PVC
450 SQUARE FINISHED GRADE
CLEANOUT
STRAIGHT PIPE
THREADED OUTLET
45° PVC BEND
CONC
COLLAR
PIPE SIZE VARIES
SCALE
GROUND CLEANOUT DETAILC4 N.T.S.
6:1 MAX
VARIES
MITER PIPE TO MATCH SLOPE
DRAIN PIPE FOR STORAGE
TANK, RE: F-111
100 CONCRETE APRON
450 THICK RIP-RAP
D100 = 300 D50 = 200 D10 = 75
SCALE
RIP-RAP DETAILD1 N.T.S.
SCALE
DRAIN PIPE OUTFALLB4 N.T.S.
SCALE
CONCRETE SWALE DETAILC3 N.T.S.
#13 @ 450
OCEW
15 MM Ø
26 MM 358 MM 26 MM
410 MM
26 MM
358 MM 26 MM
410 MM
6 MM
26 MM
26 MM
26 MM
308 MM
340 MM
SCALE
OUTFALL CONTROL STRUCTURE - PLAN VIEWA1 N.T.S. SCALE
OUTFALL CONTROL STRUCTURE - SECTION VIEWA3 N.T.S. SCALE
OUTFALL CONTROL STRUCTURE - PROFILE VIEWA5 N.T.S.
150 THICK 19 MM TO 50 MM
CLEAN CRUSHED GRAVEL
ON FILTER FABRIC
SCALE
BMP TRASH RACKB3 N.T.S.
26 MM
50 MM
1220 MM
50 MM
26 MM
1372 MM
20 MM Ø
NOTE: TRASH RACK MUST BE CONSTRUCTED OF
GALVANIZED STEEL.
2 1
SCALE
PEAK TRASH TRASH RACKB1 N.T.S.
M M
1052 MM
900 MM
M M
900 MM
450 MM
CATCH BASIN,
RE: B4/CG500
BMP PEAK ROOF TRASH RACK
WITH ACCESS HATCH,
RE: B1/CG502
ISOLATION JOINT
BMP TRASH RACK,
RE: B3/CG502
900 MM
900MM
PEAK ROOF TRASH RACK
WITH ACCESS HATCH. MAXIMUM 76 MM
CLEAR OPENING.
RE: A2/CG502
BMP TRASH RACK,
RE: B3/CG502
FG
50 MM DIA. ORIFICE
FG
FG
CONCRETE GROUT FILL AS
NEEDED TO TRANSITION
BETWEEN THE FLOWLINES
FINISHED GRADE
LINE (BEYOND)
RIP RAP PILOT CHANNEL
ELEV. A
D
D
SECTION D-D
SECTION C-C
CC
NOTES:
1. TRASH RACKS MUST BE CONSTRUCTED OF GALVANIZED STEEL.
RE: A2/CG502
RE: A5/CG502
M M
300MM (MIN)
COVER
RIP RAP,
RE: D1/CG502
CONCRETE SLAB,
RE: D1/CS501
CATCH BASIN,
RE: B4/CG500
CATCH BASIN,
RE: B4/CG500
CONCRETE GROUT
FILL AS NEEDED TO
TRANSITION
BETWEEN THE
FLOWLINES
ELEV. A
375 MM RCP
17256602
AM
EN
D M
EN
T
N O
. 0
M
AR
03/09/2022
03/23/2022
Evan Mizue
KennedK4 Snapshot
KennedK4
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC DATE
APPROVED
AS SHOWN
1620531
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
A/E INFO
A/E Contract No. N62742-17-D-0003
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
DRAWFORM REVISION: 30 APR 2015
DES DRW CHK
CHECK GRAPHIC SCALES BEFORE USING
ALL DIMENSIONS ARE METERS (m)
UNLESS OTHERWISE NOTED
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
Daniel C. Weathers
CE-14866
M
AT
C H
LI
N
E C
F1
M
AT
C H
LI
N
E C
F1
NORTH
SCALE: 1:500
POL PIPELINE PLAN 10C2
PO
L
PI
PE
LI
N
E
PL
AN
A
N D
P R
O
FI
LE
CF111
17256697
MPF SMH CAB
CF111
SCALE: H:1:500
POL PIPELINE PROFILE 10A2
V:1:50
NOTES
1. VERIFY OVERHEAD GUY WIRE. REMOVE AND REPLACE AS
NEEDED TO INSTALL POL LINE. BRACE POLE AS NECESSARY
DURING CONSTRUCTION.
SURFACING TABLE
STATIONS EXISTING
SURFACE
NEW
SURFACE
TRENCH
SECTION
CLEARING
LIMITS
3+747 - 3+755 ASPHALT ASPHALT B2/CS501 B2/CS501
Daniel C. Weathers
CE-14866
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC DATE
APPROVED
AS SHOWN
1620531
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
A/E INFO
A/E Contract No. N62742-17-D-0003
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
DRAWFORM REVISION: 30 APR 2015
DES DRW CHK
CHECK GRAPHIC SCALES BEFORE USING
ALL DIMENSIONS ARE METERS (m)
UNLESS OTHERWISE NOTED
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
Daniel C. Weathers
CE-14866
PO
L
PI
PE
LI
N
E
PL
AN
A
N D
P R
O
FI
LE
CF112
17256698
MPF SMH CAB
SCALE: 1:500
POL PIPELINE PLAN 11C2
NORTH
SCALE: H:1:500
POL PIPELINE PROFILE 11A2
V:1:50
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC DATE
APPROVED
AS SHOWN
1620531
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
A/E INFO
A/E Contract No. N62742-17-D-0003
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
DRAWFORM REVISION: 30 APR 2015
DES DRW CHK
CHECK GRAPHIC SCALES BEFORE USING
ALL DIMENSIONS ARE METERS (m)
UNLESS OTHERWISE NOTED
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
Daniel C. Weathers
CE-14866
M
AT
C H
LI
N
E C
F1
SCALE: 1:500
POL PIPELINE PLAN 12C2
NORTH
PO
L
PI
PE
LI
N
E
PL
AN
A
N D
P R
O
FI
LE
CF113
17256699
MPF SMH CAB
CF113
SCALE: H:1:500
POL PIPELINE PROFILE 12A2
V:1:50
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC DATE
APPROVED
AS SHOWN
1620531
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
A/E INFO
A/E Contract No. N62742-17-D-0003
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
DRAWFORM REVISION: 30 APR 2015
DES DRW CHK
CHECK GRAPHIC SCALES BEFORE USING
ALL DIMENSIONS ARE METERS (m)
UNLESS OTHERWISE NOTED
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
Daniel C. Weathers
CE-14866
MATCHLINE CF113
M
AT
C H
LI
N
E C
F1
NORTH
SCALE: 1:500
POL PIPELINE PLAN 13C2
PO
L
PI
PE
LI
N
E
PL
AN
A
N D
P R
O
FI
LE
CF114
17256700
MPF SMH CAB
CF114
SCALE: H:1:500
POL PIPELINE PROFILE 13A2
V:1:50
SURFACING TABLE
STATIONS EXISTING
SURFACE
NEW
SURFACE
TRENCH
SECTION
CLEARING
LIMITS
4+443 - 4+448 ASPHALT ASPHALT B2/CS501 B2/CS501
4+448 - 4+660 VEGETATION GRAVEL
ROAD C5/CF501 3 m EITHER
SIDE OF
WEEP HOLE, ALIGNED
OVER RADIAL GUTTER
TANK
SHELL
BOTTOM
PLATE
GEOMEMBRANE
6 x 50 CONT STAINLESS STEEL
BATTEN BAR WITH SLOTTED
HOLES @ 250 OC
10 DIA HEX HEAD NUT
10 DIA
HEX BOLT
40 mm LONG
6 x 75 CONT CARBON
STEEL PLATE W/
SLOTTED
HOLES @ 250 OC
FLAT WASHER
GEONET
SCALE: 1:1
GEOMEMBRANE ATTACHMENT DETAILD2
16 DIA BRACKET
ORIENTED TOWARDS
CENTER OF TANK
AT EACH SUPPORT
TANK
BOTTOM
PLATE
P 30 x 380 SQ W/ R50
CORNERS
254 DIA
EXTRA
STRONG
PIPE (TYP)
L
P 30 x 380 SQ
W/ R50 CORNERS
AND 150 DIA HOLE
FOR CONCRETE FILL
L
TOP
AND
BOT
TANK ROOF PLATE
13 DIA
25 DIA MIN
TANK SHELL
GEONET
GEOMEMBRANE
L100 x 100 x 10 x 200 LG
TOP OF STEEL TANK
ELEV = 85.725
SEAL GEOMEMBRANE
AROUND LEAKAGE
TEST PIPE
THREADED
CAP
LEAKAGE
TEST PIPE
38 DIA STD WT
0±
0±
0±
TOP OF STEEL
FLOOR PLATE
AT SHELL
ELEV = 78.500
TOP OF
STEEL TANK
ELEV = 85.725
6 mm TOP PLATE
75 x 75 x 7.9
RIM ANGLE
10 mm THICK
3RD SHELL COURSE
10 mm THICK
2ND SHELL COURSE
10 mm THICK
1ST SHELL COURSE
8 mm THICK
BOTTOM PLATE
75 18 680 ID
STEEL TANK
5%
GEOMEMBRANE
D2
SP502
D3
SP502
D5
SP502
2 PASS
GEONET
CJP 4 (TYP)
TANK ROOF
PLATE
HEX
HEAD NUT
FLAT
WASHER
10 DIA
THREADED STUD
50 LONG @ 500 OC
6 x 50 CONT STAINLESS
STEEL BATTEN BAR
WITH SLOTTED HOLES
GEOMEMBRANE
GEONET
SEALANT
FLOOR 8LP
5 x 50 STEEL
BACKER BAR
POCKET IN GROUT
FOR BACKER BAR
FLOOR 8LP
5x50 STEEL
BACKER BAR
RING 13LP
3 200
SCALE: 1:1
FLOOR JOINT AT SUMP RINGC3
POCKET IN GROUT
FOR BACKER BAR
SCALE: 1:1
ROOF JOINTB5
ROOF 6LP
300300300 300 300 30010
TY
P
TY
P
13 DIA ADHESIVE
ANCHOR BOLT
W/ 150 MIN EMBED
(TYP OF 4)
TY
P
CONC ID 2 000
STEEL SUMP
ID ABOVE
W200 x 15
(TYP OF 7)
L55 x 55 x 5
EA SPACE
CL
BEAM
CL
BEAM
CL
BEAM
CL
BEAM
CL
BEAM
CL
BEAM
CL
BEAM
NOTES
1. DIMENSIONS ARE APPROXIMATE.
2. TANK BOTTOM (FOR SHELL HEIGHT DIMENSIONS) IS THE TOP
ELEVATION OF BOTTOM PLATE AT SHELL-TO-BOTTOM JOINT.
SHELL MANHOLE DIMENSIONS
T LHR WHR DHR
8 1 850 2 235 920
L
HR
L H R
WHR
DHR
ALTERNATIVE SHAPE IF REQUIRED
TO MEET WELD SPACING REQUIREMENTS
NAME PLATE
DHR/2
TYP
T
O
D
BO
LT
C
IR
C
LE
D
IA
DAVIT, BY MFR
16 DIA
BAR HANDLE
(42) 22 DIA HOLES EQ
SPACED - STRADDLE VERT
CENTERLINE. PROVIDE 19 DIA
HEX HEAD BOLTS AND NUTS
SP503
A3
1 898
SEE MECH
TANK AXIS
TANK
BOTTOM
PLATE
5%
A1
SP502
SS L50 x 50 x 6 (4 @ 90°)
400 DIA
400 DIA
6 SS PLATE
USE E-308L
ELECTRODES
NOTE
1. BEARING TABLE TO BE LOCATED BENEATH HATCH & PIPE. SEE
MECHANICAL.
TANK
BOTTOM
PLATE
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
TI
N
IA
N
IN
TE
R N
AT
IO
N
AL
A
IR
PO
R
T (T
IQ
TI
N
IA
N
, C N
M I
N
AV
FA
C
P
AC
IF
IC
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
M
AK
AL
AP
A, H
AW
AI
I
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC DATE
APPROVED
AS SHOWN
1620531
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
SEAL
A/E INFO
A/E Contract No. N62742-17-D-0003
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
FY
M C
AF
P
-9
/ P
AF
A
PS
I F U
EL
T
AN
KS
W
IT
H R
EC
EI
PT
P
IP
EL
IN
E
H
YD
R
AN
T
SY
ST
EM
FI
N
AL
R
E- D
ES
IG
N S
U
BM
IT
TA
L
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
DRAWFORM REVISION: 30 APR 2015
ENGINEERING, INC.
DES DRW CHK
CHECK GRAPHIC SCALES BEFORE USING
ALL DIMENSIONS ARE MILLIMETERS (mm)
UNLESS OTHERWISE NOTED
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CN
KY
K. YOSHIMOTO
JC
SJDMJBDAS
17256764
SP502
ST
EE
L
TA
N K
D
ET
AI
LS
SCALE: 1:20
0 200 400 800
SCALE: 1:5
0 50 100 200
SCALE: 1:10
0 100 200 400
SCALE: 1:1
FLOOR JOINTC2
SCALE: 1:20
ROOF SUPPORT COLUMNB4
SCALE: 1:4
LEAK DETECTION PIPE (TYP OF 4)D3 SCALE: 1:1
GEOMEMBRANE ATTACHMENT
TO THREADED STUD
D5
SCALE: NTS
ANCHOR STUD DETAILA3 SCALE: 1:20
SUPPORT BEAMS BELOW SUMPA4
TANK STEEL WALL SECTION
SCALE: 1:5C1
SCALE: 1:20
SHELL MANHOLE DETAILA2
SCALE: 1:20
MANHOLE COVERB3
SCALE: 1:20
STEEL SUMP DETAILB1
SCALE: 1:10
BEARING TABLEA1
SCALE: 1:1
0 10 20 40
SCALE: 1:4
0 40 80 160
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
24 SEP 2021
For Amendment 4
ES105
SI
TE
P
LA
N
AR
EA
ATG BB AM
1 2 3 4 5
D
C
B
A
1 2 3 4 5
AS SHOWN
1620531
TEXAS REGISTERED ENGINEERING FIRM F-2966
D
C
B
A/E Contract No. N62742-17-D-0003
DRAWFORM REVISION: 30 APR 2015
A/E Task Order No. N6274219F0304
JEG NO. WFXO6309
NORTH
AREA 5
KEY PLANNOTE:
UNLESS OTHERWISE STATED, ALL CIVIL AND
ELECTRICAL PLAN SHEETS DIMENSIONS ARE
IN METERS.
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
DATE
MARK PETERSEN, PM, PER
SAT-TO FORM DTD 01 OCT 2021
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
FIRE PROTECTION
CN
KY
K. YOSHIMOTO
JC
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE
SCALE
SITE PLAN - AREA 5A1 1:400
KEYNOTES
001 PROVIDE MAINTENANCE HOLE. RE: A1/E-501. TYP.
002 PROVIDE FUSED CUT-OUTS TO TRANSITION FROM
OVERHEAD TO UNDERGROUND. RE: A1/E-502.
003 PROVIDE PAD-MOUNTED TRANSFORMER. RE: A1/E-503 FOR
DETAIL AND E-602 FOR ONE LINE DIAGRAM.
004 RE: EP102 FOR SECONDARY INTO THE BUILDING AND E-602
FOR WIRE AND CONDUIT SIZES.
005 PROVIDE HANDHOLE. RE: A3/E-502. TYP.
006 PROVIDE A PRIMARY METERING UNIT CABINET FOR
COMMONWEALTH UTILITIES CORPORATION METERING, PER
UTILITY COMPANY REQUIREMENTS, INCLUSIVE OF METER
SOCKETS, CABINETS, METERING DEVICES, CONDUITS, ETC.,
FOR A COMPLETE AND OPERATIONAL SYSTEM. THIS
INCLUDES, BUT IS NOT LIMITED TO, (3) EACH POTENTIAL
TRANSFORMERS AND CURRENT TRANSFORMERS, AND
13/JAW WITH TEST SWITCH METER BASE MOUNTED TO THE
POLE. RE: A1/E-502.
007 PROVIDE 480V, 3 PHASE FEEDER (3#12, 1#12G IN 53 MM
CONDUIT) TO POWER LIGHTS. RE: C3/E-505 FOR CIRCUITING
DIAGRAM.
008 CONNECT TO EXISTING IT&E COMMUNICATIONS HANDHOLE.
009 PROVIDE (1) 103 MM CONCRETE ENCASED CONDUIT. RE:
A3/E-631 AND C3/E-505 FOR CONDUIT QUANTITIES AND
ADDITIONAL PATHWAY INFORMATION.
010 NOT USED.
011 ROUTE ELECTRICAL DUCTBANK BELOW COMMUNICATIONS
DUCTBANK CROSSING.
012 PROVIDE (1) 53 MM CONDUIT FOR INTRINSICALLY SAFE
CIRCUITING. RE: EI662 FOR CONDUCTOR SIZING.
013 RE: A1/E-509 FOR PRODUCT RECOVERY TANK DETAIL.
014 RE: A1/ES106 FOR CONTINUATION TO MARINE OFFLOADING
AREA.
015 MOUNT EMERGENCY SHUT OFF ON STAINLESS STEEL
STRUCTURAL METAL CHANNEL STAND. COORDINATE
BOLLARD LOCATION WITH CIVIL. RE: B3/E-506.
016 PROVIDE (1) 53 MM CONDUIT FOR EFSO WIRING.
017 PROVIDE (1) 53 MM CONDUIT FOR POWERING PRODUCT
RECOVERY TANK.
SFA-20
SFA-30
SA2
009011
GENERAL NOTES
A REFER TO THESE SHEETS FOR ADDITIONAL INFORMATION:
GI015/GI016 - HAZARDOUS AREA PLANS
E-001 - GENERAL NOTES AND LEGEND.
E-601 - ONE-LINE DIAGRAM.
E-611/E-612 - LUMINAIRE SCHEDULE AND DETAILS.
E-621 - EQUIPMENT INFORMATION AND CIRCUIT NUMBERS.
EI654, EI655, EI661 - EFSO PB SWITCH CONTROL DIAGRAM.
NUMBERS NEXT TO SWITCH INDICATE UNIQUE ID.
B PROVIDE CONCRETE ENCASEMENT UNDER PAVEMENT, UP TO
1.5 M BEYOND THE EDGE OF PAVEMENT FOR UNDERGROUND
CONDUIT. ENCASE PRIMARY CONDUIT FOR THE FULL LENGTH.
S-HP:15,17,19
AB
SFA-20
S-HP:15,17,19
AB
SFA-20
S-HP:15,17,19
CA
S-HP:
15,17,19
BC
S-HP:
16,18,20
AB
SA2-2
S-HP:16,18,20
BC
SA2
S-HP:16,18,20
CA
SA2
S-HP: 15,17,19
BC
17256873
012 012
AM
EN
D M
EN
T
M
AR
ANDREW T. GARDNER
OF
A
130901
24 SEP 2021
For Amendment 4
SCALE: 1:100
0 2000 4000
1 2 3 4 5
D
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
24 SEP 2021
For Amendment 4
SCALE: 1:100
0 2000 4000
1 2 3 4 5
D
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
24 SEP 2021
For Amendment 4
8 TEST RESET
A B C D E F G
7 SIL ACK
1 2 3 4 5
D
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
A B C D E
5 SIL ACK
6 TEST RESET
1 2 3 4 5
D
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
ANDREW T. GARDNER
OF
A
130901
24 SEP 2021
For Amendment 4
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
C
B
A
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
ENSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC SCALES
1 2 3 4 5
D
C
B
A
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 1 OF 65 PAGES
PART B: FY19 P-9030 APSI Cargo Pad with Taxiway Extension, Tinian
02 41 00 SD-01 Preconstruction Submittals
1.2.1 GDemolition Plan
1.10Existing Conditions
SD-07 Certificates
1.6 GNotification
03 30 00 SD-01 Preconstruction Submittals
1.6.3.1Concrete Curing Plan
1.6.5 GQuality Control Plan
1.6.6 GQuality Control Personnel
Certifications
1.6.6Quality Control Organizational
Chart
1.6.8 GLaboratory Accreditation
1.6.2.1 GForm Removal Schedule
3.3.8Maturity Method Data
SD-02 Shop Drawings
1.6.2.1Formwork
1.6.2.2 GReinforcing Steel
SD-03 Product Data
2.4.4Joint Sealants
2.4.3Joint Filler
2.1Formwork Materials
2.3.1Cementitious Materials
2.4.5Vapor Retarder
2.4.1Concrete Curing Materials
2.6Reinforcement
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
AUTH REMARKS
(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)
Amendment 0004 3/9/2022
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 2 OF 65 PAGES
03 30 00 2.3.4Admixtures
2.6.5Reinforcing Fibers
2.6.2Mechanical Reinforcing Bar
Connectors
2.2.2Waterstops
2.2.3Biodegradable Form Release
Agent
1.6.3.2Pumping Concrete
2.4.2Nonshrink Grout
SD-05 Design Data
1.6.1.2 GConcrete Mix Design
1.6.1.1Formwork Calculations
SD-06 Test Reports
1.6.1.2 GConcrete Mix Design
1.6.4.1Fly Ash
1.6.4.1Pozzolan
1.6.4.2Slag Cement
1.6.4.3Aggregates
1.6.4.4 GFiber-Reinforced Concrete
3.13.2.3 GCompressive Strength Tests
3.13.2.5Unit Weight of Structural
Concrete
3.13.2.6Chloride Ion Concentration
3.13.2.4Air Content
3.13.2.1Slump Tests
2.3.2Water
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
AUTH REMARKS
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 3 OF 65 PAGES
03 30 00 SD-07 Certificates
2.6.1Reinforcing Bars
1.8Welder Qualifications
1.6.3.3VOC Content for Form Release
Agents, Curing Compounds, and
Concrete Penetrating Sealers
1.6.3.4Safety Data Sheets
1.6.6.2Field Testing Technician and
Testing Agency
SD-08 Manufacturer’s Instructions
2.4.4Joint Sealants
2.4.1Curing Compound
04 20 00 SD-02 Shop Drawings
3.3.2.1Cut CMU
3.4.1.1Detail Drawings
SD-03 Product Data
1.5.1Hot Weather Procedures
2.4.1.1Cementitious Materials
SD-04 Samples
2.2.2.2Concrete Masonry Units (CMU)
2.4.1.3Admixtures for Masonry Mortar
2.6.2Anchors, Ties, and Bar
Positioners
2.6.3Joint Reinforcement
SD-05 Design Data
2.1.2Masonry Compressive Strength
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
AUTH REMARKS
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 4 OF 65 PAGES
04 20 00 3.2.4Bracing Calculations
SD-06 Test Reports
3.6.1.1Field Testing of Mortar
3.6.1.2Field Testing of Grout
SD-07 Certificates
1.3.1Special Masonry Inspector
Qualifications
2.2.2.2Concrete Masonry Units (CMU)
2.2.3Precast Concrete Units
2.4.1.1Cementitious Materials
2.4.1.3Admixtures for Masonry Mortar
2.4.2.2Admixtures for Grout
2.6.2Anchors, Ties, and Bar
Positioners
2.6.3Joint Reinforcement
SD-08 Manufacturer’s Instructions
2.4.1.3Admixtures for Masonry Mortar
2.4.2.2Admixtures for Grout
05 05 23.16 SD-01 Preconstruction Submittals
3.2 GWelding Quality Assurance Plan
SD-03 Product Data
1.3 GProcedure Qualification Records
1.3.4Welder, Welding Operator, and
Tacker Performance Qualification
Records
1.3.2Previous Qualifications
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
AUTH REMARKS
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 5 OF 65 PAGES
05 05 23.16 1.3.3 GPre-Qualified Procedures
2.2Welding Electrodes and Rods
SD-06 Test Reports
3.3Nondestructive Testing
3.2Weld Inspection Log
SD-07 Certificates
1.3.1Welding Procedure Specifications
(WPS)
1.3.1Procedure Qualification Records
(PQR)
1.3.1Welder Performance
Qualifications (WPQ)
1.3.1Welder Logs
1.3.5Certified Welding Inspector
1.3.5Nondestructive Testing Personnel
05 12 00 SD-01 Preconstruction Submittals
1.4.1.1 GErection Drawings
SD-02 Shop Drawings
1.4.2 GFabrication Drawings
SD-03 Product Data
2.4.1Welding Electrodes and Rods
2.4.2Non-Shrink Grout
2.2.3Gratings
SD-06 Test Reports
2.3Bolts, Nuts, and Washers
3.6.1.2Weld Inspection Reports
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
AUTH REMARKS
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 6 OF 65 PAGES
05 12 00 3.6.2Embrittlement Test Reports
SD-07 Certificates
2.2Steel
2.3Bolts, Nuts, and Washers
2.5Galvanizing
1.3AISC Structural Steel Fabricator
Quality Certification
1.3AISC Structural Steel Erector
Quality Certification
1.4.3.1Welding Procedures and
Qualifications
2.4.1Welding Electrodes and Rods
3.6.1.1Certified Welding Inspector
3.6.1.2NDT Technician
3.4Welding Procedure Specifications
(WPS)
05 40 00 SD-02 Shop Drawings
1.6.1 GFraming Components
SD-03 Product Data
2.1Studs, Joists
2.1 SRecycled Content of Steel
Products
SD-05 Design Data
1.6.2 GMetal Framing Calculations
SD-07 Certificates
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .