Attachment Z - Amend0004_DWG_10of12_PLUMB.pdf
PDF 1 MB Posted
- Solicitation number
- N6247023R0004
View the file
Other files
Show 40 more
Latest 50 of 85 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JK
L
M
100 RDN FR BLW & UP
WUB-1
DUB-1
FD
FD
100 SAN FR ABV
ABV CLG
BLW GRD
100 SAN FR ABV
40 SAN FR ABV
50 V UP
100 SAN
22.017
MECHANICAL ROOM
ENTRY STORAGE
STORAGE
GARAGE
FOYER
LAUNDRY
22.237
JK
L
M
S-1
100 SAN FR ABV & DN
LV-3
WC-1
100 RDN FR BLW & UP
50 V FR BLW & UP
40 V UP
50 V UP
CO
100 SAN FR ABV & DN
100 SAN DN
LIVING ROOM
BALCONY
KITCHEN
DINING
FAMILY
22.021
40 V
GENERAL NOTES: /
NOTE GENERALI
1. SEE SHEET P-001 FOR PLUMBING GENERAL NOTES, ABBREVIATIONS & SYMBOLS. /
FARE RIFERIMENTO ALLA TAVOLA P-001 PER LE NOTE GENERALI DELL'IMPIANTO
IDRICO SANITARIO, ABBREVIAZIONI E SIMBOLI
2. SEE SHEET P-600 FOR EQUIPMENT SCHEDULES. /
FARE RIFERIMENTO ALLA TAVOLA P-600 PER LE TABELLE DEGLI APPARATI
3. SEE RISER DIAGRAMS FOR ADDITIONAL INFORMATION AND DETAILS. /
FARE RIFERIMENTO AGLI SCHEMI DELLE COLONNE MONTANTI PER INFORMAZIONI E
PARTICOLARI AGGIUNTIVI.
4. PROVIDE ACCESS PANEL THROUGHOUT FOR ALL EQUIPMENT REQUIRING
MAINTENANCE. / FORNIRE PANNELLI DI ACCESSO PER TUTTE LE
APPARECCHIATURE CHE RICHIEDONO MANUTENZIONE.
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SCE
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :4
B
IM
B P A M E R
V ic e n za p h a s e
IV
A F H P
TH
P b u ild in g .r vt
SGS NSLSGS
3B R
C O
R N
E R
T H
G R
O U
N D
A N
D F
IR
S
T
FL
O O
R W
A S
TE
P
LA
N
3B R
C O
R N
E R
T H
P
IA
N
TA
S C
A R
IC
H
I P
IA
N O
T E
R R
A E
P R
IM
O
PW422
14126918
S G S
SCALE 1 : 50
B1
3BR CORNER TH GROUND FLOOR WASTE PLAN /
3BR CORNER TH PIANTA SCARICHI PIANO TERRA
SCALE 1 : 50
A3
3BR CORNER TH FIRST FLOOR WASTE PLAN /
3BR CORNER TH PIANTA SCARICHI PIANO PRIMO
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
22.017 PROVIDE UNDERGROUND SANITARY PIPING. SEE CIVIL DRAWINGS FOR
CONTINUATION. / FORNIRE TUBAZIONI SANITARIE INTERRATE. VEDI
DISEGNI OPERE CIVILI PER LA CONTINUAZIONE.
22.021 ROUTE DISHWASHER SANITARY TO SINK SANITARY PIPING. SEE DETAIL
C3/P-501. / COLLEGARE LO SCARICO DELLA LAVASTOVIGLIE ALLO
SCARICO DEL LAVELLO. VEDI DETTAGLIO C3/P-501.
22.237 FOR TOWNHOUSE UNITS WITH MAT FOUNDATIONS, ROUTE PIPING DOWN
BELOW FOUNDATION WITH STEEL SLEEVE PROTECTING THE SANITARY
PIPE. PROVIDE A 25MM GAP BETWEEN THE SLEEVE AND PIPE. FOR
TOWNHOUSES WITH 460MM THICK FOUNDATIONS, USE INVERT 1709
BELOW FFE. FOR FOUNDATIONS 1000MM THICK, USE INVERT 2259 BELOW
FFE. / PER LE TOWNHOUSE CON FONDAZIONI SUPERFICIALI, CONDURRE
DELLE TUBAZIONI SOTTO LA FONDAZIONE CON MANICOTTO IN ACCIAIO A
PROTEZIONE DELLA TUBAZIONE SANITARIA. MANTENENDO UNO SPAZIO
DI 25 MM TRA IL MANICOTTO E IL TUBO. PER LE TOWNHOUSE CON
FONDAZIONI DI 460 MM DI SPESSORE, UTILIZZARE INVERTER 1709 SOTTO
FFE. PER FONDAZIONI DI SPESSORE 1000MM USARE INVERT 2259 SOTTO
FFE.
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
V T
T
U
FD
WUB-1
DUB-1
FD
50 V
100 RDN FR BLW & UP
50 V UP
100 SAN FR ABV
100 SAN
22.017
GARAGE
ENTRY
CLOSET
FOYER
MAIN ENTRYMECHANICAL ROOM
STORAGE
LAUNDRY
22.237
V T
T
U
LV-3
WC-1
100 SAN FR ABV
100 SAN DN
100 SAN FR ABV
S-1
40 V UP
50 V FR BLW
50 V UP
100 RDN FR BLW & UP
22.021
DINING
KITCHEN
LIVING ROOM
PANTRY
CIRCULATION
HALF BATH
FAMILY
GENERAL NOTES: /
NOTE GENERALI
1. SEE SHEET P-001 FOR PLUMBING GENERAL NOTES, ABBREVIATIONS & SYMBOLS. /
FARE RIFERIMENTO ALLA TAVOLA P-001 PER LE NOTE GENERALI DELL'IMPIANTO
IDRICO SANITARIO, ABBREVIAZIONI E SIMBOLI
2. SEE SHEET P-600 FOR EQUIPMENT SCHEDULES. /
FARE RIFERIMENTO ALLA TAVOLA P-600 PER LE TABELLE DEGLI APPARATI
3. SEE RISER DIAGRAMS FOR ADDITIONAL INFORMATION AND DETAILS. /
FARE RIFERIMENTO AGLI SCHEMI DELLE COLONNE MONTANTI PER INFORMAZIONI E
PARTICOLARI AGGIUNTIVI.
4. PROVIDE ACCESS PANEL THROUGHOUT FOR ALL EQUIPMENT REQUIRING
MAINTENANCE. / FORNIRE PANNELLI DI ACCESSO PER TUTTE LE
APPARECCHIATURE CHE RICHIEDONO MANUTENZIONE.
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SCE
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :4
B
IM
B P A M E R
V ic e n za p h a s e
IV
A F H P
TH
P b u ild in g .r vt
SGS NSLSGS
4B R
T H
G R
O U
N D
A N
D F
IR
S
T
FL
O O
R W
A S
TE
P
LA
N
4B R
T H
P
IA
N
TA
S C
A R
IC
H
I P
IA
N O
T E
R R
A , P
R
IM
O E
S E
C O
N D
O
PW424
14126920
S G S
SCALE 1 : 50
A1
4BR TH GROUND FLOOR WASTE PLAN /
4BR TH PIANTA SCARICHI PIANO TERRA
SCALE 1 : 50
A3
4BR TH FIRST FLOOR WASTE PLAN /
4BR TH PIANTA SCARICHI PIANO PRIMO
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
22.017 PROVIDE UNDERGROUND SANITARY PIPING. SEE CIVIL DRAWINGS FOR
CONTINUATION. / FORNIRE TUBAZIONI SANITARIE INTERRATE. VEDI
DISEGNI OPERE CIVILI PER LA CONTINUAZIONE.
22.021 ROUTE DISHWASHER SANITARY TO SINK SANITARY PIPING. SEE DETAIL
C3/P-501. / COLLEGARE LO SCARICO DELLA LAVASTOVIGLIE ALLO
SCARICO DEL LAVELLO. VEDI DETTAGLIO C3/P-501.
22.237 FOR TOWNHOUSE UNITS WITH MAT FOUNDATIONS, ROUTE PIPING DOWN
BELOW FOUNDATION WITH STEEL SLEEVE PROTECTING THE SANITARY
PIPE. PROVIDE A 25MM GAP BETWEEN THE SLEEVE AND PIPE. FOR
TOWNHOUSES WITH 460MM THICK FOUNDATIONS, USE INVERT 1709
BELOW FFE. FOR FOUNDATIONS 1000MM THICK, USE INVERT 2259 BELOW
FFE. / PER LE TOWNHOUSE CON FONDAZIONI SUPERFICIALI, CONDURRE
DELLE TUBAZIONI SOTTO LA FONDAZIONE CON MANICOTTO IN ACCIAIO A
PROTEZIONE DELLA TUBAZIONE SANITARIA. MANTENENDO UNO SPAZIO
DI 25 MM TRA IL MANICOTTO E IL TUBO. PER LE TOWNHOUSE CON
FONDAZIONI DI 460 MM DI SPESSORE, UTILIZZARE INVERTER 1709 SOTTO
FFE. PER FONDAZIONI DI SPESSORE 1000MM USARE INVERT 2259 SOTTO
FFE.
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
ABAA
100 RDN FR BLW & UP
100 SAN FR ABV
FD
FD
DUB-1
WUB-1
50 V UP
50 V
100 SAN
22.017
GARAGE
ENTRY
CIRCULATION
CLOSET
FOYER
MAIN ENTRY
MECHANICAL ROOM
LAUNDRY
22.237 20
ABAA
S-1
LV-3
WC-1
50 V FR BLW
100 SAN DN
100 SAN FR ABV 40 V UP
50 V UP
100 RDN FR BLW & UP
100 SAN FR ABV
LIVING ROOM
DINING
BALCONY
KITCHEN
CIRCULATION
FAMILY HALF BATH
22.021
GENERAL NOTES: /
NOTE GENERALI
1. SEE SHEET P-001 FOR PLUMBING GENERAL NOTES, ABBREVIATIONS & SYMBOLS. /
FARE RIFERIMENTO ALLA TAVOLA P-001 PER LE NOTE GENERALI DELL'IMPIANTO
IDRICO SANITARIO, ABBREVIAZIONI E SIMBOLI
2. SEE SHEET P-600 FOR EQUIPMENT SCHEDULES. /
FARE RIFERIMENTO ALLA TAVOLA P-600 PER LE TABELLE DEGLI APPARATI
3. SEE RISER DIAGRAMS FOR ADDITIONAL INFORMATION AND DETAILS. /
FARE RIFERIMENTO AGLI SCHEMI DELLE COLONNE MONTANTI PER INFORMAZIONI E
PARTICOLARI AGGIUNTIVI.
4. PROVIDE ACCESS PANEL THROUGHOUT FOR ALL EQUIPMENT REQUIRING
MAINTENANCE. / FORNIRE PANNELLI DI ACCESSO PER TUTTE LE
APPARECCHIATURE CHE RICHIEDONO MANUTENZIONE.
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SCE
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :3
B
IM
B P A M E R
V ic e n za p h a s e
IV
A F H P
TH
P b u ild in g .r vt
SGS NSLSGS
3B R
T H
G R
O U
N D
A N
D F
IR
S
T
FL
O O
R W
A S
TE
P
LA
N
3B R
T H
P
IA
N
TA
S C
A R
IC
H
I P
IA
N O
T E
R R
A E
P R
IM
O
PW420
14126916
S G S
SCALE 1 : 50
A1
3BR TH GROUND FLOOR WASTE PLAN /
3BR TH PIANTA SCARICHI PIANO PRIMO
SCALE 1 : 50
A3
3BR TH FIRST FLOOR WASTE PLAN /
3BR TH PIANTA SCARICHI PIANO TERRA
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
22.017 PROVIDE UNDERGROUND SANITARY PIPING. SEE CIVIL DRAWINGS FOR
CONTINUATION. / FORNIRE TUBAZIONI SANITARIE INTERRATE. VEDI
DISEGNI OPERE CIVILI PER LA CONTINUAZIONE.
22.021 ROUTE DISHWASHER SANITARY TO SINK SANITARY PIPING. SEE DETAIL
C3/P-501. / COLLEGARE LO SCARICO DELLA LAVASTOVIGLIE ALLO
SCARICO DEL LAVELLO. VEDI DETTAGLIO C3/P-501.
22.237 FOR TOWNHOUSE UNITS WITH MAT FOUNDATIONS, ROUTE PIPING
DOWN BELOW FOUNDATION WITH STEEL SLEEVE PROTECTING THE
SANITARY PIPE. PROVIDE A 25MM GAP BETWEEN THE SLEEVE AND PIPE.
FOR TOWNHOUSES WITH 460MM THICK FOUNDATIONS, USE INVERT 1709
BELOW FFE. FOR FOUNDATIONS 1000MM THICK, USE INVERT 2259
BELOW FFE. / PER LE TOWNHOUSE CON FONDAZIONI SUPERFICIALI,
CONDURRE DELLE TUBAZIONI SOTTO LA FONDAZIONE CON MANICOTTO
IN ACCIAIO A PROTEZIONE DELLA TUBAZIONE SANITARIA. MANTENENDO
UNO SPAZIO DI 25 MM TRA IL MANICOTTO E IL TUBO. PER LE
TOWNHOUSE CON FONDAZIONI DI 460 MM DI SPESSORE, UTILIZZARE
INVERTER 1709 SOTTO FFE. PER FONDAZIONI DI SPESSORE 1000MM
USARE INVERT 2259 SOTTO FFE.
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
2023-05-08T15:43:27+0200
2023-05-08T15:43:33+0200
2023-05-08T15:43:33+0200
| 2023-05-18T12:46:00-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
| 2023-05-18T12:46:23-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
| 2023-05-18T12:46:23-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
File details come from the government source that posted it. Updated .