2591214
I
G
E
H
J
D
C
B
A
67101113
F
20850
1500660
28009253450750715985241550024101000
3.22
3.23
3.23
3.22
3.23
3.22
3.22
3.23
3.23
3.23
3.22
3.22
9002160826582652160900
20850
5600404057003410
90020850900
90096407310900
-1.250
-1.250
-1.250
-1.250
-1.250
-1.250
-1.250
-1.250
-1.250
22650
18750
-1.500
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP21 22100 1.5
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :4
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
F
O U
N D
A
TI
O N
P
LA
N P
IA
N
TA
F
O N
D A
ZI
O
N I A
P E
D
IF
IC
IO
S-110
14126231
M H
SCALE 1 : 100
A1
AP BUILDING 22100 FOUNDATION PLAN /
PIANTA FONDAZIONI AP EDIFICIO 22100
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO
C1 SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO
C2 SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. TOP OF FOUNDATION ELEVATION IS -1250 mm / LA QUOTA TESTA FONDAZIONE È -1250 mm
5. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING /
FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL TERRENO
ADIACENTI ALL'EDIFICIO
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
7. REFER TO DETAIL A2 ON SHEET S-520 FOR "CONTINUITY OF FOUNDATION
REINFORCEMENT AT CORNERS & INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A2 DELLA TAVOLA S-520 PER LA
"CONTINUITÀ DELL'ARMATURA DI FONDAZIONE A
8. REFER TO DETAILS C3 OF S-524 AND C2 OF S-527 FOR DETAIL OF
FOUNDATION EXTERIOR WALL CHANGE IN THICKNESS/
VEDI DETTAGLI C3 DELL’ELABORATO S-524 E C2 DELL’ELABORATO S-527 PER IL
DETTAGLIO DELLA VARIAZIONE DI SPESSORE DEL SETTO ESTERNO SULLA
FONDAZIONE
FOUNDATION NOTES /
NOTE DI FONDAZIONE
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
Carbone, Lucrezia Stamp
G
E
H
J
D
C
B
A
67101113
F
A1 S-302A
A1 S-302A
B1 S-303A
B1 S-303A
A1 S-301A
A1 S-301A
C1 S-202A
C1 S-201A
A1 S-201A
A1 S-202A
A1 S-212A
A1 S-210A
A4 S-210A
A1 S-211A
A2 S-211A
A2 S-211A
A1 S-213A
A1 S-214A
A3 S-214A
A1 S-215A
A3 S-215A
A1 S-216A
A1 S-216A
A1 S-217A
A2 S-217A
A2 S-217A
A1 S-218A
A2 S-218A
A3 S-218A
A4 S-218A
A1 S-219A
A2 S-219A
A3 S-219A
2160826582652160
20850
1500660340280092534507507159852415500241010002402160
3.51
3.51
3.51
3.51
20850
2%2%
5% 5%
2%
3.08
3.08
AP
-2
1- W
AP
-2
1- W
AP
-2
1- W
AP-21-W4
AP-21-W1
AP
-2
1- W
AP-21-W25
AP-21-W11
AP-21-W11
AP-21-W12 AP
-2
1- W
AP-21-W11
AP
-2
1- W
AP
-2
1- W
AP-21-W13
AP
-2
1- W
AP-21-W23
AP-21-W4
AP
-2
1- W
AP-21-W3
AP
-2
1- W
AP
-2
1- W
AP
-2
1- W
AP
-2
1- W
AP-21-W20
AP
-2
1- W
AP
-2
1- W
AP-21-W3
AP-21-W2
AP
-2
1- W
AP
-2
1- W
AP-21-W2
AP
-2
1- W
AP
-2
1- W
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.70
3.08 3.08
3.51
3.08
3.08
3.55
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
AP-21-W13
3.51
3.51
3.51
3.33
3.55
3.31
3.32
3.31
3.51
3.083.08
3.08
3.08
3.08
3.08
3.08
3.32
3.31
3.31
3.33 3.51
3.08
3.22
3.22
3.23
3.23
8.11
AP
-2
1- W
AP
-2
1- W
3.303.30
3.08
5.11
LEGEND: /
LEGENDA
= DENOTES SLOPE /
INDICA PENDENZA
= DENOTES SLAB-STEP /
INDICA SCALINO SULLA SOLETTA
= INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD
BEARING CONCRETE WALL /
INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO DI
CEMENTO ARMATO PORTANTE.
= INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR
REINFORCENT OVER LOAD BEARING CONCRETE WALL /
INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA PARTE
SUPERIORE DELLA SOLETTA SOPRA LA PARETE PORTANTE
DI CEMENTO ARMATO.
= INDICATES CONCRETE WALL. SEE SHEAR WALL ELEVATIONS
FROM DRAWING S-210 TO S-220 /
INDICA PARETE IN CLS. VEDERE PARETE NELLA TABELLA
TAVOLA S-210 A S-220
AP-21-Wx
CONCRETE WALL NUMBER
BUILDING/BLOCK IDENTIFIER
SITE LOCATION
x%
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
T
Y P
IC
A
L
FL
O O
R F
R A
M
IN
G P
LA
N
P
IA
N
TA
S
TR
U
TT
U R
E A
P E
D
IF
IC
IO
P
IA
N
O T
IP
IC
O
S-112
14126233
M H
SCALE 1 : 100
A1
AP BUILDING 22100 TYPICAL FLOOR FRAMING PLAN /
PIANTA STRUTTURE AP EDIFICIO 22100 PIANO TIPICO
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE DETAIL
A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C1 SOLO AL
PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE DETAIL
A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C2 SOLO AL
PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.30 REINFORCED CONCRETE BEAM 300x550mm ONLY AT FIRST FLOOR. SEE DETAIL C2 ON SHEET S-551 / TRAVE IN CALCESTRUZZO ARMATO 300x550mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO C2 SUL FOGLIO S-551
3.31 REINFORCED CONCRETE BEAM 300x700mm ONLY AT FIRST FLOOR. SEE DETAIL C2 ON SHEET S-551 / TRAVE IN CALCESTRUZZO ARMATO 300x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO C4 SUL FOGLIO S-551
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE DETAIL C2 ON SHEET S-554 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-554
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY ON FIRST FLOOR / TRAVE in CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
3.55 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-555 / SCALA IN
CALCESTRUZZO GETTATO IN OPERA. VEDI DETTAGLIO COSTRUTTIVO A2
DELL'ELABORATO S-555
5.11 PROVIDE 2xØ12x1220 DIAGONAL CRACK BARS 50mm FROM CORNER AT 75mm CENTRES, CENTERED IN SLAB AT RE-ENTRANT SLAB CORNERS AS SHOWN / PREVEDERE 2xØ12x1220 ARMATURA PER FESSURAZIONE 50mm DALL'ANGOLO AL CENTRO 75mm, POSTO AL CENTRO DELLA SOLETTA AGLI
ANGOLI DELLA SOLETTA RIENTRANTE COME IN FIGURA
8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA
COLATA
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
5. SEE MEP DRAWINGS FOR ALL NECESARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
NOTE: TYPICAL FLOOR FRAMING PLAN SHOWS FIRST
SECOND AND THIRD FLOOR SLABS. SEE SECTIONS FOR
ELEVATIONS AT INDIVIDUAL LEVELS. /
NOTA: LA PIANTA TIPICA MOSTRA I SOLAI DEL PRIMO,
SECONDO E TERZO PIANO. PER I PROSPETTI DEI SINGOLI
LIVELLI, VEDERE LE SEZIONI.
G
E
H
J
D
C
B
A
67101113
F
3.51
3.08
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.70 3.51
3.08
8.02
AP
-2
1- W
AP
-2
1- W
19 AP
-2
1- W
AP
-2
1- W
AP-21-W20
AP
-2
1- W
3.60
5% 5%
3.60
3.51
2160826582652160
20850
20850
1500660
28009253450750715985241550024101000
14.750
3.603.60
5%5%
AP-21-W13
H=25+4(TYP)H=25+4(TYP)
H =2
5+ 4(
TY
P)
H =2
5+ 4(
TY
P)
3.08
5%
AP-21-W26
11.900
TOW 15.640
TOW 15.640
8.11
3.70
3.36
AP
-2
1- W
13.600
13.540
3.66
3.66
13.541
TOW 15.640
TOW 14.540
TOW 15.640 TOW 15.640
TOW 15.640
TOW 14.510
AP-21-W4
AP-21-W26
TOW 15.640 TOW 15.640
3.51
TOW 15.540
TOW 15.540
TOW 15.540 TOW 15.540
3.51
TOW 15.540
TOW 15.640
TOW 15.640
TOW 15.640
TOW 15.640
TOW 15.640
TOW 15.540
LEGEND: /
LEGENDA
= DENOTES SLOPE /
INDICA PENDENZA
= DENOTES SLAB-STEP /
INDICA SCALINO SULLA SOLETTA
= INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD
BEARING CONCRETE WALL /
INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO DI
CEMENTO ARMATO PORTANTE.
= INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR
REINFORCENT OVER LOAD BEARING CONCRETE WALL /
INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA PARTE
SUPERIORE DELLA SOLETTA SOPRA LA PARETE PORTANTE
DI CEMENTO ARMATO.
= INDICATES CONCRETE WALL. SEE SHEAR WALL ELEVATIONS
FROM DRAWING S-210 TO S-220 /
INDICA PARETE IN CLS. VEDERE PARETE NELLA TABELLA
TAVOLA S-210 A S-220
AP-21-Wx
CONCRETE WALL NUMBER
BUILDING/BLOCK IDENTIFIER
SITE LOCATION
x%
G D
F
30%
30%
3.61
3.61
3.51
3.08 14.850
H=20+5(TYP)
8.11
8.03
8.11
38002750
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
P
E N
TH
O
U S
E A
N D
R O
O F
FR
A
M
IN
G P
LA
N
P
IA
N
TA
S
TR
U
TT
U R
E A
P E
D
IF
IC
IO
P
IA
N
O A
TT
IC
O E
C O
B E
R
TU
R A
S-115
14126234
M H
SCALE 1 : 100
A1
AP BUILDING 22100 PENTHOUSE FRAMING PLAN /
PIANTA STRUTTURE AP EDIFICIO 22100 PIANO ATTICO
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.36 REINFORCED CONCRETE BEAM 500x290mm AT ROOF LEVEL / TRAVE IN CALCESTRUZZO ARMATO 500x290mm A LIVELLO DEL TETTO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-555 / SCALA IN
CALCESTRUZZO GETTATO IN OPERA. VEDI DETTAGLIO COSTRUTTIVO A2
DELL'ELABORATO S-555
8.02 LIFT PENETRATION / PENETRAZIONE DELL'ASCENSORE
8.03 1250x1250mm SMOKE HATCH OPENING. REFER TO DETAIL C1 ON SHEET
S-556 / APERTURA SPORTELLO FUMI 1250x1250mm. FARE RIFERIMENTO AL
DETTAGLIO C1 DELL'ELABORATO S-556
8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA
COLATA
SCALE 1 : 100
A3
AP BUILDING 22100 ROOF FRAMING PLAN /
PIANTA STRUTTURE AP EDIFICIO 22100 COPERTURA
ROOF PLAN NOTES /
NOTE SUL PIANO DEL TETTO
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR
PENETRATIONS NOT SHOWN. /
FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E IDRAULICI PER LE
PENETRAZIONI NON MOSTRATE.
5. H = HEIGHT OF ROOF STRUCTURAL SECTION (20cm PREDALLE SYSTEM + 5cm
SACRIFICIAL SLAB) /
H = ALTEZZA DELLA SEZIONE STRUTTURALE DEL TETTO (20cm SISTEMA PREDALLE + 5cm SOLAIO/
6. H = HEIGHT OF ROOF STRUCTURAL SECTION (25cm PREDALLE SYSTEM + 4cm
SACRIFICIAL SLAB) /
H = ALTEZZA DELLA SEZIONE STRUTTURALE DEL TETTO (25cm SISTEMA PREDALLE + 4cm SOLAIO/
7. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
5. SEE MEP DRAWINGS FOR ALL NECESARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
NOTE: PENTHOUSE LEVEL PLANS SHOW ROOF FRAMING
FOR LIVING QUATERS /
NOTA: I PIANI DEL LIVELLO ATTICO MOSTRANO
L'INTELAIATURA DEL TETTO PER LE STANZE ABITABILI
A
B
G
H
I
J
K
C
D
2578101112
14 13
E
A1 S-412
A1 S-203
C1 S-204
A1 S-304
A1 S-304
C1 S-305
C1 S-305
A1 S-305
A1 S-305
C1 S-306
C1 S-306
A1 S-306
A1 S-306
3.51
34709680217016301820275023002910
3 °
26730
20850 21608265
82652160
3.23
3.23
3.23
3.22
3.22
3.23
3.23
3.22
3.23 3.22
3.22
3.24
3.24 -1.500
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP12 21200 1.0
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :2
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTVPP
A P
B U
IL
D
IN
G
F
O U
N D
A
TI
O N
P
LA
N P
IA
N
TA
F
O N
D A
ZI
O
N I A
P E
D
IF
IC
IO
S-116
14126235
M H
SCALE 1 : 100
A1
AP BUILDING 21200 FOUNDATION PLAN /
PIANTA FONDAZIONI AP EDIFICIO 21200
FOUNDATION NOTES /
NOTE DI FONDAZIONE
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. TOP OF FOUNDATION ELEVATION IS -1250 mm / LA QUOTA TESTA FONDAZIONE È -1250 mm
5. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING /
FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL TERRENO
ADIACENTI ALL'EDIFICIO
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
7. REFER TO DETAIL A2 ON SHEET S-520 FOR "CONTINUITY OF FOUNDATION
REINFORCEMENT AT CORNERS & INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A2 DELLA TAVOLA S-520 PER LA
"CONTINUITÀ DELL'ARMATURA DI FONDAZIONE A
8. REFER TO DETAILS C3 OF S-524 AND C2 OF S-527 FOR DETAIL OF
FOUNDATION EXTERIOR WALL CHANGE IN THICKNESS/
VEDI DETTAGLI C3 DELL’ELABORATO S-524 E C2 DELL’ELABORATO S-527 PER IL
DETTAGLIO DELLA VARIAZIONE DI SPESSORE DEL SETTO ESTERNO SULLA
FONDAZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C1
SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C2
SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
B
G
H
I
J
K
C
D
2578101112
14 13
E
A1 S-412
B1 S-203
A1 S-203
C1 S-204
A1 S-204
A1 S-304
A1 S-304
C1 S-305
C1 S-305
A1 S-305
A1 S-305
C1 S-306
C1 S-306
A1 S-306
A1 S-306
3.51
34709680217016301820275023002910
3 °
26730
20850 21608265
82652160
3.23
3.23
3.23
3.22
3.22
3.23
3.23
3.22
3.23 3.22
3.22
3.24
3.24-1.500
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP22 22200 1.5
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :3
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTVPP
A P
B U
IL
D
IN
G
F
O U
N D
A
TI
O N
P
LA
N P
IA
N
TA
F
O N
D A
ZI
O
N I A
P E
D
IF
IC
IO
S-118
14126236
M H
SCALE 1 : 100
A1
AP BUILDING 22200 FOUNDATION PLAN /
PIANTA FONDAZIONI AP EDIFICIO 22200
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C1
SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C2
SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
FOUNDATION NOTES /
NOTE DI FONDAZIONE
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. TOP OF FOUNDATION ELEVATION IS -1250 mm / LA QUOTA TESTA FONDAZIONE È -1250 mm
5. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING /
FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL TERRENO
ADIACENTI ALL'EDIFICIO
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
7. REFER TO DETAIL A2 ON SHEET S-520 FOR "CONTINUITY OF FOUNDATION
REINFORCEMENT AT CORNERS & INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A2 DELLA TAVOLA S-520 PER LA
"CONTINUITÀ DELL'ARMATURA DI FONDAZIONE A
8. REFER TO DETAILS C3 OF S-524 AND C2 OF S-527 FOR DETAIL OF
FOUNDATION EXTERIOR WALL CHANGE IN THICKNESS/
VEDI DETTAGLI C3 DELL’ELABORATO S-524 E C2 DELL’ELABORATO S-527 PER IL
DETTAGLIO DELLA VARIAZIONE DI SPESSORE DEL SETTO ESTERNO SULLA
FONDAZIONE
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
B
G
H
I
J
K
C
D
2 5 7 8 10 11 12
E
3.51
900 3470 9680 2170 1630 1820 2750 2300 2910 4058
3 °
20850900 2160 8265 8265 2160 900
3.23
3.23
3.23
3.22
3.22
3.23
3.23
3.22
3.23
3.22
3.22
20850
16323
A1 S-307
A1 S-307
C1 S-308
C1 S-308
A1 S-308
A1 S-308
C1 S-309
C1 S-309
A1 S-309
A1 S-309
20850
16323
3.24 -1.250
3.24 -1.250
3.24 -1.250
26730
22650
5265 4398 5325 16700
12214
A1 S-551
A1 S-551
A1 S-551
A1 S-551
A1 S-551
-1.500
LEGEND: /
LEGENDA
= UNDERCUT DEPTH (BELOW THE BOTTOM
OF FOOTING): -1000mm
= UNDERCUT DEPTH (BELOW THE BOTTOM
OF FOOTING): -600mm
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP24 22400 0.60-1.0
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
F
O U
N D
A
TI
O N
P
LA
N P
IA
N
TA
F
O N
D A
ZI
O
N I A
P E
D
IF
IC
IO
S-120
14126238
M H
SCALE 1 : 100
A1
AP BUILDING 22400 FOUNDATION PLAN /
PIANTA FONDAZIONI AP EDIFICIO 22400
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C1
SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE
DETAIL A1 ON SHEET S-551 / PILASTRO IN CALCESTRUZZO ARMATO C2
SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-551
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. TOP OF FOUNDATION ELEVATION IS -1250 mm / LA QUOTA TESTA FONDAZIONE È -1250 mm
5. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING /
FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL TERRENO
ADIACENTI ALL'EDIFICIO
6. REFER TO DETAIL A2 ON SHEET S-520 FOR "CONTINUITY OF FOUNDATION
REINFORCEMENT AT CORNERS & INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A2 DELLA TAVOLA S-520 PER LA
"CONTINUITÀ DELL'ARMATURA DI FONDAZIONE A
7. REFER TO SHEET S-559 FOR TYPICAL MAT FOUNDATIONS /
FARE RIFERIMENTO ALLA TAVOLA S-559 PER I DETTAGLI TIPICI DELLA
FOUNDAZIONE
8. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
9. REFER TO DETAILS C3 OF S-524 AND C2 OF S-527 FOR DETAIL OF
FOUNDATION EXTERIOR WALL CHANGE IN THICKNESS/
VEDI DETTAGLI C3 DELL’ELABORATO S-524 E C2 DELL’ELABORATO S-527 PER IL
DETTAGLIO DELLA VARIAZIONE DI SPESSORE DEL SETTO ESTERNO SULLA
FONDAZIONE
10. BUILDINGS 22200 AND 22400 ARE STRUCTURALLY IDENTICAL FROM FIRST
FLOOR UP. BUILDINGS 22200 AND 22400 FOUNDATIONS HAVE UNIQUE
FOUNDATIONS /
GLI EDIFICI 22200 E 22400 SONO STRUTTURALMENTE IDENTICI DAL PRIMO
PIANO IN SU. GLI EDIFICI 22200 E 22400 HANNO FONDAZIONI UNICHE
11. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
FOUNDATION NOTES /
NOTE FONDAZIONE
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
B
G
H
I
J
K
C
D
2 5 7 8 10 11 12
E
5%
5%
2%
3.08 3.08
3.08
3.08
3.08
3.08
3.08
3.08
3.51
3.51
3.51
3.55
3.51 3.51
3.51
3.51
3.51
3.51
3.55
3.51
3.51
3470 9680 2170 1630 1820 2750 2300 2910
3 °
26730
20850 2160 8265
8265 2160
3.70
3.36
3.31
5% 5%
3.51
3.51
3.55
3.51
3.51
3.51
3.51 3.51
3.51 3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
AP-24-W1
AP-24-W1 AP-24-W1
AP-24-W22
AP-24-W26
AP
-2
4- W
AP
-2 4-
W
A P -2
4- W
AP-24-W9
AP-24-W9
AP-24-W9
AP-24-W7
AP
-2
4- W
A P -2
4- W
AP-24-W15
AP
-2
4- W
AP-24-W13
AP
-2
4- W
AP-24-W11
AP
-2
4- W
A P -2
4- W
A P
-2 4-
W
AP
-2
4- W
AP
-2
4- W
6 AP
-2
4- W
AP-24-W24
AP
-2
4- W
AP
-2
4- W
AP
-2
4- W
A P -2
4- W
AP
-2
4- W
2 AP-24-W35.11
3.33
3.33
3.31
3.31
3.08
A1 S-307
A1 S-307
C1 S-308
C1 S-308
A1 S-308
A1 S-308
C1 S-309
C1 S-309
A1 S-309
A1 S-309
3.30
3.30
2%
AP-24-W28
3.31
3.52
3.52
AP-24-W12
8.11
LEGEND /
LEGENDA
= DENOTES SLOPE /
INDICA PENDENZA
= DENOTES SLAB-STEP /
INDICA SCALINO SULLA SOLETTA
= INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD
BEARING CONCRETE WALL /
INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO
DI CEMENTO ARMATO PORTANTE
= INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR
REINFORCING OVER LOAD BEARING CONCRETE WALL /
INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA
PARTE SUPERIORE DELLA SOLETTA SOPRA LA PARETE
PORTANTE DI CEMENTO ARMATO
AP-24-Wxx = INDICATES CONCRETE WALL. SEE WALL ELEVATIONS FROM DRAWING S-2xx TO S-2xx /
INDICA PARETE IN CLS. VEDERE PARETE A TAGLIO DAL
DISEGNO DA S-2xx A S-2xx x%
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
T
Y P
IC
A
L
FL
O O
R F
R A
M
IN
G P
LA
N
P
IA
N
TA
S
TR
U
TT
U R
E A
P E
D
IF
IC
IO
P
IA
N
O T
IP
IC
O
S-123
14126240
M H
SCALE 1 : 100
A1
AP BUILDING 22400 TYPICAL FLOOR FRAMING PLAN /
PIANTA STRUTTURE AP EDIFICIO 22400 PIANO TIPICO
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.30 REINFORCED CONCRETE BEAM 300x550mm ONLY AT FIRST FLOOR. SEE
DETAIL C2 ON SHEET S-551 / TRAVE IN CALCESTRUZZO ARMATO
300x550mm SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO C2 SUL FOGLIO S-551
3.31 REINFORCED CONCRETE BEAM 300x700mm ONLY AT FIRST FLOOR. SEE
DETAIL C2 ON SHEET S-551 / TRAVE IN CALCESTRUZZO ARMATO
300x700mm SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO C4 SUL FOGLIO S-551
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY ON FIRST FLOOR / TRAVE in CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.36 REINFORCED CONCRETE BEAM 500x290mm AT ROOF LEVEL / TRAVE IN CALCESTRUZZO ARMATO 500x290mm A LIVELLO DEL TETTO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO
ARMATO 250mm
3.52 REINFORCED CONCRETE WALL 300mm / MURO IN CALCESTRUZZO
ARMATO 300mm
3.55 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-555 / SCALA
IN CALCESTRUZZO GETTATO IN OPERA. VEDI DETTAGLIO COSTRUTTIVO
A2 DELL'ELABORATO S-555
5.11 PROVIDE 2xØ12x1220 DIAGONAL CRACK BARS 50mm FROM CORNER AT 75mm CENTRES, CENTERED IN SLAB AT RE-ENTRANT SLAB CORNERS AS SHOWN / PREVEDERE 2xØ12x1220 ARMATURA PER FESSURAZIONE 50mm DALL'ANGOLO AL CENTRO 75mm, POSTO AL CENTRO DELLA SOLETTA AGLI
ANGOLI DELLA SOLETTA RIENTRANTE COME IN FIGURA
8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA
COLATA
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO DETAIL A3 ON SHEET S-551 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERS AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-551 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
5. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
6.SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
7. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
NOTE: TYPICAL FLOOR FRAMING PLAN SHOWS FIRST
SECOND AND THIRD FLOOR SLABS. SEE SECTIONS FOR
ELEVATIONS AT INDIVIDUAL LEVELS. /
NOTA: LA PIANTA TIPICA MOSTRA I SOLAI DEL PRIMO,
SECONDO E TERZO PIANO. PER I PROSPETTI DEI SINGOLI
LIVELLI, VEDERE LE SEZIONI.
B
G
H
I
J
K
C
D
2 5 7 8 10 11 12
E
3470 9680 2170 1630 1820 2750 2300 2910
13.540 3.08
3.51
3.51 3.51
3 °
26730
20850 2160 8265
8265 2160
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.513.51
10.200
11.900
AP-24-W13
AP
-2
4- W
AP-24-W11
AP-24-W15
AP
-2
4- W
A P -2
4- W
A P -2
4- W
AP-24-W16
AP-24-W9
AP-24-W9
AP
-2
4- W
AP-24-W7
AP
-2
4- W
AP-24-W1
AP-24-W1
AP-24-W1
AP-24-W22
AP
-2
4- W
AP
-2
4- W
AP
-2
4- W
AP
-2
4- W
AP-24-W24
AP-24-W6
AP
-2
4- W
AP
-2
4- W
A P -2
4- W
AP-24-W9
AP
-2
4- W
AP-24-W26
AP
-2
4- W
A P
-2 4-
W
A P -2
4- W
AP
-2
4- W
AP
-2
4- W
AP-24-W12
A1 S-307
A1 S-307
C1 S-308
C1 S-308
A1 S-308
A1 S-308
C1 S-309
C1 S-309
A1 S-309
A1 S-309
3.51
AP
-2
4- W
LEGEND /
LEGENDA
= DENOTES SLOPE /
INDICA PENDENZA
= DENOTES SLAB-STEP /
INDICA SCALINO SULLA SOLETTA
= INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD
BEARING CONCRETE WALL /
INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO
DI CEMENTO ARMATO PORTANTE
= INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR
REINFORCING OVER LOAD BEARING CONCRETE WALL /
INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA
PARTE SUPERIORE DELLA SOLETTA SOPRA LA PARETE
PORTANTE DI CEMENTO ARMATO
AP-24-Wxx = INDICATES CONCRETE WALL. SEE WALL ELEVATIONS FROM DRAWING S-2xx TO S-2xx /
INDICA PARETE IN CLS. VEDERE PARETE A TAGLIO DAL
DISEGNO DA S-2xx A S-2xx x%
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :0
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
P
E N
TH
O
U S
E F
R A
M
IN
G P
LA
N
P
IA
N
TA
S
TR
U
TT
U R
E A
P E
D
IF
IC
IO
P
IA
N
O A
TT
IC
O
S-124
14126241
M H
SCALE 1 : 100
A1
AP BUILDING 22400 PENTHOUSE FRAMING PLAN /
PIANTA STRUTTURE AP EDIFICIO 22400 PIANO ATTICO
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO DETAIL A3 ON SHEET S-551 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERS AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-551 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
5. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
6.SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
7. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
TOW
17700.000
GH D AF
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
3.08
3.08
3.08
3.08
3.08
3.08
3.09 3.09
3.08
3.08
3.08
3.61
16950380027508390
31890
A2 S-556
C1 S-559
D1 S-554
C3 S-554
B1 S-556
B1 S-556
3.60 3.60
3.08
3.66
3.66
14.750
13.677
A2 S-553
A2 S-553
A1 S-557
30%
B1 S-303
B1 S-303
A3 S-303
A3 S-303
3.08
3.51
3.51
3.51
3.51
3.51
3.51 3.51
3.08
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.513.51
3.51
3.51
3.51
SE_FOUNDATION TOC
-1250.000
18.797
17.570
3.51
TOW 15.540 TOW 15.640
-0.200 -0.200 13.13
13.13
2.03
3.24
-1.500
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP21 22100 1.5
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
S
E C
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
I
S-302
14126386
M H
SCALE 1 : 100 (S-303)
B1
AP BUILDING 22100 SECTION /
AP EDIFICIO 22100 SEZIONE
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
5. REFER TO DETAIL A3 ON SHEET S-521 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERS AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-521 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
2.03 ROCK FILL #57 STONE / RIEMPIMENTO DI ROCCIA #57
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO
ARMATO 250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN
PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO
ARMATO 150mm
13.13 FLOWABLE FILL / MASSETTO ALLEGGERITO
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
GH D AF
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
B1 S-303A
B1 S-303A
A3 S-303A
A3 S-303A
3.08
3.08
3.08
3.08
3.08
3.08
3.09 3.09
3.08
3.08
3.08
3.08
3.61
3.51
3.51
3.51
3.51
3.51
3.51
16950380027508390
31890
A2 S-556
C1 S-559
D1 S-554
C3 S-554
B1 S-556
B1 S-556
3.60 3.51
3.60 3.08
3.66
3.66
14.750
13.677
TOW 15.640 TOW 15.640TOW 15.540
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
A2 S-553
A2 S-553
A1 S-557
3.51
30%
SE_FOUNDATION TOC
-1250.000
17.570
18.797
3.24
-0.200-0.200 13.13
13.13
2.03
-1.500
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP21 22100 1.5
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
S
E C
TI
O
N B
ID
O
P
TI
O N
A P
E D
IF
IC
IO
S E
ZI
O
N I O
P
ZI
O N
E O
FF
E
R
TA
S-302A
14126387
M H
SCALE 1 : 100 (S-111)
A1
AP BUILDING 22100 SECTION /
AP EDIFICIO 22100 SEZIONE
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
5. REFER TO DETAIL A3 ON SHEET S-521 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERS AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-521 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
2.03 ROCK FILL #57 STONE / RIEMPIMENTO DI ROCCIA #57
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO
ARMATO 250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN
PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO
ARMATO 150mm
13.13 FLOWABLE FILL / MASSETTO ALLEGGERITO
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
4 6 7 10 11 13
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
A1 S-301
A1 S-301
B1 S-302
B1 S-302
3.61
3.093.01
3.08
3.08
3.08
3.08
3.08
3725 3450 2450 2415 2910
14950
3.70
3.70
3.70
3.70
C1 S-554
C3 S-556
B1 S-556
B1 S-556
C3 S-554C1
S-559
3.08 3.60
3.66
3.66 3.66
-0.600
A2 S-557
10.200
6.800
3.400
3.51
3.51
3.51
3.51
3.51
3.51
3.08
3.08
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51 3.51 3.51
3.513.51
3.51 3.51
3.51 3.51
3.51
3.51
3.51
B2 S-553
A1 S-557
14.750
SE_FOUNDATION TOC
-1250.000
5%
15.484 30%
3.24
-0.200
15.083
13.1313.13
2.03
-1.500 1381516
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
A1 S-301
A1 S-301
B1 S-302
B1 S-302
3.08
3.08
3.08
2160826582652160
20850
A2 S-553A1
S-556 A2
S-553
A1 S-553
B1 S-556
C1 S-559
3.333.33
3.51
5%5%
5%
A1 S-557
3.51
3.51
3.08
3.08
3.083.55 3.08
3.08
3.08
3.55
3.51
3.333.32
3.60
3.51
3.083.08
3.51
3.51
3.513.51
3.51
3.51
3.60
A2 S-554
14.420
SE_FOUNDATION TOC
-1250.000
5%
TOW 14.510 TOW 14.540
2.8602.860
3.24
13.13
2.03
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP21 22100 1.5
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :5
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
S
E C
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
I
S-303
14126388
M H
SCALE 1 : 100 (S-301)
B1
AP BUILDING 22100 CROSS SECTION 01 /
AP EDIFICIO 22100 SEZIONE TRASVERSALE 01
SCALE 1 : 100 (S-301)
A3
AP BUILDING 22100 CROSS SECTION 02 /
AP EDIFICIO 22100 SEZIONE TRASVERSALE 02
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
5. REFER TO DETAIL A3 ON SHEET S-521 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERS AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-521 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
2.03 ROCK FILL #57 STONE / RIEMPIMENTO DI ROCCIA #57
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE SLAB WITH Ø12/300 CENTERED
EACH WAY, TOP & BOTTOM / SOLETTA IN CALCESTRUZZO GETTATO IN
OPERA Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN
ENTRAMBE LE DIREZIONI
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE
DETAIL C2 ON SHEET S-554 / TRAVE IN CALCESTRUZZO ARMATO
400x700mm SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-554
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY ON FIRST FLOOR / TRAVE in CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO
ARMATO 250mm
3.55 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-555 / SCALA
IN CALCESTRUZZO GETTATO IN OPERA. VEDI DETTAGLIO COSTRUTTIVO
A2 DELL'ELABORATO S-555
13.13 FLOWABLE FILL / MASSETTO ALLEGGERITO
AM
EN
D-
FI
NA
L C
OM
ME
NT
S
/03 /20
W
HH
4 6 7 10 11 13
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
A1 S-302A
A1 S-302A
A1 S-301A
A1 S-301A
3.51
3.51
3.51
3.51
3.51
3.51
3.61
3.093.01
3.08
3.08
3.08
3.08
3.08
3.08
3.08
3725 3450 2450 2415 2910
14950
3.70
3.70
3.70
3.70
3.51
C1 S-554
C3 S-556
B1 S-556
B1 S-556
C3 S-554C1
S-559
3.08
3.60
3.66
3.66 3.66
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51 3.51 3.51
3.513.51
3.51 3.51
3.51 3.51
3.51
3.51
-0.600
A2 S-557
3.51
10.200
6.800
3.400
14.750
TOW 15.093
14.783
15.484
B2 S-553
A1 S-557
SE_FOUNDATION TOC
-1250.000
-0.200
3.24
30%
5%
13.1313.13
2.03
-1.500
1381516
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
A1 S-302A
A1 S-302A
A1 S-301A
A1 S-301A
3.55 3.08
3.08
3.08
3.55
3.51
2160826582652160
A2 S-553A1
S-556 A2
S-553
A1 S-553
B1 S-556
C1 S-559
3.333.323.33
3.60
3.51
5%5%
5%
3.083.08
3.51
3.51
3.513.51
TOW 14.510 TOW 14.540
A1 S-557
A2 S-554
3.51
3.51
3.60
2.860 2.860
14.420
SE_FOUNDATION TOC
-1250.000
5%
3.2413.13
2.03
BUILDING/
EDIFICI
#57 STONE FILL DEPTH (M)/
SPESSORE RIEMPIMENTO IN ROCCIA #57 (M)
AP21 22100 1.5
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
JTW
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:2 :0
B
IM
B P
AM
E R
V ic e n z a p h a s e
IV
A F H P A P S e n ve lo p e A .r vt
MH OTAGM
A P
B U
IL
D
IN
G
S
E C
TI
O
N B
ID
O
P
TI
O N
A P
E D
IF
IC
IO
S E
ZI
O
N I O
P
ZI
O N
E O
FF
E
R
TA
S-303A
14126389
M H
SCALE 1 : 100 (S-111)
B1
AP BUILDING 22100 CROSS SECTION 01 /
AP EDIFICIO 22100 SEZIONE TRASVERSALE 01
SCALE 1 : 100 (S-111)
A3
AP BUILDING 22100 CROSS SECTION 02 /
AP EDIFICIO 22100 SEZIONE TRASVERSALE 02
1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
3. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
4. REFER TO SHEET S-601 FOR BEAM REINFORCEMENT SCHEDULES /
FARE RIFERIMENTO ALLA TAVOLA S-601 AGLI ABACI DI RINFORZO DELLE TRAVI
5. REFER TO DETAIL A3 ON SHEET S-521 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERS AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-521 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
2.03 ROCK FILL #57 STONE / RIEMPIMENTO DI ROCCIA #57
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE SLAB WITH Ø12/300 CENTERED
EACH WAY, TOP & BOTTOM / SOLETTA IN CALCESTRUZZO GETTATO IN
OPERA Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN
ENTRAMBE LE DIREZIONI
3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER
PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.24 MAT FOUNDATION T=1000mm / BASE DELLA FONDAZIONE T=1000mm
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE
DETAIL C2 ON SHEET S-554 / TRAVE IN CALCESTRUZZO ARMATO
400x700mm SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-554
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY ON FIRST FLOOR / TRAVE in CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO
ARMATO 250mm
3.55 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-555 / SCALA
IN CALCESTRUZZO GETTATO…
This is the start of the file's text. The full file is on GovTribe.