Attachment H - DWG_39of42.pdf

PDF 25 MB Posted

Attached to
P91332, Phase 4 Family Housing at Villaggio, Vicenza, Italy
Solicitation number
N6247023R0004
Issued by

View the file

Other files

File Type Posted
N6247023R0004 Amend 0008.pdf PDF
N6247023R0004 Amend 0007.pdf PDF
Attachment AG_Amend0006_DWG_CIVIL.pdf PDF
N6247023R0004 Amend 0006.pdf PDF
Attachment AF_Amend0006_DWG_ELEC.pdf PDF
Attachment AH_Amend0006_DWG_LARCH.pdf PDF
Attachment AE_Amend0006_Spec.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_24MAY2023.pdf PDF
Attachment AD_DWG_1of1_ARCH.pdf PDF
Attachment AC_Amend0005_Spec.pdf PDF
N6247023R0004 Amend 0005.pdf PDF
Attachment Z - Amend0004_DWG_10of12_PLUMB.pdf PDF
Attachment AB - Amend0004_DWG_12of12_TELECOM.pdf PDF
Attachment X - Amend0004_DWG_8of12_INT.pdf PDF
Attachment AA - Amend0004_DWG_11of12_ELEC.pdf PDF
Attachment Q - Amend0004_DWG_1of12_GEN.pdf PDF
Attachment Y - Amend0004_DWG_9of12_FPE.pdf PDF
Attachment W - Amend0004_DWG_7of12_ARCH02.pdf PDF
Attachment R - Amend0004_DWG_2of12_CIV01.pdf PDF
N6247023R0004 Amend 0004.pdf PDF
Attachment V - Amend0004_DWG_6of12_ARCH01.pdf PDF
Attachment T - Amend0004_DWG_4of12_LARCH.pdf PDF
Attachment P - Amend0004_Spec Changes.pdf PDF
Attachment U - Amend0004_DWG_5of12_STR.pdf PDF
Attachment S - Amend0004_DWG_3of12_CIV02.pdf PDF
N6247023R0004 Amend 0003.pdf PDF
Attachment O - Site Visit Roster.pdf PDF
N6247023R0004 Amend 0002.pdf PDF
N6247023R0004 Amend 0001.pdf PDF
Attachment H - DWG_24of42.pdf PDF
Attachment H - DWG_06of42.pdf PDF
Attachment K - HAZMAT Report.pdf PDF
Attachment H - DWG_34of42.pdf PDF
Attachment H - DWG_19of42.pdf PDF
Attachment H - DWG_01of42.pdf PDF
Attachment H - DWG_42of42.pdf PDF
Attachment H - DWG_32of42.pdf PDF
Attachment L - DWG Index.pdf PDF
Attachment H - DWG_29of42.pdf PDF
Attachment H - DWG_12of42.pdf PDF
Attachment H - DWG_14of42.pdf PDF
Attachment H - DWG_21of42.pdf PDF
Attachment H - DWG_30of42.pdf PDF
Attachment M - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment I - UXO Report.pdf PDF
Attachment H - DWG_18of42.pdf PDF
Attachment H - DWG_23of42.pdf PDF
Attachment H - DWG_35of42.pdf PDF
Attachment H - DWG_08of42.pdf PDF
Attachment H - DWG_10of42.pdf PDF
Show 40 more

Latest 50 of 85 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W

XW

A1

A1

A

A

A

A

B1

F

F

EM

A

E

C D

D

UP

EM

DOWN

D F F

J

DOWN

UP

G107

BALCONY

G105

KITCHEN

G104

DINING

G103

LIVING ROOM

G100

CIRCULATION

G102

FAMILY G101

HALF BATH

XW

G1 G1

G1 G1

A

UP

A

EM

A

H

H1

H

UP

UP

H

H H: 2.300 m

H H: 2.300 m

G1 G1

G4

G002

MECHANICAL ROOM G001

MAIN ENTRY

G006

FOYER

G003

LAUNDRY

G004

STORAGE

G008

CLOSET

G000

ENTRY

XW

A1 A1

A

B2

B1

A1

A

B1

B1

A A

EM

A

B2

DOWN

A A

EM

DOWN

26.252

26.252

G202

BEDROOM 2

G201

BEDROOM 3

G203

BATHROOM 2

G200

CIRCULATION

G204

MASTER BEDROOM

G206

MASTER CLOSET

G205

MASTER BATHROOM

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

2 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

1669111

N62470-20-D-0008

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A

TH

U S E R

SEK

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:0 :2

B

IM

B P A M E R

V ic e n za p h a s e

IV

A F H P

TH

E b u ild in g .r vt

DAA JCBMVA

3B R

T H

G R

O U

N D

, F

IR

S T

A N

D S

E C

O N

D F

LO

O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

T H

P

IA

N O

T E

R R

A , P

R

IM

O E

EL420

14127098

D A A

SCALE 1 : 50

A2

3BR TH FIRST FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR TH PIANO PRIMO

SCALE 1 : 50

A1

3BR TH GROUND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR TH PIANO TERRA

SCALE 1 : 50

A3

3BR TH SECOND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR TH PIANO SECONDO

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 TO EL503 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 A EL503 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP630 TO EP645 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP630 A

EP645 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN

APARTMENT BUILDINGS GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICHE E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE DEGLI

APPARTAMENTI, IN CONFORMITÀ ALLE NORME CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 20 MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 20 MM MINIMO.

8. INTERIOR LIGHTING IS FED FROM: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,

TH 4BR AND TH 3BR), EP-12 (AP 4BR, AP 4BR ABA). OUTDOOR LIGHTING IS FED

FROM: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR). / L'ILLUMINAZIONE INTERNA È

ALIMENTATA DAI QUADRI ELETTRICI: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,

TH 4BR), EP-12 (AP 4BR, AP 4BR ABA). L'ILLUMINAZIONE ESTERNA È ALIMENTATA

DAI QUADRI ELETTRICI: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR).

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.252 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. /

INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE /

SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE PIANTE

ENERGIA ED IMPIANTI MECCANICI PER LA SUA POSIZIONE.

ABC

D

H005

GARAGE

H002

MECHANICAL ROOM

H001

ENTRY

H007

STORAGE

H006

FOYER

H003

LAUNDRY

G1

A

G1

G1 G1

G1

EM

A

UP

H

H1

H

H

UP

UP

A

H

G1

G4

H

ABC

D

H103

LIVING ROOM

H105

KITCHEN

H104

DINING

H107

BALCONY

H102

FAMILY

H106

HALF BATH

H101

CIRCULATION

A1

A

B1

A

A A A1

C

D D

E

F F F F

EM

A

EM

DOWN

UP

B2

J

UP

DOWN

ABC

D

H204

MASTER BEDROOM

H202

BEDROOM 2

H200

CIRCULATION

H201

BEDROOM 3

H200

CIRCULATION

H206

MASTER CLOSET

H205

MASTER BATHROOM

H207

LINEN CLOSET

A

A1

A

B2

B1

A

A

AA

A1

A

B2

B1

A1

EM

DOWN

DOWN

26.252

26.252

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

2 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

1669111

N62470-20-D-0008

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A

TH

U S E R

SEK

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:0 :3

B

IM

B P A M E R

V ic e n za p h a s e

IV

A F H P

TH

E b u ild in g .r vt

DAA JCBMVA

3B R

C O

R N

E R

T H

G R

O U

N D

, F

IR

S T

A N

D S

E C

O N

D L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A Z

IO

N

E

B R

C O

R N

E R

T H

P

IA

N O

T E

R R

A , 1

º E

º

EL421

14127099

D A A

SCALE 1 : 50

C1

3BR CORNER TH GROUND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR CORNER TH PIANO TERRA

SCALE 1 : 50

C3

3BR CORNER TH FIRST FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR CORNER TH PIANO PRIMO

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 TO EL503 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 A EL503 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP630 TO EP645 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP630 A

EP645 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN

APARTMENT BUILDINGS GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICHE E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE DEGLI

APPARTAMENTI, IN CONFORMITÀ ALLE NORME CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 20 MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 20 MM MINIMO.

8. INTERIOR LIGHTING IS FED FROM: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,

TH 4BR AND TH 3BR), EP-12 (AP 4BR, AP 4BR ABA). OUTDOOR LIGHTING IS FED

FROM: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR). / L'ILLUMINAZIONE INTERNA È

ALIMENTATA DAI QUADRI ELETTRICI: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,

TH 4BR), EP-12 (AP 4BR, AP 4BR ABA). L'ILLUMINAZIONE ESTERNA È ALIMENTATA

DAI QUADRI ELETTRICI: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR).

SCALE 1 : 50

A1

3BR CORNER TH SECOND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR CORNER TH PIANO SECONDO

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.252 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. /

INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE /

V U

UP

UP

UP

UP

UP

UP

G1 G1

G1 G1

G1

A

A

A

EM

G4

G1 G1

H

H

H1

H

H

I005

GARAGE

I000

ENTRY

I007

CLOSET

I002

LAUNDRY

I008

FOYER

I003

MECHANICAL ROOM I001

MAIN ENTRY

V U

UP

A1

A1

A

A

A

A

EM

C

D

D

D E

A

EM

A

A

B2 F

G3

F F

F

F

F

F

B1

J

F

UP

DOWN

I107

BALCONY

I104

DINING

I105

KITCHEN

I103

LIVING ROOM

I106

PANTRY

I100

CIRCULATION

I102

FAMILY

I101

HALF BATH

V U

A1

A1

A

A

A

A A A

A A

A

B2

B2

A1 A1

EM

EM

DOWN

EM

DOWN

DOWN

B1

B1

B1

26.252

26.252

I205

MASTER BEDROOM

I206

BEDROOM 4

I201

BEDROOM 3

I202

BEDROOM 2

I204

MASTER CLOSET

I207

BATHROOM 2

I200

CIRCULATION

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

2 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

1669111

N62470-20-D-0008

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A

TH

U S E R

SEK

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:4 :1

B

IM

B P A M E R

V ic e n za p h a s e

IV

A F H P

TH

E b u ild in g .r vt

DAA JCBMVA

4B R

T H

G R

O U

N D

, F

IR

S T

A N

D S

E C

O N

D F

LO

O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

T H

P

IA

N O

T E

R R

A , P

R

IM

O E

EL422

14127100

D A A

SCALE 1 : 50

A1

4BR TH GROUND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 4BR TH PIANO TERRA

SCALE 1 : 50

A2

4BR TH FIRST FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 4BR TH PIANO PRIMO

SCALE 1 : 50

A3

4BR TH SECOND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 4BR TH PIANO SECONDO

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 TO EL503 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 A EL503 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP630 TO EP645 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP630 A

EP645 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN

APARTMENT BUILDINGS GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICHE E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE DEGLI

APPARTAMENTI, IN CONFORMITÀ ALLE NORME CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 20 MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 20 MM MINIMO.

8. INTERIOR LIGHTING IS FED FROM: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,

TH 4BR AND TH 3BR), EP-12 (AP 4BR, AP 4BR ABA). OUTDOOR LIGHTING IS FED

FROM: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR). / L'ILLUMINAZIONE INTERNA È

ALIMENTATA DAI QUADRI ELETTRICI: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,

TH 4BR), EP-12 (AP 4BR, AP 4BR ABA). L'ILLUMINAZIONE ESTERNA È ALIMENTATA

DAI QUADRI ELETTRICI: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR).

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.252 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. /

INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE /

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

A. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF

BUILDINGS. /

VEDERE PIANTE ARCHITETTONICHE E CIVILI PER UBICAZIONE DEGLI

EDIFICI.

B. SEE INTERIOR LIGHTING FIXTURE SCHEDULE EL601 AND ‘INTERIOR

LIGHTING FIXTURE DETAILS’ FOR SPECIFICATION REQUIREMENTS OF

FIXTURES INDICATED ON THIS SHEET. /

VEDERE L'ABACO DEGLI APPARECCHI DI ILLUMINAZIONE DI INTERNI

EL601 E PARTICOLARI APPARECCHI ILLUMINAZIONE DA INTERNO PER

SPECIFICHE/REQUISITI DEGLI APPARECCHI INDICATI IN QUESTA

TAVOLA.

C. SEE PANELBOARD SCHEDULES (EP652) FOR CIRCUIT DESIGNATIONS

INDICATED ON THIS SHEET. /

VEDERE L'ABACO DEI QUADRI DI DISTRIBUZIONE (EP652) NELLE

ABITAZIONI PER LE DESIGNAZIONI DI TUTTI I CIRCUITI INDICATI IN

QUESTO FOGLIO.

D. SEE SHEETS E-001, E-002 AND E-003 FOR ABBREVIATIONS, LEGENDS

AND NOTES. /

VEDERE I FOGLI E-001, E-002 E E-003 PER ABBREVIAZIONI, LEGENDE E

NOTE

E. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. PROVIDE

CIRCUITRY ROUTING CONCEALED EXCEPT IN GARAGES IN

ACCORDANCE WITH CEI NORMS. /

GLI SCHEMI DEI CABLAGGI DEI CIRCUITI ELETTRICI SONO SCHEMATICI.

FORNIRE IN OPERA IL PERCORSO DELLA CIRCUITERIA NASCOSTA

ECCETTO NELLE AUTORIMESSE IN CONFORMITA' CON LE NORME CEI.

F. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND

FINISHED AREAS. /

SE NON ALTRIMENTI INDICATO, POSARE LA CIRCUITERIA INCASSATA

NELLE UNITA' RESIDENZIALI, AREE NUCLEO/SCALA DEGLI

APPARTAMENTI

G. ALL CONDUIT RIGID OR FLEXIBLE WILL BE (1) ⌀20MM MINIMUM. /

TUTTI I TUBI PORTACAVO RIGIDI O FLESSIBILI DOVRANNO ESSERE (1)

MINIMO 20MM DI DIAMETRO

H. REFER TO MECHANICAL SHEETS FOR INFORMATION. / FARE

RIFERIMENTO ALLE TAVOLE MECCANICHE PER INDICAZIONII SUL

SEZIONATORE.

I. LIGHTING IS FED FROM: EP-11. / L'ILLUMINAZIONE E ALIMENTATA DAI

QUADRI ELECTRICI: EP-11.

J. SEE SHEET I-430 FOR EXACT LIGHTING FIXTURE LOCATIONS. /VEDERE

I FOGLI I-430 PER LE POSIZIONI ESATTE DEGLI APPARECCHI DI

ILLUMINAZIONE.

+2540mm AFG

+3240mm AFG

E

C

A

B1

D

H

A1 A1

A

F

F

H

H

H

A

G1

A

A

EM

F B2

G1

G3

26.001

26.002

26.003

26.005

E

UP

EP

ENTRY

K001

FAMILY

K002

FOYER

K013

CLOSET

K014

HALF BATH

K003

MECHANICAL

K004

GARAGE

K005

STORAGE

K012

KITCHEN

K009

LIVING

K011

DINING

K010

+2540mm AFG

F

+2700mm AFG

TO

LIGHT

ABOVE

KEYPLAN / PIANO STRATEGICO

PLAN

NORTH

0 421 3 5

SCALE: 1:50

M A

R K

D A T E

D E

S C

R

IP

T

IO

N

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

C

T

1669111

N62470-20-D-0008

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:0 :3

A M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P O H E h o u s in g .r v t

GDA BWYSHA

O H

B U

IL

D

IN

G

G

R O

U N

D F

L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A

IL

L U

M

IN

A Z

IO

N

E O

H B

U

IL

D

IN

G

P

IA

N

O T

E R

R A

E P

R

IM

O

EL430

14127101

G D A

26.001. SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN.

REFER TO POWER AND MECHANICAL PLANS FOR LOCATION. /

INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE

SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE

PIANTE ENERGIA ED IMPIANTI MECCANICI PER LA SUA

POSIZIONE.

26.002. CONDUIT AND JUNCTION BOX FOR CEILING FAN EMBEDDED

IN SLAB ABOVE ENT K001. / CONDOTTO E SCATOLA DI

GIUNZIONE PER VENTOLA A SOFFITTO INSERITI IN LASTRA

SOPRA ENT K001.

26.003. CONDUIT AND JUNCTION BOX FOR LIGHT EMBEDDED IN SLAB

ABOVE ENT K001. / CONDOTTO E SCATOLA DI GIUNZIONE PER

ILLUMINAZONE INSERITI IN LASTRA SOPRA ENT K001.

26.004. SWITCHES FOR CEILING FAN LIGHT. / INTERRUTTORI PER

ILLUMINAZIONE VENTOLA A SOFFITTO

26.005. SWITCH FOR CEILING FAN MOTOR. / INTERRUTTORE PER

MOTORE VENTOLA A SOFFITTO.

SHEET KEYNOTES: / NOTE CHIAVE

DEL DISEGNO

SCALE: 1 : 50

A1

OH BUILDING 20160 GROUND FLOOR LIGHTING PLAN / PIANTA ILLUMINAZIONE OH BUILDING 20160 PIANO TERRA E PRIMO

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

A. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF

BUILDINGS. /

VEDERE PIANTE ARCHITETTONICHE E CIVILI PER UBICAZIONE DEGLI

EDIFICI.

B. SEE INTERIOR LIGHTING FIXTURE SCHEDULE EL601 AND ‘INTERIOR

LIGHTING FIXTURE DETAILS’ FOR SPECIFICATION REQUIREMENTS OF

FIXTURES INDICATED ON THIS SHEET. /

VEDERE L'ABACO DEGLI APPARECCHI DI ILLUMINAZIONE DI INTERNI

EL601 E PARTICOLARI APPARECCHI ILLUMINAZIONE DA INTERNO PER

SPECIFICHE/REQUISITI DEGLI APPARECCHI INDICATI IN QUESTA

TAVOLA.

C. SEE PANELBOARD SCHEDULES (EP652) FOR CIRCUIT DESIGNATIONS

INDICATED ON THIS SHEET. /

VEDERE L'ABACO DEI QUADRI DI DISTRIBUZIONE (EP652) NELLE

ABITAZIONI PER LE DESIGNAZIONI DI TUTTI I CIRCUITI INDICATI IN

QUESTO FOGLIO.

D. SEE SHEETS E-001, E-002 AND E-003 FOR ABBREVIATIONS, LEGENDS

AND NOTES. /

VEDERE I FOGLI E-001, E-002 E E-003 PER ABBREVIAZIONI, LEGENDE E

NOTE

E. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. PROVIDE

CIRCUITRY ROUTING CONCEALED EXCEPT IN GARAGES IN

ACCORDANCE WITH CEI NORMS. /

GLI SCHEMI DEI CABLAGGI DEI CIRCUITI ELETTRICI SONO SCHEMATICI.

FORNIRE IN OPERA IL PERCORSO DELLA CIRCUITERIA NASCOSTA

ECCETTO NELLE AUTORIMESSE IN CONFORMITA' CON LE NORME CEI.

F. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND

FINISHED AREAS. /

SE NON ALTRIMENTI INDICATO, POSARE LA CIRCUITERIA INCASSATA

NELLE UNITA' RESIDENZIALI, AREE NUCLEO/SCALA DEGLI

APPARTAMENTI

G. ALL CONDUIT RIGID OR FLEXIBLE WILL BE (1) ⌀20MM MINIMUM. /

TUTTI I TUBI PORTACAVO RIGIDI O FLESSIBILI DOVRANNO ESSERE (1)

MINIMO 20MM DI DIAMETRO

H. REFER TO MECHANICAL SHEETS FOR INFORMATION. / FARE

RIFERIMENTO ALLE TAVOLE MECCANICHE PER INDICAZIONII SUL

SEZIONATORE.

I. LIGHTING IS FED FROM: EP-11. / L'ILLUMINAZIONE E ALIMENTATA DAI

QUADRI ELECTRICI: EP-11.

J. SEE SHEET I-430 FOR EXACT LIGHTING FIXTURE LOCATIONS. /VEDERE

I FOGLI I-430 PER LE POSIZIONI ESATTE DEGLI APPARECCHI DI

ILLUMINAZIONE.

B2

A

A

A A

B1

A

A

B1

A1

A1

LAUNDRY

K102

BEDROOM 2

K104

MASTER BATH

K105

MASTER

BEDROOM

K106

MASTER CLOSET

K107

CIRCULATION

K100BEDROOM 3

K108

BEDROOM 4

K101

A1

A1

A A

G4

26.001 A

EM

EM

A

B2

BATHROOM

K103

B2

26.002

26.002

TO SWITCH

BELOW

DOWN

KEYPLAN / PIANO STRATEGICO

PLAN

NORTH

0 421 3 5

SCALE: 1:50

M A

R K

D A T E

D E

S C

R

IP

T

IO

N

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:0 :3

A M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P O H E h o u s in g .r v t

GDA BWYSHA

O H

B U

IL

D

IN

G

F

IR

S

T F

L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E

O H

B U

IL

D

IN

G

P

IA

N

O P

R

IM

O

EL431

14127102

G D A

26.001. PROVIDE SWITCH FOR LIGHT FIXTURE ABOVE ACCESS

PANEL. / FORNIRE IN OPERA L'INTERRUTTORE PER

APPARECCHIO ILLUMINANTE AL DI SOPRA DEL PANNELLO DI

ACCESSO.

26.002. SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN.

REFER TO POWER AND MECHANICAL PLANS FOR LOCATION. /

INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE

SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE

PIANTE ENERGIA ED IMPIANTI MECCANICI PER LA SUA

POSIZIONE.

SHEET KEYNOTES: / NOTE CHIAVE

DEL DISEGNO

SCALE: 1 : 50

A1

OH BUILDING 20160 FIRST FLOOR LIGHTING PLAN / PIANTA ILLUMINAZIONE OH BUILDING 20160 PIANO PRIMO

A CB

GARAGE

a

G5

ATTIC

a a a a a aa

G5

G5

G5 G5

G5

W1

W1 W1

MDP- 11

MDP- 18

LANDSCAPE LIGHTING

SEE SHEET ES402

LANDSCAPE LIGHTING

SEE SHEET ES402

G5

E L4

E

L4

TO W1

FIXTURE

TO B5

FIXTURE IN

CORRIDOR

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :3

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A A

G R

O U

N D

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A R

E A

A P

IA

N

O T

E R

R A

EL442

14127103

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20060 GROUND FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE TERRA

C D F G H J K

KITCHEN

BEDROOM

CLOSET

BATH

CLOSET

POWDER ROOM

MECH

ENTRY

MUD ROOM

GARAGE

VERANDA

DINING

LIVING

PANTRY

ADMIN

B8

B8

B9

B9

B9

B5

B5

B5 B5

B11

B5

B5

B5

B5

B5

B5

B5 B5

B5

B5

B5

B7

G4

G1

MOUNT AT

750 MM AFF

B5

CF

b b b c c c d d z y y f f f f g g g g g g g g g k k aa j(2) j

UC3 BELOW

EACH SHELF

aa h f m m m m l z g l j x x e e c p p p p n o no n o o o o o o o q q q q q q q q q CFs q s w v u t u v t u u u u u u u u v w u v cc

B5

B5

B5

B5

G4 o

B8 B8

B8

B8 B8 B8 h i gh

B5

B5

B5

B5

B5

B5 B5 B5

B3 B5

B5

B5B5

B5 B5

B5

B5

B5

B5

B9

B9

B9

B9

B9

B5

B5

B5 i i

B5 B5 u u

B5

B5 i p p p p

Q2

Q2 Q2 Q2 o o

B8 B8 q gg gggggggggggg gg gg gg gg gg gg

B9 g B5

B5 g

B5 g g

B5 o o

B8 B8 q

B9

B9 q q q q s q

B9

B10

B10

B9 s

B9

B9 s B10

B10 s

B12 B12

CF1

B7

B7

B7 B7

B7

B7 B7 B7 B7 B7

L2

L1

P3

P3

P2

P6

P1

P6

P5

P6

P6 P6

W1

W1 W1 W1 W1

W1 W1

W1

W1

W2

W2

B12

U1

U2

U1

U3

U4

CIRCUIT

MDP-11

CIRCUIT

MDP-18

LANDSCAPE LIGHTING

SEE SHEET ES402

LANDSCAPE LIGHTING

SEE SHEET ES402

LANDSCAPE LIGHTING

SEE SHEET ES402

E L4

E

L4 g g

B5

B5

26.507

26.507

26.507

E

W1 W1

TO Q2 ON EL445 /

A Q2 SU EL445

CF

PH 26.515

t t t y y y y y zz zz zz zzzz zz xxxx yy yy yy yy yy xx xx xx

W1 j

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :3

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A B

G R

O U

N D

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A R

E A

B P

IA

N

O T

E R

R A

EL443

14127104

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20060 GROUND FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE TERRA

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE

CON TEMPORIZZATORE PER ACCENSIONE /

SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE PIANTE

ENERGIA ED IMPIANTI MECCANICI PER LA SUA POSIZIONE.

26.515 LINE VOLTAGE INDOOR PHOTOCELL SENSOR FOR ON/OFF CONTROL OF Q2

STEP LIGHTS. CONTROL MUST BE ON AT DUSK, OFF AT DAWN - BASED ON

OUTDOOR LIGHT LEVEL. PHOTOCELL MUST BE WIRED IN SERIES WITH

LIGHT SWITCH FOR MANUAL OVERRIDE. LOCATE PHOTOCELL FLUSH

MOUNTED WITHIN THE WINDOW HEAD. INSTALL PER MANUFACTURER'S

RECOMMENDATIONS. / SENSORE A FOTOCELLULA DA INTERNO DELLA

TENSIONE DI LINEA PER IL CONTROLLO ON/OFF DI LUCI PASSO Q2. IL

COMANDO DEVE ESSERE ACCESO AL TRAMONTO, SPENTO ALL'ALBA - IN

BASE AL LIVELLO DI LUCE ESTERNA. LA FOTOCELLULA DEVE ESSERE

CABLATA IN SERIE CON INTERRUTTORE LUCE PER L'AZIONAMENTO

MANUALE. INDIVIDUARE LA FOTOCELLULA MONTATA A INCASSO

ALL'INTERNO DELLA TESTA DELLA FINESTRA. INSTALLARE SECONDO LE

RACCOMANDAZIONI DEL PRODUTTORE.

A C DB

B

G5 G5

G5

CIRCUIT MDP-11

E L4

E

L4

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :3

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A A

F

IR

S T

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A

R E

A A

P

IA

N O

P R

IM

O

EL444

14127105

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20060 FIRST FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE PRIMO

D F G H J K

BEDROOM 2

BEDROOM 1

BATH

LAUNDRY

FAMILY ROOM

CLOSET

MASTER BR

MASTER BATH

CLOSET/SAFE ROOM

B11

B7 B11 B7

B7 B7

B7

B7

B7 B7

B7

MOUNT AT 750 MM

AFF

MOUNT AT 750 MM

AFF

MOUNT AT 750

MM AFF

EM

EM

CF

CF

CF

cc cc cc cc ccdd dd dd dd dd dd ee ee ee eeee eeee eeee eeee ee ff ff ff ff ff ff

B7

B7

B7

B7

B7 B7

B7 B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7 bb bb B7

B7

B7 cc

B7 B7

B7

B7 B7

B7

CF

CF

L3

L3

P8

P4

E L4

E

L4

B7 B7B7

26.507 26.50726.507

E

Q2 Q2 Q2 Q2 Q2

FROM Q2 ON EL443 /

DA Q2 SU EL443

CF

CF

CF

CF

CF

B7 yyyyy

B7 zz zz zz zz zz zz zzzz zz zz zz zz zz zz

MDP- 35

zz zz zzzz zz zz hh hh hh gg gg ii ii ii jj jj jj jj kk kk ll ll ll mm mmnn nn

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :3

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A B

F

IR

S T

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A

R E

A B

P

IA

N O

P R

IM

O

EL445

14127106

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20060 FIRST FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE PRIMO

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE

CON TEMPORIZZATORE PER ACCENSIONE /

CB

G5

G5

GARAGE

MUD ROOM

ENTRY

b a

ATTIC

a a a a a a a

G5

G5

G5 G5 G5

W1 W1

W1

MDP- 11

MDP- 18

LANDSCAPE LIGHTING

SEE SHEET ES401

E L4

E

L4

A

TO W1

FIXTURE

TO B5

FIXTURE IN

CORRIDOR

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :0

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A A

G R

O U

N D

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A R

E A

A P

IA

N

O T

E R

R A

EL446

14127107

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20070 GROUND FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA

KJHGFEDC

B9

B5

B5

B5

B5

B5

B5

B5

B5

B5

B5

B5B5

G4

B5

B5

G1

MUD ROOM

ENTRY

MECH

STORAGE

PANTRY

KITCHEN

VERANDA

DINING

LIVING

FOYER

BATH

BEDROOM

CLOSET

POWDER ROOM

CLOSET

B5

MOUNT AT

750 MM AFF

b b f f f f h g g g g g gg g g h g jj k k m c c c c d d l l b e e no n o o o o o o oo p p p q s q q s t u v t v u v w w u u u u u v gh cc

B5

B7

B5

B5

B5 B5

B5

B5

B5 i

B5

B9

B9

B9

B9 B9

B9 B9

B9

B9

B10

B5

B5

B5

B5

B5B5 u

B5

B5

CF

B5

B11

B5 B5

B5

G4

B12 i i u u u uB5 B5

B5 B5 i m

B12 B12 p p B9

B9 o o cc cc cc cccc cc cc cccc cc

Q2

Q2 Q2 Q2 dd dd g

B5 g g g

B5

B5 B5 B5 q s q q B9

B9 q

B9

B10 s

B10 s

B10 s

B9 s

B9 s

B7

B7

B7

B7

B7

B7

B7

B7

L2

L1

CF1

P3

P3

P2

P6

P6

P6

P5

W1

W1

W1W1

W1

W1

W2

W2

U1

U1

U1

U2g

W1 W1

CIRCUIT

MDP-11

CIRCUIT MDP-18

LANDSCAPE LIGHTING

SEE SHEET ES401

LANDSCAPE LIGHTING

SEE SHEET ES401

E L4

E

L4 g

B5

B5 m m

B5

26.507

26.507

26.507

TO Q2 ON EL449 /

A Q2 SU EL449

W1 W1

PH 26.515

CF

CF

P1 no y y y y y zz zz zz zz zz zzxx xxyy yy yy yy yy xx xx xx

W1

W1 j pp pp pp pp

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :0

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A B

G R

O U

N D

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A R

E A

B P

IA

N

O T

E R

R A

EL447

14127108

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20070 GROUND FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE

CON TEMPORIZZATORE PER ACCENSIONE /

SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE PIANTE

ENERGIA ED IMPIANTI MECCANICI PER LA SUA POSIZIONE.

26.515 LINE VOLTAGE INDOOR PHOTOCELL SENSOR FOR ON/OFF CONTROL OF Q2

STEP LIGHTS. CONTROL MUST BE ON AT DUSK, OFF AT DAWN - BASED ON

OUTDOOR LIGHT LEVEL. PHOTOCELL MUST BE WIRED IN SERIES WITH

LIGHT SWITCH FOR MANUAL OVERRIDE. LOCATE PHOTOCELL FLUSH

MOUNTED WITHIN THE WINDOW HEAD. INSTALL PER MANUFACTURER'S

RECOMMENDATIONS. / SENSORE A FOTOCELLULA DA INTERNO DELLA

TENSIONE DI LINEA PER IL CONTROLLO ON/OFF DI LUCI PASSO Q2. IL

COMANDO DEVE ESSERE ACCESO AL TRAMONTO, SPENTO ALL'ALBA - IN

BASE AL LIVELLO DI LUCE ESTERNA. LA FOTOCELLULA DEVE ESSERE

CABLATA IN SERIE CON INTERRUTTORE LUCE PER L'AZIONAMENTO

MANUALE. INDIVIDUARE LA FOTOCELLULA MONTATA A INCASSO

ALL'INTERNO DELLA TESTA DELLA FINESTRA. INSTALLARE SECONDO LE

RACCOMANDAZIONI DEL PRODUTTORE.

DCB

G5 G5 G5

CIRCUIT MDP-11

E L4

E

L4

A

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :0

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A A

F

IR

S T

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A

R E

A A

P

IA

N O

P R

IM

O

EL448

14127109

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20070 FIRST FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA

KJHGFEDC

E L4

E

L4

BEDROOM 2

BEDROOM 1

BATH

LAUNDRY

FAMILY ROOM

CLOSET

MASTER BR

MASTER BATH

CLOSET/SAFE ROOM

B11

B7 B11 B7

B7 B7

B7

B7

B7

B7

B7

MOUNT AT 750 MM

AFF

MOUNT AT 750 MM

AFF

MOUNT AT 750 MM

AFF

EM

EM

CF

CF

CF

cc cc cc cc ccdd dd dd dd dd dd ee ee ee eeee ee ee eeee ee ee ee ff ff ff ff ff ff

B7

B7

B7

B7

B7

B7

B7 B7

B7 B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7

B7 B7

B7

B7

B7 bb bb B7

B7

B7 cc

B7 B7 B7

B7

B7

B7

CF

CF

L3

L3

P8

P4B7 B7B7

26.507 26.50726.507

Q2 Q2 Q2 Q2 Q2

FROM Q2 ON EL447 /

DA Q2 SU EL447

CF

CF

CF

CF

CF

y y y y y

B7

B7 zz zz zz zz zz zz zz zz zz zz zz zz zz zz

MDP- 38

zz zz zz zzzz zz ii ii ii hh hh hh gg gg jj jj jj jj kk kk ll ll ll mm mm nn nn

CLOSET

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.

SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508

FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI

DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI

DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A

EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.

5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660

PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI

NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE

ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA

CEI.

7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE

REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO

GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA

DELLA PIANTA DEL SITO ES401.

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A T E

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

KMC

7 DEC 2022

:4 :0

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P G F O Q E h o u s in g .r v t

DKB AJZLAK

G F

O Q

B U

IL

D

IN

G

A

R E

A B

F

IR

S T

F L O

O R

L

IG

H T

IN

G

P L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E G

F O

Q E

D

A

R E

A B

P

IA

N O

P R

IM

O

EL449

14127110

D K B

SCALE 1 : 50

A1

GFOQ BUILDING 20070 FIRST FLOOR PARTIAL LIGHTING PLAN /

PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO

POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE

CON TEMPORIZZATORE PER ACCENSIONE /

CHAIN HUNG LIGHT

FIXTURE, 3000MM, AFF

(TYP) /

APPARECCHIO

ILLUMINANTE SOSPESO A

CATENA,3000MM, AFF

(TIPICO)

K

EM1

EM1

J

K

K

K

K

SP-10

W1

26.052

KEYPLAN / PIANO STRATEGICO

TORINO

PISA

BUILDING LOCATION / POSIZIONE DEL EDIFICIO

SIMILAR BUILDINGS / EDIFICI SIMILI

PLAN

NORTH

0 421 3 5

SCALE: 1:50

M A

R K

D A T E

D E

S C

R

IP

T

IO

N

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A T H

U S E R

SEK

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:0 :0

P M

B

IM

B P A M E R

V ic e n z a p h a s e

IV

A F H P V S E s u b s ta ti o n .r v t

TRC CLWTRC

S U

B S

T A

T

IO

N L

IG

H

T

IN

G P

L A

N

P

IA

N T

A I L L U

M

IN

A Z

IO

N

E S

O T

T O

S T

A Z

IO

N

E

EL491

14127111

T R C

SCALE: 1 : 50

C1

SUBSTATION LIGHTING PLAN / PIANTA

ILLUMINAZIONE SOTTOSTAZIONE

GENERAL NOTES THIS SHEET:/

NOTE GENERALI DI QUESTO FOGLIO:

A. SEE ARCHITECTURAL, ELECTRICAL SITE AND CIVIL PLANS FOR

LOCATIONS AND NAMES OF BUILDINGS. / VEDERE LE PLANIMETRIE

ARCHITETTONICHE, ELETTRICHE E CIVILI PER LE POSIZIONI E I NOMI

DEGLI EDIFICI.

SHEET KEYNOTES: / NOTE CHIAVE

DI QUESTO FOGLIO

26.052 SEE SITE PLAN FOR EXACT LOCATION OF TYPE W1 FIXTURE ON

SUBSTATION BUILDING. / PER LA POSIZIONE ESATTA DELL'APPARECCHIO DI

TIPO W1 SULL'EDIFICIO DELLA SOTTOSTAZIONE, VEDERE LA PLANIMETRIA.

W/T

DT DT

WP

W/T

WP

W /T

W/T

W/T

W/T

W/T

W /T

WP

C1

EL394

B2

EL394

K H: 2.0 m

G1 H: 2.2 m

K H: 2.0 m

K H: 2.0 m

J005

STORAGE ROOM 1

J006

STORAGE ROOM 2

J001

RESTROOM

J002

UTILITY

J003

ELECTRICAL

EP-01

EP-01

EP-01

EP-01

EP-01

EP-01

EP-01

EP-01

26.264

A1

EL394 W4

H: 2.5 m W4

H: 2.5 m

K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1

K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1

26.249

EP26.271

K H: 2.0 m

K H: 2.0 m

H1 H: 2.25 m

H1 H: 2.25 m

H1 H: 2.25 m

H1 H: 2.25 m

26.263

EP-01

K H: 2.0 m

B1 H: 2.04 m

J004

RESTROOM

B1 H: 2.04 m

G1 H: 2.0 m

PAVILION /

PADIGLIONE

BUILDING LOCATION / POSIZIONE DEL EDIFICIO

KEYPLAN / PIANO STRATEGICO

PLAN

NORTH

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE:

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

2 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

1669111

N62470-20-D-0008

CCA/MPO

R. STEPHENS, PE

DPS

AS NOTED

F

IL

E

P A

TH

U S E R

SEK

7 DECEMBER 2022

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.

:4 :2

B

IM

B P A M E R

V ic e n za p h a s e

IV

A F H P P V E p a vi li o…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .