W
XW
A1
A1
A
A
A
A
B1
F
F
EM
A
E
C D
D
UP
EM
DOWN
D F F
J
DOWN
UP
G107
BALCONY
G105
KITCHEN
G104
DINING
G103
LIVING ROOM
G100
CIRCULATION
G102
FAMILY G101
HALF BATH
XW
G1 G1
G1 G1
A
UP
A
EM
A
H
H1
H
UP
UP
H
H H: 2.300 m
H H: 2.300 m
G1 G1
G4
G002
MECHANICAL ROOM G001
MAIN ENTRY
G006
FOYER
G003
LAUNDRY
G004
STORAGE
G008
CLOSET
G000
ENTRY
XW
A1 A1
A
B2
B1
A1
A
B1
B1
A A
EM
A
B2
DOWN
A A
EM
DOWN
26.252
26.252
G202
BEDROOM 2
G201
BEDROOM 3
G203
BATHROOM 2
G200
CIRCULATION
G204
MASTER BEDROOM
G206
MASTER CLOSET
G205
MASTER BATHROOM
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :2
B
IM
B P A M E R
V ic e n za p h a s e
IV
A F H P
TH
E b u ild in g .r vt
DAA JCBMVA
3B R
T H
G R
O U
N D
, F
IR
S T
A N
D S
E C
O N
D F
LO
O
R L
IG
H
TI
N
G P
LA
N
P
IA
N
TA
IL
LU
M
IN
A
ZI
O N
E
B R
T H
P
IA
N O
T E
R R
A , P
R
IM
O E
EL420
14127098
D A A
SCALE 1 : 50
A2
3BR TH FIRST FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 3BR TH PIANO PRIMO
SCALE 1 : 50
A1
3BR TH GROUND FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 3BR TH PIANO TERRA
SCALE 1 : 50
A3
3BR TH SECOND FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 3BR TH PIANO SECONDO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR
LIGHTING FIXTURE DETAILS SHEETS EL501 TO EL503 FOR
SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO
CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI
INTERNI EL501 A EL503 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.
5. SEE PANELBOARD SCHEDULES SHEETS EP630 TO EP645 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP630 A
EP645 PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN
APARTMENT BUILDINGS GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE
CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICHE E LE
CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.
FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE DEGLI
APPARTAMENTI, IN CONFORMITÀ ALLE NORME CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 20 MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 20 MM MINIMO.
8. INTERIOR LIGHTING IS FED FROM: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,
TH 4BR AND TH 3BR), EP-12 (AP 4BR, AP 4BR ABA). OUTDOOR LIGHTING IS FED
FROM: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR). / L'ILLUMINAZIONE INTERNA È
ALIMENTATA DAI QUADRI ELETTRICI: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,
TH 4BR), EP-12 (AP 4BR, AP 4BR ABA). L'ILLUMINAZIONE ESTERNA È ALIMENTATA
DAI QUADRI ELETTRICI: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR).
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.252 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. /
INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE /
SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE PIANTE
ENERGIA ED IMPIANTI MECCANICI PER LA SUA POSIZIONE.
ABC
D
H005
GARAGE
H002
MECHANICAL ROOM
H001
ENTRY
H007
STORAGE
H006
FOYER
H003
LAUNDRY
G1
A
G1
G1 G1
G1
EM
A
UP
H
H1
H
H
UP
UP
A
H
G1
G4
H
ABC
D
H103
LIVING ROOM
H105
KITCHEN
H104
DINING
H107
BALCONY
H102
FAMILY
H106
HALF BATH
H101
CIRCULATION
A1
A
B1
A
A A A1
C
D D
E
F F F F
EM
A
EM
DOWN
UP
B2
J
UP
DOWN
ABC
D
H204
MASTER BEDROOM
H202
BEDROOM 2
H200
CIRCULATION
H201
BEDROOM 3
H200
CIRCULATION
H206
MASTER CLOSET
H205
MASTER BATHROOM
H207
LINEN CLOSET
A
A1
A
B2
B1
A
A
AA
A1
A
B2
B1
A1
EM
DOWN
DOWN
26.252
26.252
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :3
B
IM
B P A M E R
V ic e n za p h a s e
IV
A F H P
TH
E b u ild in g .r vt
DAA JCBMVA
3B R
C O
R N
E R
T H
G R
O U
N D
, F
IR
S T
A N
D S
E C
O N
D L
IG
H
TI
N
G P
LA
N
P
IA
N
TA
IL
LU
M
IN
A Z
IO
N
E
B R
C O
R N
E R
T H
P
IA
N O
T E
R R
A , 1
º E
º
EL421
14127099
D A A
SCALE 1 : 50
C1
3BR CORNER TH GROUND FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 3BR CORNER TH PIANO TERRA
SCALE 1 : 50
C3
3BR CORNER TH FIRST FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 3BR CORNER TH PIANO PRIMO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR
LIGHTING FIXTURE DETAILS SHEETS EL501 TO EL503 FOR
SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO
CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI
INTERNI EL501 A EL503 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.
5. SEE PANELBOARD SCHEDULES SHEETS EP630 TO EP645 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP630 A
EP645 PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN
APARTMENT BUILDINGS GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE
CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICHE E LE
CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.
FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE DEGLI
APPARTAMENTI, IN CONFORMITÀ ALLE NORME CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 20 MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 20 MM MINIMO.
8. INTERIOR LIGHTING IS FED FROM: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,
TH 4BR AND TH 3BR), EP-12 (AP 4BR, AP 4BR ABA). OUTDOOR LIGHTING IS FED
FROM: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR). / L'ILLUMINAZIONE INTERNA È
ALIMENTATA DAI QUADRI ELETTRICI: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,
TH 4BR), EP-12 (AP 4BR, AP 4BR ABA). L'ILLUMINAZIONE ESTERNA È ALIMENTATA
DAI QUADRI ELETTRICI: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR).
SCALE 1 : 50
A1
3BR CORNER TH SECOND FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 3BR CORNER TH PIANO SECONDO
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.252 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. /
INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE /
V U
UP
UP
UP
UP
UP
UP
G1 G1
G1 G1
G1
A
A
A
EM
G4
G1 G1
H
H
H1
H
H
I005
GARAGE
I000
ENTRY
I007
CLOSET
I002
LAUNDRY
I008
FOYER
I003
MECHANICAL ROOM I001
MAIN ENTRY
V U
UP
A1
A1
A
A
A
A
EM
C
D
D
D E
A
EM
A
A
B2 F
G3
F F
F
F
F
F
B1
J
F
UP
DOWN
I107
BALCONY
I104
DINING
I105
KITCHEN
I103
LIVING ROOM
I106
PANTRY
I100
CIRCULATION
I102
FAMILY
I101
HALF BATH
V U
A1
A1
A
A
A
A A A
A A
A
B2
B2
A1 A1
EM
EM
DOWN
EM
DOWN
DOWN
B1
B1
B1
26.252
26.252
I205
MASTER BEDROOM
I206
BEDROOM 4
I201
BEDROOM 3
I202
BEDROOM 2
I204
MASTER CLOSET
I207
BATHROOM 2
I200
CIRCULATION
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:4 :1
B
IM
B P A M E R
V ic e n za p h a s e
IV
A F H P
TH
E b u ild in g .r vt
DAA JCBMVA
4B R
T H
G R
O U
N D
, F
IR
S T
A N
D S
E C
O N
D F
LO
O
R L
IG
H
TI
N
G P
LA
N
P
IA
N
TA
IL
LU
M
IN
A
ZI
O N
E
B R
T H
P
IA
N O
T E
R R
A , P
R
IM
O E
EL422
14127100
D A A
SCALE 1 : 50
A1
4BR TH GROUND FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 4BR TH PIANO TERRA
SCALE 1 : 50
A2
4BR TH FIRST FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 4BR TH PIANO PRIMO
SCALE 1 : 50
A3
4BR TH SECOND FLOOR LIGHTING PLAN /
PIANTA ILLUMINAZIONE 4BR TH PIANO SECONDO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR
LIGHTING FIXTURE DETAILS SHEETS EL501 TO EL503 FOR
SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO
CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI
INTERNI EL501 A EL503 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.
5. SEE PANELBOARD SCHEDULES SHEETS EP630 TO EP645 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP630 A
EP645 PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN
APARTMENT BUILDINGS GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE
CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICHE E LE
CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.
FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE DEGLI
APPARTAMENTI, IN CONFORMITÀ ALLE NORME CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 20 MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 20 MM MINIMO.
8. INTERIOR LIGHTING IS FED FROM: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,
TH 4BR AND TH 3BR), EP-12 (AP 4BR, AP 4BR ABA). OUTDOOR LIGHTING IS FED
FROM: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR). / L'ILLUMINAZIONE INTERNA È
ALIMENTATA DAI QUADRI ELETTRICI: EP-11 (AP 3BR, AP 3BR ABA, TH 3BR COR,
TH 4BR), EP-12 (AP 4BR, AP 4BR ABA). L'ILLUMINAZIONE ESTERNA È ALIMENTATA
DAI QUADRI ELETTRICI: EP-18 (TH 3BR COR, TH 4BR AND TH 5BR).
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.252 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. /
INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE /
GENERAL NOTES THIS SHEET: /
NOTE GENERALI DI QUESTO FOGLIO
A. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF
BUILDINGS. /
VEDERE PIANTE ARCHITETTONICHE E CIVILI PER UBICAZIONE DEGLI
EDIFICI.
B. SEE INTERIOR LIGHTING FIXTURE SCHEDULE EL601 AND ‘INTERIOR
LIGHTING FIXTURE DETAILS’ FOR SPECIFICATION REQUIREMENTS OF
FIXTURES INDICATED ON THIS SHEET. /
VEDERE L'ABACO DEGLI APPARECCHI DI ILLUMINAZIONE DI INTERNI
EL601 E PARTICOLARI APPARECCHI ILLUMINAZIONE DA INTERNO PER
SPECIFICHE/REQUISITI DEGLI APPARECCHI INDICATI IN QUESTA
TAVOLA.
C. SEE PANELBOARD SCHEDULES (EP652) FOR CIRCUIT DESIGNATIONS
INDICATED ON THIS SHEET. /
VEDERE L'ABACO DEI QUADRI DI DISTRIBUZIONE (EP652) NELLE
ABITAZIONI PER LE DESIGNAZIONI DI TUTTI I CIRCUITI INDICATI IN
QUESTO FOGLIO.
D. SEE SHEETS E-001, E-002 AND E-003 FOR ABBREVIATIONS, LEGENDS
AND NOTES. /
VEDERE I FOGLI E-001, E-002 E E-003 PER ABBREVIAZIONI, LEGENDE E
NOTE
E. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. PROVIDE
CIRCUITRY ROUTING CONCEALED EXCEPT IN GARAGES IN
ACCORDANCE WITH CEI NORMS. /
GLI SCHEMI DEI CABLAGGI DEI CIRCUITI ELETTRICI SONO SCHEMATICI.
FORNIRE IN OPERA IL PERCORSO DELLA CIRCUITERIA NASCOSTA
ECCETTO NELLE AUTORIMESSE IN CONFORMITA' CON LE NORME CEI.
F. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN
RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND
FINISHED AREAS. /
SE NON ALTRIMENTI INDICATO, POSARE LA CIRCUITERIA INCASSATA
NELLE UNITA' RESIDENZIALI, AREE NUCLEO/SCALA DEGLI
APPARTAMENTI
G. ALL CONDUIT RIGID OR FLEXIBLE WILL BE (1) ⌀20MM MINIMUM. /
TUTTI I TUBI PORTACAVO RIGIDI O FLESSIBILI DOVRANNO ESSERE (1)
MINIMO 20MM DI DIAMETRO
H. REFER TO MECHANICAL SHEETS FOR INFORMATION. / FARE
RIFERIMENTO ALLE TAVOLE MECCANICHE PER INDICAZIONII SUL
SEZIONATORE.
I. LIGHTING IS FED FROM: EP-11. / L'ILLUMINAZIONE E ALIMENTATA DAI
QUADRI ELECTRICI: EP-11.
J. SEE SHEET I-430 FOR EXACT LIGHTING FIXTURE LOCATIONS. /VEDERE
I FOGLI I-430 PER LE POSIZIONI ESATTE DEGLI APPARECCHI DI
ILLUMINAZIONE.
+2540mm AFG
+3240mm AFG
E
C
A
B1
D
H
A1 A1
A
F
F
H
H
H
A
G1
A
A
EM
F B2
G1
G3
26.001
26.002
26.003
26.005
E
UP
EP
ENTRY
K001
FAMILY
K002
FOYER
K013
CLOSET
K014
HALF BATH
K003
MECHANICAL
K004
GARAGE
K005
STORAGE
K012
KITCHEN
K009
LIVING
K011
DINING
K010
+2540mm AFG
F
+2700mm AFG
TO
LIGHT
ABOVE
KEYPLAN / PIANO STRATEGICO
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A T E
D E
S C
R
IP
T
IO
N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
C
T
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :3
A M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P O H E h o u s in g .r v t
GDA BWYSHA
O H
B U
IL
D
IN
G
G
R O
U N
D F
L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A
IL
L U
M
IN
A Z
IO
N
E O
H B
U
IL
D
IN
G
P
IA
N
O T
E R
R A
E P
R
IM
O
EL430
14127101
G D A
26.001. SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN.
REFER TO POWER AND MECHANICAL PLANS FOR LOCATION. /
INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE
SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE
PIANTE ENERGIA ED IMPIANTI MECCANICI PER LA SUA
POSIZIONE.
26.002. CONDUIT AND JUNCTION BOX FOR CEILING FAN EMBEDDED
IN SLAB ABOVE ENT K001. / CONDOTTO E SCATOLA DI
GIUNZIONE PER VENTOLA A SOFFITTO INSERITI IN LASTRA
SOPRA ENT K001.
26.003. CONDUIT AND JUNCTION BOX FOR LIGHT EMBEDDED IN SLAB
ABOVE ENT K001. / CONDOTTO E SCATOLA DI GIUNZIONE PER
ILLUMINAZONE INSERITI IN LASTRA SOPRA ENT K001.
26.004. SWITCHES FOR CEILING FAN LIGHT. / INTERRUTTORI PER
ILLUMINAZIONE VENTOLA A SOFFITTO
26.005. SWITCH FOR CEILING FAN MOTOR. / INTERRUTTORE PER
MOTORE VENTOLA A SOFFITTO.
SHEET KEYNOTES: / NOTE CHIAVE
DEL DISEGNO
SCALE: 1 : 50
A1
OH BUILDING 20160 GROUND FLOOR LIGHTING PLAN / PIANTA ILLUMINAZIONE OH BUILDING 20160 PIANO TERRA E PRIMO
GENERAL NOTES THIS SHEET: /
NOTE GENERALI DI QUESTO FOGLIO
A. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF
BUILDINGS. /
VEDERE PIANTE ARCHITETTONICHE E CIVILI PER UBICAZIONE DEGLI
EDIFICI.
B. SEE INTERIOR LIGHTING FIXTURE SCHEDULE EL601 AND ‘INTERIOR
LIGHTING FIXTURE DETAILS’ FOR SPECIFICATION REQUIREMENTS OF
FIXTURES INDICATED ON THIS SHEET. /
VEDERE L'ABACO DEGLI APPARECCHI DI ILLUMINAZIONE DI INTERNI
EL601 E PARTICOLARI APPARECCHI ILLUMINAZIONE DA INTERNO PER
SPECIFICHE/REQUISITI DEGLI APPARECCHI INDICATI IN QUESTA
TAVOLA.
C. SEE PANELBOARD SCHEDULES (EP652) FOR CIRCUIT DESIGNATIONS
INDICATED ON THIS SHEET. /
VEDERE L'ABACO DEI QUADRI DI DISTRIBUZIONE (EP652) NELLE
ABITAZIONI PER LE DESIGNAZIONI DI TUTTI I CIRCUITI INDICATI IN
QUESTO FOGLIO.
D. SEE SHEETS E-001, E-002 AND E-003 FOR ABBREVIATIONS, LEGENDS
AND NOTES. /
VEDERE I FOGLI E-001, E-002 E E-003 PER ABBREVIAZIONI, LEGENDE E
NOTE
E. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. PROVIDE
CIRCUITRY ROUTING CONCEALED EXCEPT IN GARAGES IN
ACCORDANCE WITH CEI NORMS. /
GLI SCHEMI DEI CABLAGGI DEI CIRCUITI ELETTRICI SONO SCHEMATICI.
FORNIRE IN OPERA IL PERCORSO DELLA CIRCUITERIA NASCOSTA
ECCETTO NELLE AUTORIMESSE IN CONFORMITA' CON LE NORME CEI.
F. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN
RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND
FINISHED AREAS. /
SE NON ALTRIMENTI INDICATO, POSARE LA CIRCUITERIA INCASSATA
NELLE UNITA' RESIDENZIALI, AREE NUCLEO/SCALA DEGLI
APPARTAMENTI
G. ALL CONDUIT RIGID OR FLEXIBLE WILL BE (1) ⌀20MM MINIMUM. /
TUTTI I TUBI PORTACAVO RIGIDI O FLESSIBILI DOVRANNO ESSERE (1)
MINIMO 20MM DI DIAMETRO
H. REFER TO MECHANICAL SHEETS FOR INFORMATION. / FARE
RIFERIMENTO ALLE TAVOLE MECCANICHE PER INDICAZIONII SUL
SEZIONATORE.
I. LIGHTING IS FED FROM: EP-11. / L'ILLUMINAZIONE E ALIMENTATA DAI
QUADRI ELECTRICI: EP-11.
J. SEE SHEET I-430 FOR EXACT LIGHTING FIXTURE LOCATIONS. /VEDERE
I FOGLI I-430 PER LE POSIZIONI ESATTE DEGLI APPARECCHI DI
ILLUMINAZIONE.
B2
A
A
A A
B1
A
A
B1
A1
A1
LAUNDRY
K102
BEDROOM 2
K104
MASTER BATH
K105
MASTER
BEDROOM
K106
MASTER CLOSET
K107
CIRCULATION
K100BEDROOM 3
K108
BEDROOM 4
K101
A1
A1
A A
G4
26.001 A
EM
EM
A
B2
BATHROOM
K103
B2
26.002
26.002
TO SWITCH
BELOW
DOWN
KEYPLAN / PIANO STRATEGICO
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A T E
D E
S C
R
IP
T
IO
N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :3
A M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P O H E h o u s in g .r v t
GDA BWYSHA
O H
B U
IL
D
IN
G
F
IR
S
T F
L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E
O H
B U
IL
D
IN
G
P
IA
N
O P
R
IM
O
EL431
14127102
G D A
26.001. PROVIDE SWITCH FOR LIGHT FIXTURE ABOVE ACCESS
PANEL. / FORNIRE IN OPERA L'INTERRUTTORE PER
APPARECCHIO ILLUMINANTE AL DI SOPRA DEL PANNELLO DI
ACCESSO.
26.002. SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN.
REFER TO POWER AND MECHANICAL PLANS FOR LOCATION. /
INTERRUTTORE CON TEMPORIZZATORE PER ACCENSIONE
SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE
PIANTE ENERGIA ED IMPIANTI MECCANICI PER LA SUA
POSIZIONE.
SHEET KEYNOTES: / NOTE CHIAVE
DEL DISEGNO
SCALE: 1 : 50
A1
OH BUILDING 20160 FIRST FLOOR LIGHTING PLAN / PIANTA ILLUMINAZIONE OH BUILDING 20160 PIANO PRIMO
A CB
GARAGE
a
G5
ATTIC
a a a a a aa
G5
G5
G5 G5
G5
W1
W1 W1
MDP- 11
MDP- 18
LANDSCAPE LIGHTING
SEE SHEET ES402
LANDSCAPE LIGHTING
SEE SHEET ES402
G5
E L4
E
L4
TO W1
FIXTURE
TO B5
FIXTURE IN
CORRIDOR
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :3
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A A
G R
O U
N D
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A R
E A
A P
IA
N
O T
E R
R A
EL442
14127103
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20060 GROUND FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE TERRA
C D F G H J K
KITCHEN
BEDROOM
CLOSET
BATH
CLOSET
POWDER ROOM
MECH
ENTRY
MUD ROOM
GARAGE
VERANDA
DINING
LIVING
PANTRY
ADMIN
B8
B8
B9
B9
B9
B5
B5
B5 B5
B11
B5
B5
B5
B5
B5
B5
B5 B5
B5
B5
B5
B7
G4
G1
MOUNT AT
750 MM AFF
B5
CF
b b b c c c d d z y y f f f f g g g g g g g g g k k aa j(2) j
UC3 BELOW
EACH SHELF
aa h f m m m m l z g l j x x e e c p p p p n o no n o o o o o o o q q q q q q q q q CFs q s w v u t u v t u u u u u u u u v w u v cc
B5
B5
B5
B5
G4 o
B8 B8
B8
B8 B8 B8 h i gh
B5
B5
B5
B5
B5
B5 B5 B5
B3 B5
B5
B5B5
B5 B5
B5
B5
B5
B5
B9
B9
B9
B9
B9
B5
B5
B5 i i
B5 B5 u u
B5
B5 i p p p p
Q2
Q2 Q2 Q2 o o
B8 B8 q gg gggggggggggg gg gg gg gg gg gg
B9 g B5
B5 g
B5 g g
B5 o o
B8 B8 q
B9
B9 q q q q s q
B9
B10
B10
B9 s
B9
B9 s B10
B10 s
B12 B12
CF1
B7
B7
B7 B7
B7
B7 B7 B7 B7 B7
L2
L1
P3
P3
P2
P6
P1
P6
P5
P6
P6 P6
W1
W1 W1 W1 W1
W1 W1
W1
W1
W2
W2
B12
U1
U2
U1
U3
U4
CIRCUIT
MDP-11
CIRCUIT
MDP-18
LANDSCAPE LIGHTING
SEE SHEET ES402
LANDSCAPE LIGHTING
SEE SHEET ES402
LANDSCAPE LIGHTING
SEE SHEET ES402
E L4
E
L4 g g
B5
B5
26.507
26.507
26.507
E
W1 W1
TO Q2 ON EL445 /
A Q2 SU EL445
CF
PH 26.515
t t t y y y y y zz zz zz zzzz zz xxxx yy yy yy yy yy xx xx xx
W1 j
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :3
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A B
G R
O U
N D
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A R
E A
B P
IA
N
O T
E R
R A
EL443
14127104
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20060 GROUND FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE TERRA
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE
CON TEMPORIZZATORE PER ACCENSIONE /
SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE PIANTE
ENERGIA ED IMPIANTI MECCANICI PER LA SUA POSIZIONE.
26.515 LINE VOLTAGE INDOOR PHOTOCELL SENSOR FOR ON/OFF CONTROL OF Q2
STEP LIGHTS. CONTROL MUST BE ON AT DUSK, OFF AT DAWN - BASED ON
OUTDOOR LIGHT LEVEL. PHOTOCELL MUST BE WIRED IN SERIES WITH
LIGHT SWITCH FOR MANUAL OVERRIDE. LOCATE PHOTOCELL FLUSH
MOUNTED WITHIN THE WINDOW HEAD. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. / SENSORE A FOTOCELLULA DA INTERNO DELLA
TENSIONE DI LINEA PER IL CONTROLLO ON/OFF DI LUCI PASSO Q2. IL
COMANDO DEVE ESSERE ACCESO AL TRAMONTO, SPENTO ALL'ALBA - IN
BASE AL LIVELLO DI LUCE ESTERNA. LA FOTOCELLULA DEVE ESSERE
CABLATA IN SERIE CON INTERRUTTORE LUCE PER L'AZIONAMENTO
MANUALE. INDIVIDUARE LA FOTOCELLULA MONTATA A INCASSO
ALL'INTERNO DELLA TESTA DELLA FINESTRA. INSTALLARE SECONDO LE
RACCOMANDAZIONI DEL PRODUTTORE.
A C DB
B
G5 G5
G5
CIRCUIT MDP-11
E L4
E
L4
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :3
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A A
F
IR
S T
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A
R E
A A
P
IA
N O
P R
IM
O
EL444
14127105
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20060 FIRST FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE PRIMO
D F G H J K
BEDROOM 2
BEDROOM 1
BATH
LAUNDRY
FAMILY ROOM
CLOSET
MASTER BR
MASTER BATH
CLOSET/SAFE ROOM
B11
B7 B11 B7
B7 B7
B7
B7
B7 B7
B7
MOUNT AT 750 MM
AFF
MOUNT AT 750 MM
AFF
MOUNT AT 750
MM AFF
EM
EM
CF
CF
CF
cc cc cc cc ccdd dd dd dd dd dd ee ee ee eeee eeee eeee eeee ee ff ff ff ff ff ff
B7
B7
B7
B7
B7 B7
B7 B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7 bb bb B7
B7
B7 cc
B7 B7
B7
B7 B7
B7
CF
CF
L3
L3
P8
P4
E L4
E
L4
B7 B7B7
26.507 26.50726.507
E
Q2 Q2 Q2 Q2 Q2
FROM Q2 ON EL443 /
DA Q2 SU EL443
CF
CF
CF
CF
CF
B7 yyyyy
B7 zz zz zz zz zz zz zzzz zz zz zz zz zz zz
MDP- 35
zz zz zzzz zz zz hh hh hh gg gg ii ii ii jj jj jj jj kk kk ll ll ll mm mmnn nn
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP661 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP661
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES402. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :3
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A B
F
IR
S T
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A
R E
A B
P
IA
N O
P R
IM
O
EL445
14127106
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20060 FIRST FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20060 PIANO PARZIALE PRIMO
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE
CON TEMPORIZZATORE PER ACCENSIONE /
CB
G5
G5
GARAGE
MUD ROOM
ENTRY
b a
ATTIC
a a a a a a a
G5
G5
G5 G5 G5
W1 W1
W1
MDP- 11
MDP- 18
LANDSCAPE LIGHTING
SEE SHEET ES401
E L4
E
L4
A
TO W1
FIXTURE
TO B5
FIXTURE IN
CORRIDOR
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :0
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A A
G R
O U
N D
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A R
E A
A P
IA
N
O T
E R
R A
EL446
14127107
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20070 GROUND FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA
KJHGFEDC
B9
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5B5
G4
B5
B5
G1
MUD ROOM
ENTRY
MECH
STORAGE
PANTRY
KITCHEN
VERANDA
DINING
LIVING
FOYER
BATH
BEDROOM
CLOSET
POWDER ROOM
CLOSET
B5
MOUNT AT
750 MM AFF
b b f f f f h g g g g g gg g g h g jj k k m c c c c d d l l b e e no n o o o o o o oo p p p q s q q s t u v t v u v w w u u u u u v gh cc
B5
B7
B5
B5
B5 B5
B5
B5
B5 i
B5
B9
B9
B9
B9 B9
B9 B9
B9
B9
B10
B5
B5
B5
B5
B5B5 u
B5
B5
CF
B5
B11
B5 B5
B5
G4
B12 i i u u u uB5 B5
B5 B5 i m
B12 B12 p p B9
B9 o o cc cc cc cccc cc cc cccc cc
Q2
Q2 Q2 Q2 dd dd g
B5 g g g
B5
B5 B5 B5 q s q q B9
B9 q
B9
B10 s
B10 s
B10 s
B9 s
B9 s
B7
B7
B7
B7
B7
B7
B7
B7
L2
L1
CF1
P3
P3
P2
P6
P6
P6
P5
W1
W1
W1W1
W1
W1
W2
W2
U1
U1
U1
U2g
W1 W1
CIRCUIT
MDP-11
CIRCUIT MDP-18
LANDSCAPE LIGHTING
SEE SHEET ES401
LANDSCAPE LIGHTING
SEE SHEET ES401
E L4
E
L4 g
B5
B5 m m
B5
26.507
26.507
26.507
TO Q2 ON EL449 /
A Q2 SU EL449
W1 W1
PH 26.515
CF
CF
P1 no y y y y y zz zz zz zz zz zzxx xxyy yy yy yy yy xx xx xx
W1
W1 j pp pp pp pp
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :0
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A B
G R
O U
N D
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A R
E A
B P
IA
N
O T
E R
R A
EL447
14127108
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20070 GROUND FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE
CON TEMPORIZZATORE PER ACCENSIONE /
SPEGNIMENTO DELL'ASPIRATORE. FARE RIFERIMENTO ALLE PIANTE
ENERGIA ED IMPIANTI MECCANICI PER LA SUA POSIZIONE.
26.515 LINE VOLTAGE INDOOR PHOTOCELL SENSOR FOR ON/OFF CONTROL OF Q2
STEP LIGHTS. CONTROL MUST BE ON AT DUSK, OFF AT DAWN - BASED ON
OUTDOOR LIGHT LEVEL. PHOTOCELL MUST BE WIRED IN SERIES WITH
LIGHT SWITCH FOR MANUAL OVERRIDE. LOCATE PHOTOCELL FLUSH
MOUNTED WITHIN THE WINDOW HEAD. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. / SENSORE A FOTOCELLULA DA INTERNO DELLA
TENSIONE DI LINEA PER IL CONTROLLO ON/OFF DI LUCI PASSO Q2. IL
COMANDO DEVE ESSERE ACCESO AL TRAMONTO, SPENTO ALL'ALBA - IN
BASE AL LIVELLO DI LUCE ESTERNA. LA FOTOCELLULA DEVE ESSERE
CABLATA IN SERIE CON INTERRUTTORE LUCE PER L'AZIONAMENTO
MANUALE. INDIVIDUARE LA FOTOCELLULA MONTATA A INCASSO
ALL'INTERNO DELLA TESTA DELLA FINESTRA. INSTALLARE SECONDO LE
RACCOMANDAZIONI DEL PRODUTTORE.
DCB
G5 G5 G5
CIRCUIT MDP-11
E L4
E
L4
A
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :0
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A A
F
IR
S T
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A
R E
A A
P
IA
N O
P R
IM
O
EL448
14127109
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20070 FIRST FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA
KJHGFEDC
E L4
E
L4
BEDROOM 2
BEDROOM 1
BATH
LAUNDRY
FAMILY ROOM
CLOSET
MASTER BR
MASTER BATH
CLOSET/SAFE ROOM
B11
B7 B11 B7
B7 B7
B7
B7
B7
B7
B7
MOUNT AT 750 MM
AFF
MOUNT AT 750 MM
AFF
MOUNT AT 750 MM
AFF
EM
EM
CF
CF
CF
cc cc cc cc ccdd dd dd dd dd dd ee ee ee eeee ee ee eeee ee ee ee ff ff ff ff ff ff
B7
B7
B7
B7
B7
B7
B7 B7
B7 B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7 B7
B7
B7
B7 bb bb B7
B7
B7 cc
B7 B7 B7
B7
B7
B7
CF
CF
L3
L3
P8
P4B7 B7B7
26.507 26.50726.507
Q2 Q2 Q2 Q2 Q2
FROM Q2 ON EL447 /
DA Q2 SU EL447
CF
CF
CF
CF
CF
y y y y y
B7
B7 zz zz zz zz zz zz zz zz zz zz zz zz zz zz
MDP- 38
zz zz zz zzzz zz ii ii ii hh hh hh gg gg jj jj jj jj kk kk ll ll ll mm mm nn nn
CLOSET
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL
EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON
L'ATTREZZATURA MECCANICA INSTALLATA.
4. SEE INTERIOR LIGHTING FIXTURE SCHEDULES ON SHEETS EL601 AND EL602.
SEE INTERIOR LIGHTING FIXTURE DETAILS ON SHEETS EL501 THROUGH EL508
FOR SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE GLI APPARECCHI
DI ILLUMINAZIONE INTERNA SULLE SCHEDE EL601 E EL602. VEDERE I DETTAGLI
DELL'APPARECCHIO DI ILLUMINAZIONE INTERNA SULLE SCHEDE DA EL501 A
EL508 PER LE SPECIFICHE/REQUISITI DEGLI APPARECCHI.
5. SEE PANELBOARD SCHEDULE ON SHEET EP660 FOR CIRCUIT
DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP660
PER IL CIRCUITO DI RIFERIMENTO.
6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS
OTHERWISE NOTED, ROUTE CIRCUITRY CONCEALED IN ACCORDANCE WITH CEI
NORMS. / I LAYOUT DEI CIRCUITI ELETTRICI SONO SCHEMATICI. SALVO CHE
ALTRIMENTI, CIRCUITO DI PERCORSO NASCOSTO CONFORME ALLA NORMATIVA
CEI.
7. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I
CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.
8. FOR GFOQ LANDSCAPE LIGHTING (POWERED FROM THIS BUILDING), PLEASE
REFER TO SITE PLAN SHEET ES401. / PER L'ILLUMINAZIONE DEL PAESAGGIO
GFOQ (ALIMENTATA DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLA SCHEDA
DELLA PIANTA DEL SITO ES401.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
PLAN
NORTH
0 421 3 5
SCALE: 1:50
D A T E
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
KMC
7 DEC 2022
:4 :0
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P G F O Q E h o u s in g .r v t
DKB AJZLAK
G F
O Q
B U
IL
D
IN
G
A
R E
A B
F
IR
S T
F L O
O R
L
IG
H T
IN
G
P L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E G
F O
Q E
D
A
R E
A B
P
IA
N O
P R
IM
O
EL449
14127110
D K B
SCALE 1 : 50
A1
GFOQ BUILDING 20070 FIRST FLOOR PARTIAL LIGHTING PLAN /
PIANTA ILLUMINAZIONE GFOQ EDIFICIO 20070 PIANO PARZIALE TERRA
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.507 SWITCH WITH TIMER FOR TURNING ON/OFF EXHAUST FAN. REFER TO
POWER AND MECHANICAL PLANS FOR LOCATION OF THIS. / INTERRUTTORE
CON TEMPORIZZATORE PER ACCENSIONE /
CHAIN HUNG LIGHT
FIXTURE, 3000MM, AFF
(TYP) /
APPARECCHIO
ILLUMINANTE SOSPESO A
CATENA,3000MM, AFF
(TIPICO)
K
EM1
EM1
J
K
K
K
K
SP-10
W1
26.052
KEYPLAN / PIANO STRATEGICO
TORINO
PISA
BUILDING LOCATION / POSIZIONE DEL EDIFICIO
SIMILAR BUILDINGS / EDIFICI SIMILI
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A T E
D E
S C
R
IP
T
IO
N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :0
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P V S E s u b s ta ti o n .r v t
TRC CLWTRC
S U
B S
T A
T
IO
N L
IG
H
T
IN
G P
L A
N
P
IA
N T
A I L L U
M
IN
A Z
IO
N
E S
O T
T O
S T
A Z
IO
N
E
EL491
14127111
T R C
SCALE: 1 : 50
C1
SUBSTATION LIGHTING PLAN / PIANTA
ILLUMINAZIONE SOTTOSTAZIONE
GENERAL NOTES THIS SHEET:/
NOTE GENERALI DI QUESTO FOGLIO:
A. SEE ARCHITECTURAL, ELECTRICAL SITE AND CIVIL PLANS FOR
LOCATIONS AND NAMES OF BUILDINGS. / VEDERE LE PLANIMETRIE
ARCHITETTONICHE, ELETTRICHE E CIVILI PER LE POSIZIONI E I NOMI
DEGLI EDIFICI.
SHEET KEYNOTES: / NOTE CHIAVE
DI QUESTO FOGLIO
26.052 SEE SITE PLAN FOR EXACT LOCATION OF TYPE W1 FIXTURE ON
SUBSTATION BUILDING. / PER LA POSIZIONE ESATTA DELL'APPARECCHIO DI
TIPO W1 SULL'EDIFICIO DELLA SOTTOSTAZIONE, VEDERE LA PLANIMETRIA.
W/T
DT DT
WP
W/T
WP
W /T
W/T
W/T
W/T
W/T
W /T
WP
C1
EL394
B2
EL394
K H: 2.0 m
G1 H: 2.2 m
K H: 2.0 m
K H: 2.0 m
J005
STORAGE ROOM 1
J006
STORAGE ROOM 2
J001
RESTROOM
J002
UTILITY
J003
ELECTRICAL
EP-01
EP-01
EP-01
EP-01
EP-01
EP-01
EP-01
EP-01
26.264
A1
EL394 W4
H: 2.5 m W4
H: 2.5 m
K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1
K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1 K1
26.249
EP26.271
K H: 2.0 m
K H: 2.0 m
H1 H: 2.25 m
H1 H: 2.25 m
H1 H: 2.25 m
H1 H: 2.25 m
26.263
EP-01
K H: 2.0 m
B1 H: 2.04 m
J004
RESTROOM
B1 H: 2.04 m
G1 H: 2.0 m
PAVILION /
PADIGLIONE
BUILDING LOCATION / POSIZIONE DEL EDIFICIO
KEYPLAN / PIANO STRATEGICO
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
2 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A
TH
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.