Attachment AF_Amend0006_DWG_ELEC.pdf
PDF 1 MB Posted
- Solicitation number
- N6247023R0004
View the file
Other files
Show 40 more
Latest 50 of 85 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T V
T V
WP
R R
C R
A
C
C R
R
T
CR
T V
R R
R
D C
DT
WP
A C
T
T
CR
C R
T
T
R T
T
WPWP
A C
R T
R
T
S
SB
CO
CO
S
SB
GENERAL NOTES THIS SHEET: /
NOTE GENERALI DI QUESTO FOGLIO
A. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
VEDERE PIANTE ARCHITETTONICO E CIVILE PER UBICAZIONE DEGLI
EDIFICI.
B. SEE PANELBOARD SCHEDULES (SHEET EP652) FOR CIRCUIT
DESIGNATIONS INDICATED ON THIS SHEET. / VEDERE L'ABACO DEI
QUADRI DI DISTRIBUZIONE NELLE ABITAZIONI (TAVOLA EP652) PER LE
DESIGNAZIONI DI TUTTI I CIRCUITI INDICATI IN QUESTO FOGLIO.
C. SEE MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION AND ELECTRICAL LOADS OF MECHANICAL AND PLUMBING
EQUIPMENT. / VEDERE DISEGNI MECCANICI ED IDRAULICI PER
INFORMAZIONI AGGIUNTIVE E CARICHI ELETTRICI DEGLI APPARATI
MECCANICI E IDRAULICI
D. REFER TO MECHANICAL SHEETS FOR DISCONNECT INFORMATION. /
FARE RIFERIMENTO ALLE TAVOLE MECCANICHE PER INFORMAZIONI SUL
SEZIONATORE
E. SEE SHEETS E-001, E-002 AND E-003 FOR ABBREVIATIONS, LEGENDS AND
NOTES. / VEDERE TAVOLE E-001, E-002 E E-003 PER ABBREVIAZIONI,
LEGENDE E NOTE
F. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. PROVIDE
CIRCUITRY ROUTING CONCEALED IN ACCORDANCE WITH CEI NORMS. /
GLI SCHEMI DEI CABLAGGI DEI CIRCUITI ELETTRICI SONO SCHEMATICI.
FORNIRE IN OPERA IL PERCORSO DELLA CIRCUITERIA NASCOSTA
IN CONFORMITA' CON LE NORME CEI.
G. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCELED IN
RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS. / SE NON
ALTRIMENTI INDICATO, POSARE LA CIRCUITERIA INCASSATA NELLE
UNITA' RESIDENZIALI, AREE NUCLEO/SCALA DEGLI APPARTAMENTI
H. ALL CONDUIT RIGID OR FLEXIBLE WILL BE (1) ⌀20MM MINIMUM. / TUTTI I
TUBI PORTACAVO RIGIDI O FLESSIBILI DOVRANNO ESSERE (1) MINIMO
20MM DI DIAMETRO
I. ALL THE DISCONNECT SWITCH WILL BE A MINIMUM PROTECTION IP55. /
TUTTI GLI INTERRUTTORI SEZIONATORI DOVRANNO AVERE UNA
PROTEZIONE MINIMA IP55
EP
EP-7
EP-2
26.001
26.002
STORAGE
K007
STORAGE
K012
KITCHEN
K009
DINING
K010
LIVING
K011
HALF BATH
K003
FAMILY
K002
ENTRY
K001
MECHANICAL
K004
FOYER
K013
DWH-1
B-2
FCU-7
EP-09
GB
W
EP-14
26.004
EP-6
R
K
26.005
26.003
JEP-17
GARAGE
K005
P-2
U
U P-8
2P 16A
FPM
BP-1
E
EP-5 U
EP-1
EP-16
DC
EP-15
HP-7 2P 40A
FPM
26.006
26.007
26.008
26.009
EP-19
2P 16A
FPM
2P 16A
FPM2P 16A
FPM
2P 16A
FPM
2P 16A
FPM
EP-13
EF-5
EP-19
EP-19
2 2
KEYPLAN / PIANO STRATEGICO
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A T E
D E
S C
R
IP
T
IO
N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
C
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :5
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P O H E h o u s in g .r v t
GDA BWYSHA
O H
B U
IL
D
IN
G
G
R O
U N
D F
L O
O R
P O
W E
R P
L A
N
P
IA
N T
A A
L
IM
E N
T A
Z
IO
N E
O H
B U
IL
D
IN
G
P
IA
N
O T
E R
R A
EP430
14127153
G D A
SHEET KEYNOTES: / NOTE
CHIAVE DEL DISEGNO
26.001. MOUNT ABOVE COUNTER / INSTALLARE AL DI SOPRA DEL RIPIANO
26.002. TELECOM DEMARC LOCATION. REFER TO SHEET TS504 DETAIL C1.
PROVIDE ONE DUPLEX SOCKET INSIDE CABINET ON DEDICATED
CIRCUIT AND ONE DUPLEX SOCKET OUTSIDE CABINET FROM
CIRCUIT EP-15. / PUNTO DI CONFINE DELLE TELECOMUNICAZIONI.
VEDERE TAVOLA TS504 DETTAGLIO C1. FORNIRE IN OPERA UNA PRESA
DOPPIA ALL'INTERNO DELL'ARMADIO SU CIRCUITO DEDICATO E UNA
DOPPIA ALL'ESTERNO DEL CABINET DAL CIRCUITO EP-15.
26.003. PROVIDE ONE DUPLEX RECEPTACLE INSIDE MEDIA CABINET AND ONE
DUPLEX RECEPTACLE OUTSIDE CABINET ON DEDICATED CIRCUIT EP-16. /
FORNIRE UNA PRESA DOPPIA ALL'INTERNO DELL'ARMADIO MEDIA E UNA
DOPPIA ALL'ESTERNO DELL'ARMADIO SU CIRCUITO DEDICATO EP-16
26.004. PROVIDE IP43 RATING ENCLOSURE FOR PV SYSTEM INVERTER AND
RELATED CONTROLS EQUIPMENT. / FORNIRE CUSTODIA DI CLASSE IP43
PER INVERTER PER IMPIANTI FV E RELATIVE APPARECCHIATURE DI
CONTROLLO.
26.005. INSTALL SOCKET IN-CEILING FOR GARAGE DOOR OPENER / INSTALLARE
PRESA IN SOFFITTO PER APRIRE PORTA GARAGE
26.006. DATA OUTLET WITH WEATHERPROOF COVER USED FOR GAS METER. /
PRESA DATI INSIEME A COPERTURA IMPERMEABILIZZATA UTILIZZATA
PER CONTATORE DEL GAS.
26.007. DATA OUTLET WITH WEATHERPROOF COVER USED FOR WATER METER.
/ PRESA DATI INSIEME A COPERTURA IMPERMEABILIZZATA UTILIZZATA
PER CONTATORE DELL ACQUA.
26.008. DATA OUTLET WITH WEATHERPROOF COVER USED FOR ELECTRIC
METER. PRESA DATI INSIEME A COPERTURA IMPERMEABILIZZATA
UTILIZZATA PER CONTATORE DEL ELECTTRICO.
26.009. EXHAUST FAN FOR BATHROOM, SWITCHED ON/OFF BY SWITCH WITH
TIMER. REFER TO LIGHTING PLANS FOR LOCATION. / ASPIRATORE PER
IL BAGNO, COMANDATO ON/OFF DA INTERRUTTORE TEMPORIZZATO.
FARE RIFERIMENTO ALLE PIANTE ILLUMINAZIONE PER LA SUA
POSIZIONE.
SCALE: 1 : 50
A1
OH BUILDING 20160 GROUND FLOOR POWER PLAN / PIANTA ALIMENTAZIONE OH BUILDING 20160 PIANO TERRA
A
M E
N D
-F
IN
A L
C O
M M
E N
T S
/0
3/
W
H H
A
M E
N D
-P A
V E
M E
N T
M A
R K
IN
G
S
/2 6/
W H
H jerold.craghead Image
M A
R K
D A T E
D E
S C
R
IP
T
IO
N
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE:
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O R
FO
LK
VA
VI
LL
AG
G
IO
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
T L A
N T
IC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O T T E D
H
AM
P
TO
N
B
LV
D
VI
C E N Z A, IT
AL
Y
P -9
A R
M Y
F A
M
IL
Y H
O U
S
IN
G P
R O
JE
C
1669111
N62470-20-D-0008
CCA/MPO
R. STEPHENS, PE
DPS
AS NOTED
F
IL
E
P A T H
U S E R
SEK
7 DECEMBER 2022
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email.
:0 :5
P M
B
IM
B P A M E R
V ic e n z a p h a s e
IV
A F H P O H E h o u s in g .r v t
GDA BWYSHA
O H
B U
IL
D
IN
G
E
L E
C T
R
IC
A L P
A N
E L B
O A
R D
S C
H E
D U
L E
E
L E
N C
H I
Q U
A D
R O
E L E
T T
R
IC
O T
E R
M
IN
A L E
O H
B U
IL
D
IN
G
EP652
14127187
G D A
A
M E
N D
-P A
V E
M E
N T
M A
R K
IN
G
S
5/
/2
W
H H jerold.craghead Image
| Sheets |
| EP430 - OH BUILDING 20160 GROUND FLOOR POWER PLAN / PIANTA ALIMENTAZIONE OH BUILDING 20160 PIANO TERRA |
| EP652 - OH BUILDING 20160 ELECTRICAL PANELBOARD SCHEDULE / ELENCHI QUADRO ELETTRICO TERMINALE OH BUILDING 20160 |
File details come from the government source that posted it. Updated .