240016 Drawings Landscaping.pdf
PDF 6 MB Posted
- Attached to
- Repair BEQ BB250
- Solicitation number
- N408525R9008
About this file
The documents are landscape architectural drawings (L-701 and L-702) for the Repair BEQ BB250 project at Marine Corps Base Camp Lejeune. The drawings provide detailed landscape design specifications, including planting and landscape bed configurations with technical cross-sections and plan views. Key details include grass planting instructions with specifications for soil preparation, plant positioning, and landscape bed construction, with specific notes about existing site conditions and installation requirements. The drawings are part of a comprehensive set of contract documents for a repair and renovation project, prepared by MBF Architects and dated February 18, 2025, with a project number of 24-0016 and associated with Naval Facilities Engineering Systems Command.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIST OF DRAWINGS
Contract drawings are as follows:
NAVFAC SHEET
NO. NO. TITLE
G GENERAL
60041505 G-001 TITLE SHEET AND INDEX OF DRAWINGS
GI LIFE SAFETY
60041506 GI001 LIFE SAFETY GENERAL NOTES AND LEGEND
60041507 GI002 CODE COMPLIANCE SITE PLAN
60041508 GI101 LIFE SAFETY FIRST FLOOR PLAN - CONSTRUCTION
60041509 GI102 LIFE SAFETY SECOND AND THIRD FLOOR PLAN - CONSTRUCTION
C CIVIL
60041510 C-001 CIVIL NOTES, LEGEND AND ABBREVIATIONS
60041511 CD101 SITE PLAN-EXISTING CONDITIONS AND DEMOLITION
60041512 CS101 SITE PLAN-NEW WORK
60041513 CG101 SITE GRADING PLAN
60041514 CU101 SITE UTILITY PLAN
60041515 CU102 ENLARGED SITE UTILITY PLAN
60041516 CS501 DETAILS
60041517 CS502 DETAILS
60041518 CG501 DETAILS
60041519 CG502 DETAILS
60041520 CU501 DETAILS
60041521 CU502 DETAILS
L LANDSCAPE
60041521A L-701 SITE LANDSCAPE PLAN
60041521B L-702 DETAILS
S STRUCTURAL
60041522 S-101 GENERAL NOTES
60041523 S-102 CONCRETE REPAIR PLAN
60041524 S-103 MECHANICAL EQUIPMENT BUILDING - CONSTRUCTION
60041525 S-201 MECHANICAL EQUIPMENT BUILDING SECTIONS
60041526 S-501 TYPICAL CONSTRUCTION DETAILS
A ARCHITECTURAL
60041527 A-001 SYMBOL LEGEND AND ABBREVIATIONS
60041528 AD101 FIRST AND SECOND FLOOR PLANS - EXISTING/DEMOLITION
60041529 AD102 THIRD FLOOR AND ROOF PLANS - EXISTING/DEMOLITION
60041530 AD103 REFLECTED CEILING PLANS - EXISTING/DEMOLITION
60041531 AD104 REFLECTED CEILING PLANS - EXISTING/DEMOLITION
60041532 AD110 BUILDING BB251 - EXISTING/DEMOLITION
60041533 AD201 EXTERIOR ELEVATIONS - EXISTING/DEMOLITION
60041534 AD401 ENLARGED PLANS - EXISTING/DEMOLITION
60041535 AD402 ENLARGED PLANS - EXISTING/DEMOLITION
60041536 AD403 ENLARGED PLANS - EXISTING/DEMOLITION
60041537 A-101 FIRST AND SECOND FLOOR PLANS - CONSTRUCTION
60041538 A-102 THIRD FLOOR PLAN - CONSTRUCTION
60041539 A-103 ROOF PLAN - CONSTRUCTION
60041540 A-104 REFLECTED CEILING PLANS - CONSTRUCTION
60041541 A-105 REFLECTED CEILING PLANS - CONSTRUCTION
60041542 A-110 MECHANICAL EQUIPMENT BUILDING - CONSTRUCTION
NAVFAC SHEET
NO. NO. TITLE
60041543 A-111 MECHANICAL EQUIPMENT BUILDING - CONSTRUCTION
60041544 A-201 EXTERIOR ELEVATIONS - CONSTRUCTION
60041545 A-301 BUILDING SECTIONS
60041546 A-310 WALL SECTIONS
60041547 A-401 ENLARGED PLANS - CONSTRUCTION
60041548 A-402 ENLARGED PLANS - CONSTRUCTION
60041549 A-403 ENLARGED PLANS - CONSTRUCTION
60041550 A-404 ENLARGED REFLECTED CEILING PLANS - CONSTRUCTION
60041551 A-405 ENLARGED REFLECTED CEILING PLANS - CONSTRUCTION
60041552 A-406 ENLARGED SLEEPING ROOM BATH, INTERIOR ELEVATIONS,
AND DETAILS
60041553 A-407 ENLARGED TOILET PLANS, INTERIOR ELEVATIONS, AND DETAILS
60041554 A-501 ASSEMBLES
60041555 A-502 DETAILS
60041556 A-503 DETAILS
60041557 A-504 GUARDRAIL DETAILS
60041558 A-601 DOOR AND FRAME SCHEDULE AND DETAILS
60041559 A-602 DOOR AND FRAME DETAILS
60041560 A-603 DOOR AND FRAME DETAILS, WINDOW SCHEDULE, AND DETAILS
I INTERIOR DESIGN
60041561 I-101 FIRST FLOOR FINISH PLAN
60041562 I-102 SECOND FLOOR FINISH PLAN
60041563 I-103 THIRD FLOOR FINISH PLAN
60041564 I-111 FIRST FLOOR SIGNAGE PLAN
60041565 I-112 SECOND FLOOR SIGNAGE PLAN
60041566 I-113 THIRD FLOOR SIGNAGE PLAN
60041567 I-201 INTERIOR ELEVATIONS
60041568 I-301 CASEWORK SECTIONS
60041569 I-401 ENLARGED FINISH PLANS
60041570 I-402 ENLARGED SIGNAGE PLAN
60041571 I-501 SIGNAGE DETAILS
60041572 I-502 INTERIOR DETAILS
60041573 I-601 SCHEDULES & LEGENDS
F FIRE PROTECTION
60041574 FA001 FIRE ALARM GENERAL NOTES AND LEGEND
60041575 FA101 FIRE ALARM FIRST FLOOR PLAN - CONSTRUCTION
60041576 FA102 FIRE ALARM SECOND FLOOR PLAN - CONSTRUCTION
60041577 FA103 FIRE ALARM THIRD FLOOR PLAN - CONSTRUCTION
60041578 FA501 FIRE ALARM DETAILS
60041579 FA502 FIRE ALARM DETAILS
60041580 FX001 FIRE SUPPRESSION GENERAL NOTES AND LEGEND
60041581 FX101 FIRE SUPPRESSION FIRST FLOOR PLAN - CONSTRUCTION
60041582 FX102 FIRE SUPPRESSION SECOND FLOOR PLAN - CONSTRUCTION
60041583 FX103 FIRE SUPPRESSION THIRD FLOOR PLAN - CONSTRUCTION
60041584 FX501 FIRE SUPPRESSIONI DETAILS
P PLUMBING
60041585 P-001 PLUMBING COVER SHEET
60041586 PD101 EXISTING / DEMOLITION FLOOR PLANS - PLUMBING
60041587 P-101 FLOOR PLANS - WASTE AND VENT
60041588 P-102 PARTIAL ENLARGED FLOOR PLANS - FIRST FLOOR -
WASTE AND VENT
60041589 P-103 PARTIAL ENLARGED FLOOR PLANS - SECOND FLOOR -
WASTE AND VENT
60041590 P-104 PARTIAL ENLARGED FLOOR PLANS - THIRD FLOOR -
WASTE AND VENT
60041591 P-105 FLOOR PLANS - WATER
60041592 P-106 PARTIAL ENLARGED FLOOR PLANS - FIRST FLOOR - WATER
60041593 P-107 PARTIAL ENLARGED FLOOR PLANS - SECOND FLOOR - WATER
60041594 P-108 PARTIAL ENLARGED FLOOR PLANS - THIRD FLOOR - WATER
60041595 P-501 PLUMBING DETAILS
60041596 P-601 PLUMBING SCHEDULES
60041597 P-701 RISER DIAGRAMS - WASTE AND VENT
60041598 P-702 RISER DIAGRAMS - WATER
M MECHANICAL
60041599 M-001 MECHANICAL NOTES, LEGEND, AND ABBREVIATIONS
60041600 MD101 OVERALL FIRST AND SECOND FLOOR PLANS - HVAC
60041601 MD102 OVERALL THIRD FLOOR AND ROOF PLANS - HVAC
60041602 MD103 OVERAL FIRST, SECOND & FLOOR PLANS - PIPING
60041603 MD104 TYPICAL SLEEPING ROOM ENLARGED FLOOR PLAN
60041604 MD105 FIRST FLOOR PLAN MECHANICAL ROOMS ENLARGED
60041605 MD106 FIRST FLOOR PLAN CENTRAL CORE ENLARGED
60041606 MD107 SECOND FLOOR PLAN MECHANICAL ROOMS ENLARGED
60041607 MD108 SECOND FLOOR PLAN CENTRAL CORE ENLARGED
60041608 MD109 THIRD FLOOR PLAN MECHANICAL ROOMS ENLARGED
60041609 MD110 THIRD FLOOR PLAN CENTRAL CORE ENLARGED
60041610 MD111 SITE PLAN MECHANICAL DEMOLITION
60041611 M-101 OVERALL FIRST AND SECOND FLOOR PLANS - HVAC
60041612 M-102 OVERALL THIRD FLOOR AND ATTIC PLANS - HVAC
60041613 M-103 OVERALL FIRST AND SECOND FLOOR PLANS - PIPING
60041614 M-104 OVERALL THIRD FLOOR AND ATTIC PLANS - PIPING
60041615 M-105 TYPICAL SLEEPING ROOM ENLARGED FLOOR PLAN
60041616 M-106 FIRST FLOOR PLAN MECHANICAL ROOMS ENLARGED
60041617 M-107 FIRST FLOOR PLAN CENTRAL CORE ENLARGED
60041618 M-108 SECOND FLOOR PLAN MECHANICAL ROOMS ENLARGED
60041619 M-109 SECOND FLOOR PLAN CENTRAL CORE ENLARGED
60041620 M-110 THIRD FLOOR PLAN MECHANICAL ROOMS ENLARGED
60041621 M-111 THIRD FLOOR PLAN CENTRAL CORE ENLARGED
60041622 M-112 SITE PLAN MECHANICAL NEW WORK
60041623 M-301 MECHANICAL SECTION VIEWS
60041624 M-302 MECHANICAL SECTION VIEWS
60041625 M-303 MECHANICAL SECTION VIEWS
60041626 M-304 MECHANICAL SECTION VIEWS
60041627 MD401 EXISTING MECHANICAL BUILDING - ENLARGED DEMOLITION
60041628 M-401 EXISTING MECHANICAL BUILDING - ENLARGED
60041629 M-501 MECHANICAL DETAILS
60041630 M-502 MECHANICAL DETAILS
60041631 M-503 MECHANICAL DETAILS
60041632 M-504 MECHANICAL DETAILS
60041633 M-505 MECHANICAL DETAILS
60041634 M-506 MECHANICAL DETAILS
60041635 M-507 MECHANICAL DETAILS
60041636 M-601 MECHANICAL SCHEDULES
60041637 M-602 MECHANICAL SCHEDULES
60041638 M-701 MECHANICAL CONTROLS
60041639 M-702 MECHANICAL CONTROLS
60041640 M-703 MECHANICAL CONTROLS
60041641 M-704 MECHANICAL CONTROLS
60041642 M-705 MECHANICAL CONTROLS
60041643 M-706 MECHANICAL CONTROLS
60041644 M-801 EXISTING DUAL TEMPERATURE WATER SYSTEM DIAGRAM
60041645 M-802 CHILLED WATER SYSTEM DIAGRAM
60041646 M-803 HOT WATER SYSTEM DIAGRAM
E ELECTRICAL
60041647 E-001 ELECTRICAL NOTES AND LEGENDS
60041648 ES101 SITE PLAN - ELECTRICAL
60041649 ES501 SITE ELECTRICAL DETAILS
60041650 ED101 OVERALL FLOOR PLANS - ELECTRICAL DEMOLITION
60041651 ED102 ATTIC PLAN - ELECTRICAL DEMOLITION
60041652 ED103 TYPICAL SLEEPING ROOM PLAN - ELECTRICAL DEMOLITION
60041653 ED104 FIRST FLOOR PLANS - ELECTRICAL DEMOLITION
60041654 ED105 SECOND FLOOR PLANS - ELECTRICAL DEMOLITION
60041655 ED106 THIRD FLOOR PLANS - ELECTRICAL DEMOLITION
60041656 E-101 OVERALL FLOOR PLANS - ELECTRICAL
60041657 E-102 ATTIC PLAN - ELECTRICAL
60041658 E-103 TYPICAL SLEEPING ROOM PLAN - ELECTRICAL
60041659 E-104 FIRST FLOOR PLANS - ELECTRICAL
60041660 E-105 FIRST FLOOR PLANS - ELECTRICAL
60041661 E-106 SECOND FLOOR PLANS - ELECTRICAL
60041662 E-107 SECOND FLOOR PLANS - ELECTRICAL
60041663 E-108 THIRD FLOOR PLANS - ELECTRICAL
60041664 E-109 THIRD FLOOR PLANS - ELECTRICAL
60041665 E-110 MECHANICAL BUILDING PLANS - ELECTRICAL
60041666 E-111 OVERAL FLOOR PLANS - CABLE TRAYS
60041667 E-501 ELECTRICAL DETAILS
60041668 E-502 ELECTRICAL DETAILS
60041669 E-503 ELECTRICAL DETAILS
60041670 E-504 ELECTRICAL DETAILS
60041671 E-601 ELECTRICAL SCHEDULES
60041672 E-602 ELECTRICAL SCHEDULES
60041673 E-603 ELECTRICAL SCHEDULES
60041674 E-604 ELECTRICAL SCHEDULES
60041675 E-605 ELECTRICAL SCHEDULES
60041676 E-606 ELECTRICAL SCHEDULES
60041677 E-607 ELECTRICAL SCHEDULES
60041678 E-701 ELECTRICAL RISER DIAGRAM
MCB Camp Lejeune and MCAS New River
F ile
P ri n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERET
SI
G E R
N
OI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
C U s e rs
\s c h m ie d
\D o c u m e n ts
\S c h m ie d
L o c a l F ile s \2
B
B
A
R C
H
S c h m ie d M
B F
A .r v t
/1
/2
:4
:3
A
M
G-001
JAS
DJE,III
KELLY ROOT
JAS
REPAIR BEQ BB250
TITLE SHEET AND INDEX OF DRAWINGS
60041505 N40085-24-B-0016
05-24-0016 1 OF 174
18 FEBRUARY 2025
REPAIR BEQ BB250
MARINE CORPS BASE CAMP LEJUENE
REGIONAL MAP
VICINITY MAP
SITE MAP
PROJECT LOCATION
BB250 SITE MAP GENERAL PROJECT NOTES GOVERNING REGULATIONS
BUILDING CODE:
UNIFIED FACILITIES CRITERIA (UFC) 1-200-01 (01 SEP 2022, W/ CHANGE 3, 26 FEB 2024) UNIFIED FACILITIES CRITERIA (UFC) 1-200-02 (01 DEC. 2020, W/CHANGE 02, 01 JUN 2022) UNIFIED FACILITIES CRITERIA (UFC) 3-110-03 (01 MAY 2012, W/CHANGE 5, 12 JUN 2020)
ACCESSIBILITY CODE:
UNIFORM ACCESSIBILITY STANDARDS (UFAS)
AMERICANS WITH DISABILITIES ACT (ADA)
ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (ADAAG)
MECHANICAL CODE:
INTERNATIONAL MECHANICAL CODE (IMC) 2021
ELECTRICAL CODE:
NFPA 70, NATIONAL ELECTRIC CODE (2023)
PLUMBING CODE:
INTERNATIONAL PLUMBING CODE (IPC) 2021
FIRE PREVENTION & LIFE SAFETY CODE:
UNIFIED FACILITIES CRITERIA (UFC) 3-600-01 (15 DEC. 2016, W/CHANGE 6, 06 MAY 2021)
NFPA 101, LIFE SAFETY CODE (2024)
1. WHERE EXISTING CONSTRUCTION IS DAMAGED BY CONSTRUCTION ACTIVITIES, PATCH
AND REPAIR DAMAGED ITEMS USING MATERIALS MATCHING EXISTING CONSTRUCTION.
REPAIRS ARE TO MATCH EXISTING MATERIAL, TEXTURE, AND COLOR TO PROVIDE
SEAMLESS TRANSITION IN APPEARANCE.
2. FIELD VERIFY EXISTING DIMENSIONS, PRIOR TO ORDERING MATERIALS OR BEGINNING
DEMOLITION.
3. ALL ITEMS NOT SHOWING AS "EXISTING" MUST BE PROVIDED AND INSTALLED UNDER THE
REQUIREMENTS OF THIS CONTRACT.
4. COORDINATE LAY DOWN AREA WITH THE CONTRACTING OFFICER PRIOR TO THE
PRECONSTRUCTION MEETING. THE ALLOWABLE AREA SIZE MUST BE ESTABLISHED BY
THE CONTRACTING OFFICER.
5. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY.
PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY MATCH
THE COLOR, FINISHES, TEXTURES AND PATTERNS OF THE MANUFACTURER LISTED, AND
MEET THE TECHNICAL REQUIREMENTS OF THE SPECIFICATIONS.
6. OBSERVE AND MAINTAIN BUILDING AND COMPOUND SECURITY REQUIREMENTS AS
DIRECTED BY THE CONTRACTING OFFICER.
7. CONSTRUCTION WILL BE ACCOMPLISHED IN AND AROUND AREAS WHICH WILL REMAIN
OPERATIONAL. AVOID INTERFERENCE WITH THE OPERATIONAL WORK ROUTINE.
8. ALL SUBMITTALS REQUIRED BY THESE DRAWINGS OR SPECIFICATIONS MUST BE
SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO COMMENCEMENT
OF RELATED WORK.
ARCHITECT
MBF ARCHITECTS, P.A.
317-C POLLOCK STREET
NEW BERN, NC 28560
CIVIL
AVOLIS ENGINEERING, P.A.
P.O. BOX 15564
NEW BERN NC 28561
LANDSCAPE
GEOTECHNICAL
LIFE SAFETY
JENSEN HUGHES
4445 CORPORATION LANE, SUITE 211
VIRGINIA BEACH, VA 23455
STRUCTURAL
KAYDOS-DANIELS ENGINEERS, PLLC
400-201 WEST MORGAN STREET
RALEIGH, NC 27603
COMPREHENSIVE INTERIOR DESIGN
WITHIN INTERIOR DESIGN, INC.
1008 GRANBY STREET
NORFOLK, VA 23510
FIRE ALARM /FIRE PROTECTION
JENSEN HUGHES
4445 CORPORATION LANE, SUITE 211
VIRGINIA BEACH, VA 23455
PLUMBING / MECHANICAL / ELECTRICAL
CRENSHAW CONSULTING ENGINEERS
3516 BUSH STREET, SUITE 200
RALEIGH, NC 27609
TELECOMMUNICATIONS
CRENSHAW CONSULTING ENGINEERS
3516 BUSH STREET, SUITE 200
RALEIGH, NC 27609
LIGHTNING PROTECTION
CRENSHAW CONSULTING ENGINEERS
3516 BUSH STREET, SUITE 200
RALEIGH, NC 27609
AUDIOVISUAL
DESIGN TEAM
N
N
N
N
BB250 SITE
PROJECT SITE
PROJECT NO.: 24-0016
1 AMDT 01 07/11/2025
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO. N40085-24-B-0016
SCALE SHEET
M
BF
A N
O
SPEC. 05-24-0016
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
MSP/JKA
JCA
J. FRANKLIN ORR, PE
JKA
JKA
L-701
SITE LANDSCAPE PLAN
TN
PN
REPAIR BEQ BB250
60041521A
PLANTING SCHEDULE
DESIGNATION COMMON NAME BOTANICAL NAME SIZE
S-1 Pink muhly grass Muhlenbergia capillaris 3 gallon
Digitally signed by John K Avolis
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO. N40085-24-B-0016
SCALE SHEET
M
BF
A N
O
SPEC. 05-24-0016
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
MSP/JKA
JCA
J. FRANKLIN ORR, PE
JKA
JKA
REPAIR BEQ BB250
60041521B
L-702
DETAILS
Digitally signed by John K Avolis
| Sheets |
| G-001 - TITLE SHEET AND INDEX OF DRAWINGS |
File details come from the government source that posted it. Updated .