Amen02 dwg 60039105r1.pdf
PDF 467 KB Posted
- Attached to
- Repair By Replacement TC601 Federal contract opportunity
- Solicitation number
- N4008523R2850
About this file
This document contains mechanical HVAC floor plans and details for a church renovation project. The plans show the proposed layout and locations for air handling units, power ventilators, electric unit heaters, chillers and associated ductwork and piping. Keyed notes provide installation instructions and coordination requirements.
The related federal contract opportunity is a solicitation from the Naval Facilities Engineering Command to provide repair by replacement services for a TC601 facility. Details include the solicitation number, project name, opportunity type as a solicitation, and issuing agency. No further information is provided on response dates, award dates, pricing terms, set asides or other contract requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amen07 Photos2of3.pdf | ||
| Amen 07 Photos3of3.pdf | ||
| Amen07 Photos1of3.pdf | ||
| Amen07 220049.pdf | ||
| Amen06 Dwg SKS-1.pdf | ||
| Amen06 220049.pdf | ||
| Amen05 220049.pdf | ||
| Amen04 220049.pdf | ||
| Amen04 dwg 60039100r2.pdf | ||
| Amen04 Spec 23 07 00r1.pdf | ||
| Amen04 dwg 60039111r1.pdf | ||
| Amen03 220049.pdf | ||
| Amen02 220049.pdf | ||
| Amen02 dwg 60039115r1.pdf | ||
| Amen02 220049.pdf | ||
| Amen02 dwg 60039100r1.pdf | ||
| 22-0049 PIS.pdf | ||
| Amen01 220049.pdf | ||
| 22-0049 APPD.pdf | ||
| 22-0049 Design Analysis.pdf | ||
| RFP 220049.pdf | ||
| 22-0049 Geotechnical Report.pdf | ||
| N4008522B0049 DRWGS.pdf | ||
| N4008522B0049 SPECS.pdf |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L04
PV03
L03
BT01
S
E
S6
S6
S5
S5
Ø
Ø
22Ø
Ø
22Ø
Ø
S6
S6
S6
S6
S6
S6
S6
S6
S6
S6
S6
S6
S6
S6
Ø
Ø
20Ø
Ø
20Ø
Ø
ADMIN.
OFFICE
WOMEN
CLOSET
NARTHEX
MEN
PRAYER
ROOM
JANITOR
NAVE
SOUTH
TRANSEPT
SANCTUARY
NORTH
TRANSEPT
BAND
PLATFORM
SACRISTY
CLOSET
EXIT
113 STORAGE
RISER
ROOM
MECH
FELLOWSHIP
STORAGE
RAMP
ENTRY
UNISEX
123 DRESSING
SOUND
BOOTH
I.T.
ROOM
107A
M
Ø
Ø
EUH01
AH01
CH01
R2
TH
AH01
40x24
043801
TROY O. GRADY
SEAL
R
EENI GN
P R
OF E S S I ON
A
E
L
NO
RT H CAROL I NA
SEE DISCLOSURE OF INFORMATION STATEMENT ON SHEET G-001
2246 Yaupon Drive Wilmington, NC 28401
Phone: 910.791.4000 Fax: 910.791.5266 www.cbhfengineers.com NC# P-0506c Copyright 2023CBHF Engineers, PLLC
Engineers, PLLC
06-08-2023
151 Poole Rd. Suite 100 | Leland, NC, 28451
TEL (910) 383-1044 | FAX (910) 383-1045
www.capefearengineering.com | N.C. LICENSE # C-1621
GENERAL NOTES
INSTALL NEW AIR HANDLING UNIT ON CONCRETE HOUSEKEEPING PAD, WHILE MAINTAINING ALL
OF THE MANUFACTURERS RECOMMENDED CLEARANCES.
INSTALL INTAKE LOUVER AT 10FT. ABOVE FINISHED GRADE MINIMUM.
INSTALL INTAKE LOUVER WITH MOTORIZED DAMPER INTERLOCKED TO PV03, AT 10 FT. ABOVE
FINISHED GRADE MINIMUM.
INSTALL POWER VENTILATOR ON ROOF IN LOCATION SHOWN WHILE MAINTAINING ALL OF THE
MANUFACTURERS RECOMMENDED CLEARANCES.
SUSPEND ELECTRIC UNIT HEATER IN LOCATION SHOWN WHILE MAINTAINING ALL OF THE
MANUFACTURERS RECOMMENDED CLEARANCES.
INSTALL CHILLER ON 10" CONCRETE HOUSEKEEPING PAD, WHILE MAINTAINING ALL OF THE
MANUFACTURERS RECOMMENDED CLEARANCES. SEE DETAIL 1/M-501 AND 3/M-502 FOR
FURTHER INFORMATION.
COORDINATE WITH E.C. WHEN LOCATING DIFFUSER TO LIMIT INTERFERENCE WITH PENDENT
LIGHTING.
COORDINATE LOCATION OF DUCTWORK WALL PENETRATION WITH TRUSS PROFILE.
KEYED NOTES
1. ALL EXPOSED DUCTWORK TO BE DOUBLE WALL SPIRAL AND MUST BE SUSPENDED USING
STAINLESS STEEL CABLES.
2. MODIFY/COORDINATE DUCT LAYOUT WITH TRUSS PROFILE AND SPACING.
MH101
MECHANICAL HVAC
FLOOR PLAN
MH401
MH401
MH401
7 (TYP.)
1/8" = 1'-0" 0 8' 16'4'1 FLOOR PLAN
PLAN
NORTH
1 REVISED PER RFI 02 08/08/2023
08/08/2023
| 2023-08-08T16:09:03-0400 | |
| Troy O Grady |
File details come from the government source that posted it. Updated .