SYMBOLS - COMMUNICATION ABBREVIATIONS (CONT.)
WIRE IN CONDUIT, ROUTE CONCEALED ABOVE CEILING OR IN WALL.
WIRE IN CONDUIT, ROUTE BELOW GRADE OR FLOOR SLAB.
COMMUNICATION DUCTBANK
ELECTRICAL DUCTBANK
UNDERGROUND TELECOM CONDUIT/CABLING
DEMOLITION UNDERGROUND TELECOM CONDUIT/CABLING
UNDERGROUND CATV CONDUIT/CABLING
DEMOLITION UNDERGROUND CATV CONDUIT/CABLING
UNDERGROUND FIBER CONDUIT/CABLING
CABLE TRAY. TYPE AND MOUNTING HEIGHT AS
INDICATED ON PLANS. NETWORK TYPE WITH '/' IS DIVIDED TRAY.
BT - BASKET TRAY
LT - LADDER TRAY
CR - CABLE RUNWAY
CABLE TRAY FITTING
WALL OR FLOOR BOX MOUNTED VOICE DATA OUTLET BOX. LETTER
INDICATES OUTLET TYPE. MOUNT WALL OUTLET 18" AFF UON. SEE
TN501 FOR DETAILS.
FURNITURE MOUNTED VOICE DATA OUTLET BOX. LETTER
INDICATES OUTLET TYPE. SEE TN501 FOR DETAILS.
CEILING MOUNTED WIRELESS ACCESS POINT (WAP).
WALL MOUNT FURNITURE FEED JUNCTION BOX,
18" AFF, UON.
FFN - FURNITURE FEED, NON-SECURE
COMBINATION FLOOR BOX
WALL MOUNTED TV OUTLET, REFER TO TA SERIES DRAWINGS FOR
MOUNTING HEIGHTS.
EQUIPMENT RACK. REFER TO SCHEDULES AND ELEVATIONS FOR
ADDITIONAL INFORMATION.
EQUIPMENT CABINET WITH DOOR SWING AND CLEARANCES
SHOWN. REFER TO SCHEDULES AND ELEVATIONS FOR
ADDITIONAL INFORMATION.
PUBLIC ADDRESS CENTRAL PROCESSING UNIT
PUBLIC ADDRESS OVERRIDE MODULE
PUBLIC ADDRESS TELEPHONE INTERFACE MODULE
PUBLIC ADDRESS ZONE CONTROLLER
PUBLIC ADDRESS MEDIA CONVERTER
PUBLIC ADDRESS CEILING MOUNTED SPEAKER
'CPA' = CRASH PUBLIC ACCESS
PUBLIC ADDRESS WALL MOUNTED SPEAKER
COMM
E
1. THIS PROJECT REQUIRES UNDERGROUND WORK INCLUDING A LARGE
PORTION OF THE WORK BEING PERFORMED IN EXISTING ROADWAYS
AND PAVEMENTS. THE CONTRACTOR SHALL REPAIR ALL EXISTING
ROADWAYS AND PAVEMENTS TO MATCH EXISTING.
2. THE UNDERGROUND WORK FOR THIS PROJECT REQUIRES CLOSE
COORDINATION WITH EXISTING UTILITIES. THE CONTRACTOR SHALL
VERIFY AND COORDINATE ALL WORK WITH ALL EXISTING UTILITIES,
EXISTING EQUIPMENT, AND EXISTING CONDITIONS.
3. PRIOR TO DIGGING, THE CONTRACTOR SHALL OBTAIN ALL APPLICABLE
DIGGING PERMITS. ALL UNDERGROUND UTILITIES IN THE WORK AREA
MUST BE POSITIVELY IDENTIFIED BY A PRIVATE UTILITY LOCATING
SERVICE IN ADDITION TO APPLICABLE BASE LOCATING SERVICE AND
COORDINATED WITH THE BASE UTILITY DEPARTMENT. ALL MARKINGS
MADE DURING THE UTILITY INVESTIGATION MUST BE MAINTAINED
THROUGHOUT THE CONTRACT.
4. THE CONTRACTOR SHALL PHYSICALLY VERIFY UNDERGROUND UTILITY
LOCATIONS BY HAND DIGGING AND/OR POT-HOLING USING WOOD OR
FIBERGLASS HANDLED TOOLS WHEN ANY ADJACENT CONSTRUCTION
WORK IS EXPECTED TO COME WITHIN THREE FEET OF THE
UNDERGROUND SYSTEM. DIGGING WITHIN 2 FEET OF A KNOWN UTILITY
SHALL NOT BE PERFORMED BY MEANS OF MECHANICAL EQUIPMENT;
HAND DIGGING SHALL BE USED. IF CONSTRUCTION IS PARALLEL TO AN
EXISTING UTILITY EXPOSE THE UTILITY BY HAND DIGGING EVERY 100
FEET IF PARALLEL WITHIN 5 FEET OF THE EXCAVATION.
5. CONTRACTOR SHALL COORDINATE ACCESS TO MANHOLES,
HANDHOLES, AND BUILDINGS WITH COR.
6. PRIOR TO INSTALLATION OF NEW CABLES IN EXISTING DUCTBANKS, THE
CONTRACTOR SHALL COORDINATE WITH THE COR TO DETERMINE
WHICH DUCT(S) SHALL BE USED. THE CONTRACTOR SHALL FIELD
VERIFY (ROD & MANDREL) EACH PATHWAY IDENTIFIED TO ENSURE IT IS
ADEQUATE FOR CABLE INSTALLATION. CONTRACTOR SHALL NOTIFY
COR IF AN EXISTING DUCT IDENTIFIED TO BE USED IS NOT ADEQUATE
FOR NEW CABLE INSTALLATION.
7. ALL COPPER SPLICING IN MANHOLES SHALL BE COORDINATED WITH
BASE COMMUNICATIONS STAFF.
8. IN MANHOLES/HANDHOLES WHERE FIBER OR COPPER CABLES ARE TO
BE SPLICED, PROVIDE MINIMUM 50' - 0" OF SLACK FOR FIBER CABLES
AND 20' OF SLACK FOR COPPER CABLES.
9. IN MANHOLES/HANDHOLES WHERE CABLES ARE TO BE ROUTED
THROUGH BUT NOT SPLICED, PROVIDE A MINIMUM OF 25' OF SLACK FOR
EACH FIBER CABLE.
10. FIBER AND COPPER CABLES SHALL BE INSTALLED IN NEW AND
EXISTING MANHOLES/HANDHOLES USING CABLE RACKS AND RACK
HOOKS.
11. FIBER AND COPPER SPLICE ENCLOSURES SHALL BE SECURELY
FASTENED TO MANHOLE/HANDHOLE CABLE RACKS AND RACKS HOOKS
USING ADJUSTABLE STAINLESS STEEL STRAPS.
12. FIBER AND COPPER SPLICES ARE ONLY ALLOWED WHERE INDICATED.
ADDITIONAL SPLICES ARE NOT ALLOWED WITHOUT WRITTEN DIRECTION
FROM COR.
13. PROVIDE PULL STRINGS IN ALL NEW AND EXISTING CONDUITS,
INCLUDING CONDUITS WHERE MULTICELL INNERDUCTS ARE TO BE
INSTALLED.
14. 4" - 3-CELL FABRIC INNERDUCT SHALL BE INSTALLED IN CONDUITS
WHERE INDICATED ON CONDUIT DETAILS. TERMINATE IN
MANHOLES/HANDHOLES PER MANUFACTURER INSTRUCTIONS AND
RECOMMENDATIONS.
1. BACKBONE CABLING SHALL BE INSTALLED IN AREA CABLE TRAYS AND
BACKBONE CONDUITS SHOWN. BACKBONE CABLING SHALL NOT BE
INSTALLED USING J-HOOKS OR ANY OTHER METHOD.
2. COMMUNICATION ROOMS HAVE BEEN LOCATED TO ENSURE THE
COPPER HORIZONTAL CABLING THROUGHOUT THE FACILITY DOES NOT
EXCEED 295 FEET TO MEET EIA/TIA STANDARDS. CONTRACTOR SHALL
ROUTE PATHWAYS AND CABLES TO ENSURE THIS DISTANCE IS NOT
EXCEEDED. CONTRACTOR SHALL NOTIFY COR PRIOR TO PATHWAY AND
CABLE INSTALLATION IF THERE ARE AREAS WHERE THE EXPECTED
DISTANCE MAY BE EXCEEDED.
3. HORIZONTAL CABLING SERVING WALL MOUNTED COMMUNICATIONS
OUTLETS SHALL BE ROUTED FROM COMMUNICATIONS OUTLET IN
MINIMUM 1-1/4” CONDUIT FROM EACH COMMUNICATIONS OUTLET TO
AREA CABLE TRAY, AND IN AREA CABLE TRAY TO DESIGNATED
COMMUNICATION ROOM. ROUTE CONDUITS IN FINISHED AREAS
CONCEALED IN WALL. WHERE COMMUNICATION OUTLETS ARE
INSTALLED IN EXPOSED UNFINISHED ROOMS, CONDUITS MAY BE
SURFACE MOUNTED. CONDUITS ROUTED EXPOSED SHALL BE PAINTED
TO MATCH ADJACENT SURFACES.
4. HORIZONTAL CABLING SERVING FLUSH MOUNTED COMBINATION
COMM/POWER FLOOR BOXES SHALL BE ROUTED FROM FLOOR BOX VIA
UNDERGROUND CONDUITS TO DESIGNATED COMMUNICATIONS ROOM.
PROVIDE TWO 1-1/4" CONDUITS FROM EACH FLOOR BOX TO NEAREST
WALL, TURN UP IN WALL, AND CONNECT TO NEAREST CABLE TRAY
ABOVE CEILING. SEE FLOOR BOX DETAILS.
5. HORIZONTAL CABLING SERVING SYSTEMS FURNITURE FLUSH MOUNTED
FLOOR BOX FEEDS SHALL BE ROUTED FROM OUTLET LOCATION ON
SYSTEMS FURNITURE, VIA SYSTEMS FURNITURE WIRE CHANNELS,
THROUGH FLOOR BOX, AND IN UNDERGROUND CONDUIT TO
DESIGNATED COMMUNICATIONS ROOM. PROVIDE TWO 1-1/4" CONDUITS
FROM EACH FLOOR BOX TO NEAREST WALL, TURN UP IN WALL, AND
CONNECT TO NEAREST CABLE TRAY ABOVE CEILING. PROVIDE FLEXIBLE
METAL CONDUIT FOR COMMUNICATION CABLES TO MODULAR
FURNITURE CONNECTION POINT.
6. HORIZONTAL CABLING SERVING WALL MOUNTED SYSTEMS FURNITURE
JUNCTION BOX FEEDS SHALL BE ROUTED FROM OUTLET LOCATION ON
SYSTEMS FURNITURE, VIA SYSTEMS FURNITURE WIRE CHANNELS,
THROUGH WALL JUNCTION BOX, IN CONDUIT TO CABLE TRAY, AND IN
CABLE TRAY TO DESIGNATED COMMUNICATIONS ROOM. PROVIDE
MINIMUM TWO 1-1/4” CONDUITS FROM EACH WALL MOUNTED SYSTEMS
FURNITURE JUNCTION BOX FEED TO AREA CABLE TRAY. PROVIDE
FLEXIBLE METAL CONDUIT FOR COMMUNICATION CABLES TO MODULAR
FURNITURE CONNECTION POINT.
7. REFER TO 'TG' SERIES SHEETS FOR GROUNDING AND BONDING
REQUIREMENTS.
8. REFER TO 'GI' SERIES SHEETS FOR FIRE AND SMOKE RATED PARTITION
LOCATIONS. REFER TO 'A-' SERIES SHEETS FOR PARTITION TYPES AND
DETAILS.
PROJECT OUTSIDE PLANT GENERAL
NOTES
PROJECT INSIDE PLANT GENERAL
NOTES
4"W X 12"D BT
AV/SCI
11' - 0" AFF
T
FFN
CATV
FO
FRONT
J
J
JUNCTION BOXES
RECESSED JUNCTION BOX, WALL MOUNTED
SURFACE JUNCTION BOX, WALL MOUNTED
JUNCTION BOX RECESSED IN FLOOR
JUNCTION BOX MOUNTED ABOVE CEILING, UON
J
J
SYMBOL MODIFIERS
X
LEGEND NOTES
1. EQUIPMENT IDENTIFIERS, MATCHING THOSE IN EQUIPMENT SCHEDULES,
ARE DISPLAYED INSIDE OF BRACKETS [ ].
2. SYMBOLS ORIENTATION DOES NOT IMPLY DEVICE OR EQUIPMENT
ORIENTATION. UNLESS NOTED AS SUCH. SEE REFLECTED CEILING PLANS
FOR LIGHT FIXTURE POSITIONS AND ORIENTATIONS.
3. SYMBOL SIZE DOES NOT IMPLY EQUIPMENT SIZE, UON.
4. MOUNTING HEIGHT INDICATED IN LEGEND AND ON THE DRAWINGS SHALL
BE THE DISTANCE MEASURED FROM THE CENTER OF THE DEVICE TO THE
FINISHED FLOOR.
5. NOT ALL SYMBOLS ARE USED.
6. REFER TO TYPICAL DETAILS ON TN500 SERIES DRAWINGS.
T
CATV
X
WAP
CPU
ORM
TIM
ZC
MC
S
S
UON UNLESS OTHERWISE NOTED
UTP UNSHIELDED TWISTED PAIR
VED VERTICAL EXHAUST DUCT
W WIRE OR WATT
AC ABOVE COUNTER
C RECESSED IN CEILING
W WALL MOUNTED, 48" AFF UON
WP WEATHERPROOF
ABBREVIATIONS
ACS ACCESS CONTROL SYSTEM
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AV AUDIO/VIDEO
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BEP BUILDING ENTRANCE PROTECTOR
BFG BELOW FINISHED GRADE
B-N BONDING NETWORK
BOT BOTTOM OF CABLE TRAY
C CONDUIT
CAT CATEGORY
CATV CABLE TELEVISION
CCN CONTRACTOR CLASSIFIED NETWORK (FIBER)
CCTV CLOSED CIRCUIT TELEVISION
CLAS CLASSIFIED NETWORK
COMM COMMUNICATIONS
COR CONTRACTING OFFICER'S REPRESENTATIVE
CPP COPPER HORIZONTAL PATCH PANEL
CRAC COMPUTER ROOM AIR CONDITIONING UNIT
CT CABLE TRAY
CU COPPER
EBC EQUIPMENT BONDING CONDUCTOR
EGC EQUIPMENT GROUNDING CONDUCTOR
EIA ELECTRONICS INDUSTRIES ASSOCIATIONS
EMT ELECTRICAL METALLIC TUBING
EPO EMERGENCY POWER OFF
ER EQUIPMENT ROOM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FO FIBER OPTIC
FPD FLAT PANEL DISPLAY
FPP FIBER OPTIC PATCH PANEL
FSCP FIRE SYSTEM CONTROL PANEL
FT FOOT OR FEET
GA GAUGE
GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED, GOVERNMENT INSTALLED
G OR GND GROUND
GFE GOVERNMENT FURNISHED EQUIPMENT
GFR GROUND FAULT RELAY
GFP GROUND FAULT PROTECTION
GRS GALVANIZED RIGID STEEL CONDUIT
HAC HOT AISLE CONTAINMENT
HDPE HIGH DENSITY POLYETHYLENE
HID HIGH INTENSITY DISCHARGE
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
IG ISOLATED GROUND
IN INCH OR INCHES
ISP INSIDE PLANT
K KILO
KCMIL THOUSAND CIRCULAR MILS
MAX MAXIMUM
MH MANHOLE
MIN MINIMUM
MM MULTI-MODE
MMF MULTI-MODE FIBER
MN/PA MASS NOTIFICATION/PUBLIC ADDRESS
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OSP OUTSIDE PLANT
PDS PROTECTIVE DISTRIBUTION SYSTEM
PDU POWER DISTRIBUTION UNIT
PR PAIR
PSI POUND PER SQUARE INCH
PVC POLYVINYL CHLORIDE
PWR POWER
R RADIUS
RGB RACK GROUND BAR
RGS RIGID GALVANIZED STEEL CONDUIT
RMC RIGID METAL CONDUIT
RU RACK UNITS
SCCR SHORT CIRCUIT CURRENT RATING
SCHED SCHEDULE
SCI SENSITIVE COMPARTMENTALIZED INFORMATION
STP SHIELDED TWISTED PAIR
SM SINGLE MODE
SPD SURGE PROTECTION DEVICE
SRG STATIC REFERENCE GRID
TB TELEPHONE BACKBOARD
TBB TELECOMMUNICATIONS BONDING BACKBONE
TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR
TGB TELECOMMUNICATIONS GROUND BAR
TMGB TELECOMMUNICATIONS MAIN GROUND BAR
TMH TELECOMMUNICATIONS MANHOLE
TR TELECOMMUNICATIONS ROOM
TS TOP SECRET
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION
TYP TYPICAL
UCLAS UNCLASSIFIED NETWORK
UL UNDERWRITERS' LABORATORIES
μm MICROMETER
TV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :4
A
M
T-001
TE
LE
C O
M M
U N
IC
A
TI
O
N S
L E
G E
N D
, A B
B R
E V
IA
TI
O N
S A
N D
G E
N E
R A
L N
O
TE
S
SMW
12801880
WJS EAK
1596300
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
101.1
101.1
FIBER PATCH PANEL PATCH PANEL 101.1-45
(3TR1.AD05-45)
FIBER PATCH PANEL PATCH PANEL 101.1-41
PATCH PANEL 101.1-35
PATCH PANEL 101.1-31
PATCH PANEL 101.1-27
IDENTIFIER NOTES:
1.
2.
3.
UTP/STP PATCH PANEL PORT IDENTIFIER:
LABELS UNDER EACH GROUP OF SIX PORTS:
101.1-45 p 01-06 to 103.1-45 p 01-06
OR
101.1-45 Ports 01-06 to 103.1-45 Ports 01-06
POSITION OF TOP OF PATCH PANEL IN RACK UNITS
# - ROOM NUMBER
"PORTS" CAN BE LABELED AS EITHER "p" OR THE ENTIRE WORD "ports" AS SPACE PERMITS.
PATCH PANEL LABELS MAY INCLUDE ADDITIONAL INFORMATION SUCH AS CABLE TYPE, SUB-PANEL NAME, NEAR-END TELECOMMUNICATIONS SPACE NAME, AND FAR-END TELECOMMUNICATIONS SPACE NAME.
TEXT MUST BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR MUST CONTRAST WITH
THE COLOR OF THE PIECE OF EQUIPMENT
[f].-[r] ports [PN1] to [f][s].[x][y]-[r] ports [PN2]
PORT NUMBER RANGE AT THE FAR-
END PATCH PANEL.
FAR-END PATCH
PANEL.
PORT NUMBER RANGE AT THE NEAR-END
PATCH PANEL.
FIBER PATCH PANEL PORT IDENTIFIER:
101.1-45 p 01-06 to 103.1-45 p 01-06
OR
101.1-45 Ports 01-06 to 103.1-45 Ports 01-06
PORT NUMBER RANGE AT THE FAR-END
PATCH PANEL.
FAR-END PATCH
PANEL.
PORT NUMBER RANGE AT THE NEAR-END
PATCH PANEL.
POSITION OF TOP OF PATCH PANEL IN RACK UNITS
# - ROOM NUMBER
IDENTIFIER NOTES:
1.
2.
3.
"PORTS" CAN BE LABELED AS EITHER "p" OR THE ENTIRE WORD "ports" AS SPACE PERMITS.
PATCH PANEL LABELS MAY INCLUDE ADDITIONAL INFORMATION SUCH AS CABLE TYPE, SUB-PANEL NAME, NEAR-END TELECOMMUNICATIONS SPACE NAME, AND FAR-END TELECOMMUNICATIONS SPACE
NAME.
TEXT MUST BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR MUST CONTRAST
WITH THE COLOR OF THE PIECE OF EQUIPMENT
[f].-[r] ports [PN1] to [f][s].[x][y]-[r] ports [PN2]
PATCH PANEL IDENTIFIER:
IN ROOM LABELING
OUTSIDE OF TR.101.1-45
THE ROOM LABELING
101.1-45
POSITION OF TOP OF PATCH PANEL
IN RACK UNITS
IDENTIFIER NOTES:
1.
2.
# - INCREMENTAL NUMBER
# - ROOM NUMBER
ALTHOUGH THE PATCH PANELS OCCUPY MULTIPLE RACK UNIT POSITIONS, EACH PATCH PANEL IS IDENTIFIED BY THE
RACK UNIT POSITION OF THE TOP OF THE PATCH PANEL.
TEXT MUST BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR MUST CONTRAST WITH THE
COLOR OF THE PIECE OF EQUIPMENT
[f].[#]-[r]
RACK/CABINET IDENTIFIER:
IN ROOM LABELING
OUTSIDE OF TR.101.1
THE ROOM LABELING
101.1
# - INCREMENTAL NUMBER
# - ROOM NUMBER
IDENTIFIER NOTES:
1. RACK/CABINET IDENTIFIER MUST BE LABELED ON THE FRONT AND REAR IN PLAIN SIGHT PREFERABLY
CENTERED ON RACK/CABINET.
2. TEXT MUST BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR MUST CONTRAST
WITH THE COLOR OF THE PIECE OF EQUIPMENT.
[f].[#]
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :4
A
M
T-002
TE
LE
C O
M M
U N
IC
A
TI
O
N S
L A
B E
LI
N
G
SMW
12801881
WJS EAK
1596300
NOT TO SCALE
A1
RACK/CABINET ID DETAIL
NOT TO SCALE
A2
UTP/STP PATCH PANEL PORT IDENTIFIER
NOT TO SCALE
B2
FIBER PATCH PANEL PORT IDENTIFIER
NOT TO SCALE
C2
PATCH PANEL IDENTIFIER
NOT TO SCALE
C1
RACK/CABINET IDENTIFIER
GENERAL NOTES
1. TELECOMMUNICATIONS LABELING CONVENTIONS FOLLOW THE
GUIDELINES OF ANSI/TIA-606-C. ANY TELECOMMUNICATIONS EQUIPMENT
REQUIRING LABELS NOT SPECIFICALLY ILLUSTRATED ON THESE
DRAWINGS MUST FOLLOW THIS STANDARD UNLESS OTHERWISE NOTED.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
AD05-45:01 / H101.01.D
[f] [s] . [x] [y] - [r] : [P1] / [sa] . [t] [p]
CABLE IDENTIFIER:
CABINET/FRAME COLUMN IDENTIFIER
CABINET/FRAME ROW IDENTIFIER
IDENTIFIER NOTES:
1. ROOM IDENTIFIER CAN BE OMITTED WHEN THE ROOM NAME IS OBVIOUS TO SOMEONE IN THE ROOM.
2. "PORTS" CAN BE LABELED AS EITHER "p" OR THE ENTIRE WORD "ports" AS SPACE PERMITS.
3. PATCH PANEL LABELS MAY INCLUDE ADDITIONAL INFORMATION SUCH AS CABLE TYPE, SUB-PANEL NAME, NEAR-END
TELECOMMUNICATIONS SPACE NAME, AND FAR-END TELECOMMUNICATIONS SPACE NAME.
4. TEXT SHALL BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR SHALL CONTRAST WITH THE COLOR OF THE
PIECE OF EQUIPMENT
# - ROOM FLOOR IDENTIFIER
ROOM IDENTIFIER:
ER - EQUIPMENT ROOM
TR - TELECOMMUNICATIONS ROOM
POSITION OF TOP OF PATCH PANEL IN RACK UNITS
PORT NUMBER AT THE NEAR-END PATCH
PANEL.
OUTLET POSITION
OUTLET NUMBER
ROOM NUMBER:
AS IDENTIFIED ON ARCH FLOOR PLAN
AD05-45:01 / AG03-45:01
[f] [s] . [x] [y] - [r] : [P1] / [f] [s] . [x] [y] - [r] : [P2] CABLE IDENTIFIER:
CABINET/FRAME COLUMN IDENTIFIER
CABINET/FRAME ROW IDENTIFIER
IDENTIFIER NOTES:
1. ROOM IDENTIFIER CAN BE OMITTED WHEN THE ROOM NAME IS OBVIOUS TO SOMEONE IN THE ROOM.
2. "PORTS" CAN BE LABELED AS EITHER "p" OR THE ENTIRE WORD "ports" AS SPACE PERMITS.
3. PATCH PANEL LABELS MAY INCLUDE ADDITIONAL INFORMATION SUCH AS CABLE TYPE, SUB-PANEL NAME, NEAR-END
TELECOMMUNICATIONS SPACE NAME, AND FAR-END TELECOMMUNICATIONS SPACE NAME.
4. TEXT SHALL BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR SHALL CONTRAST WITH THE COLOR OF THE
PIECE OF EQUIPMENT
# - ROOM FLOOR IDENTIFIER
ROOM IDENTIFIER:
ER - EQUIPMENT ROOM
TR - TELECOMMUNICATIONS ROOM
POSITION OF TOP OF PATCH PANEL IN RACK UNITS
AD05-45:01-06 / AG03-45:01-06
OR
PORT NUMBER AT THE NEAR-END PATCH
PANEL.
PORT NUMBER AT THE FAR-END PATCH
PANEL.
FAR-END PATCH
PANEL.
3ER1.VF1-001
[f] [s] . [vf] [#] - [#]TERMINATION BLOCK IDENTIFIER:
VOICE FIELD
INCREMENTAL NUMBER
IDENTIFIER NOTES:
1. TEXT SHALL BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR SHALL CONTRAST WITH THE COLOR OF
THE PIECE OF EQUIPMENT
# - ROOM FLOOR IDENTIFIER
ROOM IDENTIFIER:
ER - EQUIPMENT ROOM
TR - TELECOMMUNICATIONS ROOM
PORT NUMBER OF TERMINATION BLOCK
3TR1.AD05-45.01
[f] [s] . [x] [y] - [r] . [#]OUTLET PORT IDENTIFIER:
CABINET/FRAME COLUMN IDENTIFIER
CABINET/FRAME ROW IDENTIFIER
IDENTIFIER NOTES:
1. TEXT SHALL BE EASILY READ WITH UPPER CASE LETTERING AND THE LABEL COLOR SHALL
CONTRAST WITH THE COLOR OF THE PIECE OF EQUIPMENT
# - ROOM FLOOR IDENTIFIER
ROOM IDENTIFIER:
ER - EQUIPMENT ROOM
TR - TELECOMMUNICATIONS ROOM
POSITION OF TOP OF PATCH PANEL IN RACK UNITS
PORT NUMBER OF PATCH PANEL
3TR1.AD05-
45.01
3TR1.AD05-
45.02
3TR1.AD05-
45.03
3TR1.AD05-
45.04
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :4
A
M
T-003
TE
LE
C O
M M
U N
IC
A
TI
O
N S
L A
B E
LI
N
G
SMW
12801882
WJS EAK
1596300
GENERAL NOTES
1. TELECOMMUNICATIONS LABELING CONVENTIONS FOLLOW THE
GUIDELINES OF ANSI/TIA-606-C. ANY TELECOMMUNICATIONS EQUIPMENT
REQUIRING LABELS NOT SPECIFICALLY ILLUSTRATED ON THESE
DRAWINGS MUST FOLLOW THIS STANDARD UNLESS OTHERWISE NOTED.
NOT TO SCALE
A3
TYPICAL CABLE IDENTIFIER - PATCH PANEL TO OUTLET
NOT TO SCALE
C1
TYPICAL CABLE IDENTIFIER - PATCH PANEL TO PATCH PANEL
NOT TO SCALE
C3
TYPICAL TERMINATION BLOCK IDENTIFIER
NOT TO SCALE
A1
TYPICAL OUTLET PORT IDENTIFIER
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
E
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT UGT UGT UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
U G
T U
G T
U G
T U
G T
U G
T U
G T
U G
T U
G T
U G
T U
G T
UG
T
COMM
COMM
COMM
COMM
U G
T U
G T
U G
T U
G T
U G
T
U G
T U
G T
U G
T U
G T
U G
T U
G T
U G
T U
G T
U G
T
UG
T
UGT
UGT
UGT
COMM COMM
U G
T U
G T
U G
T U
G T
UG
T
UG
T
COMM
COMM
R-20
R-21
R-22
R-23
HH
R-24 R-25
R-26
R-27
R-28
R-29 R-30
R-30A R-30B
BLDG
R-30C
BLDG
R-30D R-30E
BLDG
R-31
R-32
R-33
R-34
NEW
R-34A
BLDG
BIRD
RADAR
BLDG
NEW
R-34B
NEW
R-34C
RUNWAY 23
RUNWAY 05
RUNWAY 14
RUNWAY 32
PAR
43086
1 2
2 4
1 2
1 2
TS101
A1
TS102
A1
TS101
D1
A1 TELECOMMUNICATIONS SITE PLAN - OVERALL
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
1" = 400'
TS100
SCALE IN FEET
400' 800'
PLAN
NORTH
WORK NOTES
GENERAL NOTES
1. UTILITY OUTAGES SHALL BE KEPT TO A MINIMUM. ALL OUTAGES
SHALL BE LIMITED TO AFTER HOURS AND WEEKENDS.
COORDINATE ALL UTILITY OUTAGES WITH THE COR.
2. ALL UTILITIES ARE NOT INDICATED ON THIS DRAWING. THE
SUCCESSFUL CONTRACTOR WILL BE PROVIDED BASE UTILITY/GIS
DRAWINGS OF ALL AFFECTED AREAS UPON CONTRACT AWARD.
CONTRACTOR SHALL COORDINATE NEW DUCTBANK WITH ALL
EXISTING UTILITIES.
3. ROUTING SHOWN IS DIAGRAMMATIC. ROUTE CONDUITS TO AVOID
STRUCTURES AND ALL OTHER UTILITIES.
4. THE CONTRACTOR SHALL FIELD-CHECK ALL EXISTING
CONDITIONS AND BE THOROUGHLY FAMILIAR WITH THE SITE
BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES IN THE
DRAWINGS SHALL BE IMMEDIATELY REPORTED TO THE COR
BEFORE ANY FURTHER WORK COMMENCES.
5. ALL CONDUIT BENDS SHALL BE LONG SWEEP BENDS WITH
MINIMUM OF 10X THE INTERNAL DIAMETER OF THE CONDUIT.
6. NO SECTION OF CONDUIT SHALL CONTAIN MORE THAN (2) 90°
BENDS.
7. WHEN COMMUNICATIONS CONDUIT IS INSTALLED IN THE SAME
TRENCH AS POWER CONDUIT A 12" SEPARATION SHALL BE
MAINTAINED THROUGHOUT.
8. REFER TO TS700 SERIES DRAWINGS FOR ADDITIONAL
INFORMATION.
1. PROVIDE FIBER CABLE SPLICE, REFER TO TS702 FOR ADDITIONAL
INFORMATION.
2. PROVIDE COPPER CABLE SPLICE, REFER TO TS703 FOR
ADDITIONAL INFORMATION.
3. PROVIDE 1X2, 4" CONDUIT, CONCRETE ENCASED DUCTBANK,
REFER TO DETAIL C3/TS501.
4. PROVIDE NEW TYPE 4 COMMUNICATION HANDHOLE, REFER TO
DETAIL C3/ TS502.
5. PROVIDE 2X3, 4" CONDUIT, CONCRETE ENCASED DUCTBANK,
REFER TO DETAIL C4/ TS501.
6. PROVIDE NEW TYPE 6 COMMUNICATION MANHOLE, REFER TO
DETAIL C1/ TS502.
7. PROVIDE DIRECTIONAL BORING UNDER EXISTING AIRFIELD
PAVEMENT. TYPICAL THIS AREA.
IS
SU
ED
F
OR
B
ID
/18
/20
E
E E
E E
E E
E E
E
E
E
E
CATV
CATV
CATV
CATV
CATV
CATV
6TH AVENUE
ATCT
FFE 28.00
RMD
FFE 28.00
MTRACON
FFE 28.00
X
XX
X X
X
X X
X
XXXX
X X
X X
X X
X X
X X
X X
X X
X X
X
X X X X
X X
X
X X
X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXX
X
X
NO
P
AR
KI
NG
NO PARKING
X
XX
X X
X
X X
X
X
X
XXXX
X X
X X
X X
X X
X X
X X
X X
X X
X
X X X X
X X
X
X X
X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXX
MHMH
EXISTING
MH012
EXISTING
MH013
EXISTING
MH-C02
COMM COMM
C O
M M
C O
M M
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
COMM COMM COMM
COMM COMM COMM
C O
M M
COMM
C O
M M
ROOM
10 4
ROOM
MH
MH
MH
MH
EXISTING
MH014
EXISTING
MH-C08
EXISTING
MH015
COMM COMM COMM
EXISTING
MH-C04
EXISTING
MH-C06
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
TS101
A1 TELECOMMUNICATIONS SITE PLAN - AREA 1
WORK NOTES
1" = 30' 0
SCALE IN FEET
30' 60'
MA
TC
H
LIN
E
AR
EA
1A
PLAN
NORTH
1. UTILITY OUTAGES SHALL BE LIMITED TO AFTER HOURS AND
WEEKENDS. COORDINATE ALL UTILITY OUTAGES WITH THE COR.
2. ALL UTILITIES ARE NOT INDICATED ON THIS DRAWING. THE
SUCCESSFUL CONTRACTOR WILL BE PROVIDED BASE UTILITY/GIS
DRAWINGS OF ALL AFFECTED AREAS UPON CONTRACT AWARD.
CONTRACTOR SHALL COORDINATE NEW DUCTBANK WITH ALL
EXISTING UTILITIES.
3. ROUTING SHOWN IN DIAGRAMMATIC ROUTE CONDUITS TO AVOID
STRUCTURES AND ALL OTHER UTILITIES.
4. THE CONTRACTOR SHALL FIELD-CHECK ALL EXISTING
CONDITIONS AND BE THOROUGHLY FAMILIAR WITH THE SITE
BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES IN THE
DRAWINGS SHALL BE IMMEDIATELY REPORTED TO THE COR
BEFORE ANY FURTHER WORK COMMENCES.
5. ALL CONDUIT BENDS SHALL BE LONG SWEEP BENDS WITH
MINIMUM OF 10X THE INTERNAL DIAMETER OF THE CONDUIT.
6. NO SECTION OF CONDUIT SHALL CONTAIN MORE THAN (2) 90°
BENDS.
7. WHEN COMMUNICATIONS CONDUIT IS INSTALLED IN THE SAME
TRENCH AS POWER CONDUIT A 12" SEPARATION SHALL BE
MAINTAINED THROUGHOUT.
8. EXISTING CONDITIONS SHOWN INCLUDE CURRENT PROJECT P-235
AND BUILDING 144 DEMOLITION DESIGN DOCUMENTS.
1. PROVIDE 2X3 4" CONDUIT, CONCRETE ENCASED DUCTBANK FROM
EXISTING MH-C02 TO COMM RM 105. REFER TO DETAIL C4/TS501.
2. PROVIDE 2X2 4" CONDUIT, CONCRETE ENCASED DUCTBANK FROM
EXISTING MH-C04 TO COMM RM 2109. REFER TO DETAIL A4/TS501.
3. PROVIDE TYPE 4, TRAFFIC RATED, COMMUNICATIONS HANDHOLE,
REFER TO DETAIL C3/TS502.
4. PROVIDE TYPE 7, NON-DELIBERATE TRAFFIC RATED (TIER 22),
COMMUNICATIONS HANDHOLE. REFER TO DETAIL A4/TS502.
5. PROVIDE 2" DIRECT BURIED CONDUIT FOR SECURITY CABLING.
6. FULL HEIGHT PEDESTRIAN GATE, PROVIDE CONDUIT AND
HANDHOLE ROUGH-IN FOR ELECTRONIC SECURITY SYSTEMS AS
NOTED. REFER TO DETAIL C1/TY503 FOR ADDITIONAL
INFORMATION.
7. VEHICULAR GATE, PROVIDE CONDUIT AND HANDHOLE ROUGH-IN
FOR ELECTRONIC SECURITY SYSTEMS AS NOTED.
8. TIE NEW CONDUIT DUCTBANK INTO EXISTING HANDHOLE/
MANHOLE. CUT AND PATCH EXISTING STRUCTURE AS REQUIRED
TO ACCOMMODATE NEW CONDUIT. COVER, PROTECT, AND KEEP
SAFE EXISTING CABLING AS REQUIRED.
9. PROVIDE TYPE 4, TRAFFIC RATED, COMMUNICATIONS MANHOLE,
REFER TO DETAIL A3/TS502.
10. PROVIDE 1" DIRECT BURIED CONDUIT FOR SECURITY CABLING.
11. NEW DUCTBANK TO BE INSTALLED IN PARALLEL TO EXISTING
TELECOM DUCTBANK. COORDINATE ROUTING OF NEW DUCTBANK
TO NOT DISRUPT EXISTING UTILITIES.
GENERAL NOTES
D1 TELECOMMUNICATIONS SITE PLAN - AREA 1A
1" = 30' 0
SCALE IN FEET
30' 60'
PLAN
NORTH
MA
TC
H
LIN
E
AR
EA
1A
MA
TC
H
LIN
E
SH
EE
T
TS
KEY PLAN
TS102
TS101-A
TS101
PLAN
NORTH
TN421
A3
TN411
A3
IS
SU
ED
F
OR
B
ID
/18
/20
COMM
CO
M
M C
O M
M C
O M
M C
O M
M C
O M
M
COMM
C O
M M
C O
M M
C O
M M
COM
M
C O
M M
C O
M M
C O
M M
COMM COMM COMM COMM COMM
XXX
X X X
X X X
X X
X X
X X
X
X X
X X
X
NO PARKING
LA
NE
LANE
NO
P
AR
KI
NG
LANE
FIRE
NO PARKING
P
FI
RE P
FIRE
P
LANE
FIRE
P
X X
X
X
X
X X
MH
MH
MH
BASE NODE
VAULT
EXISTING
MH014
EXISTING
MH-C08
EXISTING
MH015
ROOM 108
AIRFIELD
OPERATIONS
BUILDING
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
IS
SU
ED
F
OR
B
ID
/18
/20
TS102
MA
TC
H
LIN
E
SH
EE
T
TS
1, AR
EA
1A
PLAN
NORTH
A1 TELECOMMUNICATIONS SITE PLAN - AREA 2
1" = 30' 0
SCALE IN FEET
30' 60'
GENERAL NOTES
WORK NOTES
1. PROVIDE 3X3 4" CONDUIT DUCTBANK FROM EXISTING MH014 TO BASE
NODE VAULT, REFER TO DETAIL A3/TS501.
2. PROVIDE 4X3 4" CONDUIT DUCTBANK FROM EXISTING MH015 TO BASE
NODE VAULT, REFER TO DETAIL A1/TS503.
3. PROVIDE 2X3 4" CONDUIT DUCTBANK FROM EXISTING MH R21 TO BASE
NODE VAULT, REFER TO DETAIL C4/TS501.
4. PROVIDE (1) 4" DIRECT BURIED CONDUIT FROM TRAILER PEDESTAL TO
COMMUNICATIONS MANHOLE.
5. NEXGEN TRAILER PEDESTAL, PROVIDE (1) 6STR. INDOOR/OUTDOOR SM
FOC WITH TFOCA CONNECTOR AND (2) CAT. 6 INDOOR/OUTDOOR CABLES
WITH 8-PIN CONNECTORS. CABLES SHALL TERMINATE IN BASE NODE
ROOM 156. REFER TO DETAIL A3/TS503 FOR CABINET AND PEDESTAL
REQUIREMENTS.
6. RECONFIGURE EXISTING CONDUIT STUB OUT, TIE NEW CONDUIT
DUCTBANK INTO EXISTING HANDHOLE/ MANHOLE. CUT AND PATCH
EXISTING STRUCTURE AS REQUIRED TO ACCOMMODATE NEW CONDUIT.
COVER, PROTECT, AND KEEP SAFE EXISTING CABLING AS REQUIRED.
7. PROVIDE TYPE 6, AIRFIELD RATED COMMUNICATIONS MANHOLE, REFER
TO DETAIL A1/TS502.
8. VEHICULAR GATE, PROVIDE CONDUIT AND HANDHOLE ROUGH-IN FOR
ELECTRONIC SECURITY SYSTEMS AS NOTED.
9. PROVIDE 2" DIRECT BURIED CONDUIT FOR SECURITY CABLING.
10. PROVIDE 1" DIRECT BURIED CONDUIT FOR SECURITY CABLING.
11. PROVIDE TYPE 8, NON-DELIBERATE TRAFFIC RATED (TIER 22),
COMMUNICATIONS HANDHOLE. REFER TO DETAIL A4/TS502.
TS101-A
TS101
PLAN
NORTH
KEY PLAN
TS102
REFER TO TS100
FOR CONTINUATION
1. UTILITY OUTAGES SHALL BE LIMITED TO AFTER HOURS AND
WEEKENDS. COORDINATE ALL UTILITY OUTAGES WITH THE COR.
2. ALL UTILITIES ARE NOT INDICATED ON THIS DRAWING. THE
SUCCESSFUL CONTRACTOR WILL BE PROVIDED BASE UTILITY/GIS
DRAWINGS OF ALL AFFECTED AREAS UPON CONTRACT AWARD.
CONTRACTOR SHALL COORDINATE NEW DUCTBANK WITH ALL
EXISTING UTILITIES.
3. ROUTING SHOWN IN DIAGRAMMATIC ROUTE CONDUITS TO AVOID
STRUCTURES AND ALL OTHER UTILITIES.
4. THE CONTRACTOR SHALL FIELD-CHECK ALL EXISTING
CONDITIONS AND BE THOROUGHLY FAMILIAR WITH THE SITE
BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES IN THE
DRAWINGS SHALL BE IMMEDIATELY REPORTED TO THE COR
BEFORE ANY FURTHER WORK COMMENCES.
5. ALL CONDUIT BENDS SHALL BE LONG SWEEP BENDS WITH
MINIMUM OF 10X THE INTERNAL DIAMETER OF THE CONDUIT.
6. NO SECTION OF CONDUIT SHALL CONTAIN MORE THAN (2) 90°
BENDS.
7. WHEN COMMUNICATIONS CONDUIT IS INSTALLED IN THE SAME
TRENCH AS POWER CONDUIT A 12" SEPARATION SHALL BE
MAINTAINED THROUGHOUT.
8. EXISTING CONDITIONS SHOWN INCLUDE CURRENT PROJECT P-235
AND BUILDING 144 DEMOLITION DESIGN DOCUMENTS.TN401
A3
TN404
A3
M
IN
TOP OF PAVEMENT SUBGRADE OR GRADE
SELECT BACKFILL
WARNING TAPE,
6" BELOW GRADE
3" 3" 3"
NOTES:
1. USE PLASTIC CONDUIT SPACERS AT 5'-0" OC.
3000 PSI CONCRETE
4" SCHEDULE 40
PVC CONDUIT
FABRIC INNERDUCT
M
IN
3" 3" 3"
NOTES:
1. USE PLASTIC CONDUIT SPACERS AT 5'-0" OC.
8 9
3000 PSI CONCRETE
4 5 6
FABRIC INNERDUCT
1 2
TOP OF PAVEMENT SUBGRADE OR GRADE
SELECT BACKFILL
WARNING TAPE,
6" BELOW GRADE
4" SCHEDULE 40
PVC CONDUIT
3"
M
IN
3" 3"
WARNING TAPE, 6" BELOW
GRADE
PVC CONDUIT
SIZE AS INDICATED
3" 3"
3"
FABRIC INNERDUCT
SELECT BACKFILL
3000 PSI CONCRETE
TOP OF PAVEMENT SUBGRADE OR GRADE
NOTES:
1. USE PLASTIC CONDUIT SPACERS AT 5'-0" OC.
1 2
24"R
MIN
NOTES:
PVC COATED GRS
CONDUIT (TYP)
PVC COATED GRS CONDUIT
ADAPTER (TYP)
PVC COATED GRS
CONDUIT ELBOW (TYP)
ENCASE WITH A MIN
OF 3" CONCRETE, AS
SHOWN, FOR STABILITY
SCHED 40 PVC COUPLING OR
ADAPTER, AS APPLICABLE (TYP)
SCHED 40 PVC AS REQUIRED (TYP)
1. THIS DETAIL IS A TYPICAL MULTIDUCT ARRANGEMENT.
SLOPE DOWN
1/8" PER FT MIN
CAPPED BUSHING
BEVEL TOP EDGE
OF CONCRETE2" OR
EQUIVALENT
PAD
2"
GRS CONDUIT
ADAPTER
R MIN24
M
IN
36"
4"
TRANSITION COUPLING
GRS OR IMC
DIRECT BURIED, PVC CONDUIT
TOP OF
CONCRETE
M
IN
3" 3" 3"
NOTES:
1. USE PLASTIC CONDUIT SPACERS AT 5'-0" OC.
3000 PSI CONCRETE
4 5
FABRIC INNERDUCT
1 2
TOP OF PAVEMENT SUBGRADE OR GRADE
SELECT BACKFILL
WARNING TAPE,
6" BELOW GRADE
4" SCHEDULE 40
PVC CONDUIT
3"
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :0
A
M
TS501
TE
LE
C O
M M
U N
IC
A
TI
O
N S
S
IT
E D
E
TA
IL
S
SMW
12801886
WJS EAK
1596300
NOT TO SCALE
C3
TYPICAL 1 X 2 CONCRETE ENCASED DUCTBANK
NOT TO SCALE
A3
TYPICAL 3 X 3 CONCRETE ENCASED DUCTBANK
NOT TO SCALE
A4
TYPICAL 2X2 CONCRETE ENCASED DUCTBANK
NOT TO SCALE
A1
TYPICAL CONCRETE ENCASED DUCTBANK RISER
NOT TO SCALE
C1
TYPICAL DIRECT BURIED STUBBED CONDUIT RISER
NOT TO SCALE
C4
TYPICAL 2 X 3 CONCRETE ENCASED DUCTBANK
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
A
#5 REINF. AT 6" EW
TOP, SIDES & BOTTOM
FOR MANHOLE FRAME & COVER, SEE FED.
SPEC. A-A-60005 FIG. 4, SIZE 28 AND FIG.
12, SIZE 28 RESPECTIVELY
SECTION A-A
BC 6"
BRICK COLLAR LINED UP
WITH CEMENT MORTAR
GROUND ROD & CLAMP
10"
SLOPE 1:40 TO SUMP
7/8" ∅ PULLING-IN IRON
DUCT ENTRANCE
6"
A
7/8" ∅ PULLING-IN IRON
DUCT ENTRANCE
12" x 12" x 10" DEEP SUMP
PLAN
MANHOLE DIMENSIONS
TYPE
A B C (AT HIGH PT.)
6"
6" 1'-0"
6"
6"
6"
6'-0" 6'-0" 6'-6"
A
B
LAP REINF. 24" (TYP.)
WATERSTOP AT ALL
CONSTR. JTS. (TYP.)
NOTES:
1. FOR DETAILS OF CABLE RACKS, DUCT ENTRANCE
AND PULLING-IN IRONS, SEE DETAIL C4.
2. MINIMUM CONCRETE COMPRESSIVE STRENGTH
SHALL BE 3000 PSI.
3. DUCT ENTRANCE. LOCATION TO BE AS INDICATED
ON THE PROJECT DRAWING.6'-6"8'-0"6'-0"
12" x 12" x 10" DEEP SUMP
7/8"∅ PULLING-IN IRON
DUCT ENTRANCE. LOCATION
TO BE AS INDICATED
PLAN
A
B
8"
A A
CONCRETE OR BLACK
TOP ROADWAY
SLOPE 1:40 TO SUMP
GROUND ROD & CLAMP
DUCT ENTRANCE
FOR MANHOLE FRAME & COVER, SEE FED. SPEC.
A-A-60005, FIG. 1, SIZE 30A AND FIG. 8, SIZE 30A,
RESPECTIVELY
BRICK COLLAR LINED UP
WITH CEMENT MORTAR
8"
10"
B
SECTION A-A
#5 @ 6" EW, T&B
#4 @ 6" EW EF
7/8"∅ PULLING-IN IRON
#4 @ 6" T&B
C
8"
8"
8"
8"
LAP REINF. 24" (TYP.)
6" MIN.
NOTES:
1. MANHOLE AND COVERS ARE DESIGNED
FOR MAXIMUM WHEEL LOAD IN
ACCORDANCE WITH AASHTO HS20-44.
2. FOR DETAILS OF CABLE RACKS, DUCT
ENTRANCE AND PULLING-IN IRONS, SEE
DETAIL C4.
3. MINIMUM CONCRETE COMPRESSIVE
STRENGTH SHALL BE 3000 PSI.
4. DUCT ENTRANCE. LOCATION TO BE AS
INDICATED ON THE PROJECT DRAWING.
WATERSTOP AT ALL
CONSTR. JTS. (TYP.)
MANHOLE DIMENSIONS
TYPE
6'-0" 6'-0" A
8'-0" 6'-0"
B C (AT HIGH PT.)
6'-6" 6'-6"
5/8" TK PL-PROVIDE LIFTING HOLES
SECTION A-A
#5 @ 6" E.W. E.F. TOP,
BOTTOM & SIDES
CONCRETE PAVING
7/8"∅ PULLING-IN IRON
SLOPE 1:40 TO SUMP
C
B
1/4"
COVER DETAIL
7/8"∅ PULLING-IN IRON
5/8" X 5/8" BAR
F/45 1/2 @ 6
1/2" CLEAR
5/16"
2'-0" OPENING
PLAN
B
A
8"
A
BRICK COLLAR LINED UP
WITH CEMENT MORTAR
GROUND ROD & CLAMP
8"
DUCT ENTRANCE. LOCATION
TO BE AS INDICATED
FOR MANHOLE FRAME, SEE FED
SPEC. A-A-60005, FIG 3, SIZE 24A,
STYLE B, 4" FLANGE
12" X 12" X 10" DEEP SUMP
A
8"
8"
8"
8"
10"
8"
(SEE NOTE 3)
4" X 3/4" BARS
LAP REINF. 24" (TYP.)
NOTES:
1. MANHOLE AND COVERS ARE DESIGNED FOR MAXIMUM
WHEEL LOAD OF 50,000 LB OR DUAL WHEEL LOAD OF
90,000 LB.
2. FOR DETAILS OF CABLE RACKS, DUCT ENTRANCE AND
PULLING-IN IRONS, SEE DETAIL C4.
3. COVER SHALL BE MADE OF STRUCTURAL STEEL
CONFORMING TO ASTM A 36/A 36M.
4. MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL
BE 3000 PSI.
5. DUCT ENTRANCE. LOCATION TO BE AS INDICATED ON
THE PROJECT DRAWING.
SUMP
TYP
10"
4" 1'-8"
4"
WATERSTOP AT ALL
CONSTR. JTS. (TYP.)
MANHOLE DIMENSIONS
TYPE
6'-0" 6'-0" A
8'-0" 6'-0"
B C (AT HIGH PT.)
6'-6" 6'-6"
6"
L3 1/2 X 3 1/2 X 1/4
ST3 X 6.25
L7 X 4 X 3/8 X 9"
LONG
SLOPE FL. TO SUMP
7/8"∅ PULLING-
IN IRON
1'-0"
A
L 6 X 3 1/2 X 5/16 1/4"
6" X 3/8" X 4'-6" PL
PAVING
3"
6"
10" A 10"
#4 @ 12" E.W. & E.F.
SIDES & BOTTOM
SECTION A-A
A
1'-0"
6"
10" A
10"
L7 X 4 X 3/8 X 9" LONG
W8 X 40 REMOVABLE
SECTION B-B
1'-0"X1'-0"X6" SUMP
GROUND ROD & CLAMP
#4 AT 12" E.W. E.F.
SIDES & BOTTOM
1 1/4" X 1/8" ANCHOR
@ 1'-6" O.C.
PAVING OR GRADE
1/2" P.E.J. ALL AROUND
SECTION C-C
3/16 T
ST 3 X 6.25
TYPE 3, 1'-1"
TYPE 4, 1'-7"
L 3 1/2X3 1/2X1/4
1 1/4" X 1/8
ANCHOR @
1'-6" O.C.
1/2"∅ STEEL ROD
2" 4"
3"
1"
6"6"
3"
C
C
7"
9"
B
B
AA
3" X 3/8" X 8" PL
REMOVABLE W 8 X 40
SUMP
1/2" ∅ PLUG WELD AT 6" O.C.
1/2" ∅ PLUG WELD
3" X 3/8" X 4'-6" PL
HINGE-WELDED TO FRAME & COVER
1/2" ∅ PLUG WELD AT 6" O.C.
PL
PLAN
DIMENSIONSHANDHOLE
TYPE
4'-0" 3'-0"
A
(SEE NOTE 4)#4 @ 12"
E.W. & E.F.
1/2" PL
VARIES
NOTES:
1. ENTRANCE OF DUCTS INTO HANDHOLE MAY BE MADE ON
SIDE FACES OR CORNERS AS REQUIRED.
2. FOR DETAILS OF CABLE RACKS, DUCT ENTRANCE AND
PULLING-IN IRONS, SEE DETAIL C4.
3. HANDHOLE AND COVER IS DESIGNED FOR MAXIMUM
SINGLE WHEEL LOAD OF 50,000 LB. OR DUAL WHEEL
LOAD OF 90,000 LB.
4. COVER SHALL BE MADE OF STRUCTURAL STEEL
CONFORMING TO ASTM A 36/A 36M.
5. MINIMUM COMPRESSIVE STRENGTH OF CONCRETE
SHALL BE 3000 PSI.
6. DUCT ENTRANCE. LOCATION TO BE AS INDICATED ON
THE PROJECT DRAWING.
NOTE: STIFFENERS SHOWN
TYP. BOTH SIDES
WATERSTOP AT ALL
CONSTR. JTS. (TYP.)
30" X 48" X 24" DEEP
24" X 36" X 24" DEEP
12" X 24" X 24" DEEP
12" X 18" X 24" DEEP
12" X 12" X 24" DEEP
HANDHOLE SIZING
1. HOUSING SHALL BE A POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS
REINFORCING WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 PSI.
2. COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 15,000 LBS OVER A 10" x 10" AREA.
3. PROVIDE STAINLESS STEEL BOLTS AND INSERTS.
4. PROVIDE WITH (2) 2 1/2" MOUSEHOLES.
5. PROVIDE LABEL "ELECTRICAL" FOR POWER HANDHOLES OR "TELEPHONE" FOR TELEPHONE
HANDHOLES, OR AS INDICATED.
6. DUCT ENTRANCE. LOCATION TO BE AS INDICATED ON THE PROJECT DRAWING.
SECTIONAL
BOX WHEN
REQUIRED
HANDHOLE REQUIREMENTS
TYPE
CRUSHED ROCK
6"
COMPACTED
EARTH
PULL SLOT
SKID
RESISTANT
SURFACE
STAINLESS STEEL HEX
BOLT AND WASHER
BOX AND
COVER6"
CONCRETE RING
AROUND BOX 10"
6"
LABEL
WALL OF MANHOLE
TYPICAL CABLE RACK
TYPICAL DUCT ENTRANCE
DUCT
INSIDE FACE OF MANHOLE
3"
DETAIL OF PULLING-IN IRON
7" MIN.
7" MIN.
8 3/8"
7/8"∅
9"
CAST IN PLACE
3"
1 1/2" (MIN)
CONCRETE WALL
LOCKWASHER
FILLET WELD
2 1/2"∅ WASHER
6 1/2" X 2 1/2" X 3/16" PLATE
ALTERNATE METHOD
CL
2 1/2" RAD
1"∅ U-BOLT
1"∅ NUT
1 1/4"∅ SLEEVE
13/16"
3/16" 4"
NOTE:
ALL METAL PARTS SHALL
BE HOT DIP GALVANIZED
45°
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :0
A
M
TS502
TE
LE
C O
M M
U N
IC
A
TI
O
N S
S
IT
E D
E
TA
IL
S
SMW
12801887
WJS EAK
1596300
NOT TO SCALE
A1
STANDARD ELECTRICAL MANHOLE (NONTRAFFIC)
NOT TO SCALE
A3
STANDARD ELECTRICAL MANHOLE (TRAFFIC)
NOT TO SCALE
C1
STANDARD ELECTRICAL MANHOLE (AIRFIELD)
NOT TO SCALE
C3
STANDARD ELECTRICAL HANDHOLE (TRAFFIC/AIRFIELD)
NOT TO SCALE
A4
STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC)
(COMPOSITE/FIBERGLASS)
NOT TO SCALE
C4
DETAILS (PULLING-IN IRONS,
CABLE RACK AND DUCT ENTRANCE)
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
RGS
24"X36"X12" STAINLESS STEEL NEMA 4X WITH FULL
LENGTH HINGE, FOAM GASKET AND PROVISIONS FOR
PADLOCKING. PROVIDE WITH 19" MOUNTING BRACKET,
FIBER AND COPPER PATCH PANELS REQUIRED FOR
CABLING TO BE INSTALLED.
SEE DETAIL 9 ON SHEET S621 FOR
C-CHANNEL ANCHORAGE INFORMATION.
3'
6"
C E
N T
E R
O R
E Q
U
IP
M E
N T
ENCASE CHANNEL IN 18"
DIAMETER X 3'-0" DEEP
CONCRETE PIER
GALV RIGID STEEL COUPLING
(TYP)
PVC COATED RGS ELBOW (TYP)
C4X5.4 CHANNELS,
TYPICAL
M
IN
3" 3" 3"
NOTES:
1. USE PLASTIC CONDUIT SPACERS AT 5'-0" OC.
3000 PSI CONCRETE
10 11
FABRIC INNERDUCT
7 8
TOP OF PAVEMENT SUBGRADE OR GRADE
SELECT BACKFILL
WARNING TAPE,
6" BELOW GRADE
4" SCHEDULE 40
PVC CONDUIT
3"
4 5 6
1 2 3
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :0
A
M
TS503
TE
LE
C O
M M
U N
IC
A
TI
O
N S
S
IT
E D
E
TA
IL
S
SMW
12801888
WJS EAK
1596300
NOT TO SCALE
A3
ELECTRICAL EQUIPMENT C-CHANNEL SUPPORT STRUCTURE
NOT TO SCALE
A1
TYPICAL 4 X 3 CONCRETE ENCASED DUCTBANK
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
ATCT
COMM
RM
COMM
RM
COMM
RM
MTRACON
BASE NODE
VAULT
COMM
RM
BASE NODE
RM 155
AIRFIELD
LIGHTING
RM 108
COMM
RM
RM 120
ASOS
AIR OPS
BLDG
MH-012
MH-A29
MH-013
MH-C02
MH-C06
MH-C04
MH-014
MH-015
BLDG
R-NX1
2 2
3 3
3 2
4 4
R-21
1 1
R-30
R-34
R-30A R-30B R-30C R-30D R-30E
R-34A R-34B R-34C
1 TYP
TYP
ATCM
ATCM
CABLE LEGEND
MANHOLE
EXISTING CABLE
NEW CABLE
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :0
A
M
TS701
O U
TS
ID
E P
LA
N
T C
A B
LI
N
G L
O G
IC
A
L D
IA
G
R A
M
SMW
12801889
WJS EAK
1596300
NOT TO SCALE
A1
TELECOMMUNICATIONS OSP CONDUIT LOGICAL DIAGRAM
WORK NOTES
GENERAL NOTES
1. REFER TO T-001 FOR TELECOMMUNICATIONS GENERAL NOTES, SYMBOL
LEGEND, AND ABBREVIATIONS.
2. REFER TO T-002 AND T-003 FOR EQUIPMENT LABELING INFORMATION.
3. REFER TO TELECOM SITE DRAWINGS (TS100 SERIES) FOR PHYSICAL
ROUTING OF CONDUIT DUCTBANKS AND ASSOCIATED CABLING.
4. PRIOR TO INSTALLATION OF NEW CABLE IN EXISTING DUCTBANKS, THE
CONTRACTOR SHALL COORDINATE WITH THE COR TO DETERMINE WHICH
DUCT(S) SHALL BE USED.
1. PROVIDE NEW CONDUIT DUCTBANK, REFER TO SITE PLANS FOR
ADDITIONAL INFORMATION.
2. PROVIDE EXISTING CONDUIT DUCTBANK PROVIDED UNDER P-235
PROJECT, REFER TO SITE PLANS FOR ADDITIONAL INFORMATION.
3. PROVIDE EXISTING CONDUIT DUCTBANK, REFER TO SITE PLANS FOR
ADDITIONAL INFORMATION.
4. PROVIDE NEW INTRA BUILDING CONDUITS, REFER TO TC101 AND TC102
FOR ADDITIONAL INFORMATION.
5. PROVIDE NEW INTRA BUILDING CONDUITS, REFER TO TC111 AND TC121
FOR ADDITIONAL INFORMATION.
6. PROVIDE (1) 4" CONDUIT FROM THE NEAREST HANDHOLE TO BUILDING.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
FPP
MTRACON
FPP
FPP
FPP
BASE NODE
VAULT
BASE NODE
AIR OPS
MH-012
MH-A29
MH-013
MH-C02
MH-C06
MH-C04
MH-014
MH-015
MH-R21
FPP
FPP
RM 108
FPP
RM 212
BLDG
BIRD
RADAR
PAR
ILS
MH-34CMH-R34
MH-R30
MH-R30B
BLDG
OSP-06
OSP-04
OSP-05
OSP-01
OSP-02
OSP-03
ISP-05
ISP-06
ISP-07
ISP-10
ISP-15
OSP-10
OSP-09
OSP-08
OSP-11
OSP-07
OSP-19 OSP-21
OSP-18
OSP-20
OSP-12
OSP-14
OSP-16
OSP-17
OSP-13
OSP-15
ISP-14
FPP
ISP-09
ISP-08
ISP-13
ISP-01
ISP-02
ISP-03
ISP-04
OSP-01
ISP-11 ISP-12
RM 155
4 TYP
TYP
RM 120
NBC
Rx
RADAR
ASR
TACAND
Tx
HIGH POWER
GLIDE SCOPE
ILS
RM 119
ISP-16
CABLE LEGEND
CABLE SPLICE
FIBER PATCH PANEL, REFER TO TN200 SERIES DRAWINGS.
EXISTING CABLE
NEW CABLE
FUTURE CABLE
FPP
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
W E
R A
N D
A
IR
O P
E R
A T
IO
N
S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
F
IL
E N
A M
E
P
LO
T T
E D
CJC/KDB
JAS
DSN
C
U s e rs
\a b s a n to s \O n e D ri v e
B u rn s
M c D o n n e ll\
D o c u m e n ts
\B L D
G -P
-1
-T
-O P
S -C e n tr a l_ a b a lle n Y
H
C
.r v t
/1
/2
:1 :1
A
M
TS702
TE
LE
C O
M M
U N
IC
A
TI
O
N S
O S
P F
IB
E
R L
O G
IC
A
L D
IA
G
R A
M
SMW
12801890
WJS EAK
1596300
NOT TO SCALE
A1
TELECOMMUNICATIONS OSP FIBER LOGICAL DIAGRAM
WORK NOTES
GENERAL NOTES
1. PROVIDE WALL MOUNTED FIBER ENCLOSURE WITH SPLICE TRAY AND FIBER
CONNECTOR HOUSINGS WITH LC CONNECTORS. REFER TO PLANS FOR
LOCATION. TERMINATE ISP CABLE NOTED.
2. PROVIDE WALL MOUNTED SPLICE ENCLOSURE, SPLICE OSP CABLE TO ISP
CABLE AS NOTED.
3. PROVIDE VAULT SPLICE ENCLOSURE, SPLICE OSP CABLE TO ISP CABLE
NOTED. REFER TO TN404 FOR ADDITIONAL INFORMATION.
4. PROVIDE VAULT SPLICE ENCLOSURE.
5. PROVIDE WALL MOUNTED FIBER ENCLOSURE WITH SPLICE TRAY AND FIBER
CONNECTOR HOUSINGS (FCH) WITH LC CONNECTORS. REFER TO PLANS FOR
LOCATION. TERMINATE ISP CABLE NOTED AND LABEL AS FOLLOWS:
• FCH-01: GLIDE SCOPE, ILS
• FCH-02: Tx, BUILDING 1776
• FCH-03: ASR, BUILDING 4150
• FCH-04: RADAR, BUILDING 4853
• FCH-05: Rx, BUILDING 1695
• FCH-06: PAR
• FCH-07: ILS, BUILDING 4632
1. REFER TO T-001 FOR TELECOMMUNICATIONS GENERAL NOTES, SYMBOL
LEGEND, AND ABBREVIATIONS.
2. REFER TO T-002 AND T-003 FOR EQUIPMENT LABELING INFORMATION.
3. REFER TO TELECOM SITE DRAWINGS (TS100 SERIES) FOR PHYSICAL
ROUTING OF CONDUIT DUCTBANKS AND ASSOCIATED CABLING.
4. PRIOR TO INSTALLATION OF NEW CABLE IN EXISTING DUCTBANKS, THE
CONTRACTOR SHALL COORDINATE WITH THE COR TO DETERMINE WHICH
DUCT(S) SHALL BE USED.
5. PRIOR TO SPLICING TO EXISTING FIBER OPTIC CABLES, THE CONTRACTOR
SHALL COORDINATE WITH THE COR TO DETERMINE FIBER CABLE AND FIBER
STRANDS TO SPLICE.
6. ALL CABLE SPLICE ENCLOSURES SHALL BE CONTRACTOR PROVIDED.
7. ALL NEW DARK COPPER AND FIBER CABLE SPLICING SHALL BE PROVIDED
AND PERFORMED BY THE CONTRACTOR.
8. ALL NEW COPPER AND FIBER CABLE SPLICING TO EXISTING BASE FIBER
AND COPPER CABLE PLANT SHALL BE PROVIDED AND PERFORMED BY THE
GOVERNMENT.
ISP-FOC 16 AIR OPS 156 AIR OPS 119 NMCI/MCEN SIPR 6 SINGLE MODE (OS2) - PLENUM, ARMORED WX, SECURE USER DROP BOX.
ISP-FOC 15 MTR 150 ATCT 2704 ATC 24 SINGLE MODE (OS2) - PLENUM
ISP-FOC 14 MTR 105 MTR 150 ATC 12 SINGLE MODE (OS2) - PLENUM
ISP-FOC 13 MTR 105 MTR 121 ATC 144 SINGLE MODE (OS2) - PLENUM SPLICE OSP FOC #01
ISP-FOC 12 AIR OPS 108 AIR OPS 120 ATC 12 SINGLE MODE (OS2) - PLENUM
ISP-FOC 11 AIR OPS 108 AIR OPS 155 ATC 12 SINGLE MODE (OS2) - PLENUM AIR FIELD LIGHTING
ISP-FOC 10 ATCT 2109 ATCT 2704 ATC 48 SINGLE MODE (OS2) - PLENUM
ISP-FOC 09 MTR 121 ATCT 2704 ATC 24 SINGLE MODE (OS2) - PLENUM
ISP-FOC 08 MTR 105 MTR 121 ATC 48 SINGLE MODE (OS2) - PLENUM
ISP-FOC 07 MTR 105 ATCT 2109 ATC 48 SINGLE MODE (OS2) - PLENUM
ISP-FOC 06 AIR OPS 108 AIR OPS 212 NMCI/MCEN 48 SINGLE MODE (OS2) - PLENUM
ISP-FOC 05 AIR OPS 156 AIR OPS 108 NMCI/MCEN/ATC 48 SINGLE MODE (OS2) - PLENUM
ISP-FOC 04 AIR OPS BN VAULT AIR OPS 156 DATA-PRIMARY 48 SINGLE MODE (OS2) - PLENUM SPLICE OSP FOC #05
ISP-FOC 03 AIR OPS BN VAULT AIR OPS 156 DATA-SECONDARY 24 SINGLE MODE (OS2) - PLENUM SPLICE OSP FOC #04
ISP-FOC 02 AIR OPS BN VAULT AIR OPS 156 ATC 144 SINGLE MODE (OS2) - PLENUM SPLICE OSP FOC #01
ISP-FOC 01 AIR OPS BN VAULT AIR OPS 156 ATC 144 SINGLE MODE (OS2) - PLENUM SPLICE OSP FOC #06
CABLE ID CABLE LABEL FROM BLDG/SITE ROOM / VAULT TO BLDG/SITE ROOM / VAULT NETWORK STR/PR QNTY CABLE TYPE NOTES
P-228 ACT TOWER & AIR OPERATIONS: INSIDE PLANT FIBER OPTIC CABLING SCHEDULE
OSP-FOC 21 SITE MH-34C 1776 ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #19: 13-24
OSP-FOC 20 SITE MH-34C 4041 ATC 12 FUTURE OUTDOOR SINGLE MODE (OS2) SPLICE OSP #19: 1-12, PROVIDE SPLICE ENCLOSURE FOR FUTURE SPLICE BY CHERRY POINT TISD.
OSP-FOC 19 SITE MH-R34 MH-34C ATC 24 OUTDOOR SINGLE MODE (OS2) - (2) 12STR FIBER GROUPS SPLICE OSP #11: 13-36
OSP-FOC 18 SITE MH-R34 4633 ATC 12 FUTURE OUTDOOR SINGLE MODE (OS2) SPLICE OSP #11: 1-12, PROVIDE SPLICE ENCLOSURE FOR FUTURE SPLICE BY CHERRY POINT TISD.
OSP-FOC 17 SITE MH-R30B 1695 ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #14: 25-36
OSP-FOC 16 SITE MH-R30B 4853 ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #14: 13-24
OSP-FOC 15 SITE MH-R30B 4150 ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #14: 1-12
OSP-FOC 14 SITE MH-R30 SITE MH-R30B ATC 36 OUTDOOR SINGLE MODE (OS2) - (3) 12STR FIBER GROUPS SPLICE OSP #07: 61-96
OSP-FOC 13 SITE MH-R30 1660 ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #07: 49-60
OSP-FOC 12 SITE MH-R30 BIRD RDR ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #07: 37-48
OSP-FOC 11 SITE MH-R30 SITE MH-R34 ATC 36 OUTDOOR SINGLE MODE (OS2) - (3) 12STR FIBER GROUPS SPLICE OSP #07: 1-36
OSP-FOC 10 SITE MH-R21 ILS ATC 12 FUTURE OUTDOOR SINGLE MODE (OS2) SPLICE OSP #06: 133-144, PROVIDE SPLICE ENCLOSURE FOR FUTURE SPLICE BY CHERRY POINT TISD.
OSP-FOC 09 SITE MH-R21 PAR ATC 12 OUTDOOR SINGLE MODE (OS2) SPLICE OSP #06: 121-132
OSP-FOC 08 SITE MH-R21 4081 ATC 24 EXISTING OUTDOOR SINGLE MODE (OS2) SPLICE OSP #06: 97-120, CABLE SPLICING SHALL BE PROVIDED BY CHERRY POINT TISD.
OSP-FOC 07 SITE MH-R21 SITE MH-R30 ATC 144 OUTDOOR SINGLE MODE (OS2) - (12) 12STR FIBER GROUPS SPLICE OSP #06: 1-96
OSP-FOC 06 AIR OPS BN VAULT SITE MH-R21 ATC 144 OUTDOOR SINGLE MODE (OS2) - (12) 12STR FIBER GROUPS
OSP-FOC 05 4397 MH-014 AIR OPS BN VAULT PRIMARY 48 OUTDOOR SINGLE MODE (OS2) SPLICE TO EXISTING 4397 FOC IN MH-014, CABLE SPLICING SHALL BE PROVIDED BY CHERRY POINT TISD.
OSP-FOC 04 4851 MH-014 AIR OPS BN VAULT SECONDARY 24 OUTDOOR SINGLE MODE (OS2) SPLICE TO EXISTING 4851 FOC IN MH-014, CABLE SPLICING SHALL BE PROVIDED BY CHERRY POINT TISD.
OSP-FOC 03 4397 MH-C06 ATCT 2109 NMCI/MCEN 48 OUTDOOR SINGLE MODE (OS2) SPLICE TO EXISTING 4397 FOC IN MH-C06, CABLE SPLICING SHALL BE PROVIDED BY CHERRY POINT TISD.
OSP-FOC 02 4397 MH-013 MTR 105 NMCI/MCEN 48 OUTDOOR SINGLE MODE (OS2) SPLICE TO EXISTING 4397 FOC IN MH-013, CABLE SPLICING SHALL BE PROVIDED BY CHERRY POINT TISD.
OSP-FOC 01 MTR 121 AIR OPS BN VAULT ATC 144 OUTDOOR SINGLE MODE (OS2)
CABLE ID CABLE LABEL FROM BLDG/SITE ROOM / VAULT TO BLDG/SITE ROOM / VAULT NETWORK STR/PR QNTY CABLE TYPE NOTES
P-228 ACT TOWER & AIR OPERATIONS: OUTSIDE PLANT FIBER OPTIC CABLING SCHEDULE
6. PROVIDE 24"X24"X10" WALL MOUNTED EQUIPMENT CABINET, COMBINE WITH
OSP CU, REFER TO TS703. PROVIDE FIBER OPTIC FAN OUT KIT AND CRIMP-ON
PRE-POLISHED LC CONNECTORS. COORDINATE WITH COR ON CABINET
LOCATION WITHIN BUILDING.
7. PROVIDE EXTERIOR 24"X24"X10" EQUIPMENT CABINET. PROVIDE FIBER OPTIC
FAN OUT KIT AND CRIMP-ON PRE-POLISHED LC CONNECTORS. COORDINATE
WITH COR ON CABINET LOCATION ON STRUCTURE. REFER TO DETAIL
A3/TS503 FOR ADDITIONAL REQUIREMENTS.
8. PROVIDE WALL MOUNTED FIBER ENCLOSURE WITH SPLICE TRAY AND FIBER
CONNECTOR HOUSINGS (FCH) WITH LC CONNECTORS. REFER TO PLANS FOR
LOCATION.
13-24 OSP #21 12
01-12 OSP #20 12
STRANDS SPLICE CABLE ID STR. COUNT
CABLE ID OSP #19
CABLE SPLICE SCHEDULE
25-36 OSP #17 12
13-24 OSP #16 12
01-12 OSP #15 12
STRANDS SPLICE CABLE ID STR. COUNT
CABLE ID OSP #14
CABLE SPLICE SCHEDULE
13-36 OSP #19 24
01-12 OSP #18 12
STRANDS SPLICE CABLE ID STR. COUNT
CABLE ID OSP #11
CABLE SPLICE SCHEDULE
96-144 Unavailable
61-96 OSP #14 36
49-60 OSP #13 12
37-48 OSP #12 12
01-36 OSP #11 36
STRANDS SPLICE CABLE ID STR. COUNT
CABLE ID OSP #07
CABLE SPLICE SCHEDULE
133-144 OSP #10 12
121-132 OSP #09 12
97-120 OSP #08 24
01-96 OSP #07 96
STRANDS SPLICE CABLE ID STR. COUNT
CABLE ID OSP #06
CABLE SPLICE SCHEDULE
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R B
ID
/1 8/
CTB
MTRACON
BET
CTB
BET
BASE NODE
VAULT
BASE NODE
AIR OPS
MH-012
MH-A29
MH-013
MH-C02
MH-C06
MH-C04
MH-014
MH-015
MH-R21
BET
CTB
RM 108
CTB
RM 212
BLDG
BIRD
RADAR
PAR
MH-34C
MH-
R34
MH-
R30A
MH-
R30B
MH-
R30
MH-
R23
MH-
R22
BLDG
OSP-05
OSP-03
OSP-04
OSP-01
ISP-04
ISP-05
ISP-02
ISP-03
ISP-01
ISP-06
ISP-11
OSP-17
OSP-11
OSP-18 OSP-20
OSP-21
OSP-19
OSP-13
OSP-15
OSP-16
OSP-12
OSP-14
OSP-02
OSP-07
OSP-06
OSP-10
OSP-08
OSP-09
3 TYP
CTB
ISP-08
ISP-07
ISP-12
RM 155 RM 120
GLIDE SCOPE
ILS
HIGH POWER
Tx
TACAND
ASR
RADAR
Rx
NBC
ILS
CTB
CTB
CTB
7 7
OSP-22
CTBCTB
ISP-10
ISP-09
1 CABLE LEGEND
CABLE SPLICE
COPPER TERMINATION BLOCK
EXISTING CABLE
NEW CABLE
FUTURE CABLE
CTB
BUILDING ENTRANCE TERMINALBET
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
M
A R
IN
E
C O
R P
S I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y
P
-2 A
T C
T O
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .