7'-6"
X X X X X X X X X X X X X X X X X X X X X X
ATTACK SIDE
PROTECTED SIDE
1.2 5'
0.2 1'
TY
PI
CA
L
INSTALL WELDED BRACE RAILS AS PER THE PLANS
AND AWS D1.1 (STRUCTURAL WELDING CODE - STEEL)
AT CORNER, END, GATE, AND PULL POSTS. REPAIR
DAMAGE TO THE GALVANIZED SURFACE, DUE TO
WELDING, WITH "REPAIR STICKS" OF ZINC-CADMIUM
ALLOYS OR ZINC-TIN LEAD ALLOYS AS PER AWS WZC.
3' - 0"2' - 0"
5.00'
TYPICAL POST SPACING UON
1'- 0"
OFFSET CONCRETE BLOCK OF DEADMAN SYSTEM A
MINIMUM DISTANCE AND ANGLE TO AVOID CONFLICT
WITH LINE POST FOUNDATION (TYP). CONCRETE
DEADMAN & POST OR BOLLARD FOUNDATION CAN BE
PLACED MONOLITHICALLY. MAX ANGLE 45 DEGREES.
ANCHOR POST LINE POST
PROVIDE CABLE ON ATTACK SIDE OF ALL POSTS AND FENCE UONBOLLARDS
END OF LINE POST
PULL POST (CORNER POST, END POST, OR LAST
LINE POST TO RECEIVE CABLE REINFORCING)
PROVIDE 3 4" Ø GALV STRUCTURAL
WIRE ROPE PER NOTE 1 (TYP)
ANCHOR POST LINE POST
FENCE FABRIC NOT
SHOWN FOR CLARITY
PROVIDE 1 1/4" Ø SCHED
40 PIPE BRACE RAILS
WELD TO POSTS, TYP
PROVIDE 1.25" Ø x 6'-0"± LONG, RIGHT-HAND
THREADED ROD (GALV). SEE DETAIL B3/CS513
TYPICAL DEADMAN. SEE DETAIL A1/CS512
PROVIDE MIN 18" TURNBACK.
SEE DETAIL B1/CS513
BOLLARDS (PER DETAIL
A2/CS504) MAY BE PLACED AT
END OF CABLE REINFORCING TO
PROTECT SECTIONS OF FENCE
THAT ARE NOT HARDENED.
FOR FOOTING DETAIL, SEE A1/CS512
REINFORCING NOTES:
1. REINFORCING CABLES MUST BE U.S. DOMESTIC MINIMUM 3/4" Ø 6x19
CLASS WIRE ROPE, REGULAR LAY, EXTRA IMPROVED PLOW STEEL (EIP),
INDEPENDENT WIRE ROPE CORE (IWRC), CONFORMING TO ASTM A1023
AND GALVANIZED IN ACCORDANCE WITH ASTM A475 CLASS A, & HAVE A
MINIMUM BREAKING STRENGTH OF 40,000 POUNDS (20 TONS). CABLES
WITH A BLACK VINYL COATING, MUST NOT BE IMPREGNATED.
2. CABLES MUST BE CONTINUOUS FROM DEADMAN TO DEADMAN. SPLICES
IN CABLE ARE NOT ALLOWED. INSTALL CABLE BARRIER BETWEEN FENCE
POST AND FENCE FABRIC AS PER PLANS. INSTALL U-BOLTS
PERPENDICULAR TO THE LAY OF THE STRANDS OF THE WIRE ROPE AND
TIGHTEN AFTER SAG IN CABLE BARRIER HAS BEEN REMOVED. UNLESS
INDICATED OTHERWISE, CONCRETE DEADMAN SPACING MUST BE AT
MAXIMUM 200' INTERVALS & TURNING POINTS (EXTERNAL CORNERS).
3. WIRE ROPE ENDS MUST TERMINATE AROUND TURNBUCKLES, GATE
POSTS OR EXTRA HEAVY-DUTY WIRE ROPE THIMBLES (AT GATES).
THESE TERMINATIONS REQUIRE 18" MINIMUM OF ROPE FOR TURN BACK
AND A MINIMUM OF (4)- CLIPS EACH (EQUAL SPACING).
4. FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING MATERIALS.
5. INSTALL DEADMEN ON THE SECURED SIDE (INTERIOR) OF THE FENCE;
INSTALL CABLES ON THE EXTERIOR SIDE OF POST.
6. OFFSET DEADMAN SYSTEMS FROM FENCELINE (PLAN VIEW) TO AVOID
CONFLICT WITH EXISTING FENCE POSTS.
7. ALLOW EPOXY ANCHOR BOLTS (MIN 2 DAYS) & CONCRETE DEADMEN (MIN
7 DAYS) TO CURE, PRIOR TO APPLYING LOADS (INSTALLING
TURNBUCKLES & STRAIGHTENING CABLES).
8. ALL WELDING MUST BE DONE IN ACCORDANCE WITH AWS D1.1. ALL
WELD MATERIAL MUST BE E70XX ELECTRODES.
9. STRUCTURAL STEEL CONSTRUCTION MUST BE IN ACCORDANCE WITH
THE NINTH EDITION OF THE AISC "MANUAL OF STEEL CONSTRUCTION
FOR ALLOWABLE STRESS DESIGN.
10. STRUCTURAL STEEL MUST CONFORM TO ASTM A36 AND MUST HAVE A
MINIMUM YIELD STRESS OF 36,000 PSI.
11. ALL STRUCTURAL STEEL MEMBERS AND HARDWARE USED IN CABLE
ANCHORING SYSTEM MUST BE HOT-DIPPED GALVANIZED. COVER ANY
AREAS WHERE COATING IS DAMAGED OR REMOVED WITH A ZINC RICH
COMPOUND.
12. TURNBUCKLES MUST BE 114"x18", TYPE I, GALVANIZED IN ACCORDANCE
WITH ASTM F1145.
13. WIRE ROPE CLAMPS MUST BE TYPE I, GALVANIZED, AND CONFORM TO FS
FF-C-450.
14. ALL THREADED RODS, U-BOLTS, AND BOLTS MUST CONFORM TO ASTM
A307 AND MUST BE INSTALLED WITH F844 WASHERS AND A563 NUTS.
GALVANIZE ENTIRE BOLT ASSEMBLY IN ACCORDANCE WITH ASTM A153.
INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
15. ZINC RICH COMPOUND FOR REPAIRS MUST BE 95% METALLIC ZINC, BY
WEIGHT IN DRIED FILM; INSTALL AT LEAST TWO COATS, 4 MILS MIN
TOTAL THICKNESS.
16. ALL CONCRETE WORK MUST BE IN ACCORDANCE WITH THE LATEST
EDITION OF ACI 318. CONCRETE MUST HAVE A MINIMUM 28-DAY
COMPRESSIVE STRENGTH OF 4000 PSI. THE MINIMUM CONCRETE COVER
MUST BE 3", UNLESS OTHERWISE NOTED.
17. DESIGN CRITERIA:
UFC 4-022-03 "SECURITY ENGINEERING: FENCES, GATES AND GUARD
FACILITIES"
UFC 4-022-02 "SELECTION AND APPLICATION OF VEHICLE BARRIERS"
C1 TYPICAL PLAN OF END POST DEADMAN AND LINE POST LAYOUT
NTS
A1 TYPICAL ELEVATION OF END POST DEADMAN AND LINE POST LAYOUT
NTS
CS511
A1
C4
CS513
C4
CS513 C1
CS513
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
IS
SU
ED
F
OR
B
ID
/18
/22
CS511
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
PR
OFESS I ONAL
ENG I N E E R
NO
RTH CAROL I NA
CASS NDRA L Z WART
SEAL
049323
A 08/18/22
0.2 1'
1.2 5'
3.75'± 3.75'±
7'-6" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
7'-6"
OFFSET CONCRETE BLOCK OF DEADMAN SYSTEM
A MINIMUM DISTANCE AND ANGLE TO AVOID
CONFLICT WITH LINE POST FOUNDATION (TYP).
CONCRETE DEADMAN & POST FOUNDATION CAN
BE PLACED MONOLITHICALLY.
[ATTACK SIDE]
[PROTECTED SIDE]
0.7 5'
1.16'
0.2 1'
10'-0"
TYPICAL POST SPACING UON
0.2 5'
1.5 0'
3'- 0" x x x x x x x x x x x x x x x x x x x x x x
'A' CABLE 'B' CABLE
'B' CABLE
'A' CABLE
[PROTECTED SIDE]
[A
TT
AC
K
SI
DE
[ATTACK SIDE]
(INTERNAL CORNER SHOWN)
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
DEADMAN 'B'
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
[PROTECTED SIDE]
[ATTACK SIDE]
(EXTERNAL CORNER SHOWN)
DEADMAN 'A'
PROTECTED SIDE
45°
MAX
TY
P
1.6 7'
TY
P
1.6 7'
TY
P
1'-0"
45°
TYP
CONCRETE DEADMAN "B"
PROVIDE CABLE ON ATTACK SIDE OF ALL POSTS AND FENCE UON.
CONCRETE DEADMAN "A"
DOUBLE SIZED DEADMAN ANCHOR
BOLLARD, TYP
FENCE FABRIC
PROVIDE 3/4" Ø GALV. STRUCTURAL
WIRE ROPE (TYP CABLE REINF UON)
"A" CABLES
PROVIDE GALV LEFT-HAND THREADED
TURNBUCKLE EYE END (FOR 1 1/4" Ø x 18" TAKE-UP)
PROVIDE 1.25" TURN- BUCKLE
BODY WITH 18" TAKE-UP (GALV)
PROVIDE 1.25" Ø x 6'-0"± LONG, RIGHT-HAND
THREADED ROD (GALV) SEE DETAIL B3/CS513
PROVIDE TYPICAL
3'-0" x 3'-0" x 1'-6"
CONC DEADMAN
CONCRETE DEADMAN "B"
PROVIDE 1 1/4" Ø SCHED 40 PIPE
BRACE. WELD TO POSTS (TYP) PROVIDE 1 1/4" Ø SCHED 40 PIPE
BRACE. WELD TO POSTS (TYP)
FOOTING DIA MUST BE 4
TIMES THE WIDTH OF THE
POST. EMBED POST 36" INTO
42" DEEP FOOTING.
PULL POST
ANCHOR POST (OR CORNER POST)
PULL POSTFENCE FABRIC NOT
SHOWN FOR CLARITY
1/2" Ø TRUSS ROD ASSEMBLIES.
INSTALL PER MANUFATURER'S
RECOMMENDATIONS.
LINE POST
PROVIDE MIN. 18" TURNBACK.
SECURE W/ (4)-WIRE ROPE CLIPS
(TYP). SEE DET B1/CS513
"B" CABLES TY
P
CONCRETE DEADMAN "A"
DEADMAN SHOWN FOR ILLUSTRATION ONLY.
ACTUAL DEADMAN LOCATION AS PER SPACING
REQUIREMENTS DETAILED IN REINF NOTE 2 ON
SHEET CS511 (TYP).
PULL POST, DEADMAN "A"
"B" CABLE
ANCHOR POST
PULL POST, DEADMAN "B"
CABLE "A"
C1 TYPICAL PLAN OF DEADMAN AND LINE POST LAYOUT
NTS
A1 TYPICAL ELEVATION OF DEADMAN AND LINE POST LAYOUT
NTS
CS512
A1
C4 TYPICAL PLAN OF TURNING POINT POST LAYOUT
NTS
A4 TYPICAL PLAN OF TURNING POINT POST LAYOUT
NTS
C2
CS513 C2
CS513
C1
CS513
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
IS
SU
ED
F
OR
B
ID
CS512
DON ELLIOT 12/19/19
PR
OFESS I ONAL
ENG I N E E R
NO
RTH CAROL I NA
CASS NDRA L Z WART
SEAL
049323
0.25' 1.00' 1.50'
6'-0" TO 8'-0"
3/16"
1/4"x4"x0'-4" PL (W/ 1 5/16" DIA IN CENTER FOR ROD)
* 5 1 4" or 6 1 4"
11 2"
* FIELD VERIFY.
6 14" FOR 4"Ø POSTS
THREADED REGION
(* OUTSIDE OF CABLE IF INSTALLING
NEW FENCE; INSIDE OF CABLE IF
RETROFITTING EXIST CLF)
TO DEADMAN
GROUND LEVEL
0.6 3'
3/
4"
(7 ) S
PA
CE
S
11 4"
83 4" 11 4"
2.8 1'
11 4"
0.6 3'
0.6 3'
ADJUST CABLE
HEIGHTS AS
INDICATED WHERE
CABLES OVERLAP
SECTION B - B
1.25'
(TYP.)
18" MINIMUM TURN BACK
0.75'
(MIN.)
TO DEADMAN
GROUND LEVEL
11 4" 11 4"
3 3 4"
NOTE: INSTALL SADDLE OF CLIPS ON LIVE SIDE (AS SHOWN), SEIZE CUT
END OF WIRE ROPE, AND TORQUE NUTS PER MANUFACTURER'S
RECOMMENDATIONS (TYP).
STANDARD NUT AND LOCK WASHER
LINE POST
U-BOLT
3/4" Ø WIRE ROPE
CHAIN-LINK FABRIC 4" NOMINAL Ø POST (TYP)
"A" CABLES
CONTINUOUS CABLE
@ ANCHOR POST
"B" CABLES
PROVIDE 3/4" Ø
STRUCTURAL WIRE
ROPE (TYPICAL)
3/8" FLAT BAR, 1 1/2" WIDE;
PROVIDE HOLES AS
REQUIRED TO RECEIVE
U-BOLTS
STRIP EXPOSED THREADS AFTER TIGHTENING
NUT OR TACK WELD (TYP EVERY 4TH POST)
PROVIDE 1/2" Ø STEEL U-BOLT W/
PL (TYP OF 4 @ EACH POST). SEE
DETAIL A1 THIS SHEET
"A" CABLES
"B" CABLES
PROVIDE LOCK WASHER
AND HEX NUT, TYP
PROVIDE 3/4" Ø GALV
STRUCTURAL WIRE ROPE
4" NOMINAL Ø POST (TYP)
CONT CABLE @
ANCHOR POST OR
STANDARD LINE POST
PROVIDE LOCK WASHER
AND HEX NUT, TYP
PROVIDE 1/2" Ø STEEL
U-BOLT W/ PL (TYP OF 2
@ EACH POST). SEE
DETAIL A1 THIS SHEET
3/8" FLAT BAR, 1 1/2" WIDE;
PROVIDE HOLES AS REQUIRED
TO RECEIVE U-BOLTS
STRIP EXPOSED THREADS
AFTER TIGHTENING OR TACK
WELD (TYP EVERY 4TH POST)
INSTALL U-BOLT
PERPENDICULAR TO STRANDS
OF WIRE ROPE (TYP)
LINE POST
3/4" Ø WIRE ROPE
WIND SEIZING WIRE IN A TIGHT SPIRAL AROUND THE
ROPE END TO A 1" LENGTH OF SEIZING. TWIST THE
TWO ENDS OF THE SEIZING WIRE AT THE CENTER OF
THE SEIZING LENGTH. USE ZINC COATED STEEL WIRE.
CABLE CLAMP SEE
DETAIL B2 THIS SHEET
PROVIDE GALV. EXTRA HEAVY-DUTY WIRE ROPE
THIMBLE, EXCEPT WHERE ENCIRCLING
GATE/FENCE POST OR TURNBUCKLE EYE.
PROVIDE GALV WIRE ROPE
CABLE CLAMP (TYPICAL OF
4) W/ LOCK NUTS.
1/2" Ø
1 1/2" DIA GALV STEEL ROD
C1 LINE POST DETAIL
NTS
CS513
A
SECTION A-A
CS513
B
C2 CABLE ANCHORAGE DETAIL @ PULL & ANCHOR POST W/ OVERLAPPING CABLES
NTS C4 CABLE ANCHORAGE DETAIL @ PULL & ANCHOR POST
NTS
SECTION C - C
CS513
C
B1 TYPICAL TURNBACK AND CLAMP DETAIL
NTS B2 CLAMP DETAIL
NTS
A1 FENCE U-BOLT DETAIL
NTS
B3 DEADMAN ANCHOR ROD
NTS
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
IS
SU
ED
F
OR
B
ID
CS513
DON ELLIOT 12/19/19
PR
OFESS I ONAL
ENG I N E E R
NO
RTH CAROL I NA
CASS NDRA L Z WART
SEAL
049323
IMPACT DIRECTION
OUTSIDE
INSIDE
NOTES:
1. K4 RATED MOTORIZED SLIDE GATE MUST BE TYMETAL TCG-4 OR APPROVED EQUAL.
2. PROVIDE CURB KNOCKOUTS AS REQUIRED FOR GATE OPERATION.
3. CONTRACTOR TO SUBMIT SEALED DRAWINGS FOR GATE AND K4 CRASH BEAM
FOUNDATIONS.
TYM-HYD GATE OPERATOR
GATE FRAME
HANGER ASSEMBLY
CATCH ASSEMBLY
4" O.D POST (TYP)
8" SQ. STEEL
STANCHION
BARBED WIRE
BARB ARM
TOP PRIMARY MEMBER
4" O.D
POST (TYP)
CABLE (TYP.)
1" x 2" ALUM. TUBE (TYP.)
8" SQ. STEEL
STANCHION
WITH Z-POST
LEFT to Open
A = CLEAR OPENING
B = POST SPACING C/C
BE
TW
EE
N
PO
ST
S
8'
- 6
7'
- 0
5"
G
RA
DE
CL
EA
RA
NC
E
VARIES
2" x 2" ALUM. TUBE (TYP.)
K4 CRASH BEAM
2" x 5" ALUM. TUBE
FABRIC (AS REQUIRED)
CATCH ASSEMBLY
DRIVE RAIL
FINISHED
ROAD GRADE
GATE OPERATOR
BOTTOM GUIDE ASSEMBLY
HANGAR ASSEMBLY
B1 K4 RATED MOTORIZED SLIDE GATE
NTS
ELEVATION
PLAN
-OUTSIDE-
-INSIDE-
GATE HANGER ASSEMBLY
STANDARD TRACK
4" O.D. POST
TOP PRIMARY MEMBER
2" x 5" ALUM. TUBE
BOTTOM GUIDE ASSEMBLY
2" x 2" ALUM. TUBE 1" x 2" ALUM. TUBE
(BEHIND)
8" SQ. STEEL
STANCHION WITH
Z-POST
BARB ARM
TYM-HYD OPERATOR
-FINISHED ROAD GRADE-
K4 CRASH BEAM
C4 ASSEMBLY SECTION
NTS
CS514
C4
34" REF.
"D
8" M
IN
12" (MIN)
"D "/2"T"
"T"/2
3" (M
IN
1. REPLACE EXISTING FRAME AND COVER WITH NEW FRAME AND COVER IF EXISTING FRAME AND
COVER IS NOT SALVAGEABLE
2. PRECAST GRADE RINGS MUST NOT EXCEED 2 MAXIMUM FOR A TOTAL MAXUMUM HEIGHT OF 12".
3. PLACE NON-SHRINK GROUT BETWEEN GRADE RINGS FOR ADJUSTMENTS.
4. DEPTH, WIDTH, AND THICKNESS OF NON-SHRINK GROUT MUST BE OF SUFFICENT DIMENSIONS TO PROPERLY JOIN AND SECURE THE COMPONENTS, BUT MUST NOT EXCEED 1" IN ANY DIRECTION.
(6" MIN)
PROPOSED
FINISH GRADE
REUSE EXISTING MANHOLE
RING AND COVER
TYPICAL EXISTING VERTICAL
RISER SECTION
NON-SHRINK GROUT
RECAST REINFORCED
CONCRETE GRADE RINGS
#4 BAR
REINFORCEMENT
CONCRETE POURED
AROUND STRUCTURE
ADJUSTMENT
NOTES:
A4 MANHOLE ADJUSTMENT
NTS
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
IS
SU
ED
F
OR
B
ID
CS514
DON ELLIOT 12/19/19
PR
OFESS I ONAL
ENG I N E E R
NO
RTH CAROL I NA
CASS NDRA L Z WART
SEAL
049323
6"
1'-0"
2'-8"
4'-
2"-8"
4'-
6'-
9 1 /8"
R
EF
9'-
0" T
YP
0.6 1'
ST
AN
CH
IO
N
TO
IN
SI
DE
OF
PO
ST
B - 3'-8" 5'-4"
3'-
1/ 2"
A = CLEAR OPENING
5'- 0"
4'-
" 1'-
5'- 0"
2'- 0"
3'- 2"
(H
OL
D)
1'-2"
6'-0" TYP.
CL OF ROADWAY
EQUALEQUALB + 2"
XXX
X
3"
10"
3 5 /8"
6'-0" TYP.
BE
TW
EE
N
PO
ST
S
4" O.D. POST
8" SQ. STEEL
STANCHION
4" O.D. POST
8" SQ. STEEL STANCHION
THIS POST IN FLUSH
WITH STANCHION
CONCRETE 3000 PSI MIN.
LEFT to Open
FENCELINE
OUTSIDE
-FINISHED ROAD GRADE-
B1 SLIDE GATE FOUNDATION
NTS
ELEVATION
PLAN
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
IS
SU
ED
F
OR
B
ID
CS515
DON ELLIOT 12/19/19
PR
OFESS I ONAL
ENG I N E E R
NO
RTH CAROL I NA
CASS NDRA L Z WART
SEAL
049323
C4 AIRSIDE CONCRETE PAVEMENT
12" PORTLAND CEMENT CONCRETE
REINFORCEMENT (FOR PANELS
DESIGNATED WITH "R" ONLY)
8" NCDOT ABC
12" CEMENT STABILIZED SUBGRADE
T
T/
EXISTING
SUBGRADE
2" ASPHALT INTERMEDIATE COURSE, NCDOT I19.0C
TACK COAT
AIR OPERATIONS
12" CEMENT STABILIZED SUBGRADE
ATCT
12" IMPORTED SELECT MATERIAL
SUBBASE
EXISTING SUBGRADE
1-1/2" ASPHALT SURFACE COURSE, NCDOT SM-9.5B PLACE
TOP LIFT ONLY AFTER MAJOR CONSTRUCTION ACTIVITIES
ARE COMPLETE
PRIME COAT
C2 LANDSIDE HEAVY DUTY ASPHALT PAVEMENT
8" NCDOT ABC
C3 LANDSIDE CONCRETE PAVEMENT
8" PORTLAND CEMENT CONCRETE
REINFORCEMENT (FOR PANELS
DESIGNATED WITH "R" ONLY)
12" IMPORTED SELECT
MATERIAL SUBBASE
T
T/
EXISTING
SUBGRADE
6" NCDOT ABC
NTS NTS NTS
8" POROUS FILL
STRIP DRAIN, SEE PLANS FOR LOCATIONS
ATCT
GEOTEXTILE FABRIC
GEOTEXTILE FABRIC
4" M
IN
GEOTEXTILE FABRIC
C1 FOUNDATION SECTION
NTS
SPREAD OR WALL FOOTING
SEE STRUCTURAL PLANS
3'- 0"
3'-0"
WOVEN GEOTEXTILE.
REFER TO NOTE 1.
NO. 57 STONE BASE COURSE
COMPACTED FILL
REFER TO PLAN
B/FOUNDATION
IN SITU SOIL
6" NCDOT ABC
COR APPROVED COMPACTED SUBGRADE,
COMPACTED TO 95% MODIFIED PROCTOR
ASTM D 1557
2" ASPHALT SURFACE COURSE, NCDOT SM-9.5B
PRIME COAT
A4 LANDSIDE LIGHT DUTY ASPHALT PAVEMENT
NTS
NOTE:
1. WOVEN GEOTEXTILE MUST CONFORM TO AASHTO M288 CLASS 1,
ELONGATION <50%. OVERLAP SEAMS 24".
2. PROVIDE OVEREXCAVATION FOR BUILDING FOUNDATIONS AND
FOOTINGS .
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
FY
P -2
A
TC
T
O W
E R
A N
D A
IR
O
P E
R A
TI
O
N S
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
IS
SU
ED
F
OR
B
ID
CS516
DON ELLIOT 12/19/19
PR
OFESS I ONAL
ENG I N E E R
NO
RTH CAROL I NA
CASS NDRA L Z WART
SEAL
049323
| CS511 CIVIL SITE DETAILS - 11 |
| CS512 CIVIL SITE DETAILS - 12 |
| CS513 CIVIL SITE DETAILS - 13 |
| CS514 CIVIL SITE DETAILS - 14 |
| CS515 CIVIL SITE DETAILS - 15 |
| CS516 CIVIL SITE DETAILS - 16 |
2022-08-15T07:06:58-0400
| 2022-09-22T09:11:08-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:11:39-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:11:40-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:11:40-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:11:41-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:11:41-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:11:53-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:12:09-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:12:10-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:12:10-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:12:11-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-09-22T09:12:12-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
File details come from the government source that posted it. Updated .