1596300_dwg_24of35_V2_Architectural.pdf

PDF 19 MB Posted

Attached to
Design Bid-Build P228 ATC Tower and Air Operations, Marine Corps Air Station, Cherry Point, North Carolina
Solicitation number
N4008522R2504
Issued by

View the file

Other files

File Type Posted
AMEND 0010 UPDATED WAGE DETERMINATION FOR P228.pdf PDF
AMENDMENT 0011 FOR P228 ATC TOWER.pdf PDF
AMENDMENT 0009.pdf PDF
Amendment 0008.pdf PDF
AMENDMENT 0007 FOR P228.pdf PDF
UPDATED REVISED BID SCHEDULE FOR P228.pdf PDF
AMENDMENT 0006 FOR P228.pdf PDF
PPI LOG 04 FOR P228.pdf PDF
AMENDMENT 0005 FOR P228.pdf PDF
UPDATED BID SCHEDULE FOR P228.pdf PDF
P228 PPI LOG 03.pdf PDF
P228 AMENDMENT 0004.pdf PDF
PPI LOG 02 FOR P228.pdf PDF
P228 AMENDMENT 0003.pdf PDF
P228 AMENDMENT 0003 DOCUMENT FOR PPI 4-7.pdf PDF
P228 AMENDMENT 0002.pdf PDF
AMENDMENT 0002-DRAWING REFERENCES.pdf PDF
P228 PPI LOG 01.pdf PDF
AMENDMENT 0001 FOR P228.pdf PDF
Site Visit Log P228.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
1596300_dwg_16of35_V1_Civil.pdf PDF
1596300_dwg_28of35_V3_Equipment.pdf PDF
1596300_dwg_05of35_V1_Civil.pdf PDF
1596300_dwg_14of35_V1_Civil.pdf PDF
1596300_dwg_33of35_V4_Electrical.pdf PDF
1596300_dwg_12of35_V1_Civil.pdf PDF
1596300_dwg_06of35_V1_Civil.pdf PDF
1596300_dwg_21of35_V1_Landscape.pdf PDF
RFP FOR P228 ATC TOWER.pdf PDF
1596300_dwg_23of35_V2_Structural.pdf PDF
1596300_dwg_01of35_V1_General.pdf PDF
1596300_dwg_22of35_V2_General.pdf PDF
Attachment A - Pre-Propsal Injuiries Log.doc DOC document
1596300_dwg_17of35_V1_Civil.pdf PDF
1596300_dwg_09of35_V1_Civil.pdf PDF
1596300_dwg_15of35_V1_Civil.pdf PDF
Attachment E - Historical Small Business Utilization.docx DOCX document
1596300_dwg_04of35_V1_Survey-Geotechnical.pdf PDF
1596300_dwg_34of35_V4_Telecommunications.pdf PDF
1596300_dwg_26of35_V2_Interiors.pdf PDF
USCG MULTI-USE COMPLEX - 00 01 15 LIST OF DRAWINGS 100422.pdf PDF
Attachment F - Small Business Participation Commitment Document.docx DOCX document
ATTACHMENT B BID SCHEDULE FOR P228 ATC TOWER.pdf PDF
JA ML-23-07 CHPT P228 Fire Protection_Redacted.pdf PDF
Attachment H- PIEE Vendor Access Instructions.pdf PDF
1596300_dwg_35of35_V4_Telecommunications.pdf PDF
1596300_dwg_11of35_V1_Civil.pdf PDF
1596300_dwg_27of35_V3_General.pdf PDF
1596300_spc01of01.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR NUMBER

DOOR TAG

ARCHITECTURAL SYMBOLS

W

WINDOW TYPE LETTER

WINDOW TYPE TAG

SPECIALITY ITEM NUMBER

SPECIALITY ITEM TAG

PARTITION TYPE DESIGNATION

(REFER TO PARTITION SCHEDULE)

PARTITION TYPE TAG

S1AA

PARTITION IN PLAN

LOUVER TYPE LETTER

LOUVER TYPE TAG

L

1. WORK MUST COMPLY WITH APPLICABLE CODES AND STANDARDS AS

LISTED OR REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY

CRITERIA OR AS REQUIRED BY THE AUTHORITY HAVING

JURISDICTION.

2. DIMENSIONS GOVERN. DETAILS GOVERN OVER PLANS AND

ELEVATIONS. LARGE SCALE DETAILS OR PLANS GOVERN OVER

SMALL SCALE DETAILS OR PLANS. DO NOT SCALE DRAWINGS.

3. MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR

SPECIFIED ARE DONE SO TO ESTABLISH A MINIMUM LEVEL OF

QUALITY.

4. CONSTRUCTION MEET OR EXCEED LOCAL INDUSTRY STANDARDS.

DETAILS ARE PROVIDED TO INDICATE MINIMUM QUALITY AND TO

GIVE STANDARDS OF CONSTRUCTION. INCORPORATE SIMILAR

DETAILS AT SIMILAR CONDITIONS UNLESS NOTED OTHERWISE.

5. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS,

SECTIONS OR ELEVATIONS.

6. PAINT, STAIN, OR COAT EXPOSED SURFACES OF CONSTRUCTION

UNLESS NOTED OTHERWISE OR IF SURFACES ARE PRE-FINISHED.

7. OPENING DIMENSIONS ARE NOMINAL. FIELD MEASURE OPENINGS

AND COORDINATE WITH THE APPROPRIATE SUPPLIER FOR DOORS

AND WINDOWS.

8. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS,

WHERE REQUIRED.

9. SEAL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR AND

INTERIOR SURFACES AGAINST MOISTURE AND AIR INFILTRATION.

10. SEAL AROUND DOOR AND WINDOW FRAMES, COUNTERTOPS, WALL-

MOUNTED FIXTURES AND EQUIPMENT TO ADJACENT WALL

SURFACES.

11. COORDINATE PENETRATIONS IN THE STRUCTURE FOR THE PROPER

INSTALLATION OF THE WORK. REFER TO STRUCTURAL DRAWINGS

FOR SECONDARY FRAMING AND OR REINFORCING REQUIRED AT

PENETRATIONS IN STEEL, CONCRETE OR MASONRY.

12. PROVIDE ACCESS DOORS OR PANELS AS REQUIRED FOR SERVICING

OF PIPING, DUCTWORK, CABLE TRAYS, FIRE DAMPERS AND SIMILAR

APPLICATIONS. SUBMIT PROPOSED ACCESS DOOR LOCATIONS FOR

APPROVAL PRIOR TO INSTALLATION.

13. PROVIDE HVAC, PLUMBING, GAS OR ELECTRIC SERVICE

CONNECTIONS TO CASEWORK, FIXTURES, SIGNAGE, OR EQUIPMENT

INDICATED (WHETHER UNITS ARE INSTALLED BY CONTRACTOR OR

BY OTHERS).

14. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS, SUSPENDED

ITEMS, ETC. ONLY TO STRUCTURAL ELEMENTS ABOVE. DO NOT

ANCHOR TO ROOF DECK, PLUMBING / SPRINKLER PIPES, DUCTWORK,

ELECTRICAL CONDUIT OR SIMILAR ELEMENTS.

15. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED

FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS

SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE

CONTRACTOR.

16. BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE

WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE

ACTUAL CONDITIONS MUST BE REPORTED TO THE CONTRACTING

OFFICER FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.

17. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS

UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE

CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE

PROPER AND TIMELY EXECUTION OF THE INSTALLERS WORK. DO

NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE

CORRECTED. INSTALLATION CONSTITUTES ACCEPTANCE OF THE

SUBSTRATE AND/OR CONDITIONS.

18. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS INDICATES THAT

THE CONDITIONS OR DIMENSION IS THE SAME OR REPRESENTATIVE

FOR SIMILAR CONDITIONS THROUGHOUT.

19. CONTROL JOINTS (CJ) MUST BE INSTALLED AT PARTITIONS. CJ AT

CONCRETE MASONRY UNIT PARTITIONS MUST BE MAXIMUM 40'-0"

O.C., UNLESS NOTED OTHERWISE ON DRAWINGS. REFER TO

ELEVATION DRAWINGS FOR EXTERIOR CONTROL JOINT LOCATIONS.

REVIEW CJ LOCATIONS WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION.

20. ISOLATE NON-BEARING PARTITIONS FROM THE BUILDING

STRUCTURE TO PREVENT TRANSFER OF BUILDING LOADS FROM THE

STRUCTURE TO THE PARTITIONS.

ROOM NAME

A1 A-101

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

A101 INTERIOR ELEVATION

TAG

INTERIOR ELEVATION NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SCALE

SHEET

REFERENCED FROM

EXTERIOR ELEVATION

TAG

ELEVATION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

A1 A-101

WALL / PARTIAL

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

GENERAL PROJECT SYMBOLS

A1 A-101

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

A1 A-101

BUILDING

KEYNOTE TAG

KEYNOTE NUMBER

PLAN

NORTH

SCALE

TRUE NORTH

A101 A1

OH

A1.

A1

A1.

A1.

A1

DETAIL TITLE

1/8" = 1'-0" (A-101) A1

DETAIL TITLE

1/8" = 1'-0" (A-101)

SHEET

REFERENCED FROM

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:3

A

M

A-001

A R C H

IT

E C T U R A L S Y M B O

LS

, L E G E N D S , A B B R E V

IA

T

IO

N S A N D N O

TE

S

LES

12801450

EV SF

1596300

ARCHITECTURAL ABBREVIATIONSMATERIALS LEGEND

CONRETE MASONRY UNIT

STEEL

EARTH/COMPACT FILL

BATT/LOOSE FILL INSULATION

POROUS FILL/GRAVEL

RIGID INSULATION

GYPSUM BOARD

DIMENSIONAL LUMBER

WOOD BLOCKING

S E

C T

IO

N

V

IE

W E

L E

V A

T

IO

N /P

L A

N V

IE

W

BRICK

ACOUSTICAL TILE

CERAMIC TILE

GLASS

SAND/MORTAR/PLASTER

ARCHITECTURAL GENERAL NOTES

-O-

O.H. OPPOSITE HAND

OC ON CENTER

OD OUTSIDE DIAMETER

OFF OFFICE

OPNG OPENING

OPP OPPOSITE

-P-

PA PUBLIC ADDRESS

PERIM PERIMETER

PKG PACKAGE

PL PLATE

PLMB PLUMBING

PLYWD PLYWOOD

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE

-R-

R RADIUS

R/A RETURN AIR

RAF RAISED ACCESS FLOOR

RCP REFLECTIVE CEILING PLAN

RECP RECEPTACLE

REFER,

RE:

REFERENCE

REINF REINFORCED

REQ'D REQUIRED

REV REVISION

RH RIGHT HAND

RO ROUGH OPENING

-S-

S SOUTH

S/A SUPPLY AIR

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SID STRUCTURAL INTERIOR

DESIGN

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE, AS IN "SQ FT"

STC SOUND TRANSMISSION

COEFFICIENT

STD STANDARD

STOR STORAGE

STRUCT STRUCTURAL

SUPP SUPPORT

SUSP SUSPENDED

SYS SYSTEM

-T-

TD TRENCH DRAIN

TECH TECHNICAL

THRU THROUGH

TLT TOILET

TO TOP OF, AS IN "TO STEEL"

TYP TYPICAL

-U-

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

-V-

VENT VENTILATE, VENTILATOR

VERT VERTICAL

VOL VOLUME

-W-

W WEST, WIDTH

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WATER HEATER

WT WEIGHT

-F-

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER WITH

WALL BRACKET

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FF&E FURNITURE, FIXTURES &

EQUIPMENT

FHC FIRE HOSE CABINET (WITH

EXTINGUISHER & BRACKET)

FHR FIRE HOSE REEL (WITH

EXTINGUISHER & BRACKET)

FIN FINISHED, FINISH

FLR FLOOR

FT FEET / FOOT

°F FAHRENHEIT

-G-

GA GAUGE

GALV GALVANIZED

GL GIRT LINE

GRTG GRATING

GYP GYPSUM

GYP BD GYPSUM BOARD

-H-

H HIGH

HD HAND

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATION & AIR

CONDITIONING

-I-

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

-J-

JAN JANITOR'S CLOSET

-L-

L LEFT, LONG, LENGTH

LAB LABORATORY

LAT LATITUDE

LAV LAVATORY

LB or # POUND

LH LEFT HAND

LONG LONGITUDE

LVR LOUVER

-M-

M METER

MACH MACHINE

MAINT MAINTENANCE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MM MILLIMETER

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

-N-

N NORTH

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTP NOTICE TO PROCEED

NTS NOT TO SCALE

-A-

A/E ARCHITECT/ENGINEER

ACOUST ACOUSTICAL

ADJ ADJACENT, ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHJ AUTHORITY HAVING

JURISDICTION

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

ARCH ARCHITECTURE, ARCHITECT

-B-

BD BOARD

BITUM BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BO BOTTOM OF, AS IN "BO STEEL"

BTWN BETWEEN

-C-

CAB CABINET

CCTV CLOSED CIRCUIT TELEVISION

CG CORNER GUARD

CID COMPREHENSIVE INTERIOR

DESIGN

CJ CONTROL JOINT,

CONSTRUCTION JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONSTR CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACT, CONTRACTOR

COORD COORDINATE

CORR CORRUGATED OR CORRIDOR

CU CUBIC

°C CELSIUS

-D-

DBL DOUBLE

DEMO DEMOLITION

DESCR DESCRIPTION

DET DETAIL

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DN DOWN

DR DOOR

DS DOWNSPOUT

DWG DRAWING

-E-

E EAST

EA EACH

EEW EMERGENCY EYEWASH

EEWS EMERGENCY EYEWASH &

SHOWER

EF EXHAUST FAN

EJ EXPANSION JOINT

EL ELEVATION, AS IN HEIGHT

ELAST ELASTOMERIC

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATOR, OR ELEVATION AS

IN NORTH ELEV

EQ EQUAL

EQUIP EQUIPMENT

ETC AND SO FORTH (ETCETERA)

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

PLYWOOD

CAST-IN-PLACE CONCRETE

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

1. SEE SPECIFICATION 07 05 23 FOR PRESSURE TESTING AN AIR BARRIER

SYSTEM FOR AIR TIGHTNESS.

2. REFERENCE WALL SECTIONS AND DETAILS FOR CONTINUOUS AIR BARRIER.

3. ROOF AIR BARRIER IS UNDERLAYMENT OVER GYPSUM SHEATHING.

4. AIR BARRIER AREA MUST BE FIELD VERIFIED BY CONTRACTOR.

5. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER SYSTEM AND

REQUIREMENTS.

6. SEAL PENETRATIONS AT EACH ZONE BOUNDARY FOR AIR TIGHTNESS.

8. BUILDING SERVICE ELEMENTS AT AIR BARRIER ZONE BOUNDARY MUST

BE SEALED FOR AIR TIGHTNESS.

9. CONSTRUCT THE FACILITY COMPONENTS TO MEET THE WHOLE

BUILDING AIR LEAKAGE RATE OF LESS THAN 0.25 CFM/SF AT 75

PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E779 TO MEET THE

ASHRAE 189.1 REQUIREMENTS.

10. PROVIDE CONTINUOUS AND CORRECTLY ALIGNED BUILDING ENVELOPE

INCLUDING THERMAL, MOISTURE, AND AIR BARRIERS AROUND EACH

FACILITY.

NOTE: WORK NOTES INDICATE AIR BARRIER COMPONENT

1. AIR BARRIER UNDER CONCRETE SLAB

2. UNDERLAYMENT OVER METAL ROOF DECK.

3. FLUID APPLIED AIR BARRIER.

4. ALUMINUM STOREFRONT SYSTEM.

5. SBS MODIFIED BITUMINOUS ROOF MEMBRANE.

6. AIR BARRIER COMPLIANT POLYURETHANE SPRAY FOAM FILL BETWEEN

VERTICAL AND HORIZONTAL SYSTEM TRANSITIONS WHERE SELF

ADHERED AIR BARRIER MEMBRANE IS NOT POSSIBLE. REFER TO

SPECIFICATION 07 27 36 FOR THERMAL BARRIER REQUIREMENTS.

AIR BARRIER BOUNDARY

ZONE 1

FLOOR AREA = 25,417 SF

WALL AREA = 16,818 SF

ROOF AREA = 18,533 SF

ALLOWABLE LEAKAGE RATE (ALR): 0.25 CFM/SF

ALR

6,354 CFM

4,205 CFM

4,633 CFM

TOTAL AREA = 60,768 SF 15,192 CFM

S

K

104 105

114 113

136133

123 124 125

100 137

142 143 145

120119

D1 A-011

D3 A-011

Q

F

J

H

3 4 7 8 11 13 14

9 12 15

A

E

L

5 6

C

B

S

K

207208209

D1 A-011

N

F

H

7 11 14

201A

9 12

E

L

5 6

FIRST FLOOR

100' - 0"

SECOND FLOOR

116' - 0"

ROOF

132' - 0"

2 1

3478111314

BASEMENT

90' - 6"

2 3

91215 56

TOP OF PARAPET

138' - 0"

FIRST FLOOR

100' - 0"

SECOND FLOOR

116' - 0"

ROOF

132' - 0"

R IS K

Q P N M FGJ H

EL

6 6

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:4

A

M

A-011

A

IR

O P S A

IR

B A R R

IE

R E N C

LO

S U R E P

LA

N S A N D S E C T

IO

N S

LES

12801451

RJM RJM

1596300

1/16" = 1'-0" A1

FIRST FLOOR

1/16" = 1'-0" B3

SECOND FLOOR

1/16" = 1'-0" D1

AIR BARRIER SECTION - SOUTH

1/16" = 1'-0"

D3

AIR BARRIER SECTION - EAST

ROOM SCHEDULE

NUMBER NAME

BASEMENT

056 BASE NODE VAULT

FIRST FLOOR

100 STAIR

101 VESTIBULE

102 ENTRY

103 ELEVATOR

104 MEN'S

105 WOMEN'S

106 MOTHERS RM

107 CORRIDOR

108 COMM

109 BASH

110 WEAPON STOR

111 WX CLASSROOM

112 TOILET / SHOWER

113 BUNK ROOM

114 BUNK ROOM

115 STAIR

116 WX OIC

117 WX SNCOIC

118 WX SUPERVISOR

119 WX SIPR

120 ASOS

121 WX FLOOR

122 F/C

123 F/C SNCOIC

124 F/C CIV

125 ODO

126 ELEV EQUIP

127 BUNK / LOCKER

129 BUNK ROOM

130 TOILET / SHOWER

131 CORRIDOR

132 ADMIN STOR

133 FLIGHT PLANNING ROOM

134 QUIET

135 JANITOR

136 KITCHEN / BREAK

137 LOUNGE

138 TOILET / SHOWER

139 STORAGE BAY

140 PRE-SCREEN

141 VESTIBULE

142 MEN

143 WOMEN

144 POST-SCREEN

145 WOMEN

146 MEN

147 BREAK

148 DISPATCH

149 VAL SUPERVISOR

150 LOCKER

151 MECH

152 MECHANICAL

153 ELEC

154 UPS

155 AIRFIELD LIGHTS

156 BASE NODE

SECOND FLOOR

200 STAIR

201 CORRIDOR

201A EQUIP. CLOSET

202 RECEPTION

203 ELEVATOR

204 STORAGE

205 ATCO

207 NAVAIR EASU

208 FOD CELL

209 AOPS

210 CONFERENCE ROOM

210A KITCHEN

211 JAN

212 COMM

213 WOMEN'S

214 MEN'S

215 STAIR

216 CHIEF

217 MGYSGT

218 OSPO

PLAN

NORTH

8' 16' 32'0'

PLAN

NORTH

8' 16' 32'0'

8' 16' 32'0'8' 16' 32'0'

GENERAL NOTES WORK NOTES

AIR BARRIER SUMMARY

LEGEND

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

1. SEE SPECIFICATION 07 05 23 FOR PRESSURE TESTING AN AIR

BARRIER SYSTEM FOR AIR TIGHTNESS.

2. REFERENCE WALL SECTIONS AND DETAILS FOR CONTINUOUS AIR

BARRIER.

3. ROOF AIR BARRIER IS MEMBRANE AIR BARRIER OVER GYPSUM

SHEATHING.

4. AIR BARRIER AREA MUST BE FIELD VERIFIED BY CONTRACTOR.

5. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER SYSTEM AND

REQUIREMENTS.

6. SEAL PENETRATIONS AT EACH ZONE BOUNDARY FOR AIR

TIGHTNESS.

8. BUILDING SERVICE ELEMENTS AT AIR BARRIER ZONE

BOUNDARY MUST BE SEALED FOR AIR TIGHTNESS.

9. CONSTRUCT THE FACILITY COMPONENTS TO MEET THE WHOLE

BUILDING AIR LEAKAGE RATE LESS THAN 0.25 CFM/SF AT 75

PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E779 TO

MEET THE ASHRAE 189.1 REQUIREMENTS.

10. PROVIDE CONTINUOUS AND CORRECTLY ALIGNED BUILDING

ENVELOPE INCLUDING THERMAL, MOISTURE AND AIR BARRIERS

AROUND EACH FACILITY.

NOTE: WORK NOTES INDICATE AIR BARRIER COMPONENT

1. AIR BARRIER UNDER CONCRETE SLAB.

2. MEMBRANE AIR BARRIER OVER METAL ROOF DECK.

3. FLUID APPLIED AIR BARRIER.

4. ALUMINUM STOREFRONT SYSTEM.

5. AIR BARRIER COMPLIANT POLYURETHANE SPRAY

FOAM FILL BETWEEN VERTICAL AND HORIZONTAL

SYSTEM TRANSITIONS WHERE SELF ADHERED AIR

BARRIER MEMBRANE IS NOT POSSIBLE. REFER TO

SPECIFICATION 07 27 36 FOR THERMAL BARRIER

REQUIREMENTS.

AIR BARRIER BOUNDARY

ZONE 1

FLOOR AREA = 21,755 SF

WALL AREA = 8,647 SF

ROOF AREA = 22,896 SF

ALLOWABLE LEAKAGE RATE (ALR): 0.25 CFM/SF

ALR

5,439 CFM

2,162 CFM

5,724 CFM

TOTAL AREA = 53,298 SF 13,325 CFM

3 4 5 6 71

A

B

C

D

E

G

F

125 126

173172171

131 132

D1 A-021

C1 A-021

TOWER FOOTPRINT

44.72.7

FIRST FLOOR

100' - 0"

ROOF

113' - 4"

34567 12

4.7 2.78

ROOF

113' - 4"

A B C D E GF

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-R A

N G

E -C e n tr a l_

C to s lo s k ie b u rn sm c d .c o m

.r v t

/1

/2

:1

:5

A

M

A-021

M

TR

A C O N A

IR

B A R R

IE

R E N C

LO

S U R E

LES

12801452

EV SF

1596300

1/16" = 1'-0" A1

FLOOR PLAN

PLAN

NORTH

8' 16' 32'0'

1/16" = 1'-0" D1

MTRACON - AIR BARRIER - SECTION 1

1/16" = 1'-0" C1

MTRACON - AIR BARRIER - SECTION 2

ROOM SCHEDULE

NUMBER NAME

000 STORAGE

101 CORRIDOR

102 ATCFO

103 ATC SNCOIC

104 ATC TRAINING OFFICE

105 COMM

106 ATC UNION OFFICE

107 ATC ADMIN STORAGE

108 ATCM STORAGE

109 TEST EQUIP.

110 STORAGE

111 JANITOR

112 ATC CONFERENCE ROOM

113 MOTHERS ROOM

114 MENS

115 WOMEN

116 ATC BREAK ROOM

117 FWO

118 ATC IFR ROOM

119 STARS SIMULATOR

120 LOCKERS

120 LOCKERS

121 ATCM SERVER

122 ATCM EQUIPMENT

122 ATCM EQUIPMENT

123 ATCM SUPPLY BAY

124 ATCM HAZMAT STORAGE

125 SUPPLY DESK

126 SET

127 ATCM BREAK ROOM

128 KITCHEN

129 VESTIBULE

130 ATCM CLASSROOM

131 ATCM UNION OFFICE

132 ATCM-SNOIC

133 ATCM-OIC

135 Room

141 ENTRANCE

142 OFFICE/OPS

143 RADIO STORAGE

143 RADIO STORAGE

144 OFFICE

144 OFFICE

144 OFFICE

145 CORRIDOR

146 CLASSROOM

147 STORAGE

148 WOMEN

149 MEN

149 RANGE CONTROL FACILITY

150 EQUIPMENT ROOM

151 RANGE CONTROL FACILITY

152 OFFICE

153 WOMEN

153 OFFICE

154 BREAK ROOM

155 JANITOR

155 OPEN OFFICE

156 JANITOR

157 STORAGE

158 OFFICE

159 OFFICE

160 OFFICE

161 OFFICE

171 MECHANICAL

172 UPS

173 ELECTRICAL

174 STORAGE

175 STORAGE

8' 16' 32'0'

8' 16' 32'0'

GENERAL NOTES

WORK NOTES

LEGEND

AIR BARRIER SUMMARY

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

DN

UP

DN

DN

UP

ELEVATOR

EMERGENCY COMMAND CENTER

STAIRS

ELECTRICAL

FP

MECHANICAL

COMM

JANITOR

A1 A-031

VESTIBULE

A1 A-031

CAB ADMIN

ELEVATOR

CORRIDOR

STAIRS

1. SEE SPECIFICATION 07 05 23 FOR PRESSURE TESTING AND AIR BARRIER

SYSTEM FOR AIR TIGHTNESS.

2. REFERENCE WALL SECTIONS AND DETAILS FOR CONTINUOUS AIR

BARRIER.

3. ROOF AIR BARRIER IS MEMBRANE AIR BARRIER OVER METAL DECK.

4. AIR BARRIER AREA MUST BE FIELD VERIFIED BY CONTRACTOR.

5. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER SYSTEM AND

REQUIREMENTS.

6. SEAL PENETRATIONS FOR ZONE BOUNDARY FOR AIR TIGHTNESS.

8. BUILDING SERVICE ELEMENTS AT AIR BARRIER ZONE BOUNDARY

MUST BE SEALED FOR AIR TIGHTNESS.

9. CONSTRUCT THE FACILITY COMPONENTS TO MEET THE WHOLE

BUILDING AIR LEAKAGE RATE LESS THAN 0.25 CFM/SF AT 75 PASCALS

WHEN TESTED IN ACCORDANCE WITH ASTM E779 TO MEET THE ASHRAE

189.1 REQUIREMENTS.

10. PROVIDE CONTINUOUS AND CORRECTLY ALIGNED BUILDING EVENLOPE

INCLUDING THERMAL, MOISTURE AND AIR BARRIERS AROUND EACH

FACILITY.

11. REFER TO MECHANICAL DRAWINGS FOR DUCT ATTACHMENTS TO BACK

OF LOUVERS. PROVIDE INSULATED BLANK OFF PANEL (PREFINISHED TO

MATCH LOUVER) AT BACK OF LOUVER TO INFILL FULL EXTENTS OF

LOUVER NOT UTILIZED BY DUCT ATTACHMENT. FULLY SEAL PERIMETER

OF LOUVER/BLANK OFF PANEL TO MAINTAIN AIR BARRIER.

NOTE: WORK NOTES INDICATE AIR BARRIER COMPONENT

1. FULLY GROUTED CMU WALL

2. ROOF MEMBRANE.

3. FLUID APPLIED AIR BARRIER.

4. ALUMINUM STOREFRONT SYSTEM/ PRE-INSULATED METAL PANEL

SYSTEM.

5. COMPOSITE PRECAST CONCRETE WALL PANEL

6. AIR BARRIER BELOW FLOOR SLABS

7. MEMBRANE AIR BARRIER OVER METAL ROOF DECK.

AIR BARRIER BOUNDARY

FLOOR AREA = 1,663.25 SF

WALL AREA = 1,493.59 SF

ROOF AREA = 1,064.44 SF

ZONE 1 (ATCT IS ALL ZONE 1)

ALR

415.81 CFM

373.40 CFM

266.11 CFM

GRAND TOTAL AREA: 27,045.67 SF

MAXIMUM LEAKAGE: 6,761.42 CFM

TOTAL AREA = 4,221.28 SF 1,055.32 CFM

WALL AREA = 9,119.44 SF

ALR

2,279.68 CFM

CAB - FLOOR AREA = 926.47 SF

CAB - WALL AREA = 2,345 SF

CAB - ROOF AREA = 1,618.70 SF

ALR

231.62 CFM

586.25 CFM

404.68 CFM

TOTAL AREA = 4,890.17 SF 1,222.55 CFM

2ND TO 6TH

WALL AREA = 5,920.93 SF

ALR

1,480.23 CFM8TH TO 11TH

ALLOWABLE LEAKAGE RATE (ALR): 0.25 CFM/SF

1ST

7TH WALL AREA = 1,823.88 SF

ALR

455.97 CFM

WALL AREA = 1,069.97 SF

ALR

267.49 CFM11.5TH

A1 A-031

CAB

21205

FLOOR 1

100' - 0"

ROOF 14

292' - 3"

RAF FLOOR 13

273' - 3"

A

LANDING 2

116' - 4"

FLOOR 3

132' - 8"

LANDING 4

149' - 0"

FLOOR 5

165' - 4"

LANDING 6

181' - 8"

FLOOR 7

198' - 0"

FLOOR 8

214' - 4"

FLOOR 9

230' - 8"

FLOOR 10

247' - 0"

FLOOR 11

257' - 6"

CAB SLAB/CATWALK

FLOOR 12

271' - 6"

B C

FLOOR 11.5

262' - 9"

SEE GEN. NOTE 11

A1 A-031

CORRIDOR

21102

STAIRS

21103

STAIR

21105

ELEVATOR EQUIPMENT

21201

MECHANICAL ROOM

21104

A1 A-031

A1 A-031

COMM

ELEVATOR

CORRIDOR

STAIRS

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-A T

C -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:2

:3

A

M

A-031

A

TC

T A

IR

B A R R

IE

R E N C

LO

S U R E P

LA

N

LES

12801453

EV SF

1596300

3/32" = 1'-0" C2

AIR BARRIER - FLOOR 1

3/32" = 1'-0" B3

AIR BARRIER - FLOOR 8-11

3/32" = 1'-0" A3

AIR BARRIER - CAB SLAB/CATWALK FLOOR 12

PLAN

NORTH

0' 8' 16' 32'4'

PLAN

NORTH

0' 8' 16' 32'4'

PLAN

NORTH

0' 8' 16' 32'4'

PLAN

NORTH

0' 8' 16' 32'4'

GENERAL NOTES

WORK NOTES

LEGEND

AIR BARRIER SUMMARY

1/16" = 1'-0" A1

ATCT - AIR BARRIER SECTION

8' 16' 32'0' 3/32" = 1'-0"

A2

AIR BARRIER - FLOOR 11.5

PLAN

NORTH

0' 8' 16' 32'4'

3/32" = 1'-0" C3

TYPICAL BLIND SHAFT (FLOOR 2 - FLOOR 6)

PLAN

NORTH

0' 8' 16' 32'4'3/32" = 1'-0" B2

AIR BARRIER - FLOOR 7

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

C1

A-202

B1

A-201

A1

A-201

A1

A-202

BASH

WX CLASSROOM

MECHANICAL

MEN'S

WOMEN'S

BUNK ROOM

113BUNK ROOM

WX SUPERVISOR

WX SNCOIC

WX OIC

ELEVATOR

STAIR

KITCHEN / BREAK

FLIGHT PLANNING ROOM

BUNK ROOM

BUNK / LOCKER

F/C SNCOIC

F/C CIV

ODO

STAIR

LOUNGE

TOILET / SHOWER

JANITOR

TOILET / SHOWER

DISPATCH

BREAK

LOCKER

VAL SUPERVISOR

MEN

WOMEN

WOMEN

MEN

STORAGE BAY

VESTIBULE

PRE-SCREEN

POST-SCREEN

MECH

AIRFIELD LIGHTS

CORRIDOR

CORRIDOR

ENTRY

F/C

WX FLOOR

COMM

R

I

C

B

ELEC

ELEV EQUIP

VESTIBULE

TOILET / SHOWER

QUIET

ADMIN STOR

BASE NODE

MOTHERS RM

WEAPON STOR

UPS

ASOS

WX SIPR

S

18' - 3"

8 1 /2"

70' - 0"

/2

103' - 9 1/2"

K

D

4' - 11 1/2" 4'

/4

9"

UP

UP

AREA A

AREA C

A R

E A

A

A R

E A

B

135.00°

.0

.0

135.00°

18' - 8"

M.O.

6' - 4" 13' - 2"

M.O.

3' - 4"

M.O.

6' - 4" 5' - 7 3/4"

M.O.

6' - 4" 6' - 8 1/2"

M .O

6'

4"

M .O

3'

8'

6"

M .O

3'

4"

2'

0"

M .O

4'

0" 5'

4"

M .O

4'

0" 5'

4"

M .O

4'

0" 6'

0"

M .O

4'

0" 5'

4"

M .O

4'

0" 1'

1/ 4"

EQ

EQ

M.O.

8' - 0" 8' - 0"

M.O.

8' - 0" 5' - 2"

M.O.

6' - 4" 5' - 2"

M.O.

8' - 0" 28' - 0"

M.O.

6' - 4" 3' - 8"

M .O

3'

4"

1' - 9 3/4"

M.O.

4' - 0" 6' - 0"

M.O.

4' - 0" 6' - 0"

M.O.

4' - 0" 6' - 0"

M.O.

8' - 0" 5' - 4"

M.O.

3' - 4" 9' - 4"

M.O.

8' - 0" 5' - 4 1/4"

M.O.

3' - 4"

2' - 7 3/4"

M.O.

3' - 4"3' - 0" 10' - 4" 6' - 0"

M.O.

8' - 0" 4' - 0"

M.O.

8' - 0" 5' - 8"

M.O.

6' - 4" 2' - 8"

M.O.

8' - 0" 5' - 4"

A1 A-301

C1 A-301

OPEN TO

ABOVE

W1

CW1

CW2

CW2

CW3

CW3

CW4

W4W4W4

W3

W3

W3

W3

W3

W3 W3 W3 W4 W4 W4 W4 W4

Q

P

N

M

F

G

J

H

3 4 7 8 11 13 14

9'

3/

4"

147' - 9 3/4"

M .O

28' - 0"

9 12 15

A

E

6' - 0"

L

5 6

BID OPTION : VEHICLE CANOPY.

SEE A-574 FOR DETAILS

C3 A-301

W1

W1

7'

/4

9' - 0"

7'

1' - 2 3/4"

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE

CONTINUOUS ACROSS DOOR OPENINGS.

3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO

PARTITION TYPES SHEET A-501.

4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF

GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.

6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT

UNDERCOUNTER / CABINET LOCATIONS.

7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH

INFORMATION.

8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND

FACE OF METAL STUD, UNLESS NOTED OTHERWISE.

10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED

OTHERWISE.

11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND

HALF TONE.

12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO

SHEETS A-603 AND A-604.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:4

A

M

A-100

A

IR

O P S F

LO

O R P

LA

N F

IR

S T F

LO

O R O V E R A

LL

LES

12801454

RJM RJM

1596300

3/32" = 1'-0" A1

AIR OPS - FLOOR PLAN - FIRST FLOOR - OVERALL

PLAN

NORTH

0' 8' 16' 32'4'

PLAN

NORTH

KEY PLAN

A

B

C

GENERAL NOTES

LEGEND

RAF - RAISED ACCESS FLOOR

(6" HIGH) TYPE AF-1

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

MEN'S

WOMEN'S

FLIGHT PLANNING ROOM

BUNK ROOM

BUNK / LOCKER

F/C SNCOIC

F/C CIV

ODO

STAIR

JANITOR

TOILET / SHOWER

CORRIDOR

ENTRY

F/C

COMM

R

I

C

B

ELEV EQUIP

ELEVATOR

ADMIN STOR

121A

2A

0B

102A

101A

101B105

VESTIBULE

QUIET

WX FLOOR

WX OIC

BUNK ROOM

BUNK ROOM

ASOS

STAIR

TOILET / SHOWER

S E

E A

-1

F O

R A

R E

A C

A R

E A

A

SEE A-102 FOR AREA B

AREA A

S

K

D

WX SUPERVISOR

WX SNCOIC

WX SIPR

5A

UP

UP

0"

/4

3' - 1 1/4" 5' - 2" 8' - 10 1/2" 9' - 0 1/4" 5' - 2 1/2"

5'

9'

1/

2"

6' - 7 3/4"

8' - 0"

18' - 3 1/4"

1' - 1 1/2"

6' - 10 1/4"

10' - 7" 10' - 6"

5'

1/

2"

/2

5'

2"

/2

8'

1/

4" 9'

3"

11' - 1 1/2" 5' - 2 1/2"

16' - 11 1/4" 6' - 3 1/4" 3' - 4" 6' - 5 1/2"

.0

A-403 B4

A-401 A2

A-403 A2

A-401 A1

A-404 A1

A-401 B1

115B

MOTHERS RM

S2FA

S2DA S2DA

S2DA

S2DA

S4FG

S4FD

S4DG

S2DA

S4DG

S2FA

S2FA

S2DA

S4DG

S4DG

S4DA

S2DB

F1BA

S3DA

S3FA

S3DA

S4DA S4DA

S3DA

S4DG

S4FG

3'

6"

7'

- 7 1/

4"

6 1 /2"

7'

- 7

1/ 4"

2'

- 0

3/ 4"

5'

0"

S4FD

OPEN TO

ABOVE

2B

CORRIDOR

CG

CG

18' - 9 1/2"

7 FT HT

6' - 0"

5' - 2 1/2"

F1CB

F1CBF1CBF1CBF1CB

F1CB

F1CB

F1CB

F1CB

F1CB

F1CB

W1

S4DA

S4DA

8'

1/

2"

4' - 0"

/2

S4DG

S4DG

S4DGS4DG

S2FAS2DA

S4FD

S4DA

S4FA

S2FA

S4DD

Q

P

N

M

F

G

J

H

3 4 7 8 11 13 14

A-511 A2

A-511 B1

A-511 A1

A-511 B3

A-511 A3

A-562

C1

C2

A-564 B2

S4DA

9 12

E

5' - 2 1/4"

FEC

L

5 6

W2

W2

10' - 0 1/2"

S2DA

W1

100A

M1HD

S4DA

F1CB

S4DA

2'

- 0

3/ 4"

S2DBS2DB

PN01 PN01

PN01

PN01

PN01

PN01

PN01

PN01

PN24

FL06

FL06

W3

W3

W3

W3

W3

W3 W3 W3 W4

PL05

EX19

A-511 A4

4' - 2"

C3 A-301

A-511 A4

A-511 B3

A-511 A2

3'

7"

3' - 7"

S4DG

S4DG

S2FA

S2FA

4'

/4

S1DA

F1BA

M1HG

SIM OPP

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE

CONTINUOUS ACROSS DOOR OPENINGS.

3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO

PARTITION TYPES SHEET A-501.

4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF

GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.

6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT

UNDERCOUNTER / CABINET LOCATIONS.

7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH

INFORMATION.

8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND

FACE OF METAL STUD, UNLESS NOTED OTHERWISE.

10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED

OTHERWISE.

11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND

HALF TONE.

12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO

SHEETS A-603 AND A-604.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:5

A

M

A-101

A

IR

O P S F

LO

O R P

LA

N F

IR

S T F

LO

O R A R E A A

LES

12801455

RJM RJM

1596300

1/8" = 1'-0" A1

AIR OPS - FLOOR PLAN - FIRST FLOOR - AREA A

PLAN

NORTH

KEY PLAN

A

B

C

PLAN

NORTH

4' 8' 16'0'

GENERAL NOTES

LEGEND

RECESSED WALK OFF MAT

RAF - RAISED ACCESS FLOOR

(6" HIGH) TYPE AF-1

WORK NOTES

EX19 BUILDING SIGNAGE, SEE B3/A-590 FOR DETAILS

FL06 ACCESS FLOORING

PL05 ELECTRIC WATER COOLER, BI-LEVEL WITH BOTTLE FILLER, RE: PLUMB

DWGS

PN01 GUTTER / DOWNSPOUT

PN24 CELL PHONE LOCKER STORAGE

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

BASH

WX CLASSROOM

MECHANICAL

STAIR

AIRFIELD LIGHTS

CORRIDOR

UPS

ELEC

153WEAPON STOR

B

109B

115B

5A

109A

BASE NODE

SEE A-101 FOR AREA A

AREA B

15' - 4" 20' - 6 3/4" 5' - 3 1/2"

8'

3/

4"

3' - 0"

5'

1/

2"

/4

"8' - 4 3/4"

18' - 9 3/4" 7' - 4"

1/ 2"

C1 A-301

S3DD S4DD

S4DA

M1HG

M1HG

S3DA

S3DA

S3DA

S3FD

S2DD S2DD M1HE

M1HG

F1BA

F1CB

F1CB

S4DA

S4FA

F1BA F1BA

3 4 7 8 11

A-404 A3

A-511 B2

S3FA

S4DE

9 12

A

5 6

F1BA1'

MOTHERS RM

PN27

PN26

PN01

PN01

PN01

PN01

PN01

M1HD

F1BA

M1HE

NOTE: BASE NODE

VAULT (056) BELOW PN37

TOILET / SHOWER

A-511 B2

M1HE

SIM OPP

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE

CONTINUOUS ACROSS DOOR OPENINGS.

3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO

PARTITION TYPES SHEET A-501.

4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF

GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.

6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT

UNDERCOUNTER / CABINET LOCATIONS.

7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH

INFORMATION.

8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND

FACE OF METAL STUD, UNLESS NOTED OTHERWISE.

10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED

OTHERWISE.

11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND

HALF TONE.

12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO

SHEETS A-603 AND A-604.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:5

A

M

A-102

A

IR

O P S F

LO

O R P

LA

N F

IR

S T F

LO

O R A R E A B

LES

12801456

RJM RJM

1596300

1/8" = 1'-0" A1

AIR OPS - FLOOR PLAN - FIRST FLOOR - AREA B

PLAN

NORTH

KEY PLAN

A

B

C

PLAN

NORTH

4' 8' 16'0'

GENERAL NOTESWORK NOTES

PN01 GUTTER / DOWNSPOUT

PN26 3'-0" X 3'-0" FLOOR ACCESS HATCH AND LADDER TO BASE NODE VAULT

BELOW

PN27 3'-0" X 3'-0" ROOF ACCESS HATCH AND LADDER ABOVE; SEE C3/A-545

PN37 4" H CONCRETE HOUSE KEEPING PAD, SEE A3/TN402. COORDINATE

FINAL DIMENSION WITH DC POWER PLANT APPROVED SHOP DRAWING

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

STAIR

DISPATCH

BREAK

LOCKER

VAL SUPERVISOR

MEN

WOMEN

WOMEN

MEN

STORAGE BAY

VESTIBULE

PRE-SCREEN

POST-SCREEN

MECH

140A

0C

0B

144A

144B

140D

1B

139A137

4C

150A

139C13 9B

144E

S E

E A

-1

F O

R A

R E

A A

A R

E A

C

S

13' - 11" 9' - 0 3/4" 26' - 8" 21' - 10 1/2"

16' - 1 1/4" 5' - 2" 23' - 0" 12' - 2" 11' - 5 3/4"

7' - 11 1/2" 7' - 3 1/4" 9'

3"

/4

/4

/4

5'

1/

2"

/4

/2

/4

8'

0"

A-401 B2

A-401 B3

TOILET / SHOWER

LOUNGE

KITCHEN / BREAK

CORRIDOR

S4DA S2FA

S4DA

S2FA

S2DA

S2DA

S2FA

S3DA

S2DB

S4FA

S2DA

F1CA

S4DA

M1HA

1A

F1CBF1CBF1CBF1CBF1CBF1CBF1CBF1CB

F1CB

F1CB

F1CB

F1CB

F1CBF1CB

150B

8' - 0"

9' - 0"

ALIGN

F1BA

M1HA

S4FA

S4FA

A-561 B1

B3

A-561

C1

A-564

C1

C2

E

S2DA

S2DA

RO11

PN28PN28PN28

RO11

PN31

PN30

PL05

PN01PN01PN01

PN01PN01

C3

W1

S2FA

S2DA

S2DA

4' - 4"

W4 W4 W4

W4W4W4W4

PN35

PN36

PN36

PN36

KITCHEN

ISLAND

A1/ A-561

PN35

EQ04

EQ03

1' - 4"

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE

CONTINUOUS ACROSS DOOR OPENINGS.

3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO

PARTITION TYPES SHEET A-501.

4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF

GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.

6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT

UNDERCOUNTER / CABINET LOCATIONS.

7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH

INFORMATION.

8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND

FACE OF METAL STUD, UNLESS NOTED OTHERWISE.

10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED

OTHERWISE.

11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND

HALF TONE.

12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO

SHEETS A-603 AND A-604.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:5

A

M

A-103

A

IR

O P S F

LO

O R P

LA

N F

IR

S T F

LO

O R A R E A C

LES

12801457

RJM RJM

1596300

1/8" = 1'-0" A1

AIR OPS - FLOOR PLAN - FIRST FLOOR - AREA C

PLAN

NORTH

4' 8' 16'0'

PLAN

NORTH

KEY PLAN

A

B

C

GENERAL NOTES

LEGEND

RECESSED WALK OFF MAT

WORK NOTES

EQ03 COMMERICAL WASHER (BASIS OF DESIGN TRISTATE LAUNDRY

EQUIPMENT MODEL #EXSM765)

EQ04 COMMERICAL DRYER (BASIS OF DESIGN TRISTATE LAUNDRY

EQUIPMENT MODEL #TD83); DRYER IS REQUIRED TO BE CAPABLE OF

EXHAUSTING THRU (2) 90 DEGREE ELBOWS AND 30 LINEAR FT OF 8"

DUCTWORK WITHOUT A BOOSTER FAN

PL05 ELECTRIC WATER COOLER, BI-LEVEL WITH BOTTLE FILLER, RE: PLUMB

DWGS

PN01 GUTTER / DOWNSPOUT

PN28 METAL WIRE WINDOW SCREEN

PN30 3 TIER LOCKERS

PN31 HDPE ADA BENCH WITH BACK SUPPORT, 20" DEEP (SEE B1/A-582)

PN35 HDPE BENCH, 20" DEEP (SEE B1/A-582)

PN36 BUILDING SIGNAGE, SEE B3/A-590 FOR DETAILS

RO11 PRE-MANUFACTURED METAL CANOPY; CENTER ON DOOR BELOW

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

B1

A-201

A1

A-201

A1

A-202

C

B

ELEVATOR

CHIEF

MGYSGT

OSPO

CONFERENCE ROOM

WOMEN'S

NAVAIR EASU

FOD CELL

AOPS

JAN

211COMM

STAIR

RECEPTION

CORRIDOR

STORAGE

ATCO

OPEN TO

BELOW

S

K

/4

3/ 4"

24' - 0" 14' - 0"

1' - 1 1/4"

8' - 0"

1' - 1 1/4"

1'

1/

4"

8'

0"

1'

1/

4"

26' - 2 3/4"

/4

9'

1/

4"

26' - 4 1/2" 9' - 2 1/2"

MEN'S

STAIR

DN

DN

DN

DN

4' - 2 3/4"

M.O.

4' - 0" 6' - 0"

M.O.

4' - 0" 6' - 0"

M.O.

4' - 0" 6' - 0"

M.O.

8' - 0" 4' - 4 1/2" 10' - 1 1/2"

3'

3"

M .O

4'

0" 5'

4"

M .O

4'

0" 6'

0"

M .O

4'

0" 5'

4"

M .O

4'

0" 5'

4"

M .O

4'

0"

1'

1/

4"

/4

2'

- 4

1/ 2"

0"

2'

- 7

1/ 2"

E Q

E Q

E Q

E Q

EQ EQ

EQ EQ

A1 A-301

C1 A-301

RO02

RO01

VALLEY

VA

LLE

Y

VALL

EY

VALL

EY

RIDGE

R

ID

G E

RO07

RO02

RO03

RO07

RO02

RO09

CW7

CW6

CW7

W4W3W3W3

W6

W6

W6

W6

W3

W3

W3

W3

W3

RO07

RO07

KITCHEN

210A

F

J

H

7 8 11 14

RO11

RO11

RO01

C4 A-522

9 12 15

A

E

L

RO09

C3 A-545

SLOPE

2" / 12"

SLOPE

2" / 12"

SLOPE

1" / 12"

S

LO

P E

2"

S

LO

P E

2"

EQUIP. CLOSET

201A

PN34

RO12

RO12

/8

/8 " 6" 18' - 4 1/2"

RO17

RO17

C3 A-301

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:0

A

M

A-104

A

IR

O P S F

LO

O R P

LA

N S E C O N D F

LO

O R O V E R A

LL

LES

12801458

RJM RJM

1596300

3/32" = 1'-0" A1

AIR OPS - FLOOR PLAN - SECOND FLOOR - OVERALL

PLAN

NORTH

0' 8' 16' 32'4'

PLAN

NORTH

KEY PLAN

A

B

C

WORK NOTES

PN34 42" H GALV. STEEL GUARDRAIL WITH INFILL PANELS ON ALL SIDES OF

PARAPET. SEE C4/A-522 FOR DETAIL

RO01 PREFINISHED STANDING SEAM METAL ROOF ON R-30 INSULATION OVER

VAPOR BARRIER ON STRUCTURAL METAL DECK

RO02 PREFINISHED METAL GUTTER

RO03 PREFINISHED METAL DOWNSPOUT

RO07 TWO ROWS OF SNOW/ICE GUARDS

RO09 EXTERIOR ROOF ACCESS LADDER. REFER TO DETAIL A3/A-546

RO11 PRE-MANUFACTURED METAL CANOPY; CENTER ON DOOR BELOW

RO12 PREFINISHED METAL SCUPPER COLLECTOR BOX

RO17 ROOF TIE-DOWN FIXED ANCHOR BY ROOFING CONTRACTOR

GENERAL NOTES

LEGEND

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE

CONTINUOUS ACROSS ALL DOOR OPENINGS.

3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO

PARTITION TYPES SHEET A-501.

4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF

GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.

6. CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK TRIM

AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET LOCATIONS.

7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH

INFORMATION.

8. PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN

WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR AND

WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP MOUNTING

SUPPORTS.

9. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

10. ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,

FACE OF METAL STUD, AND FACE OF PRECAST CONCRETE WALL PANEL,

UNLESS NOTED OTHERWISE.

11. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED

OTHERWISE.

12. FOR LOCKERS AND LOCKER BENCHES. PROVIDE BLOCKING AS

REQUIRED.

13. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED

MARKERBOARDS, TACKBOARDS, STORAGE UNITS, OR AV EQUIPMENT,

INCLUDING FLAT PANEL DISPLAYS. REFERENCE FURNITURE PLANS FOR

LOCATIONS OF WALL ACCESSORIES, MARKER BOARDS AND VISUAL

DISPLAY EQUIPMENT.

14. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND

HALFTONED.

15. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO

SHEET A-603 AND A-604.

RAF - RAISED ACCESS FLOOR

(18" HIGH) TYPE AF-1

ROOF PAVERS ON PEDESTALS

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

ELEVATOR

CHIEF

MGYSGT

OSPO

CONFERENCE ROOM

WOMEN'S

NAVAIR EASU

FOD CELL

AOPS

C

B

JAN

COMM

STAIR

RECEPTION

CORRIDOR

STORAGE

ATCO

218 21

0B

210A

OPEN TO

BELOW

S

K

MEN'S

STAIR

9'

3/

4"

3/

4" 9'

8"

9'

7"

0C

14' - 6" 6' - 6" 9' - 0" 6' - 0 1/4"

/2 " 6'

0"

6'

6"

12' - 8" 16' - 0" 16' - 3 3/4"

5'

3/

4"

5' - 6 3/4"

12' - 0 1/4"

9'

3/

4"

A-403 C4

A-401 A3

A-404 A2

A-403 A3

S2DA

S2DA

S2DA

S2DA S4DA

S4DA

S4DA

S2DA

S2DA S2DA

S2DA

S4DD

S4DD

H3ED H3ED

210D

WALL PROTECTION, TYP

S2DA

DN

DN

DN

DN

F1CA

F1CA

F1CA

F1CA

F1CA F1CA F1CA

F1CA

F1CA

F1CA

F1BA

F1BA

F1BA

F1BA

F1BA

F1BA

F1BAF1BA

F1BA

S4FA

S4DA

3' - 6"

2' - 0"

9' - 11"

KITCHEN

210A

S4DA

S4DA

S4DA

H3ED

H3ED

F

J

H

7 8 11 14

EQUIP. CLOSET

201A

1A

C

EN

TER

R

AF

EQ

C

EN

TER

R

AF

EQ

C

EN

TER

R

AF

EQ

C

EN

TER

R

AF

EQ

S2DA

S2DA

F1CA

S2DA

S2DA

4' - 7 3/4"

S2DA

A-561

C3

9 12

E

L

5 6

9"

9"

2'

4"

C2

A-505 PN29

PN32

S2DA

PN03

PN01

PN01

PN01

PN01

PN01

PN01

PN01

PN01

PN01 PN01

RO13

S1DB

W6

W6

W6

W6

W3

W3

W3

W3

W3

W3 W3 W3 W4

RO12

RO12

A-105 A3

PN19

A-511 B4

A-511 C1

A-511 C2

A-511 C3

A-545 A4

C3 A-301

A-545 A5

S4DD

A-511 B4

SIM

RO16

R

ID

G E

1/ 2"

/1 2"

S

LO

PE

1/ 2"

/1 2"

S

LO

PE

1/2"/12" SLOPE

/2

S L O

P E

VALLEY

V A

L L E

Y

C4 A-522

B2 A-522

SIM

RO12

RO12

CONFERENCE ROOM

D3 A-546

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:0

A

M

A-105

A

IR

O P S F

LO

O R P

LA

N S E C O N D F

LO

O R A R E A A

LES

12801459

RJM RJM

1596300

1/8" = 1'-0" A1

AIR OPS - FLOOR PLAN - SECOND FLOOR - AREA A

PLAN

NORTH

4' 8' 16'0' PLAN

NORTH

KEY PLAN

A

B

C

GENERAL NOTES

LEGEND

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE

CONTINUOUS ACROSS ALL DOOR OPENINGS.

3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO

PARTITION TYPES SHEET A-501.

4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF

GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.

6. CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK TRIM

AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET LOCATIONS.

7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH

INFORMATION.

8. PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN

WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR AND

WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP MOUNTING

SUPPORTS.

9. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

10. ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,

FACE OF METAL STUD, AND FACE OF PRECAST CONCRETE WALL PANEL,

UNLESS NOTED OTHERWISE.

11. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED

OTHERWISE.

12. FOR LOCKERS AND LOCKER BENCHES. PROVIDE BLOCKING AS

REQUIRED.

13. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED

MARKERBOARDS, TACKBOARDS, STORAGE UNITS, OR AV EQUIPMENT,

INCLUDING FLAT PANEL DISPLAYS. REFERENCE FURNITURE PLANS FOR

LOCATIONS OF WALL ACCESSORIES, MARKER BOARDS AND VISUAL

DISPLAY EQUIPMENT.

14. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND

HALFTONED.

15. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO

SHEET A-603 AND A-604.

RAF - RAISED ACCESS FLOOR

(18" HIGH)

LEVELING PAVERS ON PEDESTALS

WORK NOTES

PN01 GUTTER / DOWNSPOUT

PN03 MECHANICAL CHASE

PN19 MOP SHELF

PN29 ALUMINUM GUARDRAIL AND SHOE MOULDING WITH TEMPERED GLASS

INFILL PANELS (3 SIDES OF OPENING), SEE C2/A-505 FOR DETAIL

PN32 SIDE COILING FIRE AND SMOKE RATED DOOR

RO12 PREFINISHED METAL SCUPPER COLLECTOR BOX

RO13 EXTERIOR ROOF ACCESS LADDER, REFER: DETAIL A3/A-531

RO16 MODIFIED BITUMINOUS MEMBRANE ROOFING ON PROTECTION BOARD

AND RIGID INSULATION (R-30)

1/8" = 1'-0" A3

PLAN DETAIL - PATIO ROOF (BELOW PAVERS)

PLAN

NORTH

4' 8' 16'0'

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

B1

A-201

A1

A-201

A1

A-202

B

S

25' - 8" 14' - 4"

9'

1/

4"

26' - 2 1/4" 9' - 4 3/4"

/4

/4

26' - 5 3/4" 70' - 10 1/4"

8 3 /4"

0"

A1 A-301

RO02

RO01

RIDGE

R

ID

G E

VALLEY

VALLEY

VALLEY

ROOF PERIMETER BELOW

ROOF PERIMETER BELOW

RO07

RO07

RO09

ROOF PERIMETER

BELOW

0"

/2

1/2" / 12"

1/ 2"

1/

2"

RO02

RO01

RO07

RO07

RO02

RO01

RO02

RO07

RO02

A2 A-522

B2 A-522

RO12

SLOPE

2" / 12"

SLOPE

2" / 12"

S

LO

P E

2"

S

LO

P E

2"

SLOPE

1" / 12"

RO16

RO02

RO02

C3 A-301

A-511 C4

10' - 3 3/4"

/4

A1 A-522

ROOF AREA KEY PLAN

B

C

D

A

G

F

E

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:1

A

M

A-106

A

IR

O P S R O O F P

LA

N

LES

12801460

RJM RJM

1596300

3/32" = 1'-0" A1

AIR OPS - ROOF PLAN

WORK NOTES

RO01 PREFINISHED STANDING SEAM METAL ROOF ON R-30 INSULATION OVER

VAPOR BARRIER ON STRUCTURAL METAL DECK

RO02 PREFINISHED METAL GUTTER

RO07 TWO ROWS OF SNOW/ICE GUARDS

RO09 EXTERIOR ROOF ACCESS LADDER. REFER TO DETAIL A3/A-546

RO12 PREFINISHED METAL SCUPPER COLLECTOR BOX

RO16 MODIFIED BITUMINOUS MEMBRANE ROOFING ON PROTECTION BOARD AND

RIGID INSULATION (R-30)

PLAN

NORTH

0' 8' 16' 32'4'

PLAN

NORTH

KEY PLAN

A

B

C

ROOF DRAINAGE CALCULATIONS

ROOF

AREA SLOPE

AREA

(SF)

ADDED

ROOF

AREA

(SF)

PITCH

FACTOR

(SMACNA

TABLE 1-1)

DESIGN

AREA

(SF)

DOWNSPOUT

QTY

DS

AREA/290*

PER 100 YR

MINIMUM

DOWNSPOUT

SIZE (IN)

DOWNSPOU

T PROVIDED

(IN)

RAINFALL

INTENSITY IA

MAX

GUTTER

LENGTH

(FT)

MINIMUM

GUTTER

DIMENSION

(IN)

PROVIDED

GUTTER

WIDTH X

DEPTH

A 2/12 1,386 0 1.00 1,386 2 2.39 1.75 W X 2.25 D 3 W X 4 D 4.1 2,841 28 4 X 4 6 X 6

B 1/2 / 12 510 0 1.00 510 2 0.88 1.75 W X 2.25 D 3 W X 4 D 4.1 1,046 44 3 X 3 6 X 6

C 2/12 1,360 0 1.00 1,360 2 2.34 1.75 W X 2.25 D 3 W X 4 D 4.1 2,788 29 4 X 4 6 X 6

D 2/12 2,898 0 1.00 2,898 6 1.67 1.75 W X 2.25 D 3 W X 4 D 4.1 1,980 33 4 X 4 6 X 6

E 2/12 3,364 54 1.00 3,418 3 3.93 1.75 W X 2.25 D 3 W X 4 D 4.1 4,671 48 5 X 5 6 X 6

F 2/12 7,711 2,898 1.00 10,609 6 6.10 3 W X 4 D 3 W X 4 D 4.1 7,249 46 6 X 6 6 X 6

G 2/12 2,023 54 1.00 2,077 2 3.58 1.75 W X 2.25 D 3 W X 4 D 4.1 4,258 31 5 X 5 6 X 6

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

R

I

C

B

MEN'S

WOMEN'S

BUNK ROOM

BUNK ROOM

WX SUPERVISOR

WX SNCOIC

WX OIC

ELEVATOR

ELEV EQUIP

STAIR

FLIGHT PLANNING ROOM

BUNK ROOM

BUNK / LOCKER

F/C SNCOIC

F/C CIV

ODO

STAIR

JANITOR

TOILET / SHOWER

CORRIDOR

CORRIDOR

VESTIBULE

COMM

ENTRY

F/C

WX FLOOR

QUIET

ADMIN STOR

MOTHERS RM

ASOS

WX SIPR

9' - 0" A.F.F.

10' - 0" A.F.F.

OPEN TO

ABOVE

10' - 0" A.F.F.

S

K

D

8' - 0" A.F.F.

8' - 0" A.F.F.

8' - 0" A.F.F.

TOILET / SHOWER

8' - 0" A.F.F.

8' - 0" A.F.F.

S E

E A

-1

F O

R A

R E

A C

A R

E A

A

SEE A-108 FOR AREA B

AREA A

A1 A-301

10' - 0" A.F.F.

8' - 0" A.F.F.

8' - 0" A.F.F.

Q

P

N

M

F

G

J

H

3 4 7 8 11 13 149 12

E

L

5 6

2' - 4"

2' - 4"

2'

A

LI

G N

ALIGN

8' - 8 5/8"

135.00°

8' /8

.0

135.00°

.0

2' - 4"2' - 4"

B1 A-551

B1 A-551

A3 A-551

E Q

E Q

A3 A-551

SIM

1"

ME02ME02

ME02

ME02

ME02

ME02

C3 A-301

B4 A-551

B4 A-551

EQ EQ

T Y P O F

7'

3'

3' - 8"

TYP OF 4

7' - 0"

10' - 0" A.F.F.

9' - 0" A.F.F.

ACT-1: 2' x 2' ACOUSTICAL

CEILING TILE

GYPSUM BOARD - PAINT

RECESSED LIGHT

10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR

HVAC AIR SUPPLY GRILLE

HVAC EXHAUST OR RETURN GRILLE

EXIT SIGN

1' x 4' FIXTURE - SUSPENDED

2' x 4' FIXTURE - RECESSED

2' x 2' FIXTURE - RECESSED

EXPOSED CEILING; PAINT STRUCTURE

AND ROOF DECK ABOVE

4' FIXTURES - MULLION/WALL MOUNTED

MULLION LIGHTS

CEILING MATERIAL LEGEND

HVAC LINEAR SUPPLY DIFFUSER

ACCESS HATCH (12" X 12" OR 24" X 24")

EMERGENCY LIGHT FIXTURE - WALL MOUNTED

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

A

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

C

AS NOTED

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

F Y P -2 A T C T O W E R A N D A

IR

O P E R A T

IO

N S

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

FI

LE

N A

M E

P

LO

TT

E D

CJC/KDB

CGM

DSN

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

C

R e v it P ro je c ts

\B L D

G -P

-1

-A

-O P

S -C e n tr a l_

C to sl o s ki e b u rn sm c d .c o m

.r v t

/1

/2

:1

:1

A

M

A-107

A

IR

O P S R E F

LE

C

TE

D C E

IL

IN

G P

LA

N F

IR

S T F

LO

O R A R E A A

LES

12801461

RJM RJM

1596300

1/8" = 1'-0" A1

AIR OPS - REFLECTED CEILING PLAN - FIRST FLOOR - AREA A

PLAN

NORTH

KEY PLAN

A

B

C

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. ARCHITECTURAL CEILING PLANS INDICATE DIMENSIONING AND

PLACEMENT OF VARIOUS CEILING MOUNTED DEVICES. REFER TO MEP

DRAWINGS AND SPECIFICATIONS FOR OTHER INFORMATION FOR MEP

SYSTEMS INCLUDING BUT NOT LIMITED TO FIRE SUPPRESSION, FIRE

ALARM DEVICES, SECURITY DEVICES, EXIT DEVICES, DIFFUSERS,

LIGHTING, LIGHTING CONTROL DEVICES, AND ACCESS PANELS.

3. CEILING HEIGHTS ARE SHOWN TO HEIGHT ABOVE FINISH FLOOR.

4. CENTER CEILING GRIDS IN ROOMS UNLESS NOTED OTHERWISE.

5. CENTER LIGHTS, SPEAKERS, SPRINKLERS, SIGNAGE, STROBES AND

OTHER HARDWARE INSTALLED IN TILED CEILING SYSTEMS IN TILES IN

BOTH DIRECTIONS UNLESS NOTED OTHERWISE.

6. REFERENCE ROOM FINISH SCHEDULE FOR ADDITIONAL CEILING FINISH

INFORMATION.

7. CENTER CEILING MOUNTED EXIT SIGNS WITHIN DOOR FRAME OR

OPENING. MOUNT 4" OFF FACE OF WALL.

8. ALIGN SPRINKLERS, JUNCTION BOXES & SMOKE DETECTORS WITH

ADJACENT LIGHT FIXTURES, UNLESS NOTED OTHERWISE.

9. COORDINATE LOCATIONS OF CEILING ACCESS PANELS WITH THE

FINAL LOCATIONS OF MECHANICAL EQUIPMENT AS REQUIRED TO

SERVICE EQUIPMENT AND TO PROVIDE ACCESS TO ABOVE CEILING

EQUIPMENT.

10. AT CONTINUOUS RUNS OF GYPSUM BOARD ASSEMBLIES, PROVIDE

CONTROL JOINTS AT A MAXIMUM OF (1) PER 50 FEET, NOT TO EXCEED

INDIVIDUAL AREAS OF 2,500 SQUARE FEET. SEE D4 ON SHEET A-553.

11. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT SOFFITS AND

CEILINGS OF RESTROOMS, LOCKER ROOMS, SHOWERS AND OTHER

WET AREAS.

12. CEILINGS ARE 9'-0 ABOVE FINISH FLOOR, UNLESS OTHERWISE NOTED.

PLAN

NORTH

4' 8' 16'0'

GENERAL REFLECTED CEILING PLAN

NOTES

WORK NOTES

ME02 ACCESS PANEL; COORDINATE WITH MECH. DAMPERS

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R B

ID

/1 8/

PIR

HSS

C

B

ELEC

MECHANICAL

BASH

WX CLASSROOM

AIRFIELD LIGHTS

CORRIDOR

COMM

BASE NODE

MOTHERS RM

WEAPON STOR

110 UPS

D

SEE A-107 FOR AREA A

AREA B

C1 A-301

3 4 7 8 119 12

A

5 6

TOILET / SHOWER

STAIR

WX OIC

MEN'S

WOMEN'S

C3 A-301

B1 A-551

A3 A-551

3'

6"

3' - 6"

ACT-1: 2' x 2' ACOUSTICAL

CEILING TILE

GYPSUM BOARD - PAINT

RECESSED LIGHT

10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR

HVAC AIR SUPPLY GRILLE

HVAC EXHAUST OR RETURN GRILLE

EXIT SIGN

1' x 4' FIXTURE - SUSPENDED

2' x 4' FIXTURE - RECESSED

2' x 2' FIXTURE - RECESSED

EXPOSED CEILING; PAINT STRUCTURE

AND ROOF DECK ABOVE

4' FIXTURES - MULLION/WALL MOUNTED

MULLION LIGHTS

CEILING MATERIAL LEGEND

HVAC LINEAR SUPPLY DIFFUSER

ACCESS HATCH (12" X 12" OR 24" X 24")

EMERGENCY LIGHT FIXTURE - WALL MOUNTED

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

M A

R

IN

E C

O R

P S

I P

T N

A V

A L

S T

A T

IO

N

N

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .