DOOR NUMBER
DOOR TAG
ARCHITECTURAL SYMBOLS
W
WINDOW TYPE LETTER
WINDOW TYPE TAG
SPECIALITY ITEM NUMBER
SPECIALITY ITEM TAG
PARTITION TYPE DESIGNATION
(REFER TO PARTITION SCHEDULE)
PARTITION TYPE TAG
S1AA
PARTITION IN PLAN
LOUVER TYPE LETTER
LOUVER TYPE TAG
L
1. WORK MUST COMPLY WITH APPLICABLE CODES AND STANDARDS AS
LISTED OR REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY
CRITERIA OR AS REQUIRED BY THE AUTHORITY HAVING
JURISDICTION.
2. DIMENSIONS GOVERN. DETAILS GOVERN OVER PLANS AND
ELEVATIONS. LARGE SCALE DETAILS OR PLANS GOVERN OVER
SMALL SCALE DETAILS OR PLANS. DO NOT SCALE DRAWINGS.
3. MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR
SPECIFIED ARE DONE SO TO ESTABLISH A MINIMUM LEVEL OF
QUALITY.
4. CONSTRUCTION MEET OR EXCEED LOCAL INDUSTRY STANDARDS.
DETAILS ARE PROVIDED TO INDICATE MINIMUM QUALITY AND TO
GIVE STANDARDS OF CONSTRUCTION. INCORPORATE SIMILAR
DETAILS AT SIMILAR CONDITIONS UNLESS NOTED OTHERWISE.
5. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS,
SECTIONS OR ELEVATIONS.
6. PAINT, STAIN, OR COAT EXPOSED SURFACES OF CONSTRUCTION
UNLESS NOTED OTHERWISE OR IF SURFACES ARE PRE-FINISHED.
7. OPENING DIMENSIONS ARE NOMINAL. FIELD MEASURE OPENINGS
AND COORDINATE WITH THE APPROPRIATE SUPPLIER FOR DOORS
AND WINDOWS.
8. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS,
WHERE REQUIRED.
9. SEAL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR AND
INTERIOR SURFACES AGAINST MOISTURE AND AIR INFILTRATION.
10. SEAL AROUND DOOR AND WINDOW FRAMES, COUNTERTOPS, WALL-
MOUNTED FIXTURES AND EQUIPMENT TO ADJACENT WALL
SURFACES.
11. COORDINATE PENETRATIONS IN THE STRUCTURE FOR THE PROPER
INSTALLATION OF THE WORK. REFER TO STRUCTURAL DRAWINGS
FOR SECONDARY FRAMING AND OR REINFORCING REQUIRED AT
PENETRATIONS IN STEEL, CONCRETE OR MASONRY.
12. PROVIDE ACCESS DOORS OR PANELS AS REQUIRED FOR SERVICING
OF PIPING, DUCTWORK, CABLE TRAYS, FIRE DAMPERS AND SIMILAR
APPLICATIONS. SUBMIT PROPOSED ACCESS DOOR LOCATIONS FOR
APPROVAL PRIOR TO INSTALLATION.
13. PROVIDE HVAC, PLUMBING, GAS OR ELECTRIC SERVICE
CONNECTIONS TO CASEWORK, FIXTURES, SIGNAGE, OR EQUIPMENT
INDICATED (WHETHER UNITS ARE INSTALLED BY CONTRACTOR OR
BY OTHERS).
14. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS, SUSPENDED
ITEMS, ETC. ONLY TO STRUCTURAL ELEMENTS ABOVE. DO NOT
ANCHOR TO ROOF DECK, PLUMBING / SPRINKLER PIPES, DUCTWORK,
ELECTRICAL CONDUIT OR SIMILAR ELEMENTS.
15. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED
FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS
SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE
CONTRACTOR.
16. BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE
WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE
ACTUAL CONDITIONS MUST BE REPORTED TO THE CONTRACTING
OFFICER FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
17. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS
UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE
CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE
PROPER AND TIMELY EXECUTION OF THE INSTALLERS WORK. DO
NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
CORRECTED. INSTALLATION CONSTITUTES ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
18. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS INDICATES THAT
THE CONDITIONS OR DIMENSION IS THE SAME OR REPRESENTATIVE
FOR SIMILAR CONDITIONS THROUGHOUT.
19. CONTROL JOINTS (CJ) MUST BE INSTALLED AT PARTITIONS. CJ AT
CONCRETE MASONRY UNIT PARTITIONS MUST BE MAXIMUM 40'-0"
O.C., UNLESS NOTED OTHERWISE ON DRAWINGS. REFER TO
ELEVATION DRAWINGS FOR EXTERIOR CONTROL JOINT LOCATIONS.
REVIEW CJ LOCATIONS WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION.
20. ISOLATE NON-BEARING PARTITIONS FROM THE BUILDING
STRUCTURE TO PREVENT TRANSFER OF BUILDING LOADS FROM THE
STRUCTURE TO THE PARTITIONS.
ROOM NAME
A1 A-101
ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
A101 INTERIOR ELEVATION
TAG
INTERIOR ELEVATION NUMBER
SHEET WHERE DRAWN
DETAIL NUMBER
SCALE
SHEET
REFERENCED FROM
EXTERIOR ELEVATION
TAG
ELEVATION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
A1 A-101
WALL / PARTIAL
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
GENERAL PROJECT SYMBOLS
A1 A-101
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
A1 A-101
BUILDING
KEYNOTE TAG
KEYNOTE NUMBER
PLAN
NORTH
SCALE
TRUE NORTH
A101 A1
OH
A1.
A1
A1.
A1.
A1
DETAIL TITLE
1/8" = 1'-0" (A-101) A1
DETAIL TITLE
1/8" = 1'-0" (A-101)
SHEET
REFERENCED FROM
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:3
A
M
A-001
A R C H
IT
E C T U R A L S Y M B O
LS
, L E G E N D S , A B B R E V
IA
T
IO
N S A N D N O
TE
S
LES
12801450
EV SF
1596300
ARCHITECTURAL ABBREVIATIONSMATERIALS LEGEND
CONRETE MASONRY UNIT
STEEL
EARTH/COMPACT FILL
BATT/LOOSE FILL INSULATION
POROUS FILL/GRAVEL
RIGID INSULATION
GYPSUM BOARD
DIMENSIONAL LUMBER
WOOD BLOCKING
S E
C T
IO
N
V
IE
W E
L E
V A
T
IO
N /P
L A
N V
IE
W
BRICK
ACOUSTICAL TILE
CERAMIC TILE
GLASS
SAND/MORTAR/PLASTER
ARCHITECTURAL GENERAL NOTES
-O-
O.H. OPPOSITE HAND
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
-P-
PA PUBLIC ADDRESS
PERIM PERIMETER
PKG PACKAGE
PL PLATE
PLMB PLUMBING
PLYWD PLYWOOD
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
-R-
R RADIUS
R/A RETURN AIR
RAF RAISED ACCESS FLOOR
RCP REFLECTIVE CEILING PLAN
RECP RECEPTACLE
REFER,
RE:
REFERENCE
REINF REINFORCED
REQ'D REQUIRED
REV REVISION
RH RIGHT HAND
RO ROUGH OPENING
-S-
S SOUTH
S/A SUPPLY AIR
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SID STRUCTURAL INTERIOR
DESIGN
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE, AS IN "SQ FT"
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STOR STORAGE
STRUCT STRUCTURAL
SUPP SUPPORT
SUSP SUSPENDED
SYS SYSTEM
-T-
TD TRENCH DRAIN
TECH TECHNICAL
THRU THROUGH
TLT TOILET
TO TOP OF, AS IN "TO STEEL"
TYP TYPICAL
-U-
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
-V-
VENT VENTILATE, VENTILATOR
VERT VERTICAL
VOL VOLUME
-W-
W WEST, WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WT WEIGHT
-F-
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER WITH
WALL BRACKET
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF&E FURNITURE, FIXTURES &
EQUIPMENT
FHC FIRE HOSE CABINET (WITH
EXTINGUISHER & BRACKET)
FHR FIRE HOSE REEL (WITH
EXTINGUISHER & BRACKET)
FIN FINISHED, FINISH
FLR FLOOR
FT FEET / FOOT
°F FAHRENHEIT
-G-
GA GAUGE
GALV GALVANIZED
GL GIRT LINE
GRTG GRATING
GYP GYPSUM
GYP BD GYPSUM BOARD
-H-
H HIGH
HD HAND
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
-I-
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
-J-
JAN JANITOR'S CLOSET
-L-
L LEFT, LONG, LENGTH
LAB LABORATORY
LAT LATITUDE
LAV LAVATORY
LB or # POUND
LH LEFT HAND
LONG LONGITUDE
LVR LOUVER
-M-
M METER
MACH MACHINE
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MM MILLIMETER
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
-N-
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTP NOTICE TO PROCEED
NTS NOT TO SCALE
-A-
A/E ARCHITECT/ENGINEER
ACOUST ACOUSTICAL
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING
JURISDICTION
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURE, ARCHITECT
-B-
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF, AS IN "BO STEEL"
BTWN BETWEEN
-C-
CAB CABINET
CCTV CLOSED CIRCUIT TELEVISION
CG CORNER GUARD
CID COMPREHENSIVE INTERIOR
DESIGN
CJ CONTROL JOINT,
CONSTRUCTION JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT, CONTRACTOR
COORD COORDINATE
CORR CORRUGATED OR CORRIDOR
CU CUBIC
°C CELSIUS
-D-
DBL DOUBLE
DEMO DEMOLITION
DESCR DESCRIPTION
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
-E-
E EAST
EA EACH
EEW EMERGENCY EYEWASH
EEWS EMERGENCY EYEWASH &
SHOWER
EF EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION, AS IN HEIGHT
ELAST ELASTOMERIC
ELEC ELECTRIC / ELECTRICAL
ELEV ELEVATOR, OR ELEVATION AS
IN NORTH ELEV
EQ EQUAL
EQUIP EQUIPMENT
ETC AND SO FORTH (ETCETERA)
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
PLYWOOD
CAST-IN-PLACE CONCRETE
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
1. SEE SPECIFICATION 07 05 23 FOR PRESSURE TESTING AN AIR BARRIER
SYSTEM FOR AIR TIGHTNESS.
2. REFERENCE WALL SECTIONS AND DETAILS FOR CONTINUOUS AIR BARRIER.
3. ROOF AIR BARRIER IS UNDERLAYMENT OVER GYPSUM SHEATHING.
4. AIR BARRIER AREA MUST BE FIELD VERIFIED BY CONTRACTOR.
5. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER SYSTEM AND
REQUIREMENTS.
6. SEAL PENETRATIONS AT EACH ZONE BOUNDARY FOR AIR TIGHTNESS.
8. BUILDING SERVICE ELEMENTS AT AIR BARRIER ZONE BOUNDARY MUST
BE SEALED FOR AIR TIGHTNESS.
9. CONSTRUCT THE FACILITY COMPONENTS TO MEET THE WHOLE
BUILDING AIR LEAKAGE RATE OF LESS THAN 0.25 CFM/SF AT 75
PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E779 TO MEET THE
ASHRAE 189.1 REQUIREMENTS.
10. PROVIDE CONTINUOUS AND CORRECTLY ALIGNED BUILDING ENVELOPE
INCLUDING THERMAL, MOISTURE, AND AIR BARRIERS AROUND EACH
FACILITY.
NOTE: WORK NOTES INDICATE AIR BARRIER COMPONENT
1. AIR BARRIER UNDER CONCRETE SLAB
2. UNDERLAYMENT OVER METAL ROOF DECK.
3. FLUID APPLIED AIR BARRIER.
4. ALUMINUM STOREFRONT SYSTEM.
5. SBS MODIFIED BITUMINOUS ROOF MEMBRANE.
6. AIR BARRIER COMPLIANT POLYURETHANE SPRAY FOAM FILL BETWEEN
VERTICAL AND HORIZONTAL SYSTEM TRANSITIONS WHERE SELF
ADHERED AIR BARRIER MEMBRANE IS NOT POSSIBLE. REFER TO
SPECIFICATION 07 27 36 FOR THERMAL BARRIER REQUIREMENTS.
AIR BARRIER BOUNDARY
ZONE 1
FLOOR AREA = 25,417 SF
WALL AREA = 16,818 SF
ROOF AREA = 18,533 SF
ALLOWABLE LEAKAGE RATE (ALR): 0.25 CFM/SF
ALR
6,354 CFM
4,205 CFM
4,633 CFM
TOTAL AREA = 60,768 SF 15,192 CFM
S
K
104 105
114 113
136133
123 124 125
100 137
142 143 145
120119
D1 A-011
D3 A-011
Q
F
J
H
3 4 7 8 11 13 14
9 12 15
A
E
L
5 6
C
B
S
K
207208209
D1 A-011
N
F
H
7 11 14
201A
9 12
E
L
5 6
FIRST FLOOR
100' - 0"
SECOND FLOOR
116' - 0"
ROOF
132' - 0"
2 1
3478111314
BASEMENT
90' - 6"
2 3
91215 56
TOP OF PARAPET
138' - 0"
FIRST FLOOR
100' - 0"
SECOND FLOOR
116' - 0"
ROOF
132' - 0"
R IS K
Q P N M FGJ H
EL
6 6
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:4
A
M
A-011
A
IR
O P S A
IR
B A R R
IE
R E N C
LO
S U R E P
LA
N S A N D S E C T
IO
N S
LES
12801451
RJM RJM
1596300
1/16" = 1'-0" A1
FIRST FLOOR
1/16" = 1'-0" B3
SECOND FLOOR
1/16" = 1'-0" D1
AIR BARRIER SECTION - SOUTH
1/16" = 1'-0"
D3
AIR BARRIER SECTION - EAST
ROOM SCHEDULE
NUMBER NAME
BASEMENT
056 BASE NODE VAULT
FIRST FLOOR
100 STAIR
101 VESTIBULE
102 ENTRY
103 ELEVATOR
104 MEN'S
105 WOMEN'S
106 MOTHERS RM
107 CORRIDOR
108 COMM
109 BASH
110 WEAPON STOR
111 WX CLASSROOM
112 TOILET / SHOWER
113 BUNK ROOM
114 BUNK ROOM
115 STAIR
116 WX OIC
117 WX SNCOIC
118 WX SUPERVISOR
119 WX SIPR
120 ASOS
121 WX FLOOR
122 F/C
123 F/C SNCOIC
124 F/C CIV
125 ODO
126 ELEV EQUIP
127 BUNK / LOCKER
129 BUNK ROOM
130 TOILET / SHOWER
131 CORRIDOR
132 ADMIN STOR
133 FLIGHT PLANNING ROOM
134 QUIET
135 JANITOR
136 KITCHEN / BREAK
137 LOUNGE
138 TOILET / SHOWER
139 STORAGE BAY
140 PRE-SCREEN
141 VESTIBULE
142 MEN
143 WOMEN
144 POST-SCREEN
145 WOMEN
146 MEN
147 BREAK
148 DISPATCH
149 VAL SUPERVISOR
150 LOCKER
151 MECH
152 MECHANICAL
153 ELEC
154 UPS
155 AIRFIELD LIGHTS
156 BASE NODE
SECOND FLOOR
200 STAIR
201 CORRIDOR
201A EQUIP. CLOSET
202 RECEPTION
203 ELEVATOR
204 STORAGE
205 ATCO
207 NAVAIR EASU
208 FOD CELL
209 AOPS
210 CONFERENCE ROOM
210A KITCHEN
211 JAN
212 COMM
213 WOMEN'S
214 MEN'S
215 STAIR
216 CHIEF
217 MGYSGT
218 OSPO
PLAN
NORTH
8' 16' 32'0'
PLAN
NORTH
8' 16' 32'0'
8' 16' 32'0'8' 16' 32'0'
GENERAL NOTES WORK NOTES
AIR BARRIER SUMMARY
LEGEND
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
1. SEE SPECIFICATION 07 05 23 FOR PRESSURE TESTING AN AIR
BARRIER SYSTEM FOR AIR TIGHTNESS.
2. REFERENCE WALL SECTIONS AND DETAILS FOR CONTINUOUS AIR
BARRIER.
3. ROOF AIR BARRIER IS MEMBRANE AIR BARRIER OVER GYPSUM
SHEATHING.
4. AIR BARRIER AREA MUST BE FIELD VERIFIED BY CONTRACTOR.
5. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER SYSTEM AND
REQUIREMENTS.
6. SEAL PENETRATIONS AT EACH ZONE BOUNDARY FOR AIR
TIGHTNESS.
8. BUILDING SERVICE ELEMENTS AT AIR BARRIER ZONE
BOUNDARY MUST BE SEALED FOR AIR TIGHTNESS.
9. CONSTRUCT THE FACILITY COMPONENTS TO MEET THE WHOLE
BUILDING AIR LEAKAGE RATE LESS THAN 0.25 CFM/SF AT 75
PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E779 TO
MEET THE ASHRAE 189.1 REQUIREMENTS.
10. PROVIDE CONTINUOUS AND CORRECTLY ALIGNED BUILDING
ENVELOPE INCLUDING THERMAL, MOISTURE AND AIR BARRIERS
AROUND EACH FACILITY.
NOTE: WORK NOTES INDICATE AIR BARRIER COMPONENT
1. AIR BARRIER UNDER CONCRETE SLAB.
2. MEMBRANE AIR BARRIER OVER METAL ROOF DECK.
3. FLUID APPLIED AIR BARRIER.
4. ALUMINUM STOREFRONT SYSTEM.
5. AIR BARRIER COMPLIANT POLYURETHANE SPRAY
FOAM FILL BETWEEN VERTICAL AND HORIZONTAL
SYSTEM TRANSITIONS WHERE SELF ADHERED AIR
BARRIER MEMBRANE IS NOT POSSIBLE. REFER TO
SPECIFICATION 07 27 36 FOR THERMAL BARRIER
REQUIREMENTS.
AIR BARRIER BOUNDARY
ZONE 1
FLOOR AREA = 21,755 SF
WALL AREA = 8,647 SF
ROOF AREA = 22,896 SF
ALLOWABLE LEAKAGE RATE (ALR): 0.25 CFM/SF
ALR
5,439 CFM
2,162 CFM
5,724 CFM
TOTAL AREA = 53,298 SF 13,325 CFM
3 4 5 6 71
A
B
C
D
E
G
F
125 126
173172171
131 132
D1 A-021
C1 A-021
TOWER FOOTPRINT
44.72.7
FIRST FLOOR
100' - 0"
ROOF
113' - 4"
34567 12
4.7 2.78
ROOF
113' - 4"
A B C D E GF
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-R A
N G
E -C e n tr a l_
C to s lo s k ie b u rn sm c d .c o m
.r v t
/1
/2
:1
:5
A
M
A-021
M
TR
A C O N A
IR
B A R R
IE
R E N C
LO
S U R E
LES
12801452
EV SF
1596300
1/16" = 1'-0" A1
FLOOR PLAN
PLAN
NORTH
8' 16' 32'0'
1/16" = 1'-0" D1
MTRACON - AIR BARRIER - SECTION 1
1/16" = 1'-0" C1
MTRACON - AIR BARRIER - SECTION 2
ROOM SCHEDULE
NUMBER NAME
000 STORAGE
101 CORRIDOR
102 ATCFO
103 ATC SNCOIC
104 ATC TRAINING OFFICE
105 COMM
106 ATC UNION OFFICE
107 ATC ADMIN STORAGE
108 ATCM STORAGE
109 TEST EQUIP.
110 STORAGE
111 JANITOR
112 ATC CONFERENCE ROOM
113 MOTHERS ROOM
114 MENS
115 WOMEN
116 ATC BREAK ROOM
117 FWO
118 ATC IFR ROOM
119 STARS SIMULATOR
120 LOCKERS
120 LOCKERS
121 ATCM SERVER
122 ATCM EQUIPMENT
122 ATCM EQUIPMENT
123 ATCM SUPPLY BAY
124 ATCM HAZMAT STORAGE
125 SUPPLY DESK
126 SET
127 ATCM BREAK ROOM
128 KITCHEN
129 VESTIBULE
130 ATCM CLASSROOM
131 ATCM UNION OFFICE
132 ATCM-SNOIC
133 ATCM-OIC
135 Room
141 ENTRANCE
142 OFFICE/OPS
143 RADIO STORAGE
143 RADIO STORAGE
144 OFFICE
144 OFFICE
144 OFFICE
145 CORRIDOR
146 CLASSROOM
147 STORAGE
148 WOMEN
149 MEN
149 RANGE CONTROL FACILITY
150 EQUIPMENT ROOM
151 RANGE CONTROL FACILITY
152 OFFICE
153 WOMEN
153 OFFICE
154 BREAK ROOM
155 JANITOR
155 OPEN OFFICE
156 JANITOR
157 STORAGE
158 OFFICE
159 OFFICE
160 OFFICE
161 OFFICE
171 MECHANICAL
172 UPS
173 ELECTRICAL
174 STORAGE
175 STORAGE
8' 16' 32'0'
8' 16' 32'0'
GENERAL NOTES
WORK NOTES
LEGEND
AIR BARRIER SUMMARY
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
DN
UP
DN
DN
UP
ELEVATOR
EMERGENCY COMMAND CENTER
STAIRS
ELECTRICAL
FP
MECHANICAL
COMM
JANITOR
A1 A-031
VESTIBULE
A1 A-031
CAB ADMIN
ELEVATOR
CORRIDOR
STAIRS
1. SEE SPECIFICATION 07 05 23 FOR PRESSURE TESTING AND AIR BARRIER
SYSTEM FOR AIR TIGHTNESS.
2. REFERENCE WALL SECTIONS AND DETAILS FOR CONTINUOUS AIR
BARRIER.
3. ROOF AIR BARRIER IS MEMBRANE AIR BARRIER OVER METAL DECK.
4. AIR BARRIER AREA MUST BE FIELD VERIFIED BY CONTRACTOR.
5. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER SYSTEM AND
REQUIREMENTS.
6. SEAL PENETRATIONS FOR ZONE BOUNDARY FOR AIR TIGHTNESS.
8. BUILDING SERVICE ELEMENTS AT AIR BARRIER ZONE BOUNDARY
MUST BE SEALED FOR AIR TIGHTNESS.
9. CONSTRUCT THE FACILITY COMPONENTS TO MEET THE WHOLE
BUILDING AIR LEAKAGE RATE LESS THAN 0.25 CFM/SF AT 75 PASCALS
WHEN TESTED IN ACCORDANCE WITH ASTM E779 TO MEET THE ASHRAE
189.1 REQUIREMENTS.
10. PROVIDE CONTINUOUS AND CORRECTLY ALIGNED BUILDING EVENLOPE
INCLUDING THERMAL, MOISTURE AND AIR BARRIERS AROUND EACH
FACILITY.
11. REFER TO MECHANICAL DRAWINGS FOR DUCT ATTACHMENTS TO BACK
OF LOUVERS. PROVIDE INSULATED BLANK OFF PANEL (PREFINISHED TO
MATCH LOUVER) AT BACK OF LOUVER TO INFILL FULL EXTENTS OF
LOUVER NOT UTILIZED BY DUCT ATTACHMENT. FULLY SEAL PERIMETER
OF LOUVER/BLANK OFF PANEL TO MAINTAIN AIR BARRIER.
NOTE: WORK NOTES INDICATE AIR BARRIER COMPONENT
1. FULLY GROUTED CMU WALL
2. ROOF MEMBRANE.
3. FLUID APPLIED AIR BARRIER.
4. ALUMINUM STOREFRONT SYSTEM/ PRE-INSULATED METAL PANEL
SYSTEM.
5. COMPOSITE PRECAST CONCRETE WALL PANEL
6. AIR BARRIER BELOW FLOOR SLABS
7. MEMBRANE AIR BARRIER OVER METAL ROOF DECK.
AIR BARRIER BOUNDARY
FLOOR AREA = 1,663.25 SF
WALL AREA = 1,493.59 SF
ROOF AREA = 1,064.44 SF
ZONE 1 (ATCT IS ALL ZONE 1)
ALR
415.81 CFM
373.40 CFM
266.11 CFM
GRAND TOTAL AREA: 27,045.67 SF
MAXIMUM LEAKAGE: 6,761.42 CFM
TOTAL AREA = 4,221.28 SF 1,055.32 CFM
WALL AREA = 9,119.44 SF
ALR
2,279.68 CFM
CAB - FLOOR AREA = 926.47 SF
CAB - WALL AREA = 2,345 SF
CAB - ROOF AREA = 1,618.70 SF
ALR
231.62 CFM
586.25 CFM
404.68 CFM
TOTAL AREA = 4,890.17 SF 1,222.55 CFM
2ND TO 6TH
WALL AREA = 5,920.93 SF
ALR
1,480.23 CFM8TH TO 11TH
ALLOWABLE LEAKAGE RATE (ALR): 0.25 CFM/SF
1ST
7TH WALL AREA = 1,823.88 SF
ALR
455.97 CFM
WALL AREA = 1,069.97 SF
ALR
267.49 CFM11.5TH
A1 A-031
CAB
21205
FLOOR 1
100' - 0"
ROOF 14
292' - 3"
RAF FLOOR 13
273' - 3"
A
LANDING 2
116' - 4"
FLOOR 3
132' - 8"
LANDING 4
149' - 0"
FLOOR 5
165' - 4"
LANDING 6
181' - 8"
FLOOR 7
198' - 0"
FLOOR 8
214' - 4"
FLOOR 9
230' - 8"
FLOOR 10
247' - 0"
FLOOR 11
257' - 6"
CAB SLAB/CATWALK
FLOOR 12
271' - 6"
B C
FLOOR 11.5
262' - 9"
SEE GEN. NOTE 11
A1 A-031
CORRIDOR
21102
STAIRS
21103
STAIR
21105
ELEVATOR EQUIPMENT
21201
MECHANICAL ROOM
21104
A1 A-031
A1 A-031
COMM
ELEVATOR
CORRIDOR
STAIRS
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-A T
C -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:2
:3
A
M
A-031
A
TC
T A
IR
B A R R
IE
R E N C
LO
S U R E P
LA
N
LES
12801453
EV SF
1596300
3/32" = 1'-0" C2
AIR BARRIER - FLOOR 1
3/32" = 1'-0" B3
AIR BARRIER - FLOOR 8-11
3/32" = 1'-0" A3
AIR BARRIER - CAB SLAB/CATWALK FLOOR 12
PLAN
NORTH
0' 8' 16' 32'4'
PLAN
NORTH
0' 8' 16' 32'4'
PLAN
NORTH
0' 8' 16' 32'4'
PLAN
NORTH
0' 8' 16' 32'4'
GENERAL NOTES
WORK NOTES
LEGEND
AIR BARRIER SUMMARY
1/16" = 1'-0" A1
ATCT - AIR BARRIER SECTION
8' 16' 32'0' 3/32" = 1'-0"
A2
AIR BARRIER - FLOOR 11.5
PLAN
NORTH
0' 8' 16' 32'4'
3/32" = 1'-0" C3
TYPICAL BLIND SHAFT (FLOOR 2 - FLOOR 6)
PLAN
NORTH
0' 8' 16' 32'4'3/32" = 1'-0" B2
AIR BARRIER - FLOOR 7
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
C1
A-202
B1
A-201
A1
A-201
A1
A-202
BASH
WX CLASSROOM
MECHANICAL
MEN'S
WOMEN'S
BUNK ROOM
113BUNK ROOM
WX SUPERVISOR
WX SNCOIC
WX OIC
ELEVATOR
STAIR
KITCHEN / BREAK
FLIGHT PLANNING ROOM
BUNK ROOM
BUNK / LOCKER
F/C SNCOIC
F/C CIV
ODO
STAIR
LOUNGE
TOILET / SHOWER
JANITOR
TOILET / SHOWER
DISPATCH
BREAK
LOCKER
VAL SUPERVISOR
MEN
WOMEN
WOMEN
MEN
STORAGE BAY
VESTIBULE
PRE-SCREEN
POST-SCREEN
MECH
AIRFIELD LIGHTS
CORRIDOR
CORRIDOR
ENTRY
F/C
WX FLOOR
COMM
R
I
C
B
ELEC
ELEV EQUIP
VESTIBULE
TOILET / SHOWER
QUIET
ADMIN STOR
BASE NODE
MOTHERS RM
WEAPON STOR
UPS
ASOS
WX SIPR
S
18' - 3"
8 1 /2"
70' - 0"
/2
103' - 9 1/2"
K
D
4' - 11 1/2" 4'
/4
9"
UP
UP
AREA A
AREA C
A R
E A
A
A R
E A
B
135.00°
.0
.0
135.00°
18' - 8"
M.O.
6' - 4" 13' - 2"
M.O.
3' - 4"
M.O.
6' - 4" 5' - 7 3/4"
M.O.
6' - 4" 6' - 8 1/2"
M .O
6'
4"
M .O
3'
8'
6"
M .O
3'
4"
2'
0"
M .O
4'
0" 5'
4"
M .O
4'
0" 5'
4"
M .O
4'
0" 6'
0"
M .O
4'
0" 5'
4"
M .O
4'
0" 1'
1/ 4"
EQ
EQ
M.O.
8' - 0" 8' - 0"
M.O.
8' - 0" 5' - 2"
M.O.
6' - 4" 5' - 2"
M.O.
8' - 0" 28' - 0"
M.O.
6' - 4" 3' - 8"
M .O
3'
4"
1' - 9 3/4"
M.O.
4' - 0" 6' - 0"
M.O.
4' - 0" 6' - 0"
M.O.
4' - 0" 6' - 0"
M.O.
8' - 0" 5' - 4"
M.O.
3' - 4" 9' - 4"
M.O.
8' - 0" 5' - 4 1/4"
M.O.
3' - 4"
2' - 7 3/4"
M.O.
3' - 4"3' - 0" 10' - 4" 6' - 0"
M.O.
8' - 0" 4' - 0"
M.O.
8' - 0" 5' - 8"
M.O.
6' - 4" 2' - 8"
M.O.
8' - 0" 5' - 4"
A1 A-301
C1 A-301
OPEN TO
ABOVE
W1
CW1
CW2
CW2
CW3
CW3
CW4
W4W4W4
W3
W3
W3
W3
W3
W3 W3 W3 W4 W4 W4 W4 W4
Q
P
N
M
F
G
J
H
3 4 7 8 11 13 14
9'
3/
4"
147' - 9 3/4"
M .O
28' - 0"
9 12 15
A
E
6' - 0"
L
5 6
BID OPTION : VEHICLE CANOPY.
SEE A-574 FOR DETAILS
C3 A-301
W1
W1
7'
/4
9' - 0"
7'
1' - 2 3/4"
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS DOOR OPENINGS.
3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO
PARTITION TYPES SHEET A-501.
4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.
6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT
UNDERCOUNTER / CABINET LOCATIONS.
7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION.
8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND
FACE OF METAL STUD, UNLESS NOTED OTHERWISE.
10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED
OTHERWISE.
11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND
HALF TONE.
12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO
SHEETS A-603 AND A-604.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:4
A
M
A-100
A
IR
O P S F
LO
O R P
LA
N F
IR
S T F
LO
O R O V E R A
LL
LES
12801454
RJM RJM
1596300
3/32" = 1'-0" A1
AIR OPS - FLOOR PLAN - FIRST FLOOR - OVERALL
PLAN
NORTH
0' 8' 16' 32'4'
PLAN
NORTH
KEY PLAN
A
B
C
GENERAL NOTES
LEGEND
RAF - RAISED ACCESS FLOOR
(6" HIGH) TYPE AF-1
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
MEN'S
WOMEN'S
FLIGHT PLANNING ROOM
BUNK ROOM
BUNK / LOCKER
F/C SNCOIC
F/C CIV
ODO
STAIR
JANITOR
TOILET / SHOWER
CORRIDOR
ENTRY
F/C
COMM
R
I
C
B
ELEV EQUIP
ELEVATOR
ADMIN STOR
121A
2A
0B
102A
101A
101B105
VESTIBULE
QUIET
WX FLOOR
WX OIC
BUNK ROOM
BUNK ROOM
ASOS
STAIR
TOILET / SHOWER
S E
E A
-1
F O
R A
R E
A C
A R
E A
A
SEE A-102 FOR AREA B
AREA A
S
K
D
WX SUPERVISOR
WX SNCOIC
WX SIPR
5A
UP
UP
0"
/4
3' - 1 1/4" 5' - 2" 8' - 10 1/2" 9' - 0 1/4" 5' - 2 1/2"
5'
9'
1/
2"
6' - 7 3/4"
8' - 0"
18' - 3 1/4"
1' - 1 1/2"
6' - 10 1/4"
10' - 7" 10' - 6"
5'
1/
2"
/2
5'
2"
/2
8'
1/
4" 9'
3"
11' - 1 1/2" 5' - 2 1/2"
16' - 11 1/4" 6' - 3 1/4" 3' - 4" 6' - 5 1/2"
.0
A-403 B4
A-401 A2
A-403 A2
A-401 A1
A-404 A1
A-401 B1
115B
MOTHERS RM
S2FA
S2DA S2DA
S2DA
S2DA
S4FG
S4FD
S4DG
S2DA
S4DG
S2FA
S2FA
S2DA
S4DG
S4DG
S4DA
S2DB
F1BA
S3DA
S3FA
S3DA
S4DA S4DA
S3DA
S4DG
S4FG
3'
6"
7'
- 7 1/
4"
6 1 /2"
7'
- 7
1/ 4"
2'
- 0
3/ 4"
5'
0"
S4FD
OPEN TO
ABOVE
2B
CORRIDOR
CG
CG
18' - 9 1/2"
7 FT HT
6' - 0"
5' - 2 1/2"
F1CB
F1CBF1CBF1CBF1CB
F1CB
F1CB
F1CB
F1CB
F1CB
F1CB
W1
S4DA
S4DA
8'
1/
2"
4' - 0"
/2
S4DG
S4DG
S4DGS4DG
S2FAS2DA
S4FD
S4DA
S4FA
S2FA
S4DD
Q
P
N
M
F
G
J
H
3 4 7 8 11 13 14
A-511 A2
A-511 B1
A-511 A1
A-511 B3
A-511 A3
A-562
C1
C2
A-564 B2
S4DA
9 12
E
5' - 2 1/4"
FEC
L
5 6
W2
W2
10' - 0 1/2"
S2DA
W1
100A
M1HD
S4DA
F1CB
S4DA
2'
- 0
3/ 4"
S2DBS2DB
PN01 PN01
PN01
PN01
PN01
PN01
PN01
PN01
PN24
FL06
FL06
W3
W3
W3
W3
W3
W3 W3 W3 W4
PL05
EX19
A-511 A4
4' - 2"
C3 A-301
A-511 A4
A-511 B3
A-511 A2
3'
7"
3' - 7"
S4DG
S4DG
S2FA
S2FA
4'
/4
S1DA
F1BA
M1HG
SIM OPP
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS DOOR OPENINGS.
3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO
PARTITION TYPES SHEET A-501.
4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.
6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT
UNDERCOUNTER / CABINET LOCATIONS.
7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION.
8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND
FACE OF METAL STUD, UNLESS NOTED OTHERWISE.
10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED
OTHERWISE.
11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND
HALF TONE.
12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO
SHEETS A-603 AND A-604.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:5
A
M
A-101
A
IR
O P S F
LO
O R P
LA
N F
IR
S T F
LO
O R A R E A A
LES
12801455
RJM RJM
1596300
1/8" = 1'-0" A1
AIR OPS - FLOOR PLAN - FIRST FLOOR - AREA A
PLAN
NORTH
KEY PLAN
A
B
C
PLAN
NORTH
4' 8' 16'0'
GENERAL NOTES
LEGEND
RECESSED WALK OFF MAT
RAF - RAISED ACCESS FLOOR
(6" HIGH) TYPE AF-1
WORK NOTES
EX19 BUILDING SIGNAGE, SEE B3/A-590 FOR DETAILS
FL06 ACCESS FLOORING
PL05 ELECTRIC WATER COOLER, BI-LEVEL WITH BOTTLE FILLER, RE: PLUMB
DWGS
PN01 GUTTER / DOWNSPOUT
PN24 CELL PHONE LOCKER STORAGE
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
BASH
WX CLASSROOM
MECHANICAL
STAIR
AIRFIELD LIGHTS
CORRIDOR
UPS
ELEC
153WEAPON STOR
B
109B
115B
5A
109A
BASE NODE
SEE A-101 FOR AREA A
AREA B
15' - 4" 20' - 6 3/4" 5' - 3 1/2"
8'
3/
4"
3' - 0"
5'
1/
2"
/4
"8' - 4 3/4"
18' - 9 3/4" 7' - 4"
1/ 2"
C1 A-301
S3DD S4DD
S4DA
M1HG
M1HG
S3DA
S3DA
S3DA
S3FD
S2DD S2DD M1HE
M1HG
F1BA
F1CB
F1CB
S4DA
S4FA
F1BA F1BA
3 4 7 8 11
A-404 A3
A-511 B2
S3FA
S4DE
9 12
A
5 6
F1BA1'
MOTHERS RM
PN27
PN26
PN01
PN01
PN01
PN01
PN01
M1HD
F1BA
M1HE
NOTE: BASE NODE
VAULT (056) BELOW PN37
TOILET / SHOWER
A-511 B2
M1HE
SIM OPP
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS DOOR OPENINGS.
3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO
PARTITION TYPES SHEET A-501.
4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.
6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT
UNDERCOUNTER / CABINET LOCATIONS.
7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION.
8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND
FACE OF METAL STUD, UNLESS NOTED OTHERWISE.
10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED
OTHERWISE.
11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND
HALF TONE.
12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO
SHEETS A-603 AND A-604.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:5
A
M
A-102
A
IR
O P S F
LO
O R P
LA
N F
IR
S T F
LO
O R A R E A B
LES
12801456
RJM RJM
1596300
1/8" = 1'-0" A1
AIR OPS - FLOOR PLAN - FIRST FLOOR - AREA B
PLAN
NORTH
KEY PLAN
A
B
C
PLAN
NORTH
4' 8' 16'0'
GENERAL NOTESWORK NOTES
PN01 GUTTER / DOWNSPOUT
PN26 3'-0" X 3'-0" FLOOR ACCESS HATCH AND LADDER TO BASE NODE VAULT
BELOW
PN27 3'-0" X 3'-0" ROOF ACCESS HATCH AND LADDER ABOVE; SEE C3/A-545
PN37 4" H CONCRETE HOUSE KEEPING PAD, SEE A3/TN402. COORDINATE
FINAL DIMENSION WITH DC POWER PLANT APPROVED SHOP DRAWING
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
STAIR
DISPATCH
BREAK
LOCKER
VAL SUPERVISOR
MEN
WOMEN
WOMEN
MEN
STORAGE BAY
VESTIBULE
PRE-SCREEN
POST-SCREEN
MECH
140A
0C
0B
144A
144B
140D
1B
139A137
4C
150A
139C13 9B
144E
S E
E A
-1
F O
R A
R E
A A
A R
E A
C
S
13' - 11" 9' - 0 3/4" 26' - 8" 21' - 10 1/2"
16' - 1 1/4" 5' - 2" 23' - 0" 12' - 2" 11' - 5 3/4"
7' - 11 1/2" 7' - 3 1/4" 9'
3"
/4
/4
/4
5'
1/
2"
/4
/2
/4
8'
0"
A-401 B2
A-401 B3
TOILET / SHOWER
LOUNGE
KITCHEN / BREAK
CORRIDOR
S4DA S2FA
S4DA
S2FA
S2DA
S2DA
S2FA
S3DA
S2DB
S4FA
S2DA
F1CA
S4DA
M1HA
1A
F1CBF1CBF1CBF1CBF1CBF1CBF1CBF1CB
F1CB
F1CB
F1CB
F1CB
F1CBF1CB
150B
8' - 0"
9' - 0"
ALIGN
F1BA
M1HA
S4FA
S4FA
A-561 B1
B3
A-561
C1
A-564
C1
C2
E
S2DA
S2DA
RO11
PN28PN28PN28
RO11
PN31
PN30
PL05
PN01PN01PN01
PN01PN01
C3
W1
S2FA
S2DA
S2DA
4' - 4"
W4 W4 W4
W4W4W4W4
PN35
PN36
PN36
PN36
KITCHEN
ISLAND
A1/ A-561
PN35
EQ04
EQ03
1' - 4"
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS DOOR OPENINGS.
3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO
PARTITION TYPES SHEET A-501.
4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.
6. COORDINATE AND PROVIDE MILLWORK TRIM AND INFILL PANELS AT
UNDERCOUNTER / CABINET LOCATIONS.
7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION.
8. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
9. DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, AND
FACE OF METAL STUD, UNLESS NOTED OTHERWISE.
10. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED
OTHERWISE.
11. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND
HALF TONE.
12. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO
SHEETS A-603 AND A-604.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:5
A
M
A-103
A
IR
O P S F
LO
O R P
LA
N F
IR
S T F
LO
O R A R E A C
LES
12801457
RJM RJM
1596300
1/8" = 1'-0" A1
AIR OPS - FLOOR PLAN - FIRST FLOOR - AREA C
PLAN
NORTH
4' 8' 16'0'
PLAN
NORTH
KEY PLAN
A
B
C
GENERAL NOTES
LEGEND
RECESSED WALK OFF MAT
WORK NOTES
EQ03 COMMERICAL WASHER (BASIS OF DESIGN TRISTATE LAUNDRY
EQUIPMENT MODEL #EXSM765)
EQ04 COMMERICAL DRYER (BASIS OF DESIGN TRISTATE LAUNDRY
EQUIPMENT MODEL #TD83); DRYER IS REQUIRED TO BE CAPABLE OF
EXHAUSTING THRU (2) 90 DEGREE ELBOWS AND 30 LINEAR FT OF 8"
DUCTWORK WITHOUT A BOOSTER FAN
PL05 ELECTRIC WATER COOLER, BI-LEVEL WITH BOTTLE FILLER, RE: PLUMB
DWGS
PN01 GUTTER / DOWNSPOUT
PN28 METAL WIRE WINDOW SCREEN
PN30 3 TIER LOCKERS
PN31 HDPE ADA BENCH WITH BACK SUPPORT, 20" DEEP (SEE B1/A-582)
PN35 HDPE BENCH, 20" DEEP (SEE B1/A-582)
PN36 BUILDING SIGNAGE, SEE B3/A-590 FOR DETAILS
RO11 PRE-MANUFACTURED METAL CANOPY; CENTER ON DOOR BELOW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
B1
A-201
A1
A-201
A1
A-202
C
B
ELEVATOR
CHIEF
MGYSGT
OSPO
CONFERENCE ROOM
WOMEN'S
NAVAIR EASU
FOD CELL
AOPS
JAN
211COMM
STAIR
RECEPTION
CORRIDOR
STORAGE
ATCO
OPEN TO
BELOW
S
K
/4
3/ 4"
24' - 0" 14' - 0"
1' - 1 1/4"
8' - 0"
1' - 1 1/4"
1'
1/
4"
8'
0"
1'
1/
4"
26' - 2 3/4"
/4
9'
1/
4"
26' - 4 1/2" 9' - 2 1/2"
MEN'S
STAIR
DN
DN
DN
DN
4' - 2 3/4"
M.O.
4' - 0" 6' - 0"
M.O.
4' - 0" 6' - 0"
M.O.
4' - 0" 6' - 0"
M.O.
8' - 0" 4' - 4 1/2" 10' - 1 1/2"
3'
3"
M .O
4'
0" 5'
4"
M .O
4'
0" 6'
0"
M .O
4'
0" 5'
4"
M .O
4'
0" 5'
4"
M .O
4'
0"
1'
1/
4"
/4
2'
- 4
1/ 2"
0"
2'
- 7
1/ 2"
E Q
E Q
E Q
E Q
EQ EQ
EQ EQ
A1 A-301
C1 A-301
RO02
RO01
VALLEY
VA
LLE
Y
VALL
EY
VALL
EY
RIDGE
R
ID
G E
RO07
RO02
RO03
RO07
RO02
RO09
CW7
CW6
CW7
W4W3W3W3
W6
W6
W6
W6
W3
W3
W3
W3
W3
RO07
RO07
KITCHEN
210A
F
J
H
7 8 11 14
RO11
RO11
RO01
C4 A-522
9 12 15
A
E
L
RO09
C3 A-545
SLOPE
2" / 12"
SLOPE
2" / 12"
SLOPE
1" / 12"
S
LO
P E
2"
S
LO
P E
2"
EQUIP. CLOSET
201A
PN34
RO12
RO12
/8
/8 " 6" 18' - 4 1/2"
RO17
RO17
C3 A-301
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:0
A
M
A-104
A
IR
O P S F
LO
O R P
LA
N S E C O N D F
LO
O R O V E R A
LL
LES
12801458
RJM RJM
1596300
3/32" = 1'-0" A1
AIR OPS - FLOOR PLAN - SECOND FLOOR - OVERALL
PLAN
NORTH
0' 8' 16' 32'4'
PLAN
NORTH
KEY PLAN
A
B
C
WORK NOTES
PN34 42" H GALV. STEEL GUARDRAIL WITH INFILL PANELS ON ALL SIDES OF
PARAPET. SEE C4/A-522 FOR DETAIL
RO01 PREFINISHED STANDING SEAM METAL ROOF ON R-30 INSULATION OVER
VAPOR BARRIER ON STRUCTURAL METAL DECK
RO02 PREFINISHED METAL GUTTER
RO03 PREFINISHED METAL DOWNSPOUT
RO07 TWO ROWS OF SNOW/ICE GUARDS
RO09 EXTERIOR ROOF ACCESS LADDER. REFER TO DETAIL A3/A-546
RO11 PRE-MANUFACTURED METAL CANOPY; CENTER ON DOOR BELOW
RO12 PREFINISHED METAL SCUPPER COLLECTOR BOX
RO17 ROOF TIE-DOWN FIXED ANCHOR BY ROOFING CONTRACTOR
GENERAL NOTES
LEGEND
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS ALL DOOR OPENINGS.
3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO
PARTITION TYPES SHEET A-501.
4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.
6. CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK TRIM
AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET LOCATIONS.
7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION.
8. PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN
WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR AND
WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP MOUNTING
SUPPORTS.
9. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
10. ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,
FACE OF METAL STUD, AND FACE OF PRECAST CONCRETE WALL PANEL,
UNLESS NOTED OTHERWISE.
11. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED
OTHERWISE.
12. FOR LOCKERS AND LOCKER BENCHES. PROVIDE BLOCKING AS
REQUIRED.
13. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED
MARKERBOARDS, TACKBOARDS, STORAGE UNITS, OR AV EQUIPMENT,
INCLUDING FLAT PANEL DISPLAYS. REFERENCE FURNITURE PLANS FOR
LOCATIONS OF WALL ACCESSORIES, MARKER BOARDS AND VISUAL
DISPLAY EQUIPMENT.
14. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND
HALFTONED.
15. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO
SHEET A-603 AND A-604.
RAF - RAISED ACCESS FLOOR
(18" HIGH) TYPE AF-1
ROOF PAVERS ON PEDESTALS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
ELEVATOR
CHIEF
MGYSGT
OSPO
CONFERENCE ROOM
WOMEN'S
NAVAIR EASU
FOD CELL
AOPS
C
B
JAN
COMM
STAIR
RECEPTION
CORRIDOR
STORAGE
ATCO
218 21
0B
210A
OPEN TO
BELOW
S
K
MEN'S
STAIR
9'
3/
4"
3/
4" 9'
8"
9'
7"
0C
14' - 6" 6' - 6" 9' - 0" 6' - 0 1/4"
/2 " 6'
0"
6'
6"
12' - 8" 16' - 0" 16' - 3 3/4"
5'
3/
4"
5' - 6 3/4"
12' - 0 1/4"
9'
3/
4"
A-403 C4
A-401 A3
A-404 A2
A-403 A3
S2DA
S2DA
S2DA
S2DA S4DA
S4DA
S4DA
S2DA
S2DA S2DA
S2DA
S4DD
S4DD
H3ED H3ED
210D
WALL PROTECTION, TYP
S2DA
DN
DN
DN
DN
F1CA
F1CA
F1CA
F1CA
F1CA F1CA F1CA
F1CA
F1CA
F1CA
F1BA
F1BA
F1BA
F1BA
F1BA
F1BA
F1BAF1BA
F1BA
S4FA
S4DA
3' - 6"
2' - 0"
9' - 11"
KITCHEN
210A
S4DA
S4DA
S4DA
H3ED
H3ED
F
J
H
7 8 11 14
EQUIP. CLOSET
201A
1A
C
EN
TER
R
AF
EQ
C
EN
TER
R
AF
EQ
C
EN
TER
R
AF
EQ
C
EN
TER
R
AF
EQ
S2DA
S2DA
F1CA
S2DA
S2DA
4' - 7 3/4"
S2DA
A-561
C3
9 12
E
L
5 6
9"
9"
2'
4"
C2
A-505 PN29
PN32
S2DA
PN03
PN01
PN01
PN01
PN01
PN01
PN01
PN01
PN01
PN01 PN01
RO13
S1DB
W6
W6
W6
W6
W3
W3
W3
W3
W3
W3 W3 W3 W4
RO12
RO12
A-105 A3
PN19
A-511 B4
A-511 C1
A-511 C2
A-511 C3
A-545 A4
C3 A-301
A-545 A5
S4DD
A-511 B4
SIM
RO16
R
ID
G E
1/ 2"
/1 2"
S
LO
PE
1/ 2"
/1 2"
S
LO
PE
1/2"/12" SLOPE
/2
S L O
P E
VALLEY
V A
L L E
Y
C4 A-522
B2 A-522
SIM
RO12
RO12
CONFERENCE ROOM
D3 A-546
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:0
A
M
A-105
A
IR
O P S F
LO
O R P
LA
N S E C O N D F
LO
O R A R E A A
LES
12801459
RJM RJM
1596300
1/8" = 1'-0" A1
AIR OPS - FLOOR PLAN - SECOND FLOOR - AREA A
PLAN
NORTH
4' 8' 16'0' PLAN
NORTH
KEY PLAN
A
B
C
GENERAL NOTES
LEGEND
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS ALL DOOR OPENINGS.
3. FOR PARTITION TYPES, CONSTRUCTION, AND DESCRIPTION, REFER TO
PARTITION TYPES SHEET A-501.
4. FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
5. DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO OUTSIDE EDGE OF DOOR FRAME.
6. CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK TRIM
AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET LOCATIONS.
7. REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION.
8. PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN
WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR AND
WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP MOUNTING
SUPPORTS.
9. REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
10. ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,
FACE OF METAL STUD, AND FACE OF PRECAST CONCRETE WALL PANEL,
UNLESS NOTED OTHERWISE.
11. THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS NOTED
OTHERWISE.
12. FOR LOCKERS AND LOCKER BENCHES. PROVIDE BLOCKING AS
REQUIRED.
13. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED
MARKERBOARDS, TACKBOARDS, STORAGE UNITS, OR AV EQUIPMENT,
INCLUDING FLAT PANEL DISPLAYS. REFERENCE FURNITURE PLANS FOR
LOCATIONS OF WALL ACCESSORIES, MARKER BOARDS AND VISUAL
DISPLAY EQUIPMENT.
14. REFERENCE FURNITURE PLANS FOR EQUIPMENT SHOWN DASHED AND
HALFTONED.
15. FOR DOOR, WINDOW, AND CURTAIN WALL SCHEDULES, REFER TO
SHEET A-603 AND A-604.
RAF - RAISED ACCESS FLOOR
(18" HIGH)
LEVELING PAVERS ON PEDESTALS
WORK NOTES
PN01 GUTTER / DOWNSPOUT
PN03 MECHANICAL CHASE
PN19 MOP SHELF
PN29 ALUMINUM GUARDRAIL AND SHOE MOULDING WITH TEMPERED GLASS
INFILL PANELS (3 SIDES OF OPENING), SEE C2/A-505 FOR DETAIL
PN32 SIDE COILING FIRE AND SMOKE RATED DOOR
RO12 PREFINISHED METAL SCUPPER COLLECTOR BOX
RO13 EXTERIOR ROOF ACCESS LADDER, REFER: DETAIL A3/A-531
RO16 MODIFIED BITUMINOUS MEMBRANE ROOFING ON PROTECTION BOARD
AND RIGID INSULATION (R-30)
1/8" = 1'-0" A3
PLAN DETAIL - PATIO ROOF (BELOW PAVERS)
PLAN
NORTH
4' 8' 16'0'
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
B1
A-201
A1
A-201
A1
A-202
B
S
25' - 8" 14' - 4"
9'
1/
4"
26' - 2 1/4" 9' - 4 3/4"
/4
/4
26' - 5 3/4" 70' - 10 1/4"
8 3 /4"
0"
A1 A-301
RO02
RO01
RIDGE
R
ID
G E
VALLEY
VALLEY
VALLEY
ROOF PERIMETER BELOW
ROOF PERIMETER BELOW
RO07
RO07
RO09
ROOF PERIMETER
BELOW
0"
/2
1/2" / 12"
1/ 2"
1/
2"
RO02
RO01
RO07
RO07
RO02
RO01
RO02
RO07
RO02
A2 A-522
B2 A-522
RO12
SLOPE
2" / 12"
SLOPE
2" / 12"
S
LO
P E
2"
S
LO
P E
2"
SLOPE
1" / 12"
RO16
RO02
RO02
C3 A-301
A-511 C4
10' - 3 3/4"
/4
A1 A-522
ROOF AREA KEY PLAN
B
C
D
A
G
F
E
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:1
A
M
A-106
A
IR
O P S R O O F P
LA
N
LES
12801460
RJM RJM
1596300
3/32" = 1'-0" A1
AIR OPS - ROOF PLAN
WORK NOTES
RO01 PREFINISHED STANDING SEAM METAL ROOF ON R-30 INSULATION OVER
VAPOR BARRIER ON STRUCTURAL METAL DECK
RO02 PREFINISHED METAL GUTTER
RO07 TWO ROWS OF SNOW/ICE GUARDS
RO09 EXTERIOR ROOF ACCESS LADDER. REFER TO DETAIL A3/A-546
RO12 PREFINISHED METAL SCUPPER COLLECTOR BOX
RO16 MODIFIED BITUMINOUS MEMBRANE ROOFING ON PROTECTION BOARD AND
RIGID INSULATION (R-30)
PLAN
NORTH
0' 8' 16' 32'4'
PLAN
NORTH
KEY PLAN
A
B
C
ROOF DRAINAGE CALCULATIONS
ROOF
AREA SLOPE
AREA
(SF)
ADDED
ROOF
AREA
(SF)
PITCH
FACTOR
(SMACNA
TABLE 1-1)
DESIGN
AREA
(SF)
DOWNSPOUT
QTY
DS
AREA/290*
PER 100 YR
MINIMUM
DOWNSPOUT
SIZE (IN)
DOWNSPOU
T PROVIDED
(IN)
RAINFALL
INTENSITY IA
MAX
GUTTER
LENGTH
(FT)
MINIMUM
GUTTER
DIMENSION
(IN)
PROVIDED
GUTTER
WIDTH X
DEPTH
A 2/12 1,386 0 1.00 1,386 2 2.39 1.75 W X 2.25 D 3 W X 4 D 4.1 2,841 28 4 X 4 6 X 6
B 1/2 / 12 510 0 1.00 510 2 0.88 1.75 W X 2.25 D 3 W X 4 D 4.1 1,046 44 3 X 3 6 X 6
C 2/12 1,360 0 1.00 1,360 2 2.34 1.75 W X 2.25 D 3 W X 4 D 4.1 2,788 29 4 X 4 6 X 6
D 2/12 2,898 0 1.00 2,898 6 1.67 1.75 W X 2.25 D 3 W X 4 D 4.1 1,980 33 4 X 4 6 X 6
E 2/12 3,364 54 1.00 3,418 3 3.93 1.75 W X 2.25 D 3 W X 4 D 4.1 4,671 48 5 X 5 6 X 6
F 2/12 7,711 2,898 1.00 10,609 6 6.10 3 W X 4 D 3 W X 4 D 4.1 7,249 46 6 X 6 6 X 6
G 2/12 2,023 54 1.00 2,077 2 3.58 1.75 W X 2.25 D 3 W X 4 D 4.1 4,258 31 5 X 5 6 X 6
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
R
I
C
B
MEN'S
WOMEN'S
BUNK ROOM
BUNK ROOM
WX SUPERVISOR
WX SNCOIC
WX OIC
ELEVATOR
ELEV EQUIP
STAIR
FLIGHT PLANNING ROOM
BUNK ROOM
BUNK / LOCKER
F/C SNCOIC
F/C CIV
ODO
STAIR
JANITOR
TOILET / SHOWER
CORRIDOR
CORRIDOR
VESTIBULE
COMM
ENTRY
F/C
WX FLOOR
QUIET
ADMIN STOR
MOTHERS RM
ASOS
WX SIPR
9' - 0" A.F.F.
10' - 0" A.F.F.
OPEN TO
ABOVE
10' - 0" A.F.F.
S
K
D
8' - 0" A.F.F.
8' - 0" A.F.F.
8' - 0" A.F.F.
TOILET / SHOWER
8' - 0" A.F.F.
8' - 0" A.F.F.
S E
E A
-1
F O
R A
R E
A C
A R
E A
A
SEE A-108 FOR AREA B
AREA A
A1 A-301
10' - 0" A.F.F.
8' - 0" A.F.F.
8' - 0" A.F.F.
Q
P
N
M
F
G
J
H
3 4 7 8 11 13 149 12
E
L
5 6
2' - 4"
2' - 4"
2'
A
LI
G N
ALIGN
8' - 8 5/8"
135.00°
8' /8
.0
135.00°
.0
2' - 4"2' - 4"
B1 A-551
B1 A-551
A3 A-551
E Q
E Q
A3 A-551
SIM
1"
ME02ME02
ME02
ME02
ME02
ME02
C3 A-301
B4 A-551
B4 A-551
EQ EQ
T Y P O F
7'
3'
3' - 8"
TYP OF 4
7' - 0"
10' - 0" A.F.F.
9' - 0" A.F.F.
ACT-1: 2' x 2' ACOUSTICAL
CEILING TILE
GYPSUM BOARD - PAINT
RECESSED LIGHT
10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR
HVAC AIR SUPPLY GRILLE
HVAC EXHAUST OR RETURN GRILLE
EXIT SIGN
1' x 4' FIXTURE - SUSPENDED
2' x 4' FIXTURE - RECESSED
2' x 2' FIXTURE - RECESSED
EXPOSED CEILING; PAINT STRUCTURE
AND ROOF DECK ABOVE
4' FIXTURES - MULLION/WALL MOUNTED
MULLION LIGHTS
CEILING MATERIAL LEGEND
HVAC LINEAR SUPPLY DIFFUSER
ACCESS HATCH (12" X 12" OR 24" X 24")
EMERGENCY LIGHT FIXTURE - WALL MOUNTED
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
EJA
M C
A S
C H
E R
R Y
P O
IN
T
C H
E R
R Y
P O
IN
T
N
C
AS NOTED
1317 EXECUTIVE BLVD.
SUITE 300
CHESAPEAKE, VA 23320
F Y P -2 A T C T O W E R A N D A
IR
O P E R A T
IO
N S
DRAWFORM REVISION: 12 APRIL 2018
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
FI
LE
N A
M E
P
LO
TT
E D
CJC/KDB
CGM
DSN
SAT-TO FORM SIGNED BY
DON ELLIOT 12/19/19
C
R e v it P ro je c ts
\B L D
G -P
-1
-A
-O P
S -C e n tr a l_
C to sl o s ki e b u rn sm c d .c o m
.r v t
/1
/2
:1
:1
A
M
A-107
A
IR
O P S R E F
LE
C
TE
D C E
IL
IN
G P
LA
N F
IR
S T F
LO
O R A R E A A
LES
12801461
RJM RJM
1596300
1/8" = 1'-0" A1
AIR OPS - REFLECTED CEILING PLAN - FIRST FLOOR - AREA A
PLAN
NORTH
KEY PLAN
A
B
C
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. ARCHITECTURAL CEILING PLANS INDICATE DIMENSIONING AND
PLACEMENT OF VARIOUS CEILING MOUNTED DEVICES. REFER TO MEP
DRAWINGS AND SPECIFICATIONS FOR OTHER INFORMATION FOR MEP
SYSTEMS INCLUDING BUT NOT LIMITED TO FIRE SUPPRESSION, FIRE
ALARM DEVICES, SECURITY DEVICES, EXIT DEVICES, DIFFUSERS,
LIGHTING, LIGHTING CONTROL DEVICES, AND ACCESS PANELS.
3. CEILING HEIGHTS ARE SHOWN TO HEIGHT ABOVE FINISH FLOOR.
4. CENTER CEILING GRIDS IN ROOMS UNLESS NOTED OTHERWISE.
5. CENTER LIGHTS, SPEAKERS, SPRINKLERS, SIGNAGE, STROBES AND
OTHER HARDWARE INSTALLED IN TILED CEILING SYSTEMS IN TILES IN
BOTH DIRECTIONS UNLESS NOTED OTHERWISE.
6. REFERENCE ROOM FINISH SCHEDULE FOR ADDITIONAL CEILING FINISH
INFORMATION.
7. CENTER CEILING MOUNTED EXIT SIGNS WITHIN DOOR FRAME OR
OPENING. MOUNT 4" OFF FACE OF WALL.
8. ALIGN SPRINKLERS, JUNCTION BOXES & SMOKE DETECTORS WITH
ADJACENT LIGHT FIXTURES, UNLESS NOTED OTHERWISE.
9. COORDINATE LOCATIONS OF CEILING ACCESS PANELS WITH THE
FINAL LOCATIONS OF MECHANICAL EQUIPMENT AS REQUIRED TO
SERVICE EQUIPMENT AND TO PROVIDE ACCESS TO ABOVE CEILING
EQUIPMENT.
10. AT CONTINUOUS RUNS OF GYPSUM BOARD ASSEMBLIES, PROVIDE
CONTROL JOINTS AT A MAXIMUM OF (1) PER 50 FEET, NOT TO EXCEED
INDIVIDUAL AREAS OF 2,500 SQUARE FEET. SEE D4 ON SHEET A-553.
11. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT SOFFITS AND
CEILINGS OF RESTROOMS, LOCKER ROOMS, SHOWERS AND OTHER
WET AREAS.
12. CEILINGS ARE 9'-0 ABOVE FINISH FLOOR, UNLESS OTHERWISE NOTED.
PLAN
NORTH
4' 8' 16'0'
GENERAL REFLECTED CEILING PLAN
NOTES
WORK NOTES
ME02 ACCESS PANEL; COORDINATE WITH MECH. DAMPERS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R B
ID
/1 8/
PIR
HSS
C
B
ELEC
MECHANICAL
BASH
WX CLASSROOM
AIRFIELD LIGHTS
CORRIDOR
COMM
BASE NODE
MOTHERS RM
WEAPON STOR
110 UPS
D
SEE A-107 FOR AREA A
AREA B
C1 A-301
3 4 7 8 119 12
A
5 6
TOILET / SHOWER
STAIR
WX OIC
MEN'S
WOMEN'S
C3 A-301
B1 A-551
A3 A-551
3'
6"
3' - 6"
ACT-1: 2' x 2' ACOUSTICAL
CEILING TILE
GYPSUM BOARD - PAINT
RECESSED LIGHT
10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR
HVAC AIR SUPPLY GRILLE
HVAC EXHAUST OR RETURN GRILLE
EXIT SIGN
1' x 4' FIXTURE - SUSPENDED
2' x 4' FIXTURE - RECESSED
2' x 2' FIXTURE - RECESSED
EXPOSED CEILING; PAINT STRUCTURE
AND ROOF DECK ABOVE
4' FIXTURES - MULLION/WALL MOUNTED
MULLION LIGHTS
CEILING MATERIAL LEGEND
HVAC LINEAR SUPPLY DIFFUSER
ACCESS HATCH (12" X 12" OR 24" X 24")
EMERGENCY LIGHT FIXTURE - WALL MOUNTED
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G C O M M A N D M
ID
-A T L A N T
IC
M A
R
IN
E C
O R
P S
I P
T N
A V
A L
S T
A T
IO
N
N
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .