1596300_dwg_28of35_V3_Equipment.pdf

PDF 14 MB Posted

Attached to
Design Bid-Build P228 ATC Tower and Air Operations, Marine Corps Air Station, Cherry Point, North Carolina
Solicitation number
N4008522R2504
Issued by

View the file

Other files

File Type Posted
AMEND 0010 UPDATED WAGE DETERMINATION FOR P228.pdf PDF
AMENDMENT 0011 FOR P228 ATC TOWER.pdf PDF
AMENDMENT 0009.pdf PDF
Amendment 0008.pdf PDF
AMENDMENT 0007 FOR P228.pdf PDF
UPDATED REVISED BID SCHEDULE FOR P228.pdf PDF
AMENDMENT 0006 FOR P228.pdf PDF
PPI LOG 04 FOR P228.pdf PDF
AMENDMENT 0005 FOR P228.pdf PDF
UPDATED BID SCHEDULE FOR P228.pdf PDF
P228 PPI LOG 03.pdf PDF
P228 AMENDMENT 0004.pdf PDF
PPI LOG 02 FOR P228.pdf PDF
P228 AMENDMENT 0003.pdf PDF
P228 AMENDMENT 0003 DOCUMENT FOR PPI 4-7.pdf PDF
P228 AMENDMENT 0002.pdf PDF
AMENDMENT 0002-DRAWING REFERENCES.pdf PDF
P228 PPI LOG 01.pdf PDF
AMENDMENT 0001 FOR P228.pdf PDF
Site Visit Log P228.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
1596300_dwg_24of35_V2_Architectural.pdf PDF
1596300_dwg_16of35_V1_Civil.pdf PDF
1596300_dwg_05of35_V1_Civil.pdf PDF
1596300_dwg_14of35_V1_Civil.pdf PDF
1596300_dwg_33of35_V4_Electrical.pdf PDF
1596300_dwg_12of35_V1_Civil.pdf PDF
1596300_dwg_06of35_V1_Civil.pdf PDF
1596300_dwg_21of35_V1_Landscape.pdf PDF
RFP FOR P228 ATC TOWER.pdf PDF
1596300_dwg_23of35_V2_Structural.pdf PDF
1596300_dwg_01of35_V1_General.pdf PDF
1596300_dwg_22of35_V2_General.pdf PDF
Attachment A - Pre-Propsal Injuiries Log.doc DOC document
1596300_dwg_17of35_V1_Civil.pdf PDF
1596300_dwg_09of35_V1_Civil.pdf PDF
1596300_dwg_15of35_V1_Civil.pdf PDF
Attachment E - Historical Small Business Utilization.docx DOCX document
1596300_dwg_04of35_V1_Survey-Geotechnical.pdf PDF
1596300_dwg_34of35_V4_Telecommunications.pdf PDF
1596300_dwg_26of35_V2_Interiors.pdf PDF
USCG MULTI-USE COMPLEX - 00 01 15 LIST OF DRAWINGS 100422.pdf PDF
Attachment F - Small Business Participation Commitment Document.docx DOCX document
ATTACHMENT B BID SCHEDULE FOR P228 ATC TOWER.pdf PDF
JA ML-23-07 CHPT P228 Fire Protection_Redacted.pdf PDF
Attachment H- PIEE Vendor Access Instructions.pdf PDF
1596300_dwg_35of35_V4_Telecommunications.pdf PDF
1596300_dwg_11of35_V1_Civil.pdf PDF
1596300_dwg_27of35_V3_General.pdf PDF
1596300_spc01of01.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M4

W12

HSS7x3

HSS7x3

H

S

S x

HSS6x3

HSS7x3

INSIDE

OUTSIDE

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

QG001

INSIDE OF MULLION - (2) 2" FLEX CONDUITS REQUIRED AT M3, M4, M6, M8

(2) 1" FLEX CONDUITS REQUIRED AT M5, M7, M9, M10

INSIDE OF MULLION

CAP AT M1, M2,

AND M10

EXTERIOR OF MULLION - 1" PVC CONDUIT REQUIRED AT M2, M4, M7, M9

M U

L L

I O

N

A

C C

E S

S

H

O L

E

L

O C

A T

I O

N

P

L A

N

S

C H

E D

U L

E

A N

D

F

I R

E

P

R O

O F

I N

G

D

E T

A I L

S

M8

M7

M6

M5

M4

M3

M2

M9

M10

M1

" UNISTRUT

AT MULLION

M1, M2, AND M10

.050 DARK BRONZE

ALUMINUM MULLION

CAP TRIM

TUBE COLUMNS SHALL

BE FIRE PROOFED

PER UL DESIGN X630 2 HR

OR APPROVED EQUAL

CABLE OR POWER

ACCESS HOLE LOCATIONS

TYP ALL COLUMNS

AS INDICATED

PERIMETER ROOF

BEAM FIRE

PROOFING SHALL BE

UL DESIGN X632

2HR, OR

APPROVED EQUAL

2 HR TRUSS

FIRE PROOFING

ROOF ASSEMBLY

FIRE PROOFING SHALL

BE UL DESIGN X632

OR APPROVED EQUAL

2 HR FIRE PROOFING

@ CABLE ACCESS

HOLE LOCATIONS

2 HR FIRE PROOFING

@ CABLE ACCESS

HOLE LOCATIONS

H

R

F

I R

E

P

R O

O F

I N

G

S

T R

U C

T U

R E

F I R

E

P

R O

O F

I

O

R

E Q

U I R

E D

SCALE: 3/8" = 1'-0"

A3

MULLION ACCESS HOLE

LOCATION PLAN

N

0 2' 4' 6'

SCALE: 3" = 1'-0"

C1

TYP UTILITY LOCATION DETAIL

AT MULLION

SCALE: 1/2" = 1'-0"

B5

TYP CAB STRUCTURE FIRE

PROOFING DETAIL

2 HR FIRE CAULK REQUIRED AT ALL ACCESS

HOLE LOCATIONS - SEE PLAN FOR LOCATIONS

UTILITY MULLION SCHEDULE:

No. DESCRIPTION LOCATION

M1 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M1 POWER TO ROOF INSIDE OF MULLION

M2 SPRINKLER TO ABOVE CEILING INSIDE OF MULLION CAP

M3 LIGHTNING GROUNDING EXTERIOR OF MULLION

M3 COMMUNICATION TO ROOF INSIDE OF MULLION

M4 POWER TO ABOVE CEILING INSIDE OF MULLION

M4 LIGHTNING GROUNDING EXTERIOR OF MULLION

M4 COMMUNICATION TO ROOF INSIDE OF MULLION

M5 RADAR DISPLAY CONTROL WIRE INSIDE OF MULLION

M5 POWER TO ABOVE CEILING INSIDE OF MULLION

M6 COMMUNICATION TO ROOF INSIDE OF MULLION

M7 POWER TO ABOVE CEILING INSIDE OF MULLION

M7 LIGHTNING GROUNDING EXTERIOR OF MULLION

M8 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 POWER TO ABOVE CEILING INSIDE OF MULLION

M9 LIGHTNING GROUNDING EXTERIOR OF MULLION

M9 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 PLUMBING VENT INSIDE OF MULLION CAP

M10 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M10 FIRE ALARM TO ABOVE CEILING INSIDE MULLION

M10 LIGHTING GROUNDING EXTERIOR OF MULLION

0 2' 4'

0 4" 8"

8/

/2

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

JAS

STRUCTURAL WORK SHALL BE IN ACCORDANCE WITH "UFC 3-301-01", "STRUCTURAL

ENGINEERING" WITH CHANGE 4, AND INTERNATIONAL BUILDING CODE 2018 EDITION, AS ADOPTED

AND SUPPLEMENTED BY LOCAL REGULATIONS.

VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO STARTING CONSTRUCTION. NOTIFY

THE ENGINEER OF ANY DISCREPANCIES OR INCONSISTENCIES.

DO NOT SCALE DRAWINGS TO OBTAIN ACTUAL DIMENSIONS.

SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR MISCELLANEOUS ITEMS

NOT SHOWN ON THE CAB STRUCTURAL DRAWINGS.

SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ANCHORED, SUPPORTED

AND EMBEDDED ITEMS WHICH AFFECT THE STRUCTURAL WORK. VERIFY DETAILS, LOCATION, AND

DIMENSIONS WITH EQUIPMENT PURCHASED.

COORDINATE OPENING SIZES AND FRAMING SHOWN ON DRAWING, COORDINATE OPENING

LOCATIONS IN FLOORS, WALLS, AND ROOF WITH ARCHITECTURAL, MECHANICAL ELECTRICAL AND

COMMUNICATIONS ETC. REQUIREMENTS.

ALL ELEVATIONS ARE REFERENCED TO DATUM ELEVATION 0'-0" (FINISH FIRST FLOOR), UNLESS

OTHERWISE NOTED. SEE SITE PLAN FOR ACTUAL ELEVATIONS.

NO CHANGES IN CONSTRUCTION FROM THAT SHOWN IN THE APPROVED SHOP DRAWINGS SHALL

BE MADE WITHOUT THE SPECIFIC WRITTEN APPROVAL OF THE ENGINEER.

ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL, UNLESS

SPECIFICALLY NOTED OTHERWISE, AND SHALL BE CONSTRUED TO APPLY TO ANY OTHER SIMILAR

SECTION OR LOCATION ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.

ANY VARIANCE FROM THE CONTRACT DOCUMENTS SHALL BE CLEARLY NOTED WITH A VARIANCE

REQUEST ON SHOP DRAWING SUBMITTALS.

ANY SUBMITTALS WITH INCOMPLETE RELATED INFORMATION MAY BE SUBJECT TO LATER

RESUBMITTALS.

CONTRACTOR SHALL MAINTAIN AS-BUILT DRAWINGS ON SITE INDICATING MODIFICATIONS

PERFORMED IN THE FIELD.

THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE,

WORK PERSONS AND OTHER PEOPLE DURING CONSTRUCTION. THE CONTRACTOR SHALL

SUPERVISE AND DIRECT THE WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION.

PHOTOGRAPHIC REPRODUCTION OF THE CONTRACT DOCUMENTS IN THE PREPARATION OF SHOP

DRAWINGS WILL NOT BE ALLOWED.

GENERAL:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

20 psf (PER UFC 3-301-01)

DESIGN DATA:

LIVE LOADS:3.

ROOF

5.

1. ULTIMATE DESIGN WIND SPEED: V = 153 mph

NOMINAL DESIGN WIND SPEED: V = 119 mph

2. RISK CATEGORY; 'IV'

3. EXPOSURE 'CATEGORY 'C'

- IBC 2018 EDITION

WIND DESIGN DATA (per ASCE 7-10)

Is. = 1.2

Pg = 10 psfGROUND SNOW LOAD

SNOW LOAD:4.

IMPORTANCE FACTOR

ROOF SNOW LOAD Pf = 15 psf

ULT

ASD

4. INTERNAL PRESSURE COEFFICIENT, GCpi = ±0.18, 'ENCLOSED' BUILDING

5. SEE SCHEDULES & DIAGRAMS FOR COMPONENT AND CLADDING PRESSURES.

6. ALL COMPONENT AND CLADDING PRESSURES ARE NOMINAL 'ASD' PRESSURES.

NO FURTHER 0.6 REDUCTION FACTORS ARE ALLOWED.

ROOF LEVEL 25 psf

DEAD LOADS (INCLUDES STRUCTURE)2.

7. ALL BUILDING ELEMENTS EXPOSED TO THE WIND SHALL BE DESIGNED FOR

COMPONENT & CLADDING PRESSURES UNLESS 'EFFECTIVE AREA' > 600 sf, IN

ADDITION TO 'MAIN WIND FORCE RESISTING SYSTEM' (MWFRS) PRESSURES AND

SIMULTANEOUS 'MWFRS' GENERATED LOADS AS REQ'D.

1. RISK CATEGORY 'IV'

2. SEISMIC IMPORTANCE FACTOR: IE = 1.5

3. SS = 0.096 g, S1 = 0.048 g

4. SITE CLASS 'D'

5. SDS = 0.103 g, SD1 = 0.077 g

6. SEISMIC DESIGN CATEGORY: 'C'

7. BASIC SEISMIC FORCE-RESISTING STEEL SYSTEM: NOT SPECIFICALLY

DESIGNED FOR SEISMIC RESISTANCE

8. SEISMIC RESPONSE COEFFICIENT: CS = 0.06

9. RESPONSE MODIFICATION FACTOR: R = 3

10. SEISMIC BASE SHEAR: 6.3 kips (LRFD) BASE OF CAB COLUMNS

6.

EARTHQUAKE DESIGN DATA

- UFC 4-023-03 'DESIGN OF BUILDINGS TO RESIST PROGRESSIVE COLLAPSE' WITH

STRUCTURAL STEEL:

STEEL WORK SHALL CONFORM TO ANSI/AISC 360-16 'SPECIFICATION FOR STRUCTURAL

STEEL BUILDINGS', ANSI/AISC 341-16 'SEISMIC PROVISIONS FOR STRUCTURAL STEEL

BUILDINGS', AND ANSI/AISC 303-16 'CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS

AND BRIDGES.'

- DESIGN OF CAB STRUCTURE BASED ON 'LOAD RESISTANCE FACTOR DESIGN' ('LRFD')

MATERIAL SHALL CONFORM TO THE FOLLOWING, U.O.N.:

WIDE FLANGE (W-SECTION) SHAPES: ASTM A992, GRADE 50, Fy = 50 ksi

HOLLOW STRUCTURAL SECTIONS: ASTM A500, GRADE C, Fy = 50 ksi

ANGELS, CHANNELS, PLATES: ASTM A36, Fy = 36 ksi

PIPE: ASTM A53, GRADE B, Fy = 35 ksi

HIGH STRENGTH BOLTS: ASTM A325, MIN 3/4" DIA

HARDENED STEEL WASHERS: ASTM F436

STEEL NUTS: ASTM A563

ANCHOR RODS: ASTM F1554, GRADE 55

REVIEW OF SHOP DRAWINGS DOES NOT INDICATE ACCEPTANCE OF DEVIATIONS FROM

THE CONTRACT DRAWINGS, EXCEPT WHEN SPECIFICALLY APPROVED BY THE ENGINEER

PRIOR TO SUBMISSION OF SHOP DRAWINGS. CONFLICTS ARISING FROM THIS WORK AND

THE WORK OF OTHER TRADES DUE TO SUCH DEVIATIONS, AND DIMENSIONAL CONFLICTS

AS A RESULT OF SUCH DEVIATIONS, SHALL BE DEEMED THE FABRICATORS

RESPONSIBILITY.

WELDED CONNECTIONS:

- ALL SHOP AND FIELD WELDING SHALL CONFORM TO AWS STRUCTURAL WELDING CODE

AWS D1.1 : 2015

- ELECTRODES FOR A36 & A992 STEEL SHALL BE E70XX. ELECTRODES FOR OTHER

MATERIALS ARE INDICATED ON TABLE 3.1, AWS 2000, 'BASE AND FILLER METAL

COMBINATIONS FOR MATCHING STRENGTH'

- MINIMUM SIZE FILLET WELDS, 3/16" EFFECTIVE THROAT.

THE FABRICATOR SHALL BE RESPONSIBLE FOR THE SELECTION, DESIGN AND DETAILING

OF ALL CONNECTIONS NOT FULLY DETAILED ON THE CONTRACT DRAWING. WHERE BEAM

REACTIONS ARE NOT SHOWN ON THE DRAWINGS, CONNECTIONS SHALL BE DETAILED FOR

THE MAXIMUM UNIFORM LOAD WHICH THE BEAM WILL SUPPORT (AS A SIMPLE BEAM) FOR

THE SPAN SHOWN ON THE DRAWINGS, OR A VERTICAL SHEAR OF 15 kips MIN. A MINIMUM

OF TWO (2) -3/4" DIAMETER A325 BOLTS SHALL BE USED FOR ALL ALL CONNECTORS

TYPICAL U.O.N. CONNECTION DESIGN SHALL BE IN ACCORDANCE WITH APPROVED AND

ESTABLISHED PRACTICE PER AISC'S STANDARD CONNECTION.

ALL BOLTS IN SLIP CRITICAL CONNECTIONS SHALL BE INSTALLED USING DIRECT TENSION

INDICATORS (DTI'S) MADE TO ASTM F959 LATEST REVISION. DTI'S SHALL BE INSTALLED AND

INSPECTED ON THE BOLTS PER THE MANUFACTURER'S INSTRUCTIONS AND

RECOMMENDATIONS, AND TO THE PROVISIONS CONTAINED IN THE RESEARCH COUNCIL

ON STRUCTURAL CONNECTIONS "SPECIFICATION FOR STRUCTURAL JOINTS USING A325

AND A490 BOLTS".

MODIFICATIONS TO DETAILS OF CONNECTIONS AND SPLICES ARE NOT PERMITTED

WITHOUT WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER. REFER TO

SPECIFICATION SECTION ON "STRUCTURAL STEEL" FOR FURTHER REQUIREMENTS

PERTAINING TO THE DESIGN OF CONNECTIONS.

SPLICING, NOTCHING, CUTTING OR OTHER ALTERATIONS TO STRUCTURAL STEEL NOT

SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS IS NOT PERMITTED WITHOUT

WRITTEN AUTHORIZATION FROM THE ARCHITECT/ENGINEER.

PROVIDE HOLES FOR THE SECURING OF WORK OF OTHER TRADES TO THE STRUCTURAL

STEEL AS SHOWN ON THE FINAL APPROVED SHOP DRAWINGS. CUT, DRILL OR PUNCH

HOLES PERPENDICULAR TO METAL SURFACES. DO NOT FLAME CUT OR ENLARGE HOLES

BY BURNING. DRILL HOLES IN BASE/BEARING PLATES.

FABRICATE BEAMS WITH RESIDUAL CAMBER UP.

ALL STRUCTURAL STEEL SHALL BE PREPARED AND PAINTED IN ACCORDANCE WITH STEEL

STRUCTURES PAINTING COUNCIL'S (SSPC) RECOMMENDATIONS. ALL STRUCTURAL STEEL

SHALL BE SHOP PRIMED IN RED OXIDE. UNLESS OTHERWISE NOTED ALL CONTACT AREAS

OF FRICTION TYPE CONNECTIONS SHALL BE MASKED OFF PRIOR TO PAINTING.

IMMEDIATELY AFTER ERECTION CLEAN ALL FIELD WELDS, ABRADED AREAS OF SHOP PAINT

AND BOLTED CONNECTIONS. APPLY TOUCH UP PAINT PAINT TO EXPOSED AREAS WITH

THE SAME MATERIALS AND MINIMUM THICKNESS USED FOR SHOP PAINTING. FOR METALS

TO BE PAINTED SEE PAINT SCHEDULE ON SHEET A-7 FOR PRIME COAT.

SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL MISCELLANEOUS STRUCTURAL STEEL

NOT SHOWN ON STRUCTURAL DRAWINGS.

ALL EXPOSED TUBE STEEL SHALL BE SEALED AT ENDS BY 3/16" MINIMUM THICK END

PLATES AND 3/16" CONTINUOUS FILLET/GROOVE WELDS MINIMUM SO THAT ALL TUBES ARE

COMPLETELY SEALED AGAINST MOISTURE INTRUSION. REFER TO DRAWINGS FOR

LOCATIONS WITH MORE STRINGENT REQT'S. GRIND WELDS SMOOTH AS REQ'D FOR

CONNECTIONS TYPICAL.

CONTRACTOR IS RESPONSIBLE FOR ERECTION OF ALL STEEL. ERECTION DRAWINGS

SHALL BE SUBMITTED FOR REVIEW & APPROVAL SHOWING ALL PREFABRICATED PIECES

AND PLANNED ERECTION SEQUENCE.

METAL DECK SHALL CONFORM TO STEEL DECK INSTITUTE (SDI) SDI-C-2017 'SPECIFICATION

FOR COMPOSITE STEEL FLOOR DECK', AND SDI-RC-2017 'SPECIFICATION FOR STEEL ROOF

DECK'. SUBMIT SHOP DRAWINGS OR APPROVAL BY ENGINEER, SHOWING FULL

COMPLIANCE WITH DIAPHRAGM AND NET UPLIFT LOAD REQUIREMENTS AS INDICATED ON

THE DRAWINGS.

METAL DECK SHALL BE AS FOLLOWS:

A) ROOF DECK; TYPE 'B'; 1.5B18, 18 GAGE, G90 GALVANIZED, (Fy = 33 ksi),t = 0..0474", Ip =

0.289 in^4, In = 0.295 in^4, Sp = 0.318 in^3, Sn = 0.327 in^3.

B) FLOOR DECK; TYPE 'C'; 0.6C, 26 GAGE, G90 GALVANIZED, (Fy = 33 ksi),t = 0.0179", Ip = 0.015 in^4, In = 0.015 in^4, Sp = 0.057 in^3, Sn = 0.057 in^3.

METAL DECK SHALL BE FASTENED TO ALL SUPPORTS AS FOLLOWS:

A) ROOF DECK; 5/8" PUDDLE WELDS IN A 36/4 PATTERN, WITH 3 #10 SIDE LAP FASTENERS

PER SPAN. AT ALL SUPPORTS, WELD SPACING SHALL NOT EXCEED 6", BOTH PARALLEL

AND PERPENDICULAR TO FLUTES. MINIMUM DIAPHRAGM LOAD = 287 plf (LRFD)

SIMULTANEOUS WITH UPLIFT LOADS OF 183 PSF (LRFD).

B) FLOOR DECK; #10 SCREWS IN A 30 / 4 PATTERN AND NO MORE THAN 12" O.C. AT ALL

EDCK EDGES, WITH 1-#10 AT ALL SIDELAPS.

DECKING SHALL BE CONTINUOUS OVER 3 SPANS MINIMUM WHERE SUPPORTING

STRUCTURE PERMITS. ROOF DECK TO SPAN NO LESS THAN TWO SPANS PER PANEL.

DECKING SHALL BE ERECTED IN STRICT ACCORDANCE WITH MANUFACTURERS

SPECIFICATIONS AND STEEL DECK INSTITUTE SPECIFICATIONS. COMPOSITE DECK SHALL

BE BUTT LAPPED AT SUPPORTS. ALL WELDING OF DECK SHALL BE IN ACCORDANCE WITH

AWS D1.3 STRUCTURAL WELDING CODE - SHEET STEEL.

METAL DECK:

FINISHED FLOOR

UNLESS OTHERWISE NOTED

SAW CUT JOINT

CONSTRUCTION JOINT

EXPANSION JOINT

DOWEL BAR ANCHOR

PRE-CAST CONCRETE INSTITUTE

WELDED WIRE REINFORCEMENT

TOP & BOTTOM

REINFORCED WITHR/W

U.O.N.

W/

TYP

TRANS

WWR

SJ

T & B

S.W.

SCH

SPECS

TYPICAL

TRANSVERSE

WITH

SCHEDULE

SHORT WAY

SPECIFICATIONS

F/F

L.W.

P/C

O.C.

PCI

P/S

L.P.

H.P.

FND

FTG

FS

LONG WAY

PRE-CAST

ON CENTER

PRE-STRESSED

LOW POINT

HIGH POINT

FOUNDATION

FOOTING

FAR SIDE

EF

EXP

EJ

EL

EW

DWG

EA

CJ

CONT

DBA

EACH FACE

EXPANSION

ELEVATION

EACH WAY

DRAWING

CONTINUOUS

EACH

STRUCTURAL ABBREVIATION LIST:

CLEAR/CLEARANCE

CENTER TO CENTER

AMERICAN CONCRETE INSTITUTE

AMERICAN INSTITUTE OF STEEL CONSTRUCTION

ACI

C/C

CL

CONC

CONN

COL

C

L

BLDG

BM

BLK

AISC

CENTER LINE

CONCRETE

CONNECTION

COLUMN

BUILDING

BLOCK

BEAM

NEAR SIDENS

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

1.

2.

3.

4.

5.

- UNITED FACILITIES CRITERIA (UFC) 4-133-01 WITH CHANGE 2 (2019) AIR TRAFFIC CONTROL AND

AIR OPERATIONS FACILITIES

- STRUCTURAL STEEL DESIGN PER ANSI/AISC 360-16 'SPECIFICATION FOR STRUCTURAL STEEL

BUILDINGS', ANSI/AISC 341-16 'SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS', AND

ANSI/AISC 303-16 'CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES.'

COLD FORMED METAL FRAMING - ELEVATED SLAB:

COLD FORMED FRAMING SHALL CONFORM TO:

- AISI S240-15 'NORTH AMERICAN STANDARD FOR COLD FORMED STEEL STRUCTURAL FRAMING'

- AISI S213 'NORTH AMERICAN STANDARD FOR COLD FORMED STEEL FRAMING'

- AISI S100-16 'NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED

STRUCTURAL STEEL MEMBERS'

- AISI S220-15 'NORTH AMERICAN STANDARD FOR COLD FORMED STEEL FRAMING - NON

STRUCTURAL MEMBERS'

- LATERAL DESIGN 2007 EDITION WITH SUPPLEMENT NO. 1

CONSTRUCT SYSTEM, INCLUDING CONNECTIONS, TO ACCOMMODATE CONSTRUCTION

TOLERANCES, DEFLECTION OF BUILDING STRUCTURAL MEMBERS AND CLEARANCES OF

INTENDED OPENINGS AND TOLERANCES AS REQ'D FOR ASSEMBLY. VERIFY THAT SUBSTRATE

SURFACES AND BUILDING FRAMING COMPONENTS ARE READY TO RECEIVE WORK PRIOR TO

START OF WORK.

JOISTS, STUDS, HEADERS, TRACKS AND CONNECTORS: ASTM A653 AND ASTM C955, G60 (ASTM

C 955) GALVANIZED, FORMED TO PROFILES, SHAPES, GAUGE AND NOMINAL SIZES AS

INDICATED. ALL MEMBERS SHALL BE INSTALLED PER ASTM C1007. ALL MEMBER SIZE

DESIGNATIONS ARE IN ACCORDANCE WITH SSMA STANDARDS.

MIN YIELD STRENGTH ARE AS FOLLOWS:

- MEMBERS AND SHAPES; 18 GA AND LIGHTER; 33 ksi.

- MEMBERS AND SHAPES; 16 GA AND HEAVIER; 50 ksi.

MAXIMUM VARIATION FROM TRUE POSITION: 1/4 INCH.

MAXIMUM VARIATION OF ANY MEMBER FROM PLANE: 1/4 INCH.

ATTACHMENTS/CONNECTIONS:

ALL MEMBERS AND ELEMENTS SHALL BE CONNECTED AS FOLLOWS: (ALL SCREWS ARE

#12-14, 2 POINT, TYPICAL, U.O.N.

- CR TRACK TO CONCRETE; POWDER ACTUATED, (0.145" DIA) @ 16" O.C., WITH 1 1/4" EMBED.

- VERTICAL STUDS TO TRACK; 2 SCREWS

- CR BRIDGING TO STUDS; L2x2x5x16 GA W/ 2-SCREWS

- STRAPS TO CR BRIDGING; 4-SCREWS

- STRAPS TO STUDS; 1-SCREW

SUBMIT SHOP DRAWINGS INDICATING COMPONENT DETAILS, FRAMED OPENINGS, ANCHORAGE,

TYPE AND LOCATION OF FASTENERS AND ACCESSORIES, ITEMS REQUIRED FOR OTHER

RELATED WORK OF OTHER TRADES. DRAWINGS SHALL BE FULLY COORDINATED WITH

ARCHITECTURAL AND THE WORK OF ALL OTHER TRADES AND INDICATE MEMBER LAYOUT,

INCLUDING FRAMING CONNECTIONS, OPENING FRAMING AND PROVISIONS FOR THE WORK OF

OTHER TRADES. PROVIDE PRODUCT DATA ON STANDARD FRAMING MEMBERS WITH MATERIALS

AND FINISH DESCRIPTION.

PROVIDE: RUNNERS, STUDS, JOISTS, BLOCKING, LINTELS, CLIP ANGLES, BRACING,

REINFORCEMENTS, STRAPS, FASTENERS AND ACCESORIES AS REQUIRED BY CALCULATIONS

AND/OR AS SHOWN ON DRAWINGS, AND AS A MINIMUM AS RECOMMENDED BY MANUFACTURER

FOR APPLICATIONS AND LOADS INDICATED, AND AS NEEDED TO PROVIDE A COMPLETE STEEL

FRAMING SYSTEM TO SUPPORT FINISHES.

TOUCH-UP FIELD WELDS AND DAMAGED SURFACES WITH COLD GALVANIZING PAINT.

ANY AND ALL SUBSTITUTIONS OF THINNER/SMALLER MEMBERS OR CONNECTIONS WILL

REQUIRE FULLY SIGNED AND SEALED DRAWINGS AND CALCULATIONS BY A STRUCTURAL

ENGINEER REGISTERED IN THE STATE THAT THE PROJECT IS LOCATED SHOWING THAT ALL

ELEMENTS OF SYSTEM COMPLY WITH ALL REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

CAB FLOOR 150 psf

- UFC 3-301-01 'STRUCTURAL ENGINEERING' WITH CHANGE 4 (2019)

1.

CHANGE 3 (2016)

QS001

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

F

T

H

A V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

I

S U

E D

F O

R B

ID

/1 8/

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

JAS

peted Text Box Sealed for all QS Drawings

SCALE: NONE

A1

COMPONENT AND CLADDING WIND ZONE DIAGRAMS

COMPONENT AND CLADDING ZONES WIND PRESSURES (PSF)

- TOTAL FORCE ON PARAPET COMPONENTS AND CLADDING

(FRONT & REAR VERTICAL PARAPET SURFACES COMBINED)

- FOR PRESSURES ON THE EXTERIOR PARAPET SURFACES

(ONLY) USE THE CORRESPONDING 'COMPONENT AND

CLADDING' WALL PRESSURES NOTED IN THE ABOVE TABLE.

- FOR INDIVIDUAL INTERIOR AND EXTERIOR PARAPET WALL

PRESSURES, SEE 'FIGURE 30.7-1' IN 'ASCE 7-16', AND USE

THE RESPECTIVE ROOF AND WALL PRESSURES AS NOTED

ABOVE.

WIND LOAD PARAMETER SUMMARY

- CODE: ASCE 7-16

- RISK CATEGORY; 'IV'

V_ult = 153 mph; qz_ult = 74.0 psf

V_nom = 119 mph; qz_asd = 44.4 psf

- EXPOSURE CATEGORY 'C'

- TYPE 'ENCLOSED',

GCpi = ±0.18

- MEAN ROOF HT = 195' (APPROX)

WIND LOAD PARAMETER SUMMARY

- ALL PRESSURES ARE 'NOMINAL'/'ASD' AND ALREADY INCLUDE AN 'ASD' LOAD FACTOR OF 0.6

WIND LOAD PRESSURE SCHEDULE - COMPONENTS & CLADDING (ASD, psf)

AREA 1 2 3 4 5

P+ve P-ve

0.0 -69.8 0.0 -109.6 0.0 -149.3 47.7 -47.7 47.7 -80.7

WIND LOAD PRESSURE SCHEDULE

COMPONENTS & CLADDING (ASD)

SPECIAL AREA ZONES (psf)

AREA (sf

P+ve P-ve

PARAPET

CORNER

154.1 192.9 -154.1 -233.3

ZONE 1

ZONE 3

ZONE 2

ZONE 5

ZONE 4

ZONE 5P

ZONE 4P

3'-0" FROM EACH

CORNER EDGE ZONE

ROOF PRESSURE PLAN CAB WALL ELEVATION

(sf) P+ve P-ve P+ve P-ve P+ve P-ve P+ve P-ve

0.0 -65.9 0.0 -104.1 0.0 -142.3 47.7 -47.7 47.7 -87.5

0.0 -60.7 0.0 -96.8 0.0 -133.0 43.9 -45.2 43.9 -77.4

0.0 -56.8 0.0 -91.4 0.0 -125.9 41.1 -43.3 41.1 -69.8

0.0 -52.9 0.0 -85.9 0.0 -118.9 38.2 -41.4 38.2 -62.2

0.0 -47.7 0.0 -78.6 0.0 -109.6 34.5 -38.9 34.5 -52.1

159.7 200.1 -159.7 -238.3

143.0 179.6 -144.2 -213.5

EDGE

P+ve P-ve

T

Y

P

Y

P

P A

R A

P E

T

C A

B

S

T R

U C

T U

R E

1.

INSULATED METAL PANEL:

INSULATED METAL PANELS SHALL BE SIZED AS FOLLOWS:

A) LOWER PANELS (ENCLOSED CAB) : 3" - 22/26 GA x 24" WIDE WITH VERTICAL JOINTS.

USE A MAXIMUM OF 30" WIDE PANELS.

B) UPPER PANELS (PARAPET): 2" - 22/26 GA, 'CUT' WITH VERTICAL JOINTS. USE A

MAXIMUM OF 30" WIDE PANELS.

INSULATED METAL PANELS SHALL MEET ALLOWABLE SPAN TABLES USING

'ASD' PRESSURES NOTED IN 'COMPONENT AND CLADDING' PRESSURES (TRIB AREA = 10

sf). NOTE THAT ALL PANELS THAT ARE CUT PARALLEL TO THEIR LENGTH.

INSULATED METAL PANELS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH WRITTEN

AND PUBLISHED RECOMMENDATIONS AND DETAILS.

INSULATED METAL PANELS SHALL MEET ALLOWABLE SPAN TABLES USING

'ASD' PRESSURES NOTED IN 'COMPONENT AND CLADDING' PRESSURES (TRIB AREA = 10

sf). NOTE THAT ALL PANELS THAT ARE CUT PARALLEL TO THEIR LENGTH SHALL BE

DESIGNED USING TABLE FOR PANELS WITH A MINIMUM OF TWICE THE WIDTH OF THE CUT

PANELS.

ANY PRODUCT SUBSTITUTIONS TO THE ABOVE WALL PANEL SYSTEM AS SHOWN SHALL

BE ACCOMPANIED BY SIGNED AND SEALED DRAWINGS AND CALCULATIONS BY A

REGISTERED PROFESSIONBAL ENGINEER AND SUBMITTED FOR REVIEW AND APPROVAL

PRIOR TO ORDERING ANY MATERIALS, OR FABRICATION OF ANY PANEL SUPPORT

FRAMING.

SUPPORTS FOR PANELS SHALL BE PROVIDED AS REQUIRED AT ALL PANEL EDGES, END

AND INTERMEDIATE SUPPORTS AS REQUIRED. ALL SUPPORTS SHALL BE DESIGNED FOR

WIND PRESSURES NOTED BASED ON 10 sf TRIBUTARY AREA AND A MAXIMUM DEFLECTION

OF (SPAN/180). ALL SUPPORTS SHALL BE A MINIMUM OF 3/16" THICK. PROVIDE

ADDITIONAL SUPPORTS IF/AS REQUIRED BEYOND THOSE SHOWN ON THE DRAWINGS

IF/AS REQUIRED, ACCOUNT FOR FIELD CONDITIONS ETC.

PROVIDE SHIMS OR SIMILAR MEASURES AS REQUIRED FOR FIELD ADJUSTABILITY AT

PANEL SUPPORT LOCATIONS.

ANY ADDITIONAL PANELS SUPPORTS AND FASTENERS THAT ARE REQUIRED ABOVE

WHAT ARE SHOWN ON THE DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO OWNER.

ALL PANEL CLIP FASTENERS SHALL BE A MINIMUM OF ¼" DIAMETER 304 STAINLESS STEEL

AND A MIN PULLOUT CAPACITY OF 2660#. PROVIDE FACTORS OF SAFETY OF 1.875 FOR

CLIPS AND 2.5 FOR FASTENERS.

4.

3.

6.

5.

2.

QS002

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

1317 EXECUTIVE BLVD.

SUITE 300

S U

E D

F O

R

8/

JAS

SEAL

SAT-TO FORM SIGNED BY

K

K

K

6'-4"10'-2 7/8"

K

K

K

K

K

6'-4"

K

K

33'-1 3/4"

10'-2 7/8"

NOTE;

A) ALL DIMENSIONS SHOWN ARE TO

CENTERLINE / CENTERLINE 'WORK

POINT' (W.P.) OF HSS COLUMNS

TYPICAL.

B) 'HSS' BEAMS AND 'L' BRACES ABOVE

FRAME ARE OFFSET AND FRAME INTO

CENTER OF HSS COLUMN FACES TYP

U.O.N.

HSS 8x4x1/2 COLUMN TYP

W/ EMBEDED BASE PL TYP

LEVEL 11 =

TOP CONC SLAB =

TOP BASE PL =

EL. EL: 171'-6"

SYMM ABT CL

CAB TYP U.O.N.

SYMM ABT CL

CAB TYP

U.O.N.

HSS 8x4

COLUMN TYP

M3

M8

M2

M1

M4

M5

M6

M9 M7

M10

ACCESS HOLE

LOCATIONS

TYP

M2

M3

M4

M5

M6

M7

M8

M9

M10

M1

A

C

C

E

S

S

D

O

O

R

APPROX LINE OF TOWER

BELOW (REF)

B

SCALE: 3/8" = 1'-0"

A2

CAB COLUMN BASE PLATE PLAN

N

(PARAPET AND ABOVE FINISHED FLOOR LOCATIONS SEE

DETAILS ON QS-501)

N

SCALE: NONE

A4

CABLE ACCESS HOLE LOCATION PLAN

0 2' 4' 6'

LINE OF CONT

CONC CURB (REF)

VERT 'L' CHEVRON

BRACING TYP U.O.N.

A1

QS501

APPROX LINE OF

CATWALK SLAB

EDGE (REF)

8'6'4'2'2' 1' 0'

GRAPHIC SCALE 3/8" = 1'-0"

C.L.

COL

C.L.

COL

C.L.

COL

C.L.

COL

C.L.

COL

C L

C O

L

C L

C O

L

C L

C O

L

C L

C O

L

C L

C O

L

C L

C O

L

A1

QS503

A2

QS503

QS101

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

W x

W x

W x

W x

W x

W x

3'-7"

7'-1 1/2"

EDGE DECK;

0'-9" TYP

W x

NOTE;

A) ALL DIMENSIONS SHOWN ARE TO

CENTERLINE/CENTERLINE 'WORK POINT' (W.P.)

OF HSS COLUMNS TYPICAL U.O.N..

B) 'W' BEAMS FRAME INTO CENTER OF HSS

COLUMN FACES TYP U.O.N.

C) 'HSS' BEAMS AND 'L' BRACES FRAME INTO

CENTER OF HSS COLUMN FACES TYP U.O.N.

TOP STEEL BM =

BOTTOM DECK =

EL. 187'-1"

W12 TO HSS

MOM CONN

TYP

SYMM

ABT CL

CAB TYP

U.O.N.

SYMM ABT CL CAB

TYP U.O.N.

M3

M2 M4

M5

M6

M1

M10

M9

M8

M7

ROOF ACCESS

LADDER OPENING

UPLIFT BRIDGING

2x2x

TYP

CONT BENT PLATE

L4x4x1/4

HSS 8x4 COLUMN TYP

C8x11.5

MONITOR

SUPPORT

SYSTEM;

SEE 'A5/QS501'

T

Y

P

L

D

E

S

37'-5 3/4"

C8x11.5

0 2' 4' 6'

N

SCALE: 3/8" = 1'-0"

A2

CAB ROOF FRAMING PLAN

W x

W x

W x

W x

W x

W x

0'-0 5/8"

W x

W x

W x

C.L.COL

FACE COL

C.L.COL C.L.COL

C.L.COL

C.L.COL C.L.COL

C.L.COL

C.L.COL

C.L.COL

C.L.COL

C.L.COL

C.L.COL

0'-9" 2'-6"±

3'-4"

WEATHERHEAD TYP.

SEE SECTION 'B5/S501'

L3x3x

TOP &

BOT TYP

L3x3x

VERT

HANGER

L3x3x

HORIZ W/

L2x2x

VERT

BRACES TYP

HSS 7x3x

BELOW TYP

WEATHERHEAD

SUPPORT

SYSTEM;

SEE 'B5/QS501'

8'6'4'2'2' 1' 0'

GRAPHIC SCALE 3/8" = 1'-0"

W x

W x

W x

3'-10 3/8"3'-9 1/2" 3'-10 3/8" 3'-9 1/2"

3'-7"

7'-1 1/2"

Q

B1

QS503QS503QS503QS503

B2D1 D2

QS102

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

TYPICAL ELEVATED CONCRETE FLOOR;

1) COORDINATE ALL EDGE OF SLAB DIMENSIONS, LOCATIONS AND ALL RELATED

DETAILS WITH ARCH'L DRAWINGS AND DETAILS AS REQ'D.

2) COORDINATE STEM STUD WALL LOCATIONS WITH CONCRETE FLOOR MAIN

STRUCTURE PLAN BELOW AS REQ'D (REF).

3) TYP FLOOR CONSTRUCTION; 3

" CONC SLAB (TOTAL) R/W 6x6 W2.1x2.1 WWF (IN

'FLATS') ON 26 GAGE

" METAL DECK ON COLD FORMED METAL FRAMING.

4) TYPICAL LIGHT GAGE FLOOR FRAMING SYSTEM:

- FLOOR FRAMING STUDS; 600SJ200-58 (50) @ 16" O.C. MAX TYP

- PERIM STEM STUD; WALL; 400SJ163-43 (50) VERT STUDS @ 16" O.C. MAX & CONT

400CR125-43 (50) TRACK TOP & BOT. ALIGN VERT STUDS W/ JOISTS ABOVE TYP

U.O.N..

- PERIM RIM JOIST / HEADER; CONT 600SJ200-58 (50)

M3

M4

M5

M6

M7

M8

M9

M10

M1

M2

0'-4"

PERIM STEM

WALL TYP

ELEVATED CONC SLAB

STRUCTURE:

SEE NOTES FOR

CONSTRUCTION DETAILS

RAISED

FLOORING

SYSTEM TYP

SCALE: 3/8" = 1'-0"

A2

ELEVATED SLAB FLOOR FRAMING PLAN

N

0 2' 4' 6'

8'6'4'2'2' 1' 0'

GRAPHIC SCALE 3/8" = 1'-0"

A3

QS501

QS103

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

/1

8/

SAT-TO FORM SIGNED BY

SCALE: 3/8" = 1'

B4

TYP. COLUMN SECTION

2'-3 3/8"

ROOF BEAM

WEB SLOT

CABLE ACCESS

HOLE

HS8x4 COLUMN

CABLE ACCESS

HOLE

COLUMN BASE

PLATE

MX

17'-5

"; CL/CL

C.L.

COL

5'-0"

L3x3x

FS

TYP HSS7x3x

TYP

0 2' 4' 6'

LEVEL 12

EL: 171'-6"

M3M4 M9M2 M1 M10

L x

W12 W12 W12W12W12

HSS 7x3x1/4 TYP

L x

L x x

L x x

L x x

L x x

CATWALK

T/S TUBE

EL: 192'-4"

T/S PARAPET

EL: 187'-3"

BOTTOM DECK

LVL 13 ROOF

T/ SLAB LVL 11

HSS 7x3

HSS 7x3

HSS 7x3

HSS 7x3

HSS 7x3

HSS 7x3

HSS7x3

HSS 7x3x3/8

HSS 7x3x1/4 TYP

HSS 7x3x3/8 TYP

HSS 7x3

HSS 7x3

H

S

S x

HSS 7x3

H

S

S x

HSS 7x3

H

S

S x

HSS 7x3

HSS 7x3

H

S

S x

HSS 7x3

H S

S x

H S

S x

HSS 7x3x3/8 TYP

RAF FLOOR

SCALE: 3/8" = 1'

B2

CAB STRUCTURAL FRAME ELEVATION

C L C

O L

S Y

M

C

C A

B

T

U

O

N

C L C

O L

C L C

O L

C L C

O L

C L C

O L

C L C

O L

L x

L

RAF FLOOR

C U

R B

L x x

L x x

HSS 7x3

C x

C x

L x x

L x x

SCALE: 3/8" = 1'

A2

FRAME ELEVATION AT ACCESS DOOR

0 2' 4' 6'

(REF)

C U

R B

R

E F

T/ SLAB LVL 11

EL: 171'-6"

L4x4 BRACE

HSS 8x4

INSULATED METAL

WALL PANELS OMITTED

FOR CLARITY TYP

L x x

INSULTED METAL

PANEL SIDING

(IMP) TYP

I.M.P.

TYP

IMP CLIP 'L' CONN

TO CURB TYP

IMP CLIP 'L' CONN

SUPPORT TO STEEL

FRAMING TYP

IMP CLIP 'L'

SUPPORT TYP

TYP CIP BASE CLIP

CONNECTOR SUPPORT;

L4x3x x 0'-8" W/ 2-

"Ø EXP

BOLTS W/ 4" MIN EMBED @ 5"

O.C. TYP

TYP CIP CLIP

CONNECTOR SUPPORT;

L3x3x x 0'-6" TYP

HSS 7x3

IMP JOINT TYP

PROVIDE CONT VERT L2x2x

EA SIDE HSS 8x4 COLS FOR

SUPPORTING IMP AT CUT /

MITERED JOINTS TYP

8'6'4'2'2' 1' 0'

GRAPHIC SCALE 3/8" = 1'-0"

T

Y

P

OPEN

B1

QS502

A1

QS502

B1

QS501

C3

QS501

C4

QS501

A1

QS501

A4

QS502

QS201

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

/1

8/

SAT-TO FORM SIGNED BY

SCALE: 1" = 1'

A1

CAB STRUCTURAL SECTION

EMBED PLATE (REF)

HSS 7x3

L4x4 VERT

BRACE

HSS 8x4 COL

BEYOND

CONT WINDOW

SUPPORT BENT

PLATE

L

C

SCALE: 1" = 1'

B1

CAB STRUCTURAL SECTION

HSS 7x3

HSS 8x4 COL BEYOND

8 " CONT WINDOW

SUPPORT BENT PL TYP

2" CAP PL

3-12

3-123/16

TYP

3/16

2" METAL DECK

HSS 7x3

L2x2 STRUTS BEYOND

AT CORNERS

HSS 8x4 COL BEYOND

HSS 7x3

TYP

3/16

3-123/16

3-12

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

I S

S U

D

D

1/4

TYP

4x9x

" PL

TYP

3/16

3-12

3-12

IMP SUPPORT;

CONT

" x3" PL

FOR WIDTH IMP

W12

2" W12

3/4"Ø A325 BOLTS

IN HORIZ SSH TYP

W12 BM TYP

TOP STEEL =

BOT DECK TYP

SEE PLAN

3" INSULATED METAL

WALL PANEL (IMP) TYP

HSS COL BEYOND

HSS 7x3

CONT

BENT PL;

(4

"+4

4"

HSS 7x3

'W' BEAM TYP (REF)

HSS STUB TUBE

COL (REF)

METAL FLOOR

DECK (REF)

CONC SLAB

(REF)

ELEVATED

FLOORING TYP

SCALE: 1 1/2" = 1'

C4

WINDOW HEAD SECTION

SCALE: 1 1/2" = 1'

C3

WINDOW SILL SECTION

SCALE: 1" = 1'

C5

BEAM CONN SECTION

SCALE: 1" = 1'

A3

ELEVATED SLAB SECTION

2'1'0'1' 6" 3'

GRAPHIC SCALE 1" = 1'-0"

2" CONC SLAB ON 0.6C

METAL DECK TYP WWF TYP

CONT 4" CR

TRACK T& B W/

FASTENERS TYP

CONT 8" HEADER TYP

4" STUDS @ 16" O.C.

TYP. ALIGN VERT

STUDS & JOISTS TYP

2-6" SJ JOISTS AT

MAX 30" OPN'G TYP

CONT 31

2 x 31

2"

POUR STOP L TYP

2" CONC SLAB ON M DECK

(REF). COORD W/ MAIN

STRUCTURAL DRAWINGS

FOR OPN'G LOCATIONS 'W' BEAM TYP (REF)

SLAB OPN'G (REF)

6" SJ JOISTS @ 16"

O.C. TYP

SCALE: 1" = 1'

B3

W12 / HSS 8x4 MOMENT CONN

W12

3/4" CAP PL

SEE TYP W12

SHEAR CONN

TOP & BOT

5/16

TYP

SYMM ABT

C.L.

HSS 8x4 COL

PROVIDE DBL STUDS

EA SIDE OPNG'S TO

32" MAX WIDTH TYP

2" IMP TYP

NOTE:

COORDINATE ALL FINISHES,

FLASHING, EQUIPMENT

ATTACHMENT AND OTHER

DETAILS ETC W/ ARCH'L TYP

3" IMP TYP

NOTE;

ALL BENT PLATE DIMENSIONS SHOWN FOR BOTH GLAZING

AND SIDING SUPPORTS ARE APPROXIMATE. COORDINATE

FINAL DIMENSIONS WITH ARCHITECTURAL DETAILS AND

FINAL APPROVED SHOP DRAWINGS AS REQUIRED.

COL BEYOND

HSS 8x4

W.P.

W.P.

9"

L4x3 LLH CONT

LOWER IMP

SUPPORT

CONT STUD

HEADER

GUSSET PL

SEE NOTE 2

NOTE 2:

TYP ACCESS HOLE: ONE SIDE OF HSS 8x4, 2" HORIZ & 61

2" VERT REINF WITH

8"x51

2"x9" PLATE, WELD TO HSS 8x4 W/ 14"

FILLET ALL AROUND. SEE CBS101 FOR

LOCN'S. NOTE: REINF PLATE REQD AT

ALL HSS 8x4 OPENINGS.

HSS 8x4 COL

BEYOND

C

L

NOTE 1;

TYPICAL 21

2" WIDE x 61

2" HIGH

ACCESS HOLE ONE SIDE OF HSS

8x4. SEE 'NOTE 2' FOR REINF.

SEE CBS 101 FOR LOC'NS

HSS 8x4 BEYOND

NOTE 1;

L4x4 VERT BRACE

TYP ALL MISC

ANGLES

1/8

TYP PLY SIDING &

SOFFIT SUPPORT;

L2x2x1/8 @ 24" O.C. TYP

1/8

1'-1"

CONT L2x2x1/8

9"

CONT VERT BENT PL

AT CORNERS TYP

CONT

BENT PL;

(4

+4

+ 2

W12 BEAM

3" IMP TYP

TYP

3-123/16

WEATHERHEAD

PIPE. SEE PLAN

W12 BM TYP

W12 BEAM

1/8

SCALE: 1" = 1'

B5

WEATHERHEAD SUPPORT SECTION

PARAPET OMITTED

FOR CLARITY

IMP SIDING

SEE SECTION

'B1/S501'

2" METAL DECK

L3x3x3/16 TOP & BOT.

SEE PLAN

SCALE: 1" = 1'

A5

MONITOR SUPPORT

PARAPET OMITTED

FOR CLARITY

1/8

3'-4" (N.T.S.)

SEE SECTION

'B1/S501'

W12 BM

L3x3x1

4. OMIT IF

HANGER UNDER

W12 BM

2" METAL DECK

L3x3x1

4 HANGER

W12 BEAM

IMP SIDING

TYP

L2x2x1

8 BRACES

TYP

CONT 3 8 x51

2" PL

CENTER ON HSS

HANGER TO HSS

3/16

HSS 8x4 BEYOND

HSS 8x4 BEYOND

PLY SHEATHING.

SEE ARCH'L FOR

ADD'L REQT'S TYP

CONT 3 8"

BENT PL: 9"+4"

2'-3"

1'

GRAPHIC SCALE 1 1/2" = 1'-0"

6" 0' 1' 2'

HSS 7x3

HSS 7x3

W12

HSS 7x3

HSS 7x3 1'-2".

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

QS501

/1

8/

SAT-TO FORM SIGNED BY

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

I S

S U

D

IMP TYP

L3x3 ANTENNA

SUPPT'S AT TOP AND

BOTTOM INSIDE

PARAPET TYP

IMP TYP

INSULATED METAL

PANELS (IMP) TYP

NOTE;

ALL 'L' CONN GUSSET

PLATES ARE

THICK TYP U.O.N.

SCALE: 1" = 1'

B1

TYP. CAB STRUCTURAL DETAIL

W12 TYP

TOP OF CURB

SCALE: 1" = 1'

A1

TYP CAB STRUCTURAL DETAIL

GUSSET TO

HSS TYP 5/16

WORK POINT

TOP OF SLAB

BEYOND

TOP OF

CONC CURB

SIDING EDGE

SUPPORT TYP

H S

S

P

L

A

C

I

N

G

23/16

RETURN

TYP

6"x1'-0"W

GUSSET PLATE

CONT BENT PL AT TOP OF

HORIZ HSS FOR WINDOW

SILL SUPPORT TYP

HSS 7x3 TYP

WORK POINT

3/8" BENT

THRU PL TYP

COL OPN'G

REINF PLATE

" CONT BENT

THRU PL

W12 BM

(BACKGROUND)

TYP

H S

S

P

END PL TYP

2x6x1/4 PL

NS & FS

3/16

1/4

4x6x1/4" PL TOP

WORK POINT

HSS 7x3 TYP

WORK POINT

GUSSETS

TYP

4"x8"W

GUSSET PL

1/4

CONT

" BENT PL

H S

S x

C

O L

T

Y P

TYP

1/4

L3x3 FS TYP

3/16

TYP

HSS7x3

3/16

TYP

HSS7x3

3/8" CAP PL TYP

3/16

TYP

HSS7x3

8"x4"W GUSSET

PLATE TYP

E.Q.

C U

R B

R

E F

CONT L4x3

LLH TYP

E.Q.

8"x6"W

GUSSET

PLATE TYP

3/16

NOTE; LOOKING INWARD

SCALE: 1" = 1'

A4

CAB STRUCTURAL DETAIL AT CATWALK DOOR

WORK POINT

TOP OF CURB

WORK POINT

COORD W/ ARCH'L

TOP OF SLAB

BEYOND

2'1'0'1' 6" 3'

GRAPHIC SCALE 1" = 1'-0"

TOP OF

CONC CURB

WORK POINT

HSS 7x3 TYP

L

A

C

I

N

G

NOTE: INSULATED METAL

PANEL (IMP) SUPPORT

STRUCTURE OMITTED

FOR CLARITY TYP

TYP

H S

S

P

L

A

C

I

N

G

COL OPN'G

REINF PLATE

'L' BRACE TO

GUSSET TYP1/4

1/4

CATWALK DOOR

OPENING

H S

S

P

C

C

M2

B

E Y

O N

D

L

P

4"x2'-0"W

GUSSET PL

4"x6"W

GUSSET PL

WORK POINT

SIDING EDGE

SUPPORT 3/16"

BENT PL NS TYP

L

A

C

I

N

G

H S

S

P

WORK POINT

M3

H S

S x

C

O L

T

Y P

L3x3x

FS TYP

SIDING EDGE

SUPPORT 3/16"

BENT PL NS TYP

CONT BENT PL AT BOT OF HORIZ

HSS FOR WINDOW HEAD

SUPPORT BEYOND TYP

IMP VERT

JOINT

L2x2 TYP

QS502

/1

8/

SAT-TO FORM SIGNED BY

SEE ARCH'L

HSS 8x4 COL

HSS 7x3

HSS 7x3

TYP

NOTE: C7 END CONNS SAME AS

HORIZ HSS TUBE TYP

SEE DETAIL

(A2/S503)

HSS 8x4 COL

W12

W12

9"H x3/8" x12"

BENT THRU PL

TYP

SCALE: 1" = 1'

D2

ROOF BEAM PLAN DETAIL

NOTE: CUT MAX

" OS VERT SLOT IN

HSS COL TO INSERT THRU PLATE TYP

LINE OF DECK SUPPORT

BENT PL ABOVE

CONT BENT PL.

SEE (A3/S503)

W1

HSS 8x4 COL

CONT WINDOW SILL SUPPORT

BENT PL TYP. COPE

" CLEAR

AT COL'S ETC TYP

TYP

1/4

HSS 8x4 COL

8"

5x3

8 PL NS & FS,

TOP & BOT, TYP

2x3

8 PL NS & FS

HSS 8x4 COL

TYP

1/4

CONT BENT PL AT

BOT OF HORIZ HSS

TUBE WINDOW HEAD

CONT 3 16" x (4+4) BENT PL TYP AT;

- 3" IMP SIDING BELOW WINDOW SILL

- 2" IMP SIDING AT PARAPET

RAISED CONC

CURB

EMBED PLATE

HSS 8x4 COL

4" SLAB STEP DOWN

TRANSITION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 31 JANUARY 2017

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

I S

S U

D

SCALE: 1" = 1'

D1

TYP. PARAPET PLAN DETAIL

H

HSS 7x3 HSS 7x3

5/16

TYP

3-12

TYP

5/16

1/4

3-

"Ø A325 BOLTS IN

HORIZ SSH TYP

INTERIOR

FACE IMP

SCALE: 1" = 1'

B1

HSS TUBE AT WINDOW SILL

SCALE: 1" = 1'

B2

HSS TUBE AT WINDOW HEAD

SCALE: 1" = 1'

A2

COLUMN CORNER PLATE DETAIL

SCALE: 1" = 1'

A1

COLUMN BASE PLATE DETAIL

INSULATED METAL

PANEL (IMP) TYP

PLY SHEATHING.

SEE ARCH'L FOR ADD'L

REQT'S TYP

1/8

TYP

PANEL JOINT

SUPP'T 'L'

HSS 8x4 COL

SCALE: 1" = 1'

A3

COLUMN CORNER PLATE DETAIL

CONT 3 16" x (4+4) BENT PL TYP

EXTERIOR COL'S AT 3" IMP

SIDING ABOVE WINDOW SILL.

L2x2x1

4 @ 24" O.C. MAX

SEE DETAIL

(A2 / S503)

SEE DETAIL

(A3 / S503)

BENT PL ABOVE.

SEE DETAIL (A2 / S503)

H

SEE DETAIL

(A3 / S503)

SCALE: 1" = 1'

B3

HSS TUBE AT WINDOW HEAD

HSS 7x3

H

CONT WINDOW HEADER

SUPPORT BENT PL TYP.

COPE

2" CLEAR AT COL'S,

CONN PL'S ETC TYP

2x3

8 PL NS & FS

HSS 8x4 COL

IMP CLIP

CONN TYP

2" SLAB STEP

DOWN TRANSITION

2'1'0'1' 6" 3'

GRAPHIC SCALE 1" = 1'-0" QS503

/1

8/

SAT-TO FORM SIGNED BY

DN

O

S

I

T

I

O

S

I

T

I

O

S I T

I O

N

P

O

S

I

T

I

O

S

I

T

I

O

S I T

I O

N

P O

S I T

I O

N

A

D

M

S

I

T

I

O

N

S U

P E

R V

I S

M

I N

D

N

10"

33'-1

4'-2"

M8

M7

M6

M5

M4

M3

M2

M9

M10

M1

SILL EL. 275'-10

CONSOLE EL. 275'-9"

R

E

F

F

I

L

E

FINISH FLOOR EL. 273'-3"

TOP COUNTER

EL. 276'-6"

FINISH FLOOR EL. 273'-10"

LANDING

EL. 271'-6"

CONSOLE EL. 276'-4"

S

I

N

K

POWER PANELS

TOP OF COUNTER

EL 276'-3"

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA100

A CB

11'-4"12'-8"

TOP GLASS

HR EL. 276'-9"

TOP WALL

EL. 275'-10

TOP GLASS

HR EL. 277'-4"

TOP COUNTER

EL. 274'-6"

STAIR

CAB

L E

V E

L

A

B O

V

U

N T

A

N

TOP OF

COUNTER

EL 276'-3"

TOP WALL

EL. 276'-6"

TOP WALL EL. 276'-6"

KEYED NOTES

CONSOLES FURNISHED AND INSTALLED BY

OTHERS

CHAIRS FURNISHED BY OTHERS

WINDOW SILL DIFFUSERS

FIRE ALARM ANNUNCIATOR NOTIFICATION PANEL

FIELD VERIFY WALL LOCATION WITH CONSOLE

MANUFACTURER

FIELD VERIFY LOCATION OF BASE CABINET AND

COUNTERTOP WITH CONSOLE MANUFACTURER

(TYP)

SCALE: 3/8" = 1'-0"

A2

LEVEL 13 ABOVE COUNTER

PLAN

N

0 2' 4' 6'

TOP

COUNTER

EL. 276'-6"

UTILITY MULLION SCHEDULE:

No. DESCRIPTION LOCATION

M1 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M1 POWER TO ROOF INSIDE OF MULLION

M2 SPRINKLER TO ABOVE CEILING INSIDE OF MULLION CAP

M3 LIGHTNING GROUNDING EXTERIOR OF MULLION

M3 COMMUNICATION TO ROOF INSIDE OF MULLION

M4 POWER TO ABOVE CEILING INSIDE OF MULLION

M4 LIGHTNING GROUNDING EXTERIOR OF MULLION

M4 COMMUNICATION TO ROOF INSIDE OF MULLION

M5 RADAR DISPLAY CONTROL WIRE INSIDE OF MULLION

M5 POWER TO ABOVE CEILING INSIDE OF MULLION

M6 COMMUNICATION TO ROOF INSIDE OF MULLION

M7 POWER TO ABOVE CEILING INSIDE OF MULLION

M7 LIGHTNING GROUNDING EXTERIOR OF MULLION

M8 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 POWER TO ABOVE CEILING INSIDE OF MULLION

M9 LIGHTNING GROUNDING EXTERIOR OF MULLION

M9 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 PLUMBING VENT INSIDE OF MULLION CAP

M10 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M10 FIRE ALARM TO ABOVE CEILING INSIDE MULLION

M10 LIGHTING GROUNDING EXTERIOR OF MULLION

FINISH LEGEND

RB-1 WALL BASE

CPT-3 ESD CARPET

RF-1 RUBBER TREADS/RISERS/LANDING

AP-2 ACOUSTICAL WALL COVERING

ACT-2 CEILING TILE

PNT-5 WALL PAINT

PNT-4 HANDRAIL PAINT

SEE DWG QG001 FOR ADDITIONAL REQUIREMENTS

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

DON ELLIOT 12/19/19

JAS

peted

Seal for all QA drawings

P

O

S

I

T

I

O

S

I

T

I

O

S I T

I O

N

P

O

S

I

T

I

O

S

I

T

I

O

S I T

I O

N

P O

S I T

I O

N

A

D

M

S

I

T

I

O

N

S U

P E

R V

I S

M

I N

DN

M8

M7

M6

M5

M4

M3

M2

M9

M10

M1

33'-1

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA101

A CB

11'-4"12'-8"

STAIR

CAB

L E

V E

L

B

E L O

W

C

O U

N T

A

N

KEY NOTES

CONSOLES FURNISHED AND INSTALLED BY OTHERS.

CHAIRS FURNISHED AND INSTALLED BY OTHERS

KNEE SPACE

FILE CABINET

COUNTER

UNDER COUNTER REF

HINGED ACCESS PANEL WITH PLASTIC LAMINATE FINISH 12"X12"

BASE CABINET

MILL-WORK ACCESS DOOR

FIRE EXTINGUISHER

R/A RETURN DUCT

RETURN AIR GRILL

SUPPLY AIR GRILL

BOOK SHELF CART

CUSTOM WEDGE MILLWORK PIECE - FIELD VERIFY LOCATION WITH

CONSOLE MANUFACTURER

(TYP)

SCALE: 3/8" = 1'-0"

A2

LEVEL 13 BELOW COUNTER

PLAN

N

0 2' 4' 6'

UTILITY MULLION SCHEDULE:

No. DESCRIPTION LOCATION

M1 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M1 POWER TO ROOF INSIDE OF MULLION

M2 SPRINKLER TO ABOVE CEILING INSIDE OF MULLION CAP

M3 LIGHTNING GROUNDING EXTERIOR OF MULLION

M3 COMMUNICATION TO ROOF INSIDE OF MULLION

M4 POWER TO ABOVE CEILING INSIDE OF MULLION

M4 LIGHTNING GROUNDING EXTERIOR OF MULLION

M4 COMMUNICATION TO ROOF INSIDE OF MULLION

M5 RADAR DISPLAY CONTROL WIRE INSIDE OF MULLION

M5 POWER TO ABOVE CEILING INSIDE OF MULLION

M6 COMMUNICATION TO ROOF INSIDE OF MULLION

M7 POWER TO ABOVE CEILING INSIDE OF MULLION

M7 LIGHTNING GROUNDING EXTERIOR OF MULLION

M8 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 POWER TO ABOVE CEILING INSIDE OF MULLION

M9 LIGHTNING GROUNDING EXTERIOR OF MULLION

M9 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 PLUMBING VENT INSIDE OF MULLION CAP

M10 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M10 FIRE ALARM TO ABOVE CEILING INSIDE MULLION

M10 LIGHTING GROUNDING EXTERIOR OF MULLION

9'-0" 8'-1" 16'-1"

SEE DWG QG001 FOR ADDITIONAL REQUIREMENTS

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

P

O

S

I

T

I

O

S

I

T

I

O

S I T

I O

N

P

O

S

I

T

I

O

S

I

T

I

O

S I T

I O

N

P O

S I T

I O

N

A

D

M

S

I

T

I

O

N

S U

P E

R V

I S

M

I N

DN

M8

M7

M6

M5

M4

M3

M2

M9

M10

M1

33'-1

LINE OF BASE CONSOLES

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA102

A CB

11'-4"12'-8"

R/A

R/A

S/A

R/A

STAIR

CAB

L E

V E

L

A

C C

E S

S

F

L O

A

N

SCALE: 3/8" = 1'-0"

A2

LEVEL 13 ACCESS FLOOR

PLAN

N

0 2' 4' 6'

UTILITY MULLION SCHEDULE:

No. DESCRIPTION LOCATION

M1 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M1 POWER TO ROOF INSIDE OF MULLION

M2 SPRINKLER TO ABOVE CEILING INSIDE OF MULLION CAP

M3 LIGHTNING GROUNDING EXTERIOR OF MULLION

M3 COMMUNICATION TO ROOF INSIDE OF MULLION

M4 POWER TO ABOVE CEILING INSIDE OF MULLION

M4 LIGHTNING GROUNDING EXTERIOR OF MULLION

M4 COMMUNICATION TO ROOF INSIDE OF MULLION

M5 RADAR DISPLAY CONTROL WIRE INSIDE OF MULLION

M5 POWER TO ABOVE CEILING INSIDE OF MULLION

M6 COMMUNICATION TO ROOF INSIDE OF MULLION

M7 POWER TO ABOVE CEILING INSIDE OF MULLION

M7 LIGHTNING GROUNDING EXTERIOR OF MULLION

M8 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 POWER TO ABOVE CEILING INSIDE OF MULLION

M9 LIGHTNING GROUNDING EXTERIOR OF MULLION

M9 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 PLUMBING VENT INSIDE OF MULLION CAP

M10 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M10 FIRE ALARM TO ABOVE CEILING INSIDE MULLION

M10 LIGHTING GROUNDING EXTERIOR OF MULLION

KEYED NOTES

RETURN AIR ACCESS FLOOR OPENING (NO RAF

PANEL REQUIRED)

SEE DWG QG001 FOR ADDITIONAL REQUIREMENTS

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

M8

M7

M6

M5

M4

M3

M2

M9

M10

M1

37'-8

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA103

A CB

11'-4"12'-8"

L E

V E

L

R

E F

L E

C T

I L I N

G

P

L A

N

KEY NOTES

SOFFIT PAINTED BLACK.

2'X2' SUSPENDED CEILING TILE AND GRID.

ROOF ACCESS LADDER AND HATCH.

HOUSE CLEANING LIGHT FIXTURES.

DIMABLE PENCIL DOWN LIGHT FIXTURES.

EXHAUST FAN GRILLE PAINTED BLACK.

OVERHEAD DISPLAY MOUNTING ABOVE CEILING.

(TYP)

(TYP)

CAB

SCALE: 3/8" = 1'-0"

A2

LEVEL 13 REFLECTED CEILING

PLAN

N

0 2' 4' 6'

UTILITY MULLION SCHEDULE:

No. DESCRIPTION LOCATION

M1 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M1 POWER TO ROOF INSIDE OF MULLION

M2 SPRINKLER TO ABOVE CEILING INSIDE OF MULLION CAP

M3 LIGHTNING GROUNDING EXTERIOR OF MULLION

M3 COMMUNICATION TO ROOF INSIDE OF MULLION

M4 POWER TO ABOVE CEILING INSIDE OF MULLION

M4 LIGHTNING GROUNDING EXTERIOR OF MULLION

M4 COMMUNICATION TO ROOF INSIDE OF MULLION

M5 RADAR DISPLAY CONTROL WIRE INSIDE OF MULLION

M5 POWER TO ABOVE CEILING INSIDE OF MULLION

M6 COMMUNICATION TO ROOF INSIDE OF MULLION

M7 POWER TO ABOVE CEILING INSIDE OF MULLION

M7 LIGHTNING GROUNDING EXTERIOR OF MULLION

M8 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 POWER TO ABOVE CEILING INSIDE OF MULLION

M9 LIGHTNING GROUNDING EXTERIOR OF MULLION

M9 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 PLUMBING VENT INSIDE OF MULLION CAP

M10 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M10 FIRE ALARM TO ABOVE CEILING INSIDE MULLION

M10 LIGHTING GROUNDING EXTERIOR OF MULLION

SEE DWG QG001 FOR ADDITIONAL REQUIREMENTS

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

M8

M7

M6

M5

M4

M3

M2

M9

M10

M1

37'-8

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA104

L E

V E

L

R

O O

F

P

L A

N

SLOPE TYP

KEYED NOTES

PARAPET

ROOF WALK PAD

ROOF HATCH

ROOF DRAIN (4 LOCATIONS)

ROOF EXHAUST FAN

PVC ROOF MEMBRANE

4" Ø GALV. PIPE ROOF PENETRATION (9

LOCATIONS)

TUBE STEEL ROOF PENETRATION AT EACH

PERIMETER MULLION

ANTENNA SUPPORT STRUCTURE

2" CONDUIT PENETRATIONS (2 LOCATIONS)

" PLUMBING VENT THROUGH ROOF

SCALE: 3/8" = 1'-0"

A2

LEVEL 14 ROOF PLAN

N

0 2' 4' 6'

UTILITY MULLION SCHEDULE:

No. DESCRIPTION LOCATION

M1 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M1 POWER TO ROOF INSIDE OF MULLION

M2 SPRINKLER TO ABOVE CEILING INSIDE OF MULLION CAP

M3 LIGHTNING GROUNDING EXTERIOR OF MULLION

M3 COMMUNICATION TO ROOF INSIDE OF MULLION

M4 POWER TO ABOVE CEILING INSIDE OF MULLION

M4 LIGHTNING GROUNDING EXTERIOR OF MULLION

M4 COMMUNICATION TO ROOF INSIDE OF MULLION

M5 RADAR DISPLAY CONTROL WIRE INSIDE OF MULLION

M5 POWER TO ABOVE CEILING INSIDE OF MULLION

M6 COMMUNICATION TO ROOF INSIDE OF MULLION

M7 POWER TO ABOVE CEILING INSIDE OF MULLION

M7 LIGHTNING GROUNDING EXTERIOR OF MULLION

M8 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 POWER TO ABOVE CEILING INSIDE OF MULLION

M9 LIGHTNING GROUNDING EXTERIOR OF MULLION

M9 COMMUNICATION TO ROOF INSIDE OF MULLION

M9 PLUMBING VENT INSIDE OF MULLION CAP

M10 ROOF DRAINS TO ABOVE CEILING INSIDE OF MULLION CAP

M10 FIRE ALARM TO ABOVE CEILING INSIDE MULLION

M10 LIGHTING GROUNDING EXTERIOR OF MULLION

SEE DWG QG001 FOR ADDITIONAL REQUIREMENTS

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA200

C A

B

E

X T

E R

I O

R

E

L E

V A

T I O

N

KEYED NOTES

PRE-MANUFACTURED COPING

2" INSULATED VERTICAL METAL SIDING PANEL

NOT USED

VERTICAL SIDING JOINT

3" INSULATED VERTICAL METAL SIDING PANEL

CLEAR CAB GLASS

(TYP)

M8

LVL 14 ROOF

T/S EL: 287'-3"

T/S PARAPET

EL: 292'-4"

LVL 13 CAB

EL: 273'-3"

LVL 13 CAB

EL: 271'-6"

SCALE: 3/8" = 1'-0"

A2

CAB EXTERIOR ELEVATION

0 2' 4' 6'

M7 M6 M5 M4 M3

GENERAL NOTES

SIDING INSTALLATION INSTRUCTIONS

1. STARTING POINT - CENTERED BETWEEN M5 AND M6 FOR PARAPET,

ABOVE AND BELOW WINDOWS.

BELOW WINDOWS - (4) 24" PANELS

- (1) 36" BENT PANEL EACH SIDE

PROVIDE EXPANSION JOINT BETWEEN M2 AND M3

ABOVE WINDOWS AND PARAPET - (5) 24" PANELS

- (1) 36" BENT PANEL EACH SIDE

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA300

C A

B

E

X T

E R

I O

R

E

L E

V A

T I O

N

KEYED NOTES

INSULATED METAL SIDING PANEL

CAB GLASS

WINDOW SILL DIFFUSERS

PVC PARAPET MEMBRANE

PVC ROOF MEMBRANE

ROOF DRAIN

SUSPENDED CEILING

GLASS HANDRAIL

6" SOUND INSULATION

RAISED ACCESS FLOOR

" Ø GALV. ANTENNA SUPPORT SYSTEM

HINGED ACCESS DOOR

CAB SHADES

4" Ø GALV. PIPE PENETRATIONS

(10 LOCATIONS)

4" S.S. WEATHERHEAD (10 LOCATIONS)

OVERHEAD DISPLAY MOUNT

ESD CARPET TILES

4" RUBBER BASE

GENERAL NOTES:

SEE SHEET QG-002 FOR CAB STRUCTURE

FIRE PROOFING

1.

LVL 14 ROOF

T/S EL: 287'-3"

T/S PARAPET

EL: 292'-1"

LVL 13 CAB

EL: 273'-3"

LVL 13 CAB

EL: 271'-6"

FLUID APPLIED

TRAFFIC

COATING

CAB

37'-8

A B C

SCALE: 3/8" = 1'-0" (QA-100)

A2

CAB CROSS SECTION

N

0 2' 4' 6'

3'-4"

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA301

C R

O S

S

S

E C

T I O

N

B

KEYED NOTES

INSULATED METAL SIDING PANEL

CAB GLASS

WINDOW SILL DIFFUSERS

PVC PARAPET MEMBRANE

PVC ROOF MEMBRANE

HSS P2 A500 ANTENNA SUPPORT SYSTEM

SUSPENDED CEILING

ACOUSTICAL WALL COVERING

6" SOUND INSULATION

RAISED ACCESS FLOOR

CAB SHADES

SPRINKLER PIPING

4" Ø GALV. PIPE PENETRATION (10 LOCATIONS)

4" Ø GALV. S.S. WEATHERHEAD (10 LOCATIONS)

ESD CARPET TILES

4" RUBBER BASE

3 2 1

CAB

CAB

LVL 14 ROOF

T/S EL: 287'-3"

T/S PARAPET

EL: 292'-1"

LVL 13 CAB

EL: 273'-3"

LVL 13 CAB

EL: 271'-6"

GENERAL NOTES:

SEE SHEET QG-002 FOR CAB STRUCTURE

FIRE PROOFING

1.

SCALE: 3/8" = 1'-0"

A2

CAB CROSS SECTION

N

0 2' 4' 6'

1317 EXECUTIVE BLVD.

SUITE 300

S

U E

D F

O R

8/

JAS

DSN

SAT-TO FORM

SIGNED BY

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA400

C A

B

P

L A

N

D

E T

A I L S

INSIDE

OUTSIDE

INSIDE OF

MULLION

CAP AT

M1, M2 & M10

INSIDE OF MULLION

EXTERIOR

OF MULLION

C JOINT

L

T/S

EL: 275'-9"

TOP SLAB

EL: 271'-6"

E

D

L

L

"11

KEYED NOTES

3" INSULATED VERTICAL METAL SIDING PANEL

" PRESSURE AND FIRE TREATED PLYWOOD

SHEATHING

2" INSULATED VERTICAL METAL SIDING PANEL

(PARAPET ONLY)

BASE EXTRUSION

" GYP BOARD EACH SIDE ON 3

" METAL STUDS

AT 24" ON CENTER

.050 DARK BRONZE SILL FLASHING OVER 1

PRESSURE AND FIRE TREATED PLYWOOD

SHEATHING

PLASTIC LAMINATE ON

" FIRE TREATED

PLYWOOD

NOTCH AND BEND INSULATED SIDING PANELS AT

ALL CORNERS

20 GAUGE METAL BACKING BENT PLATE

STEEL TUBE COLUMN

" GYP BD ON 1 5/8" 20 GAUGE STUDS @24" O.C.

6" SOUND BATT INSULATION

" GYP BD ON 2

" METAL STUDS @ 24" O.C.

DARK BRONZE ALUMINUM CURTAIN WALL

CLEAR CAB GLASS

.050 DARK BRONZE ALUMINUM COLUMN RAP (ALL

COLUMNS)

" HORIZONTAL UNISTRUT AT EACH COLUMN

BEND (MAX 5' 0" VERTICAL SPACING) AT MULLION

M1,M2,M10

PLASTIC LAMINATE OVER

" FIRE TREATED

PLYWOOD SILL

2 LAYERS

" FIRE TREATED PLYWOOD SOFFIT

PAINTED BLACK

" FIRE TREATED PLYWOOD PAINTED BLACK

SUSPENDED BLACK ACOUSTICAL CEILING TILE

STEEL CHANNEL EACH SIDE OF FRAME OPENING

FIRE EXTERIOR SEMI RECESSED CABINET

DARK BRONZE ALUMINUM DOOR AND FRAME

PREMANUFACTURED ALUMINUM COPING WITH

CLEAT EACH SIDE

CUSTOM CORNER PREMANUFACTURED ALUMINUM

COPING WITH CLEAT EACH SIDE

HSS P2 A500 ANTENNA SUPPORT STRUCTURE

4" SS WEATHER HEAD

STEEL TUBE STRUCTURE

40 MILL PVC PARAPET MEMBRANE OVER

PRESSURE AND FIRE TREATED PLYWOOD

SHEATHING

RAISED CONCRETE CURB

RUBBER TILE

.050 SILL FLASHING

GENERAL NOTE

SEE MILL WORK DRAWINGS FOR INTERIOR

WINDOW SILLS AND COUNTERS

SEE SHEET QG-002 FOR CAB STRUCTURE FIRE

PROOFING

1.

2.

SCALE: 3" = 1'-0" (QA-103)

C1

TYP CAB CORNER DETAIL

SCALE: 3" = 1'-0"

B1

TYP SIDING VERTICAL JOINT

DETAIL

SCALE: 3" = 1'-0"

A1

TYP SIDING CORNER DETAIL

SCALE: 3/4" = 1'-0" (QA-101)

D2

PLAN DETAIL

SCALE: 3/4" = 1'-0" (QA-101)

A2

CATWALK DOOR DETAIL

SCALE: 3/4" = 1'-0" (QA-100)

C2

PLAN DETAIL

SCALE: 3/4" = 1'-0" (QA-103)

B2

PLAN DETAIL

SCALE: 3/4" = 1'-0" (QA-104)

C3

PARAPET PLAN DETAIL

SCALE: 3/4" = 1'-0" (QA-104)

D3

PARAPET PLAN DETAIL

SCALE: 3" = 1'-0"

A3

CATWALK DOOR DETAIL

6 1

0 4" 8"0 4" 8"

0 4" 8"

0 4" 8"

0 1' 2' 3'

0 1' 2' 3'

0 1' 2' 3'

0 1' 2' 3'

0 1' 2' 3'

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

P O

S I T

I O

N

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA401

C A

B

P

L A

N

D

E T

A I L S

KEYED NOTES

1.

2.

SCALE: 3/4" = 1'-0" (QA-101)

C2

PLAN DETAIL

SCALE: 3/4" = 1'-0" (QA-101)

B1

PLAN DETAIL

SCALE: 3/4" = 1'-0" (QA-101)

B2

PLAN DETAIL

M1

6"

3 4

17217

16 19

1'-11" ROUGH OPENING

0 1' 2' 3'0 1' 2' 3'

0 1' 2' 3'

3'-10

" 10

" 3'-1

" 1'-5

6"

1317 EXECUTIVE BLVD.

SUITE 300

CHESAPEAKE, VA 23320

/1

8/

SAT-TO FORM SIGNED BY

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

FY

P -2

A

TC

T

O W

E R

A N

D A

IR

O

P E

R A

TI

O

N S

QA500

C A

B

P

L A

N

D

E T

A I L S

WINDOW SILL

CAB/CURB SIDING

T/S

EL. 275'-9"

TOP WINDOW SILL

EL. 275'-10 1/2"

TOP COUNTER

EL. 276'-3"

TOP SLAB

EL. 275'-7"

TOP WINDOW SILL

EL. 275'-10 1/2"

TOP FINISHED FLOOR

EL. 273'-3"

TOP SLAB

EL. 271'-6"

TOP FINISHED FLOOR

EL. 273'-10"

TOP SLAB

EL. 271'-6"

TOP FINISHED FLOOR

EL. 273'-10"

TOP SLAB

EL. 271'-6"

TOP FINISHED FLOOR

EL. 273'-3"

TOP FINISHED FLOOR

EL. 273'-3"

TOP SLAB

EL. 271'-6"

1'-0"

1'-0"

COL

TOP SLAB

EL. 273'-10"

TOP SLAB

EL. 271'-6"

HORIZONTAL JOINT

KEYED NOTES

" GYPSUM BOARD EACH SIDE ON 3

"METAL

STUDS AT 24" O.C.

3" LIGHTWEIGHT CONCRETE SLAB OVER METAL

DECK

6" METAL JOIST AT 16" O.C.

RAISED ACCESS FLOOR

2 1/2" METAL STUD 20 GA.PERIMETER ACCESS

FLOOR SUPPORT

DARK BRONZE ALUMINUM CURTAINWALL

CLEAR CAB GLASS

.050 DARK BRONZE SILL FLASHING OVER

BENT PLATE CURTAIN WALL SUPPORT

STRUCTURE

3" INSULATED METAL SIDING PANEL

" FIRE AND PRESSURE TREATED WOOD

NAILERS

SIDING SUPPORT ANGLE

BASE EXTRUSION WITH WEEP HOLES

CABLE ACCESS HOLE

INSULATED ROOF DRAIN PIPING

DARK BRONZE ALUMINUM HANDRAIL WITH

LAMINATED GLASS INSERT

PLASTIC LAMINATE ON FIRE RETARDANT

" WALL

CAP

6" SOUND BATT INSULATION

" GYPSUM BOARD ON 2 1/2" 20GA. METAL STUDS

AT 24"O.C.

" 20 GAUGE METAL STUDS AT 24" O.C.

WINDOW SILL DIFFUSERS WITH SUPPLY DUCT

BELOW

PLASTIC LAMINATE ON 2 LAYERS OF

" FIRE

TREATED PLYWOOD

RAISED CONCRETE CURB

PRE-FINISHED METAL CLOSURE BY ACCESS

FLOOR MANUFACTURE

2 LAYERS

" TYPE X GYPSUM BOARD (2HR RATED

FLOOR/CEILING ASSEMBLY)

2 HOUR LOAD BEARING WALL WITH 2 LAYERS

GYPSUM BOARD EACH SIDE ON 3

" 20GA. METAL

STUDS AT 24" O.C.

CONCRETE FILLED STEEL PAN STAIR

2"X2"X

" STAIR SUPPORT LEG(2 REQUIRED) WITH

BASE PLATE

RUBBER TREADS, RISERS, AND LANDINGS

STAIR STRINGER PAINTED

" 20 GAUGE METAL STUD

" GYP BOARD EACH SIDE ON 3

" 20GA. METAL

STUDS AT 24" O.C.

4" RUBBER BASE

RUBBER TILE

ACOUSTICAL WALL COVERING

GYP BOARD NOT REQUIRED BELOW ACCESS

FLOOR

GENERAL NOTE

SEE MILL WORK DRAWINGS FOR INTERIOR

WINDOW SILLS AND COUNTERS

SEE SHEET QG-002 FOR CAB STRUCTURE FIRE

PROOFING

1.

2.

4 4

"1

1 2

SE…