This document outlines room requirements for a five-story parking structure to be constructed at Marine Corps Air Station Cherry Point in North Carolina. Key details include specifications for parking spaces on each level, an elevator and elevator lobby, vestibule, mechanical and electrical rooms, and access stairs. Requirements cover dimensions, finishes, signage, doors and hardware, fire suppression, plumbing and electrical systems. The related federal contract opportunity is solicitation number N4008521R2516 for design and construction of a new aircraft maintenance hangar at MCAS Cherry Point, of which the parking structure would be a component. The response due date is not provided.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 1
5.5 PARKING STRUCTURE (PS)
PARKING STRUCTURE POV PARKING
Space Characteristics
Function/adjacencies: Locate each floor of a five-story ramped facility. For the purpose of ROOM REQUIREMENTS, this description applies to POV PARKING on all five levels, MOTORCYLE PARKING and ACCESSIBLE PARKING.
Special Dimensions:
Ideal Plan Dimensions:
Minimum Ceiling Height:
Acoustics: No acoustic requirements Access: From exterior Number of Occupants: None
Other/special requirements: Contractor’s Interior Designer to determine FF&E requirements based on in-depth interviews with the Activity at the Concept Design Workshop. Space must accommodate at a minimum: Fire Extinguishers (in cabinet). Design PS POV PARKING to allow no ponding of water anywhere on the structure.
Uniformat
Section Description Qty Size Specific Requirements
B2030 Exterior Doors AR 2 -3’ x 8-0” min.
Maximum-duty steel double door and frame, insulated.
Paint. Coordinate door sizes with equipment sizes.
B2030 Door Hardware AR AR Provide continuous hinge, full weather stripping, overhead holders, rain deflector, etc.
C103090 Other Specialties AR AR Provide an Avian Intrusion Prevention System
C3010 Wall Finish AR AR Exposed. Unpainted.
C3020 Floor Finish AR AR Sealed concrete.
C3030 Ceiling Finish AR AR Provide unpainted exposed prefab concrete panels.
D202002 Valves & Hydrants AR AR Hose bib
D4020 Fire Suppression Water Supply and Equipment
AR AR Fire Suppression Sprinkler Riser
D50 Electrical AR AR Per Part 3, Chapter 6, D50
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 2
PARKING STRUCTURE ELEVATOR
Function/adjacencies: Provide space for vertical circulation equipment. Locate adjacent to HANGAR structure and INTERNAL STAIR.
Special Dimensions: Ceiling Height: 8’-0” min. clear interior car height Acoustics:
Access: Provide direct access to all parking structure levels and elevator lobby Number of Occupants:
Other/special requirements: Provide passenger elevator designed to accommodate handicapped accessibility and emergency medical services including a 24” x 84” ambulance stretcher. See UFC 3-490-06 for Elevator Design. Provide connection to emergency generator. Provide protection from moisture, dust and corrosion.
Description Qty Size Specific Requirements
C1010 Interior Partitions AR AR Cast-in-place concrete elevator hoist way. Extend to underside of roof structure above or cap as required. Fire- Rated as required.
C102091 Interior Door AR 4’-0” x 7’-0” min.
Two-speed side sliding horizontal. Stainless steel doors and frames.
C103004 Identifying Devices AR AR Level identification at each stop.
Additional signage per code requirements.
C3010 Wall Finish AR AR Stainless steel panels with concealed fasteners and stainless steel handrails.
C3020 Floor Finish AR AR Rubber tile.
C3020 Wall Base AR AR Stainless steel.
C3030 Ceiling Finish AR AR Modular metal ceiling panels with integrated lighting.
D101002 Passenger Elevators AR AR
Electric Traction Four-stop (approx. 18’-0” floor to floor travel length) Rated Load: 4,500 lbs. minimum Rated Speed: 150 fpm minimum
D20 Elevator Sump Pump AR AR Sump Pump required. One per Elevator.
D50 Electrical AR AR In accordance UFC.
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 3
PARKING STRUCTURE ELEVATOR ENTRY VESTIBULE
Function/adjacencies: Locate on the top level. Provide an ELEVATOR ENTRY VESTIBULE as the main point of entry to the elevator from the top level of the parking structure.
Special Dimensions:
Acoustics: No special acoustic requirements.
Access: Provide access from the top level of the parking structure.
Number of Occupants:
Other/special requirements: Provide protection from moisture, dust and corrosion.
Description Qty Size Specific Requirements
B202003 Curtain Wall AR AR Prefinished aluminum-framed curtain wall system with laminated glass. Assembly to include integral aluminum-framed curtain wall entry double-door. (PR 3-0” x 8’0” min.)
C1010 Interior Partitions AR AR CMU. Extend to underside of floor/roof structure above.
C1020 Interior Doors AR 6’-0” x 7’-0” min.
Provide maximum-duty, Coordinate with curtain wall system– fire rated as required -- Coordinate door sizes with occupant load and associated equipment sizes.
C103014 Entrance Floor Grilles and
Mats
AR AR
Recessed walk-off floor grille/mat. System must be removable for servicing and cleaning.
C3010 Wall Finish AR AR CMU/concrete. Painted.
C3020 Floor Finish AR AR Rubber tile beyond entrance mat.
C3030 Ceiling Finish AR AR Provide painted exposed structure.
C3040 Interior Coatings AR AR Paint CMU/concrete walls and ceiling, including ductwork, conduit, piping, devices, etc.
D30 HVAC AR AR Heating, ventilation and air conditioning systems.
D30 HVAC AR AR Condition fire alarm panel ambient to NFPA 72 conditions.
D4010 Fire Alarm and Detection
Systems AR AR Fire Alarm System Components Fire Alarm Annunciator
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 4
PARKING STRUCTURE ELEVATOR EQUIPMENT ROOM
Function/adjacencies: Provide space for Elevator mechanical and electrical equipment. Locate on ground floor adjacent to ELEVATOR.
Special Dimensions:
Acoustics:
Access: Provide direct access from ground floor of parking structure.
Number of Occupants:0
Other/special requirements: See UFC 3-490-06 for Elevator Design and equipment. Provide connection to emergency generator. Provide protection from moisture, dust and corrosion.
Description Qty Size Specific Requirements
C1010 Interior Partitions AR AR Cast-in-place concrete. Extend to underside of roof structure above or cap as required. Fire-Rated as required.
C102091 Interior Door AR 4’-0” x 7’-0” min.
Provide maximum-duty, painted steel door, fire rated as required, with painted steel frame.
C3010 Wall Finish AR AR Concrete. Unpainted.
C103004 Interior/Exterior Signage AR AR Room number identification at each room entry.
C3020 Floor Finish AR AR Sealed concrete
C3020 Wall Base AR AR Utilize an epoxy based sealant caulking bead where concrete floor meets CMU wall.
C3030 Ceiling Finish AR AR Provide unpainted exposed structure.
D101002 Passenger Elevators AR AR
Electric Traction Four-stop (approx. 18’-0” floor to floor travel length) Rated Load: 4,500 lbs. minimum Rated Speed: 150 fpm minimum
D503001 Telecommunication
Systems 1 AR Wall phone outlet: (W).
D50 Electrical AR AR Per Part 3, Chapter 6, D50 for machine room.
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 5
PARKING STRUCTURE ACCESS/EXIT STAIR
Function/adjacencies: Locate each floor of five-story ramped facility.
Acoustics: No special requirements.
Access: From each POV PARKING area Number of Occupants: None
Other/special requirements: Provide skid, slip and stain resistant concrete floor finish. Provide feature element of Aluminum Storefront.
Provide exterior signage
Uniformat Section
Description Qty Size Specific Requirements
B202002 Aluminum-framed Exterior-grade Storefront Systems
AR AR
Provide full-width prefinished aluminum-framed storefront with tempered clear glass and transom.
B2030 Exterior Doors AR 3’ x 8-0” min.
Maximum-duty steel door and frame, insulated. Paint.
Coordinate door sizes with equipment sizes.
B2030 Door Hardware AR AR Provide continuous hinge, full weather stripping, overhead holders, rain deflector, etc.
C103004 Exterior Signage AR AR Room name, number, and level identification at each stair entry. Include graphic signage at each stair entrance.
C2010 Stair Construction AR AR Provide primed and painted steel with concrete filled pans or cast-in-place concrete
C201090 Stair Handrails Guardrails and Accessories AR AR Provide aluminum handrails.
C2020 Stair Finish AR AR Provide sealed concrete stairs with cast aluminum stair nosing at cast in place concrete. Paint all exposed steel components including stringers where applicable.
C3010 Wall Finish AR AR Exposed. Unpainted.
C3020 Floor Finish AR AR Sealed concrete
C3020 Wall Base AR AR Utilize an epoxy based sealant caulking bead where concrete floor meets CMU wall.
C3030 Ceiling Finish AR AR Provide exposed unpainted structure
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 6
PARKING STRUCTURE ELECTRICAL ROOM
Function/adjacencies: Locate first level of five-story ramped facility.
Acoustics: No acoustic requirements Access: From first level POV Parking Number of Occupants: None
Other/special requirements: Provide protection from moisture, dust and corrosion.
Description Qty Size Specific Requirements
B2030 Exterior Door AR 3’ x 8-0” min.
Maximum-duty steel door and frame, insulated. Paint.
Coordinate door sizes with equipment sizes.
B2030 Door Hardware AR AR Provide continuous hinge, full weatherstripping, overhead holders, rain deflector, etc.
C3010 Wall Finish AR AR Exposed. Unpainted.
C3020 Floor Finish AR AR Sealed concrete.
C3020 Wall Base AR AR Utilize an epoxy based sealant caulking bead where concrete floor meets CMU wall.
C3030 Ceiling Finish AR AR Provide unpainted exposed structure.
D305002 HVAC AR AR Unit Heater (Electric)
D4020 Fire Suppression Water Supply and Equipment
AR AR Fire Suppression Sprinkler Riser
D50 Electrical AR AR Per Part 3, Chapter 6, D50
D5010 Electrical Service and
Distribution
AR AR
Provide necessary equipment for Electrical Service and Distribution, including service entrance.
P197 - PART 3 - CHAPTER 5.5 – PARKING STRUCTURE REQUIREMENTS - Page 7
PARKING STRUCTURE MECHANICAL ROOM
Function/adjacencies: Locate on the top level. Provide non-secured support space for mechanical building systems. Consider equipment replacement and crane locations.
Special Dimensions: Ceiling Height: Exposed Acoustics: Provide partition and door construction with a minimum STC rating of 50.
Access: From top level of parking area via double doors.
Provide exterior access with through-the-wall access doors on building exterior for crane access - with removable hand and safety rails. In accordance with UFC 3-410-01 HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS, section 4‐2.4.5.
Number of Occupants:
Other/special requirements: Design the Mechanical space and the building to readily enable service or replacement of the largest piece of mechanical equipment. Provide protection from moisture, dust and corrosion.
Description Qty Size Specific Requirements
C1010 Interior Partitions AR AR CMU. Extend to underside of floor/roof structure above.
C1020 Interior Doors AR 6’-0” x 7’-0” min.
Provide maximum-duty, painted steel double door – fire rated as required -- with vision panel and painted steel frame. Coordinate door sizes with occupant load and associated equipment sizes.
B2030 Exterior Doors AR
6’-0” x 7’-0” min.
Provide maximum-duty, painted steel double doors – fire rated as required -- with painted steel frame. Coordinate door sizes with occupant load and associated equipment sizes.
C103004 Interior/Exterior Signage AR AR Room number identification at each room entry.
C3010 Wall Finish AR AR Exposed. Unpainted.
C3020 Floor Finish AR AR Sealed concrete.
C3020 Wall Base AR AR Utilize an epoxy based sealant caulking bead where concrete floor meets CMU wall.
C3030 Ceiling Finish AR AR Provide unpainted exposed structure.
D202002 Valves & Hydrants AR AR Hose bib Floor mounted drain
D203090 Other Sanitary Waste AR AR Hub drains for condensate.
D305002 HVAC AR AR Unit Heater
D50 Electrical AR AR Per Part 3, Chapter 6, D50
D503001 Telecommunication
Systems 1 AR Wall phone outlet: (W).
D503001 Telecommunication
Systems
1 AR
Dedicated Fiber Outlet for DDC Panel. Coordinate requirements with DDC Installer.