Attachment U - DOR Basis of Design.pdf

PDF 754 KB Posted

Attached to
Design-Bid-Build, Repair B3 Mahan Hall, Naval War College, Naval Station Newport, Newport, RI
Solicitation number
N4008521R0164
Issued by

View the file

Other files

File Type Posted
N4008521R0164Rev5.pdf PDF
N4008521R0164 Amendment 0008.pdf PDF
Attachment R - MEI 2016-2018 Package and Parts Catalog.pdf PDF
Attachment P - 074213 METAL WALL PANELS.pdf PDF
Attachment S - United Drilling Review_Mahan Hall.pdf PDF
Attachment T - Inside Air Drilling Double Sided Info Sheet.pdf PDF
N4008521R0164 Amendment 0007.pdf PDF
Attachment Q - Elevator Disconnect.pdf PDF
N4008521R0164Rev4.pdf PDF
N4008521R0164 Amendment 0006.pdf PDF
Attachment M - Door Hardware Revisions.pdf PDF
Attachment L - 01 32 17.00 20 NAS rev 3_30_2021Mahan.pdf PDF
Attachment O - Second Site Visit Log.pdf PDF
Attachment N - Amendments Acknowledged.pdf PDF
N4008521R0164Rev3.pdf PDF
Attachment A_Revised - CIVIL COMBINED.pdf PDF
Attachment A_Revised - FIRE PROTECTION COMBINED.pdf PDF
Attachment A_Revised - MECHANICAL COMBINED.pdf PDF
Attachment A_Revised - STRUCTURE COMBINED.pdf PDF
Attachment A_Revised - PLUMBING COMBINED.pdf PDF
N4008521R0164 Amendment 0005.pdf PDF
Attachment K - Updated Base Access Requirements.pdf PDF
Attachment A_Revised - HAZMAT COMBINED.pdf PDF
Attachment A_Revised - LIFE SAFETY COMBINED.pdf PDF
Attachment A_Revised - ELECTRICAL COMBINED.pdf PDF
Attachment A_Revised - 201130_Mahan_Specifications.pdf PDF
Attachment A_Revised - ARCHITECTURE COMBINED.pdf PDF
Attachment A_Revised - FIRE ALARM COMBINED.pdf PDF
Attachment J - Added SOW_Ridem Permit_Test Pit_ Retention.pdf PDF
N4008521R0164 Amendment 0004.pdf PDF
Attachment I-Site Visit Attendee Form.xlsx XLSX spreadsheet
N4008521R0164Rev2.pdf PDF
Attachment G-SOW Mahan Hall Archives.pdf PDF
N4008521R0164 Amendment 0003.pdf PDF
Attachment H - Contractor Laydown Area.pdf PDF
Attachment E - SECNAV FORM 5512 EXAMPLE.PDF PDF
Attachment F-Site Visit Log.pdf PDF
N4008521R0164 Amendment 0002.pdf PDF
Attachment E - Verification of Mode of Transportation Form.xlsx XLSX spreadsheet
N4008521R0164Rev1.pdf PDF
N4008521R0164 Amendment 0001.pdf PDF
Attachment C- Pre-Proposal Inquiry Form.xlsx XLSX spreadsheet
Attachment A- A-300s.pdf PDF
Attachment A- I-100s.pdf PDF
Attachment E- SECNAV Form 5512-NSNPT- Dec 2019.pdf PDF
Attachment A- A-400s.pdf PDF
Attachment A- AD-100s.pdf PDF
Attachment A- A-200s.pdf PDF
Attachment E- CO Vetting Memo.pdf PDF
Attachment A- FIRE PROTECTION COMBINED.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE NAVY

NAVAL FACILITIES ENGINEERING COMMAND, MID ATLANTIC

PUBLIC WORKS DEPARTMENT, NAVAL STATION NEWPORT

ONE SIMONPIETRI DRIVE

NEWPORT, RHODE ISLAND 02841-1711

AMENDMENT

DATE: April 02, 2021

PROPOSED TASK ORDER: N4008521R0164 Design-Bid-Build, Repair B3 Mahan Hall, Naval War College, Naval Station Newport, Newport, RI

DATE OF SOLICITATION: February 12, 2021 HUBZONE MACC CONTRACT

HOLDERS

THIS AMENDMENT INCLUDES:

-Basis of Design cut sheets from Elevator Manufacturer and Elevator Control Switch (as attached) -Basis of Design cut sheet/plan from United Drilling Company (as attached) -Revised Response to PPI #33 - Addition of Specification SECTION 07 42 13 METAL

WALL PANELS (as attached) -DOR Basis of Design (Provided below)

Below is the DOR Basis of Design-

“New Elevator and Accessible Ramp with Entrance The existing connection from the DeWeldon Walkway to the existing egress stair in the 1960’s addition to Naval War College Mahan Hall building will be reconfigured and enlarged to include a new accessible ramp and an elevator machine room and entrance to an elevator lobby for the new in-ground piston type hydraulic, stretcher compliant elevator with front access to provide access to all four levels of the building.

Proposed Elevator Equipment (BOD – 3500 lb. Inground Borehole Passenger Elevator by MEI Total Elevator Solutions): A new stretcher compliant hydraulic (single-stage in-ground jack) elevator. Design capacity of the new elevator will be rated for 3500 lb.

capacity with a travel speed of 150 feet per minute (fpm) and front openings to enable access to all levels. The elevator equipment will be customized to enable front access at all floor levels. The customization is required due to the shorter than standard travel distance available between the existing floor levels resulting in a custom elevator equipment design. The MEI elevator model is customizable to accommodate the existing limited floor to floor distances. Inside clear dimensions of the elevator Cab will be 6'-8" by 5'-5" with single speed type 3'-6" wide doors at each level. Proposed Elevator Cab finishes are comprised of wood core laminate wall panel design, stainless steel base and rails, suspended white translucent ceiling light diffuser, brushed stainless steel doors and frames at each level, and traditional car fixtures in brushed stainless-steel faceplates with LED-illuminated signals.”

File details come from the government source that posted it. Updated .