This notice solicits proposals for a design-build construction contract to complete two military construction projects at Marine Corps Base Camp Lejeune in North Carolina. The projects include replacing the Onslow Beach Bridge over the Intracoastal Waterway and replacing two railroad trestles over the White Oak River and Queens Creek. The contract will be a firm-fixed-price contract with an anticipated completion time of 1,826 calendar days from award. Proposals are due by 7 October 2019 and contract award will occur by 20 July 2020. The solicitation will use a two-phase evaluation including technical approach, past performance, safety, technical solution, project management, and price factors. The contract is valued between $100-250 million and is set aside for unrestricted full and open competition without a reasonable expectation for small business participation.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Prepared by:
3802 Cherry Ave.
Wilmington, NC 28403
Tel: (910) 763-3445
Fax: (910-763-3415
Pre Demolition Lead Paint/Creosote Survey
At: White Oak Bridge
White Oak, NC
Prepared for: Kimley-Horn
11818 Rock Landing Dr. Suite 100
Newport News, VA 23608
PEI Project No.: 5269-20-0001-2AL
Date:
Inspector:
March 23, 2020
Jonathan Guetta
NC Lead Inspector/Risk Assessor Certification # 120097
3802 Cherry Ave. Wilmington, NC 28403 Tel: 910-763-3445 Fax: 910-763-3415 www.precision-enviro.com
Kimley-Horn
Attn: Scott Borges, PE
Re: Lead Paint Bulk Sampling & Analysis at:
White Oak Bridge
White Oak Bridge, NC
PEI Project No.:5269-20-0001-2AL
Precision Environmental Inc. (Precision) was retained by Kimley-Horn to conduct a lead paint survey and analysis of coated surfaces associated with the above referenced structure. The inspection included all materials scheduled to be disturbed/removed during the upcoming demolition procedures.
The purpose of the survey was to determine if lead painted components exist on painted components prior to upcoming demolition procedures.
The bulk sampling was performed by Precision’s representative, Jonathan Guetta (NC Risk Assessor/ Lead Inspector
Certificate No. 120097) on February 28, 2020.
OSHA defines any detectable level of lead in paint a concern when renovations/demolition will impact lead coated surfaces.
As a result, a total of three (3) different suspect lead based paint (LBP) coatings were identified. A listing of the identified
LBP coatings and the number of bulk samples collected per suspect material is provided in Table 1 below:
Table 1: Identified suspect LBP coatings materials
Suspect Material Location No. of Samples
Collected
1. White painted metal vertical safety beam Bridge 2
2. Gray painted metal main bridge stringer Bridge 6
3. Black painted metal vertical sheet piling Bridge 2
Collected samples were given a unique identification number, which included the date, structure acronym (WO), element abbreviation (Pb) and sample number, logged onto a lead paint chip chain of custody form and shipped to an accredited laboratory for analysis. The bulk samples collected from the above listed materials (Table 1) were analyzed by Flame
Atomic Absorption (AA) via EPA SW-846 7420 and 3050B Method.
Analysis of the samples revealed that multiple suspect coatings contain lead in concentrations above the Detection Limit.
Laboratory results obtained are provided in detail in the attached laboratory report and summarized in the Table 2 below:
Limited Lead Paint Survey Results
Precision No.5269-20-0001-2AL
Table 2: Summary of Laboratory Results
Highest Lead
Concentration % by weight
Detection Limit
% by weight
1. White painted metal vertical safety beam Throughout 0.0065 0.0022
2. Gray painted metal main bridge stringer Throughout 0.0051 0.0031
3. Black painted metal vertical sheet piling Throughout 0.0021 0.0007
Based on the laboratory analysis, the following components associated with the structure are confirmed to be coated with lead based paint and shall be handled in accordance will all applicable regulations:
• All white painted metal vertical safety beams
• All gray painted metal main bridge stringers
• All black painted metal vertical sheet pilings
Vertical safety beam
Main bridge stringer
Vertical sheet pilings
Limited Lead Paint Survey Results
Precision No.5269-20-0001-2AL
Note: The white and black painted surfaces sampled are in deteriorated condition
Recommendations/Control Options
If renovation or demolition activities are to impact lead coated surfaces, all work should be conducted by workers trained in “lead safe work practices” as outlined by the Occupational Safety and Health Administration (OSHA). In addition, all lead coated components or paint removed from lead coated components should be disposed of in accordance with all
Federal, State, and Local regulations.
If additional materials not addressed during this inspection are to be disturbed, Precision strongly recommends that those materials either be assumed to be coated with lead based paint or that sampling is conducted to confirm the presence of absence of lead based paint prior to the disturbance of the materials.
If you have any questions or require additional information, please do not hesitate to contact me at (910) 763-3445
Sincerely, PRECISION ENVIRONMENTAL INC.
NC Lead Inspector/Risk Assessor #: 120097
Attachments: Paint Chip Sample Data and Chain of Custody
Laboratory Data Sheets
Laboratory and Inspector Certificates
Certificate of Analysis: Lead In Paint by EPA SW-846 7420 and 3050B*
Client Project :
557278
03/04/2020
03/04/2020
Date Reported :
Date Analyzed :
Date Received :
AAT Project :
Phone :
Email :
Fax :
jguetta@precision-enviro.com
910-763-3445
J. Guetta
Precision Environmental
Attn :
Client :
WHITE OAK BRIDGE NCProject Location :
5269-20-0001-2AL
Wilmington, NC 28403
3802 Cherry Ave.
3/5/2020 7:23:07AM
30105 Beverly Road
Romulus, MI 48174
Ph: 734-629-8161; Fax: 734-629-8431
Sampling Date : 02/28/2020
Lab Sample ID Result Lead
(% by weight) PPMSample DescriptionClient Code
Calculated R L
(% by weight)
22820-WO-PB-01 VERTICAL SAFETY BEAM WHITE5368781 65 0.0065 0.0022
22820-WO-PB-02 VERTICAL SAFETY BEAM WHITE5368782 66 0.0066 0.0006
22820-WO-PB-03 MAIN BRIDGE STRINGER GRAY5368783 35 0.0035 0.0024
22820-WO-PB-04 MAIN BRIDGE STRINGER GRAY5368784 51 0.0051 0.0031
22820-WO-PB-05 MAIN BRIDGE STRINGER GRAY5368785 67 0.0067 0.0015
22820-WO-PB-06 MAIN BRIDGE STRINGER GRAY5368786 99 0.0099 0.0013
22820-WO-PB-07 MAIN BRIDGE STRINGER GRAY5368787 <31 <0.0031 0.0031
22820-WO-PB-08 MAIN BRIDGE STRINGER GRAY5368788 41 0.0041 0.0006
22820-WO-PB-09 VERTICAL SHEET PILING BLACK5368789 23 0.0023 0.0006
22820-WO-PB-10 VERTICAL SHEET PILING5368790 21 0.0021 0.0007
Analyst Signature
Elyse Bidle
557278 AAT Project:Date Printed: 03/05/2020 7:23AM
RL= Reporting Limit * For true values assume (2) significant figures. The method and batch QC is acceptable unless otherwise stated. Current
EPA/HUD Interim Standard for lead in paint samples is: 5000 PPM (parts per million) or ug/g which is equivalent to 0.5% by weight. AAT internal sop
S203. The laboratory operates in accord with ISO 17025 guidelines and holds limited scopes of accreditation under AIHA-LAP and NY State DOH
ELAP programs. These results are submitted pursuant to AAT LLC current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions.Analytical results relate to the samples as received by the lab. AAT will not assume any liability or responsibility for the manner in which the results are used or interpreted. Reproduction of this document other than in its entirety is not permitted. All Quality control requirements for the samples this report contains have been met. AAT does not blank correct reported values. Sample data apply only to items analyzed. Samples are stored for 15 days following report date. *= Validated modified method
AIHA LAP- Lab ID #100986, NY State DOH ELAP -Lab ID #11864, State of Ohio- Lab ID # 10042
Precision EnvironmentalTo :
Attn :
Phone :
AAT Project :
Client Project :
Date Reported :
Project Location :
Email :J. Guetta
910-763-3445 jguetta@precision-enviro.com
557278
3/5/2020 7:23:07AM
5269-20-0001-2AL
WHITE OAK BRIDGE NC
3802 Cherry Ave.
Wilmington, NC 28403
30105 Beverly Road
Romulus, MI 48174
Ph: 734-629-8161; Fax: 734-629-8431
Sample CompletedAnalysis RequestedClient Code Analyst
5368781 03/04/2020Lead Paint22820-WO-PB-01 Elyse Bidle
5368782 03/04/2020Lead Paint22820-WO-PB-02 Elyse Bidle
5368783 03/04/2020Lead Paint22820-WO-PB-03 Elyse Bidle
5368784 03/04/2020Lead Paint22820-WO-PB-04 Elyse Bidle
5368785 03/04/2020Lead Paint22820-WO-PB-05 Elyse Bidle
5368786 03/04/2020Lead Paint22820-WO-PB-06 Elyse Bidle
5368787 03/04/2020Lead Paint22820-WO-PB-07 Elyse Bidle
5368788 03/04/2020Lead Paint22820-WO-PB-08 Elyse Bidle
5368789 03/04/2020Lead Paint22820-WO-PB-09 Elyse Bidle
5368790 03/04/2020Lead Paint22820-WO-PB-10 Elyse Bidle
Quality Assurance Coordinator - Stephen NorthcottReviewed By
557278 AAT Project:Date Printed: 03/05/2020 7:23AM
This report is intended for use solely by the individual or entity to which it is addressed. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify AAT immediately. Thank you.
AIHA LAP- Lab ID #100986, NY State DOH ELAP -Lab ID #11864, State of Ohio- Lab ID # 10042
3802 Cherry Ave. Wilmington, NC 28403 Tel: 910-763-3445 Fax: 910-763-3415 www.precision-enviro.com
Kimley-Horn
Attn: Scott Borges, PE
Re: Creosote Bulk Sampling & Analysis at:
White Oak Beach Bridge
White Oak, NC
PEI Project No.:5269-20-0001-2AL
Precision Environmental Inc. (Precision) was retained by Kimley-Horn to conduct a creosote survey and analysis of wood components associated with the above referenced structure. The inspection included all materials scheduled to be disturbed/removed during the upcoming demolition procedures.
The purpose of the survey was to determine if wood components associated with the structure are treated with creosote prior to upcoming demolition procedures.
The bulk sampling was performed by Precision’s representative Jonathan on February 28, 2020.
As a result, a total of two creosote treated components were identified. A listing of the identified components and the number of bulk samples collected per suspect material is provided in Table 1 below:
Table 1: Identified suspect LBP coatings materials
No. of Samples
Collected
1. Railroad Tie Upper bridge 2
2. Pylon Bridge structural support system 2
Collected samples were given a unique identification number, which included the date, structure acronym (WOB), and sample number, logged onto a creosote bulk chain of custody form and shipped to an accredited laboratory for analysis.
The bulk samples collected from the above listed materials (Table 1) were analyzed for creosote in bulk material via EPA
Method 8015D
Results
Analysis of the samples revealed that all components sampled contain creosote in levels above the reporting limit for the method.
Laboratory results obtained are provided in detail in the attached laboratory report and summarized in the Table 2 below:
Table 2: Summary of Laboratory Results
Highest
Concentration mg/Kg
Detection Limit
Mg/Kg
1. Railroad Tie Upper bridge 140,000 mg/Kg 47,000 mg/kg
2. Pylon Bridge structural support system 150,000 mg/Kg 42,000 mg/kg
White Oak Beach Bridge
Creosote Survey Results
Precision No.5269-20-0001-2AL
Recommendations/Control Options
Note: National Institute for Occupational Safety and Health (NIOSH) considers coal tar, coal tar pitch, and creosote to be coal tar products.
OSHA has not established a substance-specific standard for occupational exposure to coal tar pitch volatiles (CTPVs) however exposures are regulated under OSHA's air contaminants standard for general industry, shipyard employment and construction.
In addition, all creosote treated components should be disposed of in accordance with all Federal, State, and Local regulations.
All efforts were made to identify and access all components associated with the structure that are treated with creosote. If additional materials not addressed during this inspection are to be disturbed, Precision strongly recommends that those materials either be assumed to be treated with creosote or that sampling is conducted to confirm the presence of absence of creosote prior to the disturbance of the materials.
If you have any questions or require additional information, please do not hesitate to contact me at (910) 763-3445
Sincerely, PRECISION ENVIRONMENTAL INC.
Attachments: Creosote Sample Data and Chain of Custody
Laboratory Data Sheets
Railroad ties
Pylons
Phillip Worby, Environmental Chemistry Laboratory Director
Approved By:
Fax: (910) 763-3415 Phone: (910) 763-3445
The following analytical report covers the analysis performed on samples submitted to EMSL Analytical, Inc. on 3/3/2020. The results are tabulated on the attached data pages for the following client designated project:
Pre Demo Survey for White Oak Bridge 5269-20-0001-2AL
The reference number for these samples is EMSL Order #012002426. Please use this reference when calling about these samples. If you have any questions, please do not hesitate to contact me at (856) 303-2500.
3/13/2020Attn: Jonathan Guetta Precision Environmental Inc.
3802 Cherry Ave.
Wilmington, NC 28403
The test results contained within this report meet the requirements of NELAP and/or the specific certification program that is applicable, unless otherwise noted.
NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, CA ELAP 1877
The samples associated with this report were received in good condition unless otherwise noted. This report relates only to those items tested as received by the laboratory. The QC data associated with the sample results meet the recovery and precision requirements established by the NELAP, unless specifically indicated. All results for soil samples are reported on a dry weight basis, unless otherwise noted. This report may not be reproduced except in full and without written approval by EMSL Analytical, Inc.
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone: (856) 303-2500 Fax: (856) 858-4571 Email: EnvChemistry2@emsl.com
EMSL Analytical does not hold SHW certification in the state of North Carolina.
mailto:EnvChemistry2@emsl.com
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 858-4571 http://www.EMSL.com EnvChemistry2@emsl.com
012002426 CustomerID: PREN34 CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Jonathan Guetta Precision Environmental Inc.
3802 Cherry Ave.
Wilmington, NC 28403
Received: 03/03/20 9:40 AM
Pre Demo Survey for White Oak Bridge 5269-20-0001-2AL
Fax: (910) 763-3415 Phone: (910) 763-3445
Project:
Client Sample Description Lab ID:022829-WOB-01 012002426-0001 Railroad Tie
Collected: 2/28/2020
Method Parameter Result Units Analysis
Date & AnalystRL Prep
Date & Analyst
GC-SVOA
8015D Modified Creosote AC130000 mg/Kg 03/11/20 0:0047000 3/5/2020 AF
Client Sample Description Lab ID:022829-WOB-02 012002426-0002 Railroad Tie
Collected: 2/28/2020
Method Parameter Result Units Analysis
Date & AnalystRL Prep
Date & Analyst
GC-SVOA
8015D Modified Creosote AC140000 mg/Kg 03/11/20 0:0047000 3/5/2020 AF
Client Sample Description Lab ID:022829-WOB-03 012002426-0003 Pylon
Collected: 2/28/2020
Method Parameter Result Units Analysis
Date & AnalystRL Prep
Date & Analyst
GC-SVOA
8015D Modified Creosote AC140000 mg/Kg 03/11/20 0:0038000 3/5/2020 AF
Client Sample Description Lab ID:022829-WOB-04 012002426-0004 Pylon
Collected: 2/28/2020
Method Parameter Result Units Analysis
Date & AnalystRL Prep
Date & Analyst
GC-SVOA
8015D Modified Creosote AC150000 mg/Kg 03/11/20 0:0042000 3/5/2020 AF
MDL - method detection limit J - Result was below the reporting limit, but at or above the MDL ND - indicates that the analyte was not detected at the reporting limit RL - Reporting Limit (Analytical) D - Dilution Sample required a dilution which was used to calculate final results
Definitions:
Page 2 of 2ChemSmplw/RDL/NELAC-7.52.0 Printed: 3/13/2020 10:06:47 AM http://www.EMSL.com mailto:EnvChemistry2@emsl.com
OrderID: 012002426
A
IH
A
L ab o ra to ry
A cc re d it at io n
P ro g ra m s, L L
C a ck n o w le d g es t h t cc u ra te A n a ly ti ca l
T es ti n g L
B ev er ly R o ad
R o m u lu s M
I ab o ra to ry
I D al o n g w it h a ll p re m is es f ro m w h ic h k e y a ct iv it ie s ar e p er fo rm ed as l is te d a b o v e, h as f u lf il le d t h e re q u ir e m en ts o f th e
A
IH
A L ab o ra to ry A cc re d it at io n
P ro g ra m s
(A
IH
A -L
A P
L
L C a cc re d it at io n t o t h e
IS
O
/I E
C
:2 i n te rn at io n al s ta n d ar d
G en er a l R eq u ir em en ts f o r th e C o m p et en ce o f
T es ti n g a d li b ra ti o n
L a b o ra to ri es i n t h e fo ll o w in g
B O
R A
T O
R Y
A C
C R
E D
IT
A
T
IO
N P
R O
G R
A M
S
IN
D
U S
T R
IA
L
H Y
G
IE
N E re d it at io n E x p ir es
V
IR
O N
M E
N T
A L
L E re d it at io n E x p ir es
A u g u st
V
IR
O N
M E
N T
A L
M
IC
R O
B
IO
L O
G Y re d it at io n E x p ir
F O
O re d it at io n E x p ir
U
IQ
U
E S
C O
P re d it at io n E x p ir p ec if ic F ie ld
(s o f
T es ti n g
F o
T
M et h o d (s w it h in e ac h A cc re d it at io n P ro g ra m f o r w h ic h t h e ab o v e n a m ed l ab o ra to ry m ai n ta in s ac cr ed it at io n i s o u tl in ed o n t h e at ta ch ed
S co p e o f A cc re d it a ti o n
C o n ti n u ed a cc re d it at io n i s co n ti n g en t u p o n s u cc e ss fu l o n -g o in g c o m p li a n ce w it h I
S O
/I E
C
:2 an d
A
IH
A -L
A P
L
L C r eq u ir e m en ts
T h is c er ti fi ca te i s n o t v al id w it h o u t th e at ta ch ed
S c o p e o f
A cc re d it a ti o n
P le as e re v ie w t h e
A
IH
A -L
A P
L w eb si te w w w
.a ih aa cc re d it ed la b s.
o rg fo r th e m o st c u rr en t
S co p e.
li za b et h
B ir h a ir p er so n
A n a ly ti ca l
A cc re d it a ti o n B o rd h er yl
O
M o rt o
M n a g in g D ir ec to r, A
IH
A L a b o ra to ry
A cc re d it a ti o n P ro g ra m s, L
R ev is io n
/1
/2 at e Is su ed
/3
/2 http://www.aihaaccreditedlabs.org/
Effective: 10/14/2016
Scope_ELLAP_R7
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
Accurate Analytical Testing, LLC Laboratory ID: 100986
30105 Beverly Road, Romulus, MI 48174 Issue Date: 08/30/2019
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
The EPA recognizes the AIHA-LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory
Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air and composited wipes analyses are not included as part of the NLLAP.
Environmental Lead Laboratory Accreditation Program (ELLAP)
Initial Accreditation Date: 02/01/2004
A complete listing of currently accredited Environmental Lead laboratories is available on the AIHA-LAP, LLC website at:
http://www.aihaaccreditedlabs.org
Field of Testing (FoT) Technology sub-type/
Detector Method
Method Description (for internal methods only)
Paint
EPA SW-846 3050B (Mod)
EPA SW-846 7000
EPA SW-846 7420
Soil
EPA SW-846 3050B (Mod)
EPA SW-846 7000
EPA SW-846 7420
Settled Dust by Wipe
EPA SW-846 7000
NIOSH 7082
Airborne Dust
EPA SW-846 7000
NIOSH 7082