1629197dwgVol3_Sheet427-494_F.pdf
PDF 11 MB Posted
- Solicitation number
- N4008519R9186
About this file
This solicitation is for the design and construction of a new Underwater Launch Test Facility to support submerged launch testing and evaluation of full-scale launch technologies. Key details include:
-
The project involves construction of an Underwater Launch Pit, Operational Support Building, Warehouse Building, Water Treatment Facility, and Mechanical and Electrical Building to support testing. Supporting site work includes pavement, utilities and environmental mitigation.
-
Construction will be phased with initial site work and storage pad by month seven and beneficial occupancy by month eighteen after contract award. The solicitation requires responses by Jun 2020 from the Department of the Navy Naval Facilities Engineering Command.
-
The Operational Support Building will include a high bay area for vehicle maintenance and tool storage and a low bay for control centers, offices and other support spaces.
-
Utilities include water distribution and treatment for the launch pit, fire protection, sewer, electrical distribution and site lighting.
-
The scope requires design, construction services, equipment outfitting to support underwater launch testing and evaluation.
View the file
Other files
Show 40 more
Latest 50 of 115 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE ALARM
GENERAL NOTES ACU AUTONOMOUS CONTROL UNIT
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AVG AVERAGE
CA CLEAN AGENT
CO CONTRACTING OFFICER
COR CONTRACTING OFFICER REPRESENTATIVE
COTR CONTRACTING OFFICERS TECHNICAL REPRESENTATIVE
ELEV ELEVATION
EOL END OF LINE RESISTOR
FPC FIRE PUMP CONTROLLER
IDC INITIATING DEVICE CIRCUIT
MIN MINIMUM
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NP NOT PERMITTED
NTS NOT TO SCALE
QFPE QUALIFIED FIRE PROTECTION ENGINEER
SQFT SQUARE FEET
WP WEATHER PROOF
GENERAL NOTES ABBREVIATIONS
(ALL SYMBOLS AND ABBREVIATIONS SHOWN ARE NOT
NECESSARILY USED ON THE DRAWINGS)
A. THE FIRE ALARM SYSTEM SHALL BE DESIGNED, INSTALLED, AND COMMISSIONED IN
ACCORDANCE WITH THE FOLLOWING:
• INTERNATIONAL BUILDING CODE (IBC), (2015 EDITION)
• NFPA 72 (2019 EDITION)
• UFC 3-600-01 (CHANGE 3, MAY 2019)
B. THE CONTRACTOR SHALL RETAIN THE SERVICES OF A QUALIFIED FIRE PROTECTION ENGINEER
(QFPE) AS DEFINED BY UFC 3-600-01. THE QFPE SHALL BE RESPONSIBLE FOR THE DESIGN,
INSPECTION, AND TESTING OF THE FIRE PROTECTION SYSTEMS THROUGHOUT THE BUILDING.
C. THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE
UTILIZED AS GUIDANCE FOR THE PLANNING OF THE SYSTEM BY THE CONTRACTOR. PROVIDE
COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER OF RECORD AND
THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP
DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING
INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION
AND COMPLY WITH LOCAL CODES, AMENDMENTS AND BASE STANDARDS.
D. FOR COMPLETE SYSTEM CONTROL, REFER TO THE MATRIX OF OPERATIONS WITHIN THIS
PACKAGE.
E. PROVIDE A COMPLETE NEW FIRE ALARM SYSTEM WITH VOICE COMMUNICATION CAPABILITY
THROUGHOUT EACH BUILDING. A SINGLE FIRE ALARM CONTROL PANEL SHALL BE UTILIZED TO
SERVE EACH BUILDING. SYSTEM MUST BE COMPATIBLE WITH THE BASE STANDARD SIGNAL
COMMUNICATIONS DTX - 16 ZONE 141.0 MHZ SYSTEM.
F. FINAL FIRE ALARM SYSTEM TEST SHALL BE WITNESSED BY THE QFPE. FILE A "RECORD OF
COMPLETION" PREPARED IN ACCORDANCE WITH NFPA 72, RECORDS OF TESTING AND
INSPECTION AS WELL AS ALL ITEMS REQUIRED BY SPECIFICATION 28 31 63.00 20, AND THE FIRE
ALARM TEST REPORT WITH THE AHJ.
G. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES SHALL NOT EXCEED 2 FLASHES PER
SECOND, NOR BE LESS THAN 1 FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A
MAXIMUM PULSE DURATION SHALL BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40%, IN
ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES SHALL BE SPACED IN
ACCORDANCE WITH NFPA 72. ALL STROBES SHALL BE SYNCHRONIZED.
H. AUDIBLE FIRE ALARM SOUND LEVELS SHALL BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST
60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE
OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE
FROM THE AUDILE APPLIANCE. PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT
THE FACILITY TO MEET THE NFPA 72 REQUIREMENTS. AUDIBILITY THROUGHOUT THE BUILDING
SHALL BE MET WITH ALL DOORS, SHUTTERS, PARTITIONS, ETC. CLOSED.
I. SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES SHALL BE INSTALLED UNDER
SPECIFICATION SECTION 21 13 13.00 20. CONNECT DEVICES TO THE FIRE ALARM SIGNALING LINE
CIRCUITS.
J. OBTAIN APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.
K. DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER THAN 3 FEET FROM AN AIR SUPPLY OR
RETURN DIFFUSER.
L. MOUNT ALL WALL-MOUNTED VISUAL AND VISUAL/AUDIBLE NOTIFICATION APPLIANCES WITH THE
ENTIRE STROBE LENS BETWEEN 80" TO 96" ABOVE THE FINISHED FLOOR.
M. FIRE ALARM CIRCUITS ARE TO BE CLASS B. T-TAPS AND WIRE NUTS ARE NOT PERMITTED.
N. ALL DUCT SMOKE DETECTORS SHALL BE PROVIDED WITH A REMOTE TEST/INDICATOR SWITCH
ASSEMBLY. THE REMOTE ASSEMBLY SHALL BE LOCATED 5 FEET AFF.
O. PROVIDE SURGE SUPPRESSORS ON ALL EXTERIOR CIRCUITS AND ALL 120VAC POWER
CIRCUITS. SURGE SUPPRESSOR SHALL BE INSTALLED ON THE CIRCUIT WITHIN 3 FEET OF THE
POINT WHERE THE CIRCUIT ENTERS OR LEAVES THE BUILDING.
P. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINE DESIGNS.
SYMBOLS - PANEL
SYMBOL DESCRIPTION
MONITOR MODULE
SYMBOLS - MISCELLANEOUS
SYMBOL DESCRIPTION
MANUAL PULL STATION
SYMBOLS - INITIATING
S,R
ID
P,I,ASD
SMOKE DETECTOR
P = PHOTOELECTRIC
I = IONIZATION
ASD = AIR SAMPLING DETECTOR
DUCT DETECTOR
ID = FAN UNIT DESIGNATION
S = SUPPLY
R = RETURN
MM
CONTROL MODULECM
TAMPER SWITCH
C WATER FLOW SWITCH
TS
WF
SYMBOL DESCRIPTION
FACP FIRE ALARM CONTROL PANEL
ANN ANNUNCIATOR PANEL
RADIO ALARM TRANSMITTER (SIGNAL COMMUNICATIONS DTX-16
TRANSCEIVER)
NOTIFICATION APPLIANCE CONTROL PANEL
RAT
NAC
F
SURGE SUPPRESSORSS
SYMBOL DESCRIPTION
FIRE ALARM SPEAKER / STROBE
(CEILING-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
SYMBOLS - NOTIFICATION
#CD
SPEAKER (WALL-MOUNTED, UNLESS OTHERWISE NOTED)
WP = WEATHER PROOF
WP
FIRE ALARM STROBE
(CEILING-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
#CD
FIRE ALARM STROBE
(WALL-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
FIRE ALARM SPEAKER/STROBE
(WALL-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING, WP = WEATHER PROOF
SPEAKER (CEILING-MOUNTED, UNLESS OTHERWISE NOTED)
WP = WEATHER PROOFWP
#CD
#CD
FIXED TEMPERATURE HEAT DETECTOR (165 DEGREE F)
END OF LINE RESISTOR
C
PRESSURE SWITCH
LOW AIR PRESSURE SWITCH
C
PS
C
LAP
WP
FADC FIRE ALARM DOCUMENT CABINET
HORN (WALL-MOUNTED, UNLESS OTHERWISE NOTED)
WP = WEATHER PROOF
WP
F
#CD
HORN/STROBE (WALL-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
NTS
/2
/2
:3
:3 A
M
OSB-FA001
742427
C R
A N
E
IN
D
IA
N
A
12810936
N40085-19-R-9186
JCM WTE MC
F
IR
E A
L A
R M
G E
N E
R A
L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
A
F
IR
E A
L A
R M
G E
N E
R A
L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
RDS/PJB
DSN
EJA
1629197
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
F F
F A
C P
C
WF
C
TS
15 30
15 15
F
P P
P
P P
F
MM MM
CM CM
CM
F
F A
D C
R A
T
C
TS
P
A
B
C
D
E
A.8
D.2
JAN. CL
LCC EQUIPMENT
ROOM
CONFERENCE ROOM
INSTRUMENTATION
ROOM
OFFICE
OFFICE
OFFICE
CLOSET
BREAK ROOM
LAUNCH CONTROL
CENTER
LTV & CANISTER
MAINTENANCE AREA
CORRIDOR
1 1
AHU-01 (SUPPLY) AHU-02 (SUPPLY)
AHU-03 (SUPPLY)
2 2
W P 3
A
B
C
D
E
A.8
D.2
STORAGE
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
1/8" = 1'-0"
/2
/2
:3
:3 A
M
OSB-FA101
742428
C R
A N
E
IN
D
IA
N
A
12810937
N40085-19-R-9186
JCM WTE MC
F
IR
E A
L A
R M
F L O
O R
P L A
N S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
A
F
IR
E A
L A
R M
F L O
O R
P L A
N S
RDS/PJB
DSN
EJA
1629197
1/8" = 1'-0"A1
FIRE ALARM FIRST FLOOR PLAN
1/8" = 1'-0"A4
FIRE ALARM MEZZANINE PLAN
A. REFER TO SHEET OSB-FA001 FOR FIRE ALARM GENERAL NOTES,
SYMBOLS, AND ABBREVIATIONS.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
COORDINATION WITH LIGHTS, MECHANICAL DIFFUSERS, AND
CEILING GRID.
C. REFER TO UTF-ES101 THRU UTF-ES305 FOR DUCT BANK LAYOUT
AND SECTIONS.
1 INSTALL THREE (3) SMOKE DETECTORS IN THE LOCATION SHOWN:
UNDERFLOOR, CEILING, AND ABOVE CEILING.
2 PROVIDE ADDRESSABLE CONTROL MODULE FOR INTERFACE WITH
DUCT SMOKE DETECTOR.
3 WEATHERPROOF HORN SHALL ACTIVATE UPON WATER FLOW.
4 PROVIDE FIRE ALARM DOCUMENT CABINET IN ACCORDANCE WITH
NFPA 72. INSERT FIRE ALARM SYSTEM DOCUMENTATION WITHIN
CABINET.
5 PROVIDE RADIO ALARM ANTENNAE ON SIDE OF OSB. CONTRACTOR
TO CONFIRM FINAL LOCATION AFTER TESTING FOR OPTIMAL
SIGNAL.
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
GENERAL SHEET NOTES
SHEET KEYNOTES#
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
CONDUIT FROM
PREVIOUS DEVICES
CONDUIT TO
REMAINING DEVICES
FIRE ALARM NOTIFICATION
APPLIANCE LOCATION ZONE
(AUDIBLE ONLY APPLIANCES
SHALL BE MOUNTED NOT LESS
THAN 90" AFF AND NOT LESSTHAN
6" BELOW THE FINISHED CEILING)
FINISHED FLOOR
FINISHED CEILING
(WHERE PROVIDED)
A
FF
A
FF
A
FF
FIRE
SIGNALING LINE AND
NOTIFICATION APPLIANCE
CIRCUIT CONDUIT
(SINGLE CONDUIT, WHEN
PERMITTED BY MANUFACTURER)
MAXIMUM HORIZONTAL
DISTANCE TO EXIT IS 5
FEET
MOUNTED PULL
STATION AND
BACKBOX
JUNCTION BOX
DETECTOR BASE
SMOKE
EXPOSED CEILING
DETECTOR
J-BOX ON
3/4" EMT CONDUIT
SMOKE
MEMBER
STRUCTURAL
MASTER
FACP
(6) 15 (2)
(3) 30 (2)
OSB NOTIFICATION - STROBES
OSB NOTIFICATION - SPEAKERS
OSB SIGNALING LINE CIRCUIT
BATTERY
120 VAC
F P
(12) (4)
MM
C
TS
MM
C
WF
(1) (1)
(1)
SS
FIRE ALARM NETWORK TO
NEXT FACP
SS
FIRE ALARM NETWORK TO
NEXT FACP
RAT
DROP CEILING TILE
DETECTOR BASE
SMOKE
4"x4"x2-1/8" J-BOX
J-BOX ON FLOOR SLAB
SMOKE DETECTOR
1/2" FLEX WITH FIRE DETECTION
CIRCUITS. FLEXIBLE CONNECTION
MAY NOT EXCEED 6 FEET AND MAY
NOT BE EXPOSED.
"T" BAR TYPE HANGER
3/4" EMT CONDUIT
MASTER
FACP
FACP
FACP
RAT
SS
SS
SS
SS
SSSS
OSB
WHS
FIRE PUMP
BUILDING
FACP
FACP
SS
SS
SS
SS
MEB
WTB
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
NTS
/2
/2
:3
:4 A
M
OSB-FA501
742429
C R
A N
E
IN
D
IA
N
A
12810938
N40085-19-R-9186
JCM WTE MC
F
IR
E A
L A
R M
D E
T A
IL
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
A
F
IR
E A
L A
R M
D E
T A
IL
S
RDS/PJB
DSN
EJA
1629197
NTSB1
FIRE ALARM MOUNTING DETAIL
NTSD1
EXPOSED CEILING DETECTOR DETAIL
NTSA3
OSB FIRE ALARM RISER DIAGRAM
NOT TO SCALEA1
SUSPENDED CEILING DETECTOR DETAIL
NTSB3
FIRE ALARM NETWORK DIAGRAM
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
CONTROL UNIT
ANNUNCIATION NOTIFICATION
LIFE SAFETY
CONTROL
B U
IL
D
IN
G
F A
C P
A L A
R M
L E
D A
N D
A U
D
IB
L E
S
IG
N A
L
B U
IL
D
IN
G
F A
C P
S U
P E
R V
IS
O
R Y
L E
D A
N D
A U
D
IB
L E
S
IG
N A
L
B U
IL
D
IN
G
F A
C P
T R
O U
B L E
L E
D A
N D
A U
D
IB
L E
S
IG
N A
L
T R
A N
S M
IT
A
L A
R M
S
IG
N A
L T
O B
A S
E C
E N
T R
A L S
T A
T
IO
N M
O N
IT
O
R
IN
G S
T A
T
IO
N
T R
A N
S M
IT
S
U P
E R
V
IS
O R
Y S
IG
N
A L T
O B
A S
E C
E N
T R
A L M
O N
IT
O
R
IN
G S
T A
T
IO
N
T R
A N
S M
IT
T
R O
U B
L E
S
IG
N A
L T
O B
A S
E C
E N
T R
A L M
O N
IT
O
R
IN
G S
T A
T
IO
N
A C
T
IV
A T E
F
IR
E A
L A
R M
A U
D
IB
L E
A N
D V
IS
U
A L N
O T
IF
IC
A
T
IO
N A
P P
L
IA
N C
E S
W
IT
H
IN
B U
IL
D
IN
G
SYSTEM OUTPUTS
MANUAL FIRE ALARM PULL STATION
SYSTEM INPUT
AREA SMOKE DETECTOR2
A B C D E F G H I J K L M N O P Q R S T U
A B C D E F G H I J K L M N O P Q R S T U
INDICATES ACTION WILL CAUSE A SPECIFIC RESULT
EMPTY SQUARE INDICATES ACTION WILL NOT CAUSE A SPECIFIC RESULT
V
V W
W
D E
A C
T
IV
A T E
P U
B L
IC
A D
D R
E S
S S
Y S
T E
M
DUCT SMOKE DETECTOR
WATER FLOW SWITCH
VALVE TAMPER SWITCH
PANEL AC POWER FAIL
PANEL LOW BATTERY
OPEN CIRCUIT
GROUND FAULT
SHORT CIRCUIT
12 PANEL TROUBLE
S H
U T D
O W
N A
S S
O C
IA
T E
D H
V A
C U
N
IT
18 ---
A C
T
IV
A T E
F
IR
E A
L A
R M
A U
D
IB
L E
A N
D V
IS
U
A L N
O T
IF
IC
A
T
IO
N A
P P
L
IA
N C
E S
O N
B U
IL
D
IN
G
E X
T E
R
IO
R
RAT
ANTENNA
BATTERY
120 VAC
SPARE
SPARE
SPARE
SPARE
MEB ALARM SS
MEB TROUBLE SS
MEB SUPERVISORY SS
FPE ALARM SS
OSB ALARM
OSB TROUBLE
OSB SUPERVISORYSS SS SS SS SS SS SS SS SS
WHS TROUBLESS
WHS SUPERVISORYSS
WTB ALARMSS
WTB TROUBLESS
WHS ALARMSS
WTB SUPERVISORYSS
SSSS SS
FPE TROUBLE SS
FPE SUPERVISORY SS
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
NTS
/2
/2
:3
:4 A
M
OSB-FA502
742430
C R
A N
E
IN
D
IA
N
A
12810939
N40085-19-R-9186
JCM WTE MC
F
IR
E A
L A
R M
M A
T R
IX
O
F O
P E
R A
T
IO
N S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
A
F
IR
E A
L A
R M
M A
T R
IX
O
F O
P E
R A
T
IO
N S
RDS/PJB
DSN
EJA
1629197
NTSA1
FIRE ALARM MATRIX OF OPERATIONS
NTSA3
RADIO ALARM TRANSMITTER (RAT) RISER
DIAGRAM
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
SPRINKLER DESIGN CRITERIA
HAZARD
CLASSIFICATION
DENSITY
REQUIREMENTS
DURATION
OF
SUPPLY
MAXIMUM
SPRINKLER
PROTECTION AREA
SPRINKLER
TEMPERATURE
WATERFLOW TEST DATA
TEST DATE: MARCH 27, 2019
STATIC PRESSURE: 104 PSI
RESIDUAL PRESSURE: 81 PSI
1453 GPMDISCHARGE FLOW:
HOSE
ALLOWANCE
60 MIN.
ORDINARY
0.20 GPM/SQFT OVER
MOST REMOTE 2,500 SQFT
130 SQFT ORDINARY 250 GPM
GAUGE HYDRANT # AND LOCATION: GAUGE HYDRANT #1124
FLOW HYDRANT #1201FLOW HYDRANT # AND LOCATION:
K-FACTOR
8.0
60 MIN.
LIGHT
0.10 GPM/SQFT OVER
MOST REMOTE 1,500 SQFT
225 SQFT ORDINARY 250 GPM5.6
GENERAL NOTES AND SYMBOLS
PIPING SYMBOLS
FIRE SPRINKLER SYMBOLS
DIRECTION OF SLOPE DOWN
PRESSURE CONTROL VALVE
TEST PORT
RELIEF VALVE
GATE VALVE
CHECK VALVE
ECCENTRIC REDUCER
TEE OUTLET DOWN
TEE OUTLET UP
CONCENTRIC REDUCER
UNION
FIRE SPRINKLER NOTES
ELBOW DOWN
VALVE IN DROP
VALVE IN CENTER DROP
VALVE IN RISE
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
DIRECTION OF FLOW
ELBOW UP
A. PROVIDE COMPLETE WET PIPE FIRE SPRINKLER SYSTEMS FOR
THE ENTIRE BUILDING AND A DRY-PIPE SYSTEM FOR THE
CANOPY DESIGNED AND INSTALLED IN ACCORDANCE WITH UFC
3-600-01 WITH CHANGE 3 (MAY 2019), IBC (2015 EDITION), AND
NFPA 13 (2019 EDITION).
B. THE CONTRACTOR SHALL RETAIN THE SERVICES OF A
QUALIFIED FIRE PROTECTION ENGINEER (QFPE) AS DEFINED BY
UFC 3-600-01. THE QFPE SHALL BE RESPONSIBLE FOR THE
DESIGN, INSPECTION, AND TESTING OF THE FIRE PROTECTION
SYSTEMS THROUGHOUT THE BUILDING.
C. VERIFY ALL LOCATIONS AND MEASUREMENTS AS CONDITIONS
MAY VARY THROUGHOUT CONSTRUCTION. ALL CHANGES FROM
THE ORIGINAL DESIGN MUST BE APPROVED BY THE QFPE.
D. SPRINKLER CONTRACTOR SHALL INSTALL TAMPER AND FLOW
SWITCHES. CONNECTIONS TO THE FIRE ALARM SYSTEM'S
SIGNALING LINE CIRCUIT SHALL BE MADE UNDER
SPECIFICATION DIVISION 28.
E. SPRINKLER CONTRACTOR SHALL UTILIZE FLOW DATA
PROVIDED TO BASE HYDRAULIC CALCULATIONS AND SIZE
PIPING. IF THE TEST RESULTS ARE OVER SIX MONTHS OLD,
SPRINKLER CONTRACTOR TO PERFORM A NEW HYDRANT FLOW
TEST.
F. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND
APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.
G. HYDRAULICALLY CALCULATE THE WET PIPE SPRINKLER
SYSTEMS PER NFPA 13 DENSITY AND SPACING LISTED IN THE
SPRINKLER DESIGN CRITERIA TABLE BELOW. FIELD VERIFY
SYSTEM DESIGN AND LAYOUT PRIOR TO FABRICATION OR
INSTALLATION.
H. PROVIDE PIPE HANGERS ON ALL FIRE SPRINKLER SYSTEM
PIPING AND EQUIPMENT PER NFPA 13.
I. SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE
AND ROOM USE. SEE ARCHITECTURAL, ELECTRICAL,
MECHANICAL, AND TELECOMMUNICATIONS PLANS FOR THE
LOCATION OF ALL CEILING-MOUNTED DEVICES. FIELD VERIFY
AND COORDINATE THE LOCATIONS OF ALL SYSTEM
COMPONENTS INCLUDING PIPING, ALARMS, DRAINS, TEST
POINTS, ETC. WITH ARCHITECTURAL, STRUCTURAL,
MECHANICAL, AND ELECTRICAL EQUIPMENT WITHIN THE
BUILDING.
J. PROVIDE AUXILIARY DRAINAGE WITH A DRAIN VALVE AND PLUG
FOR ALL TRAPPED SECTION OF PIPE, AS REQUIRED BY NFPA 13.
K. THESE DOCUMENTS DEPICT PERFORMANCE LEVEL
ENGINEERING DESIGN CRITERIA TO BE UTILIZED AS GUIDANCE
FOR THE PLANNING OF THE FIRE SPRINKLER SYSTEM BY THE
CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW
AND APPROVAL FROM THE ENGINEER OF RECORD AND AHJ
PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS
AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY
TO PROVIDE A COMPLETE INSTALLATION.
L. PIPE MAIN DRAIN TO OUTSIDE OF BUILDING. PROVIDE SPLASH
BLOCK AS NECESSARY.
M. SPRINKLER SYSTEM DESIGN SHALL BE BASED ON THE RESULTS
OF THE WATER FLOW TEST AND OPERATION OF THE SITE FIRE
PUMP. FIRE PUMP SHALL BE RATED FOR 1,500 GPM @ 50 PSI.
N. BUILDING IS SEISMIC DESIGN CATEGORY C. REFER TO
STRUCTURAL DRAWINGS FOR DESIGN CRITERIA. SEISMIC
BRACING AND RESTRAINT OF BRANCH LINES SHALL BE
DESIGNED AND INSTALLED FOR ALL SPRINKLER PIPING IN
ACCORDANCE WITH NFPA 13 AND NFPA 13 ANNEX'S. BRANCH
LINES ARE REQUIRED TO BE RESTRAINED AGAINST EXCESSIVE
MOVEMENT, BOTH VERTICALLY AND LATERALLY (HORIZONTAL)
PER NFPA 13 EARTHQUAKE BRACING.
O. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINE DESIGNS.
PRESSURE GAUGE WITH
GAUGE COCK
STRAINER WITH
BLOWDOWN VALVE
SYSTEM RISER
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AVG AVERAGE
BFP DOUBLE CHECK BACKFLOW PREVENTER
CFM CUBIC FEET PER MINUTE
CO CONTRACTING OFFICER
COTR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
ELEV ELEVATION
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FHV FIRE HOSE VALVE
FP FIRE PUMP
FPC FIRE PUMP CONTROLLER
FVC FIRE VALVE CABINET
GALS GALLONS
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GV GATE VALVE
JP JOCKEY PUMP
MIN MINIMUM
NC NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NP NOT PERMITTED
NTS NOT TO SCALE
OS&Y OUTSIDE SCREW & YOKE
PSIG POUNDS PER SQUARE INCH GAUGE
SOV SOLENOID VALVE
SQFT SQUARE FEET
UH UNIT HEATER
VLV VALVE
FLOW SWITCH
LH
OH
EH
LIGHT HAZARD OCCUPANCY
ORDINARY HAZARD OCCUPANCY
EXTRA HAZARD OCCUPANCY
UPRIGHT SPRINKLER
TC INSPECTOR'S TEST / DRAIN CONNECTION
COMBINED WALL MOUNTED FIRE
PUMP AND BACKFLOW PREVENTER
TEST CONNECTION WITH SIX 2-1/2"
VALVES
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
NTS
/2
/2
:3
:4 A
M
OSB-FX001
742431
C R
A N
E
IN
D
IA
N
A
12810940
N40085-19-R-9186
JCM WTE MC
F
IR
E S
U P
P R
E S
S
IO
N G
E N
E R
A L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
X
F
IR
E S
U P
P R
E S
S
IO
N G
E N
E R
A L
N O
T E
S
S Y
M B
O L S
A
N D
A B
B R
E V
IA
T
IO
N
S
RDS/PJB
DSN
EJA
1629197
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
A
B
C
D
E
A.8
D.2
ELECTRICAL ROOM
COMMUNICATIONS
ROOM
JAN. CL
UNISEX TLT
LCC EQUIPMENT
ROOM
CONFERENCE ROOM
INSTRUMENTATION
ROOM
OFFICE
OFFICE
OFFICE
CLOSET
BREAK ROOM
LAUNCH CONTROL
CENTER
UNISEX TLT
LTV & CANISTER
MAINTENANCE AREA
CORRIDOR
1 2
6"ø
6"ø
6"ø
6"ø
6"ø
6"ø
6"ø
6"ø
OH
OH
OH OH
OH
OH
LH LH
LH
LH
LH
LH
LH
LH
LH
A
B
C
D
E
A.8
D.2
OH
STORAGE
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
1/8" = 1'-0"
/2
/2
:3
:4 A
M
OSB-FX101
742432
C R
A N
E
IN
D
IA
N
A
12810941
N40085-19-R-9186
JCM WTE MC
F
IR
E S
U P
P R
E S
S
IO
N F
L O
O R
P L A
N S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
X
F
IR
E S
U P
P R
E S
S
IO
N F
L O
O R
P L A
N S
RDS/PJB
DSN
EJA
1629197
1/8" = 1'-0"A1
FIRE SUPPRESSION FIRST FLOOR PLAN
PLAN NORTH
8'4' 16'0
SCALE: 1/8"=1'-0"
A. REFER TO SHEET OSB-FX001 FOR FIRE SUPPRESSION GENERAL
NOTES, SYMBOLS, AND ABBREVIATIONS.
B. WET-PIPE SPRINKLER COVERAGE IS PROVIDED UNLESS NOTED
OTHERWISE.
C. NO PIPING TO BE INSTALLED OVER TOP OF ELECTRICAL OR
TELECOMMUNICATION EQUIPMENT.
D. REFER TO UTF-CS109 THRU UTF-CS110 FOR EXISTING HYDRANTS
1124 AND 1201 FLOW TEST INFORMATION.
1 FIRE DEPARTMENT CONNECTION
2 INSPECTOR'S TEST / DRAIN CONNECTION
3 PROVIDE A SEPARATE SPRINKLER ZONE FOR THE LAUNCH
CONTROL CENTER, INSTRUMENTATION ROOM, AND LCC
EQUIPMENT ROOM (BOUNDARIES INDICATED WITH DASHED LINE).
4 PROVIDE SAFETY STRIPING AROUND SPRINKLER RISER. REFER TO
ARCHITECTURAL SIGNAGE PLANS FOR DETAILS.
5 PROVIDE A CONTROL VALVE WITH TAMPER SWITCH, CHECK VALVE,
AND WATER FLOW SWITCH ON SEPARATE SPRINKLER FEED TO
LAUNCH CONTROL CENTER, INSTRUMENTATION ROOM, AND LCC
EQUIPMENT ROOM.
1/8" = 1'-0"A4
FIRE SUPPRESSION MEZZANINE PLAN
GENERAL SHEET NOTES
SHEET KEYNOTES#
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
RETAINER
ALL THREAD
PIPE RING
ROD
WITH LOCKNUT
BEAM CLAMP
STRAP
MEMBER
STRUCTURAL
KEY NOTES
SPARE SPRINKLER CABINET
GATE VALVE
CHECK VALVE
WATER FLOW INDICATOR
FIRE DEPARTMENT CONNECTION
INSPECTOR'S TEST/DRAIN CONNECTION
3 4
TO DRAIN
TO SYSTEM
TC
BACKFILL
U N
D E
R C
O M
P A
C T
E D
S O
IL
UNDERGROUND
TERMINATES IN
FLANGED SPIGOT
PIECE
EXTERIOR
WALL
GRADE
DUCTILE IRON CEMENT LINED
UNDERGROUND DUCTILE
IRON CEMENT LINED PIPE.
CONCRETE THRUST
BLOCK TYP. AT ALL
INCOMING WATER
SERVICES. 10 SF
MINIMUM OF BEARING
SURFACE.
UNDERGROUND MAIN
SAND BACKFILL (TYP.)
M
IN
IM
U
M C
O V
E R
ROD PIPE-TYPICAL JOINT RESTRAINT AT ALL
INCOMING WATER SERVICES PER NFPA 24. COAT
WITH ASPHALT.
PROVIDE 2" ANNULAR SPACE
AROUND PIPE
THROUGH CONCRETE
SLAB AROUND DUCTILE
IRON PIPE. SPACE
SHALL BE FILLED WITH
A FLEXIBLE MASTIC
MATERIAL
3/4"Ø STEEL TIE RODS
BITUMASTIC COATED
CONCRETE
FLOOR
NOTE:
WORK 5'-0" OUTSIDE BUILDNG
BY SITE UTILITY
CONTRACTOR.
FLEXIBLE COUPLING
ARM OVER SHALL MEET
NFPA 13 CRITERIA
SPRINKLER MAIN
OR BRANCH LINE
SUSPENDED CEILING
RECESSED SPRINKLER
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
As indicated
/2
/2
:3
:4 A
M
OSB-FX501
742433
C R
A N
E
IN
D
IA
N
A
12810942
N40085-19-R-9186
JCM WTE MC
F
IR
E S
U P
P R
E S
S
IO
N D
E T
A
IL
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -F
X
F
IR
E S
U P
P R
E S
S
IO
N D
E T
A
IL
S
RDS/PJB
DSN
EJA
1629197
NTSB1
BEAM CLAMP HANGER DETAIL
NTSB4
FIRE SUPPRESSION RISER SCHEMATIC
DIAGRAM
A3
RISER 3D ISOMETRIC VIEW
NTSC2
FIRE WATER SERVICE DETAIL
NTSNTSA1
SPRINKLER ARM OVER DETAIL (TYPICAL)
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
XX
PLUMBING ABBREVIATIONS PLUMBING LEGEND AND SYMBOLS
SPECIAL INSPECTIONS
SYMBOL ABBREVIATION DESCRIPTION
PLUGGED PIPE/OUTLET
CONCENTRIC REDUCER
ECCENTRIC REDUCER
CAPPED PIPE/OUTLET
UNION
P/TRV
U
PRESSURE/TEMPERATURE RELIEF VALVE
HB/WH
SOV
FLEXIBLE PIPE CONNECTOR
HOSE BIBB / WALL HYDRANT
ANCHOR
WATER HAMMER ARRESTER
FLUID FLOW DIRECTION
WHA
GAS COCK
DOMESTIC HOT WATER RETURN LINEDHWR
THERMOMETER
NOTE: NOT ALL ABBREVIATIONS AND
SYMBOLS SHOWN HEREIN ARE UTILIZED.
CHECK VALVECV
TOP CONNECTION
BOTTOM CONNECTION
CO OR WCO CLEANOUT OR WALL CLEANOUT
FCO FLOOR CLEANOUT
COTG CLEANOUT TO GRADE
SHUT-OFF VALVE OR ISOLATION VALVE
BALANCING VALVE
PIPE UP OR DOWN BASED ON SYSTEM
PIPE ELBOW UP OR DOWN BASED ON SYSTEM FLOW
SANITARY SEWER/WASTE
EXPANSION JOINT
SQUARE FLOOR DRAIN OR SHOWER DRAIN
FLOOR SINK
KITCHEN EQUIPMENT TAG
BALL VALVE
DCW DOMESTIC COLD WATER SUPPLY
EQUIPMENT CALL OUT
DHW DOMESTIC HOT WATER SUPPLY
SANITARY SEWER/WASTE BELOW FLOOR/GRADE
NATURAL GASGASG
SS
WHEN THE CONTRACTOR IS REQUIRED BY THE GOVERNMENT TO PROVIDE SPECIAL INSPECTIONS AS PART OF THE WORK, THE CONTRACTOR SHALL RETAIN THIRD-PARTY QUALITY ASSURANCE AGENCIES TO CONDUCT THE SPECIAL INSPECTIONS REQUIRED BY THE IBC. THESE INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE ICC IBC 2018 AND THE DESIGN DOCUMENTS. THE INSPECTING AGENCY SHALL PROVIDE REPORTS OF THE SPECIAL INSPECTIONS DIRECTLY TO THE GOVERNMENT. REFER TO SPECIAL
INSPECTIONS SPECIFICATION SECTIONS FOR DEFINITIONS AND ADDITIONAL REQUIREMENTS.
GREASE WASTE
1. PROVIDE LABOR AND MATERIALS TO DELIVER COMPLETE AND PROPERLY FUNCTIONING PLUMBING SYSTEMS.
2. PROVIDE PLUMBING WORK IN ACCORDANCE WITH CONTRACT SPECIFICATIONS, IPC 2018, UFC REQUIREMENTS, AND APPLICABLE
LOCAL CODES.
3. COORDINATE PLUMBING WORK WITH SITE CONDITIONS AND WORK OF OTHER TRADES. VERIFY SLOPES AND INVERT ELEVATIONS
PRIOR TO COMMENCEMENT OF WORK.
4. FURNISH MATERIALS, CUTTING, PATCHING, ADAPTING AND OTHER INCIDENTAL WORK, TOGETHER WITH SUCH TEMPORARY
CONNECTIONS AS MAY BE REQUIRED.
5. PROVIDE PIPE PENETRATIONS THROUGH FLOOR SLAB AND WALLS WITH PIPE SLEEVES.
6. PROVIDE ACCESS PANELS FOR VALVES, WATER HAMMER ARRESTERS AND OTHER PLUMBING SPECIALTIES LOCATED INSIDE CHASES, BEHIND WALLS OR ABOVE INACCESSIBLE CEILING. COORDINATE EXACT LOCATIONS AND FINISHES OF ACCESS PANELS WITH
ARCHITECTURAL DRAWINGS.
7. PROVIDE SECONDARY STRUCTURAL STEEL MEMBERS FOR PIPING AND EQUIPMENT SUPPORTS. PROVIDE BOLTING AND WELDING OF SUPPORTS PER CONTRACT STRUCTURAL SPECIFICATIONS. SUBMIT SHOP DRAWINGS FOR GOVERNMENT APPROVAL.
8. VENT ROOF PENETRATIONS SHALL BE A MINIMUM OF 15 FT. HORIZONTALLY AWAY FROM THE ROOF EDGE AND AIR INTAKES.
9. PROVIDE FIRE STOPPING FOR PIPING CROSSING FIRE-RATED BARRIERS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED
BARRIER LOCATIONS.
10. MOUNT ALL OVERHEAD UTILITIES AND OTHER FIXTURES WEIGHING 31 POUNDS OR MORE (EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS THAT COLLECTIVELY EXCEED THAT WEIGHT) TO MINIMIZE THE LIKELIHOOD THAT THEY WILL FALL AND INJURE BUILDING OCCUPANTS. DESIGN ALL EQUIPMENT MOUNTINGS TO RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION. THIS STANDARD DOES NOT PRECLUDE THE NEED TO DESIGN EQUIPMENT MOUNTINGS FOR FORCES REQUIRED BY OTHER CRITERIA SUCH AS SEISMIC
STANDARDS.
11. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINE DESIGNS.
VENT
SS
GW
GW GREASE WASTE BELOW FLOOR/GRADE
KEYED NOTEXX
ROUND FLOOR DRAIN OR SHOWER DRAIN
CONDENSATE DRAINCD
R RADON
V
FC FAN COIL
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FFE, F.F.E. FINISH FLOOR ELEVATION
FIN FLR ELEV
FGE, F.G.E. FINISH GRADE ELEVATION
FIN GRADE ELEV
FIN FINISH
FLA FULL LOAD AMPS
FLR FLOOR
FP FIRE PROTECTION
FS FLOOR SINK
FWD FOOD WASTE DISPOSER
G NATURAL GAS
GA GAUGE, GAGE
GALV GALVANIZED
GPR GAS PRESSURE REGULATOR
GW GREASE WASTE
H HEIGHT
HB HOSE BIBB
HD HEAD
HORIZ HORIZONTAL
HP HORSEPOWER
HR HOSE REEL
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HZ HERTZ
ID INSIDE DIAMETER
IE, I.E. INVERT ELEVATION
IT INFORMATION TECHNOLOGY
J JOULE
K KELVIN
kCAL/HR KILOCALORIES PER HOUR kG KILOGRAM kG/SQ CM KILOGRAM PER SQUARE CENTIMETER kG/SM KILOGRAM PER SQUARE METER kJ KILOJOULE kPa KILO PASCAL kV COEFFICIENT, VALVE FLOW (METRIC)
L LITERS
LAV LAVATORY
LAT LEAVING AIR TEMPERATURE
LG LENGTH
LH LATENT HEAT
LL LIQUID LINE
LPM LITERS PER METER
LPD LITERS PER DAY
LPH LITERS PER HOUR
LPS LITERS PER SECOND
LWT LEAVING WATER TEMPERATURE
M or m METERS
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MM or mm MILLIMETERS
MPH METERS PER HOUR
MPS METERS PER SECOND
MSB MOP SINK BASIN
MTD MOUNTED
MV MIXING VALVE
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO. NUMBER
NOM NOMINAL
NTS, N.T.S. NOT TO SCALE
OB OUTLET BOX
OC ON CENTER
OD OUTSIDE DIAMETER
OF OVERFLOW
OH OVERHEAD
OPNG OPENING
OPER OPERATING
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OS&Y OUTSIDE SCREW & YOLK
OXY OXYGEN
P PUMP
Pa PASCAL
PD PRESSURE DROP
PG PRESSURE GAUGE
PH PHASE
PLBG PLUMBING
PLC PUMP LEVEL CONTROL(S)
PNL PANEL
POC POINT OF CONNECTION
POD POINT OF DISCONNECT
PRESS PRESSURE
PS PRESSURE SWITCH
PV PLUG VALVE
PVC POLYVINYL CHLORIDE
P/TRV PRESSURE / TEMPERATURE RELIEF
VALVE
QTY QUANTITY
R RADON
(R) RELOCATED
RE: REFERENCE, REFER
RECIRC RECIRCULATE
REINF REINFORCING
REQD REQUIRED
REV REVISION, REVISE
RH ROOF HYDRANT
RLA RUNNING LOAD AMPERES
RM ROOM
RPM REVOLUTIONS PER MINUTE
SECT SECTION
SEER SEASONAL ENERGY EFFICIENCY RATIO
SH SHOWER
SHD SHOWER DRAIN
SIM SIMILAR
SK SINK
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL
ASSOCIATION
SM SQUARE METER
SOV SHUT-OFF VALVE
SP SUMP PUMP
SPEC SPECIFICATION
SQ SQUARE
SS SANITARY SEWER
STD STANDARD
STRUC STRUCTURAL
SW COLD WATER (SOFT)
SV SUPPLY VALVE
SYM SYMBOL
S=% SLOPE AT PERCENTAGE SHOWN
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
THRU THROUGH
TMV THERMOSTATIC MIXING VALVE
TOP, T.O.P. TOP OF PIPE
TP TRAP PRIMER OR TRAP PRIMING
TYP TYPICAL
TW TEPID WATER
TWR TEPID WATER RETURN
U/F UNDER FLOOR
U/G UNDERGROUND
U/S UNDER SLAB
UFC UNIFIED FACILITIES CRITERIA
UL UNDERWRITERS LABORATORIES, INC.
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTR UP THROUGH ROOF
V VENT
VAC VOLTAGE ALTERNATING CURRENT
VBF VENT BELOW FLOOR
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VLV VALVE
VOR VALVE ON RISER
VTR VENT THROUGH ROOF
W WATTS
W/ WITH
W/O WITHOUT
WAP WALL ACCESS PANEL
WC WATER CLOSET
W.C. WATER COLUMN
WCO WALL CLEANOUT
WH WALL HYDRANT
WHA WATER HAMMER ARRESTOR
WM WATER METER
WP WEATHER PROOF
WPD WATER PRESSURE DROP
WS WATER SOFTENER
WSFU WATER SUPPLY FIXTURE UNITS
WT WEIGHT
PLUMBING GENERAL NOTES
R RADON BELOW FLOOR/GRADE
BFP BACKFLOW PREVENTER
ABA ARCHITECTURAL BARRIERS ACT
ABS ACRYLONITRILE BUTADIENE STYRENE
ABV ABOVE
AC AIR COMPRESSOR
ADJ ADJUSTABLE
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SURFACE
AHU AIR HANDLING UNIT
AMP AMPERE(S)
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
AS AIR SEPARATOR
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND AIR
CONDITIONING ENGINEERS.
AUX AUXILIARY
AV AIR VENT
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VALVE
BHP BRAKE HORSEPOWER
BLDG BUILDING
BOP, B.O.P. BOTTOM OF PIPE
BOS BOTTOM OF STEEL
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BV BALL VALVE
BWV BACK WATER VALVE
CA COMPRESSED AIR
CAP. CAPACITY
CBV CALIBRATED BALANCE VALVE
CD CONDENSATE DRAIN
CDF CONDENSATE DRAIN FUNNEL
CDP CONDENSATE DRAIN PUMP
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CH CHILLER
CI CAST IRON
CIRC CIRCULATING
CLG CEILING
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COND CONDENSATE
CONN CONNECT, CONNECTION
CONT CONTINUE, CONTINUATION
COTG CLEANOUT TO GRADE
CP CIRCULATING PUMP
CR CONDENSATE RECEIVER
CU CONDENSING UNIT
CV CHECK VALVE
°C DEGREES CELSIUS
DCW DOMESTIC COLD WATER
DEG DEGREE(S)
DFU DRAINAGE FIXTURE UNIT
DWH DOMESTIC HOT WATER (SUPPLY)
DWHR DOMESTIC HOT WATER RETURN
DIA OR Ø DIAMETER
DIM DIMENSION
DISC DISCONNECT
DISCH DISCHARGE
DIST DISTANCE
DN DOWN
DS DOWNSPOUT
DWG(S) DRAWING(S)
DWH DOMESTIC WATER HEATER
E EXISTING
EA EACH
EER ENERGY EFFICIENCY RATIO
EEW EMERGENCY EYEWASH
EFF EFFICIENCY
ELEV, EL ELEVATION
ELEC ELECTRICAL
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
EQV EARTHQUAKE VALVE
ESE EMERGENCY SHOWER/EYEWASH
ET EXPANSION TANK
EXT EXTERNAL
EWC ELECTRIC WATER COOLER
PRESSURE REDUCING VALVE
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
NTS
/2
/2
:3
:0 A
M
OSB-P-001
742434
C R
A N
E
IN
D
IA
N
A
12810943
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
S Y
M B
O L S
N
O T
E S
A
N D
A B
B R
E V
IA
T
IO
N
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -P
-0
P
L U
M B
IN
G
S Y
M B
O L
S
N O
T E
S A
N D
A B
B R
E V
IA
T
IO
N
S
RDS/PJB
ALG
EJA
1629197
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
4"Ø SS
2"Ø DCW
WH-1
WH-1
HB-1
HB-1
ESE-1
ST-1
OFFICE
ELECTRICAL ROOM
INSTRUMENTATION
ROOM
LAUNCH CONTROL
CENTER
COMMUNICATIONS
ROOM
BREAK ROOM
LTV & CANISTER
MAINTENANCE AREA
LCC EQUIPMENT
ROOM
CONFERENCE ROOM
CORRIDOR
4"Ø SS
1/
2" Ø
C A
1 1/2"Ø DCW
AC-1
2" Ø
D C
W
WH-1
IWH
OSB-P-101
C1
BFP-1
FS-1
ESE-2
IWH
1 1
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/ 4"
Ø C
D
3/ 4"
Ø C
D
FCO
1/
2" Ø
C A
IWH
IB-1
3/4"Ø DCW
OFFICE
OFFICE
4"Ø R
4"Ø SS
WH-1
SK-1
4"Ø R
4"Ø R
4"Ø R
4"Ø R
HB-1
1 1/2"Ø CA
I.E. = 714.2'
7654321
A
B
C
D
E
A.8
D.2
1 1/4"Ø DHW
1 1/2"Ø DCW
1 1/2"Ø DCW
4" Ø
S S
2" DOMESTIC
WATER METER
2"Ø SS
FCO
AD-1
F
11 11
FD-2
12 12
1% S
LO
P
E
1% SLOPETYPICAL
20' - 0"
'-0
TY
P
IC
A L
1/
2" Ø
V
1"Ø CA
3/4"Ø CD
IWH
FD-2
FD-1
FD-1 IWH
IWH
3/4"Ø DCW
3/4"Ø CD
FCO
WC-1 WC-1
LAV-1LAV-1TOILET
TOILET
JANITOR
4"Ø SS
1 1/2"Ø V
3"Ø V
2"Ø V
WCO
E
D.2
3/4"Ø DCW
1 1/4"Ø DCW
MSB-1
EWC-1 3"Ø SS
3/4"Ø DCW
2"Ø V
3/4"Ø DCW
3/4"Ø CD
A. REFER TO OSB-P-001 FOR PLUMBING SYMBOLS, NOTES, AND
ABBREVIATIONS.
B. ALL UNDERGROUND RADON PIPING TO BE PERFORATED PVC. ALL
ABOVE GRADE RADON PIPING TO BE SOLID PVC PIPE.
C. F.G.E. = 718.9'
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
As indicated
/2
/2
:3
:0 A
M
OSB-P-101
742435
C R
A N
E
IN
D
IA
N
A
12810944
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
F L O
O R
P L A
N
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -P
-1
P
L U
M B
IN
G
F L
O O
R P
L A
N
RDS/PJB
ALG
EJA
1629197
1/8" = 1'-0"A1
PLUMBING FLOOR PLAN
1/4" = 1'-0"C1
ENLARGED PLUMBING PLAN
1 COMPRESSED AIR DROP TO AIR HOSE CONNECTION. REFER TO
DETAIL B2 / OSB-P-501 FOR MORE INFORMATION.
2 INDOOR WALL MOUNTED HVAC UNIT PROVIDED BY MECHANICAL
CONTRACTOR. UNIT PROVIDED WITH WALL MOUNTED
CONDENSATE PUMP. REFER TO MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
3 4"Ø RADON PIPING UP THROUGH ROOF. REFER TO
ARCHITECTURAL SHEET OSB-A-016 FOR ROOF PENETRATION
DETAILS.
4 TERMINATE CONDENSATE DRAIN 6" ABOVE MOP SINK BASIN DRAIN
LEVEL. CUT DRAIN PIPING AT 45 DEGREE ANGLE TO MINIMIZE
SPLASHING.
5 3"Ø VENT THROUGH ROOF. REFER TO ARCHITECTURAL SHEET
OSB-A-016 FOR ROOF PENETRATION DETAILS.
6 WATER PIPE SIZES ARE BASED ON A MINIMUM WORKING
PRESSURE OF 70 PSIG AT A FLOW RATE OF 57 GPM AFTER THE
PRESSURE REDUCING VALVE. REFER TO CIVIL PLANS FOR
CONTINUATION.
7 TOTAL SANITARY DRAINAGE FIXTURE UNITS (DFU'S) EQUALS 38.
REFER TO CIVIL PLANS FOR CONTINUATION.
8 PROVIDE HEAT TRACE TAPE FOR EXTERIOR PIPING FREEZE
PROTECTION. COORDINATE WITH ELECTRICAL CONTRACTOR FOR
HEAT TRACE POWER.
9 PROVIDE EXTERIOR COMPRESSED AIR QUICK CONNECT OUTLET.
10 PROVIDE 1/2" DCW CONNECTION FOR COFFEE POT (NIC).
11 INDOOR ABOVE CEILING HVAC UNIT PROVIDED BY MECHANICAL
CONTRACTOR. MECHANICAL CONTRACTOR TO PROVIDE
CONDENSATE PUMP. REFER TO MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
12 CONDENSATE PUMPED UP FROM MECHANICAL AC UNIT.
8'4' 16'0
SCALE: 1/8"=1'-0"
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
PLAN NORTH
GENERAL SHEET NOTES
SHEET KEYNOTES#
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
1 1/4" TEMPERED WATER
FINISHED FLOOR
1/2" STAY-OPEN
BALL VALVE
1" (STAY OPEN) BALL VALVE
SHOWER HEAD
PULL ROD
BOWL
PUSH FLAG HANDLE
MOUNT LIGHT AND ALARM ON
WALL AT 8'-0"± AFF. LIGHT AND
ALARM ON OUTDOOR UNIT TO BE
RATED FOR EXTERIOR USE.
1-1/4" HW
1-1/4" CW
INSTANTANEOUS
WATER HEATER
FINISHED WALL
WALL BOX
FLANGE
WALL CLAMP (IF
USED)
INLET CONNECTION
INSIDE BACK OF WALL
ALL QUICK DISCONNECT COUPLINGS
AND FITTINGS SHALL MATCH OWNER'S
EXISTING EQUIPMENT AND SHALL BE
VERIFIED
REGULATOR
5-150 PSI, MAX FLOW 140 CFM
1/2"
1/2" QUICK CONNECT
COUPLINGS
1"
BALL VALVE
(TYP.)
PRESSURE GAUGE
1/2"
1/2" QUICK CONNECT
COUPLINGS
REGULATOR
5-150 PSI, MAX FLOW 140 CFM
PRESSURE GAUGE
DIRT LEG
NON-SHRINK GROUT
FLOOR DRAIN OR
FLOOR SINK
FINISHED FLOOR
"P" TRAP
REFER PLANS
FOR SIZES
WASTE TRAP SEAL TO BE
PROVIDED WITH ALL FLOOR
DRAINS AND FLOOR SINKS.
HANGER ROD
LOCKING NUT
SUPPORT NUT
INSULATION
PIPE
HEAVY DUTY
CLEVIS HANGER
14 GAGE SHIELD 18" LONG TO
PROTECT INSULATION
TO STRUCTURE
DOMESTIC COLD
WATER (REFER TO
PLAN FOR SIZES)
DOMESTIC COLD
WATER (REFER TO
PLAN FOR SIZES)
BALL VALVE (TYP.)
UNION (TYP.)
PRESSURE GAUGE
(TYP.)
PRESSURE REDUCING
VALVE SET TO 70PSI
REDUCED PRESSURE
BACKFLOW PREVENTER
STRAINER M
WATER METER
DOMESTIC
HOT WATER
BALL VALVE
CHECK VALVE
WHADOMESTIC COLD
WATER (REFER TO
PLAN FOR SIZES)
MB-1
INSTANTANEOUS
WATER HEATER
TEST COCKS
STRAINER
FOR CONNECTION TO
MECHANICAL EQUIPMENT,
REFER TO PLANS FOR SIZING
DRAIN TO SPILL INDIRECTLY
OVER NEAREST FLOOR SINK
AIR GAP FITTING SIZE
PER BACKFLOW
PREVENTER SIZE
REDUCED PRESSURE ZONE
ASSEMBLY WITH STRAINER
BALL VALVE
TYPICAL
BV
SINGLE LAVATORY OR SINK
REFER TO PLAN FOR
FIXTURE CALLOUT.
DOMESTIC COLD
WATER (REFER TO
PLAN FOR SIZES) BV
TYPICAL CHASE BRANCH LINE
AND FIXTURES. REFER TO
PLANS FOR CW LINE SIZES
AND FIXTURE CALLOUTS.
DOMESTIC COLD
WATER (REFER TO
PLAN FOR SIZES)
WHA (TYP)
REFER TO PDI-WH 201
AND WATER HAMMER
ARRESTOR SCHEDULE
FOR SIZING.
WHA (TYP)
REFER TO PDI-WH 201
AND WATER HAMMER
ARRESTOR SCHEDULE
FOR SIZING.
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
As indicated
/2
/2
:3
:0 A
M
OSB-P-501
742436
C R
A N
E
IN
D
IA
N
A
12810945
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
D E
T A
IL
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -P
-5
P
L U
M B
IN
G
D E
T A
IL
S
RDS/PJB
ALG
EJA
1629197
NOT TO SCALEA1
EMERGENCY SHOWER UNIT DETAIL
NOT TO SCALEB1
FREEZE PROOF WALL HYDRANT DETAIL
NOT TO SCALEB2
WALL MOUNTED COMPRESSED AIR
DETAIL NOT TO SCALEB4
TYPICAL FLOOR DRAIN AND FLOOR SINK
DETAIL
NOT TO SCALED1
CLEVIS HANGER DETAIL WITH
INSULATION
1/4" = 1'-0"C4
INCOMING DOMESTIC WATER DETAIL
NOT TO SCALEA5
MOP BASIN DOMESTIC WATER DETAIL
NOT TO SCALEA3
REDUCED PRESSURE ZONE
BACKFLOW PREVENTER
NOT TO SCALEC2
WATER HAMMER ARRESTOR DETAIL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
OUTLET
DUCTING
AC-1
PRE-FILTER
OIL-WATER
SEPARATOR
DESICCANT
AIR DRYER
30 GALLON
TANK
AC-1
INTAKE DUCT
OIL-WATER
SEPARATOR
AIR
CONDITIONER
DESICCANT AIR
DRYER
CABINET
TRANSFORMER & 120 PANEL
480 PANEL
PRE-FILTER
FLOOR DRAIN
DISCONNECT
SECTION VIEW
PLAN VIEW
30 GALLON TANK
COMPRESSED AIR
CONNECTION POINT
ELECTRIC
HEATER
ELECTRIC
HEATER
AIR
CONDITIONER
8'
0" W
ID
TH
NOTE:
CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL AIR COMPRESSOR COMPONENTS, ACCESSORIES, ETC. IN ORDER TO PROVIDE A COMPLETE AND FUNCTIONAL AIR COMPRESSOR ENCLOSURE AND
COMPRESSED AIR SYSTEM.
12' - 0" LENGTH
NOTE:
CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL AIR COMPRESSOR COMPONENTS, ACCESSORIES, ETC. IN ORDER TO PROVIDE A COMPLETE AND FUNCTIONAL AIR COMPRESSOR ENCLOSURE AND
COMPRESSED AIR SYSTEM.
AC-2
OIL-WATER
SEPARATOR
PRE-FILTER
DESICCANT AIR
DRYER
CONTROLLER
ELECTRIC
HEATER
AIR
CONDITIONER
CABINET
AIR
CONDITIONER
PRE-FILTER
OIL-WATER
SEPARATOR
DESICCANT
AIR DRYER
30 GALLON TANK
ELECTRIC
HEATER
AC-2
INTAKE DUCT
PLAN VIEW
SECTION VIEW
20' - 0" LENGTH
OUTLET
DUCTING
90° EXHAUST
HOOD
8'
0" W
ID
TH
480 PANEL
TRANSFORMER
& 120 PANEL
DISCONNECT
480 PANEL
TRANSFORMER
& 120 PANEL
OUTLET DUCT
TO ROOF
COMPRESSED
AIR CONNECTION
POINT
COMPRESSED
AIR CONNECTION
POINT
30 GALLON
TANK
CONDENSATE TO DRAIN TO FLOOR
DRAIN IN EQUIPMENT. COORDINATE
CONDENSATE DISCHARGE
LOCATION WITH FLOOR DRAIN
SHOWN ON CIVIL PLANS.
1"∅ THREADED PIPE
PROVIDE PIPE STANCHION
SADDLE (MSS SP-58 TYPE 37)
CONTINUOUS INSULATION
THROUGH PIPE SUPPORT
INSULATION SADDLES "U" BOLT OR SIMILAR PIPE
CLAMP.
WALL
1/4"x6"x6" PLATE
PIPE SUPPORT
SCREWED TO WALL
INSULATED PIPE WITH
PROTECTION SHIELD AT
CLAMP LOCATIONS. MAINTAIN
SPECIFIED SLOPE.
NOTE: IF PIPES ARE LOCATED OVER CONCRETE, THE OFFSET CLAMPS MAY
BE DIRECTLY ATTACHED WITHOUT THE TREATED LUMBER SUPPORT.
PROVIDE REMOVABLE 16 GAUGE
ALUMINUM TREADPLATE FOR
PROTECTION FROM
MAINTENANCE TRAFFIC
OFFSET PIPE CLAMP ATTACH TO 4 x 4
TREATED LUMBER
SUPPORT
STAND
ROLLER
LOCKING NUT
HANGER ROD
PIPE
INSULATION (NOT
VAPOR BARRIER)
BOLT PIPE ROLLER TO
CHANNEL
14 GAUGE INSULATION
SHIELD. MIN. 18" LONG
PIPE SADDLE AT
LEAST 18" LONG
PIPE NO
INSULATION
VAPOR BARRIER
INSULATION
6" CHANNEL
C TO C
MAX SPACING 42"
L L
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
As indicated
/2
/2
:3
:0 A
M
OSB-P-502
742437
C R
A N
E
IN
D
IA
N
A
12810946
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
D E
T A
IL
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -P
-5
P
L U
M B
IN
G
D E
T A
IL
S
RDS/PJB
ALG
EJA
1629197
NOT TO SCALEA1
TYPE 1 AIR COMPRESSOR ENCLOSURE
DETAIL
NOT TO SCALEA3
TYPE 2 AIR COMPRESSOR ENCLOSURE
DETAIL
NOT TO SCALED3
WALL MOUNTED PIPE SUPPORT DETAIL
NOT TO SCALED1
GRADE MOUNTED PIPE SUPPORT DETAIL
NOT TO SCALED2
TRAPEZE HANGER DETAIL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
/2
/2
:3
:1 A
M
OSB-P-601
742438
C R
A N
E
IN
D
IA
N
A
12810947
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
S C
H E
D U
L E
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -P
-6
P
L U
M B
IN
G
S C
H E
D U
L E
S
RDS/PJB
ALG
EJA
1629197
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE
MINIMUM CONNECTION SIZE
DESCRIPTION
SS V CW HW TW
BFP-1 BUILDING BACKFLOW PREVENTER 2" REDUCED PRESSURE ZONE BACKFLOW PREVENTER WITH STRAINER, AIR GAP FITTING, AND QUARTER TURN BALL VALVES.
ESE-1 EXTERIOR EMERGENCY SHOWER / EYEWASH 3" 2"
1 1/4" NON-FREEZE, EXTERIOR SAFETY SHOWER WITH EYE WASH, GALVANIZED STEEL PIPING, PLASTIC SHOWERHEAD AND BOWL, AUDIBLE ALARM AND STROBE, AND NEMA 4X WEATHERPROOF
CONTROLS ENCLOSURE. PROVIDE LOCKABLE SHUTOFF VALVE LOCKED IN THE NORMALLY OPEN POSITION.
ESE-2 EMERGENCY SHOWER / EYEWASH
1 1/4" PROVIDE SHOWER WITH EYE-FACE WASH, GALVANIZED STEEL PIPING, PLASTIC SHOWERHEAD AND BOWL, AUDIBLE ALARM AND STROBE, AND NEMA 4X WEATHERPROOF CONTROLS
ENCLOSURE. PROVIDE LOCKABLE SHUTOFF VALVE LOCKED IN THE NORMALLY OPEN POSITION.
EWC-1 ELECTRIC WATER COOLER 1 1/4" 1 1/4" 1/2" BI-LEVEL ELECTRIC WATER COOLER WITH BOTTLE FILLER
FCO FLOOR CLEANOUT SIZE SAME AS CONNECTED PIPING. SEE FLOOR PLANS AND ISOMETRICS FOR SIZING; PROVIDE WITH TRAFFIC RATED COVER.
FD-1 FLOOR DRAIN 2" 1 1/2" CAST IRON ADJUSTABLE COLLAR AND 7"ø NICKEL BRONZE STRAINER.
FD-2 FLOOR DRAIN 3" 2" CAST IRON ADJUSTABLE COLLAR AND 7"ø NICKEL BRONZE STRAINER.
FS-1 FLOOR SINK 4" 2" 12" x 12" x 8" DEEP FLOOR SINK WITH HEAVY DUTY GRATE AND SEDIMENT BUCKET.
HB-1 HOSE BIBB 3/4" WALL MOUNTED WITH VACUUM BREAKER
IB-1 ICE MAKER BOX 1/2" WALL MOUNTED ICE MAKER BOX WITH QUARTER TURN HANDLES
LAV-1 LAVATORY 1 1/4" 1 1/4" 1/2" 1/2" WALL HUNG WITH 0.5 GPM MANUAL FAUCET. MOUNT UNIT WITH TOP OF BOWL 34 INCHES AFF.
MSB-1 MOP SINK BASIN 3" 2" 1/2" 1/2" 24"X24"X12" TERRAZZO MOP SINK WITH HOSE BRACKET, HOSE, STAINLESS STEEL CAPS, AND STAINLESS STEEL WALL GUARD.
SK-1 KITCHEN SINK 1 1/2" 1 1/4" 1/2" 1/2" SINGLE 19"X19"X6" BOWL, STAINLESS STEEL, TOP MOUNT; 1.5 GPM MANUAL FAUCET WITH SINGLE LEVER.
ST-1 SAND TRAP 4" 24"X24" HEAVY DUTY GRATE. 60 GALLON CAPACITY.
WC-1 WATER CLOSET 4" 2" 1" WALL HUNG WITH MANUAL 1.1 GPF FLUSH VALVE. MOUNT UNIT WITH TOP OF BOWL 18 INCHES AFF.
WCO WALL CLEANOUT SIZE SAME AS CONNECTED PIPING. SEE FLOOR PLANS AND ISOMETRICS FOR SIZING; PROVIDE WITH CHROME WALL PLATE
WH-1 WALL HYDRANT 3/4"
CHROME-PLATED QUARTER TURN NON-FREEZE AUTOMATIC DRAINING HYDRANT, 3/4" MALE HOSE THREAD OUTLET CONNECTION, INTEGRAL VACUUM BREAKER, INTEGRAL SERVICE SHUTOFF
VALVE, DUAL CHECK VALVE, "T" HANDLE KEY.
INSTANTANEOUS WATER HEATER SCHEDULE
MARK SERVES LOCATION FLOW CAPACITY
TEMPERATURE
RISE @ FLOW
OUTLET
TEMPERATURE
ELECTRICAL
NOTESMCA VOLTAGE PHASE
IWH-01 KITCHEN SINK 111 - BREAK ROOM 1.5 GPM 20.0 kW 61 °F 110 °F 24 A 460 V 3 3
IWH-02 MOP SINK BASIN 114 - JANITOR 2.2 GPM 24.0 kW 68 °F 120 °F 29 A 460 V 3 3
IWH-03 LAVATORY 115 - TOILET 0.5 GPM 4.1 kW 56 °F 105 °F 20 A 208 V 1 3
IWH-04 LAVATORY 116 - TOILET 0.5 GPM 4.1 kW 56 °F 105 °F 20 A 208 V 1 3
IWH-05 EMERGENCY EYEWASH / SHOWERS 101 - LTV & CANISTER MAINTENANCE AREA 20.0 GPM 96.0 kW 33 °F 85 °F 116 A 460 V 3 1,2,3,4
IWH-06 EMERGENCY EYEWASH / SHOWERS 101 - LTV & CANISTER MAINTENANCE AREA 20.0 GPM 96.0 kW 33 °F 85 °F 116 A 460 V 3 1,2,3,4
WATER HAMMER ARRESTOR SCHEDULE
MARK FIXTURE UNITS PIPE SIZE HEIGHT DIAMETER NOTES
WHA-A 1-11 3/4" 2.62" 3.25" 1
WHA-B 12-32 1" 2.97" 3.25" 1
WHA-C 33-60 1" 3.59" 3.25" 1
WHA-D 61-113 1" 5.14" 3.25" 1
WHA-E 114-154 1" 5.52" 3.25" 1
WHA-F 155-330 1" 6.67" 3.25" 1
AIR COMPRESSOR SCHEDULE
MARK SERVES TYPE
FREE AIR
DELIVERY
MAXIMUM
PRESSURE HP
ELECTRICAL DATA
WEIGHT NOTESFLA VOLTAGE PHASE
AC-1 101 - LTV & CANISTER MAINTENANCE AREA ROTARY SCREW 58 CFM 145 psi 15 hp 27 A 460 V 3 1,200 lb 1,2,4,5
AC-2 LRSE BUILDING ROTARY SCREW 108 CFM 200 psi 50 hp 65 A 460 V 3 2,700 lb 1,2,3,4,5
NOTES:
1. LOCATED OUTSIDE OF BUILDING. PROVIDE WITH VENTED AND HEATED ENCLOSURE. ENCLOSURE TO HAVE MANUFACTURER'S RECOMMENDED CLEARANCE ON ALL SIDES FOR MAINTENANCE. ENCLOSURE TO
HAVE ALL REQUIRED COMPONENTS TO PROVIDE A COMPLETE FACTORY BUILT COMPRESSED AIR SYSTEM.
2. PROVIDE WITH DESICCANT AIR DRYER.
3. UNIT TO BE LOCATED NEAR LRSE. PROVIDE WITH QUICK CONNECT TO ENCLOSURE FOR USERS TO CONNECT / DISCONNECT AS NEEDED. REFER TO CIVIL PLANS FOR LOCATION OF AC-2.
4. REFER TO OSB-M-706 FOR AIR COMPRESSOR SEQUENCE OF OPERATIONS.
5. PROVIDE UNITS WITH PRE-FILTERS AND POST FILTERS. ISO CLASS TO BE 2:2:1. (PARTICLES, DEW POINT, OIL).
NOTES:
1. PROVIDE WITH ACCESS PANEL.
NOTES:
1. PROVIDE WITH NON-FUSED DISCONNECT.
2. PROVIDE FULLY MODULATING OPERATION.
3. PROVIDE WITH BUILT-IN SCALD PROTECTION
4. PROVIDE WITH NEMA 4 RATED ENCLOSURE.
AIR DRYER (AD) SCHEDULE
MARK SERVES TYPE PURGE AIR
-40°F INLET
CAPACITY
ELECTRICAL DATA
WEIGHT NOTESFLA VOLTAGE PHASE
AD-1 AC-1 DESICCANT 13 CFM 90 CFM 5 A 120 V 1 500 lb 1,2
AD-2 AC-2 DESICCANT 29 CFM 200 CFM 5 A 120 V 1 800 lb 1,2
NOTES:
1. PROVIDE UNITS WITH MANUAL SHUTOFF TO SHUT OFF AIR COMPRESSOR ASSEMBLY SO THAT AIR DRYER IS NOT PURGING AIR DURING NON-USE TIMES.
2. PROVIDE WITH OIL WATER SEPARATOR. AIR DRYER AND RECEIVER TANK CONDENSATE SHALL DISCHARGE THROUGH OIL WATER SEPARATOR BEFORE DISCHARGING TO
SANITARY SEWER FLOOR DRAIN.
FAN SCHEDULE
MARK TYPE CFM
ESP (IN.
WC)
FAN
RPM
ELECTRICAL
NOTESFLA V PH HZ
F-1 INLINE 150 1.00 2715 2.1 120 1 60 1
NOTES:
1. PROVIDE RADON FAN WITH EC MOTOR
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
IWH
ESE-1
HB-1
IWH
05ESE-2
BFP-1
HB-1
WH-1
WH-1
WH-1
IWH
IB-1
IWH
IWH
IWH
WH-1
WC-1
WC-1
LAV-1
LAV-1
1 1/4"Ø DCW
3/4"Ø DCW
3/4"Ø DCW
3/4"Ø DCW
3/4"Ø DCW
2"Ø DCW
1 1/4"Ø DCW2"Ø DCW
3/4"Ø DCW
2"Ø DCW
1 1/2"Ø DCW
3/4"Ø DCW
1 1/2"Ø DCW
1 1/4"Ø DCW
3/4"Ø DCW
1/2"Ø DCW
3/4"Ø DCW
1 1/4"Ø DCW
1/2"Ø DHW
1/2"Ø DCW
1/2"Ø DCW1/2"Ø DCW
1 1/4"Ø DHW
HB-1
3/4"Ø DCW
2"Ø DCW
1 1/2"Ø DCW
SK-1
EWC-1
1/2"Ø DCW
MSB-1
2" DOMESTIC WATER
METER WITH DIRECT READ
REGISTER
PROVIDE LOCKABLE
BALL VALVE
PROVIDE LOCKABLE
BALL VALVE
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
/2
/2
:3
:1 A
M
OSB-P-901
742439
C R
A N
E
IN
D
IA
N
A
12810948
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
I S
O M
E T
R
IC
S
N S
A C
R A
N E
P -4
U
N D
E R
W A
T E
R L
A U
N C
H T
E S
T F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
O S
B -P
-9
P
L U
M B
IN
G
I S
O M
E T
R
IC
S
RDS/PJB
ALG
EJA
1629197
A1
DOMESTIC WATER PIPING ISOMETRIC
NOT TO SCALE
NTS
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R F
P P
H A
S E
S
U B
M
IS
S
IO
N
/0
/2
4"Ø SSESE-1
ST-1
FCO
4"Ø SS
4"Ø SS
4"Ø SS
FS-1
ESE-2
4"Ø SS
FD-1
WC-1
WC-1 FD-2
FCO
LAV-1
LAV-1
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
4"Ø SS
WALL HUNG HVAC UNIT
PROVIDED BY MECHANICAL
CONTRACTOR. REFER TO
MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
WALL HUNG HVAC UNIT
PROVIDED BY MECHANICAL
CONTRACTOR. REFER TO
MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
ABOVE CEILING HVAC UNIT
PROVIDED BY MECHANICAL
CONTRACTOR. REFER TO
MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
2"Ø V
3"Ø V
3"Ø V
2"Ø V
3"Ø V
2"Ø V
2"Ø V
2" Ø
V
1 1/4"Ø V
1 1/2"Ø SS
4"Ø SS
4"Ø SS
3"Ø SS
FD-1
3"Ø V
2"Ø V
1 1/2"Ø V
4"Ø SS
4"Ø SS
4"Ø SS
SK-1
4"Ø SS
EWC-1
1 1/4"Ø SS
MSB-1
FCO
4"Ø SS
SANITARY CONNECTION TO
FLOOR DRAIN IN AC-1
ENCLOSURE.
3/4"Ø CD
FD-2 3"Ø SS
1 1/2"Ø SS
3"Ø SS
3"Ø SS
3"Ø SS
3/4"Ø CD
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
O P
E R
A T
IO
N
S S
U P
P O
R T
B U
IL
D
IN
G
M
ID
L A
N T
C I
C O
R E
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
2/24/2020
/2
/2
:3
:1 A
M
OSB-P-902
742440
C R
A N
E
IN
D
IA
N
A
12810949
N40085-19-R-9186
WE WE AB
P L U
M B
IN
G
I…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .