1629197dwgVol3_Sheet427-494_F.pdf

PDF 11 MB Posted

Attached to
Design-Bid-Build, P409 Underwater Launch Test Facility (ULTF), Crane, Indiana
Solicitation number
N4008519R9186
Issued by

About this file

This solicitation is for the design and construction of a new Underwater Launch Test Facility to support submerged launch testing and evaluation of full-scale launch technologies. Key details include:

  • The project involves construction of an Underwater Launch Pit, Operational Support Building, Warehouse Building, Water Treatment Facility, and Mechanical and Electrical Building to support testing. Supporting site work includes pavement, utilities and environmental mitigation.

  • Construction will be phased with initial site work and storage pad by month seven and beneficial occupancy by month eighteen after contract award. The solicitation requires responses by Jun 2020 from the Department of the Navy Naval Facilities Engineering Command.

  • The Operational Support Building will include a high bay area for vehicle maintenance and tool storage and a low bay for control centers, offices and other support spaces.

  • Utilities include water distribution and treatment for the launch pit, fire protection, sewer, electrical distribution and site lighting.

  • The scope requires design, construction services, equipment outfitting to support underwater launch testing and evaluation.

View the file

Other files

File Type Posted
Amendment 0015.pdf PDF
Streams and Wetlands Permit.pdf PDF
Amendment 0014.pdf PDF
NOSSA Final Site Approval.pdf PDF
NPDES Permit.pdf PDF
C2 OSB-A-017_C2 Weep Hole Edit.pdf PDF
G-002 Index Title Edit.pdf PDF
Spec Section 41 22 13.16 Page 2 Gantry Spec Typo.pdf PDF
G-003 Index Title Edit.pdf PDF
Amendment 0013.pdf PDF
UTF-C-002_CATEX Note 15 Removed.pdf PDF
Crane Test Facility Permit.pdf PDF
31 00 00 Blasting in LP only.pdf PDF
Amendment 0012.pdf PDF
PPI 109 UTF Drawing.pdf PDF
PPI 131 attachment Spec 22 00 00 Spec Edits.pdf PDF
Amendment 0011.pdf PDF
Amendment 0010.pdf PDF
Amendment 0009.pdf PDF
PPI 33 attachment_20200604rev1.pdf PDF
Amendment 0008.pdf PDF
UTF-C-103 Phasing Plan.pdf PDF
PPI 35 attachment_01 57 19 Edits.pdf PDF
PPI 33 attachment_20200604.pdf PDF
PPI 26 attachment_BLDG3680-1629197-UTF-C-201_207-2A-2B.pdf PDF
1629197dwgVol1_Sheet092-107_C.pdf PDF
1629197dwgVol2_Sheet302-321_T.pdf PDF
1629197dwgVol2_Sheet338-350_E.pdf PDF
ULTF_Geotechnical Design Report Rev 2_Volume 2_Part2.pdf PDF
1629197dwgVol1_Sheet063-080_C.pdf PDF
1629197dwgVol1_Sheet042-046_B.pdf PDF
ULTF_Geotechnical Design Report Rev 2_Volume 2_Part1.pdf PDF
1629197dwgVol1_Sheet015-026_V.pdf PDF
1629197spcVol1_Divs 00-06.pdf PDF
1629197dwgVol1_Sheet136-149_C.pdf PDF
1629197dwgVol2_Sheet150-167_G.pdf PDF
ULTF_Geotechnical Design Report Rev 2_Volume 1.pdf PDF
1629197dwgVol2_Sheet331-337_E.pdf PDF
1629197dwgVol1_Sheet051_062_C site exist and demo.pdf PDF
1629197dwgVol1_Sheet108-121_C.pdf PDF
1629197dwgVol2_Sheet168-188_S.pdf PDF
1629197dwgVol1_Sheet122-135_C.pdf PDF
1629197dwgVol1_Sheet081-091_C.pdf PDF
1629197dwgVol4_Sheet495-574_G.pdf PDF
1629197dwgVol1_Sheet001-014_G.pdf PDF
1629197spcVol3_Div 25.pdf PDF
1629197dwgVol1_Sheet047-050_B.pdf PDF
1629197spcVol2_Divs 07-23.pdf PDF
1629197dwgVol2_Sheet237-255_E.pdf PDF
Amendment 0007.pdf PDF
Show 40 more

Latest 50 of 115 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE ALARM

GENERAL NOTES ACU AUTONOMOUS CONTROL UNIT

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AVG AVERAGE

CA CLEAN AGENT

CO CONTRACTING OFFICER

COR CONTRACTING OFFICER REPRESENTATIVE

COTR CONTRACTING OFFICERS TECHNICAL REPRESENTATIVE

ELEV ELEVATION

EOL END OF LINE RESISTOR

FPC FIRE PUMP CONTROLLER

IDC INITIATING DEVICE CIRCUIT

MIN MINIMUM

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NONCOMBUSTIBLE

NIC NOT IN CONTRACT

NP NOT PERMITTED

NTS NOT TO SCALE

QFPE QUALIFIED FIRE PROTECTION ENGINEER

SQFT SQUARE FEET

WP WEATHER PROOF

GENERAL NOTES ABBREVIATIONS

(ALL SYMBOLS AND ABBREVIATIONS SHOWN ARE NOT

NECESSARILY USED ON THE DRAWINGS)

A. THE FIRE ALARM SYSTEM SHALL BE DESIGNED, INSTALLED, AND COMMISSIONED IN

ACCORDANCE WITH THE FOLLOWING:

• INTERNATIONAL BUILDING CODE (IBC), (2015 EDITION)

• NFPA 72 (2019 EDITION)

• UFC 3-600-01 (CHANGE 3, MAY 2019)

B. THE CONTRACTOR SHALL RETAIN THE SERVICES OF A QUALIFIED FIRE PROTECTION ENGINEER

(QFPE) AS DEFINED BY UFC 3-600-01. THE QFPE SHALL BE RESPONSIBLE FOR THE DESIGN,

INSPECTION, AND TESTING OF THE FIRE PROTECTION SYSTEMS THROUGHOUT THE BUILDING.

C. THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE

UTILIZED AS GUIDANCE FOR THE PLANNING OF THE SYSTEM BY THE CONTRACTOR. PROVIDE

COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER OF RECORD AND

THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP

DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING

INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION

AND COMPLY WITH LOCAL CODES, AMENDMENTS AND BASE STANDARDS.

D. FOR COMPLETE SYSTEM CONTROL, REFER TO THE MATRIX OF OPERATIONS WITHIN THIS

PACKAGE.

E. PROVIDE A COMPLETE NEW FIRE ALARM SYSTEM WITH VOICE COMMUNICATION CAPABILITY

THROUGHOUT EACH BUILDING. A SINGLE FIRE ALARM CONTROL PANEL SHALL BE UTILIZED TO

SERVE EACH BUILDING. SYSTEM MUST BE COMPATIBLE WITH THE BASE STANDARD SIGNAL

COMMUNICATIONS DTX - 16 ZONE 141.0 MHZ SYSTEM.

F. FINAL FIRE ALARM SYSTEM TEST SHALL BE WITNESSED BY THE QFPE. FILE A "RECORD OF

COMPLETION" PREPARED IN ACCORDANCE WITH NFPA 72, RECORDS OF TESTING AND

INSPECTION AS WELL AS ALL ITEMS REQUIRED BY SPECIFICATION 28 31 63.00 20, AND THE FIRE

ALARM TEST REPORT WITH THE AHJ.

G. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES SHALL NOT EXCEED 2 FLASHES PER

SECOND, NOR BE LESS THAN 1 FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A

MAXIMUM PULSE DURATION SHALL BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40%, IN

ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES SHALL BE SPACED IN

ACCORDANCE WITH NFPA 72. ALL STROBES SHALL BE SYNCHRONIZED.

H. AUDIBLE FIRE ALARM SOUND LEVELS SHALL BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST

60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE

OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE

FROM THE AUDILE APPLIANCE. PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT

THE FACILITY TO MEET THE NFPA 72 REQUIREMENTS. AUDIBILITY THROUGHOUT THE BUILDING

SHALL BE MET WITH ALL DOORS, SHUTTERS, PARTITIONS, ETC. CLOSED.

I. SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES SHALL BE INSTALLED UNDER

SPECIFICATION SECTION 21 13 13.00 20. CONNECT DEVICES TO THE FIRE ALARM SIGNALING LINE

CIRCUITS.

J. OBTAIN APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.

K. DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER THAN 3 FEET FROM AN AIR SUPPLY OR

RETURN DIFFUSER.

L. MOUNT ALL WALL-MOUNTED VISUAL AND VISUAL/AUDIBLE NOTIFICATION APPLIANCES WITH THE

ENTIRE STROBE LENS BETWEEN 80" TO 96" ABOVE THE FINISHED FLOOR.

M. FIRE ALARM CIRCUITS ARE TO BE CLASS B. T-TAPS AND WIRE NUTS ARE NOT PERMITTED.

N. ALL DUCT SMOKE DETECTORS SHALL BE PROVIDED WITH A REMOTE TEST/INDICATOR SWITCH

ASSEMBLY. THE REMOTE ASSEMBLY SHALL BE LOCATED 5 FEET AFF.

O. PROVIDE SURGE SUPPRESSORS ON ALL EXTERIOR CIRCUITS AND ALL 120VAC POWER

CIRCUITS. SURGE SUPPRESSOR SHALL BE INSTALLED ON THE CIRCUIT WITHIN 3 FEET OF THE

POINT WHERE THE CIRCUIT ENTERS OR LEAVES THE BUILDING.

P. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINE DESIGNS.

SYMBOLS - PANEL

SYMBOL DESCRIPTION

MONITOR MODULE

SYMBOLS - MISCELLANEOUS

SYMBOL DESCRIPTION

MANUAL PULL STATION

SYMBOLS - INITIATING

S,R

ID

P,I,ASD

SMOKE DETECTOR

P = PHOTOELECTRIC

I = IONIZATION

ASD = AIR SAMPLING DETECTOR

DUCT DETECTOR

ID = FAN UNIT DESIGNATION

S = SUPPLY

R = RETURN

MM

CONTROL MODULECM

TAMPER SWITCH

C WATER FLOW SWITCH

TS

WF

SYMBOL DESCRIPTION

FACP FIRE ALARM CONTROL PANEL

ANN ANNUNCIATOR PANEL

RADIO ALARM TRANSMITTER (SIGNAL COMMUNICATIONS DTX-16

TRANSCEIVER)

NOTIFICATION APPLIANCE CONTROL PANEL

RAT

NAC

F

SURGE SUPPRESSORSS

SYMBOL DESCRIPTION

FIRE ALARM SPEAKER / STROBE

(CEILING-MOUNTED, UNLESS OTHERWISE NOTED)

CD = CANDELA RATING

SYMBOLS - NOTIFICATION

#CD

SPEAKER (WALL-MOUNTED, UNLESS OTHERWISE NOTED)

WP = WEATHER PROOF

WP

FIRE ALARM STROBE

(CEILING-MOUNTED, UNLESS OTHERWISE NOTED)

CD = CANDELA RATING

#CD

FIRE ALARM STROBE

(WALL-MOUNTED, UNLESS OTHERWISE NOTED)

CD = CANDELA RATING

FIRE ALARM SPEAKER/STROBE

(WALL-MOUNTED, UNLESS OTHERWISE NOTED)

CD = CANDELA RATING, WP = WEATHER PROOF

SPEAKER (CEILING-MOUNTED, UNLESS OTHERWISE NOTED)

WP = WEATHER PROOFWP

#CD

#CD

FIXED TEMPERATURE HEAT DETECTOR (165 DEGREE F)

END OF LINE RESISTOR

C

PRESSURE SWITCH

LOW AIR PRESSURE SWITCH

C

PS

C

LAP

WP

FADC FIRE ALARM DOCUMENT CABINET

HORN (WALL-MOUNTED, UNLESS OTHERWISE NOTED)

WP = WEATHER PROOF

WP

F

#CD

HORN/STROBE (WALL-MOUNTED, UNLESS OTHERWISE NOTED)

CD = CANDELA RATING

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

NTS

/2

/2

:3

:3 A

M

OSB-FA001

742427

C R

A N

E

IN

D

IA

N

A

12810936

N40085-19-R-9186

JCM WTE MC

F

IR

E A

L A

R M

G E

N E

R A

L N

O T

E S

S

Y M

B O

L S

A

N D

A B

B R

E V

IA

T

IO

N

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

A

F

IR

E A

L A

R M

G E

N E

R A

L N

O T

E S

S

Y M

B O

L S

A

N D

A B

B R

E V

IA

T

IO

N

S

RDS/PJB

DSN

EJA

1629197

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

F F

F A

C P

C

WF

C

TS

15 30

15 15

F

P P

P

P P

F

MM MM

CM CM

CM

F

F A

D C

R A

T

C

TS

P

A

B

C

D

E

A.8

D.2

JAN. CL

LCC EQUIPMENT

ROOM

CONFERENCE ROOM

INSTRUMENTATION

ROOM

OFFICE

OFFICE

OFFICE

CLOSET

BREAK ROOM

LAUNCH CONTROL

CENTER

LTV & CANISTER

MAINTENANCE AREA

CORRIDOR

1 1

AHU-01 (SUPPLY) AHU-02 (SUPPLY)

AHU-03 (SUPPLY)

2 2

W P 3

A

B

C

D

E

A.8

D.2

STORAGE

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

1/8" = 1'-0"

/2

/2

:3

:3 A

M

OSB-FA101

742428

C R

A N

E

IN

D

IA

N

A

12810937

N40085-19-R-9186

JCM WTE MC

F

IR

E A

L A

R M

F L O

O R

P L A

N S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

A

F

IR

E A

L A

R M

F L O

O R

P L A

N S

RDS/PJB

DSN

EJA

1629197

1/8" = 1'-0"A1

FIRE ALARM FIRST FLOOR PLAN

1/8" = 1'-0"A4

FIRE ALARM MEZZANINE PLAN

A. REFER TO SHEET OSB-FA001 FOR FIRE ALARM GENERAL NOTES,

SYMBOLS, AND ABBREVIATIONS.

B. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR

COORDINATION WITH LIGHTS, MECHANICAL DIFFUSERS, AND

CEILING GRID.

C. REFER TO UTF-ES101 THRU UTF-ES305 FOR DUCT BANK LAYOUT

AND SECTIONS.

1 INSTALL THREE (3) SMOKE DETECTORS IN THE LOCATION SHOWN:

UNDERFLOOR, CEILING, AND ABOVE CEILING.

2 PROVIDE ADDRESSABLE CONTROL MODULE FOR INTERFACE WITH

DUCT SMOKE DETECTOR.

3 WEATHERPROOF HORN SHALL ACTIVATE UPON WATER FLOW.

4 PROVIDE FIRE ALARM DOCUMENT CABINET IN ACCORDANCE WITH

NFPA 72. INSERT FIRE ALARM SYSTEM DOCUMENTATION WITHIN

CABINET.

5 PROVIDE RADIO ALARM ANTENNAE ON SIDE OF OSB. CONTRACTOR

TO CONFIRM FINAL LOCATION AFTER TESTING FOR OPTIMAL

SIGNAL.

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL SHEET NOTES

SHEET KEYNOTES#

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

CONDUIT FROM

PREVIOUS DEVICES

CONDUIT TO

REMAINING DEVICES

FIRE ALARM NOTIFICATION

APPLIANCE LOCATION ZONE

(AUDIBLE ONLY APPLIANCES

SHALL BE MOUNTED NOT LESS

THAN 90" AFF AND NOT LESSTHAN

6" BELOW THE FINISHED CEILING)

FINISHED FLOOR

FINISHED CEILING

(WHERE PROVIDED)

A

FF

A

FF

A

FF

FIRE

SIGNALING LINE AND

NOTIFICATION APPLIANCE

CIRCUIT CONDUIT

(SINGLE CONDUIT, WHEN

PERMITTED BY MANUFACTURER)

MAXIMUM HORIZONTAL

DISTANCE TO EXIT IS 5

FEET

MOUNTED PULL

STATION AND

BACKBOX

JUNCTION BOX

DETECTOR BASE

SMOKE

EXPOSED CEILING

DETECTOR

J-BOX ON

3/4" EMT CONDUIT

SMOKE

MEMBER

STRUCTURAL

MASTER

FACP

(6) 15 (2)

(3) 30 (2)

OSB NOTIFICATION - STROBES

OSB NOTIFICATION - SPEAKERS

OSB SIGNALING LINE CIRCUIT

BATTERY

120 VAC

F P

(12) (4)

MM

C

TS

MM

C

WF

(1) (1)

(1)

SS

FIRE ALARM NETWORK TO

NEXT FACP

SS

FIRE ALARM NETWORK TO

NEXT FACP

RAT

DROP CEILING TILE

DETECTOR BASE

SMOKE

4"x4"x2-1/8" J-BOX

J-BOX ON FLOOR SLAB

SMOKE DETECTOR

1/2" FLEX WITH FIRE DETECTION

CIRCUITS. FLEXIBLE CONNECTION

MAY NOT EXCEED 6 FEET AND MAY

NOT BE EXPOSED.

"T" BAR TYPE HANGER

3/4" EMT CONDUIT

MASTER

FACP

FACP

FACP

RAT

SS

SS

SS

SS

SSSS

OSB

WHS

FIRE PUMP

BUILDING

FACP

FACP

SS

SS

SS

SS

MEB

WTB

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

NTS

/2

/2

:3

:4 A

M

OSB-FA501

742429

C R

A N

E

IN

D

IA

N

A

12810938

N40085-19-R-9186

JCM WTE MC

F

IR

E A

L A

R M

D E

T A

IL

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

A

F

IR

E A

L A

R M

D E

T A

IL

S

RDS/PJB

DSN

EJA

1629197

NTSB1

FIRE ALARM MOUNTING DETAIL

NTSD1

EXPOSED CEILING DETECTOR DETAIL

NTSA3

OSB FIRE ALARM RISER DIAGRAM

NOT TO SCALEA1

SUSPENDED CEILING DETECTOR DETAIL

NTSB3

FIRE ALARM NETWORK DIAGRAM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

CONTROL UNIT

ANNUNCIATION NOTIFICATION

LIFE SAFETY

CONTROL

B U

IL

D

IN

G

F A

C P

A L A

R M

L E

D A

N D

A U

D

IB

L E

S

IG

N A

L

B U

IL

D

IN

G

F A

C P

S U

P E

R V

IS

O

R Y

L E

D A

N D

A U

D

IB

L E

S

IG

N A

L

B U

IL

D

IN

G

F A

C P

T R

O U

B L E

L E

D A

N D

A U

D

IB

L E

S

IG

N A

L

T R

A N

S M

IT

A

L A

R M

S

IG

N A

L T

O B

A S

E C

E N

T R

A L S

T A

T

IO

N M

O N

IT

O

R

IN

G S

T A

T

IO

N

T R

A N

S M

IT

S

U P

E R

V

IS

O R

Y S

IG

N

A L T

O B

A S

E C

E N

T R

A L M

O N

IT

O

R

IN

G S

T A

T

IO

N

T R

A N

S M

IT

T

R O

U B

L E

S

IG

N A

L T

O B

A S

E C

E N

T R

A L M

O N

IT

O

R

IN

G S

T A

T

IO

N

A C

T

IV

A T E

F

IR

E A

L A

R M

A U

D

IB

L E

A N

D V

IS

U

A L N

O T

IF

IC

A

T

IO

N A

P P

L

IA

N C

E S

W

IT

H

IN

B U

IL

D

IN

G

SYSTEM OUTPUTS

MANUAL FIRE ALARM PULL STATION

SYSTEM INPUT

AREA SMOKE DETECTOR2

A B C D E F G H I J K L M N O P Q R S T U

A B C D E F G H I J K L M N O P Q R S T U

INDICATES ACTION WILL CAUSE A SPECIFIC RESULT

EMPTY SQUARE INDICATES ACTION WILL NOT CAUSE A SPECIFIC RESULT

V

V W

W

D E

A C

T

IV

A T E

P U

B L

IC

A D

D R

E S

S S

Y S

T E

M

DUCT SMOKE DETECTOR

WATER FLOW SWITCH

VALVE TAMPER SWITCH

PANEL AC POWER FAIL

PANEL LOW BATTERY

OPEN CIRCUIT

GROUND FAULT

SHORT CIRCUIT

12 PANEL TROUBLE

S H

U T D

O W

N A

S S

O C

IA

T E

D H

V A

C U

N

IT

18 ---

A C

T

IV

A T E

F

IR

E A

L A

R M

A U

D

IB

L E

A N

D V

IS

U

A L N

O T

IF

IC

A

T

IO

N A

P P

L

IA

N C

E S

O N

B U

IL

D

IN

G

E X

T E

R

IO

R

RAT

ANTENNA

BATTERY

120 VAC

SPARE

SPARE

SPARE

SPARE

MEB ALARM SS

MEB TROUBLE SS

MEB SUPERVISORY SS

FPE ALARM SS

OSB ALARM

OSB TROUBLE

OSB SUPERVISORYSS SS SS SS SS SS SS SS SS

WHS TROUBLESS

WHS SUPERVISORYSS

WTB ALARMSS

WTB TROUBLESS

WHS ALARMSS

WTB SUPERVISORYSS

SSSS SS

FPE TROUBLE SS

FPE SUPERVISORY SS

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

NTS

/2

/2

:3

:4 A

M

OSB-FA502

742430

C R

A N

E

IN

D

IA

N

A

12810939

N40085-19-R-9186

JCM WTE MC

F

IR

E A

L A

R M

M A

T R

IX

O

F O

P E

R A

T

IO

N S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

A

F

IR

E A

L A

R M

M A

T R

IX

O

F O

P E

R A

T

IO

N S

RDS/PJB

DSN

EJA

1629197

NTSA1

FIRE ALARM MATRIX OF OPERATIONS

NTSA3

RADIO ALARM TRANSMITTER (RAT) RISER

DIAGRAM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

SPRINKLER DESIGN CRITERIA

HAZARD

CLASSIFICATION

DENSITY

REQUIREMENTS

DURATION

OF

SUPPLY

MAXIMUM

SPRINKLER

PROTECTION AREA

SPRINKLER

TEMPERATURE

WATERFLOW TEST DATA

TEST DATE: MARCH 27, 2019

STATIC PRESSURE: 104 PSI

RESIDUAL PRESSURE: 81 PSI

1453 GPMDISCHARGE FLOW:

HOSE

ALLOWANCE

60 MIN.

ORDINARY

0.20 GPM/SQFT OVER

MOST REMOTE 2,500 SQFT

130 SQFT ORDINARY 250 GPM

GAUGE HYDRANT # AND LOCATION: GAUGE HYDRANT #1124

FLOW HYDRANT #1201FLOW HYDRANT # AND LOCATION:

K-FACTOR

8.0

60 MIN.

LIGHT

0.10 GPM/SQFT OVER

MOST REMOTE 1,500 SQFT

225 SQFT ORDINARY 250 GPM5.6

GENERAL NOTES AND SYMBOLS

PIPING SYMBOLS

FIRE SPRINKLER SYMBOLS

DIRECTION OF SLOPE DOWN

PRESSURE CONTROL VALVE

TEST PORT

RELIEF VALVE

GATE VALVE

CHECK VALVE

ECCENTRIC REDUCER

TEE OUTLET DOWN

TEE OUTLET UP

CONCENTRIC REDUCER

UNION

FIRE SPRINKLER NOTES

ELBOW DOWN

VALVE IN DROP

VALVE IN CENTER DROP

VALVE IN RISE

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

DIRECTION OF FLOW

ELBOW UP

A. PROVIDE COMPLETE WET PIPE FIRE SPRINKLER SYSTEMS FOR

THE ENTIRE BUILDING AND A DRY-PIPE SYSTEM FOR THE

CANOPY DESIGNED AND INSTALLED IN ACCORDANCE WITH UFC

3-600-01 WITH CHANGE 3 (MAY 2019), IBC (2015 EDITION), AND

NFPA 13 (2019 EDITION).

B. THE CONTRACTOR SHALL RETAIN THE SERVICES OF A

QUALIFIED FIRE PROTECTION ENGINEER (QFPE) AS DEFINED BY

UFC 3-600-01. THE QFPE SHALL BE RESPONSIBLE FOR THE

DESIGN, INSPECTION, AND TESTING OF THE FIRE PROTECTION

SYSTEMS THROUGHOUT THE BUILDING.

C. VERIFY ALL LOCATIONS AND MEASUREMENTS AS CONDITIONS

MAY VARY THROUGHOUT CONSTRUCTION. ALL CHANGES FROM

THE ORIGINAL DESIGN MUST BE APPROVED BY THE QFPE.

D. SPRINKLER CONTRACTOR SHALL INSTALL TAMPER AND FLOW

SWITCHES. CONNECTIONS TO THE FIRE ALARM SYSTEM'S

SIGNALING LINE CIRCUIT SHALL BE MADE UNDER

SPECIFICATION DIVISION 28.

E. SPRINKLER CONTRACTOR SHALL UTILIZE FLOW DATA

PROVIDED TO BASE HYDRAULIC CALCULATIONS AND SIZE

PIPING. IF THE TEST RESULTS ARE OVER SIX MONTHS OLD,

SPRINKLER CONTRACTOR TO PERFORM A NEW HYDRANT FLOW

TEST.

F. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND

APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.

G. HYDRAULICALLY CALCULATE THE WET PIPE SPRINKLER

SYSTEMS PER NFPA 13 DENSITY AND SPACING LISTED IN THE

SPRINKLER DESIGN CRITERIA TABLE BELOW. FIELD VERIFY

SYSTEM DESIGN AND LAYOUT PRIOR TO FABRICATION OR

INSTALLATION.

H. PROVIDE PIPE HANGERS ON ALL FIRE SPRINKLER SYSTEM

PIPING AND EQUIPMENT PER NFPA 13.

I. SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE

AND ROOM USE. SEE ARCHITECTURAL, ELECTRICAL,

MECHANICAL, AND TELECOMMUNICATIONS PLANS FOR THE

LOCATION OF ALL CEILING-MOUNTED DEVICES. FIELD VERIFY

AND COORDINATE THE LOCATIONS OF ALL SYSTEM

COMPONENTS INCLUDING PIPING, ALARMS, DRAINS, TEST

POINTS, ETC. WITH ARCHITECTURAL, STRUCTURAL,

MECHANICAL, AND ELECTRICAL EQUIPMENT WITHIN THE

BUILDING.

J. PROVIDE AUXILIARY DRAINAGE WITH A DRAIN VALVE AND PLUG

FOR ALL TRAPPED SECTION OF PIPE, AS REQUIRED BY NFPA 13.

K. THESE DOCUMENTS DEPICT PERFORMANCE LEVEL

ENGINEERING DESIGN CRITERIA TO BE UTILIZED AS GUIDANCE

FOR THE PLANNING OF THE FIRE SPRINKLER SYSTEM BY THE

CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW

AND APPROVAL FROM THE ENGINEER OF RECORD AND AHJ

PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS

AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY

TO PROVIDE A COMPLETE INSTALLATION.

L. PIPE MAIN DRAIN TO OUTSIDE OF BUILDING. PROVIDE SPLASH

BLOCK AS NECESSARY.

M. SPRINKLER SYSTEM DESIGN SHALL BE BASED ON THE RESULTS

OF THE WATER FLOW TEST AND OPERATION OF THE SITE FIRE

PUMP. FIRE PUMP SHALL BE RATED FOR 1,500 GPM @ 50 PSI.

N. BUILDING IS SEISMIC DESIGN CATEGORY C. REFER TO

STRUCTURAL DRAWINGS FOR DESIGN CRITERIA. SEISMIC

BRACING AND RESTRAINT OF BRANCH LINES SHALL BE

DESIGNED AND INSTALLED FOR ALL SPRINKLER PIPING IN

ACCORDANCE WITH NFPA 13 AND NFPA 13 ANNEX'S. BRANCH

LINES ARE REQUIRED TO BE RESTRAINED AGAINST EXCESSIVE

MOVEMENT, BOTH VERTICALLY AND LATERALLY (HORIZONTAL)

PER NFPA 13 EARTHQUAKE BRACING.

O. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINE DESIGNS.

PRESSURE GAUGE WITH

GAUGE COCK

STRAINER WITH

BLOWDOWN VALVE

SYSTEM RISER

ABBREVIATIONS

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AVG AVERAGE

BFP DOUBLE CHECK BACKFLOW PREVENTER

CFM CUBIC FEET PER MINUTE

CO CONTRACTING OFFICER

COTR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE

ELEV ELEVATION

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FHV FIRE HOSE VALVE

FP FIRE PUMP

FPC FIRE PUMP CONTROLLER

FVC FIRE VALVE CABINET

GALS GALLONS

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GV GATE VALVE

JP JOCKEY PUMP

MIN MINIMUM

NC NONCOMBUSTIBLE

NIC NOT IN CONTRACT

NP NOT PERMITTED

NTS NOT TO SCALE

OS&Y OUTSIDE SCREW & YOKE

PSIG POUNDS PER SQUARE INCH GAUGE

SOV SOLENOID VALVE

SQFT SQUARE FEET

UH UNIT HEATER

VLV VALVE

FLOW SWITCH

LH

OH

EH

LIGHT HAZARD OCCUPANCY

ORDINARY HAZARD OCCUPANCY

EXTRA HAZARD OCCUPANCY

UPRIGHT SPRINKLER

TC INSPECTOR'S TEST / DRAIN CONNECTION

COMBINED WALL MOUNTED FIRE

PUMP AND BACKFLOW PREVENTER

TEST CONNECTION WITH SIX 2-1/2"

VALVES

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

NTS

/2

/2

:3

:4 A

M

OSB-FX001

742431

C R

A N

E

IN

D

IA

N

A

12810940

N40085-19-R-9186

JCM WTE MC

F

IR

E S

U P

P R

E S

S

IO

N G

E N

E R

A L N

O T

E S

S

Y M

B O

L S

A

N D

A B

B R

E V

IA

T

IO

N

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

X

F

IR

E S

U P

P R

E S

S

IO

N G

E N

E R

A L

N O

T E

S

S Y

M B

O L S

A

N D

A B

B R

E V

IA

T

IO

N

S

RDS/PJB

DSN

EJA

1629197

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

A

B

C

D

E

A.8

D.2

ELECTRICAL ROOM

COMMUNICATIONS

ROOM

JAN. CL

UNISEX TLT

LCC EQUIPMENT

ROOM

CONFERENCE ROOM

INSTRUMENTATION

ROOM

OFFICE

OFFICE

OFFICE

CLOSET

BREAK ROOM

LAUNCH CONTROL

CENTER

UNISEX TLT

LTV & CANISTER

MAINTENANCE AREA

CORRIDOR

1 2

6"ø

6"ø

6"ø

6"ø

6"ø

6"ø

6"ø

6"ø

OH

OH

OH OH

OH

OH

LH LH

LH

LH

LH

LH

LH

LH

LH

A

B

C

D

E

A.8

D.2

OH

STORAGE

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

1/8" = 1'-0"

/2

/2

:3

:4 A

M

OSB-FX101

742432

C R

A N

E

IN

D

IA

N

A

12810941

N40085-19-R-9186

JCM WTE MC

F

IR

E S

U P

P R

E S

S

IO

N F

L O

O R

P L A

N S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

X

F

IR

E S

U P

P R

E S

S

IO

N F

L O

O R

P L A

N S

RDS/PJB

DSN

EJA

1629197

1/8" = 1'-0"A1

FIRE SUPPRESSION FIRST FLOOR PLAN

PLAN NORTH

8'4' 16'0

SCALE: 1/8"=1'-0"

A. REFER TO SHEET OSB-FX001 FOR FIRE SUPPRESSION GENERAL

NOTES, SYMBOLS, AND ABBREVIATIONS.

B. WET-PIPE SPRINKLER COVERAGE IS PROVIDED UNLESS NOTED

OTHERWISE.

C. NO PIPING TO BE INSTALLED OVER TOP OF ELECTRICAL OR

TELECOMMUNICATION EQUIPMENT.

D. REFER TO UTF-CS109 THRU UTF-CS110 FOR EXISTING HYDRANTS

1124 AND 1201 FLOW TEST INFORMATION.

1 FIRE DEPARTMENT CONNECTION

2 INSPECTOR'S TEST / DRAIN CONNECTION

3 PROVIDE A SEPARATE SPRINKLER ZONE FOR THE LAUNCH

CONTROL CENTER, INSTRUMENTATION ROOM, AND LCC

EQUIPMENT ROOM (BOUNDARIES INDICATED WITH DASHED LINE).

4 PROVIDE SAFETY STRIPING AROUND SPRINKLER RISER. REFER TO

ARCHITECTURAL SIGNAGE PLANS FOR DETAILS.

5 PROVIDE A CONTROL VALVE WITH TAMPER SWITCH, CHECK VALVE,

AND WATER FLOW SWITCH ON SEPARATE SPRINKLER FEED TO

LAUNCH CONTROL CENTER, INSTRUMENTATION ROOM, AND LCC

EQUIPMENT ROOM.

1/8" = 1'-0"A4

FIRE SUPPRESSION MEZZANINE PLAN

GENERAL SHEET NOTES

SHEET KEYNOTES#

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

RETAINER

ALL THREAD

PIPE RING

ROD

WITH LOCKNUT

BEAM CLAMP

STRAP

MEMBER

STRUCTURAL

KEY NOTES

SPARE SPRINKLER CABINET

GATE VALVE

CHECK VALVE

WATER FLOW INDICATOR

FIRE DEPARTMENT CONNECTION

INSPECTOR'S TEST/DRAIN CONNECTION

3 4

TO DRAIN

TO SYSTEM

TC

BACKFILL

U N

D E

R C

O M

P A

C T

E D

S O

IL

UNDERGROUND

TERMINATES IN

FLANGED SPIGOT

PIECE

EXTERIOR

WALL

GRADE

DUCTILE IRON CEMENT LINED

UNDERGROUND DUCTILE

IRON CEMENT LINED PIPE.

CONCRETE THRUST

BLOCK TYP. AT ALL

INCOMING WATER

SERVICES. 10 SF

MINIMUM OF BEARING

SURFACE.

UNDERGROUND MAIN

SAND BACKFILL (TYP.)

M

IN

IM

U

M C

O V

E R

ROD PIPE-TYPICAL JOINT RESTRAINT AT ALL

INCOMING WATER SERVICES PER NFPA 24. COAT

WITH ASPHALT.

PROVIDE 2" ANNULAR SPACE

AROUND PIPE

THROUGH CONCRETE

SLAB AROUND DUCTILE

IRON PIPE. SPACE

SHALL BE FILLED WITH

A FLEXIBLE MASTIC

MATERIAL

3/4"Ø STEEL TIE RODS

BITUMASTIC COATED

CONCRETE

FLOOR

NOTE:

WORK 5'-0" OUTSIDE BUILDNG

BY SITE UTILITY

CONTRACTOR.

FLEXIBLE COUPLING

ARM OVER SHALL MEET

NFPA 13 CRITERIA

SPRINKLER MAIN

OR BRANCH LINE

SUSPENDED CEILING

RECESSED SPRINKLER

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

As indicated

/2

/2

:3

:4 A

M

OSB-FX501

742433

C R

A N

E

IN

D

IA

N

A

12810942

N40085-19-R-9186

JCM WTE MC

F

IR

E S

U P

P R

E S

S

IO

N D

E T

A

IL

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -F

X

F

IR

E S

U P

P R

E S

S

IO

N D

E T

A

IL

S

RDS/PJB

DSN

EJA

1629197

NTSB1

BEAM CLAMP HANGER DETAIL

NTSB4

FIRE SUPPRESSION RISER SCHEMATIC

DIAGRAM

A3

RISER 3D ISOMETRIC VIEW

NTSC2

FIRE WATER SERVICE DETAIL

NTSNTSA1

SPRINKLER ARM OVER DETAIL (TYPICAL)

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

XX

PLUMBING ABBREVIATIONS PLUMBING LEGEND AND SYMBOLS

SPECIAL INSPECTIONS

SYMBOL ABBREVIATION DESCRIPTION

PLUGGED PIPE/OUTLET

CONCENTRIC REDUCER

ECCENTRIC REDUCER

CAPPED PIPE/OUTLET

UNION

P/TRV

U

PRESSURE/TEMPERATURE RELIEF VALVE

HB/WH

SOV

FLEXIBLE PIPE CONNECTOR

HOSE BIBB / WALL HYDRANT

ANCHOR

WATER HAMMER ARRESTER

FLUID FLOW DIRECTION

WHA

GAS COCK

DOMESTIC HOT WATER RETURN LINEDHWR

THERMOMETER

NOTE: NOT ALL ABBREVIATIONS AND

SYMBOLS SHOWN HEREIN ARE UTILIZED.

CHECK VALVECV

TOP CONNECTION

BOTTOM CONNECTION

CO OR WCO CLEANOUT OR WALL CLEANOUT

FCO FLOOR CLEANOUT

COTG CLEANOUT TO GRADE

SHUT-OFF VALVE OR ISOLATION VALVE

BALANCING VALVE

PIPE UP OR DOWN BASED ON SYSTEM

PIPE ELBOW UP OR DOWN BASED ON SYSTEM FLOW

SANITARY SEWER/WASTE

EXPANSION JOINT

SQUARE FLOOR DRAIN OR SHOWER DRAIN

FLOOR SINK

KITCHEN EQUIPMENT TAG

BALL VALVE

DCW DOMESTIC COLD WATER SUPPLY

EQUIPMENT CALL OUT

DHW DOMESTIC HOT WATER SUPPLY

SANITARY SEWER/WASTE BELOW FLOOR/GRADE

NATURAL GASGASG

SS

WHEN THE CONTRACTOR IS REQUIRED BY THE GOVERNMENT TO PROVIDE SPECIAL INSPECTIONS AS PART OF THE WORK, THE CONTRACTOR SHALL RETAIN THIRD-PARTY QUALITY ASSURANCE AGENCIES TO CONDUCT THE SPECIAL INSPECTIONS REQUIRED BY THE IBC. THESE INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE ICC IBC 2018 AND THE DESIGN DOCUMENTS. THE INSPECTING AGENCY SHALL PROVIDE REPORTS OF THE SPECIAL INSPECTIONS DIRECTLY TO THE GOVERNMENT. REFER TO SPECIAL

INSPECTIONS SPECIFICATION SECTIONS FOR DEFINITIONS AND ADDITIONAL REQUIREMENTS.

GREASE WASTE

1. PROVIDE LABOR AND MATERIALS TO DELIVER COMPLETE AND PROPERLY FUNCTIONING PLUMBING SYSTEMS.

2. PROVIDE PLUMBING WORK IN ACCORDANCE WITH CONTRACT SPECIFICATIONS, IPC 2018, UFC REQUIREMENTS, AND APPLICABLE

LOCAL CODES.

3. COORDINATE PLUMBING WORK WITH SITE CONDITIONS AND WORK OF OTHER TRADES. VERIFY SLOPES AND INVERT ELEVATIONS

PRIOR TO COMMENCEMENT OF WORK.

4. FURNISH MATERIALS, CUTTING, PATCHING, ADAPTING AND OTHER INCIDENTAL WORK, TOGETHER WITH SUCH TEMPORARY

CONNECTIONS AS MAY BE REQUIRED.

5. PROVIDE PIPE PENETRATIONS THROUGH FLOOR SLAB AND WALLS WITH PIPE SLEEVES.

6. PROVIDE ACCESS PANELS FOR VALVES, WATER HAMMER ARRESTERS AND OTHER PLUMBING SPECIALTIES LOCATED INSIDE CHASES, BEHIND WALLS OR ABOVE INACCESSIBLE CEILING. COORDINATE EXACT LOCATIONS AND FINISHES OF ACCESS PANELS WITH

ARCHITECTURAL DRAWINGS.

7. PROVIDE SECONDARY STRUCTURAL STEEL MEMBERS FOR PIPING AND EQUIPMENT SUPPORTS. PROVIDE BOLTING AND WELDING OF SUPPORTS PER CONTRACT STRUCTURAL SPECIFICATIONS. SUBMIT SHOP DRAWINGS FOR GOVERNMENT APPROVAL.

8. VENT ROOF PENETRATIONS SHALL BE A MINIMUM OF 15 FT. HORIZONTALLY AWAY FROM THE ROOF EDGE AND AIR INTAKES.

9. PROVIDE FIRE STOPPING FOR PIPING CROSSING FIRE-RATED BARRIERS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED

BARRIER LOCATIONS.

10. MOUNT ALL OVERHEAD UTILITIES AND OTHER FIXTURES WEIGHING 31 POUNDS OR MORE (EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS THAT COLLECTIVELY EXCEED THAT WEIGHT) TO MINIMIZE THE LIKELIHOOD THAT THEY WILL FALL AND INJURE BUILDING OCCUPANTS. DESIGN ALL EQUIPMENT MOUNTINGS TO RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION. THIS STANDARD DOES NOT PRECLUDE THE NEED TO DESIGN EQUIPMENT MOUNTINGS FOR FORCES REQUIRED BY OTHER CRITERIA SUCH AS SEISMIC

STANDARDS.

11. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINE DESIGNS.

VENT

SS

GW

GW GREASE WASTE BELOW FLOOR/GRADE

KEYED NOTEXX

ROUND FLOOR DRAIN OR SHOWER DRAIN

CONDENSATE DRAINCD

R RADON

V

FC FAN COIL

FCO FLOOR CLEANOUT

FCW FILTERED COLD WATER

FD FLOOR DRAIN

FFE, F.F.E. FINISH FLOOR ELEVATION

FIN FLR ELEV

FGE, F.G.E. FINISH GRADE ELEVATION

FIN GRADE ELEV

FIN FINISH

FLA FULL LOAD AMPS

FLR FLOOR

FP FIRE PROTECTION

FS FLOOR SINK

FWD FOOD WASTE DISPOSER

G NATURAL GAS

GA GAUGE, GAGE

GALV GALVANIZED

GPR GAS PRESSURE REGULATOR

GW GREASE WASTE

H HEIGHT

HB HOSE BIBB

HD HEAD

HORIZ HORIZONTAL

HP HORSEPOWER

HR HOSE REEL

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

HZ HERTZ

ID INSIDE DIAMETER

IE, I.E. INVERT ELEVATION

IT INFORMATION TECHNOLOGY

J JOULE

K KELVIN

kCAL/HR KILOCALORIES PER HOUR kG KILOGRAM kG/SQ CM KILOGRAM PER SQUARE CENTIMETER kG/SM KILOGRAM PER SQUARE METER kJ KILOJOULE kPa KILO PASCAL kV COEFFICIENT, VALVE FLOW (METRIC)

L LITERS

LAV LAVATORY

LAT LEAVING AIR TEMPERATURE

LG LENGTH

LH LATENT HEAT

LL LIQUID LINE

LPM LITERS PER METER

LPD LITERS PER DAY

LPH LITERS PER HOUR

LPS LITERS PER SECOND

LWT LEAVING WATER TEMPERATURE

M or m METERS

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MM or mm MILLIMETERS

MPH METERS PER HOUR

MPS METERS PER SECOND

MSB MOP SINK BASIN

MTD MOUNTED

MV MIXING VALVE

N/A NOT APPLICABLE

NC NORMALLY CLOSED

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NO. NUMBER

NOM NOMINAL

NTS, N.T.S. NOT TO SCALE

OB OUTLET BOX

OC ON CENTER

OD OUTSIDE DIAMETER

OF OVERFLOW

OH OVERHEAD

OPNG OPENING

OPER OPERATING

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINISTRATION

OS&Y OUTSIDE SCREW & YOLK

OXY OXYGEN

P PUMP

Pa PASCAL

PD PRESSURE DROP

PG PRESSURE GAUGE

PH PHASE

PLBG PLUMBING

PLC PUMP LEVEL CONTROL(S)

PNL PANEL

POC POINT OF CONNECTION

POD POINT OF DISCONNECT

PRESS PRESSURE

PS PRESSURE SWITCH

PV PLUG VALVE

PVC POLYVINYL CHLORIDE

P/TRV PRESSURE / TEMPERATURE RELIEF

VALVE

QTY QUANTITY

R RADON

(R) RELOCATED

RE: REFERENCE, REFER

RECIRC RECIRCULATE

REINF REINFORCING

REQD REQUIRED

REV REVISION, REVISE

RH ROOF HYDRANT

RLA RUNNING LOAD AMPERES

RM ROOM

RPM REVOLUTIONS PER MINUTE

SECT SECTION

SEER SEASONAL ENERGY EFFICIENCY RATIO

SH SHOWER

SHD SHOWER DRAIN

SIM SIMILAR

SK SINK

SMACNA SHEET METAL AND AIR CONDITIONING

CONTRACTORS NATIONAL

ASSOCIATION

SM SQUARE METER

SOV SHUT-OFF VALVE

SP SUMP PUMP

SPEC SPECIFICATION

SQ SQUARE

SS SANITARY SEWER

STD STANDARD

STRUC STRUCTURAL

SW COLD WATER (SOFT)

SV SUPPLY VALVE

SYM SYMBOL

S=% SLOPE AT PERCENTAGE SHOWN

TD TRENCH DRAIN

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

THRU THROUGH

TMV THERMOSTATIC MIXING VALVE

TOP, T.O.P. TOP OF PIPE

TP TRAP PRIMER OR TRAP PRIMING

TYP TYPICAL

TW TEPID WATER

TWR TEPID WATER RETURN

U/F UNDER FLOOR

U/G UNDERGROUND

U/S UNDER SLAB

UFC UNIFIED FACILITIES CRITERIA

UL UNDERWRITERS LABORATORIES, INC.

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UR URINAL

UTR UP THROUGH ROOF

V VENT

VAC VOLTAGE ALTERNATING CURRENT

VBF VENT BELOW FLOOR

VEL VELOCITY

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VLV VALVE

VOR VALVE ON RISER

VTR VENT THROUGH ROOF

W WATTS

W/ WITH

W/O WITHOUT

WAP WALL ACCESS PANEL

WC WATER CLOSET

W.C. WATER COLUMN

WCO WALL CLEANOUT

WH WALL HYDRANT

WHA WATER HAMMER ARRESTOR

WM WATER METER

WP WEATHER PROOF

WPD WATER PRESSURE DROP

WS WATER SOFTENER

WSFU WATER SUPPLY FIXTURE UNITS

WT WEIGHT

PLUMBING GENERAL NOTES

R RADON BELOW FLOOR/GRADE

BFP BACKFLOW PREVENTER

ABA ARCHITECTURAL BARRIERS ACT

ABS ACRYLONITRILE BUTADIENE STYRENE

ABV ABOVE

AC AIR COMPRESSOR

ADJ ADJUSTABLE

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SURFACE

AHU AIR HANDLING UNIT

AMP AMPERE(S)

AP ACCESS PANEL

APPROX APPROXIMATE

ARCH ARCHITECT, ARCHITECTURAL

AS AIR SEPARATOR

ASHRAE AMERICAN SOCIETY OF HEATING,

REFRIGERATION, AND AIR

CONDITIONING ENGINEERS.

AUX AUXILIARY

AV AIR VENT

BFF BELOW FINISHED FLOOR

BFP BACKFLOW PREVENTER

BFV BUTTERFLY VALVE

BHP BRAKE HORSEPOWER

BLDG BUILDING

BOP, B.O.P. BOTTOM OF PIPE

BOS BOTTOM OF STEEL

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

BV BALL VALVE

BWV BACK WATER VALVE

CA COMPRESSED AIR

CAP. CAPACITY

CBV CALIBRATED BALANCE VALVE

CD CONDENSATE DRAIN

CDF CONDENSATE DRAIN FUNNEL

CDP CONDENSATE DRAIN PUMP

CF CUBIC FEET

CFH CUBIC FEET PER HOUR

CH CHILLER

CI CAST IRON

CIRC CIRCULATING

CLG CEILING

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COND CONDENSATE

CONN CONNECT, CONNECTION

CONT CONTINUE, CONTINUATION

COTG CLEANOUT TO GRADE

CP CIRCULATING PUMP

CR CONDENSATE RECEIVER

CU CONDENSING UNIT

CV CHECK VALVE

°C DEGREES CELSIUS

DCW DOMESTIC COLD WATER

DEG DEGREE(S)

DFU DRAINAGE FIXTURE UNIT

DWH DOMESTIC HOT WATER (SUPPLY)

DWHR DOMESTIC HOT WATER RETURN

DIA OR Ø DIAMETER

DIM DIMENSION

DISC DISCONNECT

DISCH DISCHARGE

DIST DISTANCE

DN DOWN

DS DOWNSPOUT

DWG(S) DRAWING(S)

DWH DOMESTIC WATER HEATER

E EXISTING

EA EACH

EER ENERGY EFFICIENCY RATIO

EEW EMERGENCY EYEWASH

EFF EFFICIENCY

ELEV, EL ELEVATION

ELEC ELECTRICAL

ENCL ENCLOSURE

EQ EQUAL

EQUIP EQUIPMENT

EQV EARTHQUAKE VALVE

ESE EMERGENCY SHOWER/EYEWASH

ET EXPANSION TANK

EXT EXTERNAL

EWC ELECTRIC WATER COOLER

PRESSURE REDUCING VALVE

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

NTS

/2

/2

:3

:0 A

M

OSB-P-001

742434

C R

A N

E

IN

D

IA

N

A

12810943

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

S Y

M B

O L S

N

O T

E S

A

N D

A B

B R

E V

IA

T

IO

N

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -P

-0

P

L U

M B

IN

G

S Y

M B

O L

S

N O

T E

S A

N D

A B

B R

E V

IA

T

IO

N

S

RDS/PJB

ALG

EJA

1629197

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

4"Ø SS

2"Ø DCW

WH-1

WH-1

HB-1

HB-1

ESE-1

ST-1

OFFICE

ELECTRICAL ROOM

INSTRUMENTATION

ROOM

LAUNCH CONTROL

CENTER

COMMUNICATIONS

ROOM

BREAK ROOM

LTV & CANISTER

MAINTENANCE AREA

LCC EQUIPMENT

ROOM

CONFERENCE ROOM

CORRIDOR

4"Ø SS

1/

2" Ø

C A

1 1/2"Ø DCW

AC-1

2" Ø

D C

W

WH-1

IWH

OSB-P-101

C1

BFP-1

FS-1

ESE-2

IWH

1 1

3/4"Ø CD

3/4"Ø CD

3/4"Ø CD

3/4"Ø CD

3/ 4"

Ø C

D

3/ 4"

Ø C

D

FCO

1/

2" Ø

C A

IWH

IB-1

3/4"Ø DCW

OFFICE

OFFICE

4"Ø R

4"Ø SS

WH-1

SK-1

4"Ø R

4"Ø R

4"Ø R

4"Ø R

HB-1

1 1/2"Ø CA

I.E. = 714.2'

7654321

A

B

C

D

E

A.8

D.2

1 1/4"Ø DHW

1 1/2"Ø DCW

1 1/2"Ø DCW

4" Ø

S S

2" DOMESTIC

WATER METER

2"Ø SS

FCO

AD-1

F

11 11

FD-2

12 12

1% S

LO

P

E

1% SLOPETYPICAL

20' - 0"

'-0

TY

P

IC

A L

1/

2" Ø

V

1"Ø CA

3/4"Ø CD

IWH

FD-2

FD-1

FD-1 IWH

IWH

3/4"Ø DCW

3/4"Ø CD

FCO

WC-1 WC-1

LAV-1LAV-1TOILET

TOILET

JANITOR

4"Ø SS

1 1/2"Ø V

3"Ø V

2"Ø V

WCO

E

D.2

3/4"Ø DCW

1 1/4"Ø DCW

MSB-1

EWC-1 3"Ø SS

3/4"Ø DCW

2"Ø V

3/4"Ø DCW

3/4"Ø CD

A. REFER TO OSB-P-001 FOR PLUMBING SYMBOLS, NOTES, AND

ABBREVIATIONS.

B. ALL UNDERGROUND RADON PIPING TO BE PERFORATED PVC. ALL

ABOVE GRADE RADON PIPING TO BE SOLID PVC PIPE.

C. F.G.E. = 718.9'

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

As indicated

/2

/2

:3

:0 A

M

OSB-P-101

742435

C R

A N

E

IN

D

IA

N

A

12810944

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

F L O

O R

P L A

N

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -P

-1

P

L U

M B

IN

G

F L

O O

R P

L A

N

RDS/PJB

ALG

EJA

1629197

1/8" = 1'-0"A1

PLUMBING FLOOR PLAN

1/4" = 1'-0"C1

ENLARGED PLUMBING PLAN

1 COMPRESSED AIR DROP TO AIR HOSE CONNECTION. REFER TO

DETAIL B2 / OSB-P-501 FOR MORE INFORMATION.

2 INDOOR WALL MOUNTED HVAC UNIT PROVIDED BY MECHANICAL

CONTRACTOR. UNIT PROVIDED WITH WALL MOUNTED

CONDENSATE PUMP. REFER TO MECHANICAL PLANS FOR

ADDITIONAL INFORMATION.

3 4"Ø RADON PIPING UP THROUGH ROOF. REFER TO

ARCHITECTURAL SHEET OSB-A-016 FOR ROOF PENETRATION

DETAILS.

4 TERMINATE CONDENSATE DRAIN 6" ABOVE MOP SINK BASIN DRAIN

LEVEL. CUT DRAIN PIPING AT 45 DEGREE ANGLE TO MINIMIZE

SPLASHING.

5 3"Ø VENT THROUGH ROOF. REFER TO ARCHITECTURAL SHEET

OSB-A-016 FOR ROOF PENETRATION DETAILS.

6 WATER PIPE SIZES ARE BASED ON A MINIMUM WORKING

PRESSURE OF 70 PSIG AT A FLOW RATE OF 57 GPM AFTER THE

PRESSURE REDUCING VALVE. REFER TO CIVIL PLANS FOR

CONTINUATION.

7 TOTAL SANITARY DRAINAGE FIXTURE UNITS (DFU'S) EQUALS 38.

REFER TO CIVIL PLANS FOR CONTINUATION.

8 PROVIDE HEAT TRACE TAPE FOR EXTERIOR PIPING FREEZE

PROTECTION. COORDINATE WITH ELECTRICAL CONTRACTOR FOR

HEAT TRACE POWER.

9 PROVIDE EXTERIOR COMPRESSED AIR QUICK CONNECT OUTLET.

10 PROVIDE 1/2" DCW CONNECTION FOR COFFEE POT (NIC).

11 INDOOR ABOVE CEILING HVAC UNIT PROVIDED BY MECHANICAL

CONTRACTOR. MECHANICAL CONTRACTOR TO PROVIDE

CONDENSATE PUMP. REFER TO MECHANICAL PLANS FOR

ADDITIONAL INFORMATION.

12 CONDENSATE PUMPED UP FROM MECHANICAL AC UNIT.

8'4' 16'0

SCALE: 1/8"=1'-0"

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

PLAN NORTH

GENERAL SHEET NOTES

SHEET KEYNOTES#

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

1 1/4" TEMPERED WATER

FINISHED FLOOR

1/2" STAY-OPEN

BALL VALVE

1" (STAY OPEN) BALL VALVE

SHOWER HEAD

PULL ROD

BOWL

PUSH FLAG HANDLE

MOUNT LIGHT AND ALARM ON

WALL AT 8'-0"± AFF. LIGHT AND

ALARM ON OUTDOOR UNIT TO BE

RATED FOR EXTERIOR USE.

1-1/4" HW

1-1/4" CW

INSTANTANEOUS

WATER HEATER

FINISHED WALL

WALL BOX

FLANGE

WALL CLAMP (IF

USED)

INLET CONNECTION

INSIDE BACK OF WALL

ALL QUICK DISCONNECT COUPLINGS

AND FITTINGS SHALL MATCH OWNER'S

EXISTING EQUIPMENT AND SHALL BE

VERIFIED

REGULATOR

5-150 PSI, MAX FLOW 140 CFM

1/2"

1/2" QUICK CONNECT

COUPLINGS

1"

BALL VALVE

(TYP.)

PRESSURE GAUGE

1/2"

1/2" QUICK CONNECT

COUPLINGS

REGULATOR

5-150 PSI, MAX FLOW 140 CFM

PRESSURE GAUGE

DIRT LEG

NON-SHRINK GROUT

FLOOR DRAIN OR

FLOOR SINK

FINISHED FLOOR

"P" TRAP

REFER PLANS

FOR SIZES

WASTE TRAP SEAL TO BE

PROVIDED WITH ALL FLOOR

DRAINS AND FLOOR SINKS.

HANGER ROD

LOCKING NUT

SUPPORT NUT

INSULATION

PIPE

HEAVY DUTY

CLEVIS HANGER

14 GAGE SHIELD 18" LONG TO

PROTECT INSULATION

TO STRUCTURE

DOMESTIC COLD

WATER (REFER TO

PLAN FOR SIZES)

DOMESTIC COLD

WATER (REFER TO

PLAN FOR SIZES)

BALL VALVE (TYP.)

UNION (TYP.)

PRESSURE GAUGE

(TYP.)

PRESSURE REDUCING

VALVE SET TO 70PSI

REDUCED PRESSURE

BACKFLOW PREVENTER

STRAINER M

WATER METER

DOMESTIC

HOT WATER

BALL VALVE

CHECK VALVE

WHADOMESTIC COLD

WATER (REFER TO

PLAN FOR SIZES)

MB-1

INSTANTANEOUS

WATER HEATER

TEST COCKS

STRAINER

FOR CONNECTION TO

MECHANICAL EQUIPMENT,

REFER TO PLANS FOR SIZING

DRAIN TO SPILL INDIRECTLY

OVER NEAREST FLOOR SINK

AIR GAP FITTING SIZE

PER BACKFLOW

PREVENTER SIZE

REDUCED PRESSURE ZONE

ASSEMBLY WITH STRAINER

BALL VALVE

TYPICAL

BV

SINGLE LAVATORY OR SINK

REFER TO PLAN FOR

FIXTURE CALLOUT.

DOMESTIC COLD

WATER (REFER TO

PLAN FOR SIZES) BV

TYPICAL CHASE BRANCH LINE

AND FIXTURES. REFER TO

PLANS FOR CW LINE SIZES

AND FIXTURE CALLOUTS.

DOMESTIC COLD

WATER (REFER TO

PLAN FOR SIZES)

WHA (TYP)

REFER TO PDI-WH 201

AND WATER HAMMER

ARRESTOR SCHEDULE

FOR SIZING.

WHA (TYP)

REFER TO PDI-WH 201

AND WATER HAMMER

ARRESTOR SCHEDULE

FOR SIZING.

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

As indicated

/2

/2

:3

:0 A

M

OSB-P-501

742436

C R

A N

E

IN

D

IA

N

A

12810945

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

D E

T A

IL

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -P

-5

P

L U

M B

IN

G

D E

T A

IL

S

RDS/PJB

ALG

EJA

1629197

NOT TO SCALEA1

EMERGENCY SHOWER UNIT DETAIL

NOT TO SCALEB1

FREEZE PROOF WALL HYDRANT DETAIL

NOT TO SCALEB2

WALL MOUNTED COMPRESSED AIR

DETAIL NOT TO SCALEB4

TYPICAL FLOOR DRAIN AND FLOOR SINK

DETAIL

NOT TO SCALED1

CLEVIS HANGER DETAIL WITH

INSULATION

1/4" = 1'-0"C4

INCOMING DOMESTIC WATER DETAIL

NOT TO SCALEA5

MOP BASIN DOMESTIC WATER DETAIL

NOT TO SCALEA3

REDUCED PRESSURE ZONE

BACKFLOW PREVENTER

NOT TO SCALEC2

WATER HAMMER ARRESTOR DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

OUTLET

DUCTING

AC-1

PRE-FILTER

OIL-WATER

SEPARATOR

DESICCANT

AIR DRYER

30 GALLON

TANK

AC-1

INTAKE DUCT

OIL-WATER

SEPARATOR

AIR

CONDITIONER

DESICCANT AIR

DRYER

CABINET

TRANSFORMER & 120 PANEL

480 PANEL

PRE-FILTER

FLOOR DRAIN

DISCONNECT

SECTION VIEW

PLAN VIEW

30 GALLON TANK

COMPRESSED AIR

CONNECTION POINT

ELECTRIC

HEATER

ELECTRIC

HEATER

AIR

CONDITIONER

8'

0" W

ID

TH

NOTE:

CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL AIR COMPRESSOR COMPONENTS, ACCESSORIES, ETC. IN ORDER TO PROVIDE A COMPLETE AND FUNCTIONAL AIR COMPRESSOR ENCLOSURE AND

COMPRESSED AIR SYSTEM.

12' - 0" LENGTH

NOTE:

CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL AIR COMPRESSOR COMPONENTS, ACCESSORIES, ETC. IN ORDER TO PROVIDE A COMPLETE AND FUNCTIONAL AIR COMPRESSOR ENCLOSURE AND

COMPRESSED AIR SYSTEM.

AC-2

OIL-WATER

SEPARATOR

PRE-FILTER

DESICCANT AIR

DRYER

CONTROLLER

ELECTRIC

HEATER

AIR

CONDITIONER

CABINET

AIR

CONDITIONER

PRE-FILTER

OIL-WATER

SEPARATOR

DESICCANT

AIR DRYER

30 GALLON TANK

ELECTRIC

HEATER

AC-2

INTAKE DUCT

PLAN VIEW

SECTION VIEW

20' - 0" LENGTH

OUTLET

DUCTING

90° EXHAUST

HOOD

8'

0" W

ID

TH

480 PANEL

TRANSFORMER

& 120 PANEL

DISCONNECT

480 PANEL

TRANSFORMER

& 120 PANEL

OUTLET DUCT

TO ROOF

COMPRESSED

AIR CONNECTION

POINT

COMPRESSED

AIR CONNECTION

POINT

30 GALLON

TANK

CONDENSATE TO DRAIN TO FLOOR

DRAIN IN EQUIPMENT. COORDINATE

CONDENSATE DISCHARGE

LOCATION WITH FLOOR DRAIN

SHOWN ON CIVIL PLANS.

1"∅ THREADED PIPE

PROVIDE PIPE STANCHION

SADDLE (MSS SP-58 TYPE 37)

CONTINUOUS INSULATION

THROUGH PIPE SUPPORT

INSULATION SADDLES "U" BOLT OR SIMILAR PIPE

CLAMP.

WALL

1/4"x6"x6" PLATE

PIPE SUPPORT

SCREWED TO WALL

INSULATED PIPE WITH

PROTECTION SHIELD AT

CLAMP LOCATIONS. MAINTAIN

SPECIFIED SLOPE.

NOTE: IF PIPES ARE LOCATED OVER CONCRETE, THE OFFSET CLAMPS MAY

BE DIRECTLY ATTACHED WITHOUT THE TREATED LUMBER SUPPORT.

PROVIDE REMOVABLE 16 GAUGE

ALUMINUM TREADPLATE FOR

PROTECTION FROM

MAINTENANCE TRAFFIC

OFFSET PIPE CLAMP ATTACH TO 4 x 4

TREATED LUMBER

SUPPORT

STAND

ROLLER

LOCKING NUT

HANGER ROD

PIPE

INSULATION (NOT

VAPOR BARRIER)

BOLT PIPE ROLLER TO

CHANNEL

14 GAUGE INSULATION

SHIELD. MIN. 18" LONG

PIPE SADDLE AT

LEAST 18" LONG

PIPE NO

INSULATION

VAPOR BARRIER

INSULATION

6" CHANNEL

C TO C

MAX SPACING 42"

L L

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

As indicated

/2

/2

:3

:0 A

M

OSB-P-502

742437

C R

A N

E

IN

D

IA

N

A

12810946

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

D E

T A

IL

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -P

-5

P

L U

M B

IN

G

D E

T A

IL

S

RDS/PJB

ALG

EJA

1629197

NOT TO SCALEA1

TYPE 1 AIR COMPRESSOR ENCLOSURE

DETAIL

NOT TO SCALEA3

TYPE 2 AIR COMPRESSOR ENCLOSURE

DETAIL

NOT TO SCALED3

WALL MOUNTED PIPE SUPPORT DETAIL

NOT TO SCALED1

GRADE MOUNTED PIPE SUPPORT DETAIL

NOT TO SCALED2

TRAPEZE HANGER DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

/2

/2

:3

:1 A

M

OSB-P-601

742438

C R

A N

E

IN

D

IA

N

A

12810947

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

S C

H E

D U

L E

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -P

-6

P

L U

M B

IN

G

S C

H E

D U

L E

S

RDS/PJB

ALG

EJA

1629197

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE

MINIMUM CONNECTION SIZE

DESCRIPTION

SS V CW HW TW

BFP-1 BUILDING BACKFLOW PREVENTER 2" REDUCED PRESSURE ZONE BACKFLOW PREVENTER WITH STRAINER, AIR GAP FITTING, AND QUARTER TURN BALL VALVES.

ESE-1 EXTERIOR EMERGENCY SHOWER / EYEWASH 3" 2"

1 1/4" NON-FREEZE, EXTERIOR SAFETY SHOWER WITH EYE WASH, GALVANIZED STEEL PIPING, PLASTIC SHOWERHEAD AND BOWL, AUDIBLE ALARM AND STROBE, AND NEMA 4X WEATHERPROOF

CONTROLS ENCLOSURE. PROVIDE LOCKABLE SHUTOFF VALVE LOCKED IN THE NORMALLY OPEN POSITION.

ESE-2 EMERGENCY SHOWER / EYEWASH

1 1/4" PROVIDE SHOWER WITH EYE-FACE WASH, GALVANIZED STEEL PIPING, PLASTIC SHOWERHEAD AND BOWL, AUDIBLE ALARM AND STROBE, AND NEMA 4X WEATHERPROOF CONTROLS

ENCLOSURE. PROVIDE LOCKABLE SHUTOFF VALVE LOCKED IN THE NORMALLY OPEN POSITION.

EWC-1 ELECTRIC WATER COOLER 1 1/4" 1 1/4" 1/2" BI-LEVEL ELECTRIC WATER COOLER WITH BOTTLE FILLER

FCO FLOOR CLEANOUT SIZE SAME AS CONNECTED PIPING. SEE FLOOR PLANS AND ISOMETRICS FOR SIZING; PROVIDE WITH TRAFFIC RATED COVER.

FD-1 FLOOR DRAIN 2" 1 1/2" CAST IRON ADJUSTABLE COLLAR AND 7"ø NICKEL BRONZE STRAINER.

FD-2 FLOOR DRAIN 3" 2" CAST IRON ADJUSTABLE COLLAR AND 7"ø NICKEL BRONZE STRAINER.

FS-1 FLOOR SINK 4" 2" 12" x 12" x 8" DEEP FLOOR SINK WITH HEAVY DUTY GRATE AND SEDIMENT BUCKET.

HB-1 HOSE BIBB 3/4" WALL MOUNTED WITH VACUUM BREAKER

IB-1 ICE MAKER BOX 1/2" WALL MOUNTED ICE MAKER BOX WITH QUARTER TURN HANDLES

LAV-1 LAVATORY 1 1/4" 1 1/4" 1/2" 1/2" WALL HUNG WITH 0.5 GPM MANUAL FAUCET. MOUNT UNIT WITH TOP OF BOWL 34 INCHES AFF.

MSB-1 MOP SINK BASIN 3" 2" 1/2" 1/2" 24"X24"X12" TERRAZZO MOP SINK WITH HOSE BRACKET, HOSE, STAINLESS STEEL CAPS, AND STAINLESS STEEL WALL GUARD.

SK-1 KITCHEN SINK 1 1/2" 1 1/4" 1/2" 1/2" SINGLE 19"X19"X6" BOWL, STAINLESS STEEL, TOP MOUNT; 1.5 GPM MANUAL FAUCET WITH SINGLE LEVER.

ST-1 SAND TRAP 4" 24"X24" HEAVY DUTY GRATE. 60 GALLON CAPACITY.

WC-1 WATER CLOSET 4" 2" 1" WALL HUNG WITH MANUAL 1.1 GPF FLUSH VALVE. MOUNT UNIT WITH TOP OF BOWL 18 INCHES AFF.

WCO WALL CLEANOUT SIZE SAME AS CONNECTED PIPING. SEE FLOOR PLANS AND ISOMETRICS FOR SIZING; PROVIDE WITH CHROME WALL PLATE

WH-1 WALL HYDRANT 3/4"

CHROME-PLATED QUARTER TURN NON-FREEZE AUTOMATIC DRAINING HYDRANT, 3/4" MALE HOSE THREAD OUTLET CONNECTION, INTEGRAL VACUUM BREAKER, INTEGRAL SERVICE SHUTOFF

VALVE, DUAL CHECK VALVE, "T" HANDLE KEY.

INSTANTANEOUS WATER HEATER SCHEDULE

MARK SERVES LOCATION FLOW CAPACITY

TEMPERATURE

RISE @ FLOW

OUTLET

TEMPERATURE

ELECTRICAL

NOTESMCA VOLTAGE PHASE

IWH-01 KITCHEN SINK 111 - BREAK ROOM 1.5 GPM 20.0 kW 61 °F 110 °F 24 A 460 V 3 3

IWH-02 MOP SINK BASIN 114 - JANITOR 2.2 GPM 24.0 kW 68 °F 120 °F 29 A 460 V 3 3

IWH-03 LAVATORY 115 - TOILET 0.5 GPM 4.1 kW 56 °F 105 °F 20 A 208 V 1 3

IWH-04 LAVATORY 116 - TOILET 0.5 GPM 4.1 kW 56 °F 105 °F 20 A 208 V 1 3

IWH-05 EMERGENCY EYEWASH / SHOWERS 101 - LTV & CANISTER MAINTENANCE AREA 20.0 GPM 96.0 kW 33 °F 85 °F 116 A 460 V 3 1,2,3,4

IWH-06 EMERGENCY EYEWASH / SHOWERS 101 - LTV & CANISTER MAINTENANCE AREA 20.0 GPM 96.0 kW 33 °F 85 °F 116 A 460 V 3 1,2,3,4

WATER HAMMER ARRESTOR SCHEDULE

MARK FIXTURE UNITS PIPE SIZE HEIGHT DIAMETER NOTES

WHA-A 1-11 3/4" 2.62" 3.25" 1

WHA-B 12-32 1" 2.97" 3.25" 1

WHA-C 33-60 1" 3.59" 3.25" 1

WHA-D 61-113 1" 5.14" 3.25" 1

WHA-E 114-154 1" 5.52" 3.25" 1

WHA-F 155-330 1" 6.67" 3.25" 1

AIR COMPRESSOR SCHEDULE

MARK SERVES TYPE

FREE AIR

DELIVERY

MAXIMUM

PRESSURE HP

ELECTRICAL DATA

WEIGHT NOTESFLA VOLTAGE PHASE

AC-1 101 - LTV & CANISTER MAINTENANCE AREA ROTARY SCREW 58 CFM 145 psi 15 hp 27 A 460 V 3 1,200 lb 1,2,4,5

AC-2 LRSE BUILDING ROTARY SCREW 108 CFM 200 psi 50 hp 65 A 460 V 3 2,700 lb 1,2,3,4,5

NOTES:

1. LOCATED OUTSIDE OF BUILDING. PROVIDE WITH VENTED AND HEATED ENCLOSURE. ENCLOSURE TO HAVE MANUFACTURER'S RECOMMENDED CLEARANCE ON ALL SIDES FOR MAINTENANCE. ENCLOSURE TO

HAVE ALL REQUIRED COMPONENTS TO PROVIDE A COMPLETE FACTORY BUILT COMPRESSED AIR SYSTEM.

2. PROVIDE WITH DESICCANT AIR DRYER.

3. UNIT TO BE LOCATED NEAR LRSE. PROVIDE WITH QUICK CONNECT TO ENCLOSURE FOR USERS TO CONNECT / DISCONNECT AS NEEDED. REFER TO CIVIL PLANS FOR LOCATION OF AC-2.

4. REFER TO OSB-M-706 FOR AIR COMPRESSOR SEQUENCE OF OPERATIONS.

5. PROVIDE UNITS WITH PRE-FILTERS AND POST FILTERS. ISO CLASS TO BE 2:2:1. (PARTICLES, DEW POINT, OIL).

NOTES:

1. PROVIDE WITH ACCESS PANEL.

NOTES:

1. PROVIDE WITH NON-FUSED DISCONNECT.

2. PROVIDE FULLY MODULATING OPERATION.

3. PROVIDE WITH BUILT-IN SCALD PROTECTION

4. PROVIDE WITH NEMA 4 RATED ENCLOSURE.

AIR DRYER (AD) SCHEDULE

MARK SERVES TYPE PURGE AIR

-40°F INLET

CAPACITY

ELECTRICAL DATA

WEIGHT NOTESFLA VOLTAGE PHASE

AD-1 AC-1 DESICCANT 13 CFM 90 CFM 5 A 120 V 1 500 lb 1,2

AD-2 AC-2 DESICCANT 29 CFM 200 CFM 5 A 120 V 1 800 lb 1,2

NOTES:

1. PROVIDE UNITS WITH MANUAL SHUTOFF TO SHUT OFF AIR COMPRESSOR ASSEMBLY SO THAT AIR DRYER IS NOT PURGING AIR DURING NON-USE TIMES.

2. PROVIDE WITH OIL WATER SEPARATOR. AIR DRYER AND RECEIVER TANK CONDENSATE SHALL DISCHARGE THROUGH OIL WATER SEPARATOR BEFORE DISCHARGING TO

SANITARY SEWER FLOOR DRAIN.

FAN SCHEDULE

MARK TYPE CFM

ESP (IN.

WC)

FAN

RPM

ELECTRICAL

NOTESFLA V PH HZ

F-1 INLINE 150 1.00 2715 2.1 120 1 60 1

NOTES:

1. PROVIDE RADON FAN WITH EC MOTOR

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

IWH

ESE-1

HB-1

IWH

05ESE-2

BFP-1

HB-1

WH-1

WH-1

WH-1

IWH

IB-1

IWH

IWH

IWH

WH-1

WC-1

WC-1

LAV-1

LAV-1

1 1/4"Ø DCW

3/4"Ø DCW

3/4"Ø DCW

3/4"Ø DCW

3/4"Ø DCW

2"Ø DCW

1 1/4"Ø DCW2"Ø DCW

3/4"Ø DCW

2"Ø DCW

1 1/2"Ø DCW

3/4"Ø DCW

1 1/2"Ø DCW

1 1/4"Ø DCW

3/4"Ø DCW

1/2"Ø DCW

3/4"Ø DCW

1 1/4"Ø DCW

1/2"Ø DHW

1/2"Ø DCW

1/2"Ø DCW1/2"Ø DCW

1 1/4"Ø DHW

HB-1

3/4"Ø DCW

2"Ø DCW

1 1/2"Ø DCW

SK-1

EWC-1

1/2"Ø DCW

MSB-1

2" DOMESTIC WATER

METER WITH DIRECT READ

REGISTER

PROVIDE LOCKABLE

BALL VALVE

PROVIDE LOCKABLE

BALL VALVE

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

/2

/2

:3

:1 A

M

OSB-P-901

742439

C R

A N

E

IN

D

IA

N

A

12810948

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

I S

O M

E T

R

IC

S

N S

A C

R A

N E

P -4

U

N D

E R

W A

T E

R L

A U

N C

H T

E S

T F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

O S

B -P

-9

P

L U

M B

IN

G

I S

O M

E T

R

IC

S

RDS/PJB

ALG

EJA

1629197

A1

DOMESTIC WATER PIPING ISOMETRIC

NOT TO SCALE

NTS

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R F

P P

H A

S E

S

U B

M

IS

S

IO

N

/0

/2

4"Ø SSESE-1

ST-1

FCO

4"Ø SS

4"Ø SS

4"Ø SS

FS-1

ESE-2

4"Ø SS

FD-1

WC-1

WC-1 FD-2

FCO

LAV-1

LAV-1

3/4"Ø CD

3/4"Ø CD

3/4"Ø CD

3/4"Ø CD

3/4"Ø CD

4"Ø SS

WALL HUNG HVAC UNIT

PROVIDED BY MECHANICAL

CONTRACTOR. REFER TO

MECHANICAL PLANS FOR

ADDITIONAL INFORMATION.

WALL HUNG HVAC UNIT

PROVIDED BY MECHANICAL

CONTRACTOR. REFER TO

MECHANICAL PLANS FOR

ADDITIONAL INFORMATION.

ABOVE CEILING HVAC UNIT

PROVIDED BY MECHANICAL

CONTRACTOR. REFER TO

MECHANICAL PLANS FOR

ADDITIONAL INFORMATION.

2"Ø V

3"Ø V

3"Ø V

2"Ø V

3"Ø V

2"Ø V

2"Ø V

2" Ø

V

1 1/4"Ø V

1 1/2"Ø SS

4"Ø SS

4"Ø SS

3"Ø SS

FD-1

3"Ø V

2"Ø V

1 1/2"Ø V

4"Ø SS

4"Ø SS

4"Ø SS

SK-1

4"Ø SS

EWC-1

1 1/4"Ø SS

MSB-1

FCO

4"Ø SS

SANITARY CONNECTION TO

FLOOR DRAIN IN AC-1

ENCLOSURE.

3/4"Ø CD

FD-2 3"Ø SS

1 1/2"Ø SS

3"Ø SS

3"Ø SS

3"Ø SS

3/4"Ø CD

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

1 2 3 4 5

O P

E R

A T

IO

N

S S

U P

P O

R T

B U

IL

D

IN

G

M

ID

L A

N T

C I

C O

R E

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

APPROVED BY SHANE A. FRINK

CTF TEST SYSTEM INTEGRATOR

NSWC CRANE VIA EMAIL

2/24/2020

/2

/2

:3

:1 A

M

OSB-P-902

742440

C R

A N

E

IN

D

IA

N

A

12810949

N40085-19-R-9186

WE WE AB

P L U

M B

IN

G

I…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .