1629197dwgVol1_Sheet122-135_C.pdf
PDF 16 MB Posted
- Solicitation number
- N4008519R9186
About this file
This federal solicitation seeks design and construction services for an Underwater Launch Test Facility project. Key details include constructing a launch pit, operational support building, warehouse, water treatment facility, and mechanical and electrical building to support submerged launch testing. Additional site facilities include pavements, utilities, and environmental mitigation. Construction will be phased, with storage pad completion in seven months and overall project completion in eighteen months. The Naval Facilities Engineering Command is the awarding agency.
View the file
Other files
Show 40 more
Latest 50 of 115 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F I L E
N
A M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d w g
Y O
U T
M
E
U
T F
C
P
O
T T
E D
T u e s d a y
A p r i l p m
S E
R p a t e l d
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-501
12810631
AS NOTED
KM MD JK
M I N
30"
NOTES:
1. RUNGS MUST BE STEEL REINFORCED POLYPROPYLENE.
2. MANHOLE RUNGS MUST BE INSTALLED FACING TRAFFIC WHEN STRUCTURE IS IN A TRAVEL LANE, AND
PERPENDICULAR TO TRAFFIC FLOW WHEN STRUCTURE IS INSTALLED ON ROADWAY CENTERLINE.
3. REFER TO GRADING/UTILITY PLAN FOR PIPE LOCATION.
4. MANHOLE COVERS MUST HAVE THE UTILITY CAST INTO THE SOLID COVER (SEWER, STORM, ELECTRIC, WATER, COMMUNICATIONS) AS APPLICABLE.
FINAL GRADE
PRE-CAST GRADE RINGS (2 MAX.)
PRE-CAST ECCENTRIC CONE SECTION
TWO SEPARATE COATS OF APPROVED BITUMASTIC
WATERPROOFING COMPOUND SHALL BE APPLIED
PER MANUFACTURER'S INSTRUCTIONS, TO ENTIRE
STRUCTURE
PRE-CAST RISER SECTIONS
(AS REQUIRED)
PRE-CAST MANHOLE SECTIONS TO BE CONSTRUCTED
& REINFORCED IN ACCORDANCE W/ ASTM
SPECIFICATION C-478-90b.
RUBBER GASKET & CEMENT GROUT AT EACH JOINT IN
CONFORMANCE WITH ASTM C-443.
PRE-CAST BASE SECTION
COMPACTED AGGREGATE,
INDOT NO. 53, BASE
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT
SPECIFICATIONS
MANHOLE RUNGS @ 12" O.C.
48" MIN.
5" (MIN.)
T
O
V A
R I E
S
12" MIN.
CONCRETE FILL
2" MIN.
SMOOTH CONCRETE CHANNEL - DEPTH EQUAL TO 0.80
TIMES DIA. OF MAIN SEWER FOR SIZES LESS THAN 16"
AND 0.50 TIMES DIA. OF MAIN SEWER FOR SIZES 16"
AND LARGER. STORM AND SANITARY MH ONLY.
PLAN
3000 PSI CONCRETE
4"
4"
4" 4"
10' MIN. 10' MIN.
NEW SANITARY SEWER
MAIN
WATER MAIN
A
UTF-C-501UTF-C-501
CAST IRON MANHOLE FRAME AND COVER
NEENAH FOUNDRY PATTERN NO. R-1556 OR
APPROVED EQUAL
D E
P A
R T
M E
O
T
H
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
C
R A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
6"
B3
PRE-CAST MANHOLE DETAIL
NOT TO SCALE
B4
SANITARY SEWER ENCASEMENT
NOT TO SCALE
COMPACTED AGGREGATE,
INDOT NO. 53, BASE
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT
SPECIFICATIONS
C
L
NOTES:
1. PROVIDE ONE TRACER WIRE BOX AT MAXIMUM INTERVALS OF 1,000'.
2. PROVIDE A MINIMUM OF 12" OF SLACK FOR EACH TRACER WIRE IN THE VALVE
BOX.
M I N
M I N
3'
M
I N
C1
VENT DETAIL
NOT TO SCALE
A1
TRACE WIRE FOR HDPE SANITARY FORCE MAIN DETAIL
NOT TO SCALE
3000 PSI CONCRETE
EXISTING GRADE
3" SCH 40 WELDED STEEL
PRIMED & PAINTED GREEN
3" MNPT GALVANAIZED CAP
CLASS 150 WITH INSECT
SCREEN
180° RETURN BEND
1" SCH 80 PVC VENT
FROM CHAMBER
1" X 3" PVC TO GALVANIZED
ADAPTOR FLEXIBLE
COUPLING
TRACER WIRES
CAST IRON VALVE BOX
TOP
LID SURFACE
FRAME
MORTAR
SET IN
SEE UTF-C-508/A4 FOR
FRAME AND COVER
INSTALLATION
REQUIREMENTS
ENCASEMENT - SECTION A-A
0.1" DIAMETER BARE
COPPER OR ALUMINUM WIRE
TAPE TO PIPE AT 20 FT.
INTERVALS
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-502
12810632
AS NOTED
KM MD JK
M
I N
M
I N
22" MIN.
6" MIN.
6" MIN.
M
I N
CONCRETE PAD
HEATER / ELECTRICAL
CONNECTION
ENCLOSURE FLANGE
C1
ENCLOSURE FOR DETACHABLE WATER SERVICE
NOT TO SCALE
1.5" COPPER WATER
SERVICE
1" DIELECTRIC COPPER
TO STEEL TRANSITION
COUPLING
1" SCH 40 GALVANIZED
PIPE MNPT
1" FNPT GALVANIZED
90° ELBOW
1" SCH 40 GALVANIZED
PIPE MNPT
1" FNPT
BALL VALVE
1" SCH 40 GALVANIZED
PIPE MNPT
1" FNPT GALVANIZED
90° ELBOW
1" SCH 40 GALVANIZED
PIPE MNPT
HOT BOX MODEL # HB.75
OR APPROVED EQUAL
10" W X 18" L X 23" H
(INTERIOR) INSULATED
AND HEATED ENCLOSURE
WITH FLIP TOP LID.
SEE NOTE 1.
M
I N
M
I N
CONCRETE PAD
M
I N
NOTES:
1. ATTACH ENCLOSURE TO CONCRETE PAD IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS.
2. DRILL THROUGH ENCLOSURE WALL FOR PIPE
PENETRATION. ROUTE PIPING AS REQUIRED TO ENSURE
THE HOLE IS BELOW FLIP TOP LID. HOLE DIAMETER MUST
NOT EXCEED 1
". SEAL GAPS AS REQUIRED.
3. TO PROVIDE THE REQUIRED 18" PIPE HEIGHT DIMENSION
THE PIPE MAY NEED TO EXIT THE REAR OF THE
ENCLOSURE. PROVIDE ADDITIONAL FITTINGS AND ROTATE
THE ENCLOSURE AS REQUIRED SO THE EXITING PIPE IS IN
THE DIRECTION OF THE LAUNCH PIT.
1" FNPT BALL
VALVE WITH HOSE
DRAIN.
1" SCH 40
GALVANIZED
PIPE MNPT.
SEE NOTE 2
1" GALVANIZED
FNPT CAP.
TOP AT GRADE
TOP ABOVE GRADE
1'x1'x6" SUMP
MANHOLE FRAME AND COVER, SEE
PRE-CAST MANHOLE DETAIL UTF-C-501/B3
NOTE:
ALL METALLIC PIPING WITHIN MANHOLE MUST
BE PAINTED, UNLESS FACTORY COATED.
GRADE RING FOR
ADJUSTMENT
COMBINATION AIR /
VACUUM VALVE
3" HDPE FORCE MAIN /
8" WATER MAIN
STAINLESS STEEL PIPE SUPPORT,
ONE ON EACH SIDE OF THE FLANGE
OUTLET SADDLE
3"x2" FLG. DIP TEE W/ 2" BLIND
FLANGE FACE, TAP FOR 1"
1" GATE VALVE
UNION
1" BALL VALVE
" BALL VALVE
SIZE OPENING FOR ACTUAL PIPE
OUTSIDE DIAMETER AND APPROVED
LINK SEAL
1/4" DRAIN LINE AND CHECK VALVE
1" SCH 80 PVC TO VENT
LINK SEAL (TYP)
PRECAST MANHOLE, SEE
PRE-CAST MANHOLE DETAIL
UTF-C-501/B3
ECCENTRIC CONE
SECTION
12" MAX.
6" MIN.
12" MAX.
12" (TYP.)
M I N
30" MIN.
24" MIN.
12" MIN.
1" 316 S.S. PIPE
A1
REQUIRED SEPARATION BETWEEN WATER MAINS AND SANITARY SEWERS
NOT TO SCALE
1. WATER MAINS MUST BE CONSTRUCTED 10' HORIZONTALLY FROM SANITARY SEWERS.
2. WATER MAINS MUST BE LOCATED BENEATH SANITARY SEWER ONLY IF SUFFICIENT VERTICAL CLEARANCE
ABOVE SEWER DOES NOT EXIST. IN EITHER CASES A MINIMUM OF 18" VERTICAL SEPARATION MUST BE
PROVIDED.
3. WATER MAIN AND SEWER MAINS MUST BE OF WATER TIGHT CONSTRUCTION.
1'-0"
MIN.
SYMMETRICAL ABOUT ℄
OUTSIDE
FACE
OF PIPE ℄ OF NEW
WATER MAIN
℄ OF NEW
WATER MAIN
GROUND SURFACE
4. WATER MAINS WITH LESS THAN 48" COVER MUST BE INSTALLED WITH THE APPROVAL OF THE CONTRACTING
OFFICER HOWEVER, IN NO CASE SHALL THIS BE LESS THAN 42"
OUTSIDE FACE
OF PIPE
1'-0"
MIN.
SYMETRICAL ABOUT ℄
℄ OF NEW
WATER MAIN
℄ OF NEW
WATER MAIN
℄ OF NEW
WATER MAIN
GROUND SURFACE
M
I N
U N
L E
T
E D
A4
SANITARY DROP MANHOLE DETAIL
NOT TO SCALE
OUTSIDE FACE
OF PIPE
℄ OF NEW
WATER MAIN
OUTSIDE FACE
OF PIPE
POWER CONDUIT
WALL MOUNTED
HEATER
NOTE:
REPEAT OUTSIDE DROP CONFIGURATION AS NEEDED FOR ALL PIPES ENTERING MANHOLE
AT ELEVATION.
45° WYE BRANCH
(TEE IF DROP IS
LESS THAN 3'- 6")
FOR CONSTRUCTION ABOVE THIS
POINT, SEE STANDARD PRECAST
MANHOLE DETAIL
NON-SHRINK
GROUT OR
APPROVED
EQUAL
BRICK HALF
WAY UP
"O"- RING WATERTIGHT
RUBBER GASKET JOINT
PER ASTM - 443
PRECAST PIPE OPENING
WITH INTEGRALLY CAST
FLEXIBLE PIPE CONNECTOR
ASTM-923
FIRST PIECE 1'- 4"
MAXIMUM LENGTH
OUTGOING PIPE
6" CRUSHED
STONE
INCOMING PIPE
SEE NOTE
BEND AS REQUIRED
VARIABLE LENGTH
6" MIN. CONCRETE
ENCASEMENT
90° ELBOW
CLASS "C" CONCRETE
UNDISTURBED SOIL
BENCHING
D
D
C4
COMBINATION AIR / VACUUM RELEASE VALVE
NOT TO SCALE
18"
SEE NOTE 3
ALTERNATE PIPE
ALIGNMENT
1.5" X 1" REDUCER
1" COPPER STUB PIECE
TRENCH TYPE WIDTH DEPTH COVER
UTILITY TYPE 1 24" 14" (MIN, PER PLAN) NEENAH R-4999-HX TYPE D OR APPROVED EQUAL
UTILITY TYPE 2 48" 14" (MIN, PER PLAN) NEENAH R-4999-OX TYPE D OR APPROVED EQUAL
UTILITY TYPE 3 24" 26" (MIN, PER PLAN NEENAH R-4999-HX TYPE D OR APPROVED EQUAL
DRAINAGE 12" 12" (MIN, PER PLAN) NEENAH R-4990-DX TYPE A OR APPROVED EQUAL
F I
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-503
12810633
AS NOTED
KM MD JK
(5) #5 CONTINUOUS BARS
#5 BARS @ 12" O.C. EACH WAY
8"
TYP.
BOTTOM TRENCH ELEV
VARIES, SEE CIVIL PLAN
C
L E
A R
#5 BARS @ 12" O.C.
EA WAY TOP & BOTTOM
FINISH GRADE
SEE CIVIL
PLAN
6" COMPACTED AGGREGATE, INDOT NO. 53, BASE
T
Y P
8" (TYP.);
18" UNDER SURFACE
MOUNTED BOLLARDS
SEE CIVIL PLAN
#5 BARS @ 15" O.C.
EA WAY TOP & BOTTOM
CHAMFER EXPOSED
EDGES (TYP.)
T
H I C
K
SEE NOTE 1
S E
E
N
O T
E
FINISH GRADE
SEE CIVIL
PLAN
SEE CIVIL PLAN
8" (TYP.);
18" UNDER SURFACE
MOUNTED BOLLARDS
S E
E
C
I V
A
N
#4 BAR CONTINUOUS
(TYP. BOTH SIDES)
#4 BAR CONTINOUS
(TYP. BOTH SIDES)
NOTES:
1. PROVIDE EXPANSION JOINTS, 1/2" WIDE PREMOLDED BITUMINOUS MATERIAL AGAINST ALL HARD SURFACES.
2. PROVIDE JOINTS PER DETAILS ON LPC-S-503.
3. PROVIDE PIPE SLEEVES OR OPENINGS IN CONC PAD FOR ANY UTILITIES AS PER EACH DISCIPLINES DRAWINGS.
4. REFER TO DWG UTF-C-003 FOR CONCRETE NOTES.
NOTES:
1. PROVIDE EXPANSION JOINTS, 1/2" WIDE PREMOLDED BITUMINOUS MATERIAL AGAINST ALL HARD SURFACES.
2. PROVIDE JOINTS PER DETAILS ON LPC-S-503.
3. PROVIDE PIPE SLEEVES OR OPENINGS IN CONC PAD FOR ANY UTILITIES AS PER EACH DISCIPLINES DRAWINGS.
4. REFER TO DWG UTF-C-003 FOR CONCRETE NOTES.
CHAMFER NOT REQUIRED IF
AGAINST BUILDING (TYP.)
SLOPE PER
PLAN OR 2%
SEE NOTE 1
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
6"
TYP.
C1
TYPICAL CONCRETE APRON DETAIL
NOT TO SCALE
A1
TYPICAL CONCRETE PAD
NOT TO SCALE
6" COMPACTED AGGREGATE, INDOT NO. 53,
BASE
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
6"
TYP.
6"
3/4" X 3/4" SEALANT (TYP.)
6" COMPACTED AGGREGATE, INDOT NO. 53, BASE
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
NOTES:
1. TRENCH DEPTH AND WIDTH SHALL BE:
2. PROVIDE 45° UTILITY TRENCH INTERSECTION COVERS NEENAH R-4990-HX TYPE D, 45 DEGREE AND R-4990-0X TYPE D, 45 DEGREE OR APPROVED EQUAL WHERE SHOWN ON PLANS.
3. PROVIDE (32) 1/4" THICK X 24" LONG X 26" WIDE STAINLESS STEEL DIAMOND PLATE SPARE/REPLACEMENT COVERS. COVERS MUST HAVE SLOTTED HOLES FOR BOLTED CONNECTION TO
TRENCH FRAME. ADD SHIM SUPPORTS AT EACH BOLTED CONNECTION SO THE COVER IS FLUSH WITH THE SURROUNDING GRADE.
5'-0" LIMIT OF GEOGRID
(TYP.)
40'-0"
COMPACTED AGGREGATE,
INDOT NO. 53, BASE (TYP.)
HARDWOOD CRANE MAT
12" THICK, 96" WIDE X 40' LONG SECTIONS
BIAXIAL GEOGRID
(3 LAYERS)
EXISTING SHALE/SANDSTONE
(310' LONG)
CONCRETE CRANE PAD
CURB (TYP.)
A3
CRANE PAD TYPICAL DETAIL (SYMMETRICAL)
NOT TO SCALE
A4
2'-0"
#5 @ 12"
TOP & BOTTOM
3 #5 BARS
TOP & BOTTOM
EXISTING SUBGRADE
PAVEMENT
BOX (TYP.)
CONCRETE CRANE PAD CURB
REINFORCEMENT DETAIL
NOT TO SCALE
NOTE:
1. CONTRACTION JOINTS IN CONCRETE CRANE PAD CURB MUST
BE PROVIDED AT 30' MAXIMUM. EXPANSION JOINTS MUST BE
PROVIDED AT 90' MAXIMUM.
T
H I C
K
24"
TYP.
24"
TYP.
FILTER FABRIC
INV. 716.25
8" SOLID WALL PVC
8" PERFORATED PVC
COMPACTED
INDOT COURSE
AGGREGATE # 2
EL. PER PLANS
TRENCH DRAIN
PER PLANS
719.00
X
718.50
X
1%
V A
R I E
S
C4
UTILITY AND DRAINAGE TRENCH DETAIL
NOT TO SCALE
SEE ENLARGEMENT
1 3/4"
ENLARGEMENT
SEALANT
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-504
12810634
AS NOTED
KM MD JK
5.0' 5.0' 5.0' 5.0' 3.5'
3.5' 3.0'
10.0' 19.0'
DUMPSTERDUMPSTERRECYCLING
30.0'
A1
TRASH ENCLOSURE DETAIL
NOT TO SCALE
C O
N C
A
P R
O N
CHAIN LINK SWING GATE
(UTF-C-504/C1)
6"
TYP.
6" (TYP.)
LOCKABLE
LATCH
STRIKE STRAP
2" MESH NO. 9 GAUGE
ZINC COATED STEEL WIRE
MESH (TYP.)
CENTER DROP ROD AND
DROP ROD ASSEMBLY
W/ PVC SLEEVE
1 1/2"
2" UPRIGHT
GALVANIZED
SCHEDULE 40 (TYP.)
FINISHED GRADE
1 1/2"
GATE OPENING PER PLAN
DIAGONAL TRUSS ROD
3/8"Ø (TYP.)
GATE HINGE
THREE SETS PER GATE
LEAF WITH NEEDLE-
ROLLER BEARING (TYP.)
POST CAP
TYP. FOR 2
2" POST CAP
TYP. FOR ALL
2" TUBE, GALVANIZED
SCHEDULE 40 (TYP.)
2" GALVANIZED
SCHEDULE 40
UPRIGHTS (TYP.)
GALVANIZED
SCHEDULE
40 POST PER
SPECIFICATIONS
TENSION BAND
(TYP.)
WELDED GATE
(TYP.)
TENSION
BAND (TYP.)
TRUSS ROD
ADJUSTING
UNIT (TYP.)
8"
CONCRETE FOUNDATION
4,000 PSI (TYP.)
EXISTING UNDISTURBED
SOIL / COMPACTED
STRUCTURAL FILL
24"
14' / 12.5'
TAIL (FABRIC NOT SHOWN IN TAIL)FABRIC AREA
2" MIN. DIA, SCHEDULE 40
ZINC COATED UPRIGHT ANY
TOP RAIL
POST TOP
2" SQ B/W ARM TYP.
2" SQ ALUM UPRIGHT
6" OD POST
(TYP. OF 3)
TRUCK ASS'Y
(TYP. OF 2)
ALUM
TRACK/RAIL
2" SQ ALUM
UPRIGHT
CABLE
TRUSS
LATCH
CABLE TRUSS
6" MIN OD POST
2"x4" ALUM
BOTTOM RAIL
2" SQ ALUM
UPRIGHT
TENSION ROD
2", 9 GAUGE ZINC
COATED STEEL
WIRE MESH
CHAIN LINK FABRIC
GUIDE ROLLER ASS'Y
NOTES:
1. FOOTING WIDTH TO BE (4)X POST WIDTH. MINIMUM DEPTH TO BE 48".
2. GATES SHALL BE MANUALLY OPERATED.
3. MATERIAL SIZES SHOWN ARE APPROXIMATE. FINAL DESIGN PER MANUFACTURER.
4. CROSS BRACING NOT TO EXCEED 6'.
5. PROVIDE HEAVY DUTY HINGE/HARDWARE.
A4
7' HIGH, 30'/25' (PER PLAN) WIDE CHAIN LINK CANTILEVER SLIDE GATE
NOT TO SCALE
45' / 37.5'
30' / 25'TO OPEN
GATE PLAN
GATE ELEVATION
4" NOMINAL
CLEARANCE
INSIDE
OUTSIDE
2"
2"
TENSION BAR
TENSION BAND
TERMINAL POST CAP
BRACE BAND
LINE POST TOP
D
I A
G
O
N
B
A
D
Ø
TOP RAIL
END CAP
FABRIC CONTINUED
OVER TOP OF
UPPER RAIL
1 5/8" DIA.
SCHEDULE 40 ZINC-COATED TOP AND BRACE RAIL
2", 9 GAUGE
ZINC-COATED
STEEL WIRE MESH
3 1/2" DIA.
SCHEDULE 40
ZINC-COATED
TERMINAL POST
BRACE BAND FOR
TENSION WIRE
12"
10'-0" MAXIMUM POST SPACING
PLUG END
OF POST
TENSION WIRE
CLIPS
BOTTOM TENSION
WIRE
FENCE TIES
(TYP.)
2 7/8" DIA.
SCHEDULE 40
ZINC-COATED
LINE POSTS
2"
CONCRETE FOUNDATION, 4,000 PSI (TYP.)
NOTES:
1. ZINC COAT ALL MATERIALS.
2. PROVIDE BROWN SLATS WHERE SPECIFIED.
3. FENCE MUST BE SET ON THE BIAS ON SLOPPED TERRAIN. POST SPACING MUST BE
SET TO MAINTAIN ONLY 2" CLEARANCE BETWEEN WIRE MESH AND FINISHED GRADE.
12"
WELDED GATE
FABRIC TIE
SWING GATE
POST CAP (TYP.)
BRACE
BAND (TYP.)
GATE
LATCH
(TYP.)
4" DIA. SCHEDULE
40 ZINC-COATED
END POST (TYP.)
CONCRETE
FOUNDATION
4,000 PSI (TYP.)
NOTES:
1. ZINC COAT ALL MATERIAL.
2. FINAL DESIGN PER FENCE MANUFACTURER.
3. PROVIDE MIN. 5' BETWEEN 3' GATE POST AND SLIDING GATE POST.
2" 9 GAUGE
ZINC-COATED
STEEL WIRE
MESH (TYP.)
16"
2" TUBE,
GALVANIZED
SCHEDULE 40 (TYP.)
C4
7' HEIGHT CHAIN LINK FENCE DETAIL
NOT TO SCALE
3'-0"
BOLLARD
TYPE 2
7' HIGH CHAIN
LINK FENCE
WITH BROWN
SLATS
DUMPSTER / RECYCLING
CONTAINERS (NIC)
CONCRETE PAD
SEE DETAIL
UTF-C-503/A1
CHAIN LINK SWING GATE
WITH BROWN SLATS (TYP.)
TRASH ENCLOSURE SWING GATE
STEEL SUPPORT POST (TYP.)
A2
7' HIGH, 3' WIDE CHAIN LINK GATE DETAIL
NOT TO SCALE
WELDED GATE
FABRIC TIE
SWING GATE
14'-0"
16"
POST CAP (TYP.)
BRACE
BAND (TYP.)
4" DIA. SCHEDULE
40 ZINC-COATED
END POST (TYP.)
CONCRETE
FOUNDATION
4,000 PSI (TYP.)
2" 9 GAUGE
ZINC-COATED
STEEL WIRE
MESH (TYP.)
2" TUBE,
GALVANIZED
SCHEDULE 40 (TYP.)
B2
NOT TO SCALE
GATE
LATCH
(TYP.)
NOTES:
1. ZINC COAT ALL MATERIAL.
2. FINAL DESIGN PER FENCE MANUFACTURER.
3. PROVIDE HEAVY DUTY HINGE/HARDWARE.
7' HIGH, 14' WIDE CHAIN LINK FENCE
SWING GATE DETAIL
NOTES:
1. ZINC COAT ALL MATERIALS.
2. FOOTING WIDTH TO BE FOUR TIMES THE POST WIDTH.
3. PROVIDE KNUCKLE SELVAGE FOR FENCE FABRIC.
4. FINAL DESIGN PER GATE MANUFACTURER.
5. PROVIDE BROWN SLATS.
6. PROVIDE HEAVY DUTY HINGE/HARDWARE.
6"
SEE UTF-C-504/C1
CONCRETE PAD
SEE DETAIL
UTF-C-503/A1
EXPANSION
JOINT
(TYP.)
C1
TRASH ENCLOSURE SWING GATE DETAIL
NOT TO SCALE
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-505
12810635
AS NOTED
KM MD JK
5'-0" OR PER PLAN
4" THICK, 4000 PSI CONCRETE FOR SIDEWALK
COMPACTED AGGREGATE, INDOT NO. 53,
BASE COURSE, 6" THICK
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
NOTE:
1. PROVIDE EXPANSION JOINTS, 1/2" WIDE PREMOLDED
BITUMINOUS MATERIAL AT 15' INTERVALS, AND AGAINST ALL
HARD SURFACES, CONTRACTION JOINTS SPACED AT EQUAL
INTERVALS, 5' MAXIMUM LENGTH, 1/4" BELOW SIDEWALK
SURFACE.
6x6 - W1.4xW1.4 WELDED WIRE
FABRIC (WWF)
COMPACTED AGGREGATE, INDOT NO. 53,
BASE COURSE, 10" THICK
HMA SURFACE COURSE 12.5 MM, 2" THICK
HMA INTERMEDIATE COURSE 25.0 MM, 4" THICK
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
C1
BITUMINOUS PAVEMENT DETAIL
NOT TO SCALE
B1
CONCRETE SIDEWALK DETAIL
NOT TO SCALE
COMPACTED AGGREGATE, INDOT NO. 53, BASE
COURSE, 24" THICK FOR TEST EQUIPMENT PAD
12" THICK FOR GRAVEL DRIVE
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
A1
NOT TO SCALE
5'-8"
3'-0"
6" 1'-0" 1'-0" 6"
3'-0"
CONCRETE
FOUNDATION
3/4" THICK A572 GRADE 50
EMBEDMENT PLATE
3/4" Ø STEEL HEADED
CONCRETE ANCHOR (TYP.)
A
UTF-C-505 UTF-C-505
PLAN
SECTION A-A
3'-0" THICK CONCRETE MAT
FOUNDATION (TYP)
PROVIDE A SMOOTH DOWEL
BARS @ 10" O.C.; GREASE &
PAPER WRAP ONE END
STAGING
FOUNDATION,
UTF-C-503/C1
THICKENED SLAB
AT JOINT,
UTF-C-503/C1
1" ISOLATION
JOINT WITH
SEALENT
B2
NOT TO SCALE
2' (TYP.)
6"
℄ CONCRETE CHANNEL FOR
FUTURE EMBEDDED RAIL
8" SLAB-ON-GROUND
TEST EQUIPMENT PAD, SUBSTATION,
AND GRAVEL DRIVE DETAIL
NON-WOVEN GEOTEXTILE
FABRIC
COMPACTED AGGREGATE INDOT
NO. 53 BASE COURSE, 6" THICK
PEDESTAL, UPENDER AND LTV CRADLE
AREA PAD DETAIL
A2
TYPICAL SECTION I HWY 486
NOT TO SCALE
A2
TYPICAL SECTION II HWY 486
NOT TO SCALE
COMPACTED FILL/SUBGRADE
12" INDOT NO. 53
BASE, UTF-C-505/A1
2.0 %
MEET EXISTING PER PLANS
MEET EXISTING PER PLANS
25'
COMPACTED FILL/SUBGRADE
12" INDOT NO. 53
BASE, UTF-C-505/A1
2.0 %
MEET EXISTING PER PLANS
MEET EXISTING PER PLANS
25'
2.0 %
6"
6"
COMPACTED
SUBGRADE
COMPACTED AGGREGATE
INDOT NO. 53 BASE
FINISHED GRADE
3/4" R
1-1/2" RADIUS
PAVEMENT SURFACE
(SEE PAVEMENT DETAIL)
(3) #3 BAR (CONT.)
#3 BAR - 18" O.C.
12"
3" (TYP.)
12" CONC. GUTTER
1/4" TO 1/2"
TACK COAT
C3
CONCRETE CURB & GUTTER DETAIL
NOT TO SCALE
2" ABOVE ADJACENT SURFACE
(VARIES DEPENDING
UPON SLOPE
OF ADJACENT SURFACE)
11 - # 6 EACH WAY AT EQUAL
SPACES (TOP & BOTTOM)
3 - # 6 AT EQUAL
SPACES (EACH FACE)
3'-0" X 3'-0" X 3/4" THICK EMBEDDED PLATE
SET TOP OF CONCRETE
SURFACE LEVEL (EACH WAY)
NOTES:
1. SEE DWG. UTF-C-003 FOR ADDITIONAL CONCRETE, REINFORCEMENT, EMBEDDED PLATE & HEADED CONCRETE ANCHOR REQUIREMENTS.
2. STUB CONDUITS 6" ABOVE GRADE W/ SCREW CAP.
3. COIL 11' OF GROUND WIRE ABOVE GRADE.
4. CONDUITS, GROUND AND ASSOCIATED CONCRETE PAD NOT REQUIRED AT THE 1 EMBED IMMEDIATELY ADJACENT TO THE EAST END OF
THE LAUNCH PIT.
℄ EMBEDDED PLATE
D1
DEPRESSED CURB DETAIL
NOT TO SCALE
SEE CONCRETE
CURB & GUTTER
DETAIL
PAVEMENT
GRADE
EXPANSION
JOINT (TYP.)
FINISHED
GRADE
12' (PER PLAN)
6'
6" CURB
FACE
4"
NOTE:
1. AGGREGATE WITHIN SUBSTATION FENCED ENCLOSURE MUST BE 3000
OHM-METERS MINIMUM. PROVIDE TEST DOCUMENTATION.
12"12"
C
L R
C
L R
# 5 AT 1'-3" EACH WAY FOR SLAB-ON-GROUND
4 - #5 CONTINUOUS
BARS AT EQUAL
SPACING
# 5 AT 12"
# 5 AT 12"
EACH WAY
(T & B)
# 5 AT 12"
EACH WAY
(T & B)
3"
2"
3'-0"
CONC PAD UTF-C-503/A1
6" 4"
4"
4"
(2) 2" POWER
CONDUITS
(2) 2" DATA
CONDUITS
GROUND/
1" CONDUIT
A4
CONCRETE CHANNELFOR FUTURE RAIL EMBEDMENT
NOT TO SCALE
B4
CDAS CAMERA POLE CONCRETE PAD W/ STEEL EMBED
NOT TO SCALE
6"
2'-10"
" Ø "VENT"
HOLE
C
L R
2" CLR
(TYP)
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-506
12810636
AS NOTED
KM MD JK
4.00
2.50 3.062 1.278 0.669 0.760 0.228 0.313 0.352
1.968 3.500 1.336 0.834 1.187 0.707 0.664
A
XX
Y
Y
C
D
B
N.T.S.
A
XX
Y
Y
1"
C
D
B
"A" "B" "C" "D"
DIMENSIONS (IN)
AREA
IN.
I(IN. )S(IN. )I(IN. ) S(IN. )
4 3 4
Y-Y AXIS
1.516 0.539
0.611 1.161
4.00
2.50 3.125 1.250 0.625 0.748 0.233 0.289 0.353
1.845 3.500 1.625 0.718 1.190 0.560 0.690
"A" "B" "C" "D"
DIMENSIONS (IN)
AREA
IN. I(IN. )S(IN. )I(IN. ) S(IN. )
4 3 4
Y-Y AXIS
1.549 0.551
0.500 1.190
12"
3"
6"
0.120" NOM.
(11 GAUGE)
1"
14"
7"
0.120" NOM.
(11 GAUGE)
I A
H
O L
C
T
O
C
TYPE 1 STEEL U-POST PROPERTIES
TYPE 2 STEEL U-POST PROPERTIES
TYPE 1 STEEL
U-POST
TYPE 2 STEEL
U-POST
V E
R T
I C
S
T
L
E N
G
I A
H
O L
C
T
O
C
TOP POST
U-POST
TYPE 1
SOIL ANCHOR PLATE
TYPE 2
SOIL ANCHOR PLATE
TYPE 1
ANCHOR POST
ASSEMBLY
TYPE 2
ANCHOR POST
ASSEMBLY
I A
H
O L
C
T
O
C
WEIGHT
LBS. / FT.
X-X AXIS
WEIGHT
LBS. / FT.
X-X AXIS
8TH HOLE FROM THE TOP
TYPE 1 SOIL ANCHOR PLATE
TYPE 1 STEEL U-POST
13TH HOLE FROM THE TOP
TYPE 2 SOIL ANCHOR PLATE
TYPE 2 STEEL U-POST
STEEL U-POST SIGN
SUPPORTS
7/16" DIA. HOLES
7/16" DIA.
HOLES
NOTES:
1. SURFACES ARE PRIMED WITH RUST & CORROSION RESISTANT, ZINC RICH
PRIMER W/5,000 HOUR SALT SPRAY PERFORMANCE.
2. WHERE ADJACENT TO ROLL-UP DOORS, ALIGN CENTER OF BOLLARD WITH
DOOR JAMB AND OFFSET 12" FROM BUILDING.
6"
3/4" THICK STEEL PLATE
W/4 1/2" DIA. X 6" LONG
ANCHOR BOLTS
CONCRETE
PAD
18"
STEEL SAFETY YELLOW
WALL THICKNESS MIN 0.432"
18"
YELLOW HDPE
BOLLARD COVER
CONCRETE TO BE RAISED FOR
PROPER WATER RUN OFF
6" STEEL PIPE FILLED w/ CONC &
EMBEDDED IN CONC BASE. PAINT
HIGH VISIBILITY YELLOW.
PITCH AWAY FROM BOLLARD
PROPOSED SURFACE PER PLAN
PROVIDE EXPANSION JOINT MATERIAL
BETWEEN CONCRETE FOUNDATION AND
OTHER CONCRETE SURFACES
4,000 PSI AIR ENTRAINED CONCRETE
6x6x6 WELDED WIRE FABRIC (WWF)
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT SPECIFICATION
NOTES:
1. BOLLARDS REQUIRED AS DEPICTED ON SITE PLAN DRAWINGS.
2. WHERE ADJACENT TO ROLL-UP DOORS, ALIGN CENTER WITH DOOR JAMB.
3. WHERE ADJACENT TO CONCRETE PADS FOR HVAC UNITS KEEP 3' CLEAR.
4" AZURE BLUE
PAINTED STRIPING
(TYP.) ACCESSIBLE
SYMBOL (54"W x 60"H)
4" AZURE BLUE
PAINTED
STRIPING @ 12"
O.C. (TYP.)
8'-0" 8'-0"
20'
5'-4"
4'-4 1/2"
4" AZURE BLUE
PAINTED
STRIPING (TYP.)
1'-2"
PARKING
RESERVED
ACCESSIBLE
VAN
1'-0"
1/4" x 1/2" LG. PIN HD. BOLTS
WITH NUTS & LOCK WASHERS
AZURE BLUE LETTERS
WHITE BACKGROUND
AZURE BLUE
R7-8
R7-8P
FIN. GRADE
A
B O
V E
G R
O U
N D
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT SPECIFICATION
12"
NOTE:
1. SEE STEEL POST DETAIL.
2. SET BACK 3' FROM EOP.
B2
ULTF BOUNDARY MARKER SIGN DETAIL
NOT TO SCALE
A3
BOLLARD, TYPE 2, CONCRETE EMBEDDED
C3
ACCESSIBLE PARKING SIGN
DETAILS (R7-8, R7-8P)
B3
ACCESSIBLE STALL MARKING
NOT TO SCALE
B4
STEEL POSTS, POST CLIPS, SPACING, ETC.
NOT TO SCALE
CURB
LINE/EOP
A2
BOLLARD, TYPE 1, SURFACE MOUNTED
NOT TO SCALE
#4 BARS @ 12" O.C.
EACH WAY (TYP.)
4,000 PSI CONCRETE
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT SPECIFICATION
CUT REINFORCEMENT
AT JOINT AS SHOWN
BACKER ROD
TWO COMPONENT POLYURETHANE
BASED ELASTOMERIC SEALANT
PROVIDE 1/2" DIA. SMOOTH BARS
(DOWELS) X 1'-6" LG. GREASE &
WRAP ONE END@ 12" O.C.
PROVIDE BUTYL ROD &
FILL WITH SEALANT
PROVIDE SMOOTH BARS
(DOWELS) GREASE & WRAP
ONE END @ 12" O.C.
2"
2"
3/16" SAW CUT
2"
1/2" EXPANSION JOINT
CONDUIT
SEE DUCT BANK SECTIONS
3"
3" 3"
3"
C1
DUCT BANK CONCRETE ENCASEMENT DETAIL
NOT TO SCALE
B1
TYPICAL CONTRACTION JOINT DETAIL
NOT TO SCALE
A1
TYPICAL ISOLATION JOINT DETAIL
NOT TO SCALE
NOTES:
1. PLACE SIGNS AT ALL CORNERS & EVERY 100' ALONG
FENCE LINE.
2. POST SIGNS ON CHAIN LINK FENCE USING THE GALVANIZED STEEL BRACKET
SIGN HOLDER. EACH BRACKET INCLUDES 3/4-INCH LONG STAINLESS STEEL
BOLT AND NYLON WASHER FOR USE WITH 3/8-INCH MOUNTING HOLES.
BOUNDARY
1'-6"
3" BLACK
LETTERS
WHITE
BACKGROUND
ULTF
MARKER
RESTRICTED
WARNING
AREA
KEEP OUT
AUTHORIZED
2'-0"
PERSONNEL
ONLY
3" BLACK
LETTERS
6"
GRADE
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT SPECIFICATION
ACCESSIBLE
PARKING
SIGN SEE DETAIL
UTF-C-506/C3
A4
NOT TO SCALE
2.5'2.5'
NOTES:
1. BOLLARDS TO BE INSTALLED WHERE FOUNDATIONS ARE ADJACENT
TO VEHICLE TRAFFIC AREAS AND/OR AS SHOWN ON PLANS
BOLLARD LAYOUT AT LIGHT
POLE FOUNDATIONS
BOLLARD TYPE 2
SEE DETAIL
UTF-C-506/A3
LIGHT POLE
FOUNDATION
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-507
12810637
AS NOTED
KM MD JK
NOTES:
1. CONCRETE MUST BE 4,000 PSI.
2. BUTT DIAMETER OF FLAG POLE SHALL BE 3" WHILE TOP DIAMETER IS 1 7/8".
C
L R
PLAN VIEW
0'-4"
LAP (MIN.)
ANCHOR BOLTS AND BASE PLATE AS
REQUIRED BY POLE MANUFACTURER
3/4" NON-SHRINK GROUT PACKED UNDER
POLE BASE TO ENSURE FULL CONTACT WITH
FOOTING AND PREVENT LOOSENING OF LEVELING
NUT. SLOPE TOP TO OUTSIDE EDGE OF FOOTING.
PROVIDE 3/8" WIDE x 3/8" DEEP CHANNEL
THROUGH GROUT FOR DRAINAGE FROM POLE
INTERIOR.
3~#3 TIES @ 3" O.C.
AT ANCHOR BOLTS
SLOPE AWAY
FROM BASE PLATE
#3 TIES @ 12" O.C. MAX.
36" DIAMETER CAST-IN
PLACE CONCRETE
FOUNDATION
#3 TIES
W/LAPPING
7~#8 VERTICALS
7~#8
VERTICALS
LEVELING NUT
AND WASHER
POLE BASE COVER
15'-0" HIGH FLAG POLE
A
L U
M I N
M
L
E
E
X P
O S
I G
H T
ANODIZED SPUN
ALUMINUM BALL, FLUSH SEAM
SINGLE SHEAVE TRUCK
CAST ALUMINUM REVOLVING
NON-FOULING TYPE
ONE (1) SET
OF HALYARDS
9" CAST ALUMINUM CLEAT WITH
1/4"-20NC FLAT HEAD STAINLESS
STEEL SELF DRILLING SCREWS
TWO (2) SNAP HOOKS,
WITH NEOPRENE COVERS
7' TAPERED ALUMINUM
POLE (15' EXPOSED)
FINISHED GRADE
A4
15' TAPERED ALUMINUM FLAG POLE
NOT TO SCALE
1.5' MIN.
EMBEDMENT
W A
I G
V
R
I E
S
M
I N
M
A X
24" DRAINAGE GRAVEL
NOTES:
1. RETAIN/COORDINATE W/ A MODULAR BLOCK MANUFACTURER AND PROVIDE DESIGN DRAWINGS AND CALCULATIONS, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF INDIANA, FOR THE WALL DESIGN AND
CONSTRUCTION. THE SITE CONTRACTOR MUST OBTAIN ADDITIONAL GEOTECHNICAL INFORMATION AS REQUIRED FOR
THE FINAL WALL DESIGN. SOIL BEARING CAPACITIES MUST NOT BE ASSUMED FOR WALLS GREATER THAN 4' IN HEIGHT.
COMPLETE WALL DESIGN MUST BE INCLUDED WITHIN THE BASE BID.
2. DECORATIVE FACE MUST BE GRAY COBBLE STONE.
3. MODULAR BLOCK DIMENSIONS AND WEIGHT WILL VARY WITH FINAL DESIGN. FULL BLOCK MUST WEIGH BETWEEN 1,200
LBS - 3,500 LBS.
C2
MECHANICALLY STABILIZED EARTH WALL
NOT TO SCALE
COMPACTED
AGGREGATE INDOT NO.
53 BASE 6" THICK
EXISTING UNDISTURBED SOIL /
COMPACTED STRUCTURAL FILL
12"
STRUCTURAL GEOGRID
REINFORCEMENT
AS REQUIRED
RETAINED SOIL
REINFORCED BACKFILL
DECORATIVE
FACE MODULAR
BLOCK WALL
4" PERF. PVC DISCHARGE
TO DAYLIGHT
FILTER FABRIC
2" PVC
WEEP HOLE
20' +/- OC
A2
FORCE MAIN DUAL CLEANOUT DETAIL
NOT TO SCALE
48" MIN.
NOTES:
1. ALL METALLIC FITTINGS / PIPING WITHIN MANHOLE MUST BE PAINTED, UNLESS
FACTORY COATED.
2. PROVIDE VENT PIPE FROM MANHOLE TO GRADE (SEE VENT DETAIL).
3. SANITARY SEWER PIPE TO MANHOLE SEAL MUST BE PURSUANT TO ASTM-923.
4. PROVIDE MANHOLE STEPS PURSUANT TO SPECIFICATION SECTION 33 30 00.
3" X 3" WYE
(TYP. OF 2)
STAINLESS STEEL PIPE
SUPPORT
(TYP. OF 2)
3" HDPE SANITARY FORCE MAIN
PLUG VALVE, FULL
PORT
(TYP. OF 2)
RESTRAINED FLANGE
ADAPTER (TYP.)
" PLUG VALVE WITH
THREADED FITTING
AND CAP SUITABLE OR
HOSE CONNECTION
(TYP. OF 2)
VALVE BOX,
SEE DETAIL
(TYP. OF 2)
POLYPROPYLENE
STEPS, 12" O.C.
FRAME AND COVER,
SEE DETAIL
FINISHED GRADE
(TYP.)
PRECAST
MANHOLE
3" BLIND FLANGE (FLG.)
TAPPED FOR PLUG VALVE
(TYP. OF 2)
1' X 1' X 6" SUMP
CLASS C CAST-IN-PLACE
CONCRETE BASE
6" MIN.
#4 @ 12" O.C. E.W.
8" MIN.
12" MIN.
24" MIN.
6" MIN.
M
I N
48" MIN.
12" (TYP.)
10" REINFORCED CONCRETE
LID TO SUPPORT H-25
VEHICULAR TRAFFIC
12"
DECORATIVE STONE
.5%
BACK FACE OF
RETAINING WALL
℄ UTILITY
TRENCH TYPE 3
SEE UTF-C-503/C4
℄ UTILITY
TRENCH TYPE 3
SEE UTF-C-503/C4
APPROX. SURFACE
OF ROCK
INV. 713.23
CONCRETE PIER
CONCRETE
COLUMN
INV. 713.37
4" PVC
EL. 719.0
A1
TRENCH DETAIL AT CROSSFLOW PIT WALL
NOT TO SCALE
SECTION A-A
.5%
10'-0"
INV. 713.23
4" PVC
℄ 2'-6" X 3'-0" BEAM
10'-0"
10'-0"
4" PVC
INV. 713.37
.5%
3'-0"
3'-0"
3'-0" 8"
8"
A U
T F
C
U T
F C
V A
R I E
S
℄ 2'-6" X 3'-0" BEAM
KEY MAP
SECTION A-A
SECTION B-B
SECTION C-C
SECTION B-B
SECTION C-C
SEE UTF-C-508/A4
FOR FRAME AND
COVER
INSTALLATION
REQUIREMENTS
SEE UTF-C-508/A4
FOR FRAME AND
COVER
INSTALLATION
REQUIREMENTS
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-508
12810638
AS NOTED
KM MD JK
12"
V A
R I A
B L
E
P
I
D
V
A
R
I
A
B
L
E
COMPACTED AGGREGATE, INDOT NO. 53, BASE
EXISTING MUST BE
SAWCUT FULL DEPTH
(BOTH SIDES)
EXISTING GROUND
PAVED
AREA
UNPAVED AREA/COMPACTED EARTH
TRAVEL AREA
12"
INITIAL BACKFILL
MATERIAL
COMPACTED FILL TO 95%
MODIFIED PROCTOR
DENSITY ASTM D-1557
EXISTING
PAVEMENT
PAVED
AREA
NON-PAVED AREA
18"
(WATER SYSTEM, SANITARY SEWER SYSTEM,
ELECTRIC/COMMUNICATION SYSTEMS)
NOTES:
1. PROVIDE WARNING TAPE AND DETECTION WIRE PER PROJECT SPECIFICATIONS.
2. SEE CONCRETE ENCASEMENT DETAIL FOR ELECTRIC/COMMUNICATION CONDUIT WITHIN
THIS TRENCH.
D
PAVED AREAS
SEE BITUMINOUS PAVEMENT
DETAIL REF. LTF-C-508/2
NON-PAVED AREAS
COMPACT TO 95% MODIFIED
PROCTOR DENSITY
(ASTM D-1557)
4" PLUS 1/2 PIPE DIA. MIN.
INITIAL BACKFILL MATERIAL
UNDISTURBED EARTH
(NOTE 2)
A P
P R
O V
X C
A V
A T
M
T
E R
I A
L S
E M
B E
D M
E N
T
Z O
N E
N
O T
E
B A
C K
F I L
L
Z
O N
E
FINISHED GRADE
PIPE
D.D.
NOTES:
1. PLACE EMBEDMENT ZONE BACKFILL BY HAND IN 6-INCH LIFTS ON BOTH
SIDES OF PIPE. COMPACT TO 95% MAX. DRY DENSITY IN ACCORDANCE
WITH ASTM D-1557.
2. IF UNSUITABLE SOIL MATERIALS ARE ENCOUNTERED, REMOVE AND REPLACE WITH
ADDITIONAL BEDDING AS DIRECTED BY CONTRACTING OFFICER.
MIN. MIN.
12" 12"
COMPACTED AGGREGATE, INDOT
NO. 53, BASE
SAWCUT 18" (TYP.)
FOR PAVEMENT
SWALE NO. 1
A B
3' 1'
'B'
UNDISTURBED
SOIL/COMPACTED FILL PER
PROJECT SPECIFICATIONS
B - MIN. DEPTH
MAX. SLOPE
FINISHED GRADE
'A'
NOTE:
1. SEE DRAINAGE & UTILITY PLANS FOR SWALE SIZE & LOCATION
G
R
O
U
R
F
A
C
E
B
U
I L
D
I
G
C
A
D
E
DOWNSPOUT (ALSO
LEADER OR CONDUCTOR)
WALL BRACKET
ELBOW
CONCRETE
SPLASH
BLOCK
3"
VEHICLE TRAVEL
AREA
L2
W1
L1
W2
D d50=24"
48" THICK W/ FILTER
FABRIC
OUTLET
SH #1 (HW #1)
W1 W2 D TH d50
(ft.) (ft.) (ft.) (ft.) (In.) (In.) (In.)
FLOW
HEAD WALL REF.
UTF-C-512
PLAN
3:1 3:1
SEE SITE PLAN FOR PIPE
ORIENTATION AND SIZE
SECTION B-B
L1 L2 PIPE SIZE
(In.)
TH
FILTER FABRIC
SH #2 (HW #2)
2.5 15
30"
9" 9"
NOTES:
1. SEWER CLEANOUTS REQUIRED AT ALL BENDS, CHANGES
IN SLOPE AND AT BUILDING EXIT UNLESS A MANHOLE IS
PROPOSED.
2. FRAME AND COVER MUST BE NEENAH FOUNDRY PATTERN
NO. R 1792 CL TYPICAL FOR ALL CLEANOUTS, VALVE BOXES
APPLICATIONS.
BRASS PLUG
GRADE
SEE PLAN FOR
MATERIAL
COMPACTED
AGGREGATE, INDOT
NO. 53, BASE
4000 PSI CONCRETE ON
COMPACTED SUBGRADE
COMPACTED SUBGRADE
PVC PIPE
TEE ELBOW
12"
CAST IRON COVER & CIRCULAR FRAME
SEE BITUMINOUS PAVEMENT DETAIL
3.75
11.25
C1
TYPICAL TRENCH, STORM SEWER SYSTEM
NOT TO SCALE
A1
UTILITY TRENCH AND BEDDING DETAIL
NOT TO SCALE
B3
SWALE DETAIL
NOT TO SCALE
C4
PREFORMED SCOUR HOLE
NOT TO SCALE
B4
ROOF DRAIN AND SPLASH BLOCK DETAIL
NOT TO SCALE
A4
SEWER CLEANOUT DETAIL
NOT TO SCALE
TOP SOIL, FERTILIZER
AND SEED / PER PLAN
TOP SOIL, FERTILIZER
AND SEED / PER PLAN
SH #3 (HW #3)
SH #4 (HW #6)
4 246 10 12 12 12 6
2.5 153.75 10 11.25 15 12 6
CASTING (TYP)
TO SUPPORT
BRICK SHIM
A
"TERMINAL" INLET DETAIL
SECTION B-B
1'-10"
5"
6"
SECTION A-A
B
A
VARIES
8"
1'-10"
"THROUGH" INLET DETAIL
6" PRECAST CONCRETE
B
COMPACTED AGGREGATE,
INDOT NO. 53, BASE
NOTES:
1.
2.
3.
5.
LADDER RUNGS, 12" O.C. AT OVER 4 FOOT DEPTHS.
6.
7.
PRECAST CONCRETE MUST BE 4000 PSI.
THE TOP OF GRATE TO INVERT.
INLET MUST NOT EXCEED A DEPTH OF 8'-0" MEASURED FROM
INLET FRAME AND GRATES MUST BE NEENAH FOUNDRY PATTERN
BOTTOMS MUST BE DISHED AND SLOPED TOWARDS THE OUTLET
PROVIDE 7/8" DIA. X 7" X 12" STEEL REINFORCED POLYPROPYLENE
NO. R 3430, GRATE TYPE C OR APPROVED EQUAL.
PIPE AT A RATE OF 2 INCHES PER FOOT.
INVERTS MUST BE ELIMINATED IN BOTTOM OF TERMINAL INLETS.
INLET MUST BE PRECAST CONCRETE.
MANUFACTURER FOR H-25 LOADING IN & WITHIN 20' OF PAVED AREAS.
PRECAST STRUCTURE REINFORCING MUST BE DESIGNED PER
8.
PER MANUFACTURER'S SPECIFICATION.
TWO COATS OF BITUMASTIC WATER PROOFING MUST BE APPLIED
4.
A3
TYPE "A" INLET
NOT TO SCALE
B B
SWALE NO. 2 3' 1'
SWALE NO. 3 3' 1'
SLOPE
4.7%
4.7%
1.0%
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-509
12810639
AS NOTED
JK MD KM
24" (MIN.) THICK
BIORETENTION
SOIL MEDIA
EXISTING SOIL SUBGRADE,
TILLED OR "RIPPED" 12"
DEEP BEFORE BACKFILLING
4" Ø SCHEDULE 40 PVC OR SDR 35
PERFORATED PIPE, 3/8" Ø HOLES, TWO
SIDES, FACING DOWN, 2" OFF BOTTOM
FILTER FABRIC
(SIDES ONLY)
3" THICK MULCH
SLOPE VARIES, SEE
GRADING PLAN (TYP.)
6" THICK SAND (ASTM C-33
FINE AGGREGATE)
6" THICK 3/8" Ø GRAVEL
(ASTM C-33 NO. 8)
6" THICK 3/4" Ø GRAVEL
(ASTM C-33 NO. 6 OR 67)
INVERTS (SEE DETAIL A3
ON THIS SHEET)
CLEANOUT/OBSERVATION
WELL
NOTE:
SAND AND GRAVEL MUST BE NATURAL, UNCRUSHED.
SEE LANDSCAPE PLAN FOR VEGETATION IN BIORETENTION BASIN.
THE PLANTING SOIL MUST BE A SANDY LOAM OR LOAMY SAND CONTAINING A MINIMUM OF 60 PERCENT SAND, BY VOLUME. THE CLAY
CONTENT MUST BE LESS THAN 10 PERCENT BY VOLUME. A SATURATED HYDRAULIC CONDUCTIVITY OF AT LEAST 2.0 FEET PER DAY (1.0 INCHES
PER HOUR) IS REQUIRED. THE SOIL MUST BE FREE OF STONES, STUMPS, ROOTS, OR OTHER WOODY MATERIAL OVER 1 INCH IN DIAMETER AND
MUST BE FREE OF BRUSH OR SEEDS FROM NOXIOUS WEEDS, SUCH AS JOHNSON GRASS, MUGWORT, NUTSEDGE AND CANADIAN THISTLE.
PLACEMENT OF THE PLANTING SOIL MUST BE IN LIFTS OF 12 TO 18 INCHES, LOOSELY COMPACTED (RUBBER WHEELED HEAVY EQUIPMENT AND
MECHANICAL TAMPING DEVICES ARE NOT RECOMMENDED FOR COMPACTION). THE PH RANGE MUST BE BETWEEN 5.2 AND 8.0. ORGANIC
MATTER MUST BE BETWEEN 1.5 AND 5%. MAGNESIUM, PHOSPHORUS AND POTASSIUM MUST BE APPLIED AT MINIMUM RATES OF 35, 75 AND 85
LBS. PER ACRE.
THE MULCH LAYER MUST BE STANDARD LANDSCAPE STYLE, SINGLE OR DOUBLE SHREDDED HARDWOOD MULCH. THE MULCH LAYER MUST BE
FREE OF OTHER MATERIALS, SUCH AS WEED SEEDS, SOIL, ROOTS, ETC.
WIDTH VARIES, SEE PLAN VIEW
OUTLET CONTROL
STRUCTURE
THREADED PLUG
B1 BIORETENTION BASIN - TYPICAL SECTION
NOT TO SCALE
A3 OUTLET CONTROL STRUCTURE
NOT TO SCALE
COMPACTED SUBGRADE
P
R
O
G
A
D
E
TOP OF BERM EL. G
TOP OF BOX TRASH RACK
OVERFLOW WEIR
FOOTING
PROP. CONC.
PLAN VIEW
A
A
FRONT ELEVATION
H
SIDE ELEVATION
SEE PLAN
INV. A
4'-0"
4'-0"
TRASH RACK ASSEMBLY
ROOF MOUNT
TRASH RACK ASSEMBLY
SIDE MOUNT
ELEV. E
TRASH RACK
ORIFICE
INV. D
OUTFLOW PIPE SIZE
AND ORIENTATION
SEE PLAN
CONTROL STRUCTURE:
INDOT CATCH BASIN - TYPE "A" OR
APPROVED EQUAL
OVERFLOW WEIR
ELEV. E
TOP OF BOX TRASH RACK
CONTROL STRUCTURE:
INDOT CATCH BASIN - TYPE "A" OR
APPROVED EQUAL
THREADED
PLUG
INV. B
INV. C
4"Ø UNDERDRAIN
(SCHEDULE 40 PVC
OR SDR 35)
CLEANOUT/OBSERVATION WELL
BOTTOM OF BIORETENTION BASIN = ELEV. F
BOTTOM OF BIORETENTION BASIN = ELEV. F
ORIFICE IN CONTROL STRUCTURE
(10" OCS A; 6" OCS B)
INV. D
4" UNDERDRAIN
INV. C
4" UNDERDRAIN
INV. B
TRASH RACK ASSEMBLY
STRUCTURE A B C D E F G
OCS A 686.00 686.50 687.75 690.70 (10") 693.25 690.00 695.00
OCS B 708.00 708.50 710.75 712.90 (6") 715.70 712.00 717.00
ELEVATION/DIMENSION TABLE
H
2.55'
2.80'
NOTES:
1. TRASH RACK MUST BE CONSTRUCTED OF GLASS-REINFORCED HDPE AS MANUFACTURED BY
PLASTIC SOLUTIONS INC. OR APPROVED EQUAL.
2. GRID MATERIAL MUST NOT EXCEED 6" ON CENTER.
3. UV PROTECTION MUST MEET OR EXCEED ASTM D 2565-99.
4. LOAD RATING: 2030 LBS./SF
5. ANCHOR BOLTS MUST BE STAINLESS STEEL AND LOCATED PER MANUFACTURER'S
PRE-DRILLED HOLES.
NOTES:
1. PRECAST REINFORCED CONCRETE METER PIT; HS-25 RATED LOADING.
2. FIXED LADDER IN ACCORDANCE WITH OSHA STANDARDS 29 CFR. STEEL REINFORCED
POLYPROPYLENE LADDER RUNGS MUST BE INSTALLED.
3. LOCKABLE ACCESS HATCH W/FLUSH MOUNT LIFT HANDLE.
4. REMOTE METERING DEVICE MUST BE COMPATIBLE WITH EXISTING BASE METERING AND
REPORTING SYSTEM.
5. PROVIDE BACKFLOW PREVENTORS AT ALLBUILDINGS AND TAKEOFF POINTS.
6. PROVIDE SUPPORT VALVES, PIPING, METER AND STRAINER TO VAULT BASE AS REQUIRED.
7. FILL ANNULAR SPACE BETWEEN WALLS AND SLEEVES WITH RICH CEMENT MORTAR AND
ANNULAR SPACE BETWEEN PIPE AND SLEEVE WITH MASTIC.
8. ACCESS HATCH MUST BE PROVIDED IN THE DIMENSIONS INDICATED AND ADHERE TO THE FOLLOWING REQ:
8.1. HATCH MUST BE ALUMINUM DOUBLE LEAF HINGED DOORS REINFORCED TO SUPPORT AAHSTO HS-25
WHEEL LOAD WITH A MAXIMUM DEFLECTION OF 1/150TH OF THE SPAN.
8.2. COVER MUST BE
" ALUMINUM DIAMOND PATTERN.
8.3. FRAME MUST BE
" EXTRUDED ALUMINUM WITH ANCHOR TABS AROUND THE PERIMETER FOR
ANCHORING IN PLACE BY CASTING INTO THE PRECAST VAULT STRUCTURE.
8.4. LIFTING MECHANISMS: MANUFACTURER MUST PROVIDE THE REQUIRED NUMBER AND SIZE OF
COMPRESSION SPRING OPERATORS ENCLOSED IN TELESCOPIC TUBES TO PROVIDE SMOOTH, EASY, AND
CONTROLLED COVER OPERATION THROUGHOUT THE ENTIRE ARC OF OPENING AND TO ACT AS A CHECK
IN RETARDING DOWNWARD MOTION OF THE COVER WHEN CLOSING. SPRINGS AND SPRING TUBES MUST
BE TYPE 316 STAINLESS STEEL.
8.5. A REMOVABLE EXTERIOR TURN/LIFT HANDLE WITH A SPRING LOADED BALL DETENT SHALL BE PROVIDED
TO OPEN THE COVERS AND THE LATCH RELEASE MUST BE PROTECTED BY A FLUSH, GASKETED,
REMOVABLE SCREW PLUG.
8.6. HARDWARE:
8.6.1. HINGES: HEAVY FORGED TYPE 316 STAINLESS STEEL HINGES, EACH HAVING A MINIMUM
" DIA.
TYPE 316 STAINLESS STEEL PIN, MUST BE PROVIDED AND MUST PIVOT SO THE COVER DOES
NOT PROTRUDE INTO THE CHANNEL FRAME.
8.6.2. COVERS MUST BE EQUIPPED WITH A HOLD OPEN ARM THAT AUTOMATICALLY LOCKS THE COVERS
IN THE OPEN POSITION.
8.6.3. A TYPE 316 STAINLESS STEEL SNAP LOCK WITH FIXED HANDLE SHALL BE MOUNTED ON THE
UNDERSIDE OF THE COVER.
8.6.4. HARDWARE MUST BE TYPE 316 STAINLESS STEEL THROUGHOUT.
8.6.5. HARDWARE EXPOSED WHEN COVER IS CLOSED MUST BE TAMPER PROOF.
8.7. FINISHES: FACTORY FINISH MUST BE MILL FINISH ALUMINUM WITH BITUMINOUS COATING APPLIED TO
THE EXTERIOR OF THE FRAME.
PLAN
A
UTF-C-513 UTF-C-513
6" OS&Y FLANGED GATE VALVE
6" COMPOUND METER WITH INTEGRATED REMOTE REGISTER
6" OS&Y FLANGED GATE VALVE
6" DI
6" PLATE-TYPE STRAINER
3'x3' FRAME AND
ACCESS HATCH
HS-25 LOADING
6" DI
6" DI
1 1/2"Ø DIA. STEEL REINFORCED
POLYPROPYLENE LADDER RUNGS @
12" O.C. (TYP.)
PRECAST METER PIT
(10'x4'x6')
WATERPROOF
COMPOUND
(ALL SIDES)
12" COMPACTED
AGGREGATE, NO. 53,
BASE
10'-0"
11'-0"
6" (TYP)
8" DUCTILE IRON PIPE
SLEEVE OR SCH 40
STEEL WALL SLEEVE
(TYP.) SEE NOTE #7
UNDISTURBED
SOIL/COMPACTED
FILL PER
PROJECT
SPECIFICATIONS
12"x12" OPENING
THROUGH FLOOR
SECTION A-A
6" DI
F I
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-510
12810640
AS NOTED
KM MD JK
6" DI
6" GATE VALVE
C.I. VALVE BOX
M
I N
I M
U M
D E
P T
H
V
A R
I E
S
COMPACTED EARTH
TRAVEL AREA
12" TYPICAL
(VARIABLE)
36" MIN.
84" MAX.
CONNECTIONS AS SPECIFIED (1)
4-1/2"
(2) 2-1/2" TYP.
M
I N
M A
X
POROUS FILL
AROUND BARREL
POURED CONCRETE THRUST
BLOCK PER THRUST BLOCK
DETAIL
WATER MAIN
BEARING ON
UNDISTURBED
GROUND
POURED CONCRETE
THRUST BLOCK PER
THRUST BLOCK
DETAIL
TIE RODS (3/4" MIN.)
6" GRAVEL BEDDING
UNDER ALL VALVES
AND FITTINGS
BEARING ON
UNDISTURBED GROUND
1 CUBIC FOOT GRAVEL OR
BROKEN STONE DRAIN
CONSTRUCTION NOTES:
1. USE 2500 PSI CONCRETE FOR THRUST BLOCKS.
2. SIZE AND BEARING AREA FOR THRUST BLOCKS PER THRUST BLOCK DETAIL.
3. FINISH PAINTING MUST BE RED OR AS DIRECTED BY THE CONTRACTING OFFICER. STENCIL
ALUMINUM HYDRANT NUMBER TAG AND MAIN SIZE ON THE HYDRANT BARREL USING BLACK STENCIL
PAINT. HYDRANT NUMBER MUST BE PROVIDED BY THE CONTRACTING OFFICER.
4. SPECIAL HYDRANT ARRANGEMENTS OR SETTINGS MUST BE DETAILED BY CONTRACTOR SUBJECT TO
CONTRACTING OFFICER'S APPROVAL.
5. USE MECHANICAL JOINT CONNECTIONS AND FITTINGS.
6. PROVIDE BOLLARDS WHERE SHOWN ON PLANS AND AS PER DETAIL.
7. PROVIDE NFPA FLOW COLOR CODED RINGS.
EDGE OF
COMPACTED
EARTH TRAVEL
AREA
CI LID MARKED
"WATER"
HYDRANT TO HAVE BREAK
SECTION 4" ABOVE GRADE
DRAIN PORTS MUST BE FREE OF
CONCRETE OR OTHER
PERMANENT OBSTRUCTIONS
T
Y
P
EDGE OF PAVEMENT
NOTES:
1. USE WHERE SHOWN ON PLANS.
2. REFER TO FIRE HYDRANT DETAIL FOR HYDRANT INSTALLATION AND CONNECTION TO
FIRE MAIN.
3. REFER TO BOLLARD TYPE 2 DETAIL UTF-C-506/A3 FOR CONSTRUCTION.
3'-0"
8"
NOTES:
1. THRUST BLOCK BUILT AGAINST UNDISTURBED SOIL WITH ADEQUATE BACKING TO PREVENT MOVEMENT OF FITTING.
2. BEARING TABLE BASED ON 150 PSI OPERATING PRESSURE, 2500 PSF SOIL BEARING CAPACITY, AND A FACTOR OF SAFETY OF 1.5.
3. PIPE JOINTS AND BOLTS MUST BE ACCESSIBLE.
4. FELT WRAP AND TAPE FITTING FASTENER AREAS PRIOR TO THE CONCRETE THRUST BLOCK POUR TO ALLOW
FUTURE ACCESS TO THE FASTENERS AT THE JOINTS.
5. FOR THRUST BLOCKING ON VALVE, SEE VALVE DETAIL.
6. THRUST BLOCKING DETAILS ARE SHOWN FOR TYPICAL INSTALLATIONS. IN SOME CASES ADDITIONAL RESTRAINT MAY BE REQUIRED. FOR
UNSTABLE SOIL CONDITIONS, SUBMIT RFI TO CONTRACTING OFFICER FOR THRUST BLOCK DIMENSIONS.
7. USE 2500 PSI PORTLAND CEMENT CONCRETE FOR THRUST BLOCKS.
8. WHERE PIPES ARE INSTALLED PARALLEL TO EACH OTHER, USE RESTRAINED JOINTS WHERE THRUST BLOCKS CANNOT BE USED.
B
BA
dxe
C B
6" 5"
ACB
6" 7" e
A
B
8" 1'-3"
A
A d
A
B
8" 2'-0" d
B
1'-6"
C
R E
D U
C E
R S
AC
B
6"
12"
ACB
6"
Ad
2"-2.5"
B
E N
D S
8"
A
2'-6" d
B
B
E N
D S
8"
B
A
1'-9" d d
B
2'-6"
C
B
6"
B
A C d
1'-9" 1'-9"
T E
P
S
B E
N D
S
MINIMUM SIZE OF 2500 PSI CONCRETE THRUST BLOCKS FOR WATER MAINS
CB
5'-6" 2'-3"
A
5'-6"
V
E R
T I C
A L
B
E N
D
10" 1'-9"
10" 2'-6" 1'-9"10" 3'-6"10"
2'-6" 3'-6"8" 2'-3"
2'-6"
1'-3" 1'-3"
8"x6"
C
A
B
C
V
E R
T I C
A L
B
E N
D
9"8" 10" 7"
5'-6" 3'-7"
4'-9"
#4
REIN.
BAR
12" 3'-0"12" 4'-0"12"
2'-9" 4'-0"
2'-9" 3'-0"
12" 2'-0"
2'-3"10" d
2"-2.5"
6"
8"
10"
A1
WATER METER VAULT DETAIL
NOT TO SCALE
A2
FIRE HYDRANT BOLLARD LOCATION DETAIL
NOT TO SCALE
A5
FIRE HYDRANT
NOT TO SCALE
B3
THRUST BLOCKING
W W W
W
S A
N
S
A
N
SAN SAN SAN
W W
SAN SAN
S
HPA
H
P
A
H
P
A
E E
E E
E E
E E E E E E E
S
A
N
S
A
N
S
A
N
S
A
N
A A
A
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
C
C
C
C
C
C
C
C
A A A A A A A A A
W
E E
E E
E
E E E E E
E E E
C
C
HPAHPAHPAHPAHPAHPAHPA
E E
E
E
H P
A H
P A
H P
A H
P A
H P
A H
P A
E
S
P
F I
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-511
12810641
AS NOTED
KM MD JK
A
UTF-C-511 UTF-C-511
SECTION A-A
2'-0"
8" THICK 4000 PSI CONCRETE PAD
TOP FLUSH WITH FINISH GRADE
TROWEL EDGE
EXPANSION JOINT
FILLER MATERIAL
2'-0"
VALVE BOX
4"
6"x6" W2.9xW2.9
WELDED WIRE FABRIC
COMPACTED AGGREGATE,
INDOT NO. 53, BASE
SHUT
1 1/4" SQ.
BODY
6" DIAMETER
36"
4'
MINIMUM
5 1/8"
12" DIAMETER
STANDPIPE
(PAINTED BLACK)
STANDPIPE
(PAINTED RED)
STANDPIPE GROUND LINE
MARK
GROUND LINE OR
FINISHED GRADE
PADLOCK
DEPTH OF COVER
4'-0" MINIMUM
2'-0"
SQUARE
2' X 2' X 8" THICK
CONCRETE PAD
SEE VALVE BOX PAD
DETAIL
COMPACTED AGGREGATE,
INDOT NO. 53, BASE
WATER MAIN
COMPACTED AGGREGATE,
INDOT NO. 53, BASE
TOP OF WATER MAIN
FINISHED GRADE
VALVE BOX WITH COVER
(TO BE MARKED "WATER")
SET TOP FLUSH W/ GRADE SEE
VALVE BOX PAD DETAIL
12"
NOTES:
1. CONDUCT INSTALLATION OF TAPPING SLEEVE AND VALVE UNDER
"WET" CONDITIONS. MAINTAIN EXISTING MAINS IN SERVICE AT ALL TIMES
DURING TAPPING OR INSERTION.
2. CONCRETE THRUST BLOCK UNDER TAPPING VALVE MUST HAVE THE
SAME SOIL BEARING AREA AS A 45° ELBOW.
10" DIP WATER PIPE OR
8" PVC SANITARY
FORCE MAIN
PLAN
ELEVATION
MECHANICAL JOINT
TAPPING VALVE
THRUST BLOCK POURED
AGAINST UNDISTURBED
SOIL
MECHANICAL JOINT
TAPPING SLEEVE
THRUST BLOCK POURED
AGAINST UNDISTURBED SOIL
#4 REIN. BAR
MECHANICAL JOINT
TAPPING VALVE
NOTES:
1. REFER TO FIRE HYDRANT BOLLARD LOCATION DETAIL UTF-C-510/A2 FOR
BOLLARD SPACING FOR POST INDICATOR VALVE.
2. BOLLARDS SHALL BE TYPE 2 REFER TO DETAIL UTF-C-510/A2 AND
UTF-C-506/A3
UNDISTURBED SOIL/COMPACTED
FILL PER PROJECT
SPECIFICATIONS
UNDISTURBED SOIL/COMPACTED FILL PER
PROJECT SPECIFICATIONS
A2
VALVE BOX DETAIL
NOT TO SCALE
C3
VALVE BOX PAD DETAIL
NOT TO SCALE
C4
TAPPING SLEEVE AND VALVE DETAIL
NOT TO SCALE
A4
POST INDICATOR VALVE
NOT TO SCALE
SEE VALVE
BOX DETAIL
GATE OR BUTTERFLY
VALVE
NEW DUCTILE
IRON PIPE (TYP)
MECHANICAL JOINT
WITH MEGA-LUG
RETAINER GLANDS
VALVE BOX
M
I N
UNDISTURBED SOIL
A5
WATER VALVE INSTALLATION
NOT TO SCALE
NOTES:
1. FOR MAINS LARGER THAN 6", PROVIDE THRUST BLOCK UNDER
VALVE BODY (3 CU. FT. MINIMUM OR SOLID CONCRETE BLOCK)
8" DIP WATER PIPE
OR 3" HDPE SANITARY
FORCE MAIN
FIRE MAIN
NOTES:
1. STANCOR SE50 SUMP PUMP (0.5hp) PACKAGE OR EQUAL WITH
CHECK VALVE, ON-OFF FLOAT SWITCH, HIGH LEVEL FLOAT
SWITCH, OIL MINDER PROBE AND ASSOCIATED CONTROL SYSTEM.
INSTALL PER MANUFACTURER INSTRUCTIONS.
2. 20" X 20" X 8" MIN NEMA 3R ENCLOSURE TO HOUSE OIL MINDER
CONTROL SYSTEM. PROVIDE UL LISTED AND LABELED CONTROL
CABINET. PROVIDE CONTROLS SO OIL WILL NOT PUMP ON GRADE.
COORDINATE WITH OWNER REMOTE MONITORING LOCATION TO
RECEIVE OIL AND HIGH LEVEL ALARMS
3. DISCONNECT SWITCH 20/2/NF IN NEMA 3R ENCLOSURE.
4. (2) 1" PVC CONDUIT FOR PUMP POWER AND CONTROL CABLES.
PROVIDE LONG RADIUS BENDS TO ALLOW INSTALLATION OF
CABLES WITH PRE-INSTALLED CONNECTORS. SEAL END OF
CONDUIT AT CONTROL CABINET.
5. 1
" PVC SUMP PUMP DISCHARGE PIPING.
6. 2" CHECK VALVE SUPPLIED WITH SUMP PUMP. MOUNT VALVES IN
ACCESSIBLE LOCATION ABOVE PIT.
7. "HIGH LEVEL" FLOAT SWITCH. LOCATE PER MANUFACTURERS
INSTRUCTIONS. PROVIDE AUDIBLE AND VISUAL ALARMS.
8. "PUMP ON" FLOAT SWITCH. LOCATE PER MANUFACTURERS
INSTRUCTIONS.
9. OIL DETECTION PROBE. LOCATE PER MANUFACTURERS
INSTRUCTIONS. PROVIDE AUDIBLE AND VISUAL ALARMS.
10. MODIFY GRATING AS REQUIRED.
6" COMPACTED AGGREGATE, INDOT NO. 53, BASE
UNDISTURBED SOIL/COMPACTED FILL
PER PROJECT SPECIFICATIONS
8" PVC PIPE GROUTED
THROUGH SUMP PIT
WALL AND TRENCH
DRAIN WALL
DRAINAGE TRENCH
SEE UTF-C-503/C4
INV 702.76 INV 703.10
GR 704.10 GR 704.10
2' X 2' SUMP PIT
SUMP PIT
COVER
INV. 716.14
2" SQUARE
WRENCH-NUT
TURN CLOCKWISE
TO OPEN
VALVE BOX MUST
NOT BEAR DIRECTLY
ON THE VALVE
COMPACTED
AGGREGATE, INDOT
NO. 53, BASE
C1
CROSS FLOW SUMP AND DRAINAGE TRENCH DETAIL
NOT TO SCALE
H
U
B
U
P
R
A I L
I N
G
D
T A
C H
A B
W
T
E R
S E
R V
I C
E
U
T F
C
C
S
E R
V I C
E
A
U
B
U
P
S
A N
I T
A R
Y
S E
R V
I C
E
S
T U
B
U
P
U
B
U
P
NOTES:
1. STUB UP HPA WITH HORIZONTAL GRAYLOC ANSI FLANGE SERIES 2GR 14 CONNECTORS OR
APPROVED EQUAL ON EACH END, 18" ABOVE FINISHED GRADE.
2. HPA PIPE MUST BE 2" SCH XXS ASTM A106, GRADE C.
3. STUB UP 1" BLACK STEEL SERVICE AIR 18" ABOVE FINISHED GRADE WITH HORIZONTAL
LOCK-OUT / TAG-OUT VALVE.
4. STUB UP SANITARY SEWER PIPE 18" ABOVE FINISHED GRADE WITH THREADED CAP.
A1
LAUNCH PIT UTILITY STUB-UP AREA DETAIL
NOT TO SCALE
SEE UTF-C-508/A4 FOR
FRAME AND COVER
INSTALLATION
REQUIREMENTS
H
U
B
M
E
C p w w o r k i n g g b n a d a x e s h p d B
L D
G U
T F
C d
Y O
M
E
U
T F
C
O
T T
E D
T u e s d a y
A p r i l
E
R p a t e l d
D E
P A
R T
M E
T
V
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DES DRW CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
P-
UN
DE
RW
AT
ER
L
AU
NC
H
TE
ST
F
AC
IL
IT
Y N
A
N E
C R
A N
E
I N
D I A
N A
N40085-19-R-9186
1629197
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
R F
P
P
H A
U B
M I S
S I O
N
RDS/PJB
EJA
C I V
I T
E
M I D
L A
C
O R
E N
A V
A L
S
T A
T I O
N
N
O R
F O
L K
V
A
2/24/2020
APPROVED BY SHANE A. FRINK
CTF TEST SYSTEM INTEGRATOR
NSWC CRANE VIA EMAIL
DLB
C O
N S
T R
U C
T I O
N
D
E T
A I L
S
UTF-C-512
12810642
AS NOTED
KM MD JK
L
'D' DIA.
HOLE
27"
'W'
18"
12"
'C'
'B'
'A'
'H'
HDPE 'D' 'A' 'B' 'C' 'H' 'L' 'W'
12" 21" 30" 32" 12" 74" 48" 108"
15" 24" 30" 32" 12" 74" 48" 108"
18" 27" 30" 32" 12" 74" 48" 108"
24" 34" 30" 32" 12" 74" 48" 108"
30" 42" 36" 39" 9" 84" 72" 152"
36" 48" 42" 39" 9" 90" 72" 152"
42" 54" 42" 36" 12" 90" 96"…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .