CBD DRAWINGS-FINAL.pdf
PDF 16 MB Posted
- Solicitation number
- N4008020R0007
About this file
This document package includes construction drawings and a federal contract opportunity. The construction drawings depict the demolition of above ground storage tanks and pump houses at the Chesapeake Beach Detachment in Maryland. Key details include sawcutting joints between existing and demolition concrete, maintaining access, installing per manufacturer specifications, and restoring disturbed ground with sod.
The related federal contract opportunity is a multiple award indefinite delivery indefinite quantity construction contract for new construction, repair, and renovation projects at various facilities within the Naval Facilities Engineering Command Washington area of responsibility, including Washington D.C., Maryland and Virginia. Design-build and design-bid-build projects are included. The estimated value is $49M over five years. The solicitation number is N4008020R0007 and was issued by the Department of the Navy Naval Facilities Engineering Command. The response due date is not provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMENDMENT 0006.pdf | ||
| Site Visit Sheet-13JAN2020.pdf | ||
| AMEND 0005-ATTACH #1-Masonry and Paint Spec - Div 04 and 09.pdf | ||
| AMEND 0005-ATTACH#3-Revised Price Schedule dated 9 January 2020.docx | DOCX document | |
| AMEND 0005-ATTACH #2-Seeding Specification.pdf | ||
| AMENDMENT 0005.pdf | ||
| AMENDMENT 0004.pdf | ||
| AMENDMENT 0003.pdf | ||
| 17 December Site Visit Attendance Sheet.pdf | ||
| Revised Past Performance Questionnaire.docx | DOCX document | |
| PC170005.jpg | JPG image | |
| PC170001.jpg | JPG image | |
| HUBZONE MACC AMENDMENT 0002.pdf | ||
| PC170007.jpg | JPG image | |
| PC170006.jpg | JPG image | |
| PC170004.jpg | JPG image | |
| PC170002.jpg | JPG image | |
| PC170003.jpg | JPG image | |
| AMENDMENT 0001.pdf | ||
| CBD Price Schedule dated 3 December 2019.docx | DOCX document | |
| CBD CATEX.pdf | ||
| Past Performance Questionnaire.docx | DOCX document | |
| CBD Basis of Design Final.pdf | ||
| CBD SPECS - FINAL.pdf | ||
| NRL SECNAV_5512-1.pdf | ||
| CONSTRUCTION EXPERIENCE PROJECT DATA SHEET.docx | DOCX document | |
| SOLICITATION N4008020R0007 HUBZONE MACC.pdf |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
A
1 2 3 4
DEMO ABOVE GROUND STORAGE TANKS AND PUMP HOUSES
lEGEND
CD SHEET NOTE
� EXTERIOR ELEVATION MARK
@---- ___j SECTION MARK
I
I DETAIUENLARGED PLAN BUBBLE
I I
L _ _J
FIRST LEVEL FIN. FL.
0'-0" BENCHMARK
SF
ROOMNAME
IRM#I
EW-
LOO-
FINISH FLOOR REFERENCE
NORTH ARROW
REVISION CLOUD REFERENCE
BREAK LINE
SILT FENCE
CONTOUR LINE
ROOM REFERENCE
PHOTO REFERENCE
EXISTING WATER LINE
LIMIT OF DISTURBANCE
CHESAPEAKE BEACH DETACHMENT
GENERAl NOTES
1. INFORMATION IN DRAWINGS REGARDING EXISTING CONDITIONS HAS BEEN
OBTAINED FROM AVAILABLE BUILDING DRAWINGS AND/OR GENERAL FIELD
OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING CONDITIONS IN
DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING
THE ACTUAL EXISTING CONDITIONS INCLUDING LOCATION OF EXISTING
UTILITIES WITH GROUND PENETRATING RADAR TO PHYSICALLY VERIFY THE
LOCATION AND ELEVATION OF THE EXISTING UTILITIES AND MARK THE SURFACE
OF THE GROUND WHERE EXISTING UNDERGROUND UTILITIES ARE DISCOVERED
PRIOR TO PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE DISCOVERED
THAT PREVENT EXECUTION OF THE NEW WORK AS INDICATED, THE CONTRACT
OFFICER SHALL IMMEDIATELY BE NOTIFIED IN WRITING AND AWAIT DIRECTION
BEFORE PROCEEDING WITH THE WORK.
2. SOIL POTENTIALLY CONTAINS POL (PETROLEUM OIL LUBRICANTS) AND
CHEMICALS ASSOCIATED WITH THE FIRE SUPPRESSANT AFFF TO INCLUDE PFAS.
INCLUDE IN ACTIVITY HAZARD ANALYSIS AND ACCIDENT PREVENTION PLAN. NO
SOILS ARE TO BE TAKEN OFF-SITE.
CONTRACTOR TO MAKE ACCOMMODATIONS TO AVOID SKIN CONTACT WITH
SOIL, ESPECIALLY WHEN MIXED WITH WATER. WHEN WORK IS FINISHED, RINSE
OFF EQUIPMENT AND ANY APPLICABLE PPE TO AVOID EXPOSURE.
3. THE CONTRACTOR SHALL COORDINATE ALL WORK SHOWN IN THE CONTRACT
DOCUMENT SET. THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF
CONTRACT DOCUMENTS TO ALL SUBCONTRACTORS AND RELATED PARTIES.
4. CONTRACTOR SHALL PROVIDE SAFETY FENCING AROUND ASPECTS OF WORK TO
MAINTAIN A SAFE WORK SITE.
5. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN FINAL PROPOSED
CONDITION, AND PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS TO
PROTECT THE PROJECT SITE FROM EROSION, PONDING WATER, AND FLOODING.
6. DISPOSE OF ALL RUBBISH OFFSITE.
7. THE CONTRACTOR IS NOT TO TAKE ANY PHOTOGRAPHS. ONLY NRL OR NAVFAC
EMPLOYEES WITH A CAMERA PASS MAY TAKE PHOTOS.
8. ANY DAMAGE OR RUTTING TO THE GROUND MUST BE REPAIRED. ANY GROUND
DISTURBED AREAS MUST BE RESTORED WITH SOD. RESTORE ALL OTHER AREAS
WITHIN LIMITS OF DISTURBANCE TO ORIGINAL SITE CONDITIONS. ALL BARE SOIL
AT THE CONCLUSION OF WORK MUST BE PROVIDED SOD
9. ALL EXISTING UTILITIES MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO
CONSTRUCTION, AND MARKED. CONTRACTOR TO CONTACT CONSTRUCTION
MANAGER IMMEDIATELY IF ANY DAMAGE OCCURS TO EXISTING UTILITIES.
10. THE LOCATION(S) OF THE CONTRACTOR'S MATERIAL LAYDOWN, STORAGE, AND
STAGING AREA(S) MUST BE COODINATED WITH THE CONTRACTING OFFICER.
11. SAWCUT ALL JOINTS BETWEEN EXISTING CONCRETE TO REMAIN AND CONCRETE
PROPOSED TO BE DEMOLISHED.
12.MAINTAIN CLEAR, COMPLETE, AND SAFE ACCESS FOR GOVERNMENT
PERSONNEL AND CIVILIANS TO ALL BUILDINGS WITHIN OR ADJACENT TO THE
PROJECT SITE.
13.ALL MATERIALS AND SYSTEMS SHALL BE INSTALLED PER MANUFACTURER'S
SPECIFICATIONS AND ALL CONSTRUCTION SHALL BE OF INDUSTRY STANDARD OR
BETTER.
PEAKE
6114D CHESAPEAKE
BAY ,31 ROAD
(BC302l
VICINITY MAP
SCALE: NOT TO SCALE
lOCATION MAP
SCALE: NOT TO SCALE
olU � CH ES A�EA!<E
BAV �37
ff□-,fo (BC29)
DRAWING INDEX
DRAWING NO. DRAWING DESCRIPTION
G-101 TITLE SHEET
C-101 EXISTING CONDITIONS PLAN
C-102 EXISTING CONDITIONS AND DEMO PLAN FOR FUEL TANK AREA
C-103 EXISTING CONDITIONS AND DEMO PLAN FOR SPRINKLER WASTE WATER TANK AREA
C-104 PROPOSED CONDITIONS PLAN FOR FUEL TANK AREA
C-105 PROPOSED CONDITIONS PLAN FOR SPRINKLER WASTE WATER TANK AREA
C-106 REFERENCE DRAWING FOR CONCRETE STRUCTURES AT FUEL TANK
C-107 REFERENCE DRAWING FOR FUEL TANK ELEVATIONS
A-101 ARCHITECTURAL SITE PLAN
M-101 1000 GALLON DOUBLE WALL GASOLINE TANK
M-102 REFERENCE DRAWING FOR PIPING DESIGN AT FUEL TANKS
M-103 REF DRAWING FOR SPRINKLER TANK MECHANICAL PUMP HOUSE
ES101 SITE ELECTRIC PLAN
ED601 ELECTRICAL RISER DIAGRAM WITH DEMOLITION
E-601 ELECTRICAL RISER DIAGRAM NEW WORK
E-101 ENLARGED ELECTRICAL DIAGRAMS
APPROVED
FORCOMMANDER�VFAC
ACTIVITY
SATlSFACTORYTO DATE
DES DRW
SEAL
Alf.INFO
CHK
PM/DM John Jones
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
" (.) ":l! Cl !" :::, � z � 0 0 <( " z " I- ;, ,; C!) <(a: z w z "'w C, z--I � en i� :::J -u Cl �z
�::i: z ::i:
C!)
z a:w w z
C!)
zw enw
� I- � ...J r-- zw (.) wI
I- ii' "- LL « 0 _J fb I- C z <( "'w > "
0:
� <( �c.. z ::J w "'" �
Cl
I-� w � (!J w <( � a: w
�0(1) � 1-W I (/) (/)
�o ::>I Oc..
a:� (!J ::> w e..
>o
1-0z r5 CD<(
Cl) �o� ��z � w � <( Cl w
III . .
\!:! Cl i1i en en w
I
SCALE N.T.S.
EPROJECT NO.: 1617903
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
13110968
SHEET 1 OF 16
G-101
N/A
I-w w I en w I- I-
DRAWFORM REVISION: 10 MARCH 2009
D
C
B
A john.c.jones Typewritten Text
AND PAVING FABRIC
| G-101 |
| C-101 Existing Conditions (1) |
| C-102 Exist FUEL |
| C-103 Exist WW (1) |
| C-104 Proposed FUEL |
| C-105 PROP Cond WW (1) |
| C-106 Existing Information 1 |
| C-107 EXISTING INFO 2 |
| A-101 |
| M-101 |
| M-102 EXISTING INFO 3 |
| M-103 EXISTING INFO 4 |
| ES101 |
| ED601 |
| E-601 |
| E-101 |
2019-08-07T13:54:45-0400
2019-08-07T13:55:16-0400
2019-08-07T13:55:25-0400
2019-08-07T13:55:29-0400
2019-08-07T13:55:30-0400
2019-08-07T13:55:31-0400
2019-08-07T13:55:32-0400
2019-08-07T13:55:38-0400
2019-08-07T13:55:46-0400
2019-08-07T13:55:51-0400
2019-08-07T13:55:58-0400
2019-08-07T13:56:04-0400
2019-08-07T13:56:09-0400
2019-08-07T13:56:10-0400
2019-08-07T13:56:15-0400
2019-08-07T13:56:22-0400
2019-08-08T10:52:02-0400
2019-08-08T10:52:17-0400
2019-08-08T10:52:18-0400
2019-08-08T10:52:20-0400
2019-08-08T10:52:21-0400
2019-08-08T10:52:22-0400
2019-08-08T10:52:23-0400
2019-08-08T10:52:24-0400
2019-08-08T10:52:26-0400
2019-08-08T10:52:27-0400
2019-08-08T10:52:28-0400
2019-08-08T10:52:29-0400
2019-08-08T10:52:31-0400
2019-08-08T10:52:32-0400
2019-08-08T10:52:33-0400
2019-08-08T10:52:34-0400
2019-08-08T10:52:57-0400
2019-08-08T10:53:32-0400
2019-08-08T10:53:41-0400
2019-08-08T10:53:42-0400
2019-08-08T10:53:49-0400
2019-08-08T10:53:50-0400
2019-08-08T10:53:51-0400
2019-08-08T10:53:58-0400
2019-08-08T10:54:11-0400
2019-08-08T10:54:20-0400
2019-08-08T10:54:27-0400
2019-08-08T10:54:28-0400
2019-08-08T10:54:38-0400
2019-08-08T10:54:43-0400
2019-08-08T10:54:44-0400
2019-08-08T10:54:50-0400
File details come from the government source that posted it. Updated .