IFALLS LPOE_75_ CD DRAWINGS 10 Technology.pdf
PDF 27 MB Posted
- Solicitation number
- 47PF0024R0076
About this file
This file is a detailed technology design document for the International Falls Land Port of Entry project, specifically focusing on telecommunications, security, and audiovisual systems infrastructure. The document provides comprehensive technical specifications for conduit routing, cable installation, wireless access points, security cameras, access control systems, and audiovisual equipment across multiple building areas and levels, including the main building, non-commercial secondary building, and secondary commercial/NII areas.
Key technical requirements include installing conduits and cabling according to National Electric Code and federal laws, maintaining specific cable routing standards (such as using j-hooks every 60" and avoiding splices), and ensuring equipment is mounted at appropriate heights and locations. The design covers various systems like data networks, security cameras, access control, wireless access points, and audiovisual components, with detailed guidelines for installation in different building zones. The document is part of a larger construction project funded under the Infrastructure Investment and Jobs Act, with multiple federal agencies involved including U.S. Customs and Border Protection, USDA, and FDA.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A. ALL DIVISION 27 WORK AND DIVISION 28 ELECTRONIC SECURITY WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE AND FEDERAL LAWS OR ORDINANCES GOVERNING THE PROJECT. IF, IN ANY INSTANCE, THE DRAWINGS AND SPECIFICATIONS ARE IN DIRECT CONFLICT WITH SUCH CODES, LAWS OR ORDINANCES, THE CODE, LAWS AND ORDINANCES SHALL HAVE JURISDICTION AND THE WORK IN
QUESTION SHALL BE INSTALLED ACCORDING TO THE CODES, LAWS AND ORDINANCES.
B. BRING DISCREPANCIES SHOWN ON DIFFERENT DRAWINGS AND BETWEEN DRAWINGS AND SPECIFICATIONS OR BETWEEN
DOCUMENTS AND FIELD CONDITIONS TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
C. COORDINATE DIVISION 27 WORK AND DIVISION 28 ELECTRONIC SECURITY WORK WITH ALL OTHER CONTRACTORS AND OWNER FOR THE LOCATION AND SIZES OF EQUIPMENT AND DEVICES PRIOR TO ROUGH-IN. SHOULD DIVISION 27 WORK AND DIVISION 28 ELECTRONIC SECURITY WORK BE INSTALLED WHICH INTERFERES WITH THE WORK OF OTHER CONTRACTORS
OR OWNER, SUCH WORK SHALL BE CHANGED WITH NO ADDITIONAL COST TO OWNER.
D. MOUNT EQUIPMENT AND DEVICES AT NOMINAL MOUNTING HEIGHT INDICATED IN SYMBOL SCHEDULE UNLESS NOTED OTHERWISE ON THE DRAWINGS OR DETAILED IN ARCHITECTURAL ELEVATIONS. DIMENSION SHOWN IS TO CENTER LINE OF BOX UNLESS OTHERWISE NOTED. SEE ARCHITECTURAL INTERIOR AND EXTERIOR ELEVATIONS FOR EXACT LOCATION OF
WALL MOUNTED DEVICES.
E. DEVICES AND EQUIPMENT SHALL BE INSTALLED TO COMPLY WITH ADA STANDARDS FOR ACCESSIBLE DESIGN.
F. CEILING MOUNTED DEVICE LOCATIONS ARE SCHEMATIC; CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH OTHER TRADES - REFER TO ARCHITECTURAL REFLECTED CEILING PLANS. WHERE PRACTICAL, ALIGN AND CENTER DEVICES WITH
OTHER TRADES (SUCH AS LIGHT FIXTURES).
G. WALL MOUNTED DEVICES IN ADJACENT ROOMS THAT SHARE A WALL SHALL BE INSTALLED IN OFFSETTING STUD CAVITIES.
H. CABLING ROUTED ABOVE ACCESSIBLE CEILINGS SHALL BE INSTALLED IN CONDUIT, IN CABLE TRAY, OR SUPPORTED VIA J- HOOKS EVERY 60” OR LESS AND AT EVERY CHANGE IN DIRECTION. CONDUITS AND J-HOOKS SHALL BE DEDICATED TO STRUCTURED CABLING AND NOT SHARED WITH OTHER LOW-VOLTAGE TRADES UNLESS EXPLICITLY NOTED.
I. CABLING ROUTED ABOVE INACCESSIBLE CEILINGS AND OPEN-TO-STRUCTURE AREAS (SUCH AS MECHANICAL ROOMS) SHALL BE INSTALLED IN CONDUIT; COORDINATE SIZE AND ROUTING WITH DIVISION 270528 CONTRACTOR. REFER TO DIVISION 27 SPECIFICATIONS FOR ADDITIONAL COORDINATION AND SHOP DRAWING REQUIREMENTS.
J. CABLING SHALL BE RATED FOR THE LOCATION IT IS INSTALLED – PLENUM-RATED IN RETURN AIR PLENUM SPACES AND OUTDOOR/WET-RATED FOR WET LOCATIONS (CONDUIT PATHWAYS BELOW OR IN SLAB-ON-GRADE CONCRETE FLOORS).
K. HORIZONTAL DATA CABLING FROM THE SERVING TELECOM ROOM TO VIDEO SURVEILLANCE CAMERAS, DOOR ENTRY INTERCOM STATIONS, AND SELECT AUDIOVISUAL DEVICES SHALL BE PROVIDED BY THE DIVISION 271000 CONTRACTOR.
REFER TO SECURITY AND AUDIOVISUAL DRAWINGS FOR LOCATIONS AND CABLING REQUIREMENTS.
L. SELECT VOICE AND DATA PATCH CABLES AND STATION CABLES SHALL BE FURNISHED BY THE DIVISION 271000 CONTRACTOR TO OTHER CONTRACTORS AND TO THE OWNER FOR INSTALLATION. REFER TO SECTION 271000 FOR PATCH
AND STATION CABLE REQUIREMENTS.
M. FOR VOICE AND DATA OUTLETS, PROVIDE 10 FEET SERVICE LOOP ON J-HOOK IN ACCESS FLOORING BELOW
OUTLET/DEVICE, UNLESS NOTED OTHERWISE.
N. CABLING SHALL BE CONTINUOUS WITHOUT SPLICES AND KINKS. CABLES DAMAGED BEFORE OR DURING INSTALLATION AND THOSE WITH MORE THAN 5 FEET OF PAINT SHALL BE REPLACED WITHOUT ADDITIONAL COST TO THE OWNER.
O. CONTRACTOR SHALL CONCEAL ALL CONDUITS ABOVE SUSPENDED CEILINGS AND BEHIND WALLS, AND ABOVE THE CLT DECK AS INDICATED BY ARCHITECTURAL FLOOR AND ROOF TYPES, SURFACE-MOUNTED CONDUIT IS ONLY ALLOWED IN BACK OF HOUSE OR UNFINISHED LOCATIONS NOTED AS SUCH ON THE ARCHITECTURAL DRAWINGS.
P. IN AREAS WITHOUT CEILINGS, CONDUIT SHALL BE INSTALLED AS UNOBTRUSIVELY AS POSSIBLE, ABOVE THE CLT DECK AS INDICATED BY ARCHITECTURAL FLOOR AND ROOF TYPES, AND PARALLEL AND AT RIGHT ANGLES TO STRUCTURAL
ELEMENTS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS.
Q. IN ALL AREAS WITH EXPOSED CEILINGS, SPECIAL CARE MUST BE TAKEN IN THE INSTALLATION OF CABLE TRAY, CONDUIT, AND OTHER TECHNOLOGY EQUIPMENT. LAYOUTS MUST BE ARRANGED TO COMPLIMENT THE AESTHETICS OF THE SPACE.
REFER ALSO TO ARCHITECTURAL DRAWINGS, SPECIFICATIONS, AND COORDINATION REQUIREMENTS FOR FURTHER
INFORMATION FOR AESTHETIC INTENTS AND PAINTING REQUIREMENTS IN EXPOSED AREAS.
GENERAL TELECHNOLOGY NOTES:
CONDUIT CONCEALED IN WALL OR OVERHEAD.
(#) IS QUANTITY, D" IS DIAMETER IN INCHES.
CONDUIT ROUTED UNDERGROUND OR IN CONCRETE FLOOR SLAB. (#) IS
QUANTITY, D" IS DIAMETER IN INCHES.
CONDUIT TURNING UP
CONDUIT TURNING DOWN
CONDUIT STUBBED OUT
CONDUIT CONTINUATION TICK, FAR END AS NOTED
(#) D" C
(#) D" C
CONDUIT ROUTED EXPOSED OVERHEAD.
(#) IS QUANTITY, D" IS DIAMETER IN INCHES.(#) D" C
PROPOSED J-HOOK CABLE ROUTING ABOVE ACCESSIBLE CEILING
PB OVERHEAD PULLBOX, SIZE PER TABLE ON THIS SHEET (UNO)
HH
HANDHOLE, FLUSH IN GRADE
SIZE IN INCHES (HEIGHT, WIDTH, DEPTH)
H x W x D
MH
MAINTENANCE HOLE
SIZE IN FEET (HEIGHT, WIDTH, DEPTH)
H x W x D
FIRE-RATED PATHWAY DEVICE
REFER TO KEYNOTES FOR SIZES
H x W
WIRE MESH CABLE TRAY
SIZE IN INCHES (HEIGHT, WIDTH)
MOUNTING HEIGHT
J J
A. WIRE MESH CABLE TRAY, CONDUIT PATHWAYS, FIRESTOPPING, PULLBOXES, OUTLET BACKBOXES, JUNCTION BOXES, FLOORBOXES, POKE-THRU DEVICES, FLAT PANEL DISPLAY BACKBOXES, AND OTHER SPECIALTY BOXES SHALL BE PROVIDED PER SECTION 270528 PATHWAYS FOR COMMUNICATIONS AND SHALL BE IN COMPLIANCE WITH TIA-569-E
TELECOMMUNICATIONS PATHWAYS AND SPACES STANDARD.
B. EXTEND CONDUIT FROM DEVICES AND OUTLETS FROM BACKBOX CONTINUOUS TO NEAREST TELECOMMUNICATIONS ROOM OR TO NEAREST ACCESS FLOORING IN THE DIRECTION OF THE SERVING TELECOMMUNICATIONS ROOM, UNLESS
OTHERWISE NOTED.
C. CONDUIT BEND RADIUS: MINIMUM BEND RADIUS OF CONDUITS 2-INCHES IN DIAMETER AND LESS SHALL BE 6 TIMES THE INTERNAL DIAMETER; MINIMUM BEND RADIUS OF CONDUITS GREATER THAN 2-INCHES IN DIAMETER SHALL BE 10 TIMES
THE INTERNAL DIAMETER.
D. PROVIDE ACCESSIBLE PULLBOX BETWEEN EVERY 180 DEGREES OF CONDUIT BENDS AND FOR LONG STRETCHES OF CONDUIT EVERY 100 FEET. SIZE PULLBOXES PER PART 3 OF SECTION 270528. FOR PULLBOXES ABOVE INACCESSIBLE CEILINGS, PROVIDE CEILING ACCESS PANEL; COORDINATE LOCATION WITH OTHER TRADES AND CONFIRM LOCATION
WITH ARCHITECT PRIOR TO INSTALLATION.
E. CONDUIT TERMINATIONS: EXTEND CONDUITS 3-INCHES THROUGH WALL OR FLOOR AND PROVIDE INSULATED BUSHING
ON THE END.
F. INSTALL NYLON PULLSTRING THROUGH EACH CONDUIT WITH 3-FEET OF SLACK AT EACH END.
G. OUTLETS FOR ELEVATORS AND FIRE ALARM CONTROL PANELS SHALL HAVE CONTINUOUS CONDUIT FROM THE OUTLET
TO THE SERVING TELECOMMUNICATIONS ROOM.
H. MAINTAIN FIRE RATING WHERE RACEWAYS, CABLING, DEVICES, ETC. PENETRATE A FIRE RATED STRUCTURE. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATION OF FIRE RATED WALLS AND CEILINGS. PROVIDE UL LISTED FIRESTOPPING SYSTEM AT ALL PENETRATIONS AS REQUIRED; REFER TO SECTION 270528 PATHWAYS FOR
COMMUNICATIONS FOR ADDITIONAL FIRESTOPPING REQUIREMENTS.
I. WHERE J-HOOK CABLE ROUTING ENCOUNTERS A FULL-HEIGHT NON-RATED WALL OR SECTION OF INACCESSIBLE CEILING
LONGER THAN 8 FEET, PROVIDE APPROPRIATELY-SIZED CONDUIT(S) / SLEEVE(S).
J. INDICATE PROPOSED CONDUIT ROUTING / SIZES AND PULLBOX SIZES / LOCATIONS ON PRE-CONSTRUCTION SHOP
DRAWINGS.
K. REFER TO TECHNOLOGY SITE PLAN FOR UNDERGROUND PATHWAY GENERAL NOTES.
CONDUIT SLEEVE(S) THROUGH WALL
CONDUIT ARC INDICATES SCHEMATIC CONNECTION;
INDICATE PROPOSED ROUTING ON PRE-CONSTRUCTION SHOP DRAWINGS.
STRAIGHT CONDUIT SECTIONS INDICATE PROPOSED CONDUIT ROUTING;
INDICATED REVISED/FINAL ROUTING ON PRE-CONSTRUCTION SHOP DRAWINGS.
CONDUIT HOMERUN (CONTINUOUS) TO INDICATED FAR END LOCATION
XX
PATHWAYS & CABLE ROUTING SYMBOLS
PATHWAYS & CABLE ROUTING GENERAL NOTES:
TELCO STYLE CABLE RUNWAY
REFER TO KEYNOTES FOR SIZES
PLAN KEY NOTE. SEE KEY NOTE SCHEDULE ON THAT DRAWING. ARROW POINTS TO THE ITEM TO WHICH THE
NOTE APPLIES.
SEE SYMBOL DESIGNATIONS DETAIL ON SHEET A010 FOR SECTION, ELEVATION, CALLOUT, AND OTHER SYMBOL DESIGNATIONS
GENERAL SYMBOLS:
DASHED SYMBOL INDICATES EXISTING DEVICES TO BE REMOVED.
POWER COORDINATION SYMBOLS
COORDINATE EXACT LOCATION WITH DIVISION 26 CONTRACTOR
WALL-MOUNTED DUPLEX 20A / 120V RECEPTACLE, D INDICATES DEDICATED CIRCUIT
WALL-MOUNTED DOUBLE DUPLEX 20A / 120V RECEPTACLE, D INDICATES DEDICATED CIRCUIT
SPECIAL PURPOSE RECEPTACLE, LABEL INDICATES RECEPTACLE TYPE
CEILING-MOUNTED DUPLEX 20A / 120V RECEPTACLE, D INDICATES DEDICATED CIRCUIT
THE FOLLOWING 75% CONSTRUCTION DOCUMENTS PROGRESS PRINT IS ISSUED FOR THE PURPOSE OF GSA OBTAINING PROPOSALS FROM CONTRACTORS. THE INFORMATION ISSUED MAY NOT BE USED TO PREPARE SHOP DRAWINGS AND ARE NOT
FOR CONSTRUCTION.
THE LEVEL OF DOCUMENTATION, DETAILING, AND ANNOTATION ARE INDICATIVE OF AN IN-PROGRESS CONSTRUCTION DOCUMENT DRAWING SET. SUBSEQUENT DRAWING PACKAGES WILL REFINE THE DRAWING SET TO PROVIDE ADDITIONAL
CLARITY TO THE DESIGN INTENT WHICH MAY IMPACT COST.
75% CONSTRUCTION DOCUMENT PRINT:
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
/2
/2
:3
:4
P
M
T0.00
TELECOM LEGEND
12/29/22Author
Checker
A
A or AMP AMPERE
AC ALTERNATING CURRENT
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
ALS ASSISTIVE LISTENING SYSTEM
AP ACCESS POINT
AUX AUXILIARY
AV AUDIOVISUAL
AVB AUDIO VIDEO BRIDGING (NETWORK STANDARDS)
AWG AMERICAN WIRE GAUGE
B
BAS BUILDING AUTOMATION SYSTEM
BDA BIDIRECTIONAL AMPLIFIER
BMS BUILDING MANAGEMENT SYSTEM
C
C CONDUIT
CAM CAMERA
CATV CABLE TELEVISION
CLG CEILING
CLT CROSS LAMINATED TIMBER
D
DAS DISTRIBUTED ANTENNA SYSTEM
dB DECIBEL
DC DIRECT CURRENT OR DOOR CONTACT
DIA DIAMETER
DSP DIGITAL SIGNAL PROCESSOR
E
EF ENTRANCE FACILITY (MPOP)
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
EOLR END OF LINE RESISTOR
F
FACP FIRE ALARM CONTROL PANEL
FB FLOOR BOX
FF FURNITURE FEED
FTP FOIL TWISTED PAIR
H
HDBT HDBaseT (AV TRANSMISSION)
HH HANDHOLE
Hz HERTZ
I
I/O INPUT/OUTPUT
IDF INTERMEDIATE DISTRIBUTION FRAME (TELECOM ROOM)
IMC INTERMEDIATE METAL CONDUIT
IP INTERNET PROTOCOL
IR INFRARED
ISP INTERNET SERVICE PROVIDER
K kHz KILOHERTZ
KVA KILOVOLT-AMPERE
KW KILOWATT
L
LAN LOCAL AREA NETWORK
LED LIGHT EMITTING DIODE
M
MDF MAIN DISTRIBUTION FRAME (MAIN TR)
MH MAINTENANCE HOLE
MM MULTIMODE (FIBER)
N
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION AGENCY
NTS NOT TO SCALE
O
OC ON CENTER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFE OWNER FURNISHED EQUIPMENT
OFOI OWNER FURNISHED OWNER INSTALLED
OSP OUTSIDE PLANT CABLE
P
PBB PRIMARY BONDING BUSBAR (TMGB)
PDS PROTECTED DISTRIBUTION SYSTEM
PIR PASSIVE INFRARED
PoE POWER OVER ETHERNET
POS POINT OF SALE
POTS PLAIN OLD TELEPHONE SYSTEM (ANALOG)
PR PAIR
PSI POUNDS PER SQUARE INCH
PTZ PAN TILT ZOOM
PVC POLYVINYL CHLORIDE
R
REX REQUEST TO EXIT
RF RADIO FREQUENCY
RFID RADIO FREQUENCY IDENTIFICATION
RMC RIGID METAL CONDUIT
RTLS REAL TIME LOCATION SYSTEM
RU RACK UNIT
RX RECEIVE/RECEIVER
S
SBB SECONDARY BONDING BUSBAR (TGB)
SM SINGLE MODE (FIBER)
STP SHIELDED TWISTED PAIR
T
TBB TELECOMMUNICATIONS BONDING BACKBONE
TELECOM TELECOMMUNICATIONS
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
TIA TELECOMMUNICATIONS INDUSTRIES ASSOCIATION
TMGB TELECOMMUNICATIONS MAIN GROUNDING BACKBONE
TR TELECOMMUNICATIONS ROOM (IDF)
TX TRANSMITTER
TYP TYPICAL
U
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTP UNSHIELDED TWISTED PAIR
V
V VOLT
VA VOLT-AMPERE
VOIP VOICE OVER INTERNET PROTOCOL
W
W WATT
WAN WIDE AREA NETWORK
WAP WIRELESS ACCESS POINT
WP WEATHER-PROOF
OVERHEAD PULLBOX SIZING
CONDUIT TRADE
SIZE WIDTH LENGTH DEPTH
WIDTH INCREASE FOR
ADDITIONALCONDUITS
1" 4-11/16" 4-11/16" 2-1/8" N/A
1-1/2" 6" 20" 3" 3"
1-1/4" 8" 28" 4" 4"
2" 8" 36" 4" 5"
2-1/2" 10" 42" 5" 6"
3" 12" 48" 5" 6"
4" 16" 60" 8" 6"
DRAWING INDEX - TELECOM
SHEET NUMBER SHEET NAME
T0.00 TELECOM LEGEND
T1.10A TELECOM & SECURITY SITE PLAN - TELECOM AREA A
T1.10B TELECOM & SECURITY SITE PLAN - TELECOM AREA B
T1.10C TELECOM & SECUIRTY SITE PLAN - TELECOM AREA C
T2.M1 LEVEL ONE TELECOM PLAN - MAIN BUILDING OVERALL
T2.M1A LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA A
T2.M1B LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA B
T2.M1C LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA C
T2.M2 LEVEL TWO TELECOM PLAN - MAIN BUILDING OVERALL
T2.M2A LEVEL TWO TELECOM PLAN - MAIN BUILDING AREA A
T2.M2B LEVEL TWO TELECOM PLAN - MAIN BUILDING AREA B
T2.M2C LEVEL TWO TELECOM PLAN - MAIN BUILDING AREA C
T2.N1 LEVEL ONE TELECOM PLAN - NON-COMMERCIAL SECONDARY
T2.N2 LEVEL TWO TELECOM PLAN - NON-COMMERCIAL SECONDARY
T2.S1 LEVEL ONE OVERALL TELECOM PLAN - SECONDARY COMMERCIAL/NII
T2.S1A LEVEL ONE TELECOM PLAN - SECONDARY COMMERCIAL/NII AREA A
T2.S1B LEVEL ONE TELECOM PLAN - SECONDARY COMMERCIAL/NII AREA B
T2.S1C LEVEL ONE TELECOM PLAN - SECONDARY COMMERCIAL/NII AREA C
T2.S2 LEVEL TWO TELECOM PLAN - SECONDARY COMMERCIAL/NII
T2.S2A LEVEL TWO TELECOM PLAN - SECONDARY COMMERCIAL/NII AREA A
T2.S2B LEVEL TWO TELECOM PLAN - SECONDARY COMMERCIAL/NII AREA B
T2.S2C LEVEL TWO TELECOM PLAN - SECONDARY COMMERCIAL/NII AREA C
T3.00 SECURITY LEGEND
T3.M1A LEVEL ONE SECURITY PLAN - MAIN BUILDING AREA A
T3.M1B LEVEL ONE SECURITY PLAN - MAIN BUILDING AREA B
T3.M1C LEVEL ONE SECURITY PLAN - MAIN BUILDING AREA C
T3.M2A LEVEL TWO SECURITY PLAN - MAIN BUILDING AREA A
T3.M2B LEVEL TWO SECURITY PLAN - MAIN BUILDING AREA B
T3.M2C LEVEL TWO SECURITY PLAN - MAIN BUILDING AREA C
T3.N1 LEVEL ONE SECURITY PLAN - NON-COMMERCIAL SECONDARY
T3.N2 LEVEL TWO SECURITY PLAN - NON-COMMERCIAL SECONDARY
T3.S1A LEVEL ONE SECURITY PLAN - SECONDARY COMMERCIAL/NII AREA A
T3.S1B LEVEL ONE SECURITY PLAN - SECONDARY COMMERCIAL/NII AREA B
T3.S1C LEVEL ONE SECURITY PLAN - SECONDARY COMMERCIAL/NII AREA C
T3.S2A LEVEL TWO SECURITY PLAN - SECONDARY COMMERCIAL/NII AREA A
T3.S2B LEVEL TWO SECURITY PLAN - SECONDARY COMMERCIAL/NII AREA B
T3.S2C LEVEL TWO SECURITY PLAN - SECONDARY COMMERCIAL/NII AREA C
T4.00 AUDIOVISUAL LEGEND
T4.M1A LEVEL ONE AUDIOVISUAL PLAN - MAIN BUILDING AREA A
T4.M1B LEVEL ONE AUDIOVISUAL PLAN - MAIN BUILDING AREA B
T4.M1C LEVEL ONE AUDIOVISUAL PLAN - MAIN BUILDING AREA C
T4.M2A LEVEL TWO AUDIOVISUAL PLAN - MAIN BUILDING AREA A
T4.M2B LEVEL TWO AUDIOVISUAL PLAN - MAIN BUILDING AREA B
T4.M2C LEVEL TWO AUDIOVISUAL PLAN - MAIN BUILDING AREA C
T4.N1 LEVEL ONE AUDIOVISUAL PLAN - NON-COMMERCIAL SECONDARY
T4.N2 LEVEL TWO AUDIOVISUAL PLAN - NON-COMMERCIAL SECONDARY
T4.S1A LEVEL ONE AUDIOVISUAL PLAN - SECONDARY COMMERCIAL/NII AREA A
T4.S1B LEVEL ONE AUDIOVISUAL PLAN - SECONDARY COMMERCIAL/NII AREA B
T4.S1C LEVEL ONE AUDIOVISUAL PLAN - SECONDARY COMMERCIAL/NII AREA C
T4.S2A LEVEL TWO AUDIOVISUAL PLAN - SECONDARY COMMERCIAL/NII AREA A
T4.S2B LEVEL TWO AUDIOVISUAL PLAN - SECONDARY COMMERCIAL/NII AREA B
T4.S2C LEVEL TWO AUDIOVISUAL PLAN - SECONDARY COMMERCIAL/NII AREA C
T5.M01 TELECOM ENLARGED PLANS
T5.M02 TELECOM ENLARGED PLANS
T5.M03 TELECOM ENLARGED PLANS
T5.M04 TELECOM ENLARGED PLANS
T5.M05 AUDIOVISUAL ENLARGED PLAN
T5.M06 AUDIOVISUAL ENLARGED PLAN
T5.M07 AUDIOVISUAL ENLARGED PLAN
T5.N01 TELECOM ENLARGED PLANS
T5.S01 TELECOM ENLARGED PLANS
T5.S02 TELECOM ENLARGED PLANS
T6.01 TELECOM ONE-LINE DIAGRAM
T7.01 TELECOM SITE DETAILS
T7.02 TELECOM PATHWAY DETAILS
T7.03 WAP ROUGH-IN DETAIL
T7.04 SECURITY ROUGH-IN DETAIL
T7.05 SECURITY ACCESS CONTROL DETAILS
T7.06 SECURITY ACCESS CONTROL RAISED ACCESS FLOOR DETAILS
T7.07 AUDIO VISUAL DETAILS
T7.08 LPR DETAILS 2
Sheet total: 71
SYMBOLS - TELECOM
ATTRIBUTE CABLE TYPE (# INDICATES CABLE QTY) MOUNTING HEIGHT (UNO) DESCRIPTION RACEWAY BACKBOX TRIM RING OPENING ADDITIONAL REQUIREMENTS
WALL OUTLETS/DEVICES
- PER PLANS DATA CABINET - PER PLANS
# # CAT 6A 18" DATA OUTLET (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG
#, TV # CAT 6A & (1) RG-11 60" DATA OUTLET FOR AUDIOVISUAL TELEVISION (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG PROVIDE (1) COAX F-CONNECTOR IN DATA OUTLET.
#, F # CAT 6A - DATA OUTLET FOR SYSTEMS FURNITURE - - BY SYSTEMS FURNITURE INSTALL JACKS IN SYSTEMS FURNITURE INSERTS
WAP (2) CAT 6A 108" DATA OUTLET FOR WIRELESS ACCESS POINT (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG
W (1) CAT 6A VOICE 18" VOICE OUTLET (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG
FF - 18" WALL MOUNT FURNITURE FEED JUNCTION BOX (1) 1-1/4" C 4-11/16" X 4-11/16" X 2-1/8" DOUBLE GANG, SPLIT PROVIDE GROMMETS AND CABLE LOOM
FLOOR OUTLETS/DEVICES
# # CAT 6A FLUSH TO FLOOR DATA OUTLET WITH FLOORBOX (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG
# # CAT 6A FLUSH TO FLOOR DATA OUTLET WITH POKE THRU (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG
CEILING OUTLETS/DEVICES
WAP (2) CAT 6A FLUSH TO CEILING DATA OUTLET FOR WIRELESS ACCESS POINT (1) 1" C 4-11/16" X 4-11/16" X 2-1/8" SINGLE GANG
ABBREVIATIONS
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
MARK DATE DESCRIPTION
A. UNDERGROUND COMMUNICATIONS CONDUITS, MAINTENANCE HOLES, MAINTENANCE HOLE, AND ACCESSORIES SHALL BE PROVIDED PER SECTION 270543 UNDERGROUND PATHWAYS FOR COMMUNICATIONS AND SHALL BE IN COMPLIANCE WITH TIA-758-B CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS INFRASTRUCTURE STANDARD.
B. CONDUIT BEND RADIUS: MINIMUM BEND RADIUS OF CONDUITS 2-INCHES IN DIAMETER AND LESS SHALL BE 6 TIMES THE INTERNAL DIAMETER; MINIMUM BEND RADIUS OF CONDUITS GREATER THAN 2-INCHES IN DIAMETER SHALL BE 10 TIMES
THE INTERNAL DIAMETER.
C. PROVIDE HANDHOLE OR MAINTENANCE HOLE BETWEEN EVERY 180 DEGREES OF CONDUIT BENDS AND FOR LONG STRETCHES OF CONDUIT EVERY 600 FEET. LOCATE HANDHOLES IN GRASS / LANDSCAPING AREAS WHERE PRACTICAL.
D. MINIMUM DEPTH OF COMMUNICATIONS CONDUITS SHALL BE 30-INCHES UNLESS OTHERWISE NOTED OR REQUIRED BY
THE AUTHORITY HAVING JURISDICTION.
E. COORDINATE ROUTING AND DEPTH OF COMMUNICATIONS CONDUITS WITH CIVIL AND OTHER TRADES. MAINTAIN A MINIMUM SEPARATION OF 12-INCHES WITH UNDERGROUND GAS, WATER, OIL, ETC. MAINTAIN A MINIMUM SEPARATION
OF 12-INCHES WITH POWER FOR EARTH AND 3-INCHES WHERE CONCRETE-ENCASED.
F. UNDERGROUND COMMUNICATIONS CONDUITS LOCATED UNDER DRIVEWAYS, PARKING LOTS AND OTHER AREAS SUBJECT TO VEHICULAR TRAFFIC SHALL BE CONCRETE ENCASED RIGID NONMETALLIC DUCT (SCHEDULE 40 OR 80 PVC).
G. CONDUIT TERMINATIONS INSIDE BUILDING: WITHIN 10-FEET OF EXTERIOR WALL, TRANSITION CONDUIT TO GRS FOR CONTINUATION UNDER / INTO BUILDING. WHERE ROUTED THROUGH FOUNDATION WALL, ENCASE IN CONDUIT PER DETAIL ON T700. EXTEND CONDUITS 3-INCHES INTO THE INDICATED IDF ROOM / LAN ROOM / MPOE ROOM / ELECTRIC ROOM / MECHANICAL ROOM. PROVIDE CONDUIT INSULATED BUSHING AND DUCT PLUG FOR EACH CONDUIT.
H. PROVIDE 1200-LBF NYLON PULL CORD THROUGH EACH CONDUIT WITH 8-FEET OF SLACK AT EACH END.
I. CONDUIT ROUTING AND MAINTENANCE HOLE / MANHOLE LOCATIONS ON THIS DRAWING ARE SCHEMATIC. AFTER COORDINATION WITH OTHER TRADES, INDICATE PROPOSED CONDUIT ROUTING AND HANDHOLE / MAINTENANCE HOLE
LOCATIONS ON PRE-CONSTRUCTION SHOP DRAWINGS.
GENERAL NOTES - SITE PLAN
CMH-2
CMH-1
CHH-1
T1.10B
T1.10A
AREA A
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:3
:4
P
M
T1.10A
TELECOM & SECURITY SITE PLAN - TELECOM AREA A
05/21/2025M. Gundershaug
Checker
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
# DESCRIPTION
1" = 40'-0"
- TELECOM SITE PLAN - TELECOM AREA A
BE PROVIDED PER SECTION 270543 UNDERGROUND PATHWAYS FOR COMMUNICATIONS AND SHALL BE IN COMPLIANCE WITH TIA-758-B CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS INFRASTRUCTURE STANDARD.
B. CONDUIT BEND RADIUS: MINIMUM BEND RADIUS OF CONDUITS 2-INCHES IN DIAMETER AND LESS SHALL BE 6 TIMES THE INTERNAL DIAMETER; MINIMUM BEND RADIUS OF CONDUITS GREATER THAN 2-INCHES IN DIAMETER SHALL BE 10 TIMES
THE INTERNAL DIAMETER.
C. PROVIDE HANDHOLE OR MAINTENANCE HOLE BETWEEN EVERY 180 DEGREES OF CONDUIT BENDS AND FOR LONG STRETCHES OF CONDUIT EVERY 600 FEET. LOCATE HANDHOLES IN GRASS / LANDSCAPING AREAS WHERE PRACTICAL.
D. MINIMUM DEPTH OF COMMUNICATIONS CONDUITS SHALL BE 30-INCHES UNLESS OTHERWISE NOTED OR REQUIRED BY
THE AUTHORITY HAVING JURISDICTION.
E. COORDINATE ROUTING AND DEPTH OF COMMUNICATIONS CONDUITS WITH CIVIL AND OTHER TRADES. MAINTAIN A MINIMUM SEPARATION OF 12-INCHES WITH UNDERGROUND GAS, WATER, OIL, ETC. MAINTAIN A MINIMUM SEPARATION
OF 12-INCHES WITH POWER FOR EARTH AND 3-INCHES WHERE CONCRETE-ENCASED.
F. UNDERGROUND COMMUNICATIONS CONDUITS LOCATED UNDER DRIVEWAYS, PARKING LOTS AND OTHER AREAS SUBJECT TO VEHICULAR TRAFFIC SHALL BE CONCRETE ENCASED RIGID NONMETALLIC DUCT (SCHEDULE 40 OR 80 PVC).
G. CONDUIT TERMINATIONS INSIDE BUILDING: WITHIN 10-FEET OF EXTERIOR WALL, TRANSITION CONDUIT TO GRS FOR CONTINUATION UNDER / INTO BUILDING. WHERE ROUTED THROUGH FOUNDATION WALL, ENCASE IN CONDUIT PER DETAIL ON T700. EXTEND CONDUITS 3-INCHES INTO THE INDICATED IDF ROOM / LAN ROOM / MPOE ROOM / ELECTRIC ROOM / MECHANICAL ROOM. PROVIDE CONDUIT INSULATED BUSHING AND DUCT PLUG FOR EACH CONDUIT.
H. PROVIDE 1200-LBF NYLON PULL CORD THROUGH EACH CONDUIT WITH 8-FEET OF SLACK AT EACH END.
I. CONDUIT ROUTING AND MAINTENANCE HOLE / MANHOLE LOCATIONS ON THIS DRAWING ARE SCHEMATIC. AFTER COORDINATION WITH OTHER TRADES, INDICATE PROPOSED CONDUIT ROUTING AND HANDHOLE / MAINTENANCE HOLE
LOCATIONS ON PRE-CONSTRUCTION SHOP DRAWINGS.
GENERAL NOTES - SITE PLAN
T1.10B
T1.10A
T 1.
C
T 1.
B
BUILDING M
BUILDING N
T7
T4 T10
T11
T12
T0
T5
T61
T8
T99
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1TYPE 1
TYPE 1
TYPE 1 TYPE 1 TYPE 1
TYPE 1
CMH-3
CMH-4
CMH-5
EMERGENCY CALL BOX
PROVIDE ONE (1) 1.25" CONDUIT
AND ONE 4-STRAND OSP RATED
SM FIBER OPTIC CABLE TO
EMERGENCY PHONE LOCATION.
COORDINATE EXACT LOCATION
WITH ELECTRICAL.
PROVIDE 1-1/4" SCH. 40 PVC FROM
CMH (01) TO CAMERA MOUNTED
TO WALL. ROUTE TO M-170
CHH (01)
PROVIDE 1-1/4" SCH. 40 PVC FROM
CMH (01) TO SECUIRTY CAMERA
MOUNTED TO WALL. ROUTE TO
M-170.
PROVIDE 1.1/4" SCH. 40 PVC
CONDUIT FROM CMH-3 TO
CAMERA MOUNTED TO LIGHT
POLES.
PROVIDE 1.1/4" SCH. 40 PVC
CONDUIT FROM CMH-3 TO
CAMERA MOUNTED TO LIGHT
POLES.
CHH (02)
PROVIDE 2" SCH. 40 CONDUIT
FROM CMH (02) TO SEC. CAMERA
J-BOX. ROUTE TO M-170.
PROVIDE 2" SCH. 40 CONDUIT
FROM CMH (02) TO SEC. CAMERA
J-BOX. ROUTE TO M-170.
T3 T2T60
CMH-6
PROVIDE TWO (2) 4" PVC
CONDUITS FROM CMH-01 TO
R00M M-170.
AREA B
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:3
:5
P
M
T1.10B
TELECOM & SECURITY SITE PLAN - TELECOM AREA B
11/03/11Author
Checker
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
# DESCRIPTION
T0 PROVIDE (3) 4" CONDUITS WITH (3) 1-1/4" INNER DUCTS IN EACH CONDUIT TO THE MPOE ROOM FROM COMMUNICATIONS
HANDHOLE FOR INCOMING COMMUNICATIONS SERVICES.
T2 PROVIDE (9) 4 INCH CONDUITS WITH (3) 1-1/4 INCH INNERDUCTS IN EACH CONDUIT FROM BUILDING N TO BUILDING S.
T3 PROVIDE (11) 4 INCH CONDUITS WITH (3) 1-1/4 INCH INNERDUCTS IN EACH CONDUIT FROM BUILDING M TO BUILDING N.
T4 PROVIDE (7) 4 INCH CONDUIT WITH (3) 1-1/4 INCH INNERDUCTS IN EACH CONDUIT FROM CMH-6 TO MAIN DIST ROOM M227
FOR TELECOM BACKBONE CABLING.
T5 PROVIDE (3) 4 INCH CONDUIT WITH (3) 1-1/4 INCH INNERDUCTS FROM MAINTENANCE HOLE TO MPOE ROOM M162 FOR
TELECOM BACKBONE CABLING.
T7 PROVIDE (2) 4 INCH CONDUIT WITH (3) 1-1/4 INCH INNERDUCTS IN EACH CONDUIT FROM CMH-6 TO FIRE ALARM CONTROL
M161 FOR FIRE ALARM CABLING.
T8 PROVIDE (2) 4 INCH CONDUIT WITH (3) 1-1/4 INCH INNERDUCTS IN EACH CONDUIT FROM CMH-6 TO MECH ROOM M171 FOR
BAS CABLING.
T10 PROVIDE (2) 4 INCH CONDUITS WITH (3) 1-1/4 INCH INNERDUCTS FROM CMH-6 TO IDF ROOM N106 FOR TELECOME
BACKBONE CABLING.
T11 PROVIDE (2) 2 INCH CONDUITS FROM MAINTENANCE HOLE TO FIRE ALARM CONTROL ROOM N108 FOR FIRE ALARM
CABLING.
T12 PROVIDE (1) 2 INCH CONDUITS FROM MH TO MECH ROOM N201 FOR BAS CABLING.
T60 PROVIDE 8'x12'x4' COMMUNICATIONS MAINTENANCE HOLE.
T61 PROVIDE 4'x4'x4' COMMUNICATIONS HANDHOLE.
T99 ROUTE SECURITY CAMERAS TO M-170 IDF.
1" = 40'-0"
- TELECOM SITE PLAN - TELECOM AREA B
BE PROVIDED PER SECTION 270543 UNDERGROUND PATHWAYS FOR COMMUNICATIONS AND SHALL BE IN COMPLIANCE WITH TIA-758-B CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS INFRASTRUCTURE STANDARD.
B. CONDUIT BEND RADIUS: MINIMUM BEND RADIUS OF CONDUITS 2-INCHES IN DIAMETER AND LESS SHALL BE 6 TIMES THE INTERNAL DIAMETER; MINIMUM BEND RADIUS OF CONDUITS GREATER THAN 2-INCHES IN DIAMETER SHALL BE 10 TIMES
THE INTERNAL DIAMETER.
C. PROVIDE HANDHOLE OR MAINTENANCE HOLE BETWEEN EVERY 180 DEGREES OF CONDUIT BENDS AND FOR LONG STRETCHES OF CONDUIT EVERY 600 FEET. LOCATE HANDHOLES IN GRASS / LANDSCAPING AREAS WHERE PRACTICAL.
D. MINIMUM DEPTH OF COMMUNICATIONS CONDUITS SHALL BE 30-INCHES UNLESS OTHERWISE NOTED OR REQUIRED BY
THE AUTHORITY HAVING JURISDICTION.
E. COORDINATE ROUTING AND DEPTH OF COMMUNICATIONS CONDUITS WITH CIVIL AND OTHER TRADES. MAINTAIN A MINIMUM SEPARATION OF 12-INCHES WITH UNDERGROUND GAS, WATER, OIL, ETC. MAINTAIN A MINIMUM SEPARATION
OF 12-INCHES WITH POWER FOR EARTH AND 3-INCHES WHERE CONCRETE-ENCASED.
F. UNDERGROUND COMMUNICATIONS CONDUITS LOCATED UNDER DRIVEWAYS, PARKING LOTS AND OTHER AREAS SUBJECT TO VEHICULAR TRAFFIC SHALL BE CONCRETE ENCASED RIGID NONMETALLIC DUCT (SCHEDULE 40 OR 80 PVC).
G. CONDUIT TERMINATIONS INSIDE BUILDING: WITHIN 10-FEET OF EXTERIOR WALL, TRANSITION CONDUIT TO GRS FOR CONTINUATION UNDER / INTO BUILDING. WHERE ROUTED THROUGH FOUNDATION WALL, ENCASE IN CONDUIT PER DETAIL ON T700. EXTEND CONDUITS 3-INCHES INTO THE INDICATED IDF ROOM / LAN ROOM / MPOE ROOM / ELECTRIC ROOM / MECHANICAL ROOM. PROVIDE CONDUIT INSULATED BUSHING AND DUCT PLUG FOR EACH CONDUIT.
H. PROVIDE 1200-LBF NYLON PULL CORD THROUGH EACH CONDUIT WITH 8-FEET OF SLACK AT EACH END.
I. CONDUIT ROUTING AND MAINTENANCE HOLE / MANHOLE LOCATIONS ON THIS DRAWING ARE SCHEMATIC. AFTER COORDINATION WITH OTHER TRADES, INDICATE PROPOSED CONDUIT ROUTING AND HANDHOLE / MAINTENANCE HOLE
LOCATIONS ON PRE-CONSTRUCTION SHOP DRAWINGS.
GENERAL NOTES - SITE PLAN
T 1.
C
T 1.
B
BUILDING S
T1
T13 T15
T17
T16
T18 T14
S12
S12
CMH-7
CHH (03)
PROVIDE 1-1/2" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
EMERGENCY CALL BOX
PROVIDE ONE (1) 1.25"
CONDUIT AND ONE 4-STRAND
OSP RATED SM FIBER OPTIC
CABLE TO EMERGENCY
PHONE LOCATION.
COORDINATE EXACT
LOCATION WITH ELECTRICAL.
PROVIDE TWO (2) 3" SCH. 40
CONDUIT FROM CMH-7 TO SEC.
CAMERA HANDHOLE BACK TO
S-104
PROVIDE 1-1/4" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
PROVIDE 1-1/4" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
PROVIDE 1.1/4" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
PROVIDE 1-1/4" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
PROVIDE 3" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
PROVIDE 1-1/4" SCH. 40 CONDUIT
FROM CMH-7 TO SEC. CAMERA J-
BOX BACK TO S-104
S12
S12
S12
S12
S12
S12
S12
AREA C
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.KEY PLAN - N.T.S.
/2
/2
:4
:0
P
M
T1.10C
TELECOM & SECUIRTY SITE PLAN - TELECOM AREA C
11/03/11Author
Checker
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
# DESCRIPTION
S12 PROVIDE CONDUITS WITH LONG SWEEP ELBOWS FROM LIGHT POLE TO IDF ROOM S104 IN BUILDING S FOR SECURITY CAMERA CABLING. PROVIDE 6-STRAND OUTDOOR RATED POE COMPOSITE FIBER OPTIC CABLE FROM SECURITY CAMERA
TO IDF ROOM S104 IN BUILDING S. NOTE CONDUIT SIZES BY DRAWING.
T1 PROVIDE (7) 4 INCH CONDUITS WITH (3) 1-1/4 INCH INNERDUCTS IN EACH CONDUIT FROM BUILDING S TO BUILDING T.
T13 PROVIDE (4) 4 INCH CONDUITS WITH (3) 1-1/4 INCH INNERDUCTS FROM MAINTENANCE HOLE CMH-7 TO IDF ROOM S104
FOR TELECOM BACKBONE CABLING.
T14 PROVIDE (1) 2 INCH CONDUITS FROM MAINTENANCE HOLE CMH-7 TO MECH ROOM S106 FOR BAS CABLING.
T15 PROVIDE (1) 4 INCH CONDUITS WITH (3) 1-1/4" INNERDUCTS FROM MAINTENANCE HOLE CMH-7 TO USDA IDF ROOM S218
FOR TELECOM BACKBONE CABLING.
T16 PROVIDE (1) 4 INCH CONDUITS WITH (3) 1-1/4" INNERDUCTS FROM MAINTENANCE HOLE CMH-7 TO WALL MOUNTED IDF
EQUIPMENT RACK IN FDA SAMPLE PREP ROOM S206 FOR TELECOM BACKBONE CABLING.
T17 PROVIDE (2) 4 INCH CONDUITS WITH (3) 1-1/4 INCH INNERDUCTS FROM MAINTENANCE HOLE CMH-7 TO IDF ROOM S210
FOR TELECOM BACKBONE CABLING.
T18 PROVIDE (1) 2 INCH CONDUITS FROM MAINTENANCE HOLE CMH-7 IN EACH CONDUIT TO MECH ROOM S213 FOR BAS
CABLING.
1" = 40'-0"
-TELECOM SITE PLAN - TELECOM AREA C
MARK DATE DESCRIPTION
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1
TYPE 1
A. REFER TO COVER SHEET FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. ROUTE HORIZONTAL CABLES FROM DATA OUTLETS TO NEAREST IDF, LAN, OR X ROOM THROUGH RAISED ACCESS
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
1/T2.M1A 1/T2.M1B
1/T2.M1B 1/T2.M1C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
A.1
B.1
C
C.1
D
0.60.50.40.30.2
18"x4"
0' - 10"AFF
18"x4"
0' - 10"AFF
T5.M01
T5.M01
M161
FIRE ALARM
CONTROL
T5.M01
T101
M162
MPOE
M170
IDF
MA MB MC
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:4
:1
P
M
T2.M1
LEVEL ONE TELECOM PLAN - MAIN BUILDING OVERALL
02/22/22MG
MG
KEYNOTES
# DESCRIPTION
T101 ROUTE CABLE TRAY BENEATH RAISED ACCESS FLOOR.
1" = 20'-0"
LEVEL ONE TELECOM PLAN - MAIN BUILDING OVERALL
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
4 4 4
3 3
A. REFER TO COVER SHEET FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. ROUTE HORIZONTAL CABLES FROM DATA OUTLETS TO NEAREST IDF, LAN, OR X ROOM THROUGH RAISED ACCESS
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
1 2
A
B
A.1
B.1
C
C.1
D
0.60.50.40.3 0.2
M111
WATCH
COMMANDERS
M193
POV BOOTH
M194
POV BOOTH
M195
HIGH-LOW
BOOTH
M196
HIGH-LOW
BOOTH
M192
POV BOOTH
M139
POV BOOTH
M166
POV BOOTH
1/T2.M1A 1/T2.M1B
MA
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:4
:1
P
M
T2.M1A
LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA A
02/22/22MG
MG
KEYNOTES
# DESCRIPTION
1/8" = 1'-0"
LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA A
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
3 3
3 3 3
3, F 3, F 3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3, F 3, F
3 3
3 3
TV
TV
A. REFER TO COVER SHEET FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. ROUTE HORIZONTAL CABLES FROM DATA OUTLETS TO NEAREST IDF, LAN, OR X ROOM THROUGH RAISED ACCESS
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
1 2 3 4 5 6 7 8 9 10
A
B
A.1
B.1
C
C.1
D
0.6
2,WAP
2,WAP
2,WAP
108"
108" 108"
M113
BREAK
M112
SUPERVISORS
M111
WATCH
COMMANDERS
M100
VESTIBULE
M121
JANITORIAL
SUPPORT
M114
STAFF RR
M127
AG LAB
M126
AG
SUPERVISOR
M108
VESTIBULE
M105
LACTATION
SUPPORT
M103
PUBLIC
FAMILY/SINGLE
OCC. RR
M152
VIOLATOR
WAITING
M151
IDENT
M190
OUTBOUND
BOOTH
M148
INTERVIEW
M149
INTERVIEW
M150
INTERVIEW
M147
TTRT WAITING
ROOM
M130
AG DISPOSAL
M119
CORRIDOR
MA
STAIR M124
DIGITAL
IMAGING
M104
PUBLIC
FAMILY/SINGLE
OCC. RR
M106
PUBLIC
FAMILY/SINGLE
OCC. RR
M123
SUMP PUMPM129
ELEC CLOSET
M107
PEDESTRIAN /
OUTBOUND
LOBBY
M101
POV /BUS
LOBBY
M102
VESTIBULE
M191
HIGH-LOW
BOOTH
M110
MAIN OFFICER
WORK AREA
M109
CORRIDOR
M134
CORRIDOR
M135
ELEV MA
M101B
DRINKING
FOUNTAIN
M136
SERVICE
VESTIBULE
M192
POV BOOTH
TV TV
72"
72"
TV
TV
2,WAP
2,WAP
2,WAP
2,WAP
1/T2.M2C1/T2.M2B
1/T2.M1A
1/T2.M1B
MB
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:4
:2
P
M
T2.M1B
LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA B
02/22/22Author
Checker
1/8" = 1'-0"
LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA B
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
# DESCRIPTION
3, F
3, F
3, F
3, F
3, F
3, F
3, F
3, F
3 3
3, F
3 3
TVTV
W
W
W
1 W
A. REFER TO COVER SHEET FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. ROUTE HORIZONTAL CABLES FROM DATA OUTLETS TO NEAREST IDF, LAN, OR X ROOM THROUGH RAISED ACCESS
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
T5.M01
T5.M01
10 11 12 13 14 15 16 17 18
A
B
A.1
B.1
C
C.1
D
T5.M01
T100
M169
UPS
M140
VIOLATOR
PERSONAL
PROPERTY
STORAGE
M132
TEMPORARY
SEIZED
PROPERTY
STORAGE
M133
FRAUD/FORENSIC
LAB
M162
MPOE
M184
TRANSFORMER
YARD
M127
AG LAB
M161
FIRE ALARM
CONTROL
M126
AG
SUPERVISOR
M125
AG WORK
AREA
M145
ENFORCEMENT
WORK AREA (2)
M174
TRASH/RECYCLING
M152
VIOLATOR
WAITING
M120
SECURE
CORRIDOR
M146
TTRT
INTERVIEW
M160
PLUMBING
ACCESS
M131
FOOD PREP
M176
ELEC CLOSET
M148
INTERVIEW
M149
INTERVIEW
M128
TECH OFFICE
M164
TTRT
SUPERVISOR
M163
SPECIAL
RESPONSE
TEAM
M171
MECHANICAL
M144
SEARCH
M141
INTERVIEW
M142
INTERVIEWM143
SEARCH
M154
JUV HOLD
M155
HOLD
M156
HOLD
M157
HOLD
M158
HOLD
M153
FAMILY HOLD
M172
CBP STAFF RR
M173
CBP STAFF RR
M147
TTRT WAITING
ROOM
M170
IDF
M167
CONFERENCE/MUSTER
AREA/TRAINING
M168
TRAINING
STORAGE
MB
STAIR
M124
DIGITAL
IMAGING
M159
FIRE/WATER
SERVICE
M165
TTRT
SUPERVISOR
M181
TT INTERVIEW
M180
TT INTERVIEW
M178
PUBLIC
FAMILY/SINGLE
OCC. RR
M179
TT WORK AREA
M177
TT WAITING
M175
VESTIBULE
M182
TT INTERVIEW
M116
CORRIDOR
M117
SERVICE
VESTIBULE
M118
CORRIDOR
M134
CORRIDOR
M135
ELEV MA
2,WAP
2,WAP
2,WAP
2,WAP
2,WAP
2,WAP
M119
CORRIDOR
1/T2.M1B 1/T2.M1C
MC
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:4
:2
P
M
T2.M1C
LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA C
02/22/22Author
Checker
1/8" = 1'-0"
LEVEL ONE TELECOM PLAN - MAIN BUILDING AREA C
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
# DESCRIPTION
T100 PROVIDE WALL MOUNTED IT CABINET.
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
A.1
B.1
C
C.1
D
0.6 0.5
0.40.30.2 19
T5.M02
T5.M02
M253
IDF
M212
HSDN M225
SLAN
M232
IDF
T5.M02
T5.M02
T5.M03
T5.M03
1/T2.M1A 1/T2.M1B
1/T2.M1B 1/T2.M1C
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:4
:3
P
M
T2.M2
LEVEL TWO TELECOM PLAN - MAIN BUILDING OVERALL
02/22/22Author
Checker
1" = 20'-0"
LEVEL TWO TELECOM PLAN - MAIN BUILDING AREA A
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
1 2
A
B
A.1
B.1
C
C.1
D
0.6
0.5
0.40.30.2 19
M251
MECHANICAL
M253
IDF
M254
SERVICE
CORRIDOR
M252
SERVICE
CORRIDOR
1/T2.M1A 1/T2.M1B
MA
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTERNATIONAL FALLS, MN
INTERNATIONAL FALLS LAND PORT OF ENTRY
UNITED STATES LAND PORT OF ENTRY
INTERNATIONAL FALLS, MINNESOTA
SETH LAROCQUE
75% CONSTRUCTION DOCUMENTS
2025.05.23
ENGINEERING
HGA
420 NORTH 5TH STREET, MINNEAPOLIS, MN
(612) 758-4000
LANDSCAPE ARCHITECTURE
TEN X TEN
807 BROADWAY STREET NE, SUITE 221, MINNEAPOLIS, MN 55413
(612) 440-8369
RAIL AND TRAFFIC ENGINEERING
STANTEC
733 MARQUETTE AVENUE, SUITE 1000, MINNEAPOLIS, MN 55402
(612) 712-2000
SUSTAINABILITY
ATELIER TEN
104 WEST 29TH STREET, 8TH FLOOR, NEW YORK, NY 10001
(212) 254-4500
PHYSICAL SECURITY/BLAST DESIGN
INTEGRAL RSG
88 KEARNY STREET, SUITE 875, SAN FRANCISCO, CA 94108
(415) 329-0519
KEY PLAN - N.T.S.
/2
/2
:4
:3
P
M
T2.M2A
LEVEL TWO TELECOM PLAN - MAIN BUILDING AREA A
02/22/22Author
Checker
1/8" = 1'-0"
LEVEL TWO TELECOM PLAN - MAIN BUILDING AREA A
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
KEYNOTES
3 3
3 33 3 3
33 3 3 3 3
TV
W
TV
A. REFER TO COVER SHEET FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. ROUTE HORIZONTAL CABLES FROM DATA OUTLETS TO NEAREST IDF, LAN, OR X ROOM THROUGH RAISED ACCESS
FLOORING.
C. INSTALL WIRELESS ACCESS POINTS (WAP) FLUSH WITH CEILING AND/OR WALL.
D. LEAVE 20 FEET OF EXTRA HORIZONTAL CABLING COILDED ABOE THE CEILING AT EACH WIRELESS ACCESS POINT
OUTLET.
GENERAL NOTES - TECHNOLOGY OVERALL PLAN
1/T2.M2C
1 2 3 4 5 6 7 8 9 10
A
B
A.1
B.1
C
C.1
D
0.6
0.5
1/T2.M2B
T5.M02
T5.M02
M205
CONFERENCE
RM - PORT
DIRECTOR
M221
CHIEF 01
M222
CHIEF 02
M223
CHIEF 03
M213
LAN ADMIN.
M206
AREA PORT
DIRECTOR
M251
MECHANICAL
M207
STAFF BREAK
M212
HSDN
M250
ROOF
TERRACE
M203
DOCUMENT
HANDLING
M202
FILES AND
STORAGE
M204
PORT
DIRECTOR'S
RECEPTION
M209
COMPUTER
TRAINING LAB
MA
STAIR
M220
CORRIDOR
M201
VESTIBULE
M200
2ND LEVEL
WORK AREA
M253
IDF
M252
SERVICE
CORRIDOR
M255
ELEV CONTROL
M208
STAFF RR
M217
STAFF
LACTATION
SUPPORT
72"
72"
2,WAP
2,WAP
2,WAP
1/T2.M2C1/T2.M2B
1/T2.M1A
1/T2.M1B
MB
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
SITE NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
30 X 42
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
CUI
CUI
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
U.S. CUSTOMS AND BORDER PROTECTION
INTERNATIONAL FALLS LAND PORT OF ENTRY
INTERNATIONAL FALLS, MN
SNOW KREILICH ARCHITECTS
HGA, TEN X TEN, STANTEC, ATELIER TEN, INTEGRAL RSG
MN0301IF
INTE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .