CB-OTH-IV_F23038.0(ESD).pdf
PDF 66 KB Posted
- Attached to
- CUTTER BOAT POOLING PROGRAM
- Solicitation number
- HSCG40-15-R-53015
About this file
F23038.0
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A00009.pdf | ||
| A00008.pdf | ||
| CB-OTH-IV_G51012.0.pdf | ||
| 26-CB-OTH-IV_E25042.0.pdf | ||
| 26-CB-OTH-IV_E26030.1.pdf | ||
| A00007.pdf | ||
| OTH-IV_E35010.0.pdf | ||
| CB-OTH-IV_E72012.0.docx.pdf | ||
| CB-OTH-IV_F20001.0.pdf | ||
| CB-OTH-IV_E32021.0(ESD).pdf | ||
| CB-OTH-IV_E25043.0.pdf | ||
| CB-OTH-IV_G51011.0.pdf | ||
| CB-OTH-IV_E72013.0..pdf | ||
| 26-CB-OTH_E35011.0.pdf | ||
| CB-OTH-IV_E71021.0.pdf | ||
| A00006.pdf | ||
| A00005.pdf | ||
| A00004.pdf | ||
| A00003.pdf | ||
| ZIP_FILE.zip | ZIP file | |
| A00002.pdf | ||
| A45425.0.pdf | ||
| B62040.pdf | ||
| A52023_0.pdf | ||
| A55003_D.pdf | ||
| A00001.pdf | ||
| FINAL_SPECIFICATION_FEBRUARY_2015.docx | DOCX document | |
| OMB_LLL.pdf | ||
| GOVT_PROPERTY_REPORT.pdf | ||
| SOLICITATION.doc | DOC document | |
| OMBUDSMAN.doc | DOC document | |
| MIRR.pdf |
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S. COAST GUARD
ASSET COMPUTERIZED MAINTENANCE SYSTEM
CB-OTH-IV
F23038.0
REV’D: 02/19/15
ASSET NUMBER OPERATING ACTIVITY MAINTENANCE ACCOMPLISHED MAINTENANCE DUE
DATE ASSET HOURS DATE ASSET HOURS
MO DAY YEAR MO DAY YEAR
ZULU DATE ZULU TIME
MO DAY YEAR
SERIAL NUMBER TRACKED ITEM – ALL INFORMATION REQUIRED
ITEM NO.
[ ] DUE
CMS CODE ACTION DESCRIPTION CEINUM
F23038 REM/INST RD33(1EE70), MULTI DISPLAY AV-F230-038
SCHEDULED UNSCHEDULED
P A R T
O F F
BARCODE: SERIAL NUMBER:
PART POSITION:
REASON REMOVED: TIME___ TROUBLE___ CANNIBALIZATION___ OTHER___ COMPONENT STATUS: RFI___ NON RFI___
MAN HOURS: MK___.___ DC___.___ EM___.___ ET___.___ GM___.___ BM___.___ FN___.___ SN___.___ OTHER___.___
TECHNICIAN’S
SIGNATURE
TECHNICIAN’S
ID
QUALITY ASSURANCE
SIGNATURE
P A R T
O N
BARCODE: SERIAL NUMBER:
MAN HOURS: MK___.___ DC___.___ EM___.___ ET___.___ GM___.___ BM___.___ FN___.___ SN___.___ OTHER___.___
TECHNICIAN’S
SIGNATURE
TECHNICIAN’S
ID
QUALITY ASSURANCE
SIGNATURE
*ASTERISK INDICATES QA REQUIRED
QA
REMARKS INDICATING THE REASON FOR REMOVAL ARE REQUIRED
REFERENCES:
IF THE COMPONENT BEING REMOVED IS PART OF A MISHAP THEN THE FOLLOWING IS REQUIRED: (1) PART WILL BE REMOVED “NRFI”. (2) THE REASON REMOVED WILL BE MARKED ”OTHER”. (3) THE FIRST WORD IN THE REMARKS WILL BE “MISHAP” FOLLOWED BY THE “MISHAP NUMBER”. (4) WRITE A BRIEF DESCRIPTION DESCRIBING WHAT OCCURRED. (5) ATTACH A COMPLETED COPY OF THIS MPC SIGN-OF SHEET TO THE “NRFI” COMPONENT PRIOR TO BEING SENT TO THE VENDOR.
REVIEWED
BY LOG YN DATA ENTRY
COMPLETED
MK FN
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
DC SN
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
EM OTHER
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
ET
NAME: TECH ID/TH: _______/_____
GM
BM
1 RD33(1EE70), MULTI DISPLAY REMOVE AND INSTALL
REFERENCES:
COMDTINST 9077.1 (series), Equipment Tag-Out Procedure
TOOLS/TEST EQUIPMENT:
NONE
EXPENDABLES:
Display Unit (RD33), P/N: RD33, CAGE: 1EE70, NIIN: 016161486
CONSUMABLES:
Marker, Identification, P/N: PCMB-3, CAGE: 06383, NIIN: 004229673 (If required)
A PRELIMINARY STEPS
1. Ensure that the area is safe for maintenance.
WARNING
OBSERVE SAFETY PRECAUTIONS WHEN WORKING WITH
ELECTRICAL AND ELECTRONIC EQUIPMENT. FAILURE TO
COMPLY EXPOSES PERSONNEL TO THE DANGER OF
ELECTRICAL SHOCK AND PERSONAL INJURY.
2. Identify breakers and/or switches to be tagged out for the following systems:
a. Display unit (RD33), P/N: RD33.
WARNING
ENSURE EQUIPMENT IS PROPERLY TAGGED OUT. FAILURE TO
COMPLY MAY RESULT IN SERIOUS PERSONAL INJURY OR
DEATH.
3. Complete Red Danger Tag(s) IAW COMDTINST 9077.1 (series).
B REMOVE
1. Locate the rear of the display unit (RD33), (Refer to Figure 1).
2. Ensure all cables have been properly labeled using indentification wire, P/N: PCMB-3, before disconnecting, if required.
3. Disconnect from the back of the display unit (RD33):
a. Ground wire.
b. Power cable.
c. NMEA cable, if required.
4. Remove the four self-tapping screws securing the mounting bracket to the console.
5. Slide the display unit (RD33) out of its mounting position.
6. Place the display unit (RD33) away from the working area.
C INSTALL
1. Install the display unit (RD33), P/N: RD33 into the mounting position.
2. Slide the display unit (RD33) into its mounting position.
NOTE: There is no torque value required, do not over tighten.
3. Tighten the mounting bracket into the console using the four self-tapping screws.
4. Connect the following to the back of display unit (RD33):
a. Ground wire.
b. Power cable.
c. NMEA cable, if required.
D FINAL STEPS
1. Remove Red Danger Tag(s) IAW COMDTINST 9077.1 (series).
2. Restore equipment to the normal status.
3. Record maintenance action by completing appropriate sign-off, adding pertinent remarks.
RD33 MULTI DISPLAY REAR VIEW
Figure 1
POWER
CABLE
GROUND
WIRE
NMEA
CONNECTION SELF-
TAPPING
SCREWS
Ground Wire
Self-tapping Screws
NMEA
Connection
Power Cable
File details come from the government source that posted it. Updated .