CB-OTH-IV_E71021.0.pdf
PDF 68 KB Posted
- Attached to
- CUTTER BOAT POOLING PROGRAM
- Solicitation number
- HSCG40-15-R-53015
About this file
E71021.0
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A00009.pdf | ||
| A00008.pdf | ||
| CB-OTH-IV_G51012.0.pdf | ||
| 26-CB-OTH-IV_E25042.0.pdf | ||
| 26-CB-OTH-IV_E26030.1.pdf | ||
| A00007.pdf | ||
| OTH-IV_E35010.0.pdf | ||
| CB-OTH-IV_E72012.0.docx.pdf | ||
| CB-OTH-IV_F20001.0.pdf | ||
| CB-OTH-IV_E32021.0(ESD).pdf | ||
| CB-OTH-IV_F23038.0(ESD).pdf | ||
| CB-OTH-IV_E25043.0.pdf | ||
| CB-OTH-IV_G51011.0.pdf | ||
| CB-OTH-IV_E72013.0..pdf | ||
| 26-CB-OTH_E35011.0.pdf | ||
| A00006.pdf | ||
| A00005.pdf | ||
| A00004.pdf | ||
| A00003.pdf | ||
| ZIP_FILE.zip | ZIP file | |
| A00002.pdf | ||
| A45425.0.pdf | ||
| B62040.pdf | ||
| A52023_0.pdf | ||
| A55003_D.pdf | ||
| A00001.pdf | ||
| FINAL_SPECIFICATION_FEBRUARY_2015.docx | DOCX document | |
| OMB_LLL.pdf | ||
| GOVT_PROPERTY_REPORT.pdf | ||
| SOLICITATION.doc | DOC document | |
| OMBUDSMAN.doc | DOC document | |
| MIRR.pdf |
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S. COAST GUARD
ASSET COMPUTERIZED MAINTENANCE SYSTEM
CB-OTH-IV
E71021.0
REV’D: 02/19/15
ASSET NUMBER OPERATING ACTIVITY MAINTENANCE ACCOMPLISHED MAINTENANCE DUE
DATE ASSET HOURS DATE ASSET HOURS
MO DAY YEAR MO DAY YEAR
ZULU DATE ZULU TIME
MO DAY YEAR
SERIAL NUMBER TRACKED ITEM – ALL INFORMATION REQUIRED
ITEM NO.
[ ] DUE
CMS CODE ACTION DESCRIPTION CEINUM
E71021 REM/INST WPA-112(10402), LOUDHAILER AV-E710-003
SCHEDULED UNSCHEDULED
P A R T
O F F
BARCODE: SERIAL NUMBER:
PART POSITION:
REASON REMOVED: TIME___ TROUBLE___ CANNIBALIZATION___ OTHER___ COMPONENT STATUS: RFI___ NON RFI___
MAN HOURS: MK___.___ DC___.___ EM___.___ ET___.___ GM___.___ BM___.___ FN___.___ SN___.___ OTHER___.___
TECHNICIAN’S
SIGNATURE
TECHNICIAN’S
ID
QUALITY ASSURANCE
SIGNATURE
P A R T
O N
BARCODE: SERIAL NUMBER:
MAN HOURS: MK___.___ DC___.___ EM___.___ ET___.___ GM___.___ BM___.___ FN___.___ SN___.___ OTHER___.___
TECHNICIAN’S
SIGNATURE
TECHNICIAN’S
ID
QUALITY ASSURANCE
SIGNATURE
*ASTERISK INDICATES QA REQUIRED
QA
REMARKS INDICATING THE REASON FOR REMOVAL ARE REQUIRED
REFERENCES:
IF THE COMPONENT BEING REMOVED IS PART OF A MISHAP THEN THE FOLLOWING IS REQUIRED: (1) PART WILL BE REMOVED “NRFI”. (2) THE REASON REMOVED WILL BE MARKED ”OTHER”. (3) THE FIRST WORD IN THE REMARKS WILL BE “MISHAP” FOLLOWED BY THE “MISHAP NUMBER”. (4) WRITE A BRIEF DESCRIPTION DESCRIBING WHAT OCCURRED. (5) ATTACH A COMPLETED COPY OF THIS MPC SIGN-OF SHEET TO THE “NRFI” COMPONENT PRIOR TO BEING SENT TO THE VENDOR.
REVIEWED
BY LOG YN DATA ENTRY
COMPLETED
MK FN
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
DC SN
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
EM OTHER
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
NAME: TECH ID/TH: _______/_____ NAME: TECH ID/TH: _______/_____
ET
NAME: TECH ID/TH: _______/_____
GM
BM
1 WPA-112(10402), LOUDHAILER REMOVE/INSTALL
REFERENCES:
COMDTINST 9077.1 (series) Equipment Tag-Out Procedure
MPC E71021.3
TOOLS/TEST EQUIPMENT:
NONE
EXPENDABLES:
Siren, Electric Motor Operated, P/N: WP-A2, CAGE: 10402, NIIN: 015057621
CONSUMABLES:
NONE
A PRELIMINARY STEPS
1. Ensure that the area is safe for maintenance.
WARNING
OBSERVE SAFETY PRECAUTIONS WHEN WORKING WITH
ELECTRICAL AND ELECTRONIC EQUIPMENT. FAILURE TO
COMPLY EXPOSES PERSONNEL TO THE DANGER OF
ELECTRICAL SHOCK AND PERSONAL INJURY.
2. Identify breakers and/or switches to be tagged out for the following system:
a. Whelen Loudhailer.
WARNING
ENSURE EQUIPMENT IS PROPERLY TAGGED OUT. FAILURE TO
COMPLY MAY RESULT IN SERIOUS PERSONAL INJURY OR
DEATH.
3. Complete Red Danger Tags IAW COMDTINST 9077.1 (series).
B REMOVE
1. Remove electric motor operated siren (loudhailer).
a. Disconnect microphone from the front panel microphone connector, (Refer to Figure 1).
b. Disconnect the multipin connector from the loudhailer amplifier.
c. Remove mounting screws from the flush mount bracket.
d. Remove flush mount bracket from the console.
e. Remove loudhailer mounting screws from the back of the flush mounting bracket.
f. Remove loudhailer from the flush mounting bracket.
2. Install electric motor operated siren, P/N: WP-A2, (loudhailer).
a. Position loudhailer to be installed into the flush mounting bracket.
b. Install loudhailer mounting screws through the back of the flush mounting bracket and into the loudhailer.
NOTE: There is no torque value required, do not over tighten.
(1) Tighten loudhailer mounting screws.
c. Position loudhailer flush mounting bracket into the console.
d. Install mounting screws into the front of the flush mounting bracket.
NOTE: There is no torque value required, do not over tighten.
(2) Tighten mounting screws.
e. Connect multipin connector to the loudhailer amplifier.
f. Connect microphone to the front panel microphone connector.
C FINAL STEPS
1. Remove Red Danger Tags IAW COMDTINST 9077.1 (series).
2. Perform operational check, (Comply with MPC E71021.3).
3. Restore equipment to the normal status.
4. Record maintenance action by completing sign-off, adding pertinent remarks.
LOUDHAILER
Figure 1
Flush Mount Bracket
Loudhailer Mounting Screws
Mounting Screws
Loudhailer
Mounting Screws Front Panel