This document is a technical specification for helical pile design and installation requirements. Helical piles must be designed and manufactured in accordance with the current International Building Code (IBC) adopted by the local jurisdiction, with the manufacturer holding a current ICC-ES ESR report demonstrating compliance with AC358. The supplier is responsible for designing central shaft dimensions and helical bearing plates (number, size, spacing, and thickness) to support specified design loads. Installation torque requirements must be established by the manufacturer, with minimum torque sufficient to achieve required bearing capacity including a safety factor of 2, and maximum torque not exceeding the allowable torsional capacity of the pile shafts. Helical piles must be designed to resist all stresses induced by installation.

The specification requires confirmation of existing conditions and underground obstructions prior to installation, with probing or scanning necessary to locate obstacles and reporting of unforeseen obstructions to the structural engineer. Pile locations cannot be changed without written structural engineer approval. Special inspection must be performed per Section 1705.9 of the 2024 IBC, with the inspector documenting equipment used, pile dimensions, tip elevations, final depth, final installation torque, installation date, pile and installation contractor information, allowable torque values, helix plate configuration, and both ultimate and allowable capacity for each pile as specified by the manufacturer.

View the file

Other files

File Type Posted
250063_ATT 13_Prebid RFI Responses Round 1.pdf PDF
250063_ATT 8_Liquidated Damages.pdf PDF
250063_ATT 4_ODS.pdf PDF
2026 TAFB Mechanical Standard_signed.pdf PDF
2026 TAFB FIRE PROTECTION STANDARD.pdf PDF
SOW Att 04_Automated Casting Cell.pdf PDF
SOW Att 02a_Controlled Area Training.pptx PPTX presentation
250063_ATT 10_Submittal Register.pdf PDF
23 00 00.pdf PDF
08 11 13.pdf PDF
08 33 23.pdf PDF
10 22 13.pdf PDF
10 44 16.pdf PDF
07 21 16.pdf PDF
00 71 00.pdf PDF
01 33 00.pdf PDF
01 50 00.pdf PDF
ufc_3_260_01_2019_c1.pdf PDF
EM_385-1-1.pdf PDF
dafi21-101_afmcsup_afmcgm2023-01.pdf PDF
ufc_3_601_02_2021.pdf PDF
tinkerafbi13-204.pdf PDF
afman32-7003.pdf PDF
afman91-203_oc-alcsup.pdf PDF
afi48-104.pdf PDF
dodio-2000.16v1_afi10-245-o.pdf PDF
007200_Attch7b_Monthly Hazardous Usage Report.pdf PDF
007200_Attch9_EMS Awareness Training.pdf PDF
JOIST SPECIAL INSPECTIONS.xlsx XLSX spreadsheet
250063_ Redline A-502.pdf PDF
HE05IN_Dimension_Drawing.pdf PDF
lrad331965pd_spec.pdf PDF
ELECTRICAL COMBINED.pdf PDF
4500-MUG.pdf PDF
220042 As Built Drawings.pdf PDF
Solicitation - FA813727R0002.pdf PDF
2026 TAFB Electrical Standard - Signed.pdf PDF
SOW Att 02c_Controlled Area Training - Certificate.pdf PDF
250063_ATT 3_RMDF.pdf PDF
23 05 15.pdf PDF
23 09 13.pdf PDF
09 90 00.pdf PDF
26 20 00.pdf PDF
08 51 23.pdf PDF
07 92 00.pdf PDF
07 14 00.pdf PDF
08 71 00.pdf PDF
23 05 93.pdf PDF
07 84 00.pdf PDF
03 01 00.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HELICAL PILES

HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE CURRENT INTERNATIONAL BUILDING CODE (IBC) ADOPTED BY THE LOCAL JURISDICTION.

HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY SUPPLIER.

HELICAL PILE SHALL BE RECONGNIZED BY ICC AND THE MANUFACTURER SHALL HOLD A CURRENT ICC-ES ESR REPORT SHOWING COMPLIANCE WITH AC358 AND CURRENT INTERNATIONAL BUILDING CODE (IBC) ADOPTED BY THE LOCAL JURISDICTION.

DIMENSIONS OF THE CENTRAL SHAFT AND THE NUMBER, SIZE, SPACING AND THICKNESS OF THE HELICAL BEARING PLATES SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS.

MINIMUM AND MAXIMUM INSTALLATION TORQUES SHALL BE SPECIFIED BY THE HELICAL PILE MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY, INCLUDING A SAFETY FACTOR OF 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS.

HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED TO RESIST ALL STRESSES INDUCED BY INSTALLATION.

EXISTING CONDITIONS AND UNDERGROUND OBSTRUCTIONS SHALL BE CONFIRMED BY THE PILE INSTALLER. PROBING OR SCANNING MAY BE NECESSARY TO LOCATE UNDERGROUND OBSTRUCTIONS. REPORT ANY UNFORSEEN OBSTRUCTIONS TO THE STRUCTURAL ENGINEER.

LOCATIONS OF PILES SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER.

SPECIAL INSPECTION OF THE HELICAL PILE INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 1705.9 OF THE 2024 IBC. THE INSPECTOR SHALL RECORD THE FOLLOWING:

A. EQUIPMENT USED.

B. PILE DIMENSIONS.

C. TIP ELEVATIONS.

D. FINAL DEPTH.

E. FINAL INSTALLATION TORQUE.

F. INSTALLATION DATE.

G. PILE MANUFACTURER.

H. INSTALLATION CONTRACTOR.

I. MINIMUM ALLOWABLE INSTALLATION TORQUE.

J. MAXIMUM ALLOWABLE INSTALLATION TORQUE.

K. HELIX PLATE CONFIGURATION OF EACH PILE.

L. ULTIMATE CAPACITY OF EACH PILE AS SPECIFED BY MANUFACTURER.

M. ALLOWABLE CAPACITY OF EACH PILE AS SPECIFIED BY MANUFACTURER

File details come from the government source that posted it. Updated .