07 21 16.pdf

PDF 26 KB Posted

Attached to
WWYK250063 - INSTALL REACT VII FACILITY, B9001, POST V19
Solicitation number
FA813727R0002
Issued by

About this file

This is a technical specification for mineral fiber blanket insulation for construction projects at Tinker Air Force Base, Oklahoma.

The specification establishes requirements for ASTM C665 Type I blanket insulation without membrane coverings, featuring Class A flame spread ratings of 25 or less per ASTM E84 testing. Blankets must achieve R-Values as indicated on project drawings and contain recycled materials, with fiberglass insulation requiring 20 to 25 percent glass cullet complying with ASTM D5359. Asbestos-containing materials are prohibited. The specification mandates 6 mil polyethylene vapor retarders conforming to ASTM D4397 with water vapor permeance of 1 perm or less, along with pressure-sensitive tape rated at one perm or less per ASTM D3833/D3833M. Accessories include manufacturer-recommended adhesives achieving ULE Greenguard certification, corrosion-resistant mechanical fasteners, and corrosion-resistant wire mesh. Installation requirements include blocking at attic vents and heat-producing devices with specific clearances per NFPA 70, 211, 31, and 54; preventing insulation from sandwiching electrical wiring; maintaining continuity and integrity of insulation at joints and corners; stapling vapor retarder flanges at 6-inch intervals; and providing only full-width blankets for snug fitting between framing members. Contractors must provide NIOSH/MSHA-approved dust/mist respirators and protective clothing for installers and submit product data, manufacturer instructions, and documentation of recycled content and reduced VOC materials for government approval.

View the file

Other files

File Type Posted
250063_ATT 14_Prebid RFI Responses Round 2.pdf PDF
250063_ATT 9_SOW.pdf PDF
250063_ATT 6_OPSEC Review Memo.pdf PDF
2020 TAFB Facility Standard.pdf PDF
250063_SOW.pdf PDF
23 09 23.02.pdf PDF
22 00 00.pdf PDF
23 31 13.00 40.pdf PDF
09 67 23.15.pdf PDF
23 03 00.pdf PDF
10 14 00.20.pdf PDF
05 40 00.pdf PDF
23 64 26.pdf PDF
00 72 00.pdf PDF
01 78 00.pdf PDF
01 45 00.00 10.pdf PDF
01 32 16.00 20.pdf PDF
00 80 05.pdf PDF
00 80 00.pdf PDF
ufc_3_535_01_2017_c4.pdf PDF
ufc_3_600_01_2016_c6.pdf PDF
dafi21-101.pdf PDF
ufc_3_260_04_2018.pdf PDF
dafi13-213_tinkerafbsup.pdf PDF
007200_Attch13_AF487.pdf PDF
013300_Attch1_TAFBF3000.pdf PDF
HELICAL PILES NOTES.docx DOCX document
Door_Window_Schedule.xlsx XLSX spreadsheet
PILE SCHEDULE.xlsx XLSX spreadsheet
esvperf_singledual_2023_V2.pdf PDF
esvEH_singledual_2023_V2.pdf PDF
REACT VII SA-01.pdf PDF
lk406gn05t4_spec.pdf PDF
TAFB B9001 VAV Schedule.pdf PDF
ARCH-COMBINED.pdf PDF
Site Visit Meet Up Location.png PNG image
SOW Att 05_SMS Builder Equipment List_v0 2023 0817.xlsx XLSX spreadsheet
250063_ATT 10_Submittal Register.xlsx XLSX spreadsheet
23 08 00.pdf PDF
21 13 13.pdf PDF
23 07 00.pdf PDF
23 36 00.00 40.pdf PDF
23 05 48.00 40.pdf PDF
10 14 00.10.pdf PDF
08 81 00.pdf PDF
28 31 76.pdf PDF
06 41 16.00 10.pdf PDF
01 42 00.pdf PDF
01 33 16.00 10.pdf PDF
HAZMAT Reporting at Tinker AFB FEB 2025.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 07 21 16

MI NERAL FI BER BLANKET I NSULATI ON

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

ASTM I NTERNATI ONAL ( ASTM)

ASTM C665 ( 2017) St andar d Speci f i cat i on f or Mi ner al - Fi ber Bl anket Ther mal I nsul at i on f or Li ght Fr ame Const r uct i on and Manuf act ur ed Housi ng

ASTM C930 ( 2018) St andar d Cl assi f i cat i on of Pot ent i al Heal t h and Saf et y Concer ns Associ at ed wi t h Ther mal I nsul at i on Mat er i al s and Accessor i es

ASTM D3575 ( 2014) Fl exi bl e Cel l ul ar Mat er i al s Made Fr om Ol ef i n Pol ymer s

ASTM D3833/ D3833M ( 1996; R 2011) Wat er Vapor Tr ansmi ssi on of Pr essur e- Sensi t i ve Tapes

ASTM D4397 ( 2016) St andar d Speci f i cat i on f or Pol yet hyl ene Sheet i ng f or Const r uct i on, I ndust r i al , and Agr i cul t ur al Appl i cat i ons

ASTM D5359 ( 2015) St andar d Speci f i cat i on f or Gl ass Cul l et Recover ed f r om Wast e f or Use i n Manuf act ur e of Gl ass Fi ber

ASTM E136 ( 2016) Behavi or of Mat er i al s i n a Ver t i cal Tube Fur nace at 750 Degr ees C

ASTM E84 ( 2018) St andar d Test Met hod f or Sur f ace Bur ni ng Char act er i st i cs of Bui l di ng Materials

ASTM E96/ E96M ( 2016) St andar d Test Met hods f or Wat er Vapor Tr ansmi ssi on of Mat er i al s

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 211 ( 2016) St andar d f or Chi mneys, Fi r epl aces, Vent s, and Sol i d Fuel - Bur ni ng Appl i ances

NFPA 31 ( 2016) St andar d f or t he I nst al l at i on of Oi l - Bur ni ng Equi pment

NFPA 54 ( 2018) Nat i onal Fuel Gas Code

Apr i l 2019 Page 1 SECTI ON 07 21 16

NFPA 70 ( 2017; ERTA 1- 2 2017; TI A 17- 1; TI A 17- 2;

TI A 17- 3; TI A 17- 4; TI A 17- 5; TI A 17- 6;

TI A 17- 7; TI A 17- 8; TI A 17- 9; TI A 17- 10;

TI A 17- 11; TI A 17- 12; TI A 17- 13; TI A

17- 14) Nat i onal El ect r i cal Code

TECHNI CAL ASSOCI ATI ON OF THE PULP AND PAPER I NDUSTRY ( TAPPI )

TAPPI T803 OM ( 2010) Punct ur e Test of Cont ai ner Boar d

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

29 CFR 1910. 134 Respi r at or y Pr ot ect i on

UL ENVI RONMENT ( ULE)

ULE Gr eenguar d UL Gr eenguar d Cer t i f i cat i on Pr ogr am

1. 2 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 03 Pr oduct Dat a

Bl anket I nsul at i on

Si l l Seal er I nsul at i on

Vapor Ret ar der

Pr essur e Sensi t i ve Tape

Accessories

SD- 08 Manuf act ur er ' s I nst r uct i ons

Insulation

SD- 11 Cl oseout Submi t t al s

Recycl ed Cont ent f or I nsul at i on Mat er i al s

Reduce Vol at i l e Or gani c Compounds ( VOC) f or I nsul at i on Mat er i al s

1. 3 DELI VERY, STORAGE, AND HANDLI NG

1. 3. 1 Delivery

Del i ver mat er i al s t o s i t e i n or i gi nal seal ed wr appi ng bear i ng manuf act ur er ' s name and br and desi gnat i on, speci f i cat i on number , t ype, gr ade, R- val ue, and cl ass. St or e and handl e t o pr ot ect f r om damage. Do not al l ow i nsul at i on mat er i al s t o become wet , soi l ed, cr ushed, or cover ed wi t h i ce or snow. Compl y wi t h manuf act ur er ' s r ecommendat i ons f or

Apr i l 2019 Page 2 SECTI ON 07 21 16 handl i ng, st or i ng, and pr ot ect i ng of mat er i al s bef or e and dur i ng installation.

1. 3. 2 Storage

I nspect mat er i al s del i ver ed t o t he s i t e f or damage; unl oad and st or e out of weat her i n manuf act ur er ' s or i gi nal packagi ng. St or e onl y i n dr y l ocat i ons, not subj ect t o open f l ames or spar ks, and easi l y accessi bl e f or i nspect i on and handl i ng.

1. 4 SAFETY PRECAUTI ONS

1. 4. 1 Respirators

Pr ovi de i nst al l er s wi t h dust / mi st r espi r at or s, t r ai ni ng i n t hei r use, and pr ot ect i ve c l ot hi ng, al l appr oved by Nat i onal I nst i t ut e f or Occupat i onal Saf et y and Heal t h ( NI OSH) / Mi ne Saf et y and Heal t h Admi ni st r at i on ( MSHA) i n accor dance wi t h 29 CFR 1910. 134.

1. 4. 2 Ot her Saf et y Concer ns

Consi der ot her saf et y concer ns and measur es as out l i ned i n ASTM C930.

PART 2 PRODUCTS

2. 1 PRODUCT SUSTAI NABI LI TY CRI TERI A

For pr oduct s i n t hi s sect i on, wher e appl i cabl e and t o ext ent al l owed by per f or mance cr i t er i a, pr ovi de and document t he f ol l owi ng:

2. 1. 1 Recycl ed Cont ent f or I nsul at i on Mat er i al s

Pr ovi de i nsul at i on mat er i al s meet i ng t he r ecycl ed cont ent r equi r ement s as st at ed wi t hi n t hi s sect i on and pr ovi de document at i on i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG par agr aph RECYCLED CONTENT.

2. 1. 2 Reduce Vol at i l e Or gani c Compounds ( VOC) f or I nsul at i on Mat er i al s

Pr ovi de i nsul at i on mat er i al s meet i ng t he r educed VOC r equi r ement s as st at ed wi t hi n t hi s sect i on and pr ovi de document at i on i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG par agr aph REDUCE VOLATI LE

ORGANI C COMPOUNDS.

2. 2 BLANKET I NSULATI ON

ASTM C665, Type I , bl anket s wi t hout membr ane cover i ngs ; Cl ass A, membr ane- f aced sur f ace wi t h a f l ame spr ead of 25 or l ess , except a f l ame spr ead r at i ng of 25 or l ess when t est ed i n accor dance wi t h ASTM E84.

2. 2. 1 Ther mal Resi st ance Val ue ( R- VALUE)

The R- Val ue must be as i ndi cat ed on dr awi ngs.

2. 2. 2 Recycl ed Mat er i al s

Pr ovi de Ther mal I nsul at i on cont ai ni ng r ecycl ed mat er i al s t o t he ext ent pr act i cabl e, pr ovi ded t he mat er i al meet s al l ot her r equi r ement s of t hi s sect i on. The mi ni mum r equi r ed r ecycl ed mat er i al s cont ent by wei ght ar e:

Apr i l 2019 Page 3 SECTI ON 07 21 16

Fi ber gl ass: 20 t o 25 per cent gl ass cul l et compl yi ng wi t h ASTM D5359

2. 2. 3 Pr ohi bi t ed Mat er i al s

Do not pr ovi de asbest os- cont ai ni ng mat er i al s.

2. 3 BLOCKING

Wood, met al , unf aced mi ner al f i ber bl anket s i n accor dance wi t h ASTM C665, Type I , or ot her appr oved mat er i al s. Use onl y non- combust i bl e mat er i al s meet i ng t he r equi r ement s of ASTM E136 f or bl ocki ng ar ound chi mneys and heat pr oduci ng devi ces.

2. 4 VAPOR RETARDER

a. 6 mi l t hi ck pol yet hyl ene sheet i ng conf or mi ng t o ASTM D4397 and havi ng a wat er vapor per meance of 1 per m or l ess when t est ed i n accor dance wi t h

ASTM E96/ E96M.

2. 5 PRESSURE SENSI TI VE TAPE

As r ecommended by t he vapor r et ar der manuf act ur er and havi ng a wat er vapor per meance r at i ng of one per m or l ess when t est ed i n accor dance wi t h

ASTM D3833/ D3833M.

2. 6 ACCESSORIES

2. 6. 1 Adhesive

As r ecommended by t he i nsul at i on manuf act ur er .

Adhesi ves must f ol l ow t he manuf act ur er ' s r equi r ement s f or l ow pol l ut ant emi t t i ng mat er i al s i n achi evi ng ULE Gr eenguar d cer t i f i cat i on f or t hei r i nsul at i on pr oduct s.

2. 6. 2 Mechani cal Fast ener s

Cor r osi on r esi st ant f ast ener s as r ecommended by t he i nsul at i on manufacturer.

2. 6. 3 Wi r e Mesh

Cor r osi on r esi st ant and as r ecommended by t he i nsul at i on manuf act ur er .

PART 3 EXECUTI ON

3. 1 EXI STI NG CONDI TI ONS

Bef or e i nst al l i ng i nsul at i on, ensur e t hat ar eas t hat wi l l be i n cont act wi t h t he i nsul at i on ar e dr y and f r ee of pr oj ect i ons whi ch coul d cause voi ds, compr essed i nsul at i on, or punct ur ed vapor r et ar der s. I f moi st ur e or ot her condi t i ons ar e f ound t hat do not al l ow t he wor kmanl i ke i nst al l at i on of t he i nsul at i on, do not pr oceed but not i f y Cont r act i ng Of f i cer of such condi t i ons.

Apr i l 2019 Page 4 SECTI ON 07 21 16

3. 2 PREPARATION

3. 2. 1 Bl ocki ng at At t i c Vent s and Access Door s

Pr i or t o i nst al l at i on of i nsul at i on, i nst al l per manent bl ocki ng t o pr event i nsul at i on f r om sl i ppi ng over , c l oggi ng, or r est r i ct i ng ai r f l ow t hr ough sof f i t vent s at eaves. I nst al l per manent bl ocki ng t o mai nt ai n accessi bi l i t y t o equi pment or cont r ol s t hat r equi r e mai nt enance or adjustment.

3. 2. 2 Bl ocki ng Ar ound Heat Pr oduci ng Devi ces

I nst al l non- combust i bl e bl ocki ng ar ound heat pr oduci ng devi ces t o pr ovi de t he f ol l owi ng cl ear ances:

a. Recessed l i ght i ng f i x t ur es, i ncl udi ng wi r i ng compar t ment s, bal l ast s, and ot her heat pr oduci ng devi ces, unl ess t hese ar e cer t i f i ed by t he manuf act ur er f or i nst al l at i on sur r ounded by i nsul at i on: 3 i nches f r om out si de f ace of f i x t ur es and devi ces or as r equi r ed by NFPA 70 and, i f i nsul at i on i s t o be pl aced above f i xt ur e or devi ce, 24 i nches above fixture.

b. Masonr y chi mneys or masonr y encl osi ng a f l ue: 2 i nches f r om out si de f ace of masonr y. Masonr y chi mneys f or medi um and hi gh heat oper at i ng appl i ances: Mi ni mum cl ear ances r equi r ed by NFPA 211.

c. Vent s and vent connect or s used f or vent i ng t he pr oduct s of combust i on, f l ues, and chi mneys ot her t han masonr y chi mneys: Mi ni mum cl ear ances as r equi r ed by NFPA 211.

d. Gas Fi r ed Appl i ances: Cl ear ances as r equi r ed i n NFPA 54.

e. Oi l Fi r ed Appl i ances: Cl ear ances as r equi r ed i n NFPA 31.

Bl ocki ng ar ound f l ues and chi mneys i s not r equi r ed when i nsul at i on bl anket , i ncl udi ng any at t ached vapor r et ar der , passed ASTM E136, i n addi t i on t o meet i ng al l ot her r equi r ement s st i pul at ed i n Par t 2. Bl ocki ng i s al so not r equi r ed i f t he chi mneys ar e cer t i f i ed by t he manuf act ur er f or use i n cont act wi t h i nsul at i ng mat er i al s.

3. 3 INSTALLATION

3. 3. 1 Insulation

I nst al l and handl e i nsul at i on i n accor dance wi t h manuf act ur er ' s i nst r uct i ons. Keep mat er i al dr y and f r ee of ext r aneous mat er i al s. Any mat er i al s t hat show vi sual evi dence of bi ol ogi cal gr owt h due t o pr esence of moi st ur e must not be i nst al l ed on t he bui l di ng pr oj ect . Ensur e per sonal pr ot ect i ve c l ot hi ng and r espi r at or y equi pment i s used as r equi r ed. Obser ve saf e wor k pr act i ces.

3. 3. 1. 1 El ect r i cal wi r i ng

Do not i nst al l i nsul at i on i n a manner t hat woul d sandwi ch el ect r i cal wi r i ng bet ween t wo l ayer s of i nsul at i on.

3. 3. 1. 2 Cont i nui t y of I nsul at i on

I nst al l bl anket i nsul at i on t o but t t i ght l y agai nst adj oi ni ng bl anket s and

Apr i l 2019 Page 5 SECTI ON 07 21 16 t o st uds, r af t er s, j oi st s, s i l l pl at es, header s and any obst r uct i ons.

Wher e i nsul at i on r equi r ed i s t hi cker t han dept h of j oi st , pr ovi de f ul l wi dt h bl anket s t o cover acr oss t op of j oi st s. Pr ovi de cont i nui t y and i nt egr i t y of i nsul at i on at cor ner s, wal l t o cei l i ng j oi nt s, r oof , and f l oor . Avoi d cr eat i ng t her mal br i dges.

3. 3. 1. 3 I nst al l at i on at Br i dgi ng and Cr oss Br aci ng

I nsul at e at br i dgi ng and cr oss br aci ng by spl i t t i ng bl anket ver t i cal l y at cent er and packi ng one hal f i nt o each openi ng. But t i nsul at i on at br i dgi ng and cr oss br aci ng; f i l l i n br i dged ar ea wi t h l oose or scr ap insulation.

3. 3. 1. 4 I nsul at i on Bl anket wi t h Af f i xed Vapor Ret ar der

Locat e vapor r et ar der as i ndi cat ed. Do not i nst al l bl anket s wi t h af f i xed vapor r et ar der s unl ess so speci f i ed. Unl ess t he i nsul at i on manuf act ur er ' s i nst r uct i ons speci f i cal l y r ecommend not t o st apl e t he f l anges of t he vapor r et ar der f aci ng, st apl e f l anges of vapor r et ar der at 6 i nch i nt er val s f l ush wi t h f ace or set i n t he s i de of t r uss, j oi st , or st ud. Avoi d gaps and bul ges i n i nsul at i on and " f i shmout h" i n vapor r et ar der s. Over l ap bot h f l anges when usi ng f ace met hod. Seal j oi nt s and edges of vapor r et ar der wi t h pr essur e sensi t i ve t ape. St uf f pi eces of i nsul at i on i nt o smal l cr acks bet ween t r usses, j oi st s, st uds and ot her f r ami ng, such as at at t i c access door s, door and wi ndow heads, j ambs, and si l l s , band j oi st s, and header s. Cover t hese i nsul at ed cr acks wi t h vapor r et ar der mat er i al and t ape al l j oi nt s wi t h pr essur e sensi t i ve t ape t o pr ovi de ai r and vapor tightness.

3. 3. 1. 5 Si z i ng of Bl anket s

Pr ovi de onl y f ul l wi dt h bl anket s when i nsul at i ng bet ween t r usses, j oi st s, or st uds. Si ze wi dt h of bl anket s f or a snug f i t wher e t r usses, j oi st s or st uds ar e i r r egul ar l y spaced.

- - End of Sect i on - -

Apr i l 2019 Page 6 SECTI ON 07 21 16