This is a technical specification document for steel doors and frames at Tinker Air Force Base, Oklahoma, effective April 2019 (Section 08 11 13).

The specification establishes requirements for standard steel doors, custom hollow metal doors, insulated steel door systems, sound-rated steel doors, and associated frames and accessories. Standard steel doors must comply with SDI/DOOR A250.8 standards and are classified by duty level: Heavy Duty (Level 2), Extra Heavy Duty (Level 3), and Maximum Duty (Level 4). All doors shall be 1-3/4 inch thick unless otherwise indicated, with exterior doors requiring closed flush top edges sealed to prevent water intrusion. Custom hollow metal doors may be substituted and must comply with NAAMM HMMA HMM standards with all spaces filled with insulation. Insulated steel door systems require polyurethane foam cores with R-factor of 10.0 or higher, galvanized steel face sheets, and must meet SDI/DOOR A250.4 Level C performance requirements. Sound-rated doors must achieve specified Sound Transmission Class ratings. Steel frames must comply with SDI/DOOR A250.8 Level 2 or 4, include welded corners per AWS D1.1/D1.1M standards, and incorporate appropriate anchors for masonry, stud partition, and concrete installations. Fire and smoke doors and frames must comply with NFPA 80 and NFPA 105, bear UL, FM, or WHI labels, and be tested per NFPA 252 or UL 10C. All doors and frames require factory-primed rust-inhibiting finishes; exterior doors require hot-dip zinc-coated steel per ASTM A924/A924M and ASTM A653/A653M with minimum coating weight of 0.4 ounces per square foot. Submittals requiring government approval include shop drawings, product data, and door and frame schedules. Installation must follow SDI/DOOR A250.11 for frames and SDI/DOOR A250.8 for doors, with proper plumbing, alignment, anchoring, and hardware preparation per ANSI/BHMA A156.115.

View the file

Other files

File Type Posted
250063_ATT 13_Prebid RFI Responses Round 1.pdf PDF
250063_ATT 8_Liquidated Damages.pdf PDF
250063_ATT 4_ODS.pdf PDF
2026 TAFB Mechanical Standard_signed.pdf PDF
2026 TAFB FIRE PROTECTION STANDARD.pdf PDF
SOW Att 04_Automated Casting Cell.pdf PDF
SOW Att 02a_Controlled Area Training.pptx PPTX presentation
250063_ATT 10_Submittal Register.pdf PDF
23 00 00.pdf PDF
08 33 23.pdf PDF
10 22 13.pdf PDF
10 44 16.pdf PDF
07 21 16.pdf PDF
00 71 00.pdf PDF
01 33 00.pdf PDF
01 50 00.pdf PDF
ufc_3_260_01_2019_c1.pdf PDF
EM_385-1-1.pdf PDF
dafi21-101_afmcsup_afmcgm2023-01.pdf PDF
ufc_3_601_02_2021.pdf PDF
tinkerafbi13-204.pdf PDF
afman32-7003.pdf PDF
afman91-203_oc-alcsup.pdf PDF
afi48-104.pdf PDF
dodio-2000.16v1_afi10-245-o.pdf PDF
007200_Attch7b_Monthly Hazardous Usage Report.pdf PDF
007200_Attch9_EMS Awareness Training.pdf PDF
JOIST SPECIAL INSPECTIONS.xlsx XLSX spreadsheet
250063_ Redline A-502.pdf PDF
HE05IN_Dimension_Drawing.pdf PDF
lrad331965pd_spec.pdf PDF
ELECTRICAL COMBINED.pdf PDF
4500-MUG.pdf PDF
220042 As Built Drawings.pdf PDF
Site Visit Meet Up Location.png PNG image
SOW Att 05_SMS Builder Equipment List_v0 2023 0817.xlsx XLSX spreadsheet
250063_ATT 10_Submittal Register.xlsx XLSX spreadsheet
23 08 00.pdf PDF
21 13 13.pdf PDF
23 07 00.pdf PDF
23 36 00.00 40.pdf PDF
23 05 48.00 40.pdf PDF
10 14 00.10.pdf PDF
08 81 00.pdf PDF
28 31 76.pdf PDF
06 41 16.00 10.pdf PDF
01 42 00.pdf PDF
01 33 16.00 10.pdf PDF
HAZMAT Reporting at Tinker AFB FEB 2025.pdf PDF
afi91-202_afmcsup.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 08 11 13

STEEL DOORS AND FRAMES

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.

AMERI CAN WELDI NG SOCI ETY ( AWS)

AWS D1. 1/ D1. 1M ( 2015; Er r at a 1 2015; Er r at a 2 2016) St r uct ur al Wel di ng Code - St eel

ASTM I NTERNATI ONAL ( ASTM)

ASTM A653/ A653M ( 2015; E 2016) St andar d Speci f i cat i on f or St eel Sheet , Zi nc- Coat ed ( Gal vani zed) or Zi nc- I r on Al l oy- Coat ed ( Gal vanneal ed) by t he Hot - Di p Pr ocess

ASTM A879/ A879M ( 2012) St andar d Speci f i cat i on f or St eel Sheet , z i nc Coat ed by t he El ect r ol yt i c Pr ocess f or Appl i cat i ons Requi r i ng Desi gnat i on of t he Coat i ng Mass on Each Surface

ASTM A924/ A924M ( 2016a) St andar d Speci f i cat i on f or Gener al Requi r ement s f or St eel Sheet , Met al l i c- Coat ed by t he Hot - Di p Pr ocess

ASTM C578 ( 2016) St andar d Speci f i cat i on f or Ri gi d, Cel l ul ar Pol yst yr ene Ther mal I nsul at i on

ASTM C591 ( 2016) St andar d Speci f i cat i on f or Unf aced Pr ef or med Ri gi d Cel l ul ar Pol y i socyanur at e Ther mal I nsul at i on

ASTM C612 ( 2014) Mi ner al Fi ber Bl ock and Boar d Ther mal I nsul at i on

ASTM D2863 ( 2013) Measur i ng t he Mi ni mum Oxygen Concent r at i on t o Suppor t Candl e- Li ke Combust i on of Pl ast i cs ( Oxygen I ndex)

ASTM E1300 ( 2016) St andar d Pr act i ce f or Det er mi ni ng Load Resi st ance of Gl ass i n Bui l di ngs

ASTM E283 ( 2004; R 2012) Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men

ASTM F2248 ( 2012) St andar d Pr act i ce f or Speci f y i ng an

Apr i l 2019 Page 1 SECTI ON 08 11 13

Equi val ent 3- Second Dur at i on Desi gn Loadi ng f or Bl ast Resi st ant Gl azi ng Fabr i cat ed wi t h Lami nat ed Gl ass

BUI LDERS HARDWARE MANUFACTURERS ASSOCI ATI ON ( BHMA)

ANSI / BHMA A156. 115 ( 2016) Har dwar e Pr epar at i on i n St eel Door s and St eel Fr ames

NATI ONAL ASSOCI ATI ON OF ARCHI TECTURAL METAL MANUFACTURERS ( NAAMM)

NAAMM HMMA HMM ( 1999; R2000) Hol l ow Met al Manual

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 105 ( 2016) St andar d f or I nst al l at i on of Smoke Door Assembl i es and Ot her Openi ng Protectives

NFPA 252 ( 2017) St andar d Met hods of Fi r e Test s of Door Assembl i es

NFPA 80 ( 2016) St andar d f or Fi r e Door s and Ot her Openi ng Pr ot ect i ves

STEEL DOOR I NSTI TUTE ( SDI / DOOR)

SDI / DOOR 111 ( 2009) Recommended Sel ect i on and Usage Gui de f or St andar d St eel Door s, Fr ames and Accessories

SDI / DOOR 113 ( 2001; R2006) St andar d Pr act i ce f or Det er mi ni ng t he St eady St at e Ther mal Tr ansmi t t ance of St eel Door and Fr ame Assemblies

SDI / DOOR A250. 11 ( 2001) Recommended Er ect i on I nst r uct i ons f or St eel Fr ames

SDI / DOOR A250. 3 ( 2007; R 2011) Test Pr ocedur e and Accept ance Cr i t er i a f or Fact or y Appl i ed Fi ni sh Pai nt ed St eel Sur f aces f or St eel Door s and Fr ames

SDI / DOOR A250. 4 ( 2011) Test Pr ocedur e and Accept ance Cr i t er i a f or Physi cal Endur ance f or St eel Door s and Har dwar e Rei nf or ci ng

SDI / DOOR A250. 6 ( 2003; R2009) Recommended Pr act i ce f or Har dwar e Rei nf or ci ng on St andar d St eel Door s and Fr ames

SDI / DOOR A250. 8 ( 2003; R2008) Recommended Speci f i cat i ons f or St andar d St eel Door s and Fr ames

UNDERWRI TERS LABORATORI ES ( UL)

UL 10C ( 2016) UL St andar d f or Saf et y Posi t i ve Pr essur e Fi r e Test s of Door Assembl i es

Apr i l 2019 Page 2 SECTI ON 08 11 13

1. 2 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Door s; G

Fr ames; G

Accessories

Show el evat i ons, const r uct i on det ai l s, met al gages, har dwar e pr ovi s i ons, met hod of gl azi ng, and i nst al l at i on det ai l s.

Schedul e of door s; G

Schedul e of f r ames; G

Submi t door and f r ame l ocat i ons.

SD- 03 Pr oduct Dat a

Door s; G

Fr ames; G

Accessories

Submi t manuf act ur er ' s descr i pt i ve l i t er at ur e f or door s, f r ames, and accessor i es. I ncl ude dat a and det ai l s on door const r uct i on, panel ( i nt er nal ) r ei nf or cement , i nsul at i on, and door edge const r uct i on. When " cust om hol l ow met al door s" ar e pr ovi ded i n l i eu of " st andar d st eel door s, " pr ovi de addi t i onal det ai l s and dat a suf f i c i ent f or compar i son t o SDI / DOOR A250. 8 r equi r ement s.

1. 3 DELI VERY, STORAGE, AND HANDLI NG

Del i ver door s, f r ames, and accessor i es undamaged and wi t h pr ot ect i ve wr appi ngs or packagi ng. St r ap knock- down f r ames i n bundl es. Pr ovi de t empor ar y st eel spr eader s secur el y f ast ened t o t he bot t om of each wel ded f r ame. St or e door s and f r ames on pl at f or ms under cover i n c l ean, dr y, vent i l at ed, and accessi bl e l ocat i ons, wi t h 1/ 4 i nch ai r space bet ween door s. Remove damp or wet packagi ng i mmedi at el y and wi pe af f ect ed sur f aces dr y. Repl ace damaged mat er i al s wi t h new.

PART 2 PRODUCTS

2. 1 STANDARD STEEL DOORS

SDI / DOOR A250. 8, except as speci f i ed ot her wi se. Pr epar e door s t o r ecei ve door har dwar e as speci f i ed i n Sect i on 08 71 00. Under cut wher e i ndi cat ed. Ext er i or door s shal l have t op edge cl osed f l ush and seal ed t o

Apr i l 2019 Page 3 SECTI ON 08 11 13 pr event wat er i nt r usi on. Door s shal l be 1- 3/ 4 i nch t hi ck, unl ess ot her wi se i ndi cat ed. Pr ovi de ext er i or gl azi ng i n accor dance wi t h ASTM F2248 and ASTM E1300.

2. 1. 1 Cl assi f i cat i on - Level , Per f or mance, Model

2. 1. 1. 1 Heavy Dut y Door s

SDI / DOOR A250. 8, Level 2, physi cal per f or mance Level B, Model 1, wi t h cor e const r uct i on as r equi r ed by t he manuf act ur er , of s i ze( s) and desi gn( s) i ndi cat ed. Wher e ver t i cal st i f f ener cor es ar e r equi r ed, t he space bet ween t he st i f f ener s shal l be f i l l ed wi t h mi ner al boar d i nsul at i on. Pr ovi de Level 2 wher e i ndi cat ed.

2. 1. 1. 2 Ext r a Heavy Dut y Door s

SDI / DOOR A250. 8, Level 3, physi cal per f or mance Level A, Model 1 wi t h cor e const r uct i on as r equi r ed by t he manuf act ur er f or i ndi cat ed ext er i or door s, of s i ze( s) and desi gn( s) i ndi cat ed. Wher e ver t i cal st i f f ener cor es ar e r equi r ed, t he space bet ween t he st i f f ener s shal l be f i l l ed wi t h mi ner al boar d i nsul at i on. Pr ovi de Level 3 wher e i ndi cat ed.

2. 1. 1. 3 Maxi mum Dut y Door s

SDI / DOOR A250. 8, Level 4, physi cal per f or mance Level A, Model 1 wi t h cor e const r uct i on as r equi r ed by t he manuf act ur er f or i ndi cat ed ext er i or door s, of s i ze( s) and desi gn( s) i ndi cat ed. Wher e ver t i cal st i f f ener cor es ar e r equi r ed, t he space bet ween t he st i f f ener s shal l be f i l l ed wi t h mi ner al boar d i nsul at i on. Pr ovi de Level 4 wher e i ndi cat ed.

2. 2 CUSTOM HOLLOW METAL DOORS

Pr ovi de cust om hol l ow met al door s wher e nonst andar d st eel door s ar e i ndi cat ed. At t he Cont r act or ' s opt i on, cust om hol l ow met al door s may be pr ovi ded i n l i eu of st andar d st eel door s. Door s i ze( s) , desi gn( s) , mat er i al s, const r uct i on, gages, and f i ni sh shal l be as speci f i ed f or st andar d st eel door s and shal l compl y wi t h t he r equi r ement of NAAMM HMMA HMM. Fi l l al l spaces i n door s wi t h i nsul at i on. Cl ose t op and bot t om edges wi t h st eel channel s not l i ght er t han 16 gage. Cl ose t ops of ext er i or door s f l ush wi t h an addi t i onal channel and seal t o pr event wat er i nt r usi on. Pr epar e door s t o r ecei ve har dwar e speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE. Under cut door s wher e i ndi cat ed. Door s shal l be 1- 3/ 4 i nch t hi ck, unl ess ot her wi se i ndi cat ed.

2. 3 I NSULATED STEEL DOOR SYSTEMS

I nsul at ed st eel door s shal l have a cor e of pol yur et hane f oam and an R f act or of 10. 0 or mor e ( based on a k val ue of 0. 16) ; f ace sheet s, edges, and f r ames of gal vani zed st eel not l i ght er t han 20 gage, 16 gage, and 16 gage r espect i vel y; magnet i c weat her st r i ppi ng; nonr emovabl e- pi n hi nges;

t her mal - br eak al umi num t hr eshol d; and vi nyl door bot t om. Door s and f r ames shal l r ecei ve phosphat e t r eat ment , r ust - i nhi bi t i ve pr i mer , and baked acr yl i c enamel f i ni sh. Door s shal l have been t est ed i n accor dance wi t h SDI / DOOR A250. 4 and shal l have met t he r equi r ement s f or Level C. Pr epar e door s t o r ecei ve speci f i ed har dwar e. Door s shal l be 1- 3/ 4 i nch t hi ck.

2. 4 SOUND RATED STEEL DOORS

Door s shal l have a Sound Tr ansmi ssi on Cl ass ( STC) as i ndi cat ed on t he drawings.

Apr i l 2019 Page 4 SECTI ON 08 11 13

2. 5 ACCESSORIES

2. 5. 1 Shel ves f or Dut ch Door s

SDI / DOOR 111. Fabr i cat e shel ves of st eel not l i ght er t han 16 gage, of t he s i ze i ndi cat ed. Br acket s shal l be st ock t ype f abr i cat ed of t he same met al used t o f abr i cat e shel ves.

2. 5. 2 Louvers

2. 5. 2. 1 I nt er i or Louver s

SDI / DOOR 111, Louver s shal l be st at i onar y s i ght pr oof t ype wher e schedul ed.

Det achabl e mol di ngs on r oom or non secur i t y s i de of door ; on secur i t y s i de of door , mol di ngs t o be i nt egr al par t of l ouver . For m l ouver f r ames of 20 gage st eel and l ouver bl ades of a mi ni mum 24 gage. Si ght pr oof l ouver s t o be i nver t ed " V" bl ade desi gn wi t h mi ni mum 55 per cent net - f r ee opening.

2. 5. 3 Astragals

For pai r s of ext er i or st eel door s whi ch wi l l not have al umi num ast r agal s or r emovabl e mul l i ons, as speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE pr ovi de over l appi ng st eel ast r agal s wi t h t he door s. For i nt er i or pai r s of f i r e r at ed door s, pr ovi de st ai nl ess st eel ast r agal s compl yi ng wi t h NFPA 80 f or f i r e r at ed assembl i es.

2. 5. 4 Moldings

Pr ovi de mol di ngs ar ound gl ass of i nt er i or and ext er i or door s and l ouver s of i nt er i or door s. Pr ovi de nonr emovabl e mol di ngs on out si de of ext er i or door s and on cor r i dor s i de of i nt er i or door s. Ot her mol di ngs may be st at i onar y or r emovabl e. Secur e i nsi de mol di ngs t o st at i onar y mol di ngs, or pr ovi de snap- on mol di ngs. Munt i ns shal l i nt er l ock at i nt er sect i ons and shal l be f i t t ed and wel ded t o st at i onar y mol di ngs.

2. 6 I NSULATI ON CORES

I nsul at ed cor es shal l be of t ype speci f i ed, and pr ovi de an appar ent U- f act or of . 48 i n accor dance wi t h SDI / DOOR 113 and shal l conf or m t o:

a. Ri gi d Cel l ul ar Pol y i socyanur at e Foam: ASTM C591, Type I or I I , f oamed- i n- pl ace or i n boar d f or m, wi t h oxygen i ndex of not l ess t han 22 per cent when t est ed i n accor dance wi t h ASTM D2863; or

b. Ri gi d Pol yst yr ene Foam Boar d: ASTM C578, Type I or I I ; or

c. Mi ner al boar d: ASTM C612, Type I .

2. 7 STANDARD STEEL FRAMES

SDI / DOOR A250. 8, Level 2 or 4, except as ot her wi se speci f i ed. For m f r ames t o s i zes and shapes i ndi cat ed, wi t h wel ded cor ner s. Pr ovi de st eel f r ames f or door s, s i del i ght s, cased openi ngs, and i nt er i or bor r owed l i ght s, unl ess ot her wi se i ndi cat ed.

Apr i l 2019 Page 5 SECTI ON 08 11 13

2. 7. 1 Wel ded Fr ames

Cont i nuousl y wel d f r ame f aces at cor ner j oi nt s. Mechani cal l y i nt er l ock or cont i nuousl y wel d st ops and r abbet s. Gr i nd wel ds smoot h.

Wel d f r ames i n accor dance wi t h t he r ecommended pr act i ce of t he St r uct ur al Wel di ng Code Sect i ons 1 t hr ough 6, AWS D1. 1/ D1. 1M and i n accor dance wi t h t he pr act i ce speci f i ed by t he pr oducer of t he met al bei ng wel ded.

2. 7. 2 St ops and Beads

For m st ops and beads f r om 20 gage st eel . Pr ovi de f or gl azed and ot her openi ngs i n st andar d st eel f r ames. Secur e beads t o f r ames wi t h oval - head, count er sunk Phi l l i ps sel f - t appi ng sheet met al scr ews or conceal ed cl i ps and f ast ener s. Space f ast ener s appr oxi mat el y 12 t o 16 i nch on cent er .

Mi t er mol ded shapes at cor ner s. But t or mi t er squar e or r ect angul ar beads at cor ner s.

2. 7. 3 Cased Openi ngs

Fabr i cat e f r ames f or cased openi ngs of same mat er i al , gage, and assembl y as speci f i ed f or met al door f r ames, except omi t door st ops and pr epar at i on f or har dwar e.

2. 7. 4 Anchors

Pr ovi de anchor s t o secur e t he f r ame t o adj oi ni ng const r uct i on. Pr ovi de st eel anchor s, z i nc- coat ed or pai nt ed wi t h r ust - i nhi bi t i ve pai nt , not l i ght er t han 18 gage.

2. 7. 4. 1 Wal l Anchor s

Pr ovi de at l east t hr ee anchor s f or each j amb. For f r ames whi ch ar e mor e t han 7. 5 f eet i n hei ght , pr ovi de one addi t i onal anchor f or each j amb f or each addi t i onal 2. 5 f eet or f r act i on t her eof .

a. Masonr y: Pr ovi de anchor s of cor r ugat ed or per f or at ed st eel st r aps or 3/ 16 i nch di amet er st eel wi r e, adj ust abl e or T- shaped;

b. St ud par t i t i ons: Wel d or ot her wi se secur el y f ast en anchor s t o backs of f r ames. Desi gn anchor s t o be f ast ened t o c l osed st eel st uds wi t h sheet met al scr ews, and t o open st eel st uds by wi r i ng or wel di ng;

c. Compl et ed openi ngs: Secur e f r ames t o pr evi ousl y pl aced concr et e or masonr y wi t h expansi on bol t s i n accor dance wi t h SDI / DOOR 111;

and

d. Sol i d pl ast er par t i t i ons: Secur e anchor s sol i dl y t o back of f r ames and t i e i nt o t he l at h. Pr ovi de adj ust abl e t op st r ut anchor s on each si de of f r ame f or f ast eni ng t o st r uct ur al member s or cei l i ng const r uct i on above. Si ze and t ype of st r ut anchor s shal l be as r ecommended by t he f r ame manuf act ur er .

2. 7. 4. 2 Fl oor Anchor s

Pr ovi de f l oor anchor s dr i l l ed f or 3/ 8 i nch anchor bol t s at bot t om of each j amb member . Wher e f l oor f i l l occur s, t er mi nat e bot t om of f r ames at t he i ndi cat ed f i ni shed f l oor l evel s and suppor t by adj ust abl e ext ensi on cl i ps

Apr i l 2019 Page 6 SECTI ON 08 11 13 r est i ng on and anchor ed t o t he st r uct ur al s l abs.

2. 8 FI RE AND SMOKE DOORS AND FRAMES

NFPA 80 and NFPA 105 and t hi s speci f i cat i on. The r equi r ement s of NFPA 80 and NFPA 105 shal l t ake pr ecedence over det ai l s i ndi cat ed or speci f i ed.

2. 8. 1 Labels

Fi r e door s and f r ames shal l bear t he l abel of Under wr i t er s Labor at or i es ( UL) , Fact or y Mut ual Engi neer i ng and Resear ch ( FM) , or War nock Her sey I nt er nat i onal ( WHI ) at t est i ng t o t he r at i ng r equi r ed. Test i ng shal l be i n accor dance wi t h NFPA 252 or UL 10C. Label s shal l be met al wi t h r ai sed l et t er s, and shal l bear t he name or f i l e number of t he door and f r ame manuf act ur er . Label s shal l be per manent l y af f i xed at t he f act or y t o f r ames and t o t he hi nge edge of t he door . Door l abel s shal l not be painted.

2. 8. 2 Over si zed Door s

For f i r e door s and f r ames whi ch exceed t he si ze f or whi ch t est i ng and l abel i ng ar e avai l abl e, f ur ni sh cer t i f i cat es st at i ng t hat t he door s and f r ames ar e i dent i cal i n desi gn, mat er i al s, and const r uct i on t o a door whi ch has been t est ed and meet s t he r equi r ement s f or t he c l ass i ndi cat ed.

2. 8. 3 Ast r agal on Fi r e and Smoke Door s

On pai r s of l abel ed f i r e door s, conf or m t o NFPA 80 and UL r equi r ement s.

On smoke cont r ol door s, conf or m t o NFPA 105.

2. 9 WEATHERSTRIPPING

As speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE.

2. 10 HARDWARE PREPARATI ON

Pr ovi de mi ni mum har dwar e r ei nf or ci ng gages as speci f i ed i n SDI / DOOR A250. 6.

Dr i l l and t ap door s and f r ames t o r ecei ve f i ni sh har dwar e. Pr epar e door s and f r ames f or har dwar e i n accor dance wi t h t he appl i cabl e r equi r ement s of SDI / DOOR A250. 8 and SDI / DOOR A250. 6. For addi t i onal r equi r ement s r ef er t o ANSI / BHMA A156. 115. Dr i l l and t ap f or sur f ace- appl i ed har dwar e at t he pr oj ect s i t e. Bui l d addi t i onal r ei nf or ci ng f or sur f ace- appl i ed har dwar e i nt o t he door at t he f act or y. Locat e har dwar e i n accor dance wi t h t he r equi r ement s of SDI / DOOR A250. 8, as appl i cabl e. Punch door f r ames , wi t h t he except i on of f r ames t hat wi l l have weat her st r i ppi ng or gasket i ng, t o r ecei ve t hr ee r ubber door s i l encer s on l ock s i de of s i ngl e door s and one si l encer f or each l eaf at heads of doubl e door s. Set l ock st r i kes out t o pr ovi de cl ear ance f or s i l encer s.

2. 11 FINISHES

2. 11. 1 Fact or y- Pr i med Fi ni sh

Al l sur f aces of door s and f r ames shal l be t hor oughl y c l eaned, chemi cal l y t r eat ed and f act or y pr i med wi t h a r ust i nhi bi t i ng coat i ng as speci f i ed i n

SDI / DOOR A250. 8.

Apr i l 2019 Page 7 SECTI ON 08 11 13

2. 11. 2 Hot - Di p Zi nc- Coat ed and Fact or y- Pr i med Fi ni sh

Fabr i cat e ext er i or door s and f r ames f r om hot di pped zi nc coat ed st eel , al l oyed t ype, t hat compl i es wi t h ASTM A924/ A924Mand ASTM A653/ A653M. The coat i ng wei ght shal l meet or exceed t he mi ni mum r equi r ement s f or coat i ngs havi ng 0. 4 ounces per squar e f oot , t ot al bot h s i des, i . e. , A40. Repai r damaged zi nc- coat ed sur f aces by t he appl i cat i on of z i nc dust pai nt .

Thor oughl y c l ean and chemi cal l y t r eat t o i nsur e maxi mum pai nt adhesi on.

Fact or y pr i me as speci f i ed i n SDI / DOOR A250. 8.

2. 11. 3 El ect r ol yt i c Zi nc- Coat ed Anchor s and Accessor i es

Pr ovi de el ect r ol yt i cal l y deposi t ed z i nc- coat ed st eel i n accor dance wi t h ASTM A879/ A879M, Commer ci al Qual i t y, Coat i ng Cl ass A. Phosphat e t r eat and f act or y pr i me zi nc- coat ed sur f aces as speci f i ed i n SDI / DOOR A250. 8.

2. 12 FABRI CATI ON AND WORKMANSHI P

Fi ni shed door s and f r ames shal l be st r ong and r i gi d, neat i n appear ance, and f r ee f r om def ect s, waves, scr at ches, cut s, dent s, r i dges, hol es, war p, and buckl e. Mol ded member s shal l be c l ean cut , st r ai ght , and t r ue, wi t h j oi nt s coped or mi t er ed, wel l f or med, and i n t r ue al i gnment . Dr ess exposed wel ded and sol der ed j oi nt s smoot h. Desi gn door f r ame sect i ons f or use wi t h t he wal l const r uct i on i ndi cat ed. Cor ner j oi nt s shal l be wel l f or med and i n t r ue al i gnment . Conceal f ast eni ngs wher e pr act i cabl e.

2. 12. 1 Gr out ed Fr ames

For f r ames t o be i nst al l ed i n ext er i or wal l s and t o be f i l l ed wi t h mor t ar or gr out , f i l l t he st ops wi t h st r i ps of r i gi d i nsul at i on t o keep t he gr out out of t he st ops and t o f aci l i t at e i nst al l at i on of st op- appl i ed head and j amb seal s.

2. 13 PROVI SI ONS FOR GLAZI NG

Mat er i al s ar e speci f i ed i n Sect i on 08 81 00, GLAZI NG.

PART 3 EXECUTI ON

3. 1 INSTALLATION

3. 1. 1 Frames

Set f r ames i n accor dance wi t h SDI / DOOR A250. 11. Pl umb, al i gn, and br ace secur el y unt i l per manent anchor s ar e set . Anchor bot t oms of f r ames wi t h expansi on bol t s or powder - act uat ed f ast ener s. Bui l d i n or secur e wal l anchor s t o adj oi ni ng const r uct i on. Backf i l l f r ames wi t h mor t ar . Coat i nsi de of f r ames wi t h cor r osi on- i nhi bi t i ng bi t umi nous mat er i al . For f r ames i n ext er i or wal l s, ensur e t hat st ops ar e f i l l ed wi t h r i gi d i nsul at i on bef or e gr out i s pl aced.

3. 1. 2 Doors

Hang door s i n accor dance wi t h c l ear ances speci f i ed i n SDI / DOOR A250. 8.

Af t er er ect i on and gl azi ng, c l ean and adj ust har dwar e.

3. 1. 3 Fi r e and Smoke Door s and Fr ames

I nst al l f i r e door s and f r ames, i ncl udi ng har dwar e, i n accor dance wi t h

Apr i l 2019 Page 8 SECTI ON 08 11 13

NFPA 80. I nst al l f i r e r at ed smoke door s and f r ames i n accor dance wi t h NFPA 80 and NFPA 105.

3. 2 PROTECTION

Pr ot ect door s and f r ames f r om damage. Repai r damaged door s and f r ames pr i or t o compl et i on and accept ance of t he pr oj ect or r epl ace wi t h new, as di r ect ed. Wi r e br ush r ust ed f r ames unt i l r ust i s r emoved. Cl ean t hor oughl y. Appl y an al l - over coat of r ust - i nhi bi t i ve pai nt of t he same t ype used f or shop coat .

3. 3 CLEANING

Upon compl et i on, c l ean exposed sur f aces of door s and f r ames t hor oughl y.

Remove mast i c smear s and ot her unsi ght l y mar ks.

- - End of Sect i on - -